RSI VIDEOTECHNOLOGIES CT01 Indoor Contact Transmitter User Manual Manual IRT601
RSI VIDEOTECHNOLOGIES Indoor Contact Transmitter Manual IRT601
Contents
Manual_IRT601
INSTALLATION SHEET INDOOR RELAY TRANSMITTER IRT200 IRT601 IRT702 DOC. - REF. 219-IRT MODIF. DATE : NOVEMBER 2016 VERSION : 08.XX.XX Product presentation Installation guidelines The IRT indoor relay transmitter is designed for use with Videofied™ wireless security systems. The contact includes the following features : • Completely wireless and powered by a Lithium battery • Dual tamper function provides detection for both wall and cover tamper • Transmits check-in/status signal every 8 minutes • Programmable radio output for wired devices trigger For easier installation, programming and RF testing should be done to check proper communication between the control panel and all system devices before mounting system devices. Install the detector and other system devices in the following order: > Programming/RF Testing - program the relay and all other devices into the control panel and test RF communication from each intended device location to the control panel. > Mounting - Mount the relay at the tested location. Programming/RF Testing/Mounting The following provides summarized steps for device programming, testing and mounting. For complete details, refer to the control panel installation manual. 1 Loosen the screw, open the box and insert the batteries. Screw 9 Press YES/OK to end the radio range test then press ESC NO. 10 The display shows NAME + LOCATION: Close the box and tighten the screw. Enter appropriate device name/location (up to 16 characters), then press YES/OK. The display shows the device number and name for confirmation. 3 Access to the panel configuration menu. 4 Proceed through menus until the display shows ADD A NEW DEVICE. 11 The display shows ENTERING A NEW DEVICE? Repeat steps 1 - 14 for remaining devices. 5 Press YES/OK. The display shows PRESS PROGRAM BUTTON OF DEVICE. 6 Using a paperclip, press and release the relay INIT button. The contact LED flashes. Wait for the keypad to display TRANSMITTER (1-24) RECORDED. INIT button 7 Press YES/OK. The display shows RADIO RANGE TEST? Press YES/OK again. The IRT LED starts flashing and keypad display shows TEST IN PROGRESS. 8 Take the transmitter to its intended mounting location and make sure that the LED flashes continuously, indicating good communication with the control panel. LED INSTALLATION SHEET INDOOR RELAY TRANSMITTER IRT200 IRT601 IRT702 Remove the base from the contact. 2 Hold the base against the wall and mark the mounting points. Drill. Mount the base on the wall. Mounting brackets 5 Connect 2 AWG22 wires from the devices to trigger (sirens, flashes, cameras, smoke generators, garage doors, etc.) to the input terminals. Connect to the wired devices to trigger Mount the IRT on its base and lock with the screw. INSTALLATION SHEET INDOOR RELAY TRANSMITTER IRT200 IRT601 IRT702 Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit English Français Deutsch • Remove the batteries before any maintenance ! • WARNING, there is a risk of explosion if a battery is replaced by an improper model ! • Observe polarity when setting up the batteries! • Do not litter the batteries when they are used! Dispose of them properly according to Lithium Metal requirements • Retirez les piles avant toute opération de maintenance ! • Attention ! Il y a un risque d'explosion si la batterie utilisée est remplacée par un mauvais modèle ! • Respectez la polarité lors de la mise en place des piles ! • Ne jetez pas les batteries usagées ! Ramenez-les à votre installateur ou à un point de collecte spécialisé. • Batterien vor jeglichen Wartungsarbeiten entfernen! • Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Models ersetzt wird! • Achten Sie beim Einsetzen der Batterien auf die Polung! • Entsorgen Sie Batterien nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien zu den öffentlichen Sammelstellen. FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s) Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : L’appareil ne doit pas produire de brouillage, et 2 L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. INSTALLATION SHEET INDOOR RELAY TRANSMITTER IRT200 IRT601 IRT702 ELECTRICAL PROPERTIES Panel compatibility BOX W panels Type C - CR123A - Lithium battery Battery Nominal voltage 3V Low battery limit 2.8 V Estimated battery life Up to 3 years Current consumption 45 µA Max 35 mA Open-collector 32 g (without battery) Weight Environmental properties Max relative humidity -10°/+55°C 75%, without condensing Installation / Mounting Wall mounting 2 screws 1 screw STANDARDS AND CERTIFICATIONS RF S2View® technology Spread spectrum RF bidirectional 868MHz (IRT 200) Operating frequency • 868MHz - IRT200 (Europe, Africa, Asia) • 915MHz - IRT601 (Americas) • 920MHz - IRT702 (Australia, Chile, Peru, Paraguay) Compliant with the annex IV of the R&TTE Directive 1999/5/EC AES algorithm encryption Transmission security 79.3 mm x 35 mm x 24.6 mm Dimensions Box sealing RADIO PROPERTIES Radio type ABS UL94-V0 Material Operating temperature Standby (1h average) Trigger properties Physical properties 915MHz (IRT 601) Radio, batteries, tamper Supervision Integrated Radio antenna Part 15C USA FCC RSS-247 Issue 1 Canada IC Tamper Tamper detection 920MHz (IRT 702) Cover and wall tamper AS/NZS4268 Australia RCM This symbol on the product or on its packaging indicates that this product should not be treated as household waste. It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health. The recycling of materials will help to conserve natural resources. For more information about recycling of this product, please contact your local municipality, your waste disposal service or the company that installed the product. EMEA SALES 23, avenue du Général Leclerc 92340 BOURG-LA-REINE FRANCE E-Mail : emeasales@rsivideotech.com www.videofied.com North American Headquarters 1375 Willow Lake Blvd, Suite 103 Vadnais Heights, MN 55110 USA E-Mail : usasales@rsivideotech.com The EC declaration of conformity of this product is available by flashing that QR code :
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : fr-FR Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42 Create Date : 2017:01:17 11:46:43+01:00 Metadata Date : 2017:01:17 11:46:45+01:00 Modify Date : 2017:01:17 11:46:45+01:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:1d378ded-b7e5-448a-a5a7-d6a69af86d6e Original Document ID : xmp.did:9FCEE297D587E2118041A147EF51C18F Document ID : xmp.id:9b70ae21-1d8b-dc4c-814b-7ea51305b414 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:f973f9cd-dc3a-3545-a11e-026803725fa5 Derived From Document ID : xmp.did:c61a26ac-efc3-9840-a7a2-385618801356 Derived From Original Document ID: xmp.did:9FCEE297D587E2118041A147EF51C18F Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:01:17 11:46:43+01:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools