Raven E1003925 Remote Control Transmitter User Manual 99300799 pmd

Raven Industries Remote Control Transmitter 99300799 pmd

User Manual

Download: Raven E1003925 Remote Control Transmitter User Manual 99300799 pmd
Mirror Download [FCC.gov]Raven E1003925 Remote Control Transmitter User Manual 99300799 pmd
Document ID679123
Application IDo0dNDNHtIb0A5rDtsX3JXQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.98kB (124771 bits)
Date Submitted2006-07-10 00:00:00
Date Available2006-07-10 00:00:00
Creation Date2006-07-05 13:15:42
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2006-07-10 15:07:34
Document Title99300799.pmd
Document CreatorPageMaker 7.0
Document Author: abumls1

OPERATION GUIDE
TRANSMISSION
INDICATOR LIGHT
HEAD UP/DOWN BUTTON
Press and hold to raise or
lower the head section.
PROGRAM SET BUTTON
Press to capture any position
of the bed as a programmed
position (3 unique positions).
Press the recall buttons (“P1,
P2 or P3”) to return bed to
any of the preset positions.
To Program Preset Positions:
1. Set the head and/or foot to
the desired position.
2. Press the program set button
once.
3. Press position recall button
“P1” to save position.
4. Repeat steps 1 thru 3 above
to program favorite positions
for “P2” and “P3”.
HEAD MASSAGE BUTTON
Press the “+” symbol to activate the
head massager at a preset intensity.
Press and hold the “+” symbol to
intensify head massager. Press and
hold the “–” symbol to decrease head
massager intensity.
STOP BUTTON
Press to immediately stop
all active bed functions.
FLAT BUTTON
Press to return bed
to the level position.
FOOT UP/DOWN BUTTON
Press and hold to raise or
lower the foot section.
POSITION RECALL BUTTONS
Press to activate a position set
by the program button.
FOOT MASSAGE BUTTON
Press the “+” symbol to
activate the foot massager at
a preset intensity. Press and
hold the “+” symbol to
intensify foot massager. Press
and hold the “–” symbol to
decrease foot massager
intensity.
NEUROSAGE ON/OFF BUTTON
Press to activate or deactivate
the Neurosage wave vibration
system.
NEUROSAGE WAVE INTENSITY BUTTON
Press and hold the “+” symbol to intensify
Neurosage wave intensity. Press and hold
the “–” symbol to decrease Neurosage
wave intensity.
MASSAGE NOTE:
When activated, the massage system will launch the prior intensity setting used and automatically
shut off after 30 minutes. To restart Neurosage wave, press the Neurosage on/off button. To restart
head or foot massagers, press the “+” symbol on the head or foot massage button/s.
IMPORTANT:
Read advisory information in the owners manual carefully before using this product. The
potential for electrical shock exists if electrical components are not installed or operated
properly.
See back of page for additional programming features...
EDR10488 4/05
Document Part No. 99300799
www.lpadjustablebeds.com
© Leggett & Platt, Inc.
4002 PROGRAMMING
To set channels on a single base:
1. Plug the bed into a power
source and within 30 seconds,
press the head up button on
the hand control until the
transmission indicator light
illuminates. This will confirm
that the hand control and the
bed are communicating.
2. The hand control channel is
now programmed.
To set channels for 2 or more
beds to operate independently:
1. Unplug all beds from their
power sources.
4002 BATTERY REPLACEMENT
Requires (2) CR2032 3 volt batteries.
REMOVAL:
1. Remove the battery
compartment cover
located on the back of
the hand control
(FIGURE 1).
2. Press the roundshaped tab (FIGURE 2)
and each battery will
eject from the plastic
captive clip (FIGURE 3).
3. Grasp and remove
batteries. Note
position of batteries
when removing for
replacement.
2. Plug in the first bed to be
programmed and within 30
seconds, press the head up
button on the hand control until
the transmission indicator light
illuminates. This will confirm
that the hand control and the
bed are communicating.
3. Repeat steps 1 and 2 with each
base requiring programming (It
is important to use the specific
hand control that will be used
to operate the bed). Beds prior
programmed with the remote
need not be unplugged.
FIGURE 2
BATTERIES
FIGURE 1
REPLACEMENT:
4. Position the new
batteries face-up
and insert into the
plastic captive clips
(reverse of removal).
5. Carefully push
batteries in and
down to install.
PUSH DOWN
ON TAB TO
EJECT BATTERIES
4. Multiple beds are now
programmed for independent
operation.
Note: In the event of power
failure or if bed is inadvertently
unplugged from the electrical
power source, wait 30 seconds
(after power is restored) before
using any hand control. This
will prevent bases from
learning and working
simultaneously.
PUSH IN (SLIGHTLY)
AND SLIDE OFF
BATTERY
COMPARTMENT
COVER
6. Replace battery
compartment cover.
WHEN BATTERY EJECTS
FROM CAPTIVE CLIP,
ROTATE UP AND OUT
OF BATTERY
COMPARTMENT
TO REMOVE
FIGURE 3
Re:
Certification for Raven Transmitter
Model(s): E1003925
FCC ID: KSME1003925
IC: 2004A-E1003925
USER'S MANUAL INFORMATION
(PRELIMINARY)
The User's Manual is in preparation. The following material will also be contained in the
manual:
WARNING: Changes or modifications not expressively approved by the party
responsible for compliance could void the user's authority to operate the equipment.
The term “IC:” before the radio certification number only signifies that Industry Canada
technical specifications were met.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:bc9b15bf-bbb2-4854-9f32-0e0c8d8a586e
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PageMaker 7.0
Modify Date                     : 2006:07:10 15:07:34-04:00
Create Date                     : 2006:07:05 13:15:42-04:00
Metadata Date                   : 2006:07:10 15:07:34-04:00
Document ID                     : uuid:7bb2b5ea-75b1-4bbf-a0b7-9d2b6f2f2cae
Format                          : application/pdf
Title                           : 99300799.pmd
Creator                         : abumls1
Author                          : abumls1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KSME1003925

Navigation menu