RSI VIDEOTECHNOLOGIES SE01 Indoor Siren User Manual
RSI VIDEOTECHNOLOGIES Indoor Siren
User Manual
Indoor Siren SE 200w/601w/702w P R O D U C T I N S T A L L A T I O N S H E E T 2205 - SEIS March 2015 Product Summary Installation Guidelines The Interior Siren SE 200w/601w/702w is a wireless siren designed for use with Videofied security systems. The siren includes the following features: > Totally wireless, battery operated. > Dual tamper function provides detection for both wall and cover tamper. For easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting system devices. Install the siren and other system devices in the order of the following steps: Programming/RF Testing - program siren and all other devices into the control panel and test RF communication from each intended device location to the control panel. Mounting - mount siren at the tested location. > Transmits check-in/status signal every 8 minutes. Programming/RF Testing The following provides summarized steps for device programming and testing. For complete details, refer to the control panel installation manual. Remove bottom screws, separate cover from siren and install batteries. Press Yes. The display shows RADIO RANGE TEST? Press Yes again. The siren LED starts flashing and keypad display shows TEST IN PROGRESS. Put control panel into programming/ configuration mode. Take siren to its intended mounting location and make sure LED flashes continuously, indicating good communication with control panel. Press Yes to end radio range test, then press Esc/No. The display shows RECORDING A NEW DEVICE? Repeat steps 4 - 8 for remaining sirens. Using a programmed alphanumeric keypad, proceed through menus until the display shows ADD A NEW DEVICE. Press Yes. The display shows PRESS PROGRAM BUTTON OF DEVICE. Press and release program button on siren using a paper clip end. The siren LED flashes. Wait for keypad display to show SIREN (1 - 25) RECORDED. Screws 10 When finished, exit from configuration mode. Program Button www.videofied.com I N S T A L L A T I O N S H E E T Indoor Siren SE 200w/601w/702w Mounting Remove batteries. > Use proper tools and hardware. Hold unit up against mounting surface and mark the three mounting holes. Drill pilot holes and install anchors where needed. > Mount where siren can be heard by occupants. > Mount out-of-reach of intruders to help prevent disabling of unit. Electrical Data Mounting Holes Place unit on mounting surface so mounting holes line up with pilot holes/anchors and secure unit with appropriate screws. Install batteries, observing correct polarity. Attach front cover. Physical Data Panel Compatibility XL, XLL, XVIP, Visio, XT, XTIP Material Power requirements Four 1.5 V Alkaline Batteries Dimensions (LxWxD) Nominal Voltage 6V Low Battery Limit 4.2V Battery type D A T A ABS—ULV0 228 mm x 168 mm x 60 mm 9 in. x 6.61 in. x 2.36 in. Weight 740 g/26 oz.(without batteries) Energizer Alkaline LR20, D size Battery life Up to 4 years RF technology S2View® Radio type Installation/Mounting Siren/Base Spread Spectrum Bidirectional Operating frequency 868MHz - SE200w (Europe, South Africa, Asia) 915MHz - FHSS - SE601w (USA, Canada, South America) Two screws secure siren to base; three screws secure siren base to mounting surface. Standards & Certifications 868MHz (SE200w) 920MHz - FHSS - SE702w (Australia, South America) Transmission security Supervision Antenna Tamper detection Speaker impedance Output level AES encryption algorithm Polled signal every 8 minutes Integrated Wall and cover tampered USA FCC (Part 15C) 110 dB @ 1 meter Canada IC (RSS-210 Issue 8) Configured in Control Panel Built-in sounder Emits entry/exit delay beeps, alarms Maximum relative humidity 915MHz (SE601w) 4 ohms Output duration Operating temperature Compliant with the annex IV of the R&TTE Directive 1999/5/EC -10°/+40°C (14°/104°F) 70%, non-condensing 920MHz (SE702w) Australie C-Tick (AS-NZS4268) Ce symbole, apposé sur le produit ou sur son emballage, indique que ce produit ne doit pas être traité avec les déchets ménagers. Il doit être remis à un point de collecte approprié pour le recyclage des équipements électriques et électroniques. En s’assurant que ce produit est bien mis au rebut de manière appropriée, vous aiderez à prévenir les conséquences négatives potentielles pour l’environnement et la santé humaine. Le recyclage des matériaux aidera à préserver les ressources naturelles. Pour toute information supplémentaire au sujet du recyclage de ce produit, vous pouvez contacter votre municipalité, votre déchetterie ou la société qui a installé le produit. P R O D U C T Indoor Siren SE 200/601/702 I N S T A L L S H E E T Notes de sécurité / (EN) Security notes / (DE) Hinweise zur Sicherheit Français • • • • Retirez la pile avant toute opération de maintenance ! Attention ! Il y a un risque d'explosion si la pile utilisée est remplacée par une pile de type incorrect ! Respectez la polarité lors de la mise en place de la pile ! Ne jetez pas la pile usagée ! Ramenez-la à votre installateur ou à un point de collecte spécialisé. English • • • • Remove battery before any maintenance ! WARNING, there is a risk of explosion if a battery is replaced by an incorrect type! Observe polarity when setting up the battery! Do not throw away used battery! Dispose of it properly according to Lithium Metal requirements Deutsch • • • • Batterie vor jeglichen Wartungsarbeiten entfernen! Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Typs ersetzt wird! Achten Sie beim Einsetzen der Batterie auf die Polung! Entsorgen Sie Batterie nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterie zu den öffentlichen Sammelstellen. FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: > Reorient or relocate the receiving antenna. > Increase the separation between the equipment and receiver. > Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. > Consult the dealer or an experienced radio/TV technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1 L’appareil ne doit pas produire de brouillage,et 2 L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. www.videofied.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2014:01:30 18:10:31+01:00 Creator : Adobe InDesign CC (Windows) Modify Date : 2015:03:20 15:55:24+01:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:82d1fa67-5d3b-4523-9c19-5587a35d59c8 Original Document ID : adobe:docid:indd:e28ce908-a672-11dc-a793-af0db84f2b18 Document ID : xmp.id:f469b5aa-a884-b145-873c-63cf6cc027fc Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:78dff404-346e-064c-80f8-8f7f7e5ebb99 Derived From Document ID : adobe:docid:indd:e28ce908-a672-11dc-a793-af0db84f2b18 Derived From Original Document ID: adobe:docid:indd:e28ce908-a672-11dc-a793-af0db84f2b18 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:01:30 18:10:31+01:00 Metadata Date : 2015:03:20 15:55:24+01:00 Creator Tool : Adobe InDesign CC (Windows) Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 3EXIF Metadata provided by EXIF.tools