Radwin RW2025 Outdoor radio unit operating in the 2.5-2.7 GHz (BRS) band User Manual STW

Radwin Ltd. Outdoor radio unit operating in the 2.5-2.7 GHz (BRS) band STW

Contents

User Manual Part 1

Download: Radwin RW2025 Outdoor radio unit operating in the 2.5-2.7 GHz (BRS) band User Manual STW
Mirror Download [FCC.gov]Radwin RW2025 Outdoor radio unit operating in the 2.5-2.7 GHz (BRS) band User Manual STW
Document ID1437358
Application ID1SXWkdjy/tHHOpUJQvY4fQ==
Document DescriptionUser Manual Part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize388.86kB (4860697 bits)
Date Submitted2011-03-24 00:00:00
Date Available2011-03-24 00:00:00
Creation Date2011-03-09 17:34:38
Producing SoftwareAcrobat Distiller 10.0.1 (Windows)
Document Lastmod2011-03-09 17:35:04
Document TitleSTW
Document CreatorFrameMaker 8.0
Document Author: DAF

RADWIN 2000
Broadband Wireless Transmission System
USER MANUAL
RELEASES 2.5.40
UM 2000-2540/02.11
RADWIN 2000
User Manual
Notice
This manual contains information that is proprietary to RADWIN Ltd. (RADWIN hereafter). No
part of this publication may be reproduced in any form whatsoever without prior written
approval by RADWIN.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and
other intellectual property or other proprietary rights relating to this manual and to the
RADWIN products and any software components contained therein are proprietary products
of RADWIN protected under international copyright law and shall be and remain solely with
RADWIN.
The RADWIN name is a registered trademark of RADWIN Ltd. No right, license, or interest to
such trademark is granted hereunder, and you agree that no such right, license, or interest
shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the User Manual
or any other RADWIN documentation or products. You are prohibited from, and shall not,
directly or indirectly, develop, market, distribute, license, or sell any product that supports
substantially similar functionality based or derived in any way from RADWIN products.Your
undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of a RADWIN product package and shall
continue until terminated. RADWIN may terminate this Agreement upon the breach by you of
any term thereof. Upon such termination by RADWIN, you agree to return to RADWIN any
RADWIN products and documentation and all copies and portions thereof.
For further information contact RADWIN at one of the addresses under Worldwide
Contacts below or contact your local distributor.
Disclaimer
The parameters quoted in this document must be specifically confirmed in writing before they
become applicable to any particular order or contract. RADWIN reserves the right to make
alterations or amendments to the detail specification at its discretion. The publication of
information in this document does not imply freedom from patent or other rights of RADWIN,
or others.
Trademarks
WinLink 1000 and RADWIN 2000 are trademarks of RADWIN Ltd.
Windows 2000, XP Pro, Vista, Windows 7 and Internet Explorer are trademarks
of Microsoft Inc.
Mozilla and Firefox are trademarks of the Mozilla Foundation.
Other product names are trademarks of their respective manufacturers.
RADWIN 2000 User Manual
Release 2.5.40
RADWIN Worldwide Offices
Corporate and EMEA Regional Headquarters
Corporate and EMEA Headquarters
27 Habarzel Street
Tel Aviv, 69710
Israel
Tel: +972.3.766.2900
Fax: +972.3.766.2902
Email: sales@radwin.com
North America Regional
Headquarters
900 Corporate Drive
Mahwah, NJ, 07430
USA
Tel: +1-877-RADWIN US
(+1-877 723-9468)
Tel: +1-201-252-4224
Fax: +1-201-621-8911
Email: salesna@radwin.com
Customer Support - North America:
Hours: 9 am - 6 pm EST (Mon - Fri)
Email: supportusa@radwin.com
APAC Regional Headquarters
53A, Grange Road #15-02
Spring Grove ,249566
Singapore
Tel: +65.6638.7864
Email: salessg@radwin.com
RADWIN Regional Offices
RADWIN Brazil
RADWIN Mexico
Av. Chucri Zaidan, 920 – 9º
São Paulo, 04583-904
Brazil
Tel: +55.11.3048-4110
Email: salesbr@radwin.com
Quinto #20 Col El Centinela
Mexico, DF, O4450
Mexico
Tel: +52 (55) 5689 8970
Email: salesmx@radwin.com
RADWIN Peru
RADWIN India
Av. Antares 213
Lima, 33
Peru
Tel: +511.6285105
Fax: +511-990304095
Email: salespe@radwin.com
E-13,B-1 Extn., Mohan Co-operative Industrial Estate
New Delhi, 110 044
India
Tel: +91-11-40539178
Email: salesin@radwin.com
RADWIN Philippines
RADWIN South Africa
5 Bur Bank St.
Laguna, Belair, Santa Rosa
Laguna Philippines
Tel: +63 928 7668230
Email: salesph@radwin.com
P.O. Box 3554, Rivonia
Johannesburg ,2128
South Africa
Tel: +27 (0)82 551 5600
Email: sales@radwin.com
RADWIN Italy and Spain
RADWIN Central America
Piazza Arenella 7/H
Napoli ,80128
Italy
Tel:+390815564116
Fax: +39335433620
Email: salesit@radwin.com
Calle La Cañada # 108-E
Jardines de la Hacienda
Ciudad Merliot El Salvador
Tel: +503 2278-5628
Email: sales@radwin.com
RADWIN South East Asia
All Season Mansion
87/38 Wireless Road Lumpinee
Bangkok ,10330
Thailand
Tel: +66811707503
Email: sales@radwin.com
RADWIN 2000 User Manual
Release 2.5.40
ii
Regulatory Compliance
General Note
This system has achieved Type Approval in various countries around the world. This means
that the system has been tested against various local technical regulations and found to
comply. The frequency bands in which the system operates may be “unlicensed” and in these
bands, the system can be used provided it does not cause interference.
FCC - Compliance
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Warning
Warning
Caution
It is the responsibility of the installer to ensure that when using the outdoor
antenna kits in the United States (or where FCC rules apply), only those
antennas certified with the product are used. The use of any antenna other
than those certified with the product is expressly forbidden by FCC rules 47
CFR part 15.204.
It is the responsibility of the installer to ensure that when configuring the
radio in the United States (or where FCC rules apply), the Tx power is set
according to the values for which the product is certified. The use of Tx
power values other than those, for which the product is certified, is
expressly forbidden by FCC rules 47 CFR part 15.204.
Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may void the product
warranty and may expose the end user or the service provider to legal and
financial liabilities. Resellers or distributors of this equipment are not liable
for injury, damage or violation of regulations associated with the installation
of outdoor units or antennas. The installer should configure the output
power level of antennas according to country regulations and antenna type.
RADWIN 2000 User Manual
Release 2.5.40
iii
•
•
Warning
•
Where Outdoor units are configurable by software to Tx power values
other than those for which the product is certified, it is the responsibility of the Professional Installer to restrict the Tx power to the certified limits.
The RADWIN 2000 2.5GHz BAND device (FCC ID: Q3KRW2025) complies with FCC RF radiation exposure limits. This equipment should be
installed and operated with a minimum distance of 104.6cm between
the radiator and your body for 2.5 GHz operations
This product was tested with special accessories - indoor unit (IDU or
PoE), FTP CAT-5e shielded cable with sealing gasket, 12 AWG
grounding cable - which must be used with the unit to insure compliance.
Indoor Units comply with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) These devices may not cause harmful interference.
(2) These devices must accept any interference received, including interference that may
cause undesired operation.
Canadian Emission Requirements for Indoor Units
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numẻrique de la classe B est conforme ả la norme NMB-003 du Canada.
China MII
Operation of the equipment is only allowed under China MII 5.8GHz band regulation
configuration with EIRP limited to 33 dBm (2 Watt).
India WPC
Operation of the equipment is only allowed under India WPC GSR-38 for 5.8GHz band
regulation configuration.
Unregulated
In countries where the radio is not regulated the equipment can be operated in any regulation
configuration, best results will be obtained using Universal regulation configuration.
Safety Practices
Applicable requirements of National Electrical Code (NEC), NFPA 70; and the National
Electrical Safety Code, ANSI/IEEE C2, must be considered during installation.
NOTES:
1. A Primary Protector is not required to protect the exposed wiring as long as the exposed
wiring length is limited to less than or equal to 140 feet, and instructions are provided to
avoid exposure of wiring to accidental contact with lightning and power conductors in
accordance with NEC Sections 725-54 (c) and 800-30.
In all other cases, an appropriate Listed Primary Protector must be provided. Refer to Articles
800 and 810 of the NEC for details.
2. For protection of ODU against direct lightning strikes, appropriate requirements of NFPA
780 should be considered in addition to NEC.
RADWIN 2000 User Manual
Release 2.5.40
iv
3. For Canada, appropriate requirements of the CEC 22.1 including Section 60 and additional
requirements of CAN/CSA-B72 must be considered as applicable.
RADWIN 2000 User Manual
Release 2.5.40
Brief
Table of Contents
Part 1: Basic Installation
Chapter 1 Introduction
Chapter 2 Site Preparation
Chapter 3 Hardware Installation
Chapter 4 Getting Started with the RADWIN Manager
Chapter 5 Installing the Link
Chapter 6 The RADWIN Manager: Main Window
Chapter 7 Configuring the Link
Chapter 8 Site Configuration
Chapter 9 Monitoring and Diagnostics
Part 2: Site Synchronization
Chapter 10 Hub Site Synchronization
Chapter 11 Using the RADWIN GSU
Part 3: Advanced Installation
Chapter 12 Monitored Hot Standby Installation Procedure
Chapter 13 The RADWIN Ethernet Ring
Chapter 14 VLAN Functionality with RADWIN 2000
Chapter 15 Software Upgrade
Chapter 16 FCC/IC DFS Installation Procedure
Part 4: Field Installation Topics
Chapter 17 Pole and Wall Installation
Chapter 18 Lightning Protection and Grounding Guidelines
Chapter 19 Preloading an ODU with an IP Address
Chapter 20 Changing the Factory Default Band
Chapter 21 Link Budget Calculator
Chapter 22 Quick Install Mode
Part 5: Product Dependent Features
Chapter 23 Spectrum View
Chapter 24 BRS/EBS Considerations
Chapter 25 Quality of Service
Part 6: Product Reference
Appendix A Technical Specifications
Appendix B Wiring Specifications
Appendix C Small Form-factor Pluggable Transceiver
Appendix D MIB Reference
Appendix E External Alarms Specification
Appendix F RF Exposure
Appendix G Regional Notice: French Canadian
Index
RADWIN 2000 User Manual
Release 2.5.40
vi
Full
Table of Contents
Notice............................................................................................................................. i
RADWIN Worldwide Offices ............................................................................................. ii
Regulatory Compliance....................................................................................................iii
Part 1: Basic Installation
Chapter 1 Introduction
Welcome to RADWIN 2000! ......................................................................... 1-1
RADWIN 2000 highlights: ............................................................................ 1-1
What’s new in Release 2.5.40 ...................................................................... 1-2
Terminology ............................................................................................ 1-2
More About New and Extended RADWIN 2000 Products ................................... 1-2
RADWIN 2000 C-series 3.X Products ............................................................... 1-2
RADWIN 2000 C-series BRS Products .............................................................. 1-3
RADWIN 2000 X-series for 3.X Products ......................................................... 1-3
Summary. ..................................................................................................... 1-3
Key Applications.......................................................................................... 1-4
Cellular Backhaul ..................................................................................... 1-4
Broadband Access ................................................................................... 1-4
Mobility Applications ................................................................................. 1-5
Border Control............................................................................................... 1-5
Installation Security ....................................................................................... 1-5
Railway solutions ........................................................................................... 1-5
Key Features of RADWIN 2000 .................................................................. 1-5
Components of a RADWIN 2000 Link............................................................ 1-8
The Outdoor Unit (ODU) ............................................................................ 1-8
The Indoor Unit (IDU) ............................................................................... 1-9
New style IDU-E for both WinLink 1000 and RADWIN 2000 ............................ 1-10
IDU-C ......................................................................................................... 1-10
Power Over Ethernet (PoE) Devices ........................................................... 1-11
Basic PoE Device ......................................................................................... 1-11
GSU .................................................................................................... 1-11
Antennas .............................................................................................. 1-12
RADWIN Manager .................................................................................. 1-13
RADWIN Network Management System (RNMS) .......................................... 1-14
Accessories ........................................................................................... 1-14
.......................................................................................................... 1-15
Documentation supplied with RADWIN 2000 ................................................ 1-15
How to Use this Manual............................................................................. 1-15
A Little Terminology ................................................................................. 1-16
Conventions Used in this Manual ................................................................ 1-17
Notifications .......................................................................................... 1-17
Typographical conventions ....................................................................... 1-17
General....................................................................................................... 1-17
Software ..................................................................................................... 1-17
Windows Terminology ............................................................................. 1-18
Viewing and Printing ............................................................................... 1-19
Chapter 2 Site Preparation
Planning the Link Site.................................................................................. 2-1
Overview ................................................................................................ 2-1
The Site Survey .......................................................................................... 2-1
Introduction ............................................................................................ 2-1
Recommended Equipment ......................................................................... 2-1
Stage 1: Preliminary Survey ......................................................................... 2-2
RADWIN 2000 User Manual
Release 2.5.40
vii
Stage 2: Physical Survey .............................................................................. 2-3
Additional Outdoor Site Requirements ........................................................... 2-3
Additional Indoor Site Requirements ............................................................. 2-3
Stage 3: RF Survey...................................................................................... 2-4
RF Planning for Dense Installations and Collocated Sites ................................ 2-4
Chapter 3 Hardware Installation
Safety Practices...........................................................................................3-1
Preventing overexposure to RF energy ..........................................................3-1
Grounding ...............................................................................................3-1
Protection against Lightning ....................................................................... 3-2
General .................................................................................................. 3-2
Package Contents........................................................................................ 3-2
ODU Package Contents .............................................................................. 3-2
IDU-E package containing: ......................................................................... 3-4
IDU-C Package Contents ............................................................................ 3-4
External Antenna Package Contents ............................................................. 3-5
Additional Tools and Materials Required ........................................................3-5
Tools and Materials ...................................................................................3-5
Cables and connectors ...............................................................................3-5
Hardware Installation Sequence ................................................................... 3-6
Outdoor installation .....................................................................................3-7
Preparing the ODU before Deployment ......................................................... 3-7
Mounting the ODU .................................................................................... 3-7
Mounting external antennas ....................................................................... 3-7
Mounting the Lightning Protection Devices ....................................................3-8
Outdoor Connections .................................................................................3-8
Indoor Installation.......................................................................................3-8
Installing IDU-E ...................................................................................... 3-8
IDU-E Installation ..........................................................................................3-8
Mounting the IDU-C .................................................................................. 3-9
Connecting power to the IDU .................................................................... 3-11
Connecting the ODU to the IDU ................................................................. 3-12
Installing a Link using PoE Devices ............................................................. 3-12
Connecting User Equipment ...................................................................... 3-12
Connecting and Aligning ODUs / Antennas .................................................. 3-13
Chapter 4 Getting Started with the RADWIN Manager
Installing the RADWIN Manager Application ..................................................4-1
Minimum System Requirements ................................................................... 4-1
Installing the Software .............................................................................. 4-1
Getting Started with the RADWIN Manager ................................................... 4-2
The RADWIN Manager log-on Concept..........................................................4-4
Log-on Errors and Cautions.......................................................................... 4-6
Unsupported Device .................................................................................. 4-6
Incorrect IP Address .................................................................................4-7
Incorrect Password ...................................................................................4-7
Invalid Read/Write Community String ........................................................... 4-7
Logging in to the Over-the-Air Site ............................................................... 4-7
Continuing without an IP Address ................................................................. 4-8
Changing the Log-On Password ................................................................... 4-8
First steps...................................................................................................4-9
Default RADWIN 2000 Settings ................................................................. 4-11
Using RADWIN Manager Spectrum View ..................................................... 4-11
Chapter 5 Installing the Link
Overview .................................................................................................... 5-1
Installation .................................................................................................5-3
Step 1, Start the Wizard .............................................................................. 5-3
RADWIN 2000 User Manual
Release 2.5.40
viii
Step 2, System Parameters ......................................................................... 5-3
Changing the Link Password ....................................................................... 5-5
Step 3, Channel Settings .............................................................................5-7
Step 4, Tx Power and Antenna Settings ....................................................... 5-9
About Single and Dual Antennas ..................................................................5-9
Dual Antennas at Both Sites ...........................................................................5-9
Single Antennas at Both Sites ...................................................................... 5-10
Single at One Site, Dual Antennas at the Other ............................................. 5-10
Considerations for Changing Antenna Parameters ......................................... 5-12
Step 5, Hub Site Synchronization Settings .................................................. 5-16
Step 6, Services ....................................................................................... 5-16
Limitations on the use of Asymmetric Allocation ............................................ 5-19
Asymmetric Allocation and Collocation ........................................................ 5-19
Asymmetric Allocation and TDM ................................................................ 5-20
TDM Services selection ............................................................................ 5-20
Modulation Rate Selection ........................................................................ 5-23
Setting Monitored Hot Standby Mode ......................................................... 5-23
Ethernet Ring ........................................................................................ 5-24
Ethernet QoS ......................................................................................... 5-24
Setting the TDM Jitter Buffer .................................................................... 5-24
Step 7, TDM Clock Configuration ............................................................... 5-27
Step 8, Installation Summary and Exit ....................................................... 5-29
Chapter 6 The RADWIN Manager: Main Window
One Manager for all RADWIN Radio Products ................................................6-1
The Main Window of the RADWIN Manager................................................... 6-1
The RADWIN Manager Toolbar..................................................................... 6-2
Main Menu Functionality .............................................................................. 6-3
Elements of the RADWIN Manager Main Window........................................... 6-4
Chapter 7 Configuring the Link
Overview .................................................................................................... 7-1
Configuration .............................................................................................. 7-3
Step 1, Start the Wizard .............................................................................. 7-3
Step 2, System Parameters ......................................................................... 7-3
Step 3, Channel Settings .............................................................................7-4
Step 4, Tx Power and Antenna Settings ....................................................... 7-8
Changing Number of Antennas and Tx Power ................................................. 7-8
TX Power, Antenna Gain and Cable Loss .........................................................7-8
Switching Between Single and Dual Antennas .................................................7-9
Switching Between MIMO and Diversity Modes ............................................. 7-10
Step 5, Hub Site Synchronization Settings .................................................. 7-10
Step 6, Services ....................................................................................... 7-10
Step 7, TDM Clock Configuration ............................................................... 7-11
Step 8, Configuration Summary and Exit .................................................... 7-12
Chapter 8 Site Configuration
Configuring the Site.....................................................................................8-1
Editing the Configuration Parameters by Site ..................................................8-1
Functions on the left of the dialog box:............................................................8-2
Functions at the top of the dialog box: ............................................................8-2
Viewing System Details ................................................................................ 8-3
Viewing Air Interface Details ........................................................................ 8-3
Changing the Transmit Power ...................................................................... 8-3
Hub Site Sync .............................................................................................8-4
Site Management: IP Address, VLAN and Protocol ......................................... 8-5
Configuring the ODU Address ...................................................................... 8-5
Configuring VLAN Settings .......................................................................... 8-6
Lost or forgotten VLAN ID .......................................................................... 8-7
RADWIN 2000 User Manual
Release 2.5.40
ix
Enable / Disable Telnet Access ....................................................................8-8
Displaying the Inventory .............................................................................. 8-8
Security Features ........................................................................................ 8-9
Changing the Link Password ....................................................................... 8-9
RADWIN Manager Community Strings ..........................................................8-9
Editing Community Strings............................................................................8-10
Forgotten Community string ......................................................................... 8-10
Link Lock Security Feature ........................................................................ 8-11
Setting the Date and Time ......................................................................... 8-13
Ethernet Properties.................................................................................... 8-15
Configuring the Bridge ............................................................................. 8-15
ODU Mode...................................................................................................8-16
IDU Aging time ............................................................................................ 8-16
Configuring Ethernet Ports Mode ............................................................... 8-17
VLAN Tagging for Ethernet Service: Configuration ......................................... 8-17
Setting the Maximum Information Rate (MIR) .............................................. 8-19
What is the MIR........................................................................................... 8-19
What is it for ...............................................................................................8-19
TDM MHS Status ....................................................................................... 8-21
Setting External Alarm Inputs..................................................................... 8-21
Resetting .................................................................................................. 8-22
IDU Detection ........................................................................................... 8-23
Backup/Restore of ODU Software Files........................................................ 8-24
Backup ODU Software to a File .................................................................. 8-24
Restoring ODU Software or Configuration .................................................... 8-24
Muting the alignment tone buzzer............................................................... 8-25
Configuration with Telnet........................................................................... 8-25
Chapter 9 Monitoring and Diagnostics
Retrieving Link Information (Get Diagnostics)................................................9-1
Link Compatibility ........................................................................................ 9-3
TDM Loopbacks...........................................................................................9-3
Local Line Loopback .................................................................................. 9-6
Remote Reverse Loopback ......................................................................... 9-6
Remote Line Loopback .............................................................................. 9-6
Local Internal Loopback .............................................................................9-7
Reinstalling and Realigning a Link................................................................. 9-7
The Link Budget Calculator .......................................................................... 9-8
Throughput Checking .................................................................................. 9-8
Performance Monitoring...............................................................................9-8
The Monitor Log .......................................................................................9-9
Saving the Monitor Log...................................................................................9-9
Viewing Performance Reports .........................................................................9-9
Performance Monitoring Report Toolbar.........................................................9-12
Setting Air Interface Thresholds .................................................................... 9-12
Events, Alarms and Traps .......................................................................... 9-13
The Events Log ...................................................................................... 9-13
RADWIN Manager Traps .......................................................................... 9-15
Setting the Events Preferences .................................................................. 9-16
Saving the Events Log ............................................................................. 9-17
Active Alarms ........................................................................................ 9-17
Viewing Recent Events ............................................................................ 9-18
Reverting Alert Messages ........................................................................... 9-18
Other Advanced Preferences ...................................................................... 9-19
Enable and Disable Checking for Software Updates ....................................... 9-19
Setting the RADWIN Manager Language ..................................................... 9-19
Setting SNMP Parameters ......................................................................... 9-19
RADWIN 2000 User Manual
Release 2.5.40
Remote Power Fail Indication ..................................................................... 9-19
Troubleshooting ........................................................................................ 9-19
Replacing an ODU ..................................................................................... 9-20
Restoring Factory Setup............................................................................. 9-21
Online Help............................................................................................... 9-21
Customer Support ..................................................................................... 9-21
Part 2: Site Synchronization
Chapter 10 Hub Site Synchronization
What is Hub Site Synchronization?.............................................................. 10-1
Hardware Installation ................................................................................ 10-3
Connecting an HSS Unit ........................................................................... 10-3
Using a Single HSS Unit ........................................................................... 10-4
Using More than One HSS Unit .................................................................. 10-5
Condition 1: Cabling Sequence...................................................................... 10-5
Condition 2: Total HSS Cable Length .............................................................10-6
HSS Error Notification ................................................................................ 10-6
ODU/HSS Unit Connection Pinout ............................................................... 10-7
Radio Frame Pattern (RFP)......................................................................... 10-7
Without HSS .......................................................................................... 10-7
RFP and HSS ......................................................................................... 10-7
RFP: General Radio Frame Pattern ............................................................. 10-8
RFP: RADWIN 2000 Considerations ............................................................ 10-9
RFP: WinLink 1000 Considerations ........................................................... 10-11
HSS Status LED on the IDU-C and New Style IDU-E ................................... 10-12
Link Configuration and HSS...................................................................... 10-12
Site Configuration and HSS ...................................................................... 10-14
Chapter 11 Using the RADWIN GSU
What is it for............................................................................................. 11-1
GSU Functionality ...................................................................................... 11-1
Typical GSU Scenarios ............................................................................... 11-1
Independent Distributed Sites ................................................................... 11-1
Multiple Distributed Sites with Communication .............................................. 11-2
Cascaded Sites using Shifted Phase Transmission ......................................... 11-3
GSU Redundancy ...................................................................................... 11-3
GSU Kit Contents....................................................................................... 11-4
GSU Installation ........................................................................................ 11-4
Overview .............................................................................................. 11-4
Preparing the GSU for Use ........................................................................ 11-5
Mounting the GSU .................................................................................. 11-5
Configuring the GSU ............................................................................... 11-5
Getting Started ............................................................................................ 11-5
Using Site Configuration for the GSU .............................................................11-7
GSU Preferences .................................................................................. 11-12
GSU Monitoring and Diagnostics ............................................................... 11-12
GSU Telnet Support................................................................................. 11-12
Software Update for GSUs........................................................................ 11-13
Part 3: Advanced Installation
Chapter 12 Monitored Hot Standby Installation Procedure
What is a RADWIN Monitored Hot Standby.................................................. 12-1
What RADWIN MHS provides ..................................................................... 12-2
Equipment Protection .............................................................................. 12-2
Air-Interface Protection ............................................................................ 12-2
Purpose of this Chapter ............................................................................. 12-3
Who Should Read this ............................................................................... 12-3
RADWIN MHS Kit Contents......................................................................... 12-3
RADWIN 2000 User Manual
Release 2.5.40
xi
Installing a RADWIN MHS .......................................................................... 12-3
Maintaining a RADWIN MHS Link................................................................ 12-9
IDU Replacement ................................................................................... 12-9
ODU Replacement ................................................................................ 12-10
Switching Logic ....................................................................................... 12-10
Switching from Primary Link to Secondary Link ........................................... 12-10
Switching back from the Secondary to the Primary Link ................................ 12-12
System Operation description ................................................................. 12-14
Chapter 13 The RADWIN Ethernet Ring
Scope ....................................................................................................... 13-1
What is an Ethernet Ring ........................................................................... 13-1
Some terminology: ................................................................................. 13-1
RADWIN Ethernet Ring .............................................................................. 13-2
Ethernet Ring Topologies Supported by RADWIN......................................... 13-4
Protection Switching .................................................................................. 13-6
Hardware Considerations ........................................................................... 13-6
Special Case: 1 + 1 Ethernet Redundancy ................................................... 13-6
Using RADWIN Manager to Set up a Ring.................................................... 13-7
Chapter 14 VLAN Functionality with RADWIN 2000
VLAN Tagging - Overview .......................................................................... 14-1
VLAN Terminology .................................................................................. 14-1
VLAN Background Information on the WEB .................................................. 14-1
VLAN Tagging ........................................................................................ 14-1
QinQ (Double Tagging) for Service Providers ............................................... 14-2
VLAN Untagging ..................................................................................... 14-2
Port Functionality ................................................................................... 14-2
Ingress Direction.......................................................................................... 14-3
Egress Direction........................................................................................... 14-3
VLAN Availability ....................................................................................... 14-5
VLAN Configuration Using the RADWIN Manager ......................................... 14-5
Management Traffic and Ethernet Service Separation .................................... 14-6
VLAN Tagging for Ethernet Service: Configuration ......................................... 14-6
Chapter 15 Software Upgrade
What is the Software Upgrade Utility? ......................................................... 15-1
Upgrading an Installed Link........................................................................ 15-1
Software Update for GSUs.......................................................................... 15-5
Chapter 16 FCC/IC DFS Installation Procedure
FCC/IC 5.4/5.3 GHz Links: Background ....................................................... 16-1
FCC/IC 5.4/5.3 GHz Link Activation............................................................. 16-1
FCC/IC 5.4/5.3 GHz Link Configuration........................................................ 16-4
Part 4: Field Installation Topics
Chapter 17 Pole and Wall Installation
ODU Mounting Kit Contents........................................................................ 17-1
Mounting an ODU on a Pole ....................................................................... 17-2
Mounting an ODU on a Wall ....................................................................... 17-3
Mounting an External Antenna ................................................................... 17-4
Mounting a Connectorized ODU Horizontally................................................ 17-4
Chapter 18 Lightning Protection and Grounding Guidelines
Grounding for Antenna Cable ..................................................................... 18-1
Grounding for Indoor/Outdoor Units ........................................................... 18-2
ODU Grounding ...................................................................................... 18-2
IDU Grounding ....................................................................................... 18-3
External Lightning Surge Suppressors and Grounding................................... 18-3
Internal ESD Protection circuits .................................................................. 18-8
RADWIN 2000 User Manual
Release 2.5.40
xii
Chapter 19 Preloading an ODU with an IP Address
Why this is Needed? .................................................................................. 19-1
Required Equipment .................................................................................. 19-1
The procedure .......................................................................................... 19-2
Tip: How to Recover a Forgotten ODU IP Address ....................................... 19-6
Chapter 20 Changing the Factory Default Band
Why this is Needed.................................................................................... 20-1
Required Equipment .................................................................................. 20-1
The procedure .......................................................................................... 20-1
Changing Band for DFS.............................................................................. 20-5
Special Products or Features: Entering a License Key ................................... 20-5
Provisions for Licensed 3.X and 2.5 GHz Bands........................................... 20-6
Overview .............................................................................................. 20-6
3.X Bands.................................................................................................... 20-6
2.5GHz Bands for BRS/EBS ........................................................................... 20-7
Terminology Recap ................................................................................. 20-7
Regulatory Considerations for 3.650-3.675 GHz FCC/IC part 90 sub part Z ......... 20-7
Restricted Mode........................................................................................... 20-7
Transmission power options..........................................................................20-8
Higher Transmission Power Options and Restrictions: ..................................... 20-8
Availability Summary for FCC/IC and Universal 3.X GHz ..................................20-9
Band Splitting for ETSI 3.4 - 3.7GHz .......................................................... 20-9
Using he RADWIN Manager to set up a 3.X or BRS Link ................................ 20-9
Inactive and Active Mode..............................................................................20-9
Chapter 21 Link Budget Calculator
Overview .................................................................................................. 21-1
User Input ............................................................................................ 21-1
Link Budget Calculator Internal Data .......................................................... 21-1
Calculations .............................................................................................. 21-2
EIRP .................................................................................................... 21-2
Expected RSS and Fade Margin ................................................................. 21-2
Min and Max Range ................................................................................ 21-2
Service ................................................................................................. 21-2
Availability ............................................................................................ 21-2
Antenna Height ...................................................................................... 21-3
About the Fresnel Zone.............................................................................. 21-3
Running the Link Budget Calculator ........................................................... 21-5
Chapter 22 Quick Install Mode
Why this is Needed.................................................................................... 22-1
Enabling Quick Install ................................................................................ 22-1
Using Quick Install .................................................................................... 22-2
Part 5: Product Dependent Features
Chapter 23 Spectrum View
What is Spectrum View? ............................................................................ 23-1
Running Spectrum View in Installation Mode ............................................... 23-1
Understanding the Spectrum View Display .................................................. 23-4
Information Displayed ............................................................................. 23-4
Changing the Display .............................................................................. 23-5
Restricting the Panels to be Displayed ........................................................ 23-8
Saving a Spectrum Analysis ...................................................................... 23-8
Management Integration ........................................................................ 23-10
Chapter 24 BRS/EBS Considerations
What is BRS/EBS ....................................................................................... 24-1
BRS/EBS Bands ......................................................................................... 24-1
Post transition frequency assignments according to FCC CFR47 PART 27 section 27.5:2009
RADWIN 2000 User Manual
Release 2.5.40
xiii
24-2
Setting up a BRS/EBS link using RADWIN 2000 2.5GHz Band ....................... 24-4
Chapter 25 Quality of Service
Availability ................................................................................................ 25-1
QoS - Overview ......................................................................................... 25-1
Setting up QoS.......................................................................................... 25-2
Disabling QoS ........................................................................................... 25-4
Part 6: Product Reference
Appendix A Technical Specifications
Scope of these Specifications .......................................................................A-1
ODU ...........................................................................................................A-1
IDU ............................................................................................................A-3
PoE Device - Indoor, AC...............................................................................A-5
PoE Device - Outdoor, DC ............................................................................A-6
GSU ...........................................................................................................A-6
Antenna Characteristics ...............................................................................A-7
Appendix B Wiring Specifications
ODU-IDU Cable ...........................................................................................B-1
ODU/HSS Unit Connection Pinout .................................................................B-1
User Port Connectors..................................................................................B-2
LAN Port .................................................................................................B-2
Trunk Ports - E1/T1 RJ45 Connector ............................................................B-2
Hot Standby Port RJ-11 .............................................................................B-2
IDU (all models) Alarm Connector ................................................................B-3
DC Power Terminals ....................................................................................B-4
IDU-C & E ...............................................................................................B-4
DC PoE ...................................................................................................B-4
Appendix C Small Form-factor Pluggable Transceiver
IDU-C SFP Support ......................................................................................C-1
Appendix D MIB Reference
Introduction............................................................................................... D-1
About the MIB ........................................................................................ D-1
Terminology ........................................................................................... D-1
Interface API ............................................................................................. D-1
Control Method ....................................................................................... D-1
Community String .................................................................................... D-2
Private MIB Structure ................................................................................. D-2
MIB Parameters ......................................................................................... D-3
Supported Variables from the RFC 1213 MIB ................................................. D-4
MIB Parameters ...................................................................................... D-6
MIB Traps.................................................................................................D-23
General ................................................................................................D-23
Trap Parameters ....................................................................................D-24
RADWIN Manager Traps ............................................................................D-28
Appendix E External Alarms Specification
External Alarms Specification........................................................................E-1
IDU-C and new style IDU-E Alarms ..............................................................E-1
Appendix F RF Exposure
Appendix G Regional Notice: French Canadian
Procédures de sécurité ............................................................................... G-1
Généralités ............................................................................................. G-1
Mise à la terre ........................................................................................ G-1
Protection contre la foudre ........................................................................ G-1
Précautions de sécurité pendant le montage de ODU ...................................... G-2
Connecter la terre à IDU-C ........................................................................ G-2
RADWIN 2000 User Manual
Release 2.5.40
xiv
Installation sur pylône et mur...................................................................... G-2
Contenu du kit de montage ODU ................................................................ G-3
Montage sur un pylône ............................................................................. G-3
Montage sur un mur ................................................................................ G-5
Montage d'une antenne externe ................................................................. G-6
Contenu du kit de montage d'une antenne externe ........................................ G-6
Index
RADWIN 2000 User Manual
Release 2.5.40
xv
List of Tables
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
1-1 SUMMARY: FREQUENCIES FOR RADWIN 2000 C and RADWIN 2000 X SERIES1-3
1-2 USER MANUAL - GENERAL LAYOUT ......................................................... 1-15
1-3 USER MANUAL LAYOUT ........................................................................ 1-15
3-1 COMPONENTS OF AN IDU-C FRONT PANEL..................................................3-9
3-2 IDU-C FRONT PANEL LEDS ................................................................. 3-10
3-3 IDU-C AND NEW STYLE IDU-E FRONT PANEL LEDS FOR HSS ..................... 3-11
4-1 PC REQUIREMENTS FOR THE RADWIN MANAGER APPLICATION ...................... 4-1
4-2 USER TYPES, DEFAULT PASSWORDS AND FUNCTION .......................................4-5
4-3 RADWIN MANAGER: OFFLINE FUNCTIONALITY ........................................... 4-8
4-4 DEFAULT SETTINGS ............................................................................ 4-11
5-1 LINK INSTALLATION WIZARD ................................................................... 5-2
5-2 MIMO - DIVERSITY SETTINGS ............................................................... 5-11
5-3 RADWIN 2000 AIR RATES .................................................................. 5-11
5-4 ASYMMETRIC ALLOCATION WITH COLLOCATED LINKS - SCENARIOS ................. 5-19
6-1 RADWIN MANAGER TOOLBAR ............................................................... 6-2
6-2 RADWIN MANAGER MAIN MENU FUNCTIONALITY ......................................... 6-3
6-3 STATUS BAR INDICATORS ....................................................................... 6-7
7-1 LINK CONFIGURATION WIZARD ................................................................7-2
8-1 ODU MODE CONFIGURATION FOR COMMON SCENARIOS ................................ 8-17
8-2 TELNET COMMANDS SUMMARY ............................................................... 8-26
9-1 GET DIAGNOSTICS DATA AND DESCRIPTION ............................................... 9-2
9-2 LINK COMPATIBILITY TRAP MESSAGES ....................................................... 9-3
9-3 EXPLANATION OF PERFORMANCE DATA ..................................................... 9-11
9-4 ACTION OF THE TOOLBAR BUTTONS ........................................................ 9-12
9-5 RADWIN MANAGER TRAP MESSAGES ..................................................... 9-15
9-6 ACTIVE ALARMS COMMAND BUTTONS ....................................................... 9-17
9-7 LED FAULT INDICATORS....................................................................... 9-19
9-8 SYSTEM TROUBLESHOOTING .................................................................. 9-20
10-1 ODU/HSS UNIT CONNECTION PINOUT.................................................. 10-7
10-2 RADIO FRAME PATTERN TABLE - RADWIN 2000 .................................... 10-8
10-3 RADIO FRAME PATTERN TABLE - WINLINK 1000 ..................................... 10-8
10-4 ASYMMETRIC ALLOCATION WITH COLLOCATED LINKS - SCENARIOS ............. 10-11
10-5 IDU-C AND NEW STYLE IDU-E FRONT PANEL LEDS FOR HSS ................. 10-12
10-6 EXTERNAL PULSE STATUS ................................................................. 10-13
13-1 TOPOLOGIES SUPPORTED BY RADWIN ETHERNET RING ............................ 13-4
14-1 PORT SETTINGS - INGRESS DIRECTION ................................................... 14-3
14-2 PORT SETTINGS - EGRESS DIRECTION .................................................... 14-3
17-1 BILL OF MATERIALS: ODU MOUNTING KIT .............................................. 17-1
20-1 FCC/IC COMPLIANCE BY ANTENNA AND TRANSMISSION POWER .................... 20-8
20-2 HIGHER TRANSMISSION POWER LIMITS.................................................. 20-8
20-3 AVAILABILITY FOR FCC/IC AND UNIVERSAL 3.X GHZ ............................... 20-9
20-4 BAND SPLIT FOR ETSI 3.4-3.7GHZ ..................................................... 20-9
24-1 BRS/EBS LOWER BAND SEGMENT (LBS) .............................................. 24-3
24-2 BRS/EBS MIDDLE BAND SEGMENT (MBS)............................................. 24-3
24-3 BRS/EBS TO RADWIN 2000 CBW MAPPING AND MAX TX POWER ............. 24-3
24-4 BRS/EBS UPPER BAND SEGMENT (UBS)............................................... 24-3
25-1 DEFAULT PRIORITIES AN D ALLOCATION BY VLAN ID AND DIFFSERV............. 25-1
B-1 ODU-IDU RJ-45 CONNECTOR PINOUT .....................................................B-1
B-2 ODU/HSS UNIT CONNECTION PINOUT .....................................................B-1
B-3 FAST ETHERNET CONNECTOR PINOUT .......................................................B-2
B-4 TRUNK PORTS - E1/T1 RJ45PINOUT .......................................................B-2
B-5 HOT STANDBY RJ-11 PORT PINOUT .........................................................B-2
RADWIN 2000 User Manual
Release 2.5.40
xvi
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
B-6 IDU ALARM CONNECTOR (DRY-CONTACT) .................................................B-3
B-7 TERMINAL BLOCK 3-PIN -48VDC.............................................................B-4
B-8 TERMINAL BLOCK 2-PIN -48VDC.............................................................B-4
C-1 SFP TYPE AND INTERFACE DESCRIPTION ....................................................C-1
D-1 SUPPORTED RFC 1213 VARIABLES ......................................................... D-4
D-2 PRIVATE MIB PARAMETERS ................................................................... D-6
D-3 MIB TRAPS ......................................................................................D-24
E-1 IDU-C/E - OUTPUT ALARMS DESCRIPTION ................................................E-1
E-2 IDU-C - INPUT ALARMS DESCRIPTION ......................................................E-2
F-1 SAFETY DISTANCES FOR RADWIN 2000 FCC AND IC PRODUCTS ................... F-1
F-2 SAFETY DISTANCES FOR RADWIN 2000 ETSI PRODUCTS ............................ F-1
RADWIN 2000 User Manual
Release 2.5.40
xvii
List of Figures
FIGURE 1-1 TYPICAL CELLULAR BACKHAUL APPLICATION ............................................... 1-4
FIGURE 1-2 TYPICAL BROADBAND ACCESS APPLICATION ............................................... 1-4
FIGURE 1-3 TYPICAL WIFI BACKHAUL APPLICATION ....................................................1-5
FIGURE 1-4 ODU FORM FACTORS .......................................................................... 1-9
FIGURE 1-5 NEW STYLE IDU-E - FRONT VIEW (NOTE NEW HSS LED ON THE LEFT) ........ 1-10
FIGURE 1-6 NEW STYLE IDU-E: REAR PANEL .......................................................... 1-10
FIGURE 1-7 IDU-C, ETHERNET ONLY, FRONT PANEL ................................................. 1-10
FIGURE 1-8 IDU-C, 16 E1/T1 PORTS, FRONT PANEL ................................................ 1-11
FIGURE 1-9 BASIC POE DEVICE - SHOWING THE RADIO ETHERNET PORT ........................ 1-11
FIGURE 1-10 RUGGEDIZED DC-POE DEVICE: INPUT IS -20 TO -60 VDC (SINGLE INPUT).. 1-11
FIGURE 1-11 GENERAL GSU CONFIGURATION .......................................................... 1-12
FIGURE 1-12 ODU WITH INTEGRATED FLAT PANEL ANTENNA ...................................... 1-13
FIGURE 1-13 EXTERNAL ANTENNAS FOR USE WITH RADWIN 2000 ............................. 1-13
FIGURE 1-14 RADWIN MANAGER WINDOW............................................................ 1-14
FIGURE 1-15 MENU NAVIGATION IN THE RADWIN MANAGER ..................................... 1-18
FIGURE 1-16 SITE CONFIGURATION WINDOW WITH OPEN MANAGEMENT PANEL ............... 1-19
FIGURE 3-1 ODU MOUNTING KIT ...........................................................................3-3
FIGURE 3-2 CONNECTORIZED ODU - FRONT AND REAR VIEWS ...................................... 3-3
FIGURE 3-3 INTEGRATED ODU - FRONT AND REAR VIEWS ............................................ 3-4
FIGURE 3-4 IDU-E- FRONT VIEW ...........................................................................3-4
FIGURE 3-5 IDU-C PACKAGE CONTENTS - THE IDU-C, ETHERNET ONLY .......................... 3-4
FIGURE 3-6 IDU-C PACKAGE CONTENTS - THE IDU-C, 16 E1/T1 PORTS ........................ 3-5
FIGURE 3-7 IDU-C PACKAGE CONTENTS - THE MOUNTING KIT AND DC POWER PLUGS ......... 3-5
FIGURE 3-8 TYPICAL INSTALLATION (WITH EXTERNAL ANTENNA) LEFT: RADWIN 2000 RIGHT: WINLINK 1000 ............................................................................................................3-6
FIGURE 3-9 NEW STYLE IDU-E: REAR PANEL ............................................................3-8
FIGURE 3-10 IDU-C FRONT PANEL ......................................................................... 3-9
FIGURE 3-11 IDU-C FRONT PANEL LEDS ................................................................3-9
FIGURE 3-12 IDU-E FRONT PANEL LEDS .............................................................. 3-10
FIGURE 3-13 IDU-C POWER CONNECTORS ............................................................. 3-11
FIGURE 3-14 BEEP SEQUENCE FOR ANTENNA ALIGNMENT............................................ 3-14
FIGURE 4-1 LAN PORTS ON THE FRONT PANEL OF THE IDU-C.......................................4-3
FIGURE 4-2 PINGING AN UNINSTALLED AND UNCONFIGURED LINK ...................................4-3
FIGURE 4-3 FIRST TIME LOG-ON WINDOW ................................................................4-4
FIGURE 4-4 EXTENDED LOG-ON WINDOW ................................................................. 4-4
FIGURE 4-5 LOG ON WINDOW EXPOSING THE USER TYPES. ........................................... 4-5
FIGURE 4-6 UNSUPPORTED DEVICE MESSAGE ............................................................. 4-7
FIGURE 4-7 UNREACHABLE DEVICE MESSAGE ............................................................. 4-7
FIGURE 4-8 INVALID COMMUNITY STRING MESSAGE ....................................................4-7
FIGURE 4-9 LOGGING ON TO AN OVER-THE-AIR SITE ................................................... 4-8
FIGURE 4-10 OPENING RADWIN MANAGER WINDOW PRIOR TO INSTALLATION - IDU-C ....4-9
FIGURE 4-11 SPECTRUM VIEW - OPENING DISPLAY ON INSTALLED LINK ......................... 4-12
FIGURE 5-1 LINK INSTALLATION WIZARD ................................................................. 5-3
FIGURE 5-2 INSTALLATION WIZARD, SYSTEM DIALOG BOX ............................................ 5-4
FIGURE 5-3 INSTALLATION WIZARD, SYSTEM DIALOG BOX FILLED OUT ............................ 5-5
FIGURE 5-4 CHANGE LINK PASSWORD DIALOG BOX ..................................................... 5-6
FIGURE 5-5 LOST OR FORGOTTEN LINK PASSWORD RECOVERY .......................................5-6
FIGURE 5-6 CHANNEL SETTINGS - AUTOMATIC CHANNEL SELECTION ...............................5-7
FIGURE 5-7 CHANNEL SETTINGS - SHOWING AVAILABLE INSTALLATION RATES ...................5-8
FIGURE 5-8 CHANNEL SETTINGS - SHOWING AVAILABLE CHANNEL BANDWIDTHS ................ 5-8
FIGURE 5-9 TRANSMISSION POWER AND ANTENNA PARAMETERS .................................... 5-9
FIGURE 5-10 ANTENNA CONFIGURATION DIALOG ...................................................... 5-13
RADWIN 2000 User Manual
Release 2.5.40
xviii
FIGURE 5-11 ANTENNA TYPE CHANGE WARNING ....................................................... 5-13
FIGURE 5-12 ANTENNA PARAMETERS CHANGE WARNING ............................................. 5-14
FIGURE 5-13 TX POWER LIMITS .......................................................................... 5-14
FIGURE 5-14 ANTENNAS CONFIGURED FOR TWO DUAL AND TX POWER 5 DBM ................ 5-15
FIGURE 5-15 HSS SETTINGS............................................................................... 5-16
FIGURE 5-16 SERVICES AND RATES - RADWIN 2000 C ONLY .................................... 5-17
FIGURE 5-17 SERVICES AND RATES FOR RADWIN 2000 COLLOCATED AS A CLIENT ......... 5-17
FIGURE 5-18 SERVICES AND RATES FOR MODELS RADWIN 2000 L AND RADWIN 2000 PDH5-18
FIGURE 5-19 SERVICES AND RATES - RADWIN 2000 C MASTER, RADWIN 2000 CLIENTS5-20
FIGURE 5-20 TDM TYPE SELECTION ..................................................................... 5-21
FIGURE 5-21 TDM SERVICE PORT SELECTION .......................................................... 5-21
FIGURE 5-22 TDM SERVICE PORT SELECTION - SEVEN SERVICES SELECTED..................... 5-22
FIGURE 5-23 SERVICES AND RATES - SERVICES CHOSEN ............................................ 5-22
FIGURE 5-24 SERVICES AND RATES DIALOG: AVAILABLE RATES .................................... 5-23
FIGURE 5-25 CHOOSING HOT STANDBY MODE ........................................................ 5-24
FIGURE 5-26 TDM JITTER BUFFER CONFIGURATION ................................................. 5-25
FIGURE 5-27 TDM JITTER BUFFER CONFIGURATION - TBFR EVALUATION BAR ................ 5-26
FIGURE 5-28 SERVICES AND TDM DELAY SET - LINK READY FOR EVALUATION ................. 5-26
FIGURE 5-29 TDM PARAMETERS CONFIGURATION (1)............................................... 5-27
FIGURE 5-30 TDM PARAMETERS CONFIGURATION (2)............................................... 5-28
FIGURE 5-31 TDM PARAMETERS .......................................................................... 5-28
FIGURE 5-32 INSTALLATION WIZARD EXIT SUMMARY ................................................ 5-29
FIGURE 5-33 MAIN WINDOW OF THE MANAGER AFTER INSTALLATION WITH LOADED TRUNKS5-30
FIGURE 5-34 MAIN WINDOW OF THE MANAGER AFTER INSTALLATION WITH ASYMMETRIC CAPACITY ALLOCATION - NO HSS ............................................................................................. 5-31
FIGURE 5-35 MAIN WINDOW OF THE MANAGER AFTER INSTALLATION WITH ASYMMETRIC CAPACITY ALLOCATION - HSS ENABLED ...................................................................................... 5-32
FIGURE 6-1 MAIN WINDOW, WIRELESS LINK IS ACTIVE ..............................................6-2
FIGURE 7-1 LINK CONFIGURATION WIZARD ..............................................................7-3
FIGURE 7-2 CONFIGURATION WIZARD, SYSTEM DIALOG BOX ......................................... 7-4
FIGURE 7-3 CHANNEL SETTINGS DIALOG BOX - AUTOMATIC CHANNEL SELECTION...............7-5
FIGURE 7-4 SEARCHING FOR THE BEST OPERATING CHANNEL ......................................... 7-6
FIGURE 7-5 CHANNEL SETTINGS WITHOUT AUTOMATIC CHANNEL SELECTION .....................7-6
FIGURE 7-6 CHANNEL FREQUENCY OPTIONS............................................................... 7-7
FIGURE 7-7 CHOOSING AN “OTHER” OPERATING CHANNEL FREQUENCY............................ 7-7
FIGURE 7-8 TRANSMISSION POWER AND ANTENNA PARAMETERS .................................... 7-8
FIGURE 7-9 ANTENNA CONFIGURATION DIALOG WITH OPENED TYPE SELECTION .................7-9
FIGURE 7-10 HSS SETTINGS............................................................................... 7-10
FIGURE 7-11 SERVICES AND RATES DIALOG ............................................................ 7-11
FIGURE 7-12 TDM PARAMETERS CONFIGURATION .................................................... 7-12
FIGURE 7-13 CONFIGURATION WIZARD EXIT SUMMARY ............................................. 7-12
FIGURE 7-14 MAIN WINDOW OF THE MANAGER AFTER CONFIGURATION .......................... 7-13
FIGURE 8-1 CONFIGURATION DIALOG BOX ................................................................8-2
FIGURE 8-2 AIR INTERFACE DETAILS ....................................................................... 8-3
FIGURE 8-3 CHANGING THE TRANSMIT POWER ..........................................................8-4
FIGURE 8-4 HSS STATUS .....................................................................................8-5
FIGURE 8-5 MANAGEMENT ADDRESSES - SITE CONFIGURATION DIALOG BOX .....................8-6
FIGURE 8-6 CONFIGURING MANAGEMENT TRAFFIC VLAN SETTINGS .................................8-7
FIGURE 8-7 ENABLE/DISABLE TELNET ACCESS ........................................................... 8-8
FIGURE 8-8 INVENTORY WINDOW ...........................................................................8-8
FIGURE 8-9 AVAILABLE SECURITY FEATURES ..............................................................8-9
FIGURE 8-10 CHANGING THE COMMUNITY STRING.................................................... 8-10
FIGURE 8-11 ALTERNATIVE COMMUNITY DIALOG BOX ................................................ 8-11
FIGURE 8-12 DATE AND TIME CONFIGURATION ....................................................... 8-14
RADWIN 2000 User Manual
Release 2.5.40
xix
FIGURE 8-13 CHANGE DATE AND TIME .................................................................. 8-14
FIGURE 8-14 DATE AND TIME CONFIGURED FROM AN NTP SERVER .............................. 8-15
FIGURE 8-15 BRIDGE, VLAN AND MIR CONFIGURATION............................................ 8-16
FIGURE 8-16 VLAN TAG SETTINGS ....................................................................... 8-18
FIGURE 8-17 BRIDGE CONFIGURATION - SITE CONFIGURATION DIALOG BOX ................... 8-20
FIGURE 8-18 ETHERNET MIR - THROUGHPUT SELECTION ........................................... 8-20
FIGURE 8-19 TDM MHS STATUS ......................................................................... 8-21
FIGURE 8-20 EXTERNAL ALARMS CONFIGURATION .................................................... 8-22
FIGURE 8-21 SITE CONFIGURATION - RESET TO FACTORY DEFAULTS ............................. 8-23
FIGURE 8-22 ALIGNMENT TONE BUZZER STATES ....................................................... 8-25
FIGURE 8-23 TELNET SESSION LOG ON .................................................................. 8-26
FIGURE 8-24 TELNET MANAGEMENT WINDOW.......................................................... 8-27
FIGURE 9-1 GET DIAGNOSTICS DIALOG BOX ............................................................. 9-2
FIGURE 9-2 LOOPBACK CONFIGURATION BOX ............................................................. 9-4
FIGURE 9-3 LOOPBACK CONFIGURATION BOX WITH ONE SITE A PORT SELECTED.................9-4
FIGURE 9-4 LOOPBACK OPTIONS.............................................................................9-4
FIGURE 9-5 LOOPBACK DEFINED .............................................................................9-5
FIGURE 9-6 SITE A PORT 2 SET TO LOOPBACK ........................................................... 9-5
FIGURE 9-7 LOCAL LINE LOOPBACK......................................................................... 9-6
FIGURE 9-8 REMOTE REVERSE LOOPBACK ................................................................. 9-6
FIGURE 9-9 REMOTE LINE LOOPBACK ...................................................................... 9-7
FIGURE 9-10 LOCAL REVERSE LOOPBACK ................................................................. 9-7
FIGURE 9-11 PREFERENCES DIALOG BOX ..................................................................9-9
FIGURE 9-12 BASIC PERFORMANCE MONITORING REPORT .......................................... 9-10
FIGURE 9-13 A TYPICAL PERFORMANCE MONITORING REPORT BASED ON 15 MINUTE INTERVALS9-10
FIGURE 9-14 PERFORMANCE MONITORING REPORT SHOWING THE EFFECT OF A RESET ...... 9-11
FIGURE 9-15 THRESHOLD CONFIGURATION DIALOG BOX ............................................. 9-13
FIGURE 9-16 EVENTS LOG DISPLAY ...................................................................... 9-14
FIGURE 9-17 PREFERENCES DIALOG BOX - EVENT TAB ............................................... 9-16
FIGURE 9-18 ACTIVE ALARMS SUMMARY ................................................................ 9-17
FIGURE 9-19 RECENT EVENTS - UP TO LAST 256 EVENTS AT SITE A ............................ 9-18
FIGURE 9-20 ADVANCED PREFERENCES .................................................................. 9-18
FIGURE 10-1 INTERFERENCE CAUSED BY COLLOCATED UNITS ....................................... 10-2
FIGURE 10-2 COLLOCATED UNITS USING HUB SITE SYNCHRONIZATION (1) .................... 10-2
FIGURE 10-3 COLLOCATED UNITS USING HUB SITE SYNCHRONIZATION (2) .................... 10-2
FIGURE 10-4 HSS INTERCONNECTION UNIT............................................................ 10-3
FIGURE 10-5 HSS WIRING SCHEMATIC .................................................................. 10-4
FIGURE 10-6 HSS SYNC SIGNAL PATH WITH ODU 1 AS HSS MASTER ........................... 10-4
FIGURE 10-7 CASCADING TWO HSS UNITS ............................................................. 10-5
FIGURE 10-8 CASCADING THREE HSS UNITS ........................................................... 10-6
FIGURE 10-9 ODU BEEP FOR HSS ERROR.............................................................. 10-7
FIGURE 10-10 RADIO FRAME PATTERN .................................................................. 10-8
FIGURE 10-11 SERVICES AND RATES - RADWIN 2000 C MASTER, RADWIN 2000 CLIENTS10-9
FIGURE 10-12 SERVICES AND RATES - RADWIN 2000 C MASTER, RADWIN 2000 CLIENTS - EXTREME
ASYMMETRIC ALLOCATION ...................................................................................... 10-10
FIGURE 10-13 HSS SETTINGS: LEFT - WINLINK 1000 CLIENT, RIGHT - RADWIN 2000 MASTER1012
FIGURE 10-14 HUB SITE CONFIGURATION DIALOG - LEFT WINLINK 1000, RIGHT RADWIN 20001014
FIGURE 10-15 SITE CONFIGURATION: HSS - LEFT - WINLINK 1000 CLIENT, RIGHT - RADWIN 2000
MASTER ............................................................................................................ 10-14
FIGURE 10-16 HSS NOT SUPPORTED .................................................................. 10-15
FIGURE 11-1 GSU SCENARIO - INDEPENDENT DISTRIBUTED SITES................................ 11-2
FIGURE 11-2 GSU SCENARIO - COMMUNICATING DISTRIBUTED SITES ........................... 11-2
RADWIN 2000 User Manual
Release 2.5.40
xx
FIGURE 11-3 PHASE SHIFTED TRANSMISSION - PHASE SHIFT IS 1/2 THE RFD ................. 11-3
FIGURE 11-4 MAKE THE GSUS THE FIRST TWO COLLOCATED UNITS .............................. 11-4
FIGURE 11-5 GENERAL GSU CONFIGURATION .......................................................... 11-5
FIGURE 11-6 GSU MAIN WIDOW AT STARTUP ......................................................... 11-6
FIGURE 11-7 SITE CONFIGURATION: SYSTEM .......................................................... 11-7
FIGURE 11-8 SITE CONFIGURATION: GPS SYNC UNIT ............................................... 11-8
FIGURE 11-9 SITE CONFIGURATION: MANAGEMENT .................................................. 11-9
FIGURE 11-10 SITE CONFIGURATION: INVENTORY .................................................. 11-10
FIGURE 11-11 SITE CONFIGURATION: SECURITY .................................................... 11-10
FIGURE 11-12 SETTING THE DATE AND TIME FOR TRAP REPORTING ............................ 11-11
FIGURE 11-13 SITE CONFIGURATION: OPERATIONS ................................................ 11-11
FIGURE 11-14 SITE CONFIGURATION: OPERATIONS ................................................ 11-12
FIGURE 12-1 RADWIN MONITORED HOT STANDBY ................................................. 12-1
FIGURE 12-2 RADWIN Y-CONNECTION PATCH PANEL .............................................. 12-3
FIGURE 12-3 HOW TO CONNECT THE IDUS TO THE PATCH PANEL ................................ 12-4
FIGURE 12-4 SERVICES CONFIGURATION PANEL: HOT STANDBY MODE SELECTION ............ 12-5
FIGURE 12-5 THE PRIMARY LINK UNDER NORMAL OPERATION ...................................... 12-6
FIGURE 12-6 THE SECONDARY LINK UNDER NORMAL OPERATION .................................. 12-7
FIGURE 12-7 PRIMARY LINK A FEW SECONDS BEFORE REGULAR NO-LINK DISPLAY ............. 12-8
FIGURE 12-8 SECONDARY LINK OPERATING AS THE HOT STANDBY LINK ......................... 12-9
FIGURE 12-9 PRIMARY LINK AFTER THE SWITCH OVER TO SECONDARY LINK (AFTER A FEW SECONDS THE
DISPLAY MOVES TO NO-LINK DISPLAY, WITH TDM PORTS GRAYED OUT.) .......................... 12-11
FIGURE 12-10 SECONDARY LINK OPERATING AFTER THE SWITCH OVER TO SECONDARY. (AFTER A FEW
MOMENTS THE TDM ICONS BECOME GREEN.) ............................................................. 12-12
FIGURE 12-11 PRIMARY LINK OPERATING AFTER THE SWITCH BACK FROM SECONDARY ..... 12-13
FIGURE 12-12 SECONDARY LINK OPERATING AFTER THE SWITCH BACK TO PRIMARY ........ 12-14
FIGURE 13-1 RING PROTECTION MECHANISM .......................................................... 13-2
FIGURE 13-2 NODE WITH IDU AND POE DEVICE ..................................................... 13-6
FIGURE 13-3 1+1 ETHERNET .............................................................................. 13-7
FIGURE 13-4 USING IDU-C OR IDU-E WITH POES FOR THE RPL................................ 13-7
FIGURE 13-5 SERVICES WINDOW WITH RING SELECTED ............................................. 13-8
FIGURE 13-6 RING OPTIONS ............................................................................... 13-8
FIGURE 13-7 CONFIGURING RING LAN VIDS .......................................................... 13-9
FIGURE 13-8 CONFIGURING RPL VIDS .................................................................. 13-9
FIGURE 14-1 TWO NETWORK USING THE SAME LINK WITH TAGGING .............................. 14-1
FIGURE 14-2 SEPARATING CLIENT DATA STREAMS USING DOUBLE TAGGING ..................... 14-2
FIGURE 14-3 VLAN TAG SETTINGS ....................................................................... 14-7
FIGURE 14-4 VLAN: INGRESS MODES ................................................................... 14-7
FIGURE 14-5 VLAN: INGRESS MODE - SETTING VLAN ID AND PRIORITY ...................... 14-8
FIGURE 14-6 VLAN: EGRESS MODES .................................................................... 14-8
FIGURE 14-7 UNTAGGING SELECTED VIDS .............................................................. 14-8
FIGURE 14-8 PROVIDER PARAMETERS .................................................................... 14-8
FIGURE 15-1 SOFTWARE UPGRADE UTILITY - MAIN WINDOW ...................................... 15-2
FIGURE 15-2 ADD SITE OPTIONS .......................................................................... 15-2
FIGURE 15-3 ADDING A SINGLE SITE FOR UPGRADE .................................................. 15-2
FIGURE 15-4 SINGLE SITE ADDED FOR UPGRADE ...................................................... 15-3
FIGURE 15-5 SOFTWARE UPGRADE SITE OPTIONS ..................................................... 15-3
FIGURE 15-6 SOFTWARE UPGRADE IN PROGRESS - NOTE THE STOP BUTTON ................... 15-4
FIGURE 15-7 SOFTWARE UPGRADE COMPLETED SUCCESSFULLY ..................................... 15-4
FIGURE 16-1 ACTIVATING AN ODU - INACTIVE LINK ................................................. 16-2
FIGURE 16-2 AIR INTERFACE DIALOG BOX .............................................................. 16-2
FIGURE 16-3 THE LOCAL ODU AFTER ACTIVATION - PROBING ..................................... 16-3
FIGURE 16-4 BOTH SITES ACTIVATED AND AWAITING CONFIGURATION ........................... 16-4
FIGURE 16-5 CHANNEL SELECT DIALOG BOX - ACS PERMANENTLY ENABLED .................... 16-5
RADWIN 2000 User Manual
Release 2.5.40
xxi
3
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
16-6
17-4
17-5
17-6
17-7
18-1
18-2
18-3
18-4
18-5
18-6
19-1
19-2
19-3
19-4
19-5
19-6
19-7
19-8
20-1
20-2
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
20-3 CHANGE BAND DIALOG ..................................................................... 20-3
20-4 A DIFFERENT BAND SELECTED............................................................. 20-4
20-5 CHANGE BAND CONFIRMATION ........................................................... 20-4
20-6 MAIN WINDOW AFTER BAND CHANGE - NEW BAND CIRCLED ....................... 20-5
20-7 USING THE OPERATIONS WINDOW TO ENTER A LICENSE KEY ...................... 20-6
21-1 FRESNEL ZONE ............................................................................... 21-4
21-2 ACCESSING THE LINK BUDGET CALCULATOR .......................................... 21-5
21-3 LINK BUDGET WINDOW .................................................................... 21-5
21-4 BAND SELECTOR ............................................................................. 21-6
21-5 RADWIN 2000 SERIES SELECTOR ...................................................... 21-7
21-6 RADWIN 2000 CHANNEL BANDWIDTH SELECTOR .................................. 21-7
21-7 RFP SELECTOR .............................................................................. 21-8
21-8 RFP SELECTION GUIDE .................................................................... 21-8
21-9 RATE SELECTOR .............................................................................. 21-9
21-10 CALCULATION OF DISTANCE FROM SITE COORDINATES ......................... 21-10
21-11 CLIMACTIC C FACTORS ................................................................. 21-11
21-12 CLIMACTIC C FACTOR DESCRIPTION ................................................. 21-12
21-13 WORLD MAP SHOWING C FACTOR CONTOURS ..................................... 21-12
21-14 LBC - RESULTS SECTION .............................................................. 21-13
22-1 PREFERENCES: QUICK INSTALL ........................................................... 22-2
22-2 NEW INSTALL MODE BUTTON FOR QUICK INSTALL MODE .......................... 22-2
22-3 CHANGE TO INSTALLATION MODE CAUTIONARY MESSAGE .......................... 22-3
22-4 SERVICE MODE BUTTON TO RESUME LINK SERVICE TRAFFIC ....................... 22-3
22-5 RESUMPTION OF SERVICES CAUTIONARY MESSAGE ................................... 22-3
23-1 STARTING THE ANALYSIS ................................................................... 23-1
23-2 SITE A (MANAGING SITE) DONE .......................................................... 23-2
23-3 SITE B (OVER- THE-AIR SITE) DONE, SHOWING CURRENT CHANNEL ............. 23-3
23-4 RADWIN 2000 SPECTRUM VIEW - ANNOTATED DISPLAY ......................... 23-4
23-5 MOUSE POINTER ACTIVE FOR ZOOMING ................................................ 23-5
23-6 SELECTING AN AREA OF INTEREST TO ZOOM WITH THE RIGHT MOUSE BUTTON DOWN23-
FCC/IC 5.4/5.3 GHZ OPERATIONAL ................................................... 16-6
MOUNTING ON A POLE ..................................................................... 17-2
MOUNTING ON A WALL .................................................................... 17-3
MOUNTED ODUS WITH CORRECT “WATER NOSE” .................................... 17-4
INCORRECTLY MOUNTED ODU (NO “WATER NOSE”) ................................ 17-4
GROUNDING ANTENNA CABLES ............................................................ 18-2
GROUNDING A TYPICAL POLE INSTALLATION ........................................... 18-4
GROUNDING A TYPICAL WALL INSTALLATION .......................................... 18-5
ODU SURGE SUPPRESSOR AND GROUNDING .......................................... 18-5
TRANSTECTOR’S SURGE SUPPRESSOR ................................................... 18-6
SURGE SUPPRESSOR AND GROUNDING AT BUILDING ENTRY POINT ............... 18-7
LOG ON WINDOW FOR LOCAL CONNECTION........................................... 19-2
OPENING RADWIN MANAGER WINDOW PRIOR TO INSTALLATION ............... 19-3
CONFIGURATION DIALOG BOX ............................................................ 19-3
MANAGEMENT ADDRESSES - SITE CONFIGURATION DIALOG BOX ................. 19-4
ODU WITH IP ADDRESSING CONFIGURED ............................................. 19-4
CONFIRMATION OF IP ADDRESS CHANGE .............................................. 19-4
MAIN WINDOW AFTER IP ADDRESS CHANGE .......................................... 19-5
EXISTING IP ADDRESS DISPLAYED AFTER LOG-ON WITH LOCAL CONNECTION . 19-6
BECOMING INSTALLER ...................................................................... 20-2
OPENING RADWIN MANAGER WINDOW PRIOR TO BAND CHANGE (DEFAULT CIRCLED)20-
FIGURE 23-7 REQUESTED
SECTION ZOOMED ............................................................ 23-6
RADWIN 2000 User Manual
Release 2.5.40
xxii
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
23-8 SPECTRUM VIEW SYSTEM MENU .......................................................... 23-7
23-9 EFFECT OF SETTING SHOW MAX ......................................................... 23-7
23-10 EFFECT OF SETTING SHOW AVERAGE.................................................. 23-7
23-11 FURTHER VIEWING OPTIONS............................................................. 23-8
23-12 ANTENNA A SELECTED .................................................................... 23-8
23-13 SPECTRUM VIEW CSV FILE IMPORTED INTO MS EXCEL ......................... 23-10
24-1 BRS/EBS BANDS SCHEMATIC ............................................................ 24-2
25-1 SERVICES WINDOW WITH QOS SELECTED .............................................. 25-2
25-2 ETHERNET QOS CONFIGURATION - MODE SELECTION .............................. 25-2
25-3 TOP: VLAN ALLOCATION. BOTTOM: DIFFSERV ALLOCATION....................... 25-3
25-4 MIR CHOICE - PER QUEUE................................................................. 25-4
B-1 EXAMPLE FOR CONNECTING THE ALARM CONNECTOR ....................................B-4
D-1 TOP LEVEL SECTIONS OF THE PRIVATE MIB............................................. D-3
D-2 PRODUCT MIB: LEFT WINLINK 1000, RIGHT RADWIN 2000 .................... D-3
G-4 MONTAGE SUR UN PYLÔNE ................................................................... G-4
G-5 MONTAGE SUR UN MUR ....................................................................... G-5
RADWIN 2000 User Manual
Release 2.5.40
xxiii
RADWIN 2000
Broadband Wireless Transmission System
USER MANUAL
RELEASE 2.5.40
Part 1: Basic Installation
UM 2000-2540/02.11
Chapter 1
Introduction
Welcome to RADWIN 2000!
RADWIN 2000 is a portfolio of carrier-class wireless broadband radios in the sub-6 GHz range.
These radios offer unmatched performance and robustness.
The RADWIN 2000 portfolio consists of three product series:
•
RADWIN 2000 C - Series supporting 100 Mbps symmetric (full duplex and asymmetric) throughput and up to 16 E1s/T1s
•
RADWIN 2000 L - Series supporting 50 Mbps symmetric (full duplex) throughput and
up to 16 E1s/T1s
•
RADWIN 2000 PDH - Series supporting 16 E1s/T1s and 10 Mbps Ethernet (Note that
this model may only be used with an IDU-C or IDU-E. It cannot be used with a PoE
device.)
•
RADWIN 2000 X - Series supporting 3 E1s or 4 T1s and 10Mbps capacity (net
throughput, full duplex)
RADWIN 2000 highlights:
•
High capacity (up to 100Mbps full duplex net throughput)
•
Native TDM transport up to 16 E1/T1 ports
•
Multi-band products for maximum flexibility
•
Advanced air-interface based on MIMO, antenna Diversity and OFDM technologies
•
Superior range performance
•
Simple installation and management
•
High Tx power of 25dBm
•
Support for 10MHz, 20MHz and 40MHz channel bandwidths
•
Monitored Hot Standby (1+1) for TDM services
•
Ring Topology (including 1+1) for Ethernet service
•
QoS support
•
Separate management and Ethernet traffic VLAN support
•
GSU support for distributed hub sites
•
Hub Site Synchronization
RADWIN 2000 User Manual
Release 2.5.40
1-1
What’s new in Release 2.5.40
Chapter 1
The RADWIN 2000 radio series supports the 4.8 - 6 GHz, 2.4 GHz and 3.4 - 3.7 GHz spectrum
bands, and complies with international standards and regulations (FCC, IC Canada, ETSI and
WPC India). DFS is supported where required by regulation.
What’s new in Release 2.5.40
The main changes in release 2.5.40 from release 2.5.30 are:
»
»
The new RADWIN 2000 X series addressing corporate Access needs
»
RADWIN 2000 C support for the 2.5 GHz band according the BRS (FCC/IC) regulation.
Further support for frequencies in the 3.x bands forRADWIN 2000 C and RADWIN
2000 X
Details are set out in Table 1-1 below.
Terminology
•
3.X Universal bands refer to RADWIN Universal bands as described above.
•
3.X or 3.X GHz refers to the frequency range 3.3 – 3.8GHz
•
BRS refers to the 2.5 GHZ band subject to the FCC BRS regulations
•
A 3.X ODU is an ODU pre configured to operate in the 3.X GHz licensed bands
•
A 3.X Link in a RADWIN 2000 link using a pair of 3.X ODUs
•
High Resolution Bands - Channel minimum step is 250 KHz. Applies to 3.475 3.650 GHz IC RSS-192, 3.4 -3.7 GHz ETSI and the 3.3 - 3.8 GHz Universal band.
•
Low Resolution Bands - Channel minimum step is 1 MHz. Applies to FCC regulations in the 3.650-3.675 GHz band.
More About New and Extended RADWIN 2000 Products
RADWIN 2000 C-series 3.X Products
The new RADWIN 2000 C-series 3.X products are intended for IP and TDM backhaul applications. Integrated and connectorized products are available. The products are multiple band
with default bands as shown in Table 1-1 below.
These products are broadly compatible with all features set of RADWIN 2000 with the following differences:
•
The 3.X products support 5, 10 and 20 MHz channel bandwidths.
•
Note
•
The 5 Mhz channel bandwidth is supported under Licensed bands
only
40MHz channel bandwidth is not supported under 3.X GHz products.
•
Channel minimum step under the band 3.650-3.675 GHz is 1 MHz. ACS and Spectrum
View are supported (Low Resolution Bands).
•
Channel minimum step under 3.4-3.7 GHz Universal ,3.475-3.650 IC RSS-192 and 3.4
-3.7 GHz ETSI is 250KHz. ACS and Spectrum View are not supported (High Resolution
Bands).
•
All products in this series support both Ethernet and TDM services
RADWIN 2000 User Manual
Release 2.5.40
1-2
More About New and Extended RADWIN 2000 Products
Chapter 1
Otherwise, all other features of release 2.5.00 related to RADWIN 2000 C Products are supported.
RADWIN 2000 C-series BRS Products
In principle, there is no difference between working under BRS and any other FCC regulatedband. You do need to know how to choose the correct channel. Further information about
BRS may be found in Chapter 24.
RADWIN 2000 X-series for 3.X Products
The new RADWIN 2000 X-series for 3.X products are intended for Access applications. The
series diffesr from the RADWIN 2000 C-series 3.X products in that it is limited to 10 Mbps full
duplex net throughput and only supports 5 MHz channel bandwidth.
Summary.
Table 1-1: Summary: Frequencies for RADWIN 2000 C and RADWIN 2000 X Series
RADWIN
2000
Series
Channel
Bandwidth Capacity (Mbps)
(MHz)
Frequency bands
TDMs
FCC part 90 subpart Z and IC RSS-197
supporting 3.650-3.675 GHz
FCC part 27 named as BRS, supporting 2.52.7 GHz band
C-Series
No change
5/10/20
100, aggregate net
throughput
16
IC RSS-192 supporting 3.475 – 3.650 GHz
New product
No change
ETSI 3.4 -3.7 GHz (*)
5/10/20
100, aggregate net
throughput
16
No change
Universal 3.3-3.8 GHz
5/10/20
100, aggregate net
throughput
16
Extends existing
product
10, full duplex net
throughput
4 T1s/
3 E1s
New product
Universal 3.3-3.8 GHz
10, full duplex net
throughput
4 T1s/
3 E1s
New product
ETSI 3.4 -3.7 GHz(*)
10, full duplex ne
throughput
4 T1s/
3 E1s
New product
FCC part 90 subpart Z and IC RSS-197
supporting 3.650-3.675 GHz
IC RSS-192 supporting 3.475– 3.650 GHz
X-Series
Notes
•
•
Table 1-1 applies both to integrated and connectorized ODUs.
(*) ETSI uses a split band as follows.
1. 3.403-3.490 GHz up to 16 dBm
Note
2. 3.470-3.610 GHz up to 23 dBm
3. 3.590-3.710 GHz up to 25 dBm
See also page 20-9.
RADWIN 2000 User Manual
Release 2.5.40
1-3
Key Applications
Chapter 1
Key Applications
Cellular Backhaul
RADWIN 2000 products enable cellular carriers to expand their networks in both urban and
rural areas quickly and cost-effectively.
RADWIN 2000 and specifically RADWIN 2000 PDH systems are ideally suited for a broad
range of cellular backhaul deployment scenarios; they empower carriers to expand their presence into remote and low ARPU areas, provide enhanced overlay coverage in urban spots,
and can serve as a temporary or backup backhaul solution.
Figure 1-1: Typical Cellular Backhaul application
Broadband Access
With RADWIN 2000 solutions, service providers can expand their service footprint rapidly and
affordably, providing high-capacity services that match the ever-growing demand for highquality, high-speed broadband.
RADWIN 2000 is the ideal solution for last mile access, for large corporations requiring high
capacity either or both IP or TDM traffic.
Figure 1-2: Typical Broadband Access application
RADWIN 2000 User Manual
Release 2.5.40
1-4
Mobility Applications
Chapter 1
Figure 1-3: Typical WiFi Backhaul Application
Mobility Applications
RADWIN 2000 radios have been successfully deployed in a variety of Mobility Applications:
Border Control
RADWIN 2000 may be used in both towers and patrol vehicles to provide live video surveillance. Handoff from tower to tower as the patrol vehicles moves along the patrol road is
seamless. The towers may be sited several kilometers apart (depending on topography) and
are themselves synchronized using RADWIN GSU.
Installation Security
Securing an installation like a factory or an airport is broadly similar to Border Control, however the distance are smaller and the towers may be connected to a control room using
cables.
Railway solutions
This is a relatively new application and includes for example,
»
»
»
On-board surveillance
On-board monitoring and control
Passenger services including Internet access
For further information about Mobility Applications, contact RADWIN Customer Support.
Key Features of RADWIN 2000
Some of the outstanding features of the RADWIN 2000 radio series are as follows:
»
E1/T1 + Ethernet in one Solution
RADWIN 2000 systems deliver carrier-class native E1/T1 + Ethernet in a single platform, making them ideal for a range of backhaul and access applications. Up to 16 E1/
T1 services are supported for C, L and PDH models.
»
High Capacity
The RADWIN 2000 system provides a high-capacity link of 100 Mbps net throughput
full duplex
»
Superior Spectral Efficiency
RADWIN 2000 User Manual
Release 2.5.40
1-5
Key Features of RADWIN 2000
Chapter 1
Built on advanced MIMO and OFDM technologies, the RADWIN 2000 system provides
a high-capacity link at channel bandwidths of 5, 10 and 20MHz. These channel
bandwidths supports high robustness of the air interface under interference and harsh
conditions.
»
Multi-band Products
Every RADWIN 2000 Multi-band radio supports multiple frequency bands. For example
the RW-2050-0250 connectorized radio supports the bands: 5.9 GHz, 5.8 GHz, 5.4
GHz, 5.3 GHz, 4.9 GHz, 2.4 GHz and 3.4-3.7 GHz. The RADWIN 2000 Multi-band products support the regulations of FCC, IC Canada, ETSI and WPC India. DFS is supported where required by regulation.
»
Advanced Air Interface
The RADWIN 2000 system provides an advanced air-interface based on MIMO,
antenna diversity and OFDM technologies, resulting in an exceptionally robust air
interface and high frequency band granularity.
Using the following technologies, the RADWIN 2000 air interface is designed to ensure
nonstop, high quality transmission, even under interference and harsh conditions:
»
•
Automatic Adaptive Rate (AAR) is a mechanism that dynamically adapts the air
interface rate by changing both the signal modulation and coding.
•
Automatic Channel Selection (ACS) chooses the best channel by monitoring the
available radio channels and dynamically selecting a channel which is best suited
for transmission at any given time.
•
Automatic Repeat Request (ARQ) is a mechanism for error control during data
transmission. When the receiver detects an error in the received information, it
automatically requests the transmitter to resend the information. This process is
repeated until the transmission is error free or the error continues beyond a predetermined number of maximum transmissions. RADWIN 2000's ARQ mechanism
is optimized for time-critical traffic.
•
Forward Error Correction (FEC) with very low overhead and algorithms specifically designed for the varying conditions of license-exempt frequency bands,
ensuring fast, robust and error-free communications.
High transmission (Tx) power
The RADWIN 2000 system supports high Tx power, compliant with radio regulations.
High Tx power increases the system's availability and range, and enables the high
performance with smaller antennas, thus reducing the total cost of the solution (lower
CAPEX), installation and tower rent costs (lower OPEX).
The 5 GHz bands support a maximum Tx power of 25dBm whereas the 2.4 GHz band
supports a maximum Tx power of 26dBm.
»
Superior range performance
The RADWIN 2000 system supports high capacity at superior ranges. The Link Budget
Calculator (Chapter 21) is used to determine the capacity and range according to the
choice of product, antenna, type of service and environmental conditions.
»
HSS Interoperability between RADWIN 2000 and WinLink 1000
Site Synchronization is supported with any mix of RADWIN 2000 and WinLink 1000
links. RADWIN 2000 can be used to backhaul WinLink 1000 collocated links without
mutual interference
RADWIN 2000 User Manual
Release 2.5.40
1-6
Key Features of RADWIN 2000
»
Chapter 1
Monitored Hot Standby (1+1):
The RADWIN Monitored Hot Standby (MHS) protects up to sixteen E1/T1 services with
RADWIN 2000 and up to four E1/T1 services with WinLink 1000. It is designed to
provide high reliability high-capacity Point-to-Point Links. The RADWIN MHS is •
Designed to provide redundancy and high reliability for carrier class operators
•
Optimized for high capacity links operating in license-free bands
•
A comprehensive solution providing protection against both equipment failure
and loss of air interface, by simple connectivity between a primary link and a secondary link
•
Able to use a different band for maximum protection to the air interface
The main features of the RADWIN MHS are –
•
Cut-over from the primary to the secondary link completely automatic
•
Cut-over time no more than 50 ms
•
Automatic restore to primary link as soon as it becomes available
•
WinLink 1000 can backup a RADWIN 2000 link
A major benefit of RADWIN MHS is that is can underpin an affordable Service Level
Agreement structure by protecting part of the RADWIN 2000 trunks with WinLink
1000.
MHS supports TDM services; Ethernet services are carried by both links independently.
»
Spectrum View
Spectrum View displays a visual representation of spectrum availability during the
link installation. It is an RF survey tool supporting the link installation prior to service
activation.
Use Spectrum View to assist you to choose the operating channel.
»
Diversity
RADWIN 2000 links using dual bipolar antennas may be configured to transmit the
same data through both radios. This feature provides added data transmission integrity under harsh conditions.
»
Simple installation and management
RADWIN 2000 systems are extremely simple to install and maintain. They are typically
up and running in less than an hour.
The RADWIN Manager application has full local and remote management capabilities.
The user-friendly SNMP based management tool provides full end-to-end
configuration, event logging, and performance monitoring capabilities.
»
Enhanced Security
The security features of RADWIN 2000 include:
•
RADWIN 2000's AES 128-bit integrated advanced encryption support provides
enhanced air interface security for carriers and private networks. It ensures user
data protection with one of the most sophisticated commercially available combined encryption and authentication techniques, CCM/AES. This technique combines message authentication (preventing anti-spoofing and replay protection)
with commercial encryption, and complies with the IEEE 802.11i (phase iii) security recommendations.
RADWIN 2000 User Manual
Release 2.5.40
1-7
Components of a RADWIN 2000 Link
Chapter 1
CCM/AES uses a symmetric 128-bit encryption key (EK), and a nonce, and provides both message encryption and authenticating signature. The nonce mechanism enables the receiver to remember already received genuine messages and
reject all replayed messages.
»
•
Initial encryption and authentication is based on a user-defined master key (Link
Password). While standard Wireless LAN encrypts only the Ethernet Payload, the
AES encrypts both the source and destination MAC addresses.
•
In addition to normal log on access, Read or Write Community access is available
at log on
•
Link Lock is a part of the RADWIN 2000 security concept. It is designed to discourage physical theft of units and “piggybacking” using an otherwise identical
ODU to steal bandwidth or information. It locks a pair of synchronized ODUs for
mutually exclusive communication.
SFP support in the IDU-C
Standard SFP modules are used, enabling any type of Ethernet physical connectivity
including various fiber connections. E3/T3 or E1/T1 over Ethernet SFPs can be used as
well.
»
»
»
Separate management and traffic VLAN support
Ethernet Ring Topology
QoS Support (RADWIN 2000 C based links)
QoS enables Operator and Service Providers to offer delay-sensitive services such as
VoIP, IP-TV, time critical applications and online games.
Components of a RADWIN 2000 Link
The Outdoor Unit (ODU)
The Radio Outdoor Unit (ODU)
The ODU is the radio transceiver of the RADWIN 2000 system. It supports two antennas for
MIMO operation. It is available with an integrated antenna (Integrated Antenna ODU) or
with connectors for an external antenna (Connectorized ODU).
The ODU may be mounted on a pole or a wall, and connects to the IDU or PoE device using a
CAT5e cable.
RADWIN 2000 User Manual
Release 2.5.40
1-8
The Indoor Unit (IDU)
Chapter 1
The ODU comes in two form factors as shown in Figure 1-4 below:
Rear
Integrated Antenna
Connectorized
Front
Figure 1-4: ODU Form Factors
•
Integrated Antenna ODU
This ODU has an integrated 370mm (1.2ft) flat panel antenna. The ODU contains both
the radio and the antenna as a single unit housed in a weatherproof case.
•
Connectorized ODU
This ODU has 2xN-type connectors for connecting an external antenna.
See the RADWIN Product Catalog for the range of ODU products available
in release 2.5.40.
The external antenna choices are:
Note
•
•
•
Single bipolar antenna
Two monopolar antennas
Single monopolar antenna
The Indoor Unit (IDU)
The IDU has the service ports and provides aggregation of these services towards the ODU
that transports them over the air. The IDU also provides power to the ODU.
RADWIN 2000 User Manual
Release 2.5.40
1-9
The Indoor Unit (IDU)
Chapter 1
New style IDU-E for both WinLink 1000 and RADWIN 2000
The new style IDU-E is a carrier grade, compact, half 19 inch wide, 1U plastic unit, providing
up to two Ethernet ports and up to two E1/T1 interfaces. It offers Layer 2 support for Ethernet service and HSS support for collocated links. It is a low cost unit intended for both Access
applications and Enterprise use.
Figure 1-5: New style IDU-E - front view (Note new HSS LED on the left)
The IDU-E rear panel (right to left) has a 25 pin Dry Contact Alarms port. the two (or no)
trunk ports, two LAN ports, an ODU port and finally a 3 pin DC power plug identical to that
used on the IDU-C.
Figure 1-6: New style IDU-E: Rear panel
IDU-C
The IDU-C is a carrier-class 19 inch, 1U unit, providing E1/T1 ports, Ethernet ports,
an SFP port, a STANDBY port for MHS control, dry contact alarms and indication
LEDs. It has two DC power feed connectors. An AC to DC converter is available for
powering the IDU-C from an AC source. The IDU-C is designed to be rack mounted.
Four IDU-C products are available in release 2.5.40 with 16, 8 and 4 E1/T1 ports and with
Ethernet only ports.
Figure 1-7: IDU-C, Ethernet only, front panel
RADWIN 2000 User Manual
Release 2.5.40
1-10
Power Over Ethernet (PoE) Devices
Chapter 1
Figure 1-8: IDU-C, 16 E1/T1 ports, front panel
Power Over Ethernet (PoE) Devices
Basic PoE Device
The basic PoE device provides Ethernet service only,
with power for the ODU. The PoE device is extremely
compact, having one Ethernet port, one ODU port and
a standard 3 pin male AC power socket.
It may be used with both WinLink 1000 and RADWIN
2000 radios.
Figure 1-9: Basic PoE device - showing the radio
Ethernet port
Outdoor (Ruggedized) DC PoE Device
This unit may be used with both WinLink 1000 and RADWIN
2000 radios.
Figure 1-10: Ruggedized DC-PoE Device: Input is -20 to -60 VDC (single input)
GSU
The GPS-based synchronization unit (GSU) is designed to handle inter-site interferences
under large-scale deployment scenarios.
The GSU is an outdoor unit consisting of a standard WinLink 1000 enclosure, a GPS antenna
and a PoE device.
RADWIN 2000 User Manual
Release 2.5.40
1-11
Antennas
Chapter 1
The GSU is connected to the HSS Unit using a standard HSS cable. It synchronizes the transmission timing of multiple Hub-Sites to the same clock source thus eliminating mutual interference (see Chapter 11).
Figure 1-11: General GSU configuration
Antennas
An antenna is the radiating and receiving element from which the radio signal, in the form of
RF power, is radiated to its surroundings and vice versa. The antenna gain and transmitting
power may be limited by country regulations.
The RADWIN 2000 may be operated with an integrated antenna that is part of the ODU unit,
or with external antennas connected to the ODU via N-type connectors. All cables and connections must be connected correctly to reduce RF losses. The required antenna impedance
is 50Ω.
The 5.x GHz Integrated Antenna ODU is provided with 370 mm (1.2ft) flat panel antenna,
with a gain of 23dBi (5.x GHz) / 19dBi (4.9 GHz) and 8° beam width. The 2.x GHz Integrated
Antenna ODU is provided with 370 mm (1.2ft) flat panel antenna, with a gain of 16dBi and
16° beam width. The radio and the antenna are housed in a weatherproof case as a single
unit.
RADWIN 2000 User Manual
Release 2.5.40
1-12
RADWIN Manager
Chapter 1
Figure 1-12: ODU with integrated Flat Panel antenna
External antennas are available for the RADWIN 2000 radios, varying in operating frequencies, form factor, size and gain, dual or single polarization.
The Flat Panel antenna shown below can be used either as an integrated or external antenna.
Figure 1-13: External Antennas for use with RADWIN 2000
See the RADWIN products catalog for RADWIN offering of external antennas. External antennas are also available from third party antenna vendors.
RADWIN Manager
The RADWIN Manager is an SNMP-based management application which manages a complete link over a single IP address. It can also manage each side of the link separately.
The RADWIN Manager application facilitates installation and configuration of the link between
the ODU units. The intuitive, easy-to-use RADWIN Manager has a graphical Microsoft Windows interface, and can be run locally and remotely.
The RADWIN Manager provides:
•
Installation Wizard
•
Frequency band selection
•
On-line monitoring of air interface quality allowing the administrator to monitor the
service and status of each link
RADWIN 2000 User Manual
Release 2.5.40
1-13
RADWIN Network Management System (RNMS)
Chapter 1
•
On-line monitoring of equipment alarms and QoS
•
Local and remote loopback testing
•
Configuration Wizard and site settings
•
Integrated software upgrade utility
•
On-line user manual and help files
•
Link Budget Calculator for calculating the expected performance of the RADWIN 2000
wireless link and the possible service configurations for a specific link range.
The RADWIN Manager can easily be integrated with any SNMP based NMS system.
Figure 1-14: RADWIN Manager window
RADWIN Network Management System (RNMS)
The RADWIN Network Management System enables Service Providers to manage all RADWIN
links in their network from a Network Operations Center (NOC).
Using RNMS, Service Providers can configure and monitor up to 10,000 RADWIN links. The
intuitive easy-to-use RNMS provides a full range of network surveillance, monitoring, configuration and fault management capabilities. It offers users complete visibility and control over
their RADWIN-based networks.
Accessories
RADWIN provides a variety of accessories to support the RADWIN 2000 system:
•
PoE devices
•
AC Power Adaptors
•
External Lightning Protection Units
•
Cables to connect the various system elements
•
Grounding cables
RADWIN 2000 User Manual
Release 2.5.40
1-14
Chapter 1
Documentation supplied with RADWIN 2000
The technical documentation supplied with a RADWIN 2000, is located on the product CD. It
includes the following items:
•
A Quick Installation Guide for experienced installers (also hardcopy)
•
A full User Manual - the document which you are reading
•
A Help file accessible from the RADWIN Manager
•
Link Budget Calculator
How to Use this Manual
This User Manual is divided into three functionally distinct sections reflecting the activities
required to set up a RADWIN 2000. The division is shown in the following table:
Table 1-2: User Manual - General layout
Section
General Content
Purpose
Basic Installation
Core information to install and operate a link
Advanced Installation
Specialized installation techniques
Technical Information
Background for advanced use
The Basic Installation section is divided into functionally distinct chapters reflecting the activities required to set up a RADWIN 2000. The division is shown in the following table:
Table 1-3: User Manual layout
Chapter/
Appendix
Subject
Audience
Site Preparation
Site survey team
Hardware Installation
Field technician
Getting Started with the
RADWIN Manager
Installation technician
Installing the Link
Installation technician
The RADWIN Manager:
Main Window
Installation technician, System manager
Configuring the Link
Installation technician, System manager
Site Configuration
Installation technician, System manager
Monitoring and Diagnostics
Installation technician, System manager
RADWIN 2000 User Manual
Release 2.5.40
1-15
A Little Terminology
Chapter 1
A Little Terminology
In the field, a link typically has a local or headquarters site as for example in Figure 1-1
above. Here the service provider is the local or headquarters site. The service recipient is the
remote site.
Where the link is completely internal to a corporation, the choice of the local and remote is
just a matter of convenience.
A link then, consists of two sites.
In Broadband Wireless terminology, the local and remote sites are sometimes referred to as
“near” and “far”, “HQ” and “remote” and so on.
The site which is closer to the network core (often the local site) will be referred to as site A,
and the opposite side of the link, usually closer to the end user, as site B.
This choice is application-neutral and will be used throughout the manual both to describe the
sites and their names as in the examples.
The link is configured and managed using a PC, the managing computer connected to site
A. (The precise requirements for the managing computer are set out on page 4-1).
We will occasionally need to distinguish between the site to which the managing computer is
connected, and the second site, when they are not necessarily A or B. The former will be
called the managing site and the latter, the over-the-air site. Which is which, is always
determined by the location of the managing computer.
RADWIN 2000 supports three connection methods for the managing computer:
•
Local - a direct peer to peer connection between the Ethernet ports on the managing
computer and the IDU or PoE device. Local connection is always read-write.
•
Network - the managing computer and the site A IDU or PoE device belong to a LAN
and communicate through a router or switch
•
Over-the-air - the managing computer connects to site B via the air interface
•
The managing computer may be connected to the link through an IDU or a PoE
device. In what follows, where ever we refer to an IDU it includes PoE devices unless
stated otherwise. Typically, if we need to refer to an IDU as such, we will use a model
name such as IDU-C.
The terms uplink and downlink, originate from the field of Satellite communications. In a
backhaul or ISP context, uplink is from the user to the network and downlink is from the
network to the user.
RADWIN 2000 User Manual
Release 2.5.40
1-16
Conventions Used in this Manual
Chapter 1
Conventions Used in this Manual
Notifications
Notifications consist of Notes, Cautions and Warnings.
The purpose of a Note is to
•
•
•
•
Note
•
•
•
•
•
Caution
Warning
Draw your attention to something that may not be obvious or counter-intuitive
Emphasize a special feature or peculiarity of the RADWIN 2000
Offer an external reference for additional information
Add a caveat that would not qualify as a full Caution or Warning (see
below)
Provide additional background to what follows
Offer a recommendation
Highlight an indication of something to watch out for
Advise you if an action has “side effects” i.e. it may disturb something
else that would be best left undisturbed
Remind you of something that should be kept in mind
A Caution is a notification of risk of damage to equipment or of service
degradation
A Warning is a notification of risk of danger to persons operating near the
equipment
Typographical conventions
General
Where a term is defined or introduced for the first time, it is shown in Boldface. You will have
noticed this usage in the Terminology section above.
Software
The RADWIN Manager is a Microsoft Windows application following the user interface conventions of familiar Microsoft Windows programs.
We would describe the chain of menu commands indicated in the navigation example of
Figure 1-15 like this,
Tools|Active Alarms|1 A
using Boldface for the menu labels and vertical bars to separate them.
RADWIN 2000 User Manual
Release 2.5.40
1-17
Windows Terminology
Chapter 1
Figure 1-15: Menu navigation in the RADWIN Manager
Similarly, mouse click items will be referred to like this:
“Click Next to continue.”
(A mouse click always uses the left mouse button unless stated otherwise.)
Windows Terminology
Look at Figure 1-1 above. The main application display which you see consists of a framewindow with a menu bar, system icons and content. It will be referred to as a window, the
main window or the Manager window depending on context.
The top line of icons is the tool bar, and provides part of the menu bar functionality with a
mouse click.
At the bottom of the window is the status bar, a line of icons and text boxes.
The central part of the main window consists of several panes: On the right, there are Radio
Interference, Ethernet Service and the Frequency panes. The left hand pane (with the blue
background) is split into three sub-panes.
If you click Site A or Site B in the tool bar, you will be offered another window, which in turn
displays on of several panels depending on which function you choose.
RADWIN 2000 User Manual
Release 2.5.40
1-18
Viewing and Printing
Chapter 1
Figure 1-16: Site Configuration window with open Management panel
Viewing and Printing
This manual is optimized for viewing online as a PDF file. To this end it uses an 11 point
Tahoma typeface for main text. Tables for most part, use 7 or 8 point fonts. Here are a few
pointers for hard-copy printing:
•
The text and table typefaces used are large enough to print the manual at two pages
per sheet
•
For good legibility, use a commercial grade laser printer. A color printer is of course
best, however a monochrome printer set to use gray-scale gives acceptable results
•
Better quality inkjet printers also give good output
RADWIN 2000 User Manual
Release 2.5.40
1-19
Chapter 2
Site Preparation
Planning the Link Site
Overview
Link site planning consists of a set of surveys, which must be carried out before any equipment is brought to the site. If for some reason, the outcome of any of these surveys is negative, site re-location will need to be considered.
A Site Survey consists of three stages:
1. Preliminary survey - The proposed link is analyzed in the office using a topographic map.
2. Physical survey - The locations of the indoor and outdoor equipment are determined onsite.
3. Radio Frequency (RF) survey - It is recommended that the installation area be scanned
with a spectrum analyzer, to identify RF interference so as to determine a clear channel for
radio installation (on-site).
The Site Survey
Introduction
RADWIN wireless links must be planned before installation. The designated installation site
must be appraised to determine that the wireless system is able to operate efficiently and
provide connectivity without signal degradation.
RADWIN 2000 offers a wide operating frequency range. A free frequency channel must be
determined within the operating range, for optimum performance.
Recommended Equipment
Stage 1: Preliminary Survey
•
Topological map of the area
•
Urban map of the area
•
Compass
Stage 2: Physical Survey
•
100 meter tape measure
RADWIN 2000 User Manual
Release 2.5.40
2-1
Stage 1: Preliminary Survey
Chapter 2
•
Ohmmeter, to check ground connection
•
Binoculars
•
Map
•
Digital camera
•
Paper, pencil, and a clipboard
•
GPS device (optional)
•
Compass (optional)
Stage 3: RF Survey
•
Spectrum Analyzer with Max Hold function and screen capture facility that can store
multiple images, for documentation purposes
•
RF accessories (connectors and cables)
•
Communication devices (for example, cellular phones, or a set of walkie-talkies)
Stage 1: Preliminary Survey
A preliminary survey is necessary before visiting potential installation sites. As much detail as
possible should be obtained about the two designated ODU installation sites and the area
between them.
 To perform a preliminary survey:
1. Mark the two designated installation sites on a topographic map of the area.
2. Measure the distance between the sites; check that it is within the specified range of
the equipment.
3. On the urban map, check for developed areas situated between the two installation
sites. Pay attention to these areas when performing the physical site survey; there
may be tall buildings, RF towers, or transmitters, which could cause interference to
the link.
4. Check the area between the two sites for obstructions such as:
•
High ground - hills or mountains
•
Lakes or large bodies of water. Water has a reflection effect on RF signals like a building. This type of reflection causes the received amplitude to be reduced. As a rule of
thumb, the presence of a large body of water between the link sites may double the
required antenna height.
5. Determine and record the compass bearings between both ODUs, relative to north.
6. If there are obstructions between the two sites, calculate the Fresnel Zone (see
Chapter 21 for details).
7. If the site chosen does not meet requirements, consider alternative sites.
8. Use the Link Budget Calculator (on the CD supplied with the equipment or using the
RADWIN Manager) to determine the expected performance.
RADWIN 2000 User Manual
Release 2.5.40
2-2
Stage 2: Physical Survey
Chapter 2
Stage 2: Physical Survey
The physical site survey reviews the environment of the proposed installation location, to
ensure that the link sites are suitable for the wireless network. The results of the physical site
survey should be recorded.
Note
It is advisable to go on a clear day, so you can more easily see any
obstructions between the two sites.
 To perform a physical survey:
1. From the compass readings taken in the preliminary survey, find the azimuth (horizontal position) that the ODU should face towards the second ODU.
2. Using binoculars, locate any obstructions such as tall trees, high buildings, hills or
mountains. Look for other RF towers between the two sites. Mark the locations of
the obstructions on the map.
3. Determine the location for the ODU (having regard for existing rooftop installations
and tower space). It should be above any obstructions, considering the Fresnel zone
(see Chapter 21).
4. If you need to install the ODU on a tower, make sure that the tower is far away from
overhead electric power lines.
5. Determine a location for the indoor equipment; it should be as close as possible to
the ODU. At an existing site, there is probably an equipment room with cable-routing
channels.
Note
The IDU - ODU cable length limit is 100m, in accordance with IEEE 10/
100BaseT standards.
6. Measure and record the path length of the cable from the ODU position to the indoor
equipment room.
7. Determine the ground and lightning connection points of the installation. The ODU
and IDU must both be grounded.
8. Using the Ohmmeter, measure and record the resistance of the required installation
to the grounding point. The resistance must be less than 1O ohm.
9. Review the results of the physical site survey. Decide if the site is suitable for the
wireless network installation.
•
If the site is suitable, continue with stage 3, the RF survey
•
If the site is not suitable, survey another site
Additional Outdoor Site Requirements
The ambient outdoor operating temperature should be -35 to 60C (-31 to 140F).
Additional Indoor Site Requirements
The following requirements guarantee proper operation of the system:
RADWIN 2000 User Manual
Release 2.5.40
2-3
Stage 3: RF Survey
Chapter 2
•
For IDU-C units, allow at least 90 cm (36 “) of front clearance for operating and maintenance accessibility. Allow at least 10 cm (4 “) clearance at the rear of the unit for
signal lines and interface cables
•
The ambient operating temperature should be 0 to 50°C (32 to 122 °F) at a humidity
of up to 90%, non condensing
Stage 3: RF Survey
The RF survey examines the wireless environment of the installation site, to determine
whether there are available channels within the radio operating frequency band. An RF survey
is performed using a spectrum analyzer.
It is advisable to familiarize yourself with the spectrum analyzer before going out on site, specifically the Max Hold and Marker functions.
You should perform the RF survey at both proposed link sites.
The survey should be carried out during a busy time of day, to best judge the worst-case
radio interference. Allow 2-4 hours duration for a good RF survey.
Note
It is possible to install the link and use the RADWIN Manager to find a clear
channel. Each frequency channel can be evaluated in turn. Achievement of a
clear channel is indicated by the marker in the Quality bar on the Channel
Setting window (see Figure 5-6) moving into the green area.
RF Planning for Dense Installations and Collocated Sites
Interference may arise from
•
Self interference from collocated RADWIN radios
•
Other collocated radio devices installed on the same site.
To avoid or minimize interference, follow these recommendations:
•
For collocated RADWIN units, use an HSS unit to synchronize between them. Select a
different operating channels for each collocated RADWIN unit.
•
If one or more collocated units are not RADWIN units, ensure that there is a physical
separation of at least three meters between a RADWIN unit and any other collocated
radio on the site.
•
Use the largest possible frequency gap between these units.
•
Choose the best frequency channel (as clear as possible form interference). You may
change band with “Combo” WinLink 1000 products and all RADWIN 2000 products).
•
To select a frequency channel, move the link to Installation Mode (using Site configuration) and start the Installation wizard. In the Channel Settings window, use
the quality bar at the bottom to help you choose a better channel (clearer of interference).
•
If you are using WinLink 1000 radios, install the collocated links with different antenna
polarizations.
•
If you are using the RADWIN 2000 radios, use the Spectrum View tool to find the
best working channel (Tools | Spectrum View).
RADWIN 2000 User Manual
Release 2.5.40
2-4
RF Planning for Dense Installations and Collocated Sites
•
Chapter 2
Decreasing the Tx Power of a link will reduce collocation interference (Site Configuration | Air Interface).
Note
Use the Link Budget Calculator to determine the minimum Tx Power
required to maintain link stability.
RADWIN 2000 User Manual
Release 2.5.40
2-5
Chapter 3
Hardware Installation
This chapter sets out the requirements and procedures for the hardware installation and
alignment of a RADWIN 2000 link in accordance with the prior planning as set out in Chapter
2. It is intended to guide qualified field technicians.
Warning
Note
Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may expose the end
user or the service provider to legal and financial liabilities. RADWIN and its
resellers or distributors are not liable for injury, damage or violation of
regulations associated with the installation of outdoor units or antennas.
The material in this chapter is generic to all RADWIN radio link products
unless stated otherwise.
Safety Practices
Preventing overexposure to RF energy
To protect against overexposure to RF energy, install the ODUs so as to provide and maintain
minimal separation distances from all persons.
When the system is operational, avoid standing directly in front of the antenna. Strong RF
fields are present when the transmitter is on. The ODU must not be deployed in a location
where it is possible for people to stand or walk inadvertently in front of the antenna.
Grounding
All RADWIN products should be grounded during operation. In addition:
•
The ODU should be earthed by a wire with diameter of at least 12AWG.
The RADWIN 2000 ODU must be properly grounded to protect against lightning. It is
the user's responsibility to install the equipment in accordance with Section 810 of the
National Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian
Electrical Code. These codes describe correct installation procedures for grounding the
RADWIN 2000 User Manual
Release 2.5.40
3-1
Protection against Lightning
Chapter 3
outdoor unit, mast, lead-in wire and discharge unit. It also lays down the size of
grounding conductors and connection requirements for grounding electrodes.
The RADWIN 2000 ODU must be grounded to a Protective Earth as described in
Chapter 18 and in accordance with the Local Electrical Regulations.
•
The earth lug on the IDU-C should be connected to the protective earth at all times,
by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be
mounted only in earthed racks and cabinets.
Further, you should •
Always make the ground connection first and disconnect it last
•
Never connect telecommunication cables to ungrounded equipment
•
Ensure that all other cables are disconnected before disconnecting the ground
More detailed guidelines are supplied in Chapter 18.
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All of
RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of damage due to lightning strikes. RADWIN recommends the use of additional surge arrestor
devices to protect the equipment from nearby lightning strikes.
See Chapter 18 for detailed installation instructions of lightning protection devices.
General
•
It is recommended that installation of the outdoor unit be contracted to a professional
installer.
•
Before working on equipment connected to power lines or telecommunication lines,
you should remove jewelry or any other metallic object that may come into contact
with energized parts.
•
Use extreme care when installing antennas near power lines.
•
Use extreme care when working at heights.
•
When using an AC power source for RADWIN 2000 always use the AC power adapter
supplied by RADWIN.
•
Use the right tools. In addition to standard tools required for any kind of ODU or
antenna installation, RADWIN 2000 requires additional specific tools detailed on
page 3-5 below.
Package Contents
The RADWIN 2000 packages include the following items:
ODU Package Contents
The ODU package contains:
•
One ODU - see Figure 3-2 and Figure 3-3 below for front and rear view
•
An ODU mounting kit - see Figure 3-1 below
•
A CD containing -
RADWIN 2000 User Manual
Release 2.5.40
3-2
ODU Package Contents
Chapter 3
•
the RADWIN Manager
•
Quick Start Guide
•
User Manual - the document you are reading
•
Link Budget Calculator
•
Label showing the MAC address and the alternative Community string. The label is
self-adhesive. You should keep this label safe
•
Cable glands (to be used with the ODU-IDU cable)
Figure 3-1: ODU Mounting kit
ODU - Front View
ODU - Rear View
Figure 3-2: Connectorized ODU - Front and rear views
RADWIN 2000 User Manual
Release 2.5.40
3-3
IDU-E package containing:
ODU - Front View
Chapter 3
ODU - Rear View
Figure 3-3: Integrated ODU - Front and rear views
IDU-E package containing:
•
IDU-E
•
AC/DC Converter
•
IDU-E wall-mounting drilling template
•
Self adhesive label showing the IDU LED operation
Figure 3-4: IDU-E- front view
IDU-C Package Contents
The IDU-C package contains:
•
IDU-C - see Figure 3-5 below.
•
19” rack mounting kit - see Figure 3-7 below
•
Two DC power plugs for power cables - see Figure 3-7 below
Figure 3-5: IDU-C Package contents - the IDU-C, Ethernet only
RADWIN 2000 User Manual
Release 2.5.40
3-4
External Antenna Package Contents
Chapter 3
Figure 3-6: IDU-C Package contents - the IDU-C, 16 E1/T1 ports
Figure 3-7: IDU-C Package contents - the mounting kit and DC power plugs
External Antenna Package Contents
•
Antenna
•
RF cable 1m (3’) long; two cables supplied with bipolar antennas, single cable supplied with monopolar antennas
•
Mounting kit
Additional Tools and Materials Required
The following is a list of the equipment and materials required to install RADWIN 2000 hardware.
Tools and Materials
•
Crimping tool for RJ-45 (if the ODU-IDU cable is without connectors)
•
Spanner/wrench 13 mm (½”)
•
Drill (for wall mounting only)
•
Cable ties
•
Sealing material
Cables and connectors
•
ODU grounding cable 12AWG
•
IDU grounding cable 18AWG
•
ODU-IDU cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG)
•
For PoE based links: A crossed Ethernet LAN cable
RADWIN 2000 User Manual
Release 2.5.40
3-5
Hardware Installation Sequence
Chapter 3
Hardware Installation Sequence
The following steps are required to install the RADWIN 2000 system:
1. Mounting the ODUs, page page 3-7.
2. Mounting the external antennas (if used), page page 3-7.
3. Mounting the Lightning Protection devices (if used), page page 3-8.
4. Outdoor connections, page page 3-8.
5. Mounting the IDUs, page page 3-9.
6. Indoor connections, page page 3-12.
7. Aligning the ODUs/antennas, page page 3-13.
See Figure 3-8 below, which illustrates a typical installation of a RADWIN 2000 or a WinLink
1000 with external antenna(s).
Figure 3-8: Typical Installation (with external antenna) Left: RADWIN 2000 Right: WinLink
1000
The installation steps are detailed in the following sections.
RADWIN 2000 User Manual
Release 2.5.40
3-6
Outdoor installation
Chapter 3
Outdoor installation
Preparing the ODU before Deployment
Each ODU must be pre-loaded with an IP address. This may be done prior to deployment in
the field, or on-site using a Laptop computer. The process is quite straight-forward and
described in Chapter 19.
Mounting the ODU
The ODU can be mounted on a pole or a wall. In both installations, the supplied mounting kit
is used to secure the ODU.
A mast-sited ODU typically uses a pole attached to the mast.
Note
A RADWIN 2000 link operates in pairs of two ODUs with the same configuration. Both ODUs
must be installed, and the antennas aligned for maximum throughput.
Prior to connecting cables to the ODU, the protective earth terminal (screw)
of the ODU must be connected to an external protective ground conductor
or to a grounded pole.
Warning
•
•
Only a qualified person using the proper safety equipment should
climb the antenna mast
Only qualified professional personnel should install or dismantle
ODUs and masts
 To mount the ODU on a pole or a wall:
1. Ensure that the ODU is properly grounded.
2. Mount the ODU onto the pole or wall. Ensure that the unit is oriented so that the
cable connectors are at the bottom. (If they are on top, water may penetrate
into the unit causing damage.) It is possible to mount an ODU horizontally. See
Chapter 17 for details.
3. Refer also to Chapter 17 for detailed ODU mounting kit contents and schematics.
•
Note
•
Do not tighten the ODU to its mounting brackets until the alignment
process of the antenna is complete.
Ensure that there are no direct obstructions in front of the ODU or
interference from man-made obstacles.
Mounting external antennas
If you are using ODU with an integrated antenna, skip to Mounting the Lightning Protection Devices below.
The supplied mounting kit is used to mount the antenna onto a pole. The antennas must be
aligned for maximum throughput.
RADWIN 2000 User Manual
Release 2.5.40
3-7
Mounting the Lightning Protection Devices
Chapter 3
Do not stand in front of a live antenna.
Warning
 To mount an external antenna:
1. To mount an external antenna, ensure that the antenna is properly grounded and
then mount the antenna onto the pole. Refer to Chapter 17 for detailed antenna
mounting instructions.
2. Follow the mounting instructions supplied with the antenna.
Mounting the Lightning Protection Devices
The use of lightning protection is dependent on regulatory and end user requirements. The
RADWIN 2000 ODU is designed with surge limiting circuits to minimize the risk of damage
due to lightning strikes. RADWIN recommends the use of additional surge arrestor devices to
protect the equipment from nearby lightning strikes.
Refer to Chapter 18 for detailed installation instructions of lightning protection devices.
Outdoor Connections
 To complete the outdoor connections:
1. Connect the ground cable to the ODU chassis as marked on the ODU.
2. Connect the antenna cable(s) to the ODU.
3. Connect the lightning protection device to the ODU (see Chapter 18).
4. Attach the ODU-IDU cable to the ODU RJ-45 connector (see Appendix B for the
connector pinout)
5. Screw in the cable glands to ensure hermetic sealing of the ODU.
6. Secure the cables to the pole, mast or brackets using UV-rated cable ties.
Indoor Installation
Installing IDU-E
IDU-E Installation
The IDU-E can be wall mounted, placed on a desktop or take up one half of a 1U rack slot.
The unit should be grounded, cabled to the ODU and connected to power using the supplied
AC/DC adapter.
Figure 3-9: New style IDU-E: Rear panel
RADWIN 2000 User Manual
Release 2.5.40
3-8
Mounting the IDU-C
Chapter 3
Mounting the IDU-C
IDU-Cs are all rack mountable, as shown in Figure 3-10. A front panel keyed schematic of a
rack mounted IDU-C is shown in the figure below.
Figure 3-10: IDU-C front panel
Further description of the keyed items in Figure 3-10 is shown in Table 3-1 below:
Table 3-1: Components of an IDU-C front panel
Key
Label
Remarks
Indicator LEDs
See Figure 3-11.
ODU Port
RJ-45 connector, see Table B-1.
LAN RJ45Ports
Ethernet, RJ-45 connector, see Table B-3.
LAN SFP Port
See Appendix C.
Alarm Ports
Standard DB25 female connector, see Table B-7.
Label indent
Place for adhesive identification labels.
Primary 3 pin Power Connector
Secondary 3 pin Power Connector
Grounding Lug
Rack mounting holes
Detachable Rack mounting brackets
0, 4, 8 or 16 E1/T1 Ports
See Table B-5.
Standby Port
Hot Standby ready: HSB cable socket, see Table B-6.
Standard 3 pins in line power connector, see Table B-8.
Use the lug supplied.
The Indicator LEDs (Item A in Table 3-1 above) are shown in more detail below:
Figure 3-11: IDU-C Front Panel LEDs
The IDU-E Front Panel LEDS look like this and are functionally the same as the IDU-C LEDs.
RADWIN 2000 User Manual
Release 2.5.40
3-9
Mounting the IDU-C
Chapter 3
Figure 3-12: IDU-E Front Panel LEDs
The purpose of the LEDs is shown in Table 3-2 below:
Table 3-2: IDU-C Front Panel LEDs
Name
IDU
Color
Function
Green
IDU operational
Blinking Green
During power-up only
Red
Failure
Blinking Orange
During power-up; continues if ODU fails to load IDU firmware.
Also, when using an IDU-C to replace a PoE device in which case all other LEDs off.
ODU
AIR I/F
SVC
HSS
Green
ODU-to-IDU communication link is operating
Red
ODU-to-IDU communication link is disrupted
Green
Wireless link is synchronized
Orange
During installation mode; also signals software mismatch on some identical ODUs
Red
Wireless link lost synchronization
Green
E1 or T1 line is synchronized
Orange
Alarm detected at the opposite site interface; Normal or LOSS
Blinking Orange
Local or remote loopback
Red
Alarm detected at this site interface
Off
Ethernet only IDU or E1/T1 not configured
See supplementary Table 3-3 following.
Hot Standby Mode - for use with
Trunks only
Link State
Green
Primary
Active
Blinking Green
Secondary
Not active
Red
Primary
Not active
Orange
Secondary
Active
Off
Off
HSM not activated
Hot Standby Mode - For use with
Ethernet only in a 1+1 Ring
application)
Link State
STBY
Green
Blinking Green
Red
Hardware ready
Orange
Off
RADWIN 2000 User Manual
Release 2.5.40
3-10
Connecting power to the IDU
Chapter 3
Table 3-3: IDU-C and New Style IDU-E Front Panel LEDs for HSS
Color
Function
Green
This ODU is HSS master, generating signal, and HSS Sync is OK
Blinking
Green
This ODU is a HSS client and in Sync
Red
HSS not operational due to improper signal detection. This ODU is not transmitting
HSS is operational. One of the following conditions apply:
Orange
•
This ODU is a master that is generating signals and detecting signals
•
This ODU is a master that is generating signals but detected improper signals
•
This ODU is a client “Continue Tx” but is not detecting signals
•
This ODU is a client “Disable Tx” and is detecting signals from multiple sources
All orange cases transmit.
Off
HSS is not activated
Disconnection between ODU and IDU
 To mount an IDU-C:
1. Attach the rack mounting brackets (K) to the IDU.
2. Bolt the IDU into an empty slot in the rack, ensuring that it sits securely.
3. Ground the IDU to the rack using grounding lug I. The IDU should be left permanently grounded.
Note
Instead of using the rack mounting brackets, the IDU may be rail mounted
using the four screw holes on each of its sides.
Connecting power to the IDU
The IDU-C has redundant power connection circuits (items G and H in Figure 3-10 above).
An enlarged schematic of the power connectors is shown in below:
Figure 3-13: IDU-C Power connectors
The connectors are 3 pin in line female, with polarities (left to right) minus, ground, plus. To
avoid damage to the IDU, always use an AC/DC adapter supplied by RADWIN.
Ensure that the IDUs at both sites are powered up.
The IDU-E has a single three pin power connector, the same as used on the IDU-C.
RADWIN 2000 User Manual
Release 2.5.40
3-11
Connecting the ODU to the IDU
Chapter 3
Connecting the ODU to the IDU
The ODU-IDU cable conducts all the user traffic between the IDU and the ODU, and also provides power to the ODU. The maximum length of the ODU-IDU cable is 100m (328ft) in
accordance with 10/100BaseT standards.
The ODU-IDU cable is supplied pre-assembled with RJ-45 connectors, at the length specified
when ordering, or as a cable drum with spare connectors. If the ODU-IDU cable was not
ordered, use an outdoor class, CAT-5e 24AWG shielded cable. See Appendix B for Wiring
Specifications.
To connect the ODU to the IDU, route the cable from the ODU to the IDU, secure the cable
along its path and connect the cable to the ODU RJ-45 connector on the IDU (see item B in
Figure 3-10 above).
Installing a Link using PoE Devices
The PoE device is a very simple unit having a power input connector and two Ethernet ports.
It is AC powered, and has a power LED.
 To prepare a link using PoE devices:
1. To connect the ODU to the PoE device, route the cable from the ODU to the PoE
device, secure the cable along its path and connect the cable to the LAN-OUT RJ-45
connector on the PoE device.
2. Connect it to AC power.
3. Repeat steps 1 to 2 for the second link.
Connecting User Equipment
 To connect user equipment to an IDU:
1. Connect user switch/router or any other compatible device to the IDU panel RJ-45
ports designated LAN. (For an IDU-C, see item C in Figure 3-10 above.)
2. Connect user E1/T1 traffic to the IDU panel RJ-45 ports designated TRUNKS. (For an
IDU-C, see labeled item L in Figure 3-10 above.)
3. IDU-C only: To use the SFP Port (labeled item D in Figure 3-10 above), insert an
SFP plug-in module into the port and connect the user switch/router or any other
compatible device to the SFP plug-in module.
Refer to Appendix B for connector pinouts.
Do not connect two LAN ports to the same network, or flooding may occur.
Note
 To connect user equipment to a PoE device:
• Connect a user switch, router or any other compatible device to the PoE device RJ-45
port designated LAN-IN. Refer to Appendix B for connector pinouts.
RADWIN 2000 User Manual
Release 2.5.40
3-12
Connecting and Aligning ODUs / Antennas
Chapter 3
Connecting and Aligning ODUs / Antennas
You perform antenna alignment using the ODU's audible tone.
To speed up the installation time, alignment of a RADWIN 2000 system should be performed
by two teams simultaneously, at site A and at site B.
 To align ODUs with integrated antennas or external bipolar antennas:
1. For external bipolar antennas: Using a coax cable with N-Type connectors, connect
the vertical polarization connector of the antenna to the ANT 1 connector of the
ODU.
2. For external bipolar antennas: Using a coax cable with N-Type connectors, connect
the horizontal polarization connector of the antenna to the ANT 2 connector of the
ODU.
3. Ensure that power is connected to the IDUs at both sites.
4. Ensure normal operation of the IDUs by the LED indications on the front panel.
Provided that site A detects the signal from site B, the ODU starts beeping 20 seconds after power up, and continues beeping until the ODUs are aligned, and the
installation is complete.
In the following steps, “antenna” refers both to an external antenna and an integrated antenna.
5. Direct the antenna of site B in the direction of site A. This is simplified if a previous
site survey has been completed and azimuths are known.
When aligning the antennas, do not stand in front of a live antenna.
Warning
6. Make a horizontal sweep of 180 degrees with the site A antenna so that the strongest
signal from site B can be detected.
7. Slowly turn the site A antenna back towards the position of site B, listening to the
tone until the best signal is reached. See the following figure for audible signal variations.
RADWIN 2000 User Manual
Release 2.5.40
3-13
Connecting and Aligning ODUs / Antennas
Chapter 3
Figure 3-14: Beep Sequence for antenna alignment
Note
•
•
•
•
•
•
Three beeps and a pause is 'best signal so far'
Two beeps and a pause is 'signal quality increased'
One beep and pause is 'no change in signal'
Long beep and short pause is 'signal quality decreased'
One beep and a long pause is 'no air link'
Any other signal does not relate to antenna alignment
8. Secure the site A antenna to the pole/wall.
9. Repeat steps 4 to 8 for site B.
 To align two external monopolar antennas:
The ODU buzzer only works on the radio connected to the ANT 1 connector
marked
Note
. You will therefore need to use ANT 1 to align both antennas in
turn. Upon completion of the alignment procedure, you may connect the
two antennas to ANT 1 and ANT 2 connectors.
1. Using a coax cable with N-Type connectors, connect one antenna to the ANT 1 connector of the ODU.
2. Follow the steps 3 to 7 above to align the antenna connected to the ODU connector
ANT 1 on both sides of the link.
3. On both sides of the link, disconnect the antenna connected to the ODU connector
ANT 1. Connect the other antenna to connector ANT 1 and follow the steps 3 to 7
above to align the second antenna.
4. Secure the antennas to the pole/wall.
5. Restore one of the antennas to ANT 2 on both sides of the link.
RADWIN 2000 User Manual
Release 2.5.40
3-14
Chapter 4
Getting Started with the
RADWIN Manager
Installing the RADWIN Manager Application
Minimum System Requirements
The RADWIN Manager application is distributed on a CD. Operating system specific PC
resources required by the application are set out in Table 4-1 below:
Table 4-1: PC Requirements for the RADWIN Manager Application
Windows Version
2000
XP Pro
Vista/7
Memory
128 MB
512 MB
1 GB
Processor
P III
P IV
P IV Dual Core
Requirements common to all systems are:
•
Hard disk: 1 GB free space
•
Network: 10/100BaseT NIC
•
Graphics: 1024x768 screen resolution with 16 bit color
•
Microsoft Explorer version 5.01 or later
Installing the Software
Any PC running the RADWIN Manager application can be used to configure a RADWIN 2000
link.
 To install the RADWIN Manager application:
1. Insert the CD into the CD/DVD drive of your computer.
The CD opening window appears:
RADWIN 2000 User Manual
Release 2.5.40
4-1
Getting Started with the RADWIN Manager
Chapter 4
2. Choose Install RADWIN Manager and follow the on-screen instructions of the installation wizard to complete the setup of the RADWIN Manager application.
If the installation program fails to start, browse to your CD/DVD drive, chose the
setup.exe program and run it.
Getting Started with the RADWIN Manager
If your links are within easy reach, you can configure them using the procedure described
below. If however, your links are to be geographically scattered, it may be convenient to preload each ODU with its network address prior to physical installation. The procedure is quite
straight forward, and set out in Chapter 19.
Note
Each ODU requires a static IP address, since part of the link definition is the
IP address pair of both ODUs. Network Managers should ensure that these
addresses are outside of the automatic allocation ranges used by their
network DHCP server.
 To start the RADWIN Manager:
1. Connect the managing computer to one of the two LAN ports as shown in Figure 41 below:
RADWIN 2000 User Manual
Release 2.5.40
4-2
Getting Started with the RADWIN Manager
Chapter 4
Figure 4-1: LAN ports on the front panel of the IDU-C
For IDU-E users: The LAN ports are located on the rear panel on the unit.
Note
If you are not using a direct connection as above, ensure that you have IDU to managing computer connectivity (e.g. through a LAN).
2. Check that you have connectivity to the ODU. You can do this by opening up a command line session (Start|Run and then type, cmd). At the command prompt, type
ping 10.0.0.120
You should see something like this:
Figure 4-2: Pinging an uninstalled and unconfigured link
Any other response from ping means that the ODU is not responding. Check your
Ethernet connection and that both the IDU and ODU are switched on and then try
again. If you do not succeed, seek assistance from RADWIN Customer Support.
3. Dismiss the command line session.
4. Double-click the RADWIN Manager icon on the desktop, or click Start|Programs|RADWIN Manager|RADWIN Manager.
The Log-on dialog box appears.
RADWIN 2000 User Manual
Release 2.5.40
4-3
The RADWIN Manager log-on Concept
Chapter 4
Figure 4-3: First time log-on window
The RADWIN Manager log-on Concept
The RADWIN Manager provides three levels of access in one of two entry modes. To see
them, click Options at any time in the Log on window (Figure 4-3 above). You are offered
an extended log-on window:
Figure 4-4: Extended log-on window
Note
Connection through the RMNS Sever will be available in a future release. If
you have an immediate requirement for this service, please contact
RADWIN Customer Support.
At the User Type field, click the list button:
RADWIN 2000 User Manual
Release 2.5.40
4-4
The RADWIN Manager log-on Concept
Chapter 4
Figure 4-5: Log on window exposing the user types.
There are three user types:
•
An Observer has read-only access to the link. An Observer can monitor the link, generate reports, but may not change any link parameters.
•
An Operator can install and configure the link.
•
An Installer can, in addition to functioning as an Operator, also change the operating
band. The latter function has legal ramifications, requiring familiarity with local regulations.
The following table summarizes these options:
Table 4-2: User types, default passwords and function
User Type
Default
Password
Function
Community
Community
String
Observer
admin
Monitoring
Read-Only
public
Operator
admin
Installation,
configuration
Read-Write
netman
Installer
wireless
Operator plus
set band
Read-Write
netman
The Network Manager should change the default passwords as soon as possible.
 Continuing the log-on procedure:
5. Type an IP address for the ODU (if you connect through a LAN), or click Local Connection (if you are connected directly to the IDU port).
RADWIN 2000 User Manual
Release 2.5.40
4-5
Log-on Errors and Cautions
Chapter 4
•
If you log on using Local Connection, but your physical connection
is not local (i.e. anything other than a direct connection between the
managing computer and the IDU), then any configuration you carry
out may affect other links in the network. Do not do this!
•
•
Network log on (IP address to the ODU) is recommended.
If you log on via an over-the-air IP address, you will receive a warning. If you reset the site to which you are connected to factory settings, you can lock yourself out of the link.
•
If you log on using Local Connection through a PoE device, you will
need to connect it to the managing computer using a crossed Ethernet cable.
The default IP address for the ODU is 10.0.0.120. The subnet mask is
255.0.0.0.
The actual IP address is defined during link configuration (see Site
Management: IP Address, VLAN and Protocol on page 8-7. See
also, Chapter 19).
Warning
•
Note
•
6. If your User Type is not Operator, then choose it now.
7. Enter the password.
8. If you are a user with Read-Write permission, click Options to enter the Community
options if required
9. For initial log on:
•
Leave the default Community passwords, netman for read-write, and public for
read-only.
•
If Community values were previously defined, enter them under Community in the
Read-Only or Read-Write boxes.
•
If you are a user with read-only permission, then you may only log on as Observer.
The RADWIN Manager main window is displayed (see Figure 4-10).
Log-on Errors and Cautions
Unsupported Device
Attempting to connect to an unsupported device on an otherwise valid IP address (for example, a LAN printer) will result in the following error message:
RADWIN 2000 User Manual
Release 2.5.40
4-6
Incorrect IP Address
Chapter 4
Figure 4-6: Unsupported device message
Incorrect IP Address
If the IP address chosen is invalid or the link is unreachable, the following error message will
be displayed:
Figure 4-7: Unreachable device message
In both of the above situations, if you click No, you will see a warning graphic
the IP Address field.
alongside
Incorrect Password
If you type an incorrect password in the Login window, you will see a warning graphic
alongside the password field.
Invalid Read/Write Community String
This will result in the following message:
Figure 4-8: Invalid Community String message
Logging in to the Over-the-Air Site
You can log on to the over-the-air site of an established link (Site B in our example). However,
you will be first offered the following caution:
RADWIN 2000 User Manual
Release 2.5.40
4-7
Continuing without an IP Address
Chapter 4
Figure 4-9: Logging on to an over-the-air site
Continuing without an IP Address
The RADWIN Manager provides limited “offline” functionality when there is no accessible
IDU/ODU. It is primarily for setting managing computer related parameters, running the Link
Budget Calculator or viewing online Help. The offline functionality is shown in Table 4-3
below. The table does not show menu items grayed out.
Table 4-3: RADWIN Manager: Offline Functionality
Menu level
Top
+1
Function
+2
Log Off
Return to log-on dialog. Same as Log Off
button
Exit
Exit the RADWIN Manager. Same as Exit
button
Change
Password
Change the log-on password
File
Tools
Help
Events Log
Clear Events
Clear local events log
Save to File
Save events log data to a file
Reference
page 4-8
page 9-17
Preferences
Set managing computer preferences
RADWIN
Manager Help
View online help version of the User Manual
Link Budget
Calculator
Calculator opened in default browser
Chapter 21
Get Diagnostics
Information
Obtain system information
page 9-1
About RADWIN
Manager
RADWIN Manager build information
Changing the Log-On Password
 To change the log on password:
1. From the Tools menu, select Change Password.
The Change Password dialog box appears.
RADWIN 2000 User Manual
Release 2.5.40
4-8
First steps
Chapter 4
2. Enter the current password, and the new password.
Note
A valid log-on password must contain at least five characters excluding
SPACE, TAB, and any of “>#@|*?;.”
3. Click OK to confirm.
First steps
For what follows, it is assumed that you have set the IP addresses of both
ODUs. For the purposes of illustration, we will use the following IP
addresses:
Note
Our managing computer has its NIC set to IP address 192.168.1.100. The
log-on ODU is set to IP address 192.168.1.101 and the over-the-air ODU is
set to 192.168.1.102. The Subnet Mask for both sites is 255.255.255.0 and
the Default Gateway is left unset. We will maintain this arrangement
throughout the remainder of this manual.
Other defaults are shown in Table 4-4.
At this point the main window of the RADWIN Manager should be displayed:
Figure 4-10: Opening RADWIN Manager window prior to installation - IDU-C
RADWIN 2000 User Manual
Release 2.5.40
4-9
First steps
Chapter 4
The Dynamic Tx Ratio bar only appears for model RADWIN 2000 C
Note
A detailed field by field description of the contents of the RADWIN Manager main window
may be found in Chapter 6.
The procedure required to make the link functional has three phases:
1. Link Installation - which we will detail below.
Installation actually gets the link operational by setting the link parameters. It uses a fixed
channel at the lowest possible modulation, BPSK at 6.5Mbps and will work under the harsh
interference condition.
Note
During the installation procedure, the definition of all parameters is
automatically applied to both sides of the link.
•
Caution
•
The ODUs as supplied by RADWIN are set up with a factory default
band. If for some reason the default band needs to be changed, it
should be done before link Installation. The procedure is set out in
Chapter 20.
Use of an incorrect band may be in violation of local regulations.
2. Link Configuration - described in Chapter 7.
Configuration provides much the same functionality as Installation, but for a running link.
A fallback to Installation mode is provided for situations which cannot be handled without
resetting the link, such as antenna realignment and IDU or ODU replacement.
The Link Installation and Configuration phases are both carried out with Wizards, which
“walk you through” the processes. The Wizards are visually quite similar and will be
described in detail below.
3. Site Configuration - described in Chapter 8.
Site specific configuration for each side of the link is available at any time - under a running link or under the restricted Installation mode.
Site Configuration consists of a set of panels, which may be invoked individually in any
order, as needed.
An installed and configured link can be returned to installation mode for reinstallation and configuration from last settings or from factory settings.
•
Note
•
Reversion to installation mode requires a complete break in the link
service
Configuration mode may vary the service throughput and quality, but
without a service break
RADWIN 2000 User Manual
Release 2.5.40
4-10
Default RADWIN 2000 Settings
Chapter 4
Default RADWIN 2000 Settings
The default settings of the RADWIN 2000 configuration parameters are listed in the second
column of Table 4-4 below. The third column shows the values we use in this manual for
illustrative purposes.
Table 4-4: Default Settings
Parameter
Default Value
Illustrative Value
Factory default band
Product dependent
5.820GHz
ODU IP Address
10.0.0.120
192.168.1.101 and 102
Subnet Mask
255.0.0.0
255.255.255.0
Trap destination
0.0.0.0
0.0.0.0
RADWIN Manager log-on
passwords
Observer
admin
Operator
admin
Installer
wireless
Link ID
Link
EBG_20561334
Link Name
Name
TPSF_BTT
Site 1
Site
Site 2
Site
Location (per site)
Location
Name (per site)
Name
Here
There
Contact (per site)
Person
John
Mary
Link Password
Rate
Ethernet Configuration
Radio Link Failure Actions
Bridge or Hub mode
Community values
wireless-bridge
Adaptive
Auto Detect
No action
Hub Mode, Aging time = 300 sec
Read-write – netman
Read-only – public
Using RADWIN Manager Spectrum View
Prior to running the Installation Wizard (Chapter 5), you may use the RADWIN Manager
Spectrum View utility.
The RADWIN Manager Spectrum View utility is an RF survey tool designed to support the link
installation prior to full link service activation. The tool provides comprehensive and clear
information enabling easier, faster and better quality installations.
To launch Spectrum View, go to the main window menu (Figure 4-11) and click Tools |
Spectrum View. A display similar to the following appears:
RADWIN 2000 User Manual
Release 2.5.40
4-11
Using RADWIN Manager Spectrum View
Chapter 4
Figure 4-11: Spectrum View - Opening Display on installed link
See Chapter 23 for detailed information about operating Spectrum View and understanding
the displayed statistics.
RADWIN 2000 User Manual
Release 2.5.40
4-12
Chapter 5
Installing the Link
Overview
The installation is carried out using the Installation wizard. Its operation is detailed in the following pages in a tutorial style.
For the purpose of explanation, we will set up a laboratory link with the following characteristics:
•
Channel selection: Automatic
•
Antennas: Dual at both sites
•
Services: Ethernet + 7xE1 on ports 1, 2, 3, 8, 10, 11, 14. It is unlikely that you would
use a non-contiguous set of ports - but this shows that if required, it can be done.
The Installation wizard has steps as shown in Table 5-1 below.
RADWIN 2000 User Manual
Release 2.5.40
5-1
Overview
Chapter 5
Table 5-1: Link Installation Wizard
Wizard welcome
System parameters
•
Link ID
•
Site details
Channel settings - ACS
Configuration
Tx Power and antenna
settings, MIMO or
Diversity
HSS Settings
Services - Types
RADWIN 2000 User Manual
Release 2.5.40
•
Ethernet
•
TDM
Adaptive or fixed, Jitter
Buffer, MHS, Ethernet
Ring, QoS
Set TDM Clock
Parameters
Wizard summary and
completion
5-2
Installation
Chapter 5
Installation
Step 1, Start the Wizard
In the tool bar of the RADWIN Manager main window, click the Link Installation button.
The Link Installation button is only accessible if the antennas are properly aligned. If this box
is “grayed out”, you should align the antennas as set out in Chapter 3 on page 3-16.
The Installation Wizard opens:
Figure 5-1: Link Installation Wizard
The bottom data area reproduces the corresponding data from the main window - which the
above panel obscures. See Chapter 6 for a field by field description of this data area.
Click Next to proceed with the installation procedure.
Step 2, System Parameters
The system dialog box opens:
RADWIN 2000 User Manual
Release 2.5.40
5-3
Installation
Chapter 5
Figure 5-2: Installation Wizard, System dialog box
 To complete Installation Step 2:
1. Enter a Link ID. The Link ID must be identical for both ODUs in the link, otherwise they will not communicate. The Link ID must include at least eight
alphanumeric characters. Up to 24 characters are allowed. You should use a Link ID
composed of both alphabetic and numeric characters.
2. Enter a Link Name for the link identification. The default name is “Link”. You should
change it.
3. Enter names for Site 1 and Site 2. The default names are both “Location”. You should
change them. Throughout this manual, we use A for Site 1 and B for Site 2.
4. Optionally enter a new Link Password.
If the Link Password is incorrect a link is established but configuration
cannot be performed and no services are available. A new link password
may be obtained from RADWIN Customer Support or use the alternative
password supplied with the product.
Note
The link password is peculiar to the link itself and should not be confused
with the RADWIN Manager log on password.
Here is our completed System panel:
RADWIN 2000 User Manual
Release 2.5.40
5-4
Installation
Chapter 5
Figure 5-3: Installation Wizard, System dialog box filled out
5. Click Next.
The default link with a rate of 6.5 Mbps is evaluated.
The Channel Setting dialog box appears. Proceed to Channel Settings, below.
Changing the Link Password
The default password is wireless-bridge. Optionally, you can change the link password as
explained here.
 To change the link password:
1. Click the Change button in the System dialog box.
The Change Link Password dialog box opens.
Use the Hide characters check box for maximum security
Note
RADWIN 2000 User Manual
Release 2.5.40
5-5
Installation
Chapter 5
Figure 5-4: Change Link Password dialog box
2. Enter the current link password (The default link password for a new ODU is wireless-bridge).
If you have forgotten the Link Password, click the Forgotten Link Password button.
The following window is displayed:
Figure 5-5: Lost or forgotten Link Password recovery
Follow the instructions to use the Alternative Link Password, and click OK to finish.
You are returned to the window in Figure 5-4 above. Continue with the next step.
3. Enter a new password.
4. Retype the new password in the Confirm field.
5. Click OK.
6. Click Yes when asked if you want to change the link password.
7. Click OK at the Password changed success message.
•
•
Note
•
A link password must contain at least eight but no more than 16
characters excluding SPACE, TAB, and any of “>#@|*?;.”
Restoring Factory Defaults returns the Link Password to wirelessbridge.
If the link is inactive, then the link password may also be changed
from the Site Configuration dialogs. See page 8-13.
RADWIN 2000 User Manual
Release 2.5.40
5-6
Installation
Chapter 5
Step 3, Channel Settings
RADWIN 2000 systems have a feature called Automatic Channel Selection (ACS). In the event
of sync loss, ACS chooses the first available channel in a list of monitored channels nominated
in the Channel settings window of Figure 5-6 below. A channel switch takes place sufficiently fast as to ensure no loss of service.
Figure 5-6: Channel Settings - Automatic Channel Selection
The default frequency for the product is shown.
 To select channels to be used by the link:
1. Select the installation frequency from the Installation Channel box.
RADWIN 2000 User Manual
Release 2.5.40
5-7
Installation
Chapter 5
Figure 5-7: Channel Settings - Showing available installation rates
2. Choose the required Channel Bandwidth.
Figure 5-8: Channel Settings - Showing available Channel Bandwidths
3. Click the check box if Automatic Channel Selection is required.
4. The Available Channels List contains all of the allowable channels for the link. Check
the channels that can be automatically selected.
RADWIN 2000 User Manual
Release 2.5.40
5-8
Installation
Chapter 5
Selecting a new channel causes the system quality to change. The Quality bar provides an indication of the link quality from No serv(ice) (red) to Ethernet + TDM
(green) as shown in the bottom of Figure 5-7 above.
5. Click Next.
Step 4, Tx Power and Antenna Settings
The Tx Power and Antenna Parameters dialog appears.
Figure 5-9: Transmission Power and Antenna Parameters
The choice of Tx Power, antenna gain and cable loss (between the radio and the antenna)
determines the EIRP and is affected by such considerations as radio limitations and regulatory
restrictions.
Before proceeding to antenna installation details, the following background information
should be considered:
About Single and Dual Antennas
Each RADWIN 2000 ODU is made of two radio transceivers (radios). The radios make use of
algorithms that utilize both MIMO and Diversity resulting in enhanced capacity, range and link
availability. The number of antennas (i.e. radios) used is determined by user configuration
and by automatic system decisions, explained below.
Dual Antennas at Both Sites
When using dual antennas at both sites (single bipolar antenna or two mo-unipolar antennas)
you can choose between MIMO Mode and Diversity Mode.
RADWIN 2000 User Manual
Release 2.5.40
5-9
Installation
Chapter 5
MIMO Mode
With MIMO the system doubles the link capacity. At the same time, it keeps the same rate
and modulation per radio as was used with single antenna, thus increasing capacity, range
and availability.
For example with a dual antenna RADWIN 2000 can transmit at modulation of 64QAM and
FEC of 5/6 and get an air rate of 130 Mbps, compared to 65 Mbps with single antenna.
To work in this mode, each antenna port must be connected to an antenna, the RSS level in
both receivers should be balanced and a minimal separation between the antennas must be
maintained. (For example, by using dual polarization antennas a cross polarization separation
is attained).
Upon selecting Antenna Type as Dual, RADWIN 2000 automatically selects MIMO mode and
doubles the air rates.
RADWIN Manager indicates a case of unbalanced RSS between the two antennas.
Diversity Mode
Diversity Mode uses two antennas to improve the quality and reliability of the link. Often,
there is not a clear line-of-sight (LOS) between transmitter and receiver. Instead the signal is
reflected along multiple paths before if-ally being received.
Each such “bounce” can introduce phase shifts, time delays, attenuations, and even distortions that can destructively interfere with one another at the aperture of the receiving
antenna. Antenna diversity is especially effective at mitigating these multi-path situations.
This is because multiple antennas afford a receiver several recordings of the same signal.
Each antenna will be exposed to a different interference envy-remnant. Thus, if one antenna
is undergoing a deep fade, it is likely that another has a sufficient signal. Collectively such a
system can provide a or-bust link.
Antenna diversity requires antenna separation which is possible by using a dual-polarization
antenna or by two spatially separated antennas.
Use Diversity instead of MIMO in the following situations:
•
When the system cannot operate in MIMO Mode
•
When one of the receivers has high interference compared to the second receiver (i.e.
the system is “unbalanced”)
•
When you achieve higher capacity in Diversity Mode than in MIMO Mode
•
When high robustness is of importance and the capacity of Diversity Mode is sufficient
(up to 25 Mbps full duplex)
Single Antennas at Both Sites
By selecting a single antenna at both sites the ODUs operate with a single radio that is connected to the ANT 1 connector. The second radio is automatically shut down.
Single at One Site, Dual Antennas at the Other
In this mode one of the sites uses the ODU with a single antenna while the other site uses the
ODU with a dual antenna.
The advantages in this mode in comparison to using a single antenna in both sites are doubled total Tx Power and additional polarization and/or space diversity (depending on the
polarization of installed antennas).
RADWIN 2000 User Manual
Release 2.5.40
5-10
Installation
Chapter 5
The air rates used in this mode are same as when using single antennas in both sites.
Table 5-2 summarizes the situation:
Table 5-2: MIMO - Diversity settings
Number of
Antennas
Site A
Mode
Graphic Indication
Site B
Max Full
Duplex
Capacity
MIMO
50 Mbps
Diversity
25 Mbps
25 Mbps
25 Mbps
25 Mbps
The rates used by RADWIN 2000 are shown in Table 5-3 below:
Table 5-3: RADWIN 2000 Air rates
Antenna
Modulation
FEC
Air-Rate
[Mbps]
Single
BPSK
1/2
6.5
Single
QPSK
1/2
13
Single
QPSK
3/4
19.5
Single
16QAM
1/2
26
Single
16QAM
3/4
39
Single
64QAM
2/3
52
Single
64QAM
3/4
58.5
Single
64QAM
5/6
65
Dual
BPSK
1/2
13
Dual
QPSK
1/2
26
Dual
QPSK
3/4
39
Dual
16QAM
1/2
52
Dual
16QAM
3/4
78
Dual
64QAM
2/3
104
RADWIN 2000 User Manual
Release 2.5.40
5-11
Installation
Chapter 5
Table 5-3: RADWIN 2000 Air rates (Continued)
Antenna
Modulation
FEC
Air-Rate
[Mbps]
Dual
64QAM
3/4
117
Dual
64QAM
5/6
130
Considerations for Changing Antenna Parameters
Let:
max Available Tx Power denote the maximum Tx Power practically available from an
ODU. It appears as Tx Power per Radio in Figure 5-10
below.
maxRegEIRP denote the maximum EIRP available by regulation. It will be determined by
three factors:
•
per band/regulation
•
per channel bandwidth
•
antenna gain
It appears in Figure 5-10 as Max EIRP.
maxRegTxPower denote the maximum regulatory Tx Power for the equipment, also
having regard the above three points.
Then, the following relationship must be satisfied:
maxAvailableTxPower  min(maxRegEIRP
– AntennaGain + CableLoss maxRegTxPower)
... (*)
These parameters are controlled as follows:
 To set Tx Power and configure antennas:
1. Click the Configure buttons in turn to configure the antennas on both sides of the
link. Each one offers a dialog like this:
RADWIN 2000 User Manual
Release 2.5.40
5-12
Installation
Chapter 5
Figure 5-10: Antenna configuration dialog
2. Choose the antenna type and required transmission (Tx) power for the first site and
click OK. You will receive the following warning:
Figure 5-11: Antenna type change warning
3. Repeat the process for the second site.
4. At the same time you can set the Antenna Gain and Cable Loss.
The Tx Power (per radio) indicates the power of each radio inside the ODU and is
used for Link Budget Calculations. The Tx Power (System) shows the total transmission power of the ODU and is used to calculate the EIRP according to regulations.
To see the relationship between Tx Power (radio) and Tx Power (system),
note that dBm = 10  log 10milliWatt so that if you double the power in
Note
milliWatts (for two radios) then dBm will increase by 10  log 102  3 .
If you choose to set the Antenna Gain and Cable Loss, you will receive the following
warning message:
RADWIN 2000 User Manual
Release 2.5.40
5-13
Installation
Chapter 5
Figure 5-12: Antenna parameters change warning
•
Note
•
The Max EIRP level will be automatically set according to the selected
band and regulation.
The EIRP level is the sum of the System Tx Power and the Antenna
Gain minus the Cable Loss.
If inequality (*) above is violated, then the following warning window is displayed:
Figure 5-13: Tx Power Limits
The precise relationship between the items in inequality (*) and the window of
Figure 5-10 is as follows:
•
Required Tx Power (per radio) will be adjusted down to the lesser of the value
entered and maxAvailableTxPower
•
Tx Power (system) is maxAvailableTxPower + 3 (for 2 radios)
•
Max EIRP is maxRegEIRP.
•
EIRP is maxAvailableTx Power + Antenna Gain - Cable Loss
The table in Figure 5-13 only shows rates where the maximum Tx Power is the limitation, rather than regulations. When you close the window of Figure 5-13, the
change you requested will not be honored, and you will need to try again.
RADWIN 2000 User Manual
Release 2.5.40
5-14
Installation
Note
Chapter 5
Since our demonstration link is entirely indoors, we have reduced Tx Power
to 5 dBm to obtain a realistic RSS. Although this is much too low for field
use, the method is general.
Figure 5-14: Antennas configured for two dual and Tx power 5 dBm
5. Choose Dual Antenna mode if appropriate. The green Antenna Configuration diagram
indicates the active state. For dual antennas in Diversity mode it looks like this:
There are intermediate modes available for dual antennas opposite a single antenna
as set out on page 5-9 above.
If you make a change you will see a warning similar to this:
A similarly worded warning applies to a s switch from MIMO to Diversity mode
6. When you are finished with Tx Power configuration, Click Next.
RADWIN 2000 User Manual
Release 2.5.40
5-15
Installation
Chapter 5
Step 5, Hub Site Synchronization Settings
Figure 5-15: HSS Settings
The Synchronization Status dialog box displays the current status of each side of the link. See
Chapter 10 for instructions about installing and configuring collocated links. If you do not
require HSS, click Next.
Step 6, Services
The Services dialog appears:
RADWIN 2000 User Manual
Release 2.5.40
5-16
Installation
Chapter 5
Figure 5-16: Services and Rates - RADWIN 2000 C only
Figure 5-17: Services and Rates for RADWIN 2000 collocated as a client
RADWIN 2000 User Manual
Release 2.5.40
5-17
Installation
Chapter 5
Figure 5-18: Services and Rates for models RADWIN 2000 L and RADWIN 2000 PDH
For •
a collocated link
•
Models RADWIN 2000 L and RADWIN 2000 PDH
proceed to TDM Services selection.
Otherwise, you can use the green slider to allocate asymmetric Ethernet capacity by changing
the Transmission Ratio between the sites.
For example: Suppose that during congestion, you might want to use 70% for the downlink
and 30% for the uplink. Your choice would typically be based on your experienced traffic load
during periods of congestion.
If you change the Transmission Ratio, you will be offered the following warning:
Otherwise, click Yes to continue.
RADWIN 2000 User Manual
Release 2.5.40
5-18
Installation
Caution
Chapter 5
If you have active collocated links, or if you are uncertain of whether
collocated links provide TDM services do not use this option now. You can
do it at a less disruptive time using the Link Configuration (Chapter 7).
Limitations on the use of Asymmetric Allocation
For non collocated links, capacity allocation between uplink and downlink traffic is determined
automatically according to actual Ethernet traffic and air interface conditions. Your manual
allocation using this feature “cuts in” during congestion.
Asymmetric Allocation and Collocation
The use of Asymmetric Allocation is limited where the link is collocated. Possible scenarios are
shown in Table 5-4. In all cases where Asymmetric Allocation is available, it is static for all
traffic conditions.
Table 5-4: Asymmetric Allocation with Collocated Links - Scenarios
HSS Master
HSS Client
Scenario: If you try to... Result
Link down
WinLink 1000
RADWIN 2000
RADWIN 2000
•
Releases prior to 2.4 Link down
•
Release 2.4 later (RADWIN 2000 PDH and
RADWIN 2000 L series)
- Link down
Change master to
asymmetric allocation
•
Release 2.4 and later
(RADWIN 2000 C
series) - TDM services
stopped, link set to
transmission ratio of
master
Remarks
Reversion to 50/50 restores link
Release 2.4 and later (RADWIN
2000 C series) - Asymmetric
Allocation slider visible but
cannot be changed
WinLink 1000
RADWIN 2000
RADWIN 2000
Change client to
asymmetric
Asymmetric Allocation slider
not displayed
You cannot do this
Change client to
asymmetric
Asymmetric Allocation slider
not displayed
You cannot do this
WinLink 1000
WinLink 1000
RADWIN 2000
The Services and Rates dialog as shown in Figure 5-16 will be different:
RADWIN 2000 User Manual
Release 2.5.40
5-19
Installation
Chapter 5
Figure 5-19: Services and Rates - RADWIN 2000 C master, RADWIN 2000 clients
The yellow areas should not be used. Using those areas, you may loose the collocated link
with the longest distance between sites.
Asymmetric Allocation and TDM
You cannot use this feature when TDM services are used. Selection of TDM ports as in the
next section will reset the Ethernet balance to 50% in each direction and the green slider will
not appear in subsequent Installation or Configuration runs.
Cancelling TDM port use will make the allocation bar reappear, re-enabling asymmetric Ethernet traffic allocation.
If you are not using TDM services, clicking Next will take you to Step 8, and completion of
the installation. Your Ethernet capacity allocation will be reflected in Figure 5-34 below.
TDM Services selection
 To select services:
1. Click the Configure button. The TDM services dialog is displayed:
RADWIN 2000 User Manual
Release 2.5.40
5-20
Installation
Chapter 5
Figure 5-20: TDM Type selection
2. Using the TDM Type radio buttons, choose E1 or T1. You are now able to select the
required service ports:
Figure 5-21: TDM service port selection
3. Use the spin button to choose consecutive service ports, the Select Maximum button to choose all available ports or click on individual ports to choose them.
•
•
Note
Ethernet is always selected.
The maximum available services will be reduced in accordance with
actual air interface capacity.
RADWIN 2000 User Manual
Release 2.5.40
5-21
Installation
Chapter 5
Figure 5-22: TDM Service port selection - seven services selected
4. Click OK. You are returned to the Services and rates dialog of Figure 5-24.
It is updated to reflect your choice.
Figure 5-23: Services and Rates - Services chosen
Note
The selected ports will be enabled for both sides of the link. You
cannot for example, use ports 1, 3, 5, 7 on one side and 2, 4, 6, 8
on the other.
RADWIN 2000 User Manual
Release 2.5.40
5-22
Installation
Chapter 5
Modulation Rate Selection
You may choose a specific modulation rate or use Adaptive.
Figure 5-24: Services and Rates dialog: Available rates
 To choose a modulation rate:
1. Choose Adaptive or one of the available rates.
2. Click Evaluate to continue or click the TDM Jitter Buffer tab to set the TDM Jitter
Buffer (see next section).
The service is activated as show below:
You are returned to the Services and rates dialog of Figure 5-24.
Setting Monitored Hot Standby Mode
If you are not using Hot Standby Mode, you may skip this section.
To install and use the Hot Standby feature, see Chapter 12. The following procedure can be
used to switch links between primary and secondary or to disable the mode.
 To set the Hot Standby Mode:
1. Click the Hot Standby tab. The following dialog appears:
RADWIN 2000 User Manual
Release 2.5.40
5-23
Installation
Chapter 5
Figure 5-25: Choosing Hot Standby Mode
2. Click the radio button to make this link primary or secondary.
Ethernet Ring
To install and use the Ethernet Ring feature, see Chapter 13.
Ethernet QoS
To install and use the Ethernet QoS feature, see Chapter 25.
Setting the TDM Jitter Buffer
 To set the TDM Jitter Buffer size:
1. Click the TDM Jitter Buffer tab. The following dialog appears:
RADWIN 2000 User Manual
Release 2.5.40
5-24
Installation
Chapter 5
Figure 5-26: TDM Jitter Buffer Configuration
•
Note
•
•
•
The receiver jitter buffer for each site can be enlarged,
thereby increasing system resistance to interference (the
larger the jitter buffer, the longer the interference period
that the system will overcome without TDM errors).
You can also decrease the jitter buffer to decrease the system delay.
The jitter buffer can be configured between 2.0 and 16.0
ms.
After setting the new value you must evaluate the expected
quality. During the evaluation the TBFR (TDM Block Failure
Ratio)bar is displayed. You select either Next, which performs the change or Back to cancel the change. Notice that
the Jitter Buffer is configured per site.
RADWIN 2000 User Manual
Release 2.5.40
5-25
Installation
Chapter 5
Figure 5-27: TDM Jitter Buffer Configuration - TBFR evaluation bar
2. After setting the jitter buffer size, if grayed out, the Evaluate button is enabled while
both Back and Next are disabled as shown in the next figure:
Figure 5-28: Services and TDM delay set - link ready for evaluation
3. You may make any further changes to the Service Configuration or the Jitter
buffer. When you are satisfied, click the Evaluate.
RADWIN 2000 User Manual
Release 2.5.40
5-26
Installation
Chapter 5
The optimum transmission rate for the selected services is evaluated.
Following a short delay for processing, Back and Next are enabled.
4. Click Next to continue.
Note
The transmission rates used by RADWIN 2000 are shown in Table 5-3
above.
Step 7, TDM Clock Configuration
The following dialog is displayed:
Figure 5-29: TDM Parameters Configuration (1)
 To configure TDM clock parameters:
1. For any individual port, click it. For the same parameters for all ports, click
the Select Maximum tag.
•
•
Note
•
Select Maximum will select the maximum number of services that
were configured for the air interface for configuration
Deselect All unconditionally deselects all of the services for configuration
Without selecting anything, right-clicking any port will cause the
appearance of the drop down list of Figure 5-30 below
2. Click Configure. The following drop down list is displayed:
RADWIN 2000 User Manual
Release 2.5.40
5-27
Installation
Chapter 5
Figure 5-30: TDM Parameters Configuration (2)
3. Click the required parameter. Their meanings are as follows:
Please keep in mind that what follows is per port.
Note
Figure 5-31: TDM Parameters
Transparent/Transparent
The clock at Site A regenerates the clock from Site B and
vice versa.
Loop time/Recover
The Site A port receive-clock is used as the transmit-clock
for that port on both sides of the link.
Recover/Loop time
The Site B port receive-clock is used as the transmit-clock
for that port on both sides of the link.
Internal/Recover
RADWIN 2000 User Manual
Release 2.5.40
5-28
Installation
Chapter 5
The Site A port uses its internal oscillator to generate its
transmit clock while the Site B port regenerates the clock
received at the Site A port.
Recover/Internal
The Site B port uses its internal oscillator to generate its
transmit clock while the Site A port regenerates the clock
received at the Site B port.
4. Click Finish to complete the wizard.
Step 8, Installation Summary and Exit
Figure 5-32: Installation Wizard Exit Summary
Click Done to return to the main window.
The main window now reflects the installation:
RADWIN 2000 User Manual
Release 2.5.40
5-29
Installation
Chapter 5
Figure 5-33: Main window of the Manager after installation with loaded trunks
RADWIN 2000 User Manual
Release 2.5.40
5-30
Installation
Chapter 5
Figure 5-34: Main window of the Manager after installation with asymmetric capacity allocation - No HSS
Figure 5-34 shows the results of a 70%/30% Transmission ratio on a lone link (no HSS).
Observe that near 100Mbs is available in either direction
RADWIN 2000 User Manual
Release 2.5.40
5-31
Installation
Chapter 5
Figure 5-35: Main window of the Manager after installation with asymmetric capacity allocation - HSS enabled
Figure 5-35 shows the results of a 70%/30% Transmission ratio on a lone link with HSS.
The allocation is “hard”.
 To verify the installation:
• Verify that the Received Signal Strength (RSS) is according to expected results as
determined by the Link Budget Calculator.
Installation mode, as described above, may be re-entered using Site:A or
Site:B and Installation Mode in the Site Configuration dialog. Some
Installation mode functionality may cause a break in, or degrade link
service.
Caution
If you can accomplish link changes without affecting the service, always
prefer to use Configuration mode, described in Chapter 7.
RADWIN 2000 User Manual
Release 2.5.40
5-32
Chapter 6
The RADWIN Manager:
Main Window
One Manager for all RADWIN Radio Products
The RADWIN Manager application is largely generic to all RADWIN Radio Products.
Functionality differences are minimal according to radio series (WinLink 1000 and RADWIN
2000) capabilities.
The Main Window of the RADWIN Manager
Ensure that the RADWIN Manager is running.
The main window should look similar to that in Figure 6-1:
RADWIN 2000 User Manual
Release 2.5.40
6-1
The RADWIN Manager Toolbar
Chapter 6
Figure 6-1: Main window, Wireless Link is Active
The main window of the RADWIN Manager contains a large amount of information about the
link. Before proceeding to details of link configuration we set out the meaning of each item in
the main window.
The RADWIN Manager Toolbar
In configuration mode, the RADWIN Manager toolbar contains the following buttons:
In Installation mode, Link Configuration is grayed out and Link Installation is open.
The button functions are set out in Table 6-1:
Table 6-1: RADWIN Manager Toolbar
Item
Description
Link Configuration
Changes configuration parameters of an operating wireless link; assigns text files
for storing alarms, statistics and configuration data. This button is disabled
until a link installation has been completed
Link Installation
Performs preliminary configuration of the system. This button is disabled after
the link is installed
Site: 
Opens the Site configuration dialog for Site 1. Same as Configuration | 1
Configure 
RADWIN 2000 User Manual
Release 2.5.40
6-2
Main Menu Functionality
Chapter 6
Table 6-1: RADWIN Manager Toolbar (Continued)
Item
Description
Site: 
Opens the Site configuration dialog for Site 2. Same as Configuration | 2
Configure 
Get Diagnostics
Obtain system information
Clear Counters
Clears TDM error blocks counters. Disabled for Ethernet-only link
Log off
Closes the current session and logs off RADWIN Manager
Exit
Exits RADWIN Manager
Help
Opens Help on the use of contextual online help
Main Menu Functionality
The main menu contains the following items:
The RADWIN Manager menu functionality is displayed in Table 6-2.
Table 6-2: RADWIN Manager main menu functionality
Menu level
Top
+1
Function
+2
Log Off
Return to log-on dialog. Same as Log
Off button
Exit
Exit the RADWIN Manager. Same as
Exit button
Link Configuration
Run the Configuration Wizard. Not
available in Installation Mode
1 Configure 
Opens the Site configuration dialog for
Site 1. Has a path to return to
Installation Mode
2 Configure 
Opens the Site configuration dialog for
Site 2. Has a path to return to
Installation Mode
Link Installation
Runs the Installation Wizard. Not
available in Configuration Mode
File
Configuration
RADWIN 2000 User Manual
Release 2.5.40
Reference
Chapter 7
Chapter 8
Chapter 5
6-3
Elements of the RADWIN Manager Main Window
Chapter 6
Table 6-2: RADWIN Manager main menu functionality (Continued)
Menu level
Top
+1
Performance
Monitoring Report
1 
Shows active alarms for 
2 
Shows active alarms for 
Chapter 9
Recent Events
Displays recent events by site
Software Upgrade
Upgrade ODU firmware
Chapter 15
Spectrum View
Monitor and evaluate spectrum
availability
Chapter 23
Change Band
(Installer only)
Change the link band
Chapter 20
Change Password
Change the log-on password dialog
page 4-8
Tools
Events Log
Clear Events
Clear local events log
Save to File
Save events log file
page 9-17
Preferences
Local preferences dialog
Clear counters
Clear TDM counters
Loopbacks
Set TDM loopbacks
page 9-4
Estimate Eth.
Throughput
Estimate Ethernet throughput by
transmitting full size frames over the
air for 30 sec
page 9-11
Reset
Help
Reference
On screen and printable
Active Alarms
Maintenance
Function
+2
1 
Reset  ODU
2 
Reset  ODU
RADWIN Manager
Help
View help on online help
Link Budget
Calculator
Calculator opened in default browser
Chapter 21
Get Diagnostics
Information
Obtain system information
page 9-1
Check for Updates
Check for updates from the RADWIN
Web site
About RADWIN
Manager
Manager build and system information
Elements of the RADWIN Manager Main Window
Link details pane
The Link details pane on the left is split into three sections, which are largely self explanatory.
The top section summarizes information about the link:
RADWIN 2000 User Manual
Release 2.5.40
6-4
Elements of the RADWIN Manager Main Window
Chapter 6
For Link status possibilities and color codes, see Table 9-2.
The two lower left panels show basic link site details:
The three fields for each site are user definable. See page 8-7.
The Monitor pane
The monitor pane, is the main source of real time information about link performance at both
link sites. It includes the following panes (top to bottom):
•
Radio Interface, Received Signal Strength (RSS) in dBm and Transmission Ratio:
The Dynamic Tx Ratio bar only appears for model RADWIN 2000 C
Note
•
Ethernet Service:
RADWIN 2000 User Manual
Release 2.5.40
6-5
Elements of the RADWIN Manager Main Window
•
Chapter 6
Estimated Ethernet Throughput: The numbers are the current calculated
throughputs at each site. The colored bars (with numbers) indicate the maximum
possible throughput having regard for air conditions.
•
Rx and Tx Rates: The Rx and Tx rates are the receive and transmit rates on the
LAN side of each ODU, not the air side. For a balanced link, the Rx and Tx rates
at the LAN side of Site A will match the Tx and Rx rates at the LAN side of Site B
respectively. In all cases, The LAN side Rx rate shown will be the same as the air
side Tx rate for each individual ODU.
Actual Ethernet traffic received and transmitted rates per site, is in Mbps of Fps,
selectable in the panel title bar.
•
•
TDM Services: IDU-C and new style IDU-E:
•
The title bar enables you to switch between Accumulative and Current view.
•
Immediately below the title bar is displayed the TDM Block Failure Ratio. It is
zeroed by the Clear Counters button in the tool bar.
•
Error block count is shown immediately above the active TDM channels display.
•
The color of the TDM ports reflects their current status:
•
Green - Operational
•
Red - Error: LOS for loss of signal and AIS for Alarm Indication Signal
•
Yellow - Loopback
•
Gray - Inactive
Frequency box: It shows the link frequency. The color of the box indicates the status
•
Green is an active link
•
Red is an inactive link
•
Magenta indicates an authentication or compatibility problem
•
Brown indicates severe compatibility problem
Events Log
RADWIN 2000 User Manual
Release 2.5.40
6-6
Elements of the RADWIN Manager Main Window
Chapter 6
The Events Log, stores alarms generated from both sides of the link and is detailed in Chapter 9.
Status Bar
The Status bar, displays the following icons:
Table 6-3: Status bar indicators
Icon or Label
Purpose
Connectivity
Shows if RADWIN Manager is communicating with the ODU.
Connection mode to the ODU
Connection available
•
Over-the-Air connection - using the IP address of the remote unit.
•
Local connection - direct connection to the IDU without using an IP
address.
•
Network connection - through a LAN
ODU unreachable
IP Address
Log on IP address
Normally encrypted link
Encryption indicator
Unencrypted link - lock open
Link password validation failed. The link is encrypted with default keys.
Service and configuration are unavailable. Change the link password.
Link Lock enabled
Link Lock
Link Lock encrypted
Link Lock mismatch
Ethernet Ring Member
DFS in use
Rescue Alarm
In the event of an active alarm, opens alarms dialog
RADWIN RNMS users will see an additional field showing the IP address of the RNMS server:
RADWIN 2000 User Manual
Release 2.5.40
6-7
Elements of the RADWIN Manager Main Window
RADWIN 2000 User Manual
Release 2.5.40
Chapter 6
6-8
Chapter 7
Configuring the Link
Overview
This chapter describes the link configuration procedure, which is performed after the installation of both sides of the RADWIN 2000 link, as set out in Chapter 5.
Link configuration uses a Link Configuration wizard to redefine the configuration parameters
and fine-tune an operational link. Both sides of the link are configured simultaneously.
Link configuration allows you to configure link parameters, which do not lead to sync loss or
require a reset. Some may change service performance, in respect of which, warnings are displayed.
For ease of use, the Link Configuration wizard follows the same pattern as Link Installation.
You should therefore be familiar with the content of Chapter 5.
The following parameters are configured using the Link Configuration Wizard:
•
System parameters
•
Channel settings
•
Transmission power and antenna settings
•
Service parameters
The Configuration Wizard has seven steps as shown in Table 7-1 below.
RADWIN 2000 User Manual
Release 2.5.40
7-1
Overview
Chapter 7
Table 7-1: Link Configuration Wizard
Wizard welcome
System parameters
RADWIN 2000 User Manual
Release 2.5.40
•
Link ID
•
Site details
Channel settings - ACS
Configuration
HSS settings
Tx Power and antenna
settings, MIMO or
Diversity
Services - Types,
Adaptive or fixed, Jitter
Buffer, MHS, Ethernet
Ring, QoS
Set TDM Clock
Parameters
Wizard summary and
completion
7-2
Configuration
Chapter 7
Configuration
Since configuration functionality is included in the installation, we will briefly review the main
steps and for most part offer references to the corresponding installation step.
Step 1, Start the Wizard
In the tool bar of the RADWIN Manager main window, click the Link Configuration button.
The Link Configuration button is only accessible on a fully installed link as set out in Chapter
5.
The Configuration Wizard opens:
Figure 7-1: Link Configuration Wizard
Click Next to proceed with the configuration procedure.
Step 2, System Parameters
The System dialog box opens:
RADWIN 2000 User Manual
Release 2.5.40
7-3
Configuration
Chapter 7
Figure 7-2: Configuration Wizard, System dialog box
The System attributes may be edited and the Link Password may be changed exactly as in the
corresponding Link Installation step on page 5-5.
Click Next to continue.
Step 3, Channel Settings
Configuring the Channel Settings follows the same pattern as the Installation procedure:
RADWIN 2000 User Manual
Release 2.5.40
7-4
Configuration
Chapter 7
Figure 7-3: Channel Settings dialog box - Automatic Channel Selection
Notice that the operating channel is grayed out. If you use the Reselect Channel button, to
change it, you will be asked for confirmation:
If you accept, then the system will search for the best operating channel:
RADWIN 2000 User Manual
Release 2.5.40
7-5
Configuration
Chapter 7
Figure 7-4: Searching for the best operating channel
The link will return to the status of Figure 7-3 above with a possible change to the operating
channel.
If you work without automatic channel selection, the Channel Settings window looks like this:
Figure 7-5: Channel Settings without automatic channel selection
If you click the Operating Channel drop-down list, the following window appears:
RADWIN 2000 User Manual
Release 2.5.40
7-6
Configuration
Chapter 7
Figure 7-6: Channel frequency options
Selecting one of the frequencies presented returns you to the status of Figure 7-5 with the
appropriate change. If you choose Other..., the following window opens:
Figure 7-7: Choosing an “Other” Operating Channel frequency
The right hand drop-down list (showing the current Operating Channel) allows you to finetune the frequency in increments of ±5MHz within a range of the operating band, which in
this example is 5.740 - 5.835 GHz.
RADWIN 2000 User Manual
Release 2.5.40
7-7
Configuration
Chapter 7
The Channel Bandwidth may also be changed. The available choices are 10, 20 and 40MHz
depending on regulation (see Appendix A).
When you have completed making your choice, click Next to continue.
Step 4, Tx Power and Antenna Settings
The Tx Power and Antenna Settings window is similar to that for Installation:
Figure 7-8: Transmission Power and Antenna Parameters
As in Installation mode, you need to consider three items:
•
Number of antennas at each Link site (1 or 2)
•
Tx Power setting for each one
•
MIMO or Diversity mode
Changing Number of Antennas and Tx Power
TX Power, Antenna Gain and Cable Loss
If you chose to configure either antenna, you are presented with the following window:
RADWIN 2000 User Manual
Release 2.5.40
7-8
Configuration
Chapter 7
Figure 7-9: Antenna configuration dialog with opened type selection
(Recall that we are using an unrealistically low Tx power here because our link in a laboratory.)
So far, the procedure duplicates the corresponding Installation process. If you choose a different antenna type and click OK, you will receive the following cautionary message:
In this context, entering Installation mode causes a service break until it is
restored by running the Installation wizard.
Caution
If you are uncertain, do not do this without expert technical assistance.
You may also change the Required Tx Power, Antenna Gain and Cable Loss. The procedure is
the same as that set out in the Installation procedure on page 5-13.
Switching Between Single and Dual Antennas
Single/Dual Antenna mode selection works precisely the same way as shown on page 5-20.
If you use this option you will receive a warning similar to this:
RADWIN 2000 User Manual
Release 2.5.40
7-9
Configuration
Chapter 7
Switching Between MIMO and Diversity Modes
A similarly worded warning applies to a s switch from Diversity to MIMO mode. The considerations are otherwise no different from those set out in the corresponding Installation step.
When you have completed making your choice, proceed to the Services window.
Step 5, Hub Site Synchronization Settings
Figure 7-10: HSS Settings
The Synchronization Status dialog box displays the current status of each side of the link. See
Chapter 10 for instructions about installing and configuring collocated links. If you do not
require HSS, click Next.
Step 6, Services
Here is the services dialog:
RADWIN 2000 User Manual
Release 2.5.40
7-10
Configuration
Chapter 7
Figure 7-11: Services and Rates dialog
To choose Services, see the corresponding Installation procedure in Chapter 5.
If you are using a link that •
is non-collocated
•
is Ethernet-only
•
uses model RADWIN 2000 C ODUs
then you may use Asymmetric Allocation. You may change the capacity allocation here the
same way as during installation. In place of the IDU box in Figure 7-11, you will see the
Asymmetric Allocation slider:
The procedures for setting the Jitter Buffer and Hot Standby parameters are also the same as
the corresponding procedures in Chapter 5.
Click Next to continue.
Step 7, TDM Clock Configuration
The following dialog is displayed:
RADWIN 2000 User Manual
Release 2.5.40
7-11
Configuration
Chapter 7
Figure 7-12: TDM Parameters Configuration
To configure the TDM Parameters, see the corresponding procedure in Chapter 5.
Step 8, Configuration Summary and Exit
Figure 7-13: Configuration Wizard Exit Summary
Click Done to return to the main window.
RADWIN 2000 User Manual
Release 2.5.40
7-12
Configuration
Chapter 7
The main window now reflects the configuration:
Figure 7-14: Main window of the manager after configuration
RADWIN 2000 User Manual
Release 2.5.40
7-13
Chapter 8
Site Configuration
The Site Configuration dialog panels are used to configure parameters, which may differ
between both sides of the link.
The parameters configured using the Site Configuration dialog panels include (among others):
•
System settings
•
Air interface - Transmit (Tx) power and antenna
•
Hub Site Synchronization status
•
Network management including VLAN
•
Inventory - link hardware and software model details
•
Security settings
•
Date and time
•
Ethernet service settings
•
TDM Hot Standby status
•
External alarms settings
•
Operations - Revert to factory settings
The Operations dialog offers a “doorway” to jump into installation mode.
The Site Configuration dialog has its own main menu with the following extra functionality:
•
Backup ODU software
•
Restore ODU software or configuration from a backup file
•
Refresh the current panel
•
Enable/disable the site ODU buzzer
•
Jump back into installation mode keeping current configuration settings
Configuring the Site
Editing the Configuration Parameters by Site
You can edit the configuration parameters for each site individually. The following functions
are available from the left side of the dialog box.
RADWIN 2000 User Manual
Release 2.5.40
8-1
Editing the Configuration Parameters by Site
Chapter 8
Figure 8-1: Configuration Dialog Box
Functions on the left of the dialog box:
System
Edit the contact person and location details. View the system
details
Air Interface
Change the Tx Power, cable loss, antenna type and settings.
View HSS settings
Management
Configure the IP address, Subnet Mask, Default Gateway, Trap
Destination and VLAN
Inventory
View the hardware and software inventory (product
identification, versions, MAC address and serial number)
Security
Change the Community Values and the Link Password. Set Link
Lock.
Date and Time
Set the date and time of the link from an NTP servers or from the
managing computer
Advanced
Choose Hub or Bridge ODU mode, IDU aging time, set the
Ethernet ports configuration, set max. information rate, TDM
MHS status, set the external alarm inputs, restore factory
settings, set IDU detection mode.
Functions at the top of the dialog box:
Backup
Save the current ODU software to a file
Restore
Restore an ODU’s software or configuration from a backup file
created by the backup facility
Refresh
Refresh current panel with latest values
Installation Mode
Return to Installation Mode for the entire link.
Selecting the Mute check box before clicking the Install Mode
button mutes the Beeper.
RADWIN 2000 User Manual
Release 2.5.40
8-2
Viewing System Details
Buzzer
Chapter 8
Mutes the alignment tone in installation mode. Reactivate the
beeper during alignment.
 To edit the Configuration Parameters:
1. Click the required site button on the main tool bar of the RADWIN Manager
OR
Click Configuration from the main menu and choose a site to configure.
The Configuration dialog box opens (see Figure 8-1 above).
2. Choose the appropriate item in the left hand list to open a dialog box.
3. Click Apply to save changes.
In subsequent instructions, we will simply say “Choose a site to configure” on the understanding that the foregoing procedure is implied.
Viewing System Details
This is the first window displayed - as depicted above. You can edit the contact details and
site names.
Viewing Air Interface Details
Click the Air Interface item in the left hand list. A window similar to the following appears:
Figure 8-2: Air interface details
Changing the Transmit Power
Each site can have a different Tx Power level.
RADWIN 2000 User Manual
Release 2.5.40
8-3
Hub Site Sync
Chapter 8
 To change the Transmit Power:
1. Choose a site to configure.
The Configuration dialog box opens.
2. Choose Air Interface (see Figure 8-3).
3. Choose the required Transmit (Tx) Power Level.
4. Click Apply to save the changes.
Figure 8-3: Changing the Transmit Power
For detailed explanation about the relationship between these parameters, see page 5-13 to
5-21.
Caution
Changing the Tx Power will affect service quality. The same considerations
apply here as were noted in the Installation procedure on page 5-17.
Hub Site Sync
Here you can view the HSS status:
RADWIN 2000 User Manual
Release 2.5.40
8-4
Site Management: IP Address, VLAN and Protocol
Chapter 8
Figure 8-4: HSS Status
Site Management: IP Address, VLAN and Protocol
Configuring the ODU Address
Each site must be configured separately. For an over-the air configuration, first configure site
B then site A so as to avoid lockout. See Chapter 19 for detailed instructions about the best
way to do this on-site.
See Chapter 14 for further details about VLAN Functionality for RADWIN 2000.
 To define the Management Addresses:
1. Choose a site to configure.
The Configuration dialog box opens:
RADWIN 2000 User Manual
Release 2.5.40
8-5
Configuring VLAN Settings
Chapter 8
Figure 8-5: Management Addresses - Site Configuration dialog box
5. Choose Management.
6. Enter the IP address of the ODU in the IP Address field.
Note
If performing configuration from the RADWIN Manager, the IP address is
that entered from the Login window.
7. Enter the Subnet Mask.
8. Enter the Default Gateway.
9. Enter the Trap Destination. This could be the IP address of the managing computer.
The events log will be stored at this address.
10. Click Apply to save the changes.
Configuring VLAN Settings
Caution
VLAN IDs are used by RADWIN products in three separate contexts:
Management VLAN, Traffic VLAN and Ethernet Ring. It is recommended that
you use different VLAN IDs for each context.
VLAN Management enables separation of user traffic from management traffic whenever such
separation is required. It is recommended that both sides of the link be configured with different VLAN IDs for management traffic. (This reduces your chances of accidentally locking
yourself out of the link.)
 To enable VLAN management:
1. Click Configuration from the main menu.
RADWIN 2000 User Manual
Release 2.5.40
8-6
Lost or forgotten VLAN ID
Chapter 8
2. Choose a site to configure. If you are configuring both sites, choose site B first to
avoid locking yourself out.
3. Choose Management.
4. Open the VLAN tab.
5. Check the Enabled box.
6. Enter a VLAN ID. Its value should be between 1 and 4094.
After entering the VLAN ID, only packets with the specified VLAN ID are processed
for management purposes by the ODU. This includes all the protocols supported by
the ODU (ICMP, SNMP, TELNET and NTP). The VLAN priority is used for the traffic
sent from the ODU to the managing computer. Using VLAN for management traffic
affects all types of management connections (local, network and over the air).
7. Enter a Priority number between 0 and 7.
8. Change the VLAN ID and Priority of the managing computer NIC to be the same as
those of steps 6 and 7 respectively.
Caution
Changing this parameter causes the RADWIN Manager to immediately
disconnect. To avoid inconvenience, you should verify the change by
setting the VLAN only to one ODU, and only after verifying proper
management operation, change the other ODU VLAN setting.
9. Click Apply or OK.
Figure 8-6: Configuring management traffic VLAN Settings
Lost or forgotten VLAN ID
If the VLAN ID is forgotten or there is no VLAN traffic connected to the ODU, then reset the
relevant ODU.
RADWIN 2000 User Manual
Release 2.5.40
8-7
Enable / Disable Telnet Access
Chapter 8
During the first two minutes of connection, the ODU uses management packets both with and
without VLAN. You may use this period to reconfigure the VLAN ID and priority.
Enable / Disable Telnet Access
For a link managed in a network, direct access to an ODU using Telnet is considered to be a
security breach. Telnet access may be enabled or disabled by clicking the Protocol tab and
enabling/disabling Telnet access using the Telnet check-box:
Figure 8-7: Enable/Disable Telnet Access
Displaying the Inventory
 To view the inventory data
1. Choose a site from the main menu.
The Configuration dialog box opens.
2. Choose Inventory.
Figure 8-8: Inventory window
RADWIN 2000 User Manual
Release 2.5.40
8-8
Security Features
Chapter 8
Security Features
The Security dialog enables you to change the Link Password and the SNMP Community
strings and use the Link Lock feature:
Figure 8-9: Available security features
Changing the Link Password
This item is only available when the link is down. Otherwise, it works the same way as the
corresponding item on page 5-8.
RADWIN Manager Community Strings
The ODU communicates with the RADWIN Manager using SNMPv1 protocol. The protocol
defines three types of communities:
•
Read-Only for retrieving information from the ODU
•
Read-Write to configure and control the ODU
•
Trap used by the ODU to issue traps.
The Community string must be entered at log on. The user must know the password and the
correct Community string to gain access to the system. A user may have read-only privileges.
It is not possible to manage the ODU if the read-write or the read Community values are forgotten. A new Community value may be obtained from RADWIN Customer Support for the
purpose of setting new Community. You must also have available the serial number or the
MAC address of the ODU.
The read-write Community strings and read-only Community strings have a minimum of five
alphanumeric characters. (bru1 and bru4097 are not permitted). Changing the trap Community is optional and is done by clicking the check box.
RADWIN 2000 User Manual
Release 2.5.40
8-9
RADWIN Manager Community Strings
Chapter 8
Editing Community Strings
The Community change dialog box is available from the Configuration | Security tab. Both
read-write and read-only communities must be defined.
On logging on for the first time, use the following as the current Community:
•
For Read-Write Community, use netman.
•
For Read-Only Community, use public.
•
For Trap Community, use public
 To change a Community string:
1. From the Configuration dialog box, choose the Security tab.
2. Type the current read-write Community (default is netman).
3. Choose the communities to be changed by clicking the check box.
4. Type the new Community string and re-type to confirm. A community string must
contain at least five and no more than 32 characters excluding SPACE, TAB, and any
of “>#@|*?;."
5. Click OK to save.
Figure 8-10: Changing the Community String
Forgotten Community string
If the read-write Community string is unknown, an alternative Community key can be used.
The alternative Community key is unique per ODU and can be used only to change the Community strings. The alternative Community key is supplied with the product, and should be
kept in a safe place.
If both the read-write Community and the alternative Community key are unavailable, then
an alternative Community key can be obtained from RADWIN Customer Support using the
ODU serial number or MAC address. The serial number is located on the product label. The
serial number and the MAC address are displayed in the Site Configuration inventory tab.
When you have the alternative Community key, click the Forgot Community button and
enter the Alternative Community key (Figure 8-11). Then change the read-write Community
string.
RADWIN 2000 User Manual
Release 2.5.40
8-10
Link Lock Security Feature
Chapter 8
Figure 8-11: Alternative Community Dialog box
Link Lock Security Feature
Link Lock is a part of RADWIN’s security concept intended to meet a form of abuse
encountered in the field. It is designed to prevent the situation where a remote ODU
can be stolen and used as a “pirate” link to steal services or information. The Link
Lock feature actually locks the local ODU to be synchronized ONLY to specific remote
ODU. It is a site oriented feature.
The lock can only be set from a live link. It is based on MAC authentication and is site
oriented and activated on a per ODU basis. For example, if you lock the Site B ODU to
the Site A ODU, you must still lock the Site A ODU to the Site B ODU to ensure
complete two way locking.
Link Lock can only be removed when the link is unsynchronized. In such a case, an
alarm is raised by the RADWIN Manager.
 To enable Link Lock:
1. Click Site A on the main tool bar.
2. Choose the Security tab. The following window is displayed:
RADWIN 2000 User Manual
Release 2.5.40
8-11
Link Lock Security Feature
Chapter 8
3. Click the Link Lock check-box and then OK. You are asked to confirm the
lock:
4. Click the Yes button and you are returned to the main window of the
RADWIN Manager.
Observe that a link icon is now displayed in the status bar on the bottom right of the
RADWIN Manager window.
The link to the remote unit is now locked. If you repeat steps 1 and 2 above, the
Security screen will look like this:
RADWIN 2000 User Manual
Release 2.5.40
8-12
Setting the Date and Time
Chapter 8
The Link Lock check-box is now unavailable.
5. If required, repeat the procedure for Site B.
Note
To revert the Link Lock status to unlocked, power down each ODU
in turn. Use the above procedure to uncheck the Link Lock status
box for the live ODU.
A simple ODU reset at either end will restore the link to its previous
locked or unlocked state.
Setting the Date and Time
The ODU maintains a date and time. The date and time should be synchronized with any Network Time Protocol (NTP) version 3 compatible server.
During power-up the ODU attempts to configure the initial date and time using an NTP Server.
If the server IP address is not configured or is not reachable, a default time is set.
When configuring the NTP Server IP address, you should also configure the offset from the
Universal Coordinated Time (UTC). If there is no server available, you can either set the date
and time, or you can set it to use the date and time from the managing computer. Note that
manual setting is not recommended since it will be overridden by a reset, power up, or synchronization with an NTP Server.
The NTP uses UDP port 123. If a firewall is configured between the ODU
and the NTP Server this port must be opened.
Note
It can take up to 8 minutes for the NTP to synchronize the ODU date and
time.
RADWIN 2000 User Manual
Release 2.5.40
8-13
Setting the Date and Time
Chapter 8
 To set the date and time:
1. Determine the IP address of the NTP server to be used.
2. Test it for connectivity using the command (Windows XP), for example:
w32tm /stripchart /computer:216.218.192.202
You should get a continuous response of times, each a few seconds apart.
3. Choose a site to configure.
The Configuration dialog box opens.
4. Choose Date & Time:
Figure 8-12: Date and Time Configuration
5. If entering an IP address for the NTP Server, click Clear, and then enter the new
address.
6. Set your site Offset value in minutes ahead or behind GMT1.
7. To manually set the date and time, click Change and edit the new values.
Figure 8-13: Change Date and Time
If you used an NTP Server, you will see a window like this:
1. Greenwich Mean Time
RADWIN 2000 User Manual
Release 2.5.40
8-14
Ethernet Properties
Chapter 8
Figure 8-14: Date and Time configured from an NTP Server
8. Click OK to return to the Configuration dialog.
Ethernet Properties
Configuring the Bridge
Bridge configuration is required in various network topologies, such as protection (Ethernet
1+1) and ring applications. The bridge configuration parameters are located under the
Advanced tab of the Site Configuration dialog box:
RADWIN 2000 User Manual
Release 2.5.40
8-15
Configuring the Bridge
Chapter 8
Figure 8-15: Bridge, VLAN and MIR Configuration
ODU Mode
RADWIN 2000 C-Series ODU products work in Hub mode only. The bridge
capability is built in to the IDU-C (it is not configurable). If an IDU-C is
connected to an RADWIN 2000 C ODU, then the IDU-C performs the
bridging.
Note
This parameter controls the ODU mode with two optional values:
•
Hub Mode - in Hub mode the ODU transparently forwards all packets over the wireless
link.
•
Bridge Mode - In Bridge mode the ODU performs both learning and aging, forwarding
only relevant packets over the wireless link. The aging time of the ODU is fixed at 300
seconds.
Changing these modes requires system reset.
Note
IDU Aging time
This parameter controls the IDU aging time.
The aging time parameter controls the time after which each MAC address is dropped from
the MAC address learning table.
The default value is 300 seconds.
•
•
Note
Any change to these parameters is effective immediately.
Each side of the link can be configured separately, with different
aging times.
RADWIN 2000 User Manual
Release 2.5.40
8-16
Configuring Ethernet Ports Mode
Chapter 8
The following table shows the appropriate configuration for several common scenarios. Both
link sites must be configured with the same parameter:
Table 8-1: ODU mode configuration for common scenarios
Scenario
ODU
Mode
IDU Aging
Time
Standard (default) Configuration for Ethernet
Applications
Bridge
300 sec
Rapid network topology changes where fast
aging is required
Hub
1 sec
Configuring Ethernet Ports Mode
The ODU Ethernet port is configured to auto-detect by default and may not be changed.
The ODU Ethernet port mode is configurable for line speed (10/100BaseT) and duplex mode
(half or full duplex).
An Auto Detect feature is provided, whereby the line speed and duplex mode are detected
automatically using auto-negotiation. Use manual configuration when attached external
equipment does not support auto-negotiation. The default setting is Auto Detect.
Caution
You should not reconfigure the port that is used for the managing computer
connection, since a wrong configuration can cause a management
disconnection or Ethernet services interruption.
 To configure the Ethernet Mode:
1. From the Configuration menu, choose the site to configure.
The Site Configuration dialog box opens.
2. Click Advanced | Ethernet.
3. In the Ethernet Ports Configuration pane, use the drop-down menu to choose the
configuration.
4. Click Apply to save the changes.
It is possible to close the Ethernet service by disconnecting the Ethernet
port.
If you close the port, you may subsequently be unable to access the
device. If this should occur, a workaround is as follows:
Note
•
•
•
Connect the system from the remote site
Connect via other Ethernet port (of the IDU)
Power down the equipment and connect immediately after power
up (the fastest way is to enter install mode)
VLAN Tagging for Ethernet Service: Configuration
If you are using a PoE device, this feature is unavailable. You may skip this section.
RADWIN 2000 User Manual
Release 2.5.40
8-17
VLAN Tagging for Ethernet Service: Configuration
Caution
Chapter 8
VLAN IDs are used by RADWIN products in three separate contexts:
Management VLAN, Traffic VLAN and Ethernet Ring. It is recommended that
you use different VLAN IDs for each context.
To set up VLAN tagging for Ethernet Service, click the VLAN Configuration... button in
Figure 8-15. The following window is displayed:
Figure 8-16: VLAN tag settings
If you are using a new style IDU-E, the SFP row will not appear.
Note
The choices for Ingress Mode are -
and for Egress Mode are -
RADWIN 2000 User Manual
Release 2.5.40
8-18
Setting the Maximum Information Rate (MIR)
Chapter 8
The details of setting up VLAN tagging require advanced network management skills beyond
the scope of this manual. Further information for the Network Manager is provided in Chapter 14.
Setting the Maximum Information Rate (MIR)
What is the MIR
The maximum Ethernet throughput of the link (MIR) can be limited. The default setting is
Best Effort (see Figure 8-15 above), where the highest information rate available for the link
conditions and settings is used.
What is it for
The MIR setting limits the throughput for Ethernet service. It does not affect the capacity of
TDM services.
If the Link Budget Calculator or air conditions limit the capacity to X Mbps, and suppose that
you use Y (< X) Mbps for TDM services, then you are left with X - Y=Z Mbps for Ethernet.
Suppose for example, that Z = 20 Mbps.
As a Service Provider, you can decide to sell a package based on 10Mbps and charge $P1 for
it, or 15 Mbps for $P2 > $P1.
The MIR setting allows you do this.
The default value is “best effort” which will give Z above.
The minimum value is 256 Mbps.
The maximum value will be the minimum between Z above and -
Note
•
•
•
10 Mbps for RADWIN 2000 PDH
50 Mbps for RADWIN 2000 L
100 Mbps for RADWIN 2000 C
The MIR setting is independent per direction.
 To limit the Ethernet information rate:
1. From the Configuration menu, choose the site to reconfigure.
2. Click Advanced | Ethernet
The Configuration dialog box opens.
RADWIN 2000 User Manual
Release 2.5.40
8-19
Setting the Maximum Information Rate (MIR)
Chapter 8
Figure 8-17: Bridge Configuration - Site Configuration dialog box
3. In the Information Rate pane, use the drop-down menu to choose the MIR.
Figure 8-18: Ethernet MIR - Throughput selection
4. Choose Other to define the throughput with 1 Kbps resolution
5. Choose Best Effort for the highest information rate possible for the link conditions
and settings
6. Click Apply to save the changes.
RADWIN 2000 User Manual
Release 2.5.40
8-20
TDM MHS Status
Chapter 8
TDM MHS Status
Here you can see the TDM MHS status. There is nothing to set.
Figure 8-19: TDM MHS status
Setting External Alarm Inputs
The IDU-C and the new style IDU-E have four external alarm inputs and four external alarm
outputs in the form of dry-contact relays. The Alarm interface is located on the front panel of
the IDU-C and is a 25-pin D-type female connector. See Appendix B, for wiring specifications
and pinout. You may enable or disable each of the alarms and configure the alarm description
text appearing in the alarm trap message. The ODU sends the alarm within less than a second from actual alarm trigger.
 To set the external alarm inputs:
1. Choose External Alarms from the Site Configuration window.
RADWIN 2000 User Manual
Release 2.5.40
8-21
Resetting
Chapter 8
Figure 8-20: External Alarms Configuration
2. Choose an alarm and set its mode to Enabled or Disabled
3. Enter a description of the alarms in the text field.
4. Click Apply to save.
5. Click OK to exit from the dialog.
Resetting
You may reset the link, preserving the current configuration, or reset to factory defaults.
Resetting the link causes service disconnection.
Caution
To maintain the connection between the managing computer and
the link, first reset Site B.
 To reset the link preserving current configuration:
1. From Maintenance on the main window, reset the remote unit.
2. From Maintenance on the main window, reset the local unit.
 To reset to Factory Defaults
1. Choose either of the sites to be reset. The Configuration dialog box opens.
2. Choose Operations in the Configuration dialog box.
RADWIN 2000 User Manual
Release 2.5.40
8-22
IDU Detection
Chapter 8
Figure 8-21: Site Configuration - Reset to factory defaults
3. Click the Restore Defaults button.
A message box asking if you want to restore factory default settings appears.
4. Click the check box if you want to keep the current IP address settings.
5. Click Yes to continue.
After a few moments the site will be reset and you will need to log on to it to reinstall the link.
IDU Detection
An ODU always tries to detect the IDU to which it is connected. IDU Detection is effected by
an IDU responding to special ODU packets.
If a PoE device is in use, the detection packets spread to the containing network and may
cause flooding. In such a case, the IDU Detection feature, (Figure 8-21), should be disabled.
RADWIN 2000 User Manual
Release 2.5.40
8-23
Backup/Restore of ODU Software Files
Chapter 8
To disable IDU Detection Mode, just toggle the check box in Figure 8-21.
Backup/Restore of ODU Software Files
Backup ODU Software to a File
RADWIN Manager allows you to backup the ODU software of both units of a link to the managing computer as binary files. Each site is backed up in a separate file. Backup files are
matched to the MAC address of the site ODU. The default backup file name is constructed
from the ODU IP address and the date as in the following example:
Backup of Site A as used in our examples:
192.168.1.101_1.12.2009.backup
If you perform more than one backup on a given date you will need to change the file name
to something like this:
192.168.1.101_1.12.2009_00.backup
192.168.1.101_1.12.2009_01.backup
...
 To backup the ODU software a file:
1. Choose a site to back up. The Site Configuration dialog box opens.
2. Click Backup.
3. In the Save As dialog box, indicate in which folder and under what name configuration file is to be saved, and click Save.
Restoring ODU Software or Configuration
Backup files can be uploaded from the managing computer. You may choose a full software
restore or configuration-only restore.
 To restore from a backup file:
1. Choose a site to restore (from a previous backup).
The Site Configuration dialog box opens.
2. Click Restore. You are offered the choice of a Full or Configuration Restore as
shown:
3. Click the required Restore type. You are then offered a standard Open File dialog
box.
RADWIN 2000 User Manual
Release 2.5.40
8-24
Muting the alignment tone buzzer
Chapter 8
4. From the Open File dialog box, navigate to your backup storage area and choose file
to upload. Click OK.
Muting the alignment tone buzzer
The ODU alignment tone becomes audible as soon as power is supplied, and continues until
the ODUs are aligned and the link established.
It is possible to mute the tone during regular operation of the link. It must be enabled when
performing the alignment procedure.
 To mute the alignment tone buzzer:
1. Choose a site. The Configuration dialog box opens.
2. In the Configuration dialog box, click the Buzzer button.
Figure 8-22: Alignment tone buzzer states
3. Click Off. The tone is disabled.
 To restore the alignment tone buzzer:
1. Choose a site. The Configuration dialog box opens.
2. Click On to have the buzzer beep continuously or Auto to have the buzzer beep only
in install mode.
Configuration with Telnet
A Telnet terminal can be used to configure and monitor the RADWIN 2000.
To start a Telnet session, use telnet .
For example, if you run Telnet as follows,
telnet 192.168.1.101
you will be asked for a user name and password.
The Telnet log on user name is the password that you used to enter the RADWIN Manager
(for example, the default: admin). The Telnet password is the corresponding Community
string (default: netman).
RADWIN 2000 User Manual
Release 2.5.40
8-25
Configuration with Telnet
Chapter 8
Figure 8-23: Telnet session log on
A Read-Only Community string allows display only whereas a Read-Write Community string
allows display and set commands.
Supported Telnet commands are shown in Table 8-2. Note that some of the commands are
model-specific. For example, TDM commands will not apply to Ethernet only and PoE based
links.
Table 8-2: Telnet Commands Summary
Command
Explanation
display inventory
Displays ODU product name, Name, Location, hardware and software
revisions, uptime, MAC address, IDU product name, IDU software and
hardware revisions
display management
Displays IP, Subnet, Gateway, Traps table
display link
Displays State, Link ID, Channel BW, RSS, TSL, Frequency/ACS, DFS,
Rate/ARA, Distance
display ethernet
Displays Bridge Mode, Aging time, Port table (State, Status and action)
display tdm
Displays Clock Mode, Master Clock Mode, Current Clock, Quality, TDM
table (Line status, Error Blocks)
display ntp
Displays Time, Server and Offset
display PM  
set ip   
Set the ODU IP address, subnet mask and gateway. The user must reset
the ODU after the command completion
set trap   
Set a specific trap from the traps table (e.g. set trap 3 192.168.1.101
162)
set readpw  
Set the read access password (Read Community)
set writepw  
Set the read-write access password (Read-Write Community)
set trappw  
Set the trap Community string
set buzzer 
Toggle the buzzer mode (0 – off, 1 – on)
set tpc
Set the ODU Tx Power. If a wrong value is entered, both min and max
values shall be displayed in the error reply
set bridge 
Set the ODU bridge mode (0 – off, 1 – on)
set name 
Set the name of the link
set location 
Set the name of the location
RADWIN 2000 User Manual
Release 2.5.40
8-26
Configuration with Telnet
Chapter 8
Table 8-2: Telnet Commands Summary (Continued)
Command
Explanation
set contact 
Set the name of the site manager
set 
Set Link ID
set ethernet 

Set the mode and speed of each Ethernet port
reboot
Resets both the IDU and the ODU. The user is warned that the command
will reset the ODU. A new Telnet session to the ODU may be opened
after the reset is complete. (Watch the IDU LEDs.)
help
Displays the available commands
Figure 8-24, below, shows the available Telnet commands using the help command.
admin@192.168.1.101-> Type "help" for help.
admin@192.168.1.101-> help
Display commands
display inventory
display management
display link
display ethernet
display tdm
display ntp
display PM 

display bands
Set - immediate commands
set ip   
set trap   
set readpw  
set writepw  
set trappw  
set buzzer 
set tpc 
set name 
set location 
set contact 
set ethernet  
reboot
help
Set - reset required commands
set ssid 
set rate 
set bridge 
Command "help" finished OK.
Figure 8-24: Telnet Management window
RADWIN 2000 User Manual
Release 2.5.40
8-27
Chapter 9
Monitoring and
Diagnostics
The RADWIN Manager application enables you to monitor the link, as well as perform diagnostic operations such as loopback tests.
This chapter covers:
•
Retrieving link information
•
Link compatibility issues
•
TDM port loopbacks
•
Reinstalling and realigning a link
•
Link Budget Calculator
•
Performance monitoring
•
Throughput checking
•
Events, alarms and Traps
•
Reverting alert messages
•
Remote power fail indication
•
Troubleshooting
•
Replacing an ODU
•
Restoring to factory setup
•
Online help
•
Obtaining support
Retrieving Link Information (Get Diagnostics)
The Get Diagnostics feature collects and writes all link and Manager information (from both
sites) into a text file. The file information can be used for diagnostics and should be sent to
RADWIN Customer Support to speed up assistance.
RADWIN 2000 User Manual
Release 2.5.40
9-1
Retrieving Link Information (Get Diagnostics)
Chapter 9
The following table lists link and system information that can be monitored.
Table 9-1: Get Diagnostics Data and Description
Data
Description
System Data
General information about the system
Link Information
Information about the link properties
•
List of system events including those from other sites if this
site is defined as the trap destination
•
Last 256 events from both sites
Events Log
Site Configuration
Data about the site parameters
Active Alarms
List of active alarms
Performance Monitor
Network performance data over defined time periods
Monitor
Detailed event data record
Spectrum View
Data from last Spectrum View run
 To get diagnostics
1. From the Help menu, choose Get Diagnostics Information.
Figure 9-1: Get Diagnostics Dialog Box
2. Select or deselect the data options. If the file is to be sent to RADWIN Customer Support leave all options checked.
3. Click File Path to specify the folder in which you want to save the file and then click
Start to save the information.
The file is saved in the specified folder as Diagnostics Information.txt
RADWIN 2000 User Manual
Release 2.5.40
9-2
Link Compatibility
Chapter 9
Link Compatibility
Link Compatibility indicates the version compatibility using software traps. As new hardware
or software is added to existing networks compatibility issues may arise. An incompatibility
issue is indicated to the user by a change of color of the Link Status box on the Main Menu
window. Trap messages (can be viewed in the Events Log) indicate the problems or limitations and suggest upgrades when appropriate.
The following Link Status messages are given:
fullCompatibility - different software versions were detected that are fully compatible. The
message indicates that an upgrade is available.
restrictedCompatibility - different software versions were detected that operate correctly.
However, new features are not supported.
softwareUpgradeRequired - different software versions were detected allowing limited operation. The message is, that a software upgrade is required.
versionsIncompatibility - different software versions were detected that are incompatible. You
need to perform local upgrades.
Table 9-2: Link Compatibility Trap Messages
Link State
Link State
text
Link Status
Color
Site Description
fullCompatibility
Active
Green
Software Upgrade
Available
restrictedCompatibility
Active Software
Version
mismatch
Magenta
(Same as
authenticatio
n error)
Software Upgrade
Recommended
softwareUpgradeRequired
Active –
Software
Upgrade
Required
Brown
(Major)
Software Upgrade
Required
versionsIncompatibility
Not Active Software
Upgrade
Required
Red
Local Software
Upgrade Required
TDM Loopbacks
Internal and external loopbacks on both sites of a link are used to test the TDM
connections
 To activate a loopback:
1. From the Maintenance menu, choose Loopbacks... or right-click the TDM
display in the main window.
The Loopbacks dialog box appears:
RADWIN 2000 User Manual
Release 2.5.40
9-3
TDM Loopbacks
Chapter 9
Figure 9-2: Loopback configuration box
2. From the active ports, click those required for loopback activation. The selected port
icons change color to light blue as in the following example:
Figure 9-3: Loopback configuration box with one Site A port selected
3. Click configure to choose a loopback mode:
Figure 9-4: Loopback options
4. Click the required loopback mode.
RADWIN 2000 User Manual
Release 2.5.40
9-4
TDM Loopbacks
Chapter 9
Figure 9-5: Loopback defined
5. Click OK to activate the selected loopback(s).
This activates selected loopback(s). The corresponding service port icon
changes color and appearance to indicate an active loopback.
Figure 9-6: Site A port 2 set to loopback
 To deactivate a loopback:
• Return to the situation of Figure 9-4 and click None.
When a loopback is deactivated, the corresponding icon in Figure 9-6
reverts to its previous state (like the right side of the figure).
RADWIN 2000 User Manual
Release 2.5.40
9-5
Local Line Loopback
Chapter 9
Local Line Loopback
A Local line loopback can be set to test the local E1/T1 port and its connection to local side
user equipment. In this mode, data coming from the local user equipment is looped back to
it. This loopback is initiated from a managing computer connected to the local unit.
Figure 9-7: Local Line Loopback
Remote Reverse Loopback
A remote reverse loopback can be set to test connection between the local and remote units
and between the local E1/T1 port and its connection to the local user equipment. In this
mode, data coming from the local user equipment is looped back at the remote side. This
loopback is initiated from a managing computer connected to the local unit.
Figure 9-8: Remote Reverse Loopback
Remote Line Loopback
The remote unit can be set to a line loopback to test the remote E1/T1 port and its connection to the remote side user equipment. In this mode, data coming from the remote user
equipment is looped back to it locally. This loopback is initiated by the managing computer
connected to the local unit.
RADWIN 2000 User Manual
Release 2.5.40
9-6
Local Internal Loopback
Chapter 9
Figure 9-9: Remote Line Loopback
Local Internal Loopback
The local unit can be set to close a remote loopback to test connection between the local and
remote units and between the remote E1/T1 port and its connection to the remote user
equipment. In this mode, data coming from the remote user equipment is looped back to it
locally. This loopback is initiated by the managing computer connected to the local unit.
Figure 9-10: Local Reverse Loopback
Reinstalling and Realigning a Link
It may be necessary to reinstall the link if the ODUs need to be realigned.
Note
Activating Install Mode causes both sites to go into install mode, causing
disruption in service for approximately fifteen seconds.
 To reinstall the link:
1. Choose a site.
The Configuration dialog box opens.
2. In the Configuration dialog box, click the Install Mode button.
RADWIN 2000 User Manual
Release 2.5.40
9-7
The Link Budget Calculator
Chapter 9
A message box asking if you want to enter install mode appears.
3. Click Yes to continue.
The system enters Install mode and the alignment tone becomes audible.
4. Realign the ODUs and start the Installation wizard (see Chapter 5).
The Link Budget Calculator
The Link Budget Calculator is part of the RADWIN Manager software and is found in the Help
menu. This useful utility enables you to calculate the expected performance of the wireless
link and the possible configurations for a specific link range including antenna size, cable loss
and climate conditions. For full details, see Chapter 21.
Throughput Checking
In this mode, RADWIN 2000 estimates Ethernet throughput by filling frames over the air to
maximum for 30 seconds. This mode should not influence service.
 To use Throughput Checking:
1. At the main menu, click Maintenance | Estimated Eth. Throughput. A confirmation message appears:
2. Click Yes to continue. The Ethernet services area changes appearance and the estimated throughput is displayed:
At the end of 30 seconds, the display reverts to normal.
Performance Monitoring
RADWIN 2000 Performance Monitoring constantly monitors traffic over the radio link and collects statistics data for the air interface, TDM and Ethernet ports. It does so continuously,
even when the RADWIN Manager is not connected.
Two types of logs are recorded:
•
Monitor Log that records statistics on traffic rate and radio signal strength.
•
Events Log that records when the rates fall above or below a predefined threshold.
See page 9-13 below.
RADWIN 2000 User Manual
Release 2.5.40
9-8
The Monitor Log
Chapter 9
Both the statistics Monitor log and events log can be saved as text files.
The Monitor Log
The Monitor Log records performance statistics for predefined intervals. You can save the
monitor log to a text file, as well as display the information in an on-screen report.
Saving the Monitor Log
You can save the recorded Monitor Log statistics to a text file.
 To save the monitor log:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears:
Figure 9-11: Preferences dialog box
2. Click the Monitor Tab.
3. Select the file to save.
4. Click the check box to open the file for saving.
5. Click the
button and in the Select File dialog box indicate in which folder and
under what name the monitor log file is to be saved.
6. Set the time interval for adding data to the file.
7. Click OK to save the file.
Viewing Performance Reports
The Performance Monitor Report displays performance views of each of the interfaces.
 To obtain performance monitoring reports:
1. From the main menu, choose Tools | Performance Monitoring Report ...
You are presented with the following window:
RADWIN 2000 User Manual
Release 2.5.40
9-9
The Monitor Log
Chapter 9
Figure 9-12: Basic Performance Monitoring Report
2. Choose a report type from the left panel and click the Get Data toolbar button. For
example, if you choose Site A, Air and Current, you will be offered a report looking
like this:
Figure 9-13: A typical Performance Monitoring Report based on 15 minute intervals
Notice the Min RSL value of -100 on the fourth line. It Indicates that during the interval 12:30 to 12:45, there was a link sync loss. The next figure shows the effect of a
reset between 14:15 and 14:30.
RADWIN 2000 User Manual
Release 2.5.40
9-10
The Monitor Log
Chapter 9
Figure 9-14: Performance Monitoring Report showing the effect of a Reset
The prior data is invalidated as shown by the red crosses in the left hand column.
Further, Min and Max RSL for the invalidated period is set to zero.
3. Click the Selection Pane icon to toggle the side panel on or off.
The other reports look similar. Here is a detailed description of the reports and their fields:
Several performance data occurrences are collected for each of the interfaces (ES, SES, and
UAS), as well as specific data per Interface type (e.g., Tx and Rx bytes for Ethernet). For the
Air Interface, user defined thresholds data are collected. Refer to Table 9-3 and Table 9-4
below.
Data is collected and selectively displayed based on three time intervals as selected by the
Interval radio buttons:
•
Current (t=0)
•
15 minutes Intervals
•
Daily
Table 9-3: Explanation of performance data
Data type
Generic PM Data
Reported Value
Explanation
UAS – Unavailable
Seconds
Seconds in which the interface was out of service.
Raw ES – Raw Errored
Seconds
The number of seconds in which there was at least one error
block. Note that the notion of an error block is different per
interface.
SES – Severe Errored
Seconds
The number of seconds in which the service quality was low
(the quality is different per type of interface and determined by
the BBER threshold per interface).
BBE – Background Block
Error
The number of errored blocks in an interval.
Integrity
A flag indicating that the data was valid. Note that the
Performance Monitoring data is not valid if not all the values
were stored (e.g., due to clock changes within the interval or
power up reset).
RADWIN 2000 User Manual
Release 2.5.40
9-11
The Monitor Log
Chapter 9
Table 9-3: Explanation of performance data
Data type
Additional Air Interface
PM Data
Additional Ethernet
Interface PM Data
TDM interface
Reported Value
Explanation
Max RSL
The maximum of the receive signal level (measured in dBm).
Min RSL
The minimum of the receive signal level (measured in dBm).
Max TSL
The maximum of the transmit signal level (measured in dBm).
Min TSL
The minimum of the transmit signal level (measured in dBm).
RSL Threshold 1
The number of seconds in which the Receive Signal Level (RSL)
was below the specified threshold.
RSL Threshold 2
The number of seconds in which the RSL was below the
specified threshold.
TSL Threshold
The number of seconds in which the Transmit Signal Level
(TSL) was above the specified threshold.
BBER Threshold
The number of seconds in which the Background Block Error
Ratio (BBER) exceeded the specified threshold.
Received Bytes
The number of Megabytes received at the specified port within
the interval
Transmitted Bytes
The number of Megabytes transmitted at the specified port
within the interval.
Throughput threshold
Seconds count when throughput fell below the threshold
Traffic threshold
Seconds count when actual traffic exceeded the threshold
Active seconds
The number of seconds that the configured TDM services are
active
Performance Monitoring Report Toolbar
You can use the toolbar to perform the actions described in the following table:
Table 9-4: Action of the toolbar buttons
Command Button
Action
Get Data
Gather current performance monitoring data.
Save
Save current performance monitoring data to a file
Clear
Clear current performance monitoring data
Thresholds
Set Thresholds
Selection Pane
Toggle on/off left panel
Close
Closes the Performance Monitoring window
Setting Air Interface Thresholds
Use the Thresholds button on the Monitoring Performance Report toolbar to set the Air
Interface Thresholds:
RADWIN 2000 User Manual
Release 2.5.40
9-12
Events, Alarms and Traps
Chapter 9
Figure 9-15: Threshold configuration dialog box
RSL Thresholds
Two RSL Thresholds can be defined. They are used as an indicator of problems in the radio
channel. You can check the RSS from the Link Budget Calculator results during installation.
Values of -5dB and -8dB from the current RSS are typical.
TSL Threshold
A counter is maintained, of the number of second intervals during which Tx power exceeds
this threshold.
BBER Threshold
The Background Block Error Ratio is measured as a percentage. The threshold can be set
from 0.1% up to 50%.
For links with Ethernet only service, 8% threshold is recommended. If there are no problems
during the interval, then for that threshold, the recommended BBER value should be 0. Since
the system provides a lossless Ethernet service, there is throughput degradation in case of
interference. The degradation is proportional to the BBER.
Ethernet Thresholds - Capacity
This is used as a basis for checking adherence to a Service Level Agreement. It is the number
of seconds count that the link capacity falls bellow the threshold.
Ethernet Thresholds - Traffic
The number of seconds count that received traffic exceeded this threshold. It can be used to
measure traffic peaks.
Events, Alarms and Traps
The Events Log
The Events Log records system failures, loss of synchronization, loss of signal, compatibility
problems and other fault conditions and events.
Note
The foregoing event types include events from all links for which this
managing computer has been defined as the traps address. Only events
from RADWIN equipment will be shown.
RADWIN 2000 User Manual
Release 2.5.40
9-13
The Events Log
Chapter 9
Alarms (traps) are displayed in the Events Log in the lower panel of the main window. The
Events Log may be saved as a text file.
The Events Log includes the following fields:
»
»
»
»
»
Sequential number (ID)
Date and time stamp
Message
Trap source
IP address of the ODU that initiated alarm.
For complete information about traps and alarms see Appendix E.
The events are displayed in the Events Log in the lower right-hand panel of the RADWIN
Manager main window:
Figure 9-16: Events Log Display
 To save the Events Log:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears
2. Click the Events Tab.
3. Select the file to save.
4. Click the check box to open the file for saving.
RADWIN 2000 User Manual
Release 2.5.40
9-14
RADWIN Manager Traps
Chapter 9
Click the
button and in the Select File dialog box indicate in which folder and under what
name the Events Log file is to be saved, and click OK.
Note
To store the Events Log, first define the IP address, subnet mask, default
gateway and trap destination address of the managing computer (see
page 8-7 for details).
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events, displayed in the
Events Log.
Table 9-5: RADWIN Manager Trap Messages
Trap Message
Severity
Remarks
Cannot bind to trap service port. Port 162 already in use by
ProcessName (pid: ProcessId)
Warning
RADWIN Manager will not catch any traps from the
ODU, some other application has grabbed this
port. For further detail see this web site.
Device unreachable!
Error
Check connectivity to ODU
Connected to 
Information
 Site will be reset.
Information
Restore Factory Default Settings in process on Site 
Information
Factory Settings: The process was not finished due to connection
issues.
Warning
Factory setting failed due to connectivity problem
to ODU
Reset: The process was not finished due to connection issues.
Warning
Factory setting failed due to connectivity problem
to target - ODU will not be reset
Cannot Write to Monitor file. There is not enough space on the disk.
Warning
Free some space on disk on the managing
computer and retry
Windows Error: . Cannot Write to Monitor file.
Warning
Operating System error on the managing computer
TDM Counters were cleared for both sides
Information
Identical IP addresses at  and

Warning
Set up a different IP to each site
The Product is not identified at the  site.
Warning
RADWIN Manager is incompatible with the ODU
software version
The Product is not identified at the  site.
Warning
The Product is not identified at both sites.
Warning
Product Not Identified!
Warning
The Manager identified a newer ODU release at the
 site.
Warning
ODU release is newer than RADWIN Manager
release.
Wizards are not available. RADWIN Manager will
be used just for monitoring. Upgrade the RADWIN
Manager. (You will get this message as a pop up)
The Manager identified a newer ODU release at both sites.
Warning
The Manager identified a newer ODU release at the
 site.
Warning
RADWIN 2000 User Manual
Release 2.5.40
9-15
Setting the Events Preferences
Chapter 9
Table 9-5: RADWIN Manager Trap Messages (Continued)
Trap Message
Severity
Remarks
Newer Version identified at the  site.
Warning
ODU release is newer than RADWIN Manager
release.
Wizards are not available. RADWIN Manager will
be used just for monitoring. Upgrade the RADWIN
Manager.
Newer Version identified at the  site.
Warning
Newer Version Identified!
Warning
Setting the Events Preferences
You can define a color for the messages to be displayed in the Event Log window, according
to the severity of the event. The severity is predefined.
 To set the Message color:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears.
2. Click the Events Tab:
Figure 9-17: Preferences dialog box - Event tab
3. Select the event type and click on the
button.
A color chart opens.
4. Select the required color.
5. Repeat for each of the event types.
 To set the message background color:
• Click Background Color to change the text background.
RADWIN 2000 User Manual
Release 2.5.40
9-16
Saving the Events Log
Chapter 9
 To reset the message colors:
• Click Reset Settings to return to the default color settings.
Saving the Events Log
You can save recorded events in an Events Log text file. New alarms are automatically added
to the text file, as they enter the Events Log.
Active Alarms
Upon setting a trap destination, applicable events are reported as active alarms to the user.
The active alarms are saved and can be viewed in the Active Alarms window.
 To view summary of saved alarms:
1. From the Tools menu, choose Active Alarm Summary.
2. Choose either of the sites offered.
The Active Alarms Summary window opens:
Figure 9-18: Active Alarms Summary
The active alarms display does not update itself until the Refresh button is used.
The following table provides an explanation of the command buttons.
Table 9-6: Active Alarms command buttons
Command
Action
Save
Saves the alarms in CSV or text format for further analysis
Refresh
Shows the active alarms at the moment of refresh
Site
Selects site for the active alarms
Close
Closes the active alarm window
RADWIN 2000 User Manual
Release 2.5.40
9-17
Viewing Recent Events
Chapter 9
Viewing Recent Events
Each ODU stores the last 256 events:
 To view the last 256 events:
1. Click Tools | Recent Events ... A window like the following is displayed:
Figure 9-19: Recent Events - Up to last 256 events at Site A
2. Use the Site button to choose Site B
3. Use the Save button to store the events in a tab-delimited list.
Reverting Alert Messages
Many alert messages in the RADWIN Manager have an option of the form “Do not show this
message again”. These alert messages can be reverted to their default state (shown) by
choosing the Advanced tab from the Preferences dialog:
Figure 9-20: Advanced Preferences
Just click the Restore Defaults button, followed by OK.
RADWIN 2000 User Manual
Release 2.5.40
9-18
Other Advanced Preferences
Chapter 9
Other Advanced Preferences
Enable and Disable Checking for Software Updates
If you are not on a network with Internet access, disable this.
Setting the RADWIN Manager Language
In the dialog of Figure 9-20, you can set the RADWIN Manager interface language, where
other localizations are available.
Setting SNMP Parameters
Use these choices to set the SNMP monitoring interval and time-out. These are only significant if you are using an SNMP based network management system such as RADWIN NMS.
Remote Power Fail Indication
Remote power fail indication indicates to one side that the other side has suffered a power
failure. The failed site sends a final trap indication about the power loss just before powering
off.
A “Dying-Gasp” circuit identifies the power failure at a minimum interval of 20 milliseconds
before the ODU or IDU powers off. During that interval a message notifying the power failure
is sent to opposite site. External alarm output number 4 indicates power failure at the opposite site.
Troubleshooting
Use the following table to troubleshoot LED fault indications:
Table 9-7: LED fault indicators
LED
Status
Remedy
PWR
Off
Check that power is connected to the IDU
IDU
Red
Check that the IDU/ODU cable is properly wired and connected.
ODU
Red
Check that the IDU/ODU cable is properly wired and connected.
Orange
Complete the installation procedure from the RADWIN Manager
Red
Check the antenna alignment. Check that the radio configuration of both site A and
site B units are the same (Channel and Link ID).
Orange
Alarm detected at the Site B interface or Local or Remote loopback
Red
Alarm detected at the Site A interface
Off
Ethernet only IDU or E1/T1 not configured
AIR I/F
SVC
RADWIN 2000 User Manual
Release 2.5.40
9-19
Replacing an ODU
Chapter 9
Table 9-7: LED fault indicators (Continued)
LED
Status
Remedy
Red
HSS not operational due to improper signal detection. This ODU is not transmitting
Orange
HSS is operational. One of the following conditions apply:
•
This ODU is a master that is generating signals and detecting signals
•
This ODU is a master that is generating signals but detected improper signals
HSS
•
This ODU is a client “Continue Tx” but is not detecting signals
•
This ODU is a client “Disable Tx” and is detecting signals from multiple
sources
All orange cases transmit.
STBY
Red
MHS mode Primary, Link state not active
Orange
MHS mode Secondary, Link state active
Use the following table to troubleshoot faults in the system:.
Table 9-8: System Troubleshooting
Symptom
No power
Remedy
Ensure that power is connected to the IDU
Ensure that the ODU cable is properly wired and connected
Complete the installation procedure from the RADWIN Manager
No signal
Weak signal
received
Check the antenna alignment. Check that the radio configuration of both site A and site B
units is the same (channel settings and Link ID)
Check the antenna alignment, reconfigure the link
Check the alignment tone sounds the Best Signal sequence
Replacing an ODU
Prior to any action ensure that both ODUs have the same software version. You can see this
on the inventory panels for each site.
For Site A, click Site A | Inventory and note the ODU software version. Repeat this for Site
B using Site B | Inventory.
If either ODU has an old software version, perform a software upgrade. It is important to configure the new ODU identically to the old ODU to avoid configuration mismatches, which will
disrupt the link.
An ODU may be reconfigured in several ways.
•
Use the backup configuration
If a backup of the configuration is available, restore that configuration using Site A|
Restore. Recall that backup files are linked to a MAC address. This won’t work for
an identical replacement ODU.
•
Manual configuration
The new ODU can be configured manually according to the link configuration.
Remember to use the same settings for Link ID, channels, link password, IP
addresses, and names.
RADWIN 2000 User Manual
Release 2.5.40
9-20
Restoring Factory Setup
Chapter 9
Restoring Factory Setup
 To restore factory setup:
• Use Site Configuration A or B, and then Operations | Restore Defaults. Always
restore the over-the-air site (B) first.
Online Help
Online help can be accessed from the Help menu on the main window of the RADWIN Manager.
Customer Support
Customer support for this product can be obtained from the local VAR, Integrator or distributor from whom it was purchased.
For further information, please contact the RADWIN distributor nearest to you or one of RADWIN's offices worldwide (see RADWIN Worldwide Offices at the beginning of this manual).
RADWIN 2000 User Manual
Release 2.5.40
9-21
RADWIN 2000
Broadband Wireless Transmission System
USER MANUAL
RELEASE 2.5.40
Part 2: Site Synchronization
UM 2000-2540/02.11
Chapter 10
Hub Site Synchronization
What is Hub Site Synchronization?
When several units are collocated at a common hub site, interference may occur from one
unit to another. RADWIN ODU units support the collocation of more than two units at a central site. Like any other RF deployment, the wireless operation is highly dependent on factors
such as available frequencies, the physical spacing between radios, other interfering radios,
and whether WinLink 1000 or RADWIN 2000 units are installed.
HSS does not eliminate the need for careful RF planning to ensure the
design will work as planned. See Chapter 2 of the User Manual (both
WinLink 1000 and RADWIN 2000) for information on installation site survey.
Note
For WinLink 1000 units, Hub Site Synchronization support depends on the
product model.
The RADWIN Hub Site Synchronization (HSS) method uses a cable connected from the master ODU to all collocated ODUs; this cable carries pulses sent to each ODU, which synchronize
their transmission with each other. The pulse synchronization ensures that transmission
occurs at the same time for all collocated units. This also results in all of the hub site units
receiving data at the same time, eliminating the possibility of interference that could result if
some units transmit while other units at the same location receive.
Figure 10-1 illustrates interference caused by non-synchronized collocated units.
RADWIN 2000 User Manual
Release 2.5.40
10-1
What is Hub Site Synchronization?
Chapter 10
Figure 10-1: Interference caused by collocated units
Adding HSS removes interference as shown in the next two figures:
Figure 10-2: Collocated units using Hub Site Synchronization (1)
Figure 10-3: Collocated units using Hub Site Synchronization (2)
The units are connected to each other with HSS cables and HSS Distribution Units.
One of the radios in the site is defined as HSS Master and generates synchronization pulses.
The other collocated radios in the site - the HSS Clients, are connected to the HSS Master and
synchronize their transmission to the pulses. An HSS Client can be configured to work in one
of two modes:
RADWIN 2000 User Manual
Release 2.5.40
10-2
Hardware Installation
Chapter 10
•
HSS Client-Continue Transmission (HSC-CT): If the unit loses synchronization
with the HSS Master, the link remains active. However, without synchronization pulses,
it is possible that this unit will cause interference.
•
HSS Client-Disable Transmission (HSC-DT): If the unit loses synchronization with
the HSS Master, the link is dropped until the synchronization pulses resume. This setting prevents the unit from causing interference.
The remote ODUs that are not located at the hub site, are called Independent Units.
Note
WinLink 1000 radios used as independent units do not require HSS
hardware.
Hardware Installation
Connecting an HSS Unit
A single HSS unit supports up to ten collocated ODUs. In addition to each unit being connected to its IDU or PoE device, the collocated unit has an additional cable that is connected
to the HSS Unit. The HSS Unit is a compact, weatherproof (IP67) connector box that is
installed on the same mast as the ODUs. All collocated units connect to this box using CAT-5e
cable. Cables in prepared lengths are available for purchase.
The HSS unit is supplied with ten protective covers; any port not in use must be closed with a
protective cover.
Figure 10-4: HSS Interconnection Unit
•
Note
•
For a single HSS unit, ensure that the collocated units are connected
in sequence from SYNC 1. If an ODU is removed from the hub site,
then all remaining ODUs must be reconnected to maintain the connectivity.
You may cascade (daisy-chain) two or more HSS Units with an HSS
cable. The method is described in detail below.
 To connect an ODU to an HSS unit:
1. Unscrew the protective cover from the port marked SYNC 1.
2. Connect the RJ-45 connector from one end of the prepared CAT-5e cable to SYNC 1.
3. Connect the other end of the CAT-5e cable to the ODU connector labeled SYNC.
RADWIN 2000 User Manual
Release 2.5.40
10-3
Using a Single HSS Unit
Chapter 10
4. Tighten the protective seal that is on the prepared cable over the RJ-45 connector.
5. Repeat for all ODUs that are to be collocated at the hub site. The next ODU to be
connected is inserted in SYNC 1, SYNC 2, followed by SYNC 3 and so on.
Using a Single HSS Unit
Figure 10-5: HSS Wiring schematic
The wiring, as shown in Figure 10-5 is self explanatory. The Sync signal path is less self evident. If we set ODU 1 (on SYNC 1) to HSS Master, then the Sync signal path is as shown in
Figure 10-6. The signal travels from ODU 1 to SYNC 1, from SYNC 1 to SYNC 2, from SYNC
2 to ODU 2 and back again. The back and forth paths repeat for the second to fourth ODU,
from left to right. The signal exits the HSS unit at SYNC 5 and terminates in ODU 5.
The choice of the ODU on SYNC 1 as HSS master is not mandatory, but is good practice. If for
example we were to use ODU 3 as HSS master, the Sync signal path would be ODU 3 to SYNC
3, then left and right to SYNC 2 and SYNC 4. It would then propagate to ODUs 2 and 4, terminating at both ODUs 1 and 5.
Figure 10-6: HSS sync signal path with ODU 1 as HSS Master
RADWIN 2000 User Manual
Release 2.5.40
10-4
Using More than One HSS Unit
Chapter 10
Using More than One HSS Unit
In a large collocation site, several HSS units may be cascaded (daisy-chained) subject to the
following conditions:
Condition 1: Cabling Sequence
1. Up to nine ODUs may be connected to the first HSS unit using HSS ports SYNC 1, SYNC 2,
SYNC 3,... up to SYNC 9 in order without leaving empty ports.
2. The next available SYNC port of the first HSS unit should be connected to SYNC 10
of the second HSS unit as shown in Figure 10-7. In the illustration, the next
available port on the first HSS unit is SYNC 6.
3. The second HSS unit may be filled out with up to nine more ODUs in reverse
order. That is, connect SYNC 9, SYNC 8, SYNC 7... as shown in Figure 10-7.
Figure 10-7: Cascading two HSS units
4. To add a a further HSS unit: Connect the next available SYNC port from the second
HSS unit in descending order (SYNC 5 in Figure 10-7) to SYNC 1 of the third
HSS unit.
5. ODUs are connected to the third HSS unit from SYNC 2 as shown in Figure 10-8,
in ascending order:
RADWIN 2000 User Manual
Release 2.5.40
10-5
HSS Error Notification
Chapter 10
Figure 10-8: Cascading three HSS units
6. If further ODUs are required, observe the convention that additional even
numbered units are populated in descending order from SYNC 9 and odd
numbered HSS units are populated in ascending order from SYNC 2.
Note
If an ODU is disconnected from an HSS unit, then all remaining ODUs must
be moved up or down to maintain the connectivity.
Condition 2: Total HSS Cable Length
The total path of the HSS sync pulse must not exceed 300m. This applies no matter how
many HSS units are used. To illustrate the method for calculating the sync pulse path length
we show three examples. For our purpose, let:
Lmn denote the length of the ODU-HSS unit cable at SYNC n on HSS unit m
Hm be the length of the cable joining HSS unit m to HSS unit m+1
One HSS unit with five collocated ODUs
PathLength = L 11 + 2  L 12 + 2  L 13 + 2  L 14 + L 15
Two cascaded HSS units as shown in Figure 10-7
PathLength = L 11 + 2  L 12 + 2  L 13 + 2  L 14 +
2  L 15 + H 1 + 2  L 29 + 2  L 28 + 2  L 27 + L 26
Three cascaded HSS units as shown in Figure 10-8
PathLength = L 11 + 2  L 12 + 2  L 13 + 2  L 14 +
2  L 15 + H 1 + 2  L 29 + 2  L 28 + 2  L 27 + 2  L 26 +
H 2 + 2  L 32 + 2  L 33 + 2  L 34 + L 35
HSS Error Notification
In the event of an HSS installation fault, the ODU will sound a beep pattern according to the
following chart, also printed on the ODU product label:
RADWIN 2000 User Manual
Release 2.5.40
10-6
ODU/HSS Unit Connection Pinout
Chapter 10
Figure 10-9: ODU beep for HSS Error
ODU/HSS Unit Connection Pinout
Table 10-1: ODU/HSS Unit Connection Pinout
Color
ODU
RJ-45
HSS UNIT
RJ-45
White/Green
Green
White/Orange
Not connected
Orange
Blue
White/Blue
White/Brown
Brown
Radio Frame Pattern (RFP)
A Radio Frame Pattern (RFP) is the cycle duration of transmit and receive of the air-frame.
Without HSS
When selecting TDM or Ethernet services, the system automatically and transparently
chooses the optimal RFP. When TDM and Ethernet services are configured, the RFP is optimized for TDM.
RFP and HSS
When HSS is used, the RFP for the collocated radios must be selected manually.
Both WinLink 1000 and RADWIN 2000 use the Time Division Duplex (TDD) mechanism.
Under HSS, TDD enables synchronization of transmission for the collocated units as shown in
Figure 10-10:
RADWIN 2000 User Manual
Release 2.5.40
10-7
RFP: General Radio Frame Pattern
Chapter 10
Figure 10-10: Radio Frame Pattern
Five RFP types (A to E) are available. Under HSS the RFP must be configured by the user
depending on the type of the radio products, services and channel bandwidth in accordance
with the Table 10-2 and Table 10-3.
The tables describe the efficiency of the air interface according to the RFP type, radio products mix, services and channel bandwidth. The tables may also be viewed in the RADWIN
Manager and in the Link Budget Calculator for both WinLink 1000 and RADWIN 2000. The
efficiency of the air interface will vary according to the product used.
Table 10-2: Radio Frame Pattern Table - RADWIN 2000
RFP
40 MHz
20 MHz
10 MHz
5 MHz
TDM
Available
Ethernet
Available
TDM
Available
Ethernet
Available
TDM
Available
Ethernet
Available
TDM
Best fit
Ethernet
Best fit
Best fit
Best fit
Best fit
Best fit
Best fit
Best fit
Available
Available
Table 10-3: Radio Frame Pattern Table - WinLink 1000
RPF
20 MHz
TDM
Best fit
Ethernet
Best fit
N/A
N/A
10 MHz
TDM
Available
Ethernet
Available
N/A
Best fit
N/A
N/A
N/A
N/A
Available
Available
5 MHz
TDM
N/A
Ethernet
N/A
Available
Best fit
Available
Best fit
N/A
Available
N/A
N/A
N/A
Best fit
Available
Available
N/A
N/A
Legend:
Best fit - optimal RFP choice for TDM and Ethernet services.
Available - available RFP for TDM and Ethernet services, but not optimal.
N/A - service unavailable
Select the RFP that gives you the Best Fit or Available for required system services and
select the channel bandwidth accordingly.
The RFP must be the same for each link within the collocated system.
Note
RFP: General Radio Frame Pattern
When setting the RPF, the following considerations should be borne in mind:
•
When synchronizing RADWIN 2000 units you must use RFP B or E
RADWIN 2000 User Manual
Release 2.5.40
10-8
RFP: RADWIN 2000 Considerations
Chapter 10
•
If you mix RADWIN 2000 and WinLink 1000 units in a collocated site, you must use
RFP B or E
•
Selection of the RFP influences the capacity, latency and TDM quality
•
RFP influences capacity and latency. Jitter buffer configuration can be used to set the
TDM quality (see the User Manual, Chapter 5, TDM Services selection)
•
Using the Link Budget Calculator, you can see the affect of the RFP on the Ethernet
throughput.
RFP: RADWIN 2000 Considerations
•
The performance of RADWIN 2000 radios that operate with RFPs B or E can be seen
in the Link Budget Calculator.
•
For RADWIN 2000 C series: If the HSS Master works in asymmetric Tx/Rx ratio, then
all other collocated RADWIN 2000 units must operate in the same Tx/Rx ratio. In this
case the ratio will be fixed and not automatic-adaptive.
•
Installation/Configuration considerations: If you are using RADWIN 2000 C master
and RADWIN 2000 clients, the Services and Rates dialog will look like this:
Figure 10-11: Services and Rates - RADWIN 2000 C master, RADWIN 2000 clients
•
The circled areas should not be used. Using those areas, you may loose the collocated
link with the longest distance between sites. If you do move the slider into a circled
area, you will receive a popup warning:
RADWIN 2000 User Manual
Release 2.5.40
10-9
RFP: RADWIN 2000 Considerations
Chapter 10
Figure 10-12: Services and Rates - RADWIN 2000 C master, RADWIN 2000 clients - Extreme
asymmetric allocation
By restricting one direction into the restricted area, the more distant sites may not
even be able to sustain the link much less send or receive data.
•
Asymmetric Allocation and Collocation: If the link is collocated, the use of Asymmetric
Allocation is limited.
The effective available range for Asymmetric Allocation (between the two circled tick
in Figure 10-11) is primarily determined by three factors:
•
The RFP in use (B or E)
•
Channel Bandwidth
•
Link distance
The first two parameters are entered during Link
Installation/Configuration.
•
Possible scenarios are shown in Table 10-4.Whenever Asymmetric Allocation is available, it is static for all traffic conditions.
RADWIN 2000 User Manual
Release 2.5.40
10-10
RFP: WinLink 1000 Considerations
Chapter 10
Table 10-4: Asymmetric Allocation with Collocated Links - Scenarios
HSS Master
HSS Client
Scenario: If you try to... Result
Link down
WinLink 1000
RADWIN 2000
RADWIN 2000
Remarks
Change master to
asymmetric allocation
•
Releases prior to
2.4 - Link down
•
Release 2.4 later
(RADWIN 2000 PDH
and RADWIN 2000
L series) - Link
down
•
Release 2.4 and
later (RADWIN
2000 C and RADWIN 2000 Xseries) TDM services
stopped, link set to
transmission ratio
of master
Reversion to 50/50 restores link
Release 2.4 and later (RADWIN
2000 C and RADWIN 2000
Xseries) - Asymmetric Allocation
slider visible but cannot be
changed
WinLink 1000
RADWIN 2000
RADWIN 2000
Change client to
asymmetric
Asymmetric Allocation slider
not displayed
You cannot do this
Change client to
asymmetric
Asymmetric Allocation slider
not displayed
You cannot do this
WinLink 1000
WinLink 1000
RADWIN 2000
RFP: WinLink 1000 Considerations
•
When WinLink 1000 radios are collocated with RADWIN 2000 radios using HSS, all
radios must use RFP B or E.
•
The performance of WinLink 1000 radios that operate with these RFPs can be seen in
the Link Budget Calculator.
•
The choice of the unit to be the HSS master is a matter of convenience. There is no
technical reason to prefer a WinLink 1000 over a RADWIN 2000 as HSS master or vice
versa. It is however, recommended that you use the RADWIN 2000 as master, since it
will enforce the correct RFP on the other collocated units.
The following list summarizes the effect of using RFP B or E on WinLink 1000 radios. These
effects should be taken into consideration when planning new installations:
•
Channel bandwidth 5 MHz is available under RFP E but is only supported for WinLink
Access products
•
For products supporting a maximum throughput of 18.1 Mbps, the maximum Ethernet
throughput is 14.5 Mbps at 20 MHz channel bandwidth and 9.3 Mbps at 10 MHz channel bandwidth
•
For products supporting maximum throughput of 22.5 Mbps, the maximum Ethernet
throughput is 21.4 Mbps at the 20 MHz channel and 9.3 Mbps at 10 MHz channel
bandwidth
RADWIN 2000 User Manual
Release 2.5.40
10-11
HSS Status LED on the IDU-C and New Style IDU-E
Chapter 10
HSS Status LED on the IDU-C and New Style IDU-E
The IDU-C and IDU-E have a front panel HSS status LED:
Table 10-5: IDU-C and New Style IDU-E Front Panel LEDs for HSS
Color
Function
Green
This ODU is HSS master, generating signal, and HSS Sync is OK
Blinking
Green
This ODU is a HSS client and in Sync
Red
HSS not operational due to improper signal detection. This ODU is not transmitting
HSS is operational. One of the following conditions apply:
Orange
•
This ODU is a master that is generating signals and detecting signals
•
This ODU is a master that is generating signals but detected improper signals
•
This ODU is a client “Continue Tx” but is not detecting signals
•
This ODU is a client “Disable Tx” and is detecting signals from multiple sources
All orange cases transmit.
HSS is not activated
Off
HSS is not supported (WinLink 1000 only)
Disconnection between ODU and IDU
Link Configuration and HSS
For WinLink 1000 HSS-enabled units and all RADWIN 2000 units, the Hub Site Synchronization Settings dialog box appears in both the Link Installation and Configuration Wizards.
Figure 10-13: HSS Settings: Left - WinLink 1000 client, Right - RADWIN 2000 master
The Synchronization Status dialog box displays the current status of each side of the link.
•
Operation: Type of unit
•
Hub Sync Master (HSM)
•
Hub Sync Client - Disable Transmission (HSC-DT)
RADWIN 2000 User Manual
Release 2.5.40
10-12
Link Configuration and HSS
•
Hub Sync Client - Continue Transmission (HSC-CT)
Continue Transmission is intended to work if there is no HSM pulse. If a
wrong HSM pulse is detected, a WinLink 1000 will resync, adapting to the
HSM RFP and continue whereas RADWIN 2000 may stop.
Note
•
•
•
Chapter 10
Independent Unit
Synchronization:
•
N/A- for Master or Independent Units
•
Synchronized - for Hub Site Clients
•
Not Synchronized - for Hub Site Clients
External Pulses:
Table 10-6: External Pulse Status
HSS Sync Status
Meaning
Color code
Generating
ODU is HSM and generates the
sync pulse
Detected
ODU is HSC and detects the
sync pulse
Not detected
ODU is independent
Generating and detected
HSM, but other HSM present
Generating and
Improperly Detected
RADWIN 2000 ODU is HSM,
but but detects a WinLink 1000
HSM signal that is not RFP E
Not detected
HSC but no HSM present
Improperly detected
HSC but HSM pulse doesn’t fit
the HSC as configured. Occurs
only for RADWIN 2000, which
stops transmitting.
Green
Orange
Red
 To configure the Operational States of the Hub Site unit
1. Click the Enabled check box
2. Click the Configure button
The Hub Site Configuration dialog box with the current status of the ODUs is displayed.
3. Select the type of unit configuration from the drop-down list.
4. Select the appropriate RFP radio button. Some RFP options may be disabled depending on the bandwidth previously selected.
Note
Take care to avoid incorrect configuration of bandwidth, RFP or to set
multiple Hub Sync Masters, as system interference can occur. RADWIN
Manager provides error messages and tool tips if the system is configured
with mismatches.
RADWIN 2000 User Manual
Release 2.5.40
10-13
Site Configuration and HSS
Chapter 10
Figure 10-14: Hub Site Configuration dialog - Left WinLink 1000, right RADWIN 2000
Site Configuration and HSS
For units that support HSS, the Hub Site Sync option appears in the Air Interface section and
displays the current HSS of the unit. Configure the unit from the Link Configuration Wizard
according to the procedure described above.
Figure 10-15: Site Configuration: HSS - Left - WinLink 1000 client, Right - RADWIN 2000 master
For WinLink 1000 units without HSS support, Figure 10-16 is displayed instead of
Figure 10-15:
RADWIN 2000 User Manual
Release 2.5.40
10-14
Site Configuration and HSS
Chapter 10
Figure 10-16: HSS Not Supported
RADWIN 2000 User Manual
Release 2.5.40
10-15
Chapter 11
Using the RADWIN GSU
What is it for
The GPS-based synchronization unit (GSU) is designed to handle inter-site interferences
under large-scale deployment scenarios.
The GSU is an outdoor unit consisting of a standard WinLink 1000 enclosure, a GPS antenna
and a PoE device.
The GSU is connected to the HSS Unit using a standard HSS cable. It synchronizes the transmission timing of multiple Hub-Sites to the same clock source thus eliminating mutual interference.
GSU Functionality
The GSU receives a synchronization signal from the GPS once per second. It distributes a
RADWIN proprietary synchronization signal to all other ODU units using the RS422 protocol
and the standard HSS mechanism, where the GSU acts as an HSM unit.
When the GSU doesn’t receive a synchronization signal from the GPS for 30 seconds, it moves
automatically to Self-Generation mode and acts as a regular HSM unit, until the GPS recovers.
Typical GSU Scenarios
Independent Distributed Sites
In the scenario of Figure 11-1, we have multiple independent collocated sites, which may
interfere with each other. To meet this situation, we coordinate all of them using the GSU as
shown.
The GSU functions like “wide area HSS unit”, ensuring that all participating radios at the locations marked GSU each transmit and receive at the same time.
RADWIN 2000 User Manual
Release 2.5.40
11-1
Multiple Distributed Sites with Communication
pendent dis
Chapter 11
tributed sites
Figure 11-1: GSU Scenario - Independent distributed sites
Multiple Distributed Sites with Communication
What happens if, in Figure 11-1, the GSU towers themselves have radios communicating as
shown in Figure 11-2?
Consider GSU 1 and GSU 2: Both collocated towers transmit and receive simultaneously. However, the radios communicating at GSU 1 and GSU 2 must transmit and receive in turn according to the scheme in marked “Normal Phase” in Figure 11-3. This is an impossible situation,
if all the links must send and receive together. It is further complicated by adding a third and
further sites as shown.
Figure 11-2: GSU Scenario - Communicating distributed sites
RADWIN 2000 User Manual
Release 2.5.40
11-2
Cascaded Sites using Shifted Phase Transmission
Chapter 11
Cascaded Sites using Shifted Phase Transmission
The solution offered here is not a “universal cure”. The following conditions are necessary, but
in any specific case may not be sufficient:
•
The GSU sites (marked 1, and 3 above) are sufficiently far apart as to ensure that
there is no mutual interference between communicating sites (1-2 and 2-3 above)
•
There should be no interference between non-communicating sites (1 and 3 above).
To see how it works, we use Figure 11-2. The GSU towers are numbered and marked for
cascading, 1-2 and 2-3. There should not be a link between 1 and 3.
The GSU can synchronize the TDD timing of several sites enabling the cascading of consecutive links without mutual interference.
To use cascading, the TDD timing of the even-ordered links (GSU 2 above) must be “shifted”
(Shifted Phase) and odd-ordered links (GSU 1 and GSU 3 above) must be “unshifted” (Normal
Phase). The phase shift is half of the Radio Frame Duration (RFD) from the chosen RFP. The
scheme is shown in Figure 11-3.
Since the GSU is always HSS master (HSM), at each GSU location, the GSU can “force” the
synchronization of its collocated radios. By half RFD shifting, alternate collocated sites can
talk to each other.
Figure 11-3: Phase shifted transmission - phase shift is 1/2 the RFD
Choice of normal or shifted phase is configurable per GSU using the RADWIN Manager.
GSU Redundancy
The GSU is designed to support redundancy, improving the robustness of a GSU based topology.
In redundancy mode, two GSUs are installed at the same HSS site. One of them self-configures to generate HSS sync signals. We will call it the Primary unit. The other one, the Secondary unit remains dormant merely polling the first GSU. If the Primary GSU fails, then the
Secondary GSU becomes active immediately. If the Primary unit becomes active again, it
remains dormant, reversing the original roles. The choice of the Primary GSU is random and
of no significance.
If the Primary GSU fails, and then the Secondary GSU also fails to receive sync signals from
its GPS, then it moves to self-generation HSM mode like an ordinary HSM ODU until its GPS
recovers.
RADWIN 2000 User Manual
Release 2.5.40
11-3
GSU Kit Contents
Chapter 11
Figure 11-4: Make the GSUs the first two collocated units
Redundancy switching is completely transparent to the GSU-managed links.
GSU Kit Contents
The GSU package includes:
•
1 x GSU
•
1 x Mounting Kit
•
1 x GPS Antenna
•
1 x GPS Antenna Mounting Kit
•
1 x RF Cable, 1.5m
•
CD
GSU Installation
Overview
The GSU uses the same container and cabling as a WinLink 1000 unit.
RADWIN 2000 User Manual
Release 2.5.40
11-4
Preparing the GSU for Use
Chapter 11
Figure 11-5: General GSU configuration
In that respect, all of the considerations of Chapter 3, Chapter 17 and Chapter 18 of the
use Manual apply to the GSU.
It may be configured using the regular RADWIN Manager or Telnet.
Preparing the GSU for Use
Use the method of Chapter 19, Preloading an ODU with an IP Address to change the IP
address from the default (10.0.0.120). In the example screen captures below, we use
192.168.222.20 with Subnet Mask 255.255.252.0.
Mounting the GSU
Mount the GSU and antenna. Ensure that its ODU port connected to its PoE device and the
HSS cable is connected to the HSS unit as shown. The external LAN port of the PoE device is
connected to the managing computer. If you are accessing the GSU through a network it is
essential that you use the IP preloading method. The default IP address may be inaccessible
and you may not use the Local Connection method over a network.
Configuring the GSU
Getting Started
To configure the GSU, you log on to it, exactly as in Chapter 4.
The GSU Main Window
Here is the main window for GSU configuration:
RADWIN 2000 User Manual
Release 2.5.40
11-5
Configuring the GSU
Chapter 11
Figure 11-6: GSU Main widow at startup
The top five items in the GSU Monitor panel are taken from a satellite. The transmission
Phase may be Normal as shown or Shifted. It purpose, together with the Tx Ratio bar, will
be explained below.
The Status Box
Under normal operating conditions, it will be green as shown, indicating that it is synchronized with a satellite.
If satellite synchronization is lost, then the GSU will function as an independent HSM and the
status box will change color:
The Main Menu
The main menu is a subset of the main menu applicable to the WinLink 1000. Notice that
there are no Installation or Configuration wizards. Such configuration as is necessary is carried out using a modified version of Site Configuration for WinLink 1000.
Similarly, the Tool bar is a subset of that applicable to the WinLink 1000.
RADWIN 2000 User Manual
Release 2.5.40
11-6
Configuring the GSU
Chapter 11
Using Site Configuration for the GSU
Site Configuration: System
Here is the opening window for Site Configuration:
Figure 11-7: Site Configuration: System
It is similar to that of the WinLink 1000.
RADWIN 2000 User Manual
Release 2.5.40
11-7
Configuring the GSU
Chapter 11
Site Configuration: GPS Sync Unit
This window is the main GSU configuration tool:
Figure 11-8: Site Configuration: GPS Sync Unit
Note
The 1000 and 2000 labels refer to WinLink 1000 and RADWIN 2000 radios,
respectively. The actual annotation seen may vary, but the intention should
be clear.
1. Setting the RFP for HSS
The GSU is automatically configured as HSS Master (HSM).
Ensure that no other collocated ODU is configured as HSM.
Note
If the hub site consists only of WinLink 1000 units, then any suitable RFP may be chosen.
If there are one or more RADWIN 2000 units, you must use RFP B or E.
The permitted RFPs are also dependent on channel bandwidth and are color coded as follows:
You May use RFP/
Channel
Bandwidth
combinations with
this color
For these collocated radios
WinLink 1000 only
RADWIN 2000 only
WinLink 1000 and RADWIN 2000 together
None - unavailable
RADWIN 2000 User Manual
Release 2.5.40
11-8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 200
PDF Version                     : 1.7
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:e3424d29-18ad-4d71-88d0-cb890a31990d
Modify Date                     : 2011:03:09 17:35:04-08:00
Create Date                     : 2011:03:09 17:34:38-08:00
Metadata Date                   : 2011:03:09 17:35:04-08:00
Document ID                     : uuid:8a56138f-dc18-467b-b694-b35c49c43119
Format                          : application/pdf
Title                           : STW
Creator                         : FrameMaker 8.0
Author                          : DAF
Subject                         : 1.790 User Manual
Producer                        : Acrobat Distiller 10.0.1 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3KRW2025

Navigation menu