Raycan Technology RADWALL Area radiation monitor User Manual RadWall H User Guide FCC

Raycan Technology Co.,Ltd.(Su Zhou) Area radiation monitor RadWall H User Guide FCC

User Manual

Download: Raycan Technology RADWALL Area radiation monitor User Manual RadWall H User Guide FCC
Mirror Download [FCC.gov]Raycan Technology RADWALL Area radiation monitor User Manual RadWall H User Guide FCC
Document ID3705657
Application IDjH9qL2Ki3vnJbt+3xNBmeQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.17kB (214686 bits)
Date Submitted2018-01-09 00:00:00
Date Available2018-01-09 00:00:00
Creation Date2017-12-25 16:10:45
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2017-12-25 16:10:45
Document TitleRadWall-H User Guide-FCC
Document CreatorAdobe Illustrator CS6 (Windows)

PACKAGE CONTENTS
ITEM
QTY
RadWall-H
Mounting plate
Flat-head screw (M4 x 14 mm)
User guide
Power adapter
MicroUSB cable
TROUBLESHOOTING
§ 15.19 Labelling requirements.
try to correct the interference by one or more of
This device complies with part 15 of the FCC
the following measures:
Rules. Operation is subject to the following two
-Reorient or relocate the receiving antenna.
conditions: (1) This device may not cause harmful
-Increase the separation between the
interference, and (2) this device must accept any
equipment and receiver.
interference received, including interference that
-Connect the equipment into an outlet on a
may cause undesired operation.
circuit different from that to which the receiver
Area Radiation Monitor
is connected.
§ 15.21 Information to user.
-Consult the dealer or an experienced radio/TV
Any Changes or modifications not expressly
technician for help.
approved by the party responsible for compliance
could void the user's authority to operate the
PROBLEM
SOLUTION
equipment.
Unable to boot
Ensure power
adapter is plugged in
§ 15.105 Information to the user.
Continuous alarm
ringing
Confirm proximity
to radiation source;
check alarm
threshold settings
Note: This equipment has been tested and found
Alarm not ringing
near radiation source
Check alarm
threshold settings
These limits are designed to provide reasonable
* If your problem cannot be resolved, please
contact X-Z LAB or your account administrator.
RadWall-H
to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
*RF warning for Mobile device:
This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled
environment. This equipment should be
installed and operated with minimum distance
20cm between the radiator & your body.
protection against harmful interference in a
residential installation. This equipment generates
uses and can radiate radio frequency energy and,
if not installed and used in accordance with the
instructions, may cause harmful interference to
X-Z LAB, Inc.
2440 Camino Ramon
Suite #264
San Ramon, CA 94583
Phone
Email
(925) 359-6908
contact@x-zlab.com
radio communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to
USER GUIDE
RADWALL-H
Cable routing is included on the back of RadWall-H.
The power cord can be tucked into the groove
for better cable management.
AREA RADIATION MONITOR
POWER
S WITCH
RadWall-H is a next-generation, all-digital
area radiation monitor that combines three
functions in one:
TOP
• Alarm and display unit
• Built-in scintillation detector
• Self-healing and self-forming
mesh network capable monitor
RadWall-H has high detection accuracy,
high sensitivity, fast response, and a highresolution display, as well as other significant
advantages. RadWall-H can be used as a
standalone area radiation monitor, or multiple
units can be combined to form a protected
mesh network communicating via ZigBee.
RadWall-H also includes the RadSys 2.0
software to accommodate applications of
any size or complexity.
PRODUCT DIAGRAM
DISPLAY
MICRO USB
F IRMWARE
UPDATE PORT
POWER
J ACK
BOTTOM
OPERATING INSTRUCTIONS
Working Status
The device can issue overload indication, error
warnings, and audible and visible alarms. When the
absorbed dose rate exceeds the alarm threshold,
red lights and sound will indicate danger.
Startup/Installation
Plug RadWall-H into a standard power outlet. Turn
on power switch. TheRAYCANlogo is followed
by device ID, indicating active monitoring state.
Threshold Settings
The manufacturer default alarm threshold value
is 1 mrad/h (10 µGy/h). The alarm threshold range
can be set remotely via RadSys. Please check
the RadSys software manual for more details.
TECHNICAL SPECIFICATIONS
FEATURE
PARAMETER
Detector
YSO scintillator + SiPM
Type of Radiation
Detected
Gamma; X-ray
Energy Range
20 keV–30 MeV
Dose Rate Range
1 µrad/h–1 rad/h
(0.01 µGy/h–10 mGy/h)
Sensitivity
410 cps/mrad/h
(41 cps/uGy/h)
Energy
Response
≤ ±15% (∝ Cs-137)
Dose Rate
Linearity
≤ ±10% up to 1 rad/h
(10 mGy/h)
Accuracy
±10% (∝ Cs-137)
Alarm Threshold
User-set values for
dose rate:
100 µrad/h–1 rad/h
(1 µGy/h–10 mGy/h)
Alert Options
Audible (80 dB at 12 in /
30 cm); visual (display)
Alarm Response
Time
<2s
Overload Display
Activation when >
1 rad/h (10 mGy/h)
Overload indication up
to 10 rad (100 mGy/h)
Display Units
Gy; rad; cps
Dimensions
⌀ 6.89 x 1.97 in
(⌀ 175 x 50 mm)
Weight
19.0 oz (540 g)
Operating
Temperature
41–122 °F (5–50 °C)
Relative Humidity
≤ 90% (non-condensing)
EMI/EMC
Exceeds IEC 61526
FCC Compliance
FCC Part 15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2017:12:25 16:10:45+09:00
Metadata Date                   : 2017:12:25 16:10:45+08:00
Modify Date                     : 2017:12:25 16:10:45+08:00
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Thumbnail Width                 : 256
Thumbnail Height                : 188
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 14510 bytes, use -b option to extract)
Instance ID                     : uuid:06d43396-0e9a-43c2-867c-1a9d147cb036
Original Document ID            : xmp.did:e48aa1b1-c57c-684d-afe7-3a6339c65c24
Document ID                     : xmp.did:1F7D07044BE9E7119FC9EC37BB6BCC85
Rendition Class                 : proof:pdf
History Action                  : converted, saved, saved
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows), Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /, /
History When                    : 2017:04:06 19:08:08-07:00, 2017:12:25 16:10:25+08:00, 2017:12:25 16:10:39+08:00
History Instance ID             : xmp.iid:1E7D07044BE9E7119FC9EC37BB6BCC85, xmp.iid:1F7D07044BE9E7119FC9EC37BB6BCC85
Derived From Instance ID        : xmp.iid:1E7D07044BE9E7119FC9EC37BB6BCC85
Derived From Document ID        : xmp.did:1E7D07044BE9E7119FC9EC37BB6BCC85
Derived From Original Document ID: xmp.did:e48aa1b1-c57c-684d-afe7-3a6339c65c24
Derived From Rendition Class    : proof:pdf
Format                          : application/pdf
Title                           : RadWall-H User Guide-FCC
Producer                        : Adobe PDF library 10.01
Trapped                         : False
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : False
Max Page Size W                 : 279.999963
Max Page Size H                 : 147.999924
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, SegoeUISymbol, Industry-BoldItalic, Industry-BookItalic, Industry-Bold, Industry-Book, ProximaSoft-Light-SC700
Font Family                     : Arial, Segoe UI Symbol, Industry BoldItalic, Industry BookItalic, Industry Bold, Industry Book, ProximaSoft Light-SC700
Font Face                       : Regular, Regular, BoldItalic, BookItalic, Bold, Book, Light-SC700
Font Type                       : Open Type, Open Type, Unknown, Unknown, Unknown, Unknown, Unknown
Font Version                    : Version 5.10, Version 5.01, Version 5.010;PS 5.005;hotconv 1.0.57;makeotf.lib2.0.21895, Version 5.010;PS 5.005;hotconv 1.0.57;makeotf.lib2.0.21895, Version 5.010;PS 5.005;hotconv 1.0.57;makeotf.lib2.0.21895, Version 5.010;PS 5.005;hotconv 1.0.57;makeotf.lib2.0.21895, Version 5.010;PS 5.005;hotconv 1.0.57;makeotf.lib2.0.21895
Font Composite                  : False, False, False, False, False, False, False
Font File Name                  : arial.ttf, seguisym.ttf, AdobeHeitiStd-Regular.otf, AdobeHeitiStd-Regular.otf, AdobeHeitiStd-Regular.otf, AdobeHeitiStd-Regular.otf, AdobeHeitiStd-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : 默认色板组
Swatch Group Type               : 0
Page Count                      : 2
Creator                         : Adobe Illustrator CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALQQ-RADWALL

Navigation menu