Raytheon IDS M3-VHF-136 110W VHF BASE STATION User Manual USERS MANUAL MM102558V1R1A
JPS COMMUNICATIONS, INC. 110W VHF BASE STATION USERS MANUAL MM102558V1R1A
Contents
USERS MANUAL MM102558V1R1A
Overview Manual MM102558V1 R1A, Jul/06 MASTR® III Conventional ADC & P25 Conventional Base Stations MM102558V1 R1A MANUAL REVISION HISTORY REV DATE R1A Jul/06 REASON FOR CHANGE Initial Release. M/A-COM Technical Publications would particularly appreciate feedback on any errors found in this document and suggestions on how the document could be improved. Submit your comments and suggestions to: Wireless Systems Business Unit M/A-COM, Inc. Technical Publications 221 Jefferson Ridge Parkway Lynchburg, VA 24501 or fax your comments to: (434) 455-6851 or e-mail us at: techpubs@tycoelectronics.com ACKNOWLEDGEMENTS This manual covers M/A-COM products manufactured and sold by M/A-COM, Inc. This device made under license under one or more of the following US patents: 4,590,473; 4,636,791; 5,148,482; 5,185,796; 5,271,017; 5,377,229. The voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights, and trade secrets of Digital Voice Systems, Inc. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any way convert the Object Code into human-readable form. CREDITS MASTR and Voice Guard are registered trademarks of M/A-COM, Inc. GETC, ProVoice and Secur-It are trademarks of M/A-COM, Inc. Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation Pentium is a registered trademark of Intel Corporation. All other brand and product names are registered trademarks, trademarks, or service marks of their respective holders. NOTICE! Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs, alterations or substitutions of recommended parts made by the user to this equipment not approved by the manufacturer could void the user's authority to operate the equipment in addition to the manufacturer's warranty. This product conforms to the European Union WEEE Directive 2002/96/EC. Do not dispose of this product in a public landfill. Take it to a recycling center at the end of its life. This manual is published by M/A-COM, Inc., without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by M/A-COM, Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of M/A-COM, Inc. Copyright© 2006 M/A-COM, Inc. All rights reserved. MM102558V1 R1A TABLE OF CONTENTS Page REGULATORY AND SAFETY INFORMATION.......................................................................... 6 1.1 1.2 1.3 1.4 1.5 MAXIMUM PERMISSIBLE EXPOSURE LIMITS ................................................................................. 6 DETERMINING MPE RADIUS.................................................................................................................. 6 SAFETY TRAINING INFORMATION ..................................................................................................... 6 REGULATORY APPROVALS ................................................................................................................... 7 SAFETY SYMBOL CONVENTIONS ........................................................................................................ 8 PREFACE ............................................................................................................................................ 9 2.1 ABOUT THIS MANUAL ............................................................................................................................. 9 2.2 GLOSSARY OF TERMS ........................................................................................................................... 10 2.3 CUSTOMER SERVICE ............................................................................................................................. 11 2.3.1 Technical Support........................................................................................................................... 11 2.3.2 Customer Resource Center ............................................................................................................. 12 SPECIFICATIONS ........................................................................................................................... 13 3.1 3.2 3.3 3.4 3.5 3.6 3.7 CABINET..................................................................................................................................................... 13 SOURCE POWER DRAIN ........................................................................................................................ 13 STATION ..................................................................................................................................................... 14 INTERFACE ............................................................................................................................................... 14 TRANSMITTER ......................................................................................................................................... 15 RECEIVER.................................................................................................................................................. 16 INDIVIDUAL EQUIPMENT WEIGHTS................................................................................................. 18 GENERAL INFORMATION........................................................................................................... 19 4.1 REFERENCE MANUALS ......................................................................................................................... 19 4.2 MASTR III ADC STATION OPTIONS.................................................................................................... 20 OPERATION ..................................................................................................................................... 25 5.1 CONVENTIONAL STATION CONFIGURATIONS ............................................................................. 25 5.1.1 Conventional Base Station.............................................................................................................. 25 5.1.2 Conventional Repeater.................................................................................................................... 26 5.1.3 Remote-to-Repeater........................................................................................................................ 26 5.1.4 Transmit Only................................................................................................................................. 26 5.2 ENCRYPTED STATION CONFIGURATIONS...................................................................................... 26 5.2.1 End-to-End Encryption................................................................................................................... 26 5.2.2 RF-Only Encryption/Decryption .................................................................................................... 27 5.3 MODES OF OPERATION......................................................................................................................... 27 5.3.1 Analog FM...................................................................................................................................... 27 5.3.2 Data ................................................................................................................................................ 27 5.3.3 Digital Voice................................................................................................................................... 27 5.4 ENCRYPTION FORMATS ....................................................................................................................... 28 5.4.1 Data Encryption Standard (DES).................................................................................................... 28 5.4.2 Voice Guard Encryption (VGE) ..................................................................................................... 28 5.4.3 Advanced Encryption Standard ...................................................................................................... 29 5.5 P25 CONVENTIONAL CONFIGURATIONS......................................................................................... 29 5.5.1 P25 Conventional Station Operation .............................................................................................. 29 5.5.2 P25 Conventional Repeater Station Operation ............................................................................... 30 5.5.3 P25 Conventional Station with Console ......................................................................................... 30 5.6 PROGRAMMABLE FEATURES FOR CONVENTIONAL STATIONS ............................................. 33 5.6.1 Conventional Stations (Setup) ........................................................................................................ 34 MM102558V1 R1A TABLE OF CONTENTS 5.6.2 5.6.3 5.6.4 5.6.5 5.6.6 5.6.7 5.6.8 5.6.9 5.6.10 5.6.11 5.6.12 5.6.13 Page Main Station Data ...........................................................................................................................34 Push-to-Talk Options ......................................................................................................................36 Other Potentiometer Settings ..........................................................................................................36 Carrier Control Timer .....................................................................................................................36 Squelch Tail Elimination ................................................................................................................37 Drop Out Delay Timer ....................................................................................................................37 Control Shelf Options .....................................................................................................................37 Station Remote Control...................................................................................................................38 Auxiliary Control Relay..................................................................................................................41 Squelch Operated Relay..................................................................................................................41 Channel Guard Monitor ..................................................................................................................41 System Module - Digital Signal Processing....................................................................................42 MASTR III ADC STATION DESCRIPTION ................................................................................ 43 6.1 MASTR III ADVANCED DIGITAL CAPABLE T/R SHELF................................................................43 6.1.1 Interface Board ...............................................................................................................................44 6.1.2 Backplane........................................................................................................................................44 6.2 STATION EQUIPMENT............................................................................................................................48 6.2.1 Station Power Supply......................................................................................................................48 6.2.2 DC Power Distribution Panel..........................................................................................................48 6.2.3 RF Power Amplifier Assembly.......................................................................................................48 6.2.4 RF Antenna Switch Assembly ........................................................................................................49 6.2.5 Cabinet Enclosures and Open Rack Assembly ...............................................................................49 TABLES Table 1-1: Table 2-1: Table 4-1: Table 4-2: Table 4-3: Table 4-4: Table 5-1: Regulatory and Standards Approval List ............................................................................. 7 Glossary of Terms.............................................................................................................. 10 Reference Manuals............................................................................................................. 19 MASTR III ADC Pre-Configured Conventional Station Packages ................................... 20 MASTR III ADC Conventional Station Options and Accessories .................................... 22 MASTR III ADC Programming, Test and Alignment Tools............................................. 24 Typical* Tone Functionality for Tone Remote Control Signaling .................................... 41 FIGURES Figure 2-1: Figure 5-1: Figure 5-2: Figure 5-3: Figure 6-1: Figure 6-2: Figure 6-3: Figure 6-4: Figure 6-5: Figure 6-6: Figure 6-7: Figure 6-8: Figure 6-9: Examples of MASTR III Conventional Base Stations ....................................................... 9 MASTR III P25 Conventional Station Functional Diagram............................................. 31 MASTR III P25 Conventional Simplified Interconnect Diagram .................................... 32 Tone Remote Control Signaling ....................................................................................... 40 Advanced Digital Capable T/R Shelf (Equipped for Conventional FM).......................... 44 MASTR III ADC T/R Shelf Backplane and Interface Board ........................................... 45 Transmitter Synthesizer Module....................................................................................... 45 Receiver Synthesizer Module ........................................................................................... 45 Receiver Front End Module.............................................................................................. 45 Receiver IF Module .......................................................................................................... 46 System Module ................................................................................................................. 46 Data Module ..................................................................................................................... 47 AMPF Module .................................................................................................................. 47 MM102558V1 R1A TABLE OF CONTENTS Page Figure 6-10: Figure 6-11: Figure 6-12: Figure 6-13: Figure 6-14: Figure 6-15: Power Module................................................................................................................. 47 DSP Module ................................................................................................................... 47 120 VAC Switching Power Supply ................................................................................ 48 240 VAC Switching Power Supply ................................................................................ 48 RF Power Amplifier ....................................................................................................... 49 Antenna Switch............................................................................................................... 49 MM102558V1 R1A REGULATORY AND SAFETY INFORMATION 1.1 MAXIMUM PERMISSIBLE EXPOSURE LIMITS DO NOT TRANSMIT with this base station and antenna when persons are within the MAXIMUM PERMISSIBLE EXPOSURE (MPE) Radius of the antenna. The MPE Radius is the minimum distance from the antenna axis that ALL persons should maintain in order to avoid RF exposure higher than the allowable MPE level set by the FCC. FAILURE TO OBSERVE THESE LIMITS MAY ALLOW ALL PERSONS WITHIN THE MPE RADIUS TO EXPERIENCE RF RADIATION ABSORPTION, WHICH EXCEEDS THE FCC MAXIMUM PERMISSIBLE EXPOSURE (MPE) LIMIT. IT IS THE RESPONSIBILITY OF THE BASE STATION OPERATOR TO ENSURE THAT THE MAXIMUM PERMISSIBLE EXPOSURE LIMITS ARE OBSERVED AT ALL TIMES DURING BASE STATION TRANSMISSION. THE BASE STATION OPERATOR IS TO ENSURE THAT NO BYSTANDERS ARE WITHIN THE RADIUS LIMITS. 1.2 DETERMINING MPE RADIUS THE MAXIMUM PERMISSIBLE EXPOSURE RADIUS is unique for each site and is determined during site licensing time based on the complete installation environment (i.e. co-location, antenna type, transmit power level, etc.). Determination of the MPE distance is the responsibility of the installation license. Calculation of the MPE radius is required as part of the site licensing procedure with the FCC. 1.3 SAFETY TRAINING INFORMATION YOUR M/A-COM MASTR® III BASE STATION GENERATES RF ELECTROMAGNETIC ENERGY DURING TRANSMIT MODE. THIS BASE STATION IS DESIGNED FOR AND CLASSIFIED AS “OCCUPATIONAL USE ONLY” MEANING IT MUST BE USED ONLY IN THE COURSE OF EMPLOYMENT BY INDIVIDUALS AWARE OF THE HAZARDOUS RF ENERGY AND THE WAYS TO MINIMIZE EXPOSURE. THIS BASE STATION IS NOT INTENDED FOR USE BY THE “GENERAL POPULATION” IN AN UNCONTROLLED ENVIRONMENT. IT IS THE RESPONSIBILITY OF THE LICENSEE TO ENSURE THAT THE MAXIMUM PERMISSIBLE EXPOSURE LIMITS ARE OBSERVED AT ALL TIMES DURING TRANSMISSION. THE BASE STATION OPERATOR IS TO ENSURE THAT NO BYSTANDERS COME WITHIN THE RADIUS OF THE LIMITS When licensed by the FCC, this base station complies with the FCC RF exposure limits when persons are beyond the MPE radius of the antenna. In addition, your M/A-COM base stations installation complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans: MM102558V1 R1A FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. American National Standards Institute (C95.1 – 1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. American National Standards Institute (C95.3 – 1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields – RF and Microwave. CAUTION 1.4 TO ENSURE THAT YOUR EXPOSURE TO RF ELECTROMAGNETIC ENERGY IS WITHIN THE FCC ALLOWABLE LIMITS FOR OCCUPATIONAL USE, DO NOT OPERATE THE BASE STATION IN A MANNER THAT WOULD CREATE AN MPE DISTANCE IN EXCESS OF THAT ALLOWABLE BY THE FCC. REGULATORY APPROVALS Table 1-1: Regulatory and Standards Approval List TX Frequency Range (MHz) Power Output (Adjustable) (W) FCC ID Number Applicable FCC Rules (47CFR) Industry Canada Certification Number Applicable Industry Canada Rules CE MARK 136-174 10-110 OWDTR-0032-E 22, 90 3636B-0017 RSS-119 N/A 403-450 10-100 OWDTR-0038-E 90 3636B-0038 RSS-119 UHF-L (403-430 MHz) 450-512 10-100 OWDTR-0039-E 22, 90 3636B-0039 RSS-119 UHF-H (450-470 MHz) 806-870 10-100 OWDTR-0036-E 90 3636B-0036 RSS-119 N/A MM102558V1 R1A 1.5 SAFETY SYMBOL CONVENTIONS The following conventions are used to alert the user to general safety precautions that must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere violates safety standards of design, manufacture, and intended use of the product. M/A-COM, Inc. assumes no liability for the customer's failure to comply with these standards. The WARNING symbol calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING symbol until the conditions identified are fully understood or met. CAUTION The CAUTION symbol calls attention to an operating procedure, practice, or the like, which, if not performed correctly or adhered to, could result in a risk of danger, damage to the equipment, or severely degrade the equipment performance. The NOTE symbol calls attention to supplemental information, which may improve system performance or clarify a process or procedure. The ESD symbol calls attention to procedures, practices, or the like, which could expose equipment to the effects of Electro-Static Discharge. Proper precautions must be taken to prevent ESD when handling circuit modules. The electrical hazard symbol is a WARNING indicating there may be an electrical shock hazard present. MM102558V1 R1A PREFACE 2.1 ABOUT THIS MANUAL This manual is written for the communications professional responsible for maintaining MASTR III Advanced Digital Capable (ADC) Conventional or P25 Conventional base station equipment. This manual provides specifications and an overview of the MASTR III ADC Conventional and P25 Conventional base station, and introduces the suite of manuals that provide installation and maintenance instructions for the MASTR III Conventional base stations. 69” Cabinet Installation 37” Cabinet Installation Figure 2-1: Examples of MASTR III Conventional Base Stations MM102558V1 R1A 2.2 GLOSSARY OF TERMS The following is a list of terms and acronyms used in this manual: Table 2-1: Glossary of Terms 10 ADC Advanced Digital Capable AES Advanced Encryption Standard AGC Automatic Gain Circuit AME Adaptive Multi-band Encoding AMPF Adaptive Multi-path Pop Filter CAI Clear Air Interface CAS Carrier Activity Sensor CCT Carrier Control Timer CFR Code of Federal Regulations CG Channel Guard CIU Console Interface Unit COR Carrier Operated Relay CTCSS Continuous Tone Coded Squelch System CTI Centralized Telephone Interconnect CUE Customer Unique Encryption DCG Digital Channel Guard DES Data Encryption Standard DES Digital Encryption Standard DODT Drop Out Delay Timer DSP Digital Signaling Processor DSP Digital Signal Processing DTMF Dual Tone Multi Frequency DVIU Digital Voice Interface Unit E/D Encode/Decode EIA Electronic Industries Alliance FCC Federal Communications Commission FM Frequency Modulation GETC Generic EDACS Trunking Card GMSK Gaussian Minimum Shift Keying ID Identification IF Intermediate Frequency IMBE Improved Multi-Band Exciter LED Light Emitting Diode MM102558V1 R1A 2.3 LO Local Oscillator NRZ Non-Return to Zero P25 Project 25 PA Power Amplifier PC Personal Computer PLL Phased Lock Loop PTT Push-to-Talk RF Radio Frequency RU Rack Unit RX Receive STE Squelch Tail Elimination T/R Transmitter/Receiver TAC Technical Assistance Center TIA Telecommunications Industry Association TX Transmit UHF Ultra High Frequency, refers to the 370-512 MHz Band VG Voice Guard® VGE Voice Guard Encryption VGS Voice Guard Standard VHF Very High Frequency, refers to the 136-174 MHz Band CUSTOMER SERVICE 2.3.1 Technical Support M/A-COM’s Technical Assistance Center (TAC) resources are available to help you with overall system operation, maintenance, upgrades, and product support. TAC is your point of contact when you need technical questions answered. Product specialists, with detailed knowledge of product operation, maintenance, and repair, provide technical support via a toll-free telephone number (in North America). Support is also available through mail, fax, and e-mail. For more information about technical assistance services, contact your sales representative, or call the Technical Assistance Center directly at: North America: 1-800-528-7711 International: 1-434-385-2400 FAX: 1-434-455-6712 E-mail: tac@tycoelectronics.com 11 MM102558V1 R1A 2.3.2 Customer Resource Center If any part of the system equipment is damaged on arrival, contact the shipper to conduct an inspection and prepare a damage report. Save the shipping container and all packing materials until the inspection and the damage report are completed. In addition, contact the Customer Resource Center to make arrangements for replacement equipment. Do not return any part of the shipment until you receive detailed instructions from a M/A-COM representative. Contact the Customer Resource Center at: North America: Phone Number: 1-800-368-3277 (toll free) Fax Number: 1-800-833-7592 (toll free) E-mail: customerfocus@tycoelectronics.com International: Latin America & Asia Pacific: 1-434-455-9217 Europe, Middle-East & Canada: 1-434-455-9219 Fax Number: 1-434-455-6685 E-mail: 12 InternationalCustomerFocus@tycoelectronics.com MM102558V1 R1A SPECIFICATIONS 3.1 CABINET INDOOR CABINET (Floor Mount) 37-inch 69-inch OPEN RACK 83-inch 86-Inch Dimensions [in. (cm)]: Height: 37.0 (94.0) 69.1 (175) 83 (209) 85.5 (217) Width: 21.5 (55.0) 23.1 in. (59) 23-3/16 (59) 21 (53.3) Depth: 18.25 (46.0) 21.0 in. (53.3) 21.0 (53.3) 21 (53.3) Continuous Duty: 121 lbs (55 kg) 576 lbs (261 kg) 693 lbs (314 kg) Packed, Domestic Shipping: 136 lbs (62 kg) 606 lbs (275 kg) 729 lbs (331 kg) Cabinet capacity 17 RU 33 RU 41 RU 46 RU Maximum Radio Units: (using 1-RU power supplies) Weight (with max. number of channels) Rack Units (RU) (1 RU = 1.75 in.) 3.2 SOURCE POWER DRAIN VHF UHF TX Frequency Range (MHz) 136-174 380-512 851-870 RX Frequency Range (MHz) 136-174 370-512 806-825 AC Input Power DC Input Power (A) 800 5A @ 120 VAC or 3A @ 230 VAC VDC Tx 13.8 Rx only 13.8 Tx (full/half power) 26.4 12/8 12/8 12/8 Rx only 26.4 0.5 0.5 0.5 13 MM102558V1 R1A 3.3 STATION General: One RF Station Occupies 8-RU (includes T/R Shelf, RF PA, & 1-RU Power Supply) Service Speaker: 1 watt at 8 ohms Service Microphone: Transistorized Dynamic Duty Cycle (EIA) Continuous: Transmit and Receive at 100% Operating Temperature: -22°F to +140°F (-30°C to +60°C) Humidity (EIA): 90% at 122°F (50°C) Input Power Source: 120 VAC (±20%), 47-63 Hz Optional Input Power Source: 230 VAC (±15%), 47-63 Hz Standby Battery Source: 26.4 VDC, 50 AHR (min.) Antenna Connections: Type N Length of AC Power Cable: 10 ft (3048 mm) Metering: Provided through Handset or TQ0619 Software Altitude: 3.4 Operating: Up to 15,000 ft (4,570 m) Shippable: Up to 50,000 ft (15,250 m) INTERFACE Line Interface: 2-wire or 4-wire (software selectable) Line Cancellation: (2-wire) 20 dB amplitude only (software controllable) Audio (line to transmitter): Line Terminating Impedance: 600 ohms (2-wire or 4-wire) Line Input Level (adjustable): -20 dBm to +7 dBm Frequency Response: ±3 dB @ 300 to 3000 Hz Tone Remote Control: 14 Function Tones (Hz): 1050, 1150, 1250, 1350, 1450, 1550, 1650, 1750, 1850, 1950, & 2050 Secur-it Tone and Transmit Tone: 2175 Hz Permissible Control Line loss @ 2175 Hz: 27 dB MM102558V1 R1A Audio (receiver to line): Audio Amplifier Input Impedance: 10K ohms Input Level: 1 Vrms (for 5 kHz Deviation) Output Impedance to Line: 600 ohms (2-wire or 4-wire) Output Level to Line (1 kHz ref.): +7 dBm (adjustable) Tone (1 kHz ref.): +7 dBm (Reference 7 dBm) Frequency Response: +1 and –3 dB @ 300 to 3000 Hz Hum and Noise, Noise Squelch: -55 dBm (Reference 7 dBm) Tone Squelch: -30 dBm (Reference 7 dBm) DC Remote Control Currents: -2.5 mA, ±6.0 mA, ±11.0 mA Line Loop Resistance (maximum): 3.5 11K ohms (includes 3K ohm termination) TRANSMITTER VHF ANALOG VHF P25 DIGITAL UHF ANALOG UHF P25 DIGITAL 800 MHz ANALOG 800 MHz P25 DIGITAL Frequency Range (MHz) 136 - 174 136 - 174 380 - 512 380 - 512 851 – 870 851 – 870 Rated Power Output (W) 1 10 - 110 10 - 110 10-100 10-100 10 - 100 10 - 100 RF Output Impedance (Ω) 50 50 50 50 50 50 Conducted Spurious and Harmonic Emission -36 dBm -70 dBc -36 dBm -70 dBc -36 dBm -70 dBc ±1.0 ±1.0 ±1.0 ±0.5 external freq. std. ±1.0 ±0.15 external freq. std. 0 to ±5 N/A 0 to ±5.0 N/A 0 to ±5.0 N/A 0 to ±2.5 2.83 kHz nominal per TIA 102 CAAB 0 to ±2.5 ±2.83 nominal per TIA 102 CAAB N/A 2.83 kHz nominal per TIA 102 (CAAB) -55 N/A -55 N/A -55 N/A Frequency Stability (ppm) 2 Modulation Deviation (kHz) Wideband Narrowband FM Noise (dB) Rated power output is measured at the transmitter power amplifier output connector per FCC Certification information. Any customer-required optional items such as power measuring devices and/or duplexers will introduce loss between the transmitter output connector and the station cabinet output connector. This loss will reduce the available power at the station connector. Frequency stability is relative to the stability of the Reference Oscillator. Unless otherwise specified, the value shown in this table is relative to the internal Reference Oscillator signal which is provided by the corresponding Receiver Synthesizer Module. 15 MM102558V1 R1A VHF ANALOG VHF P25 DIGITAL UHF ANALOG UHF P25 DIGITAL 800 MHz ANALOG 800 MHz P25 DIGITAL 12.5/25/30 12.5 12.5/25 12.5 25 12.5 (NPSPAC) 25 Frequency Step Size (kHz) 1.25 1.25 1.25 1.25 6.25 6.25 Frequency Spread Full Spec (MHz) 1.5 1.5 0.5 0.5 Audio Distortion (@ 1 kHz) Less than 3% To Mask 47CFR90.2 10d Less than 3% To Mask 47CFR90.21 0d Less than 3% TX Mask 47CFR90.210 Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 Within +1/- 3 dB of 6 dB/ octave, 300 to 3000 Hz per EIA Mod Fidelity <5% Within +1/- 3 dB of 6 dB/ octave, 300 to 3000 Hz per EIA Mod Fidelity <5% Within +1/- 3 dB of 6 dB/ octave, 300 to 3000 Hz per EIA Mod Fidelity <5% VHF ANALOG* VHF P25 DIGITAL UHF ANALOG* UHF P25 DIGITAL 800 MHz ANALOG* 800 MHz P25 DIGITAL Channel Spacing (kHz) Number of Channels (Conventional) Audio Response (pre-emphasis) 3.6 16 RECEIVER Frequency Range (MHz) 136 - 174 136 - 174 370 - 512 370 - 512 806 - 825 806 - 825 RF Input Impedance (Ω) 50 50 50 50 50 50 Channel Spacing (kHz) 12.5/25/30 12.5 12.5/25 12.5/25 25 12.5 (NPSPAC) 25 12.5 (NPSPAC) Sensitivity (dBm) EIA -116 (12 dB SINAD) (0.35 μV) -116 (5% BER) (0.35 μV) -116 (0.35 μV) -116 (5% BER) -108 faded -118 (0.28 μV) -116 (5% BER) -108 faded Threshold Squelch (dBm) -119 (0.25 μV) N/A -119 (0.25 μV) -119 (0.25 μV) -121 (0.18 μV) N/A MM102558V1 R1A VHF ANALOG* VHF P25 DIGITAL UHF ANALOG* UHF P25 DIGITAL 800 MHz ANALOG* ≥60 dB Dig ACR ≥20 dB (NPSPAC) 800 MHz P25 DIGITAL Selectivity 2- Signal 12.5 kHz ≥75 dB 25 kHz ≥85 dB N/A ≥85 dB N/A ≥80 dB N/A 30 kHz ≥90 dB N/A N/A N/A N/A N/A Frequency Stability (ppm) ±1.0 ±1.0 ±1.0 ±0.5 ±1.0 ±0.15 external freq. std. 12.5 kHz ±1.0 ±1.0 ±2 N/A ±1.6 (NPSPAC) ±1.0 25 kHz ±2.0 N/A ±1 ±1 ±2 N/A 12.5 kHz ≥75 ≥80 ≥75 ≥80 N/A ≥80 25 kHz ≥80 N/A ≥80 N/A ≥80 N/A 30 kHz ≥80 N/A N/A N/A N/A N/A Spurious and Image Rejection (dB) ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 Full Specs. (MHz) 2.0 2.0 2.0 2.0 0.5 0.5 1 @ <3% distortion N/A 1 @ 3% distortion N/A 1 @ 3% distortion N/A ≥60 dB Dig ACR ≥75 dB ≥80 dB Signal Displacement Bandwidth (kHz) Intermodulation (dB) Audio Output @ 1000 Hz, 25/30 kHz Channel (W) * Audio Response (de- emphasis): Within +2/-8 dB of 6 dB/octave (@ Local Speaker), 300 to 3000 Hz per EIA Within +1/-3 dB of 6 dB/octave (@ Line Output), 300 to 3000 Hz per EIA. 17 MM102558V1 R1A 3.7 INDIVIDUAL EQUIPMENT WEIGHTS UNIT OR ASSEMBLY Lbs kg 69-inch cabinet w/ doors and fan assembly 176 80 Power Supply 19A149978 38 17 Switching Power Supply PS103010 8.91 4.04 T/R Shelf (without plug-in modules) 9.6 4.35 22.25 10.21 System Module 1.5 0.68 Power Module 1.8 0.82 TX Synthesizer 1.9 0.86 RX Synthesizer 2.15 0.93 RX Front End Module 2.35 1.07 RX IF Module 1.75 0.79 Blank module panel 0.4 0.18 Power Amplifier, 19D902797 20.8 9.43 Power Amplifier, EA101292 9.8 44.45 SureCall Test Unit (with radio) 20 9.07 T/R Shelf (with plug-in modules) 18 WEIGHT MM102558V1 R1A GENERAL INFORMATION 4.1 REFERENCE MANUALS It may be necessary to consult one or more of the following manuals. The manuals listed in Table 4-1 may provide additional guidance if you encounter technical difficulties during the installation or testing process. Table 4-1: Reference Manuals DESCRIPTION MANUAL NUMBER MASTR III Base Station MASTR III ADC Base Station Installation Manual MASTR III ADC Application and Assembly Diagrams MASTR III ADC T/R SHELF MM102554V1 MM102555V1 MM102244V1 System Module (19D902590G6) LBI-39176 Power Module (19D902589G2) LBI-38752 MASTR III RF PACKAGE: VHF (136 - 174 MHZ) MM102557V1 Transmit Synthesizer Module (EA101685V1, V2) MM102174V1 Receive Synthesizer Module (EA101684V1, V2) MM102819V1 Receiver Front End Module (19D902782G1, G2) LBI-38642 Receiver IF Module (EA101401V1) MM101886V1 Power Amplifier (EA101292V10, V11, & V12) MM101383V2 MASTR III RF PACKAGE: UHF (380 - 512 MHZ) MM102557V2 Transmit Synthesizer Module (EA101685V11, V12, V13) MM102174V2 Receive Synthesizer Module (EA101684V11, V12, V13) MM102819V2 Receiver Front End Module (19D902782G6, G8, G9, G10, G11, & G12) LBI-39129 Receiver IF Module (EA101401V1) MM101886V1 Power Amplifier (EA101292V21, V22) MM101292V3 MASTR III RF PACKAGE: 800 MHz MM102557V3 Transmit Synthesizer Module (EA101685V5) MM102147V3 Receive Synthesizer Module (EA101684V5) MM102819V3 Receiver Front End Module (19D902782G5) LBI-39028 Receiver IF Module (EA101794V1) MM102407V1 Power Amplifier, 100 Watt (EA101292V1) MM101383V1 19 MM102558V1 R1A OPTIONS AND ACCESSORIES MASTR III Adaptive Multi-path POP Filter (AMPF), Option SXDE9C: Installation Manual: Maintenance Manual: MASTR III Data Module, Option SXDE5B: 19D904558G1 Rev. 1 and earlier: 19D904558G1 Rev. A and later: AE/LZT 123 3244/1 AE/LZB 119 3149/1 LBI-38918 MM-008429-001 Site Grounding and Protection Guidelines AE/LZT 123 4618/1 Tower Requirements and General Specifications LBI-39185 Base Station Switching Power Supply Maintenance Manual (PS103010V120) MM22315 AC Outlet Strip Maintenance Manual LBI-4841 Blower Kit Maintenance Manual LBI-4842 MASTR III Fuse Panel (12/24 Volt) Maintenance Manual LBI-30246 TEST AND PROGRAMMING RF Module Test Fixture (TQ0650) - Model TS101285V11 - Model 344A4153P1 MASTR III Programming Guide (TQS3353) 4.2 MM101885V1 LBI 38805 MM102518V1 MASTR III ADC STATION OPTIONS The MASTR III ADC Conventional base station is available in the following configurations and may be combined with the options listed. A brief description of individual modules, hardware and features listed below can be found in later sections of this manual. Table 4-2: MASTR III ADC Pre-Configured Conventional Station Packages PRE-CONFIGURED STATION PACKAGES OPTION DESCRIPTION UNENCRYPTED MASTR III STATIONS, PRE-CONFIGURED MODELS IN 37” CABINET SXHMC1 STATION, CONVENTIONAL MASTR III PACKAGE, 150.8-174 MHZ, 110W Includes power supply, 37-inch cabinet, antenna switch and mounting hardware. SXUMC1 STATION, CONVENTIONAL MASTR III PACKAGE, 450-470 MHZ, 100W Includes power supply, 37-inch cabinet, antenna switch and mounting hardware. UNENCRYPTED MASTR III STATIONS (CONFIGURED WITH T/R SHELF AND RF PA ONLY) (Cabinet, Power Supply, Antenna Switch, Mounting Hardware and other options must be ordered separately) 20 SXGMCX STATION, CONVENTIONAL MASTR III, 136-150.8 MHZ, 110W SXHMCX STATION, CONVENTIONAL MASTR III, 150.8-174 MHZ, 110W SX8MCX STATION, CONVENTIONAL MASTR III, 806-870 MHZ, 100W MM102558V1 R1A SXUMCX STATION, CONVENTIONAL MASTR III, 450-470 MHZ, 100W SXWMCX STATION, CONVENTIONAL MASTR III, 492-512 MHZ, 90W SXVMCX STATION, CONVENTIONAL MASTR III, 470-494 MHZ, 90W SXTMCX STATION, CONVENTIONAL MASTR III, 425-450 MHZ, 90W SXPMCX STATION, CONVENTIONAL MASTR III, 410-430 MHZ, 90W SXRMCX STATION, CONVENTIONAL MASTR III, 403-425 MHZ, 90W AEGIS™/VOICE GUARD OPTIONS (FOR UNENCRYPTED MASTR III STATIONS ONLY) END-TOEND ENCRYPTION SXVG3F KIT, GETC, AEGIS/VOICE GUARD, END-TO-END REMOTE/REPEATER With modem (for tone remote or tone remote/repeater stations with end-to end encryption). NOTE: No encryption or decryption occurs in the Aegis Station shelf. SXVG3E KIT, GETC™, AEGIS/VOICE GUARD, END-TO-END (For standalone repeaters.) NOTE: No encryption or decryption occurs in the Aegis Station shelf. ENCRYPTED MASTR III STATIONS, (INCLUDES CONFIGURED T/R SHELF AND RF PA ONLY) (Cabinet, Power Supply, Antenna Switch, Mounting Hardware and other options must be ordered separately) SXGMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 136-150.8 MHZ, 110W SXHMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 150.8-174 MHZ, 110W SXGMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 136-150.8 MHZ, 110W SX8MCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 806-870 MHZ, 100W SXUMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 450-470 MHZ, 100W SXWMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 492-512 MHZ, 90W SXVMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 470-494 MHZ, 90W SXTMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 425-450 MHZ, 90W SXPMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 410-430 MHZ, 90W SXRMCXE STATION, 64-BIT ENCRYPTION, CONVENTIONAL MASTR III, 403-425 MHZ, 90W MASTR III PAGING STATIIONS (FOR TRANSMIT ONLY APPLICATIONS) (Cabinet, Power Supply, Mounting Hardware and other options must be ordered separately) SXUMDX TRANSMITTER, CONVENTIONAL MASTR III, 450-470 MHZ, 100W SXHMDX TRANSMITTER, CONVENTIONAL MASTR III, 150.8-174 MHZ, 110W SXGMDX TRANSMITTER, CONVENTIONAL MASTR III, 136-150.8 MHZ, 110W 21 MM102558V1 R1A Table 4-3: MASTR III ADC Conventional Station Options and Accessories OPTIONS AND ACCESSORIES OPTION DESCRIPTION ENCRYPTION/DECRYPTION MODE FOR REMOTE OR REMOTE/REPEATER (ENCRYPTED MASTR III STATIONS ONLY) SXVG3D KIT, DES 1027 ENCRYPTION SHELF (INCLUDES GETC). Same as Option SXVV1N except uses DES algorithm. SXVW1J KIT, DES ENCRYPTION SHELF (INCLUDES GETC). Same as Option SXVV1N except uses DES algorithm. SXVV1N KIT, VGE ENCRYPTION SHELF (INCLUDES GETC). Provides encryption/decryption in a tone remote/repeat station. Module is remotely controlled using function tones. VGE algorithm version. REMOTE OR REMOTE/REPEATER (FOR UNENCRYPTED MASTR III STATIONS ONLY) SXVV1S KIT, AEGIS UNENCRYPTED SHELF (INCLUDES GETC). Provides non-encrypted Aegis digital communications in a tone remote/repeat station. Module is remotely controlled using function tones. HARDWARE, OPTIONS AND ACCESSORIES 22 SXCA1U CABINET, 83 IN. SXCA1D CABINET, 69 IN. SXCA1S CABINET, 37 IN. SXMR1D OPEN RACK, 86 IN. SXCA1X CABINET, 45 IN., OUTDOOR SXMN2B OPTION, NO CABINET SXFN1A FAN, 120 VAC, Must be included when installing more than 1 repeater in a 69- or 83-inch cabinet. SXFA1L FAN, 230 VAC, Must be included when installing more than 1 repeater in a 69- or 83-inch cabinet. SXFA1N FAN, 12 VDC, Must be included when installing more than 1 repeater in a 69- or 83-inch cabinet. SXCN1Z OUTLET STRIP, 120 VAC SXMN9H COVER, CABINET TOP, 69/83 IN. CABINET (CONVENTIONAL) SXMN7F KIT, MOUNTING HARDWARE, 37 IN. CABINET SXMN3Y KIT, MOUNTING HARDWARE, 69/83/86 IN. CABINET/RACK SXMN9C COVER, SCREEN, T/R SHELF MM102558V1 R1A OPTIONS AND ACCESSORIES OPTION DESCRIPTION SXCH1M CHARGER, UHF ONLY, BATTERY STANDBY, 230 VAC, 50 HZ, Same as SXCH1L except 230 VAC/50 Hz. SXPS5Y POWER SUPPLY, 230 VAC, 50 HZ, 12/24 VDC, 3/15A For 800 MHZ and VHF applications SXPS9R POWER SUPPLY, 120 VAC, 60 HZ, 12/24 VDC, 6/15A Output SXCL5Z CABLE, CHARGER TO BATTERY, For use with SXPS9R SXCL6A KIT, GEL CELL SHELF WITH COVER AND CABLE, For use with SXPS9R SPK0501 KIT, GEL CELL SHELF CABLES, Kit, contains cables only SXPD1M PANEL, FUSE, 12/24 VDC 2401 BATTERY, UHF ONLY, GEL CELL, 12 VDC, 26 AH, For use in battery shelf option. Order 4 units per base station. SXSU3A KIT, ANTENNA SWITCH SXSU3J KIT, ANTENNA SWITCH, RAIL MOUNTED SXDU1K DUPLEXER, Factory Installed, 162-174; 2-12 MHZ MAXIMUM SEPARATION Band pass/Band reject, 162-174 MHz 2-12 MHz Rx/Tx separation, maximum insertion loss 1.5 dB. SXDU1J DUPLEXER, Factory Installed, 150-162; 2-12 MHZ MAXIMUM SEPARATION Band pass/Band reject, 150-162 MHz 2-12 MHz Rx/Tx separation, maximum insertion loss 1.5 dB. SXDU1M DUPLEXER, Factory Installed, 450-470 MHZ, 5-30 MHz Rx-Tx sep. SXDE5B KIT, TX DATA, Provides Voice/Data mode selection. In the data mode, the module will accept NRZ (nonreturn to zero) digital input (single polarity or dual polarity in the range of -25 to +25 volts) at speeds up to 9600 bits/sec. (VHF/UHF only, 25 kHz channel only) SXMK3J KIT, RADIO LINK APPLICATION, Modifies a standard base station into a radio link repeater. Provides harness and programming to change a simplex tone remote station into a radio link repeater. Used in conjunction with option applied to another standard base station to complete the Radio Link application. SXSU3D KIT, SOR RELAY, Provides relays and hardware for SOR and Auxiliary Control. SXMC3B MICROPHONE, MOBILE (SERVICE) SXMK3S KIT, SETUP, MASTR III STATION WITH MIII AUXILIARY RX, Provides cabling and hardware for MASTR III Auxiliary Receiver. Limited to one RX frequency on base stations. SXSF1W FEATURE, VOTING TONE (1950 HZ), Includes 4-wire audio. SXSF3J FEATURE, 4 WIRE AUDIO Enable remote station to operate with 4-wire control. 23 MM102558V1 R1A OPTIONS AND ACCESSORIES OPTION DESCRIPTION SXMK3K INSTRUCTION, BACK-TO-BACK REPEATER/STATION #2, This option is applied to a 2nd standard base station and is used in conjunction with SXMK3J which is applied to the 1st station. SXMF5H PROGRAMMING, 12.5 KHZ CHANNEL, Factory configured station for narrowband operation (UHF/VHF Conventional FM Voice Only). Table 4-4: MASTR III ADC Programming, Test and Alignment Tools PROGRAMMING, TEST AND ALIGNMENT 24 OPTION DESCRIPTION TQS3353 MASTR IIE/MIII PROGRAMMING SOFTWARE, Provides capability of changing radio's functions and features. Includes TQ0619 Utility Programming Software. TQS0653 MASTR IIE/MASTER III MSEDIT SOFTWARE, Provides access to special programming features. SPK9024 UTILITY HANDSET TQ3356 MASTR IIE/MIII PROGRAMMING CABLE TQ0650 MODULE ALIGNMENT AND TEST KIT EA24877-0001 EXTENDER BOARD, For “EA” Series RF Modules 188D5338G1 EXTENDER BOARD, System, Control and Power Modules 193D1094G1 Multi-Purpose Module MM102558V1 R1A OPERATION The MASTR III ADC station is a RF synthesized computer programmable, Frequency Modulated (FM) transceiver capable of wideband (25 kHz) or narrowband (12.5 kHz) operation. The MASTR III ADC station combines modular design and state-of-the-art technology to deliver superior performance and reliability. MASTR III ADC station incorporates fully shielded and removable modules, front-mount controls, and remote diagnostics. The station is capable of 100% transmitter duty cycle with simultaneous receive capability allowing repeater operation. The MASTR III ADC station hardware may be installed in 19” rack mount cabinets or 19” open racks. Equipment cabinets are equipped with front and rear doors for full equipment access, key lock security and available in 37”, 69” and 83” heights. The 86”open-rack is designed to be floor mounted and allows full accessibility to all sides of the equipment. Power Supply options for the MASTR III ADC station include 120 VAC or 240 VAC input at 47 Hz to 63 Hz, battery backup options and DC Power Distribution equipment. The MASTR III ADC station may be equipped with an antenna switch relay for stand-alone base station configurations, antenna duplexers for stand-alone repeater configurations, or transmitter combiners and receiver multi-couplers for multi-station installations. The MASTR III ADC station may be configured as a Conventional Analog or P25 Conventional station. 5.1 CONVENTIONAL STATION CONFIGURATIONS The MASTR III ADC station is available in Conventional VHF, UHF, and 800 MHz versions and can be configured to operate as any of the following: • Conventional Base Station (2-wire or 4-wire audio1) • Conventional Repeater (Stand-alone, no wire line) • Conventional Repeater (with wire line control) • Remote-to-Repeater • Transmit Only (Paging or other Data Applications) 5.1.1 Conventional Base Station When configured as a Conventional Base Station, the MASTR III ADC station may be further configured to operate with 2-wire or 4-wire controllers, providing access to many remote control features including up to twelve (12) selectable RF channels. Each channel can be individually programmed for either simplex operation (common TX and RX frequency) or half-duplex operation (different TX and RX frequency). Each channel may be programmed for any combination of standard sub-audible tone Channel Guard or Digital Channel Guard. In standard DC control applications, up to 2 RF channels, RX Channel Guard Disable (monitor) and scan features may be controlled using loop currents of +6 mA, +11 mA, -6 mA, -11 mA and -2.5 mA. E&M control is a feature of DC control. In standard Tone Remote control applications, up to four (4) channels may be accessed via Tone Remote Control. Other features such as RX Channel Guard Disable (monitor), Scan and Repeater Enable may also be tone controlled. Additionally, Dual Tone Multi Frequency (DTMF) signaling sent via the wire line connection can be used in conjunction with DC or Tone Remote control to allow control of up to twelve (12) selectable channels. 25 MM102558V1 R1A DTMF tones are sent to the station via the wire line interface where the System Module decodes the tones as channel assignment information. The DC or Tone Remote signaling then controls the TX/RX operations of the station on the channel selected by the DTMF signaling. 5.1.2 Conventional Repeater When configured as a Conventional Repeater, the MASTR III ADC station provides full duplex (different TX and RX frequencies operating simultaneously) operation as a single channel repeater station. The repeater may be programmed for any standard Channel Guard, Digital Channel Guard or Type-90 tone. MASTR III ADC stations configured for repeater operation may also be configured for DC or Tone Remote control. Console TX and RX, Channel Guard disable and repeater enable are common features available using 2-wire or 4-wire remote control. 5.1.3 Remote-to-Repeater When configured as a Remote-to-Repeater station, the MASTR III ADC station provides full duplex repeater operation just like Conventional Repeaters, with extended capability to share TX, RX and control operations via 4-wire interfacing with another MASTR III ADC station operating as a Remote Base. The Remote Base station can be co-located or remotely located at another site. 5.1.4 Transmit Only MASTR III ADC stations operating as Transmit Only stations provide the necessary equipment to operate as a One-Way Paging Station or other similar Data transmitters. Only transmitter related modules and components are provided with the station T/R shelf. A Data Module is provided for 9600 bps NRZ TX data capability. The Data Module provides the required 12.8 MHz reference oscillator signal to the TX Synthesizer, thus meaning no RX Synthesizer is required (the usual source for the 12.8 MHz reference oscillator signal). 5.2 ENCRYPTED STATION CONFIGURATIONS MASTR III ADC stations equipped with external encryption equipment may be configured one of two ways: • End-to-End Encryption • RF Only Encryption/Decryption 5.2.1 End-to-End Encryption With end-to-end encryption, the voice encryption occurs at the dispatch center or originating radio and remains encrypted all the way to the properly equipped mobile or portable radio. External encryption equipment is located at or nearby the dispatch center and connected to the MASTR III ADC station via four-wire interconnection. This method of operation provides the highest level of system security. However, four-wire interconnection with one or more consoles is always in the clear mode. This assumes that the dispatch center is secure and that the console interconnection will be by short, local cable runs that are adequately secure. With end-to-end encryption, Cryptographic key information is not required at the MASTR III ADC station is located. All key loading occurs at the dispatch center or originating radio where the external encryption equipment is located. 26 MM102558V1 R1A 5.2.2 RF-Only Encryption/Decryption In RF-Only Encryption/Decryption (E/D) stations, external encryption equipment is connected directly to the MASTR III ADC station. The voice signal is always delivered clear (unencrypted) from the dispatch center to the base station where it can then be encrypted and sent over the radio path to properly equipped mobiles and portables. One or more station consoles operate in a standard clear mode, tone control configuration. In an RF only E/D station, the working cryptographic key must reside in the external encryption equipment co-located at the MASTR III ADC station site. The external encryption equipment is remotely controlled to select for CLEAR or GUARDED modes of operation at the start of each transmit PTT, receive mode selection is automatic. Four-wire control is still a requirement but only a voice grade (not data grade) circuit is required. 5.3 MODES OF OPERATION Options are available for conventional MASTR III ADC stations to provide the following modes of communication: • Analog FM (Clear Voice) • Data (Paging and other externally generated NRZ Data formats) • Digital Voice (unencrypted AEGIS) • Digital Voice Encryption (Encrypted Voice Guard or encrypted AEGIS) 5.3.1 Analog FM When operating in conventional analog mode, the MASTR III ADC station communicates via traditional FM modulation schemes. Narrowband (12.5 kHz) bandwidth is available on the VHF and UHF stations while Wideband (25 kHz) bandwidth is available on the VHF, UHF and 800 MHz bands. Both the TX and RX audio circuitry is designed to provide extremely clear audible speech characteristics from 300 Hz to 3000 Hz, with sub-audible tone capability for Channel Guard requirements. 5.3.2 Data The MASTR III ADC station may be equipped with a Data Module capable of delivering up to 9600 bps Non-Return-to-Zero (NRZ) serial data transmissions. This mode of operation provides the necessary digital interfacing required for paging and other externally generated data formats. 5.3.3 Digital Voice The MASTR III ADC station may be equipped with an external Digital Voice Interface Unit (DVIU) capable of encoding and decoding digital signaling. Stations equipped with the external DVIU can provide one of several digital voice formats, each having certain types of encrypted or unencrypted services available. The formats and types are as follows: • Voice Guard (DES and VGE) • AEGIS (Unencrypted AEGIS, Encrypted with DES, VGE or VGS) • P25 Conventional (Unencrypted P25, Encrypted with DES and AES) 27 MM102558V1 R1A 5.3.3.1 Voice Guard Voice Guard is the first generation digital voice format available only as an encrypted signal. Voice Guard signals use Gaussian Minimum Shift Keying (GMSK), running at 9600 bps, two level FM modulation, Non-Return-to-Zero (NRZ), serial data. This means that the data is a serial train of two-state data bits (i.e., ones and zeros) occurring at the rate of 9600 bits per second. The NRZ characteristic means that the duration of each data bit is a full clock period (approximately 104 microseconds) instead of returning to zero before the next bit time starts. Voice Guard is available in two types of encryption provided by either of two different algorithms. These algorithms are: • Data Encryption Standard (DES) • Voice Guard Encryption (VGE) These algorithms are the mathematical manipulations used to scramble the digitized voice bit pattern. Both algorithms offer the user a higher level of voice security by virtue of the extremely large number of available cryptographic keys. The availability of encryption devices are subject to national and international export laws. 5.3.3.2 AEGIS AEGIS is a second generation digital voice format, available in both encrypted and unencrypted formats. AEGIS uses Adaptive Multi-band Encoding (AME). AME offers enhanced voice quality characteristics over Voice Guard technology. AEGIS operates at 9600 bps, two level FM, with encryption provided by DES or VGE algorithms. 5.4 ENCRYPTION FORMATS 5.4.1 Data Encryption Standard (DES) DES is a public domain encryption system. DES employs a 64 bit cryptographic key, 56 bits of which are used for encryption and the remaining eight bits are parity bits. This results in 7.2 times 10 to the 16th power unique cryptographic keys being available. The security of a DES equipped system is a result of the extremely large number of available keys. 5.4.2 Voice Guard Encryption (VGE) The VGE algorithm is a very secure, proprietary, encryption algorithm which was developed to meet the security needs of international and domestic customers. The encryption algorithm utilizes highly complex non-linear data spreading and iterative key scheduling to insure the security of encrypted voice data. The VGE algorithm utilizes a 64-bit cryptographic key, and thus offers the security of 1.8 times 10 to the 19th power permutations of keys. It also utilizes a key scheduling algorithm, bit permutations, and nonlinear product transformations to provide a very high level of bit spreading. Unlike DES, the VGE algorithm offers an additional level of security, in the form of Customer Unique Encryption (CUE). The programming of a second 64-bit CUE code (16hex characters) allows a user increased security. Even if two parties use the same cryptographic key, their equipment will not communicate unless they use the same CUE. This, effectively, increases the number of key and CUE permutations to 3.4 times 10 to the 38th power, equivalent to 128-bit encryption. VGS is a customer unique, customer specific encryption algorithm that works very similar to VGE. 28 MM102558V1 R1A 5.4.3 Advanced Encryption Standard Advanced Encryption Standard (AES) is a block cipher format approved for use as an encryption standard by the U.S. government. AES is fast in both software and hardware, is relatively easy to implement, and requires little memory. AES is currently used in conjunction with the P25 technology. Unlike DES, AES operates as a substitution-permutation network. AES utilizes fixed blocks of data formed into tables. AES has a fixed block size of 128 bits and a key size of 128, 192 or 256 bits. AES uses a process of shifting data in a table. The bit shifting techniques are known as AddRoundKey, SubBytes, ShiftRows and MixColumns. This combination of block data, bit shifting and unique key driven encryption methodologies provide much further advanced encryption capabilities than DES or VGE. 5.5 P25 CONVENTIONAL CONFIGURATIONS VHF and UHF MASTR III ADC stations may be equipped with a DSP Module to allow operation as a Project 25 (P25) Conventional station. P25 compliant stations use four-level FM modulation (C4FM), and are backward compatible with traditional analog FM radios. P25 Conventional technology supports the following modes of communication: • P25 Conventional Base Station (4-Level FM) • P25 Conventional Repeater • P25 Conventional Repeater with Console Control P25 is an Industry Standard developed to bring Interoperability between different manufacturers, and users of their respective digital communications equipment. P25 technology uses a standardized digital format known as Common Air Interface (CAI). CAI incorporates various system information and a digital voice format into one digital transmission. While the DSP card located in the MASTR III ADC station provides the P25 formatting, external equipment is required to encrypt the voice product delivered to the station. External encryption equipment for P25 Conventional systems is available for three types of encryption: • DES • VGE • AES The encryption formats are discussed in Section 5.4. 5.5.1 P25 Conventional Station Operation MASTR III ADC stations operating in P25 Conventional mode utilize additional circuitry in the RX IF Module to provide the properly filtered and amplified signal required by the DSP Module to decode the signal. The DSP Module also provides the encoded C4FM signaling for the transmitter. In the 21.4 MHz RX IF module (VHF and UHF stations), the 455 kHz four-level FM signal passes through additional IF filtering, a differential amplifier, and a buffer to the 455kHzIF lines on the backplane. Unlike 2-level signals, the signals present on the 455kHzIF lines are not demodulated. These lines connect to the DSP Module input where the DSP captures the data signal and processes it as necessary. During TX operations, the DSP Module encodes the inbound audio or digital signal into the P25 compliant C4FM modulation scheme and routed via the backplane to the TX Synthesizer Module. 29 MM102558V1 R1A 5.5.2 P25 Conventional Repeater Station Operation In the P25 Repeater mode, the DSP Module uses the Delay PTT In line and the Remote PTT to communicate with the System Module. After the DSP Module demodulates a four-level FM signal, it asserts a Delay PTT In signal to the System Module, indicating a P25 call is being received. While the Delay PTT In line is applied, the System Module keys the External PTT and disables the Channel Guard circuitry, preventing further processing of the 455 kHz signal on the VOL-SQ HI line. The four-level FM signal is passed onto the System Module on the EXT HSD line. The System Module processes the signal and sends it to the TX Synthesizer Module on the TX Audio Hi line. The External PTT also keys the transmitter and the signal is re-transmitted. The DSP module continues to assert the Delay PTT In line until the P25 Terminating Data unit is transmitted. While the External PTT is keyed, the DSP passes the demodulated analog audio to the System Module on the MDM Line TXD. The System Module routes the audio to the landline interface for monitoring by the Console. 5.5.3 P25 Conventional Station with Console 5.5.3.1 Console Transmit The MASTR III P25 Conventional Base Station also supports analog remote control through the base station’s 2- or 4- wire landline interface. When communication is initiated by a remote console, the analog audio is routed through the Interface Card to the System Module. The System Module routes the audio on MDM Line RXD to the DSP Module. The System Module also sends a Remote PTT signal to the DSP Module, initiating the four-level FM modulation process. The DSP Module asserts a Delay PTT In signal to the System Module, indicating a P25 is being sent. The System Module executes an External PTT, this keys the transmitter and the signal is transmitted. The modulated four-level FM signal is passed on to the System Module on the EXT HSD line. The System Module processes the signal and sends it to the TX Synthesizer Module on the TX Audio Hi line. The DSP module continues to assert the Delay PTT In line until the call is complete and the P25 Terminating Data unit is transmitted. 5.5.3.2 Console Preempt The Console Preempt feature allows a dispatcher’s call to preempt a radio call already in progress. This means the dispatcher’s call is heard by all radios and the transmitting radio is still heard by the dispatcher. The Console Preempt feature assumes a P25 call is in process (see section 4.2). When the console initiates a call, the analog audio is routed through the Interface Card to the System Module. The System Module routes the audio on MDM Line RXD to the DSP Module and sends a Remote PTT signal to the DSP Module. The DSP Module initiates the four-level FM modulation process of the console audio. It then switches from sending the P25 call to sending the four-level FM modulated console audio to the System Module on the EXT HSD line. The System Module processes the signal and sends it to the TX Synthesizer Module on the TX Audio Hi line. The System Module continues executing an External PTT, keying the transmitter and transmitting the console signal. At the end of the console call, the DSP Module sends the P25 Terminating Data unit. If the P25 Repeat call still exists, the DSP Module continues to assert the Delay PTT In line until the call is complete and the P25 Terminating Data message is transmitted. 30 MM102558V1 R1A Figure 5-1: MASTR III P25 Conventional Station Functional Diagram 31 MM102558V1 R1A Figure 5-2: MASTR III P25 Conventional Simplified Interconnect Diagram 32 MM102558V1 R1A 5.6 PROGRAMMABLE FEATURES FOR CONVENTIONAL STATIONS Most MASTR III ADC station features may be accessed using a PC compatible computer and the latest version TQS3353 Programming Software. Station configurations discussed in Section 5 require features to be properly set via programming software. Most MASTR III ADC feature programming is stored in the Station’s System Module. This section of the manual is written to describe the programmable features of the MASTR III ADC station and how they apply to Conventional and P25 Conventional base and repeater station operation. When programming a MASTR III ADC station, it is advisable to read and save (archive) the personality from the station before attempting to program features. Always save (archive) any programming changes to a different filename to preserve the original personality in case the changes you have made are unsuccessful. Programmable features discussed in this section include the following: • • Conventional Stations (Setup) Potentiometer Settings (Pots) • More Features (Additional) No Remote DC Remote Carrier Control Timer Tone Remote Squelch Tail Elimination Type 90 Drop Out Delay Timer DTMF • Main Station Data (New) Control Shelf (Options) Morse Code ID Transmit and Receive Frequency Battery Alarm Channel Guard Logic Standby TX Pot Intercom CG Pot Bandwidth RF Simplex and Rpt Receiver Channel Scan o PA Power • • Push-to-Talk Options (PTTs) • Station Remote Control Two-Wire/Four Wire Operation Repeat PTT DC Remote Control Remote PTT Tone Remote Control Local PTT Auxiliary Control Relays External PTT Squelch Operated Relay Morse Code ID PTT Channel Guard Monitor System Module - DSP 33 MM102558V1 R1A 5.6.1 Conventional Stations (Setup) The initial Setup screen in the TQS3353 software allows the station to be defined as one of several Conventional station types include: No Remote, DC Remote, Tone Remote, Type 90 and DTMF. Other station types appear in the Setup screen however only the above are applicable to Conventional stations. The other station types are: Simulcast, Trunked and Multi-Receiver. 5.6.1.1 No Remote This type of station configuration is typically selected when the station will be operating as a stand-alone repeater. As the name implies, no remote control features will be activated during this mode. 5.6.1.2 DC Remote Base, Repeater, and Transmit-only stations may be controlled remotely via 2-wire or 4-wire telephone line connections using DC Remote control signaling. DC Remote control uses a DC loop current placed on the phone line to remotely control certain preprogrammed station features such as TX PTT, channel selection and CG Enable/Disable. Further information on 2-wire and 4-wire operation may be found in Section 5.6.9.1, and further information about DC Remote control may be found in Section 5.6.9.2 5.6.1.3 Tone Remote Similar to DC Remote control, Tone Remote control uses audible control tones sent via the phone line to remotely access certain preprogrammed station features such as TX PTT, channel selection and CG Enable/Disable. Further information may be found in Section 0. 5.6.1.4 Type 90 With Type 90 (T90) signaling, a station is setup to accept a burst of single-tone transmitted by a mobile or portable at the beginning of a transmission which activates certain base or repeater station functions such as CG Disable or Repeater Enable. For example: when T90 is used to control the Repeater Enable function and the System Module detects the proper T90 signal, the repeater is keyed and operates in carrier squelch, CG or DCG tone mode until one of three things occur: the repeater’s receiver is squelched, the repeater’s Drop Out Delay Timer is reset, or the repeater Time Out Timer un-keys the station and the repeater is disabled until the next valid T90 tone is received. There are ten (10) different T90 tones available: 1050 Hz, 1200 Hz, 1350 Hz, 1500 Hz, 1650 Hz, 1800 Hz, 1950 Hz, 2100 Hz, 2250 Hz, and 2400 Hz. 5.6.1.5 DTMF When DTMF is selected, the station is setup to function as a repeater and uses over-the-air DTMF signaling to enable or disable the repeater and to make channel selections when multiple receive or transmit frequencies are assigned during special applications. 5.6.2 Main Station Data Main station data may be programmed using the New, Change or Read tabs in the TQS3353 programming software. The New tab allows the programmer start with a clear database thereby requiring all parameters and features to be properly programmed from scratch. The Change tab allows the programmer to modify an existing data file previously stored to hard drive. The Read tab allows the programmer to read and save the station personality while directly connected to the station’s Data port. 34 MM102558V1 R1A The main programmable station data parameters include Transmit and Receive frequency, Channel Guard, TX Pot settings, CG Pot settings, RF Simplex/Rpt and PA Power settings. The following sections include a brief description of each parameter. 5.6.2.1 Transmit and Receive Frequency The System Module is programmed with most of the station’s features including transmit and receive frequency assignment. Once the correct control station type has been defined, up to twelve (12) channels may be programmed into one station (16 channels in models with previous vintage System Modules). 5.6.2.2 Channel Guard A Channel Guard (CG) is a sub-audible (below 300 Hz) tone, used to control one or more functions of a base or repeater station. CG tones may be used to open (or un-mute) the station’s receiver audio circuit, provide PTT signaling to stations in repeater mode, or provide control of other station functions. There are two types of Channel Guard (CG) available: • Tone Channel Guard (CG) • Digital Channel Guard (DCG) The System Module, located in the MASTR III ADC T/R Shelf, can encode CG or DCG tones (generate tones to be used by the transmitter) or decode received CG or DCG tones. The System Module may be programmed with different CG or DCG tones on each channel. Each individual channel may also have a different transmit and receive CG or DCG tone; including a mix, such as DCG for transmit and a CG for receive. For DC or Tone Remote controlled stations, the CG Disable (monitor) function, controlled by DC or Tone Remote control signaling, may override the receiver CG or DCG decoding by un-muting the receiver and allowing all on-frequency activity to be monitored. When CG or DCG tones are used to key repeater stations, the transmitter is activated only when the proper CG or DCG tone is decoded, regardless of the CG Disable condition. On the System Module, setting the CG MONITOR switch in the UP position (LED indicator lit), causes the receiver to un-mute and operate in the carrier squelch mode. This has no affect on repeater stations using DC or DCG tones to signal a PTT request to the transmitter. The transmitter is activated only if the proper CG or DCG tone is present on the received signal. 5.6.2.2.1 Tone Channel Guard The industry standard Continuous Tone Coded Squelch System (CTCSS) or CG tones range from 67 Hz to 210.7 Hz. Extended CG tones above 210.7 Hz are available, but can cause some degradation in specifications. The System Module monitors the station’s receive demodulated audio output for a CG tone and signals the station when the proper CG tone is received. Once the proper receive CG tone has been detected, the System Module un-mutes the receive audio and causes other pre-programmed actions to occur. In addition, the System Module generates any TX CG tones programmed on a channel and routes the audio to the TX Synthesizer card to modulate the carrier. A 135-degree phase shift in the CG tone is also generated at the end of a transmission for 160 milliseconds after the transmitter is un-keyed (PTT button released) to initiate STE in the receiving station, if equipped with STE. 35 MM102558V1 R1A 5.6.2.2.2 Digital Channel Guard The System Module also encodes and decodes Digital Channel Guard (DCG) tones. There are 83 digital codes available. Any of the digital codes can be assigned to any transmit or receive channel. DCG functions much like CG however provides many more user codes. The encoding function provides continuous, repetitive digital word modulation to the transmitter. The decode function controls receiver muting to eliminate all calls that are not digitally coded with the assigned CG code. 5.6.2.3 TX Pot The TX Pot value is used to set the main transmitter deviation limit. There is a unique TX Pot setting for each channel. The value has a range of 0 (min) to 255 (max), with a software default of 71. 5.6.2.4 CG Pot The CG Pot value is used to set the main CG deviation level. There is a unique CG Pot setting for each channel. This value has a range of 0 (min) to 255 (max), with a software default of 69. 5.6.2.5 RF Simplex and Rpt The RF Simplex and Rpt features on the Channel Data screen allow the programmer to define whether the associated channel operates in full-duplex or Simplex. Setting RF Simplex to Yes will automatically cause the Rpt to be set to No and the channel operates in simplex mode. Setting RF Simplex to No and Rpt status to Yes defines the channel as full-duplex repeater operation. Setting both RF Simplex and Rpt status to No defines the station as full-duplex capable, 4-wire, nonrepeater channel. 5.6.2.6 PA Power Pot The RF Power Amplifier (PA) output power level may be set using the TQS3353 software programming tool. Control signaling occurs between the RF Power Amplifier and the T/R Shelf. Pre-programmed PA Power settings use this signaling to control the level of RF output power and manage PA alarm conditions. There is a unique PA Power Pot setting for each channel. Settings range from 0 to 99, with 99 corresponding to full power output. 5.6.3 Push-to-Talk Options The System Module allows individual programming of Repeater PTT, Remote PTT, Local PTT, External PTT and Morse Code ID PTT functions with regard to CCT and DODT signaling as well as CG Encode options. Each type PTT signal may be defined to allow or exclude CCT, DODT or CG Encode functions. 5.6.4 Other Potentiometer Settings Most of the MASTR III ADC station audio level settings are software programmable. Software programmable Pots are used for Line Out, Repeater Gain, Line In, DSP Cancel, DSP In, DSP Compressor, DSP Compressor Threshold and Squelch Pot. These settings are global (not assigned to any specific channel) and therefore apply to the overall station operation 5.6.5 Carrier Control Timer The MASTR III ADC station may be pre-programmed for a Carrier Control Timer (CCT). Programming of the CCT will prevent the station for transmitting long durations. Use of a CCT may be a regulatory requirement by some agencies, and a means to prevent unwanted transmissions in the event of system failures or accidental keying of remote controllers or terminal devices in repeater applications. 36 MM102558V1 R1A 5.6.6 Squelch Tail Elimination Squelch Tail Elimination (STE) eliminates the burst of squelch noise heard when the received carrier drops immediately and the CG circuit is still un-muted. When using STE, the transmitter remains keyed for a short duration when the PTT is released. When STE is enabled during CG tone signaling, STE directs the CG tone to be phase shifted by 135degrees. If the CG detector in the receiving station is equipped with STE, the detected phase shifted CG signal will cause the receiver to mute the audio path before the carrier ends. When STE is enabled during DCG signaling, STE directs the DCG tone circuit to encode a square wave when the PTT is un-keyed, which continues until the end of the carrier transmission. When detected by the receiving station, the square wave interrupts the DCG signal pattern and mutes the receive audio before the received carrier ends thus eliminating any burst of squelch noise. 5.6.7 Drop Out Delay Timer The Drop Out Delay Timer (DODT) clocks the time after a PTT un-keys till the carrier ends. When set, the transmitter remains keyed after all PTT signals are finished for the specified time duration. This timer may be set from 0 to 10 seconds, in 10 millisecond increments. 5.6.8 Control Shelf Options The System Module also provides programming for certain Control Shelf options. These options include Morse Code ID, Voting, Battery Alarm, Aux RX, Logic Standby, Intercom, RX IF Bandwidth and receiver channel scan. 5.6.8.1 Morse Code ID A Morse Code ID may be programmed into each channel defined in the personality. This feature may also be enabled or disabled on a per-channel basis. Up to twelve (12) consecutive characters from any of the standard 26 letters of the English alphabet, numbers 0 through 9 and the “ / ” forward slash bar may be entered as a part of a CW ID. No spaces may be programmed within the twelve consecutive characters. The Morse Code ID is sent at a rate of 20 words-per-minute and may be programmed for intervals of 5 to 30 minutes, defaulted to thirty minutes, with a wait time interval (pause time after CAS or line signal ends) of 0 to 10 seconds in 100 millisecond steps. The ID may be programmed to send either with or without Channel Guard encoding. 5.6.8.2 Battery Alarm During battery stand-by power conditions, the station power supply applies a battery standby signal to the T/R shelf backplane. The signal is passed to the System Module which generates a default 1200 Hz alert tone and adds it to the transmit audio. The 1200 Hz tone may also be sent down the wire line to any remote control unit in the system (see note). A battery stand-by condition will not force the station to key or send a PTT. Rather, over-the-air transmission of the alert tone occurs only when the station is keyed by normal operations. This prevents unnecessary battery drain caused by the high current requirement of the station during transmit. The repetition rate and on-time rate are programmable. The repetition rate sets the time from the beginning of a tone to the beginning of the next tone, and is programmable from 0 to 25 seconds in increments of 1 second. The on-time rate sets the duration of the tone burst, and is programmable from zero 0 to 1 second, in increments of 100 milliseconds. 37 MM102558V1 R1A For Battery Alarm tones to be passed down the wire line, it may be necessary to install R112 on the System Module. Refer to the System Module schematic for installation instructions. 5.6.8.3 Logic Standby When enabled, Logic Standby will restore certain station features in the event of a power failure or station reset. The features that will be restored are: CG Monitor, Remote PTT, Scan, Priority Scan, Aux Relay Settings, Morse Code ID, Main Receiver, 2nd Receiver, External PTT and Voice Guard. 5.6.8.4 Intercom When enabled, the intercom feature built into the T/R shelf programming may be set to define the specific combination of line audio, receiver audio and handset audio that is routed to the station speaker. This is a useful tool for the service technician and other on-site operations. After enabling the feature in software by selecting Yes, refer to the software Help screens for detailed programming configuration information. 5.6.8.5 Bandwidth The MASTR III ADC shelf is capable of transmitting and receiving signals modulated by two different bandwidths: 12.5 kHz and 25 kHz. This allows the station to meet regulatory and technical requirements of the many different digital and analog and channel spacing/frequency allocation schemes. 5.6.8.6 Receiver Channel Scan The station may be enabled to scan selected receiver frequencies. Once enabled, each channel programmed in the main programming screen may be added to a scan list by selecting Yes or No. The scan option may be configured for certain features using MASTR Station Editor (MSEDIT) programming software. Features such as Scan Enabled on Power-up, Priority Scan, Revert Scan, Search Rate and Hang Time are just a few configuration features available through MSEDIT. 5.6.8.7 Voting The MASTR III ADC station may be configured for voting operation. Voting is the practice of using a Voting Selector with satellite receivers to form a receiver voting system. The satellite receivers are located so that one or more of the receivers will receive a good quality signal from a Personal or Mobile two-way radio transmitting from anywhere in a specified operating area. Each receiver output is connected to a centrally located Voting Selector by an RF link, a Tone or a DC control line, or an E&M pair. The Voting Selector provides continuous voting for the satellite receivers and selects the receiver with the best audio quality. 5.6.9 Station Remote Control The System Module in the T/R Shelf can be remotely controlled by DC Remote control or Tone Remote control. DC Remote and Tone Remote control signals may allow a user to initiate a transmission, disable RX Channel Guard, listen to received audio, select between two operating channels, and select or deselect certain T/R Shelf functions. Configuration and operational features for Two-wire, Four-wire, DC Remote control and Tone Remote control signaling are described in the following sections. 38 MM102558V1 R1A 5.6.9.1 Two-Wire/Four-Wire Operation Two-wire describes a single pair of dedicated metallic wires in the form of discrete 600 ohm telephone wire provided by a customer, 600 ohm dry (quiet line only) telephone line provided by a telephone company, or the multiplexed equivalent provided by customer or telephone company owned equipment. This type of circuit will support the bi-directional transmission of audio signals in the nominal 300 to 3000 Hz frequency range. Switched or multiplexed circuits generally will not pass DC Remote control signaling. Support of DC control signals is available only with physical or metallic equivalent circuits and may not be available in some areas. Four-wire describes two pair of (usually) multiplexed dedicated telephone circuits with one pair going each way. Each pair will support uni-directional transmission of audio signals in the nominal 300 to 3000 Hz frequency range. One pair is usually designated as the SEND pair while the other is designated as the RECEIVE pair. DC signaling and control is usually not available. These circuits may be obtained for voice only or for voice and/or data applications. 5.6.9.2 DC Remote Control current signaling in a DC Remote Control system is achieved when a DC Remote Controller applies current levels on a wire pair having end-to-end DC continuity. The wire pair may be provided by the customer or a commercial wire line carrier, such as a telephone company. The overall circuit resistance of the wire line between the console controller and the station must not exceed the maximum loop resistance that the controller can support. The six control current levels recognized by the remote T/R Shelf are: -11 milliamperes -6 milliamperes -2.5 milliamperes 0 milliamperes +6 milliamperes +11 milliamperes Station functions which can be controlled by these control currents are: • Repeater Disable • Channel Guard Monitor • Transmit Frequency Selection • Receive Frequency Selection • Scan • Receiver Selection (Auxiliary Receiver stations) Please note that when leasing a wire line from a local wire line carrier, not all leased line services support DC control applications. Not all leased line services support DC control applications. Please check with your wire line carrier before attempting DC control on a leased line. 39 MM102558V1 R1A 5.6.9.3 Tone Remote In tone remote applications, the T/R Shelf uses the System Module and its onboard Digital Signal Processor (DSP) to interface with a Tone Remote control unit through a two-wire or four-wire phone line. A MASTR III ADC station may be programmed to allow Tone Remote control of the following functions: • Repeater Enable (disable) • Channel Guard Decode Enable (disable) • Channel Guard Monitor • Transmit Frequency Selection • Receive Frequency Selection • Scan • Receiver Selection (Auxiliary Receiver selection) • Auxiliary Output Enable (disable) (Auxiliary Control) Signaling from a Tone Remote control unit consists of a high level Secur-it tone, followed by the appropriate medium level function tone (as well as a hold tone if the transmitter is keyed). The tone control sequence is shown in Figure 5-3. The Secur-it tone is a +10 dB, 2175 Hz tone that is present for 125 milliseconds. The Secur-it tone is followed by a 40 millisecond, 0 dB Function tone. The Function tone can be followed by a 2175 Hz Hold tone at -20 dB level if PTT is selected. The Hold tone is present as long as the PTT is pressed. Figure 5-3: Tone Remote Control Signaling The frequency of the Function tone determines the function selected by a tone remote control unit. Function tones range from 1050 Hz to 2050 Hz, and are spaced 100 Hz apart. 40 MM102558V1 R1A Table 5-1: Typical* Tone Functionality for Tone Remote Control Signaling TONE (Hz) FUNCTION TONE (Hz) FUNCTION 2175 SECUR-IT / TX Hold 1550 Channel Guard Decode or Repeater Enable 2050 RX Channel Guard Disable (Reset by PTT) 1450 Channel Guard Decode OFF or Repeater Disable 1950 TX Freq. No. 1 1350 TX-Freq. No. 3 or Aux. Function 1 ON 1850 TX Freq. No. 2 1250 TX-Freq. No. 4 or Aux. Function 1 OFF 1750 TX Freq. No 1 or Receiver No. 1 1150 Repeater Enable** 1650 TX Freq. No 2 or Receiver No. 2 1050 Repeater Disable** or Scan Simultaneous Monitor The functionality listed for each tone is typical, however may differ for some installations. ** Repeater Enable and Repeater and disable are 1150 Hz and 1050 Hz only when Channel Guard ON/OFF is present. 5.6.10 Auxiliary Control Relay The MASTR III ADC T/R shelf may be equipped with up to two optional auxiliary relay kits, identified as K1 and K2. Assignment of control functions for each relay may be performed using MSEDIT Programming software. AUX1 relay (K1) and AUX2 relay (K2) each contain two Form-C contacts and operate under remote control. When AUX1 function is started, the system microprocessor sets signal RXF3/AUX1 to logic high which switches K1. When AUX2 function is started, the system microprocessor sets bit 4 of output register U106 high which switches K2. When the AUX functions are stopped, the control bits are toggled, and the relay coil drops out. Detailed installation instructions may be found in Installation Manual MM102554V1. 5.6.11 Squelch Operated Relay The MASTR III ADC T/R shelf may be equipped with an optional Squelch Operated Relay (SOR), identified as K3. The SOR (K3) contains four form "C" contacts and is rated for 2 amps at 20 VDC. The relay operates under control of signal RX_1_MUTE, which is derived from the Carrier Activated Squelch (CAS) signal. Detailed installation instructions may be found in Installation Manual MM102554V1. 5.6.12 Channel Guard Monitor When the CG Monitor function DC control current or tone is received from a remote control unit, the T/R Shelf does not require the correct CG before un-muting the receiver. This allows received audio to be passed down the line to a remote control unit regardless of CG content, allowing the remote operator to monitor all frequency activity prior to transmitting. For repeater stations, the correct CG tone(s) are still required to key the station in repeat mode. This function is automatically reset when a remote control unit keys the transmitter. 41 MM102558V1 R1A 5.6.13 System Module - Digital Signal Processing The System Module also employs a State-of-the-Art audio Digital Signal Processing (DSP). Audio DSP is used to improve audio clarity, provide consistent audio leveling and enhanced tone generation and decoding for more flexible and reliable control functions. The DSP provides line cancellation used during 4-wire mode to prevent unwanted signaling on the line, notch filtering during voted applications and line audio level processing employing compression and threshold settings. 42 MM102558V1 R1A MASTR III ADC STATION DESCRIPTION The MASTR III ADC base station may be equipped to operate in the VHF, UHF or 800 MHz band. The station equipment is designed to install into a 19 inch wide rack mount equipment cabinet or rack. The station can be equipped with a wide range of modules and accessories to meet a diverse range of system requirements including simplex, half duplex, duplex and transmit-only frequency operation. Modulation schemes include Frequency Modulated (FM) analog and digital modulation. Stations may be equipped as a single stand-alone unit or as a multiple station installation including antenna combining and multiplexing techniques. The basic set of MASTR III ADC base station equipment consists of the following: • MASTR III ADC T/R Shelf • RF Power Amplifier MASTR III ADC base stations are available with various combinations of the following equipment: 6.1 • Station Power Supply • Antenna Switch • TX/RX Antenna Duplexer • TX Combiners and RX Multicouplers • 37” and 83” Cabinets, and 86” Open Rack MASTR III ADVANCED DIGITAL CAPABLE T/R SHELF The ADC Transmitter/Receiver (T/R) Shelf provides housing and interconnection for the RF and control modules. Figure 6-1 shows a typical MASTR III ADC T/R shelf with the basic set of modules required for basic Conventional FM transmit and receive applications. Additional modules are available for TX Data requirements, RX audio multi-path filtering, and Conventional P25 applications. The T/R Shelf is comprised of a 19 inch rack mountable enclosure, an Interface board and a Backplane board to interconnect each module. The T/R shelf may be populated with various TX, RX, power and control modules. The function of each module is briefly described in the following sections. The plug-in modules available for Conventional applications include: • TX Synthesizer Module • System Module • RX Synthesizer Module • Adaptive Multi-Path Filter Module • RX Front End Module • Data Module • RX IF Module • DSP Module • Power Module (DC) 43 MM102558V1 R1A Transmit Synthesizer Receiver Front End Receiver Synthesizer System Module Power Module Receiver IF Figure 6-1: Advanced Digital Capable T/R Shelf (Equipped for Conventional FM) 6.1.1 Interface Board The Interface Board 19D902975, shown in Figure 6-2, is mounted in the top of the ADC T/R shelf and provides the interface between the System Module and the RF Modules, and performs the following functions: • Control Interface from System Module to RF Modules. • Telephone line interface with current level detection for remote control. • Audio PA for local speaker. • Transmitter power output level and control. • Manual adjustment with front panel access of receiver squelch and local speaker volume. • LED indication of PA Alarm. • Various connectors including RS232 programming port and Mic/Handset port. • Alarm and monitor junctions of PA output power for MASTR III applications. 6.1.2 Backplane The Backplane Board CB101126V1, shown in Figure 6-2, is used to interconnect power, low level audio, IF and data signaling between the MASTR III RF, Power and System Modules. 44 MM102558V1 R1A Backplane Interface Board Figure 6-2: MASTR III ADC T/R Shelf Backplane and Interface Board 6.1.2.1 Transmitter Synthesizer Module The Transmitter Synthesizer Module (TX SYN) model EA101685, shown in Figure 6-3, provides the RF excitation for the input of the base station RF Power Amplifier. The output of the TX synthesizer is a Frequency-Modulated (FM) signal and derives its reference oscillator signal from either the Receiver Synthesizer Module or Data Module in Transmit-Only base stations. Figure 6-3: Transmitter Synthesizer Module 6.1.2.2 Receiver Synthesizer Module The Receiver Synthesizer (RX SYN) module EA101684, shown in Figure 6-4, generates a Phase Locked Loop (PLL) Local Oscillator (LO) signal used by the Receiver Front End Module in the ADC T/R Shelf. The Synthesizer Module follows operational and frequency determining instructions from the System Module to select between an external or internal reference oscillator which provides a highly stable reference for the PLL to operate. The Receiver Synthesizer Module also provides the selected reference oscillator signal to the Transmitter Synthesizer Module. Figure 6-4: Receiver Synthesizer Module 6.1.2.3 Receiver Front End Module The Receiver Front End (RxFE) Module 19D902782, shown in Figure 6-5, provides Front End band pass tuning capable of passing the desired receiver frequency while providing first L.O. image rejection and L.O. signal isolation at the antenna port. The RxFE also mixes the RF signal from the band pass circuit with the Receiver Synthesizer signal to create the First Intermediate Frequency (IF) signal, 21.4 MHz for VHF and UHF systems, and 70.2 MHz for 800 MHz systems. Finally, the First IF signal is passed to the receiver IF module. Figure 6-5: Receiver Front End Module 45 MM102558V1 R1A 6.1.2.4 Receiver IF Module The Receiver IF (RX IF) module models EA101401V1 (21.4 MHz for VHF and UHF stations) and EA101794V1 (70.2 MHz for 800 MHz stations), shown in Figure 6-6, provides IF filtering, amplification, and demodulation of the IF signal. Output signals from the IF modules include a balanced 455 kHz IF output for data applications and a demodulated audio output for analog audio applications. The IF Module also provides AGC for the 455 kHz IF signal and includes the receiver squelch circuitry. Figure 6-6: Receiver IF Module 6.1.2.5 System Module The System Module 19D902590G6, shown in Figure 6-7, uses programmable microcomputer technology to control the base station's transmitter, receiver, and audio processor. This module contains a Digital Signal Processor (DSP) used for audio processing, tone generation and detection. The System module can be programmed for up to twelve (12) channel operation during local control or programmed for remote control applications. DC remote control features can control up to two (2) transmit and receive frequencies, while Tone remote control can control up to four transmit and receive frequencies. Options provided by the Control Section include a transmitter Drop-Out Delay (DOD) timer, Carrier Control Timer (CCT), Channel Guard (CG), and Squelch Operated Relay output (SOR). The CCT is programmable from zero to 10 minutes. The DOD is programmable from zero to 10 seconds. Additional station options include: 46 • Battery alarm tone • Type 90 or DTMF tone decoding • 2/4 wire audio • Morse code station identification • Auxiliary control Figure 6-7: System Module MM102558V1 R1A 6.1.2.6 Data Module Data Module 19D904558, shown in Figure 6-8, allows the MASTR® III Base Station to transmit Non Return to Zero (NRZ) data such as those produced by paging systems. The Data Module accepts data with rates up to 9600 baud within a range of -25V to +25V. The Data Module produces two corresponding outputs; a modulated 12.8 MHz reference signal to drive the Reference Input of the Transmit Synthesizer, and filtered audio data that modulates the audio input of the Transmit Synthesizer. Together these modulation sources produce a clean data pattern resulting in reliable data transmissions. Figure 6-8: Data Module 6.1.2.7 AMPF Module AMPF Module KRG 101 56/1, shown in Figure 6-9, is a self-contained DSP-based plug-in module capable of filtering audible low frequency pops out of the base station’s received audio signal. The module executes a proprietary DSP algorithm that reduces the audible pops primarily caused by the reception of reflected or multi-path RF signals because of an affect known as Rayleigh distribution or Rayleigh fading. Figure 6-9: AMPF Module 6.1.2.8 Power Module The Power Module 19D902589G2, shown in Figure 6-10, provides power to the T/R shelf and modules. It contains switching regulators for the +5V, +12V, and -12V DC supplies. The output of the +12V and 12V supplies are further regulated to provide +5V and -5V required by the analog components. Figure 6-10: Power Module 6.1.2.9 DSP Module The DSP Module EA101800V1, shown in Figure 6-11, The DSP Module provides the necessary processing to generate and decipher the outbound and inbound P25 signaling. The DSP module extracts P25 intelligence from the 455 kHz Receiver IF data output and forms it into two outputs, the High Speed Data (HSD) output and a serial output. The HSD output is passed to the System Module for re-transmission and the serial data is routed to a Station SitePro for conversion to IP packets or other formats for remote applications. Figure 6-11: DSP Module The DSP Module also encodes incoming data from the Station SitePro and analog inputs into P25 data and passes it to the System Module. The DSP Module allows the MASTR III P25 station to support the TIA 102 P25 Clear Air interface (CAI) protocol. 47 MM102558V1 R1A 6.2 STATION EQUIPMENT 6.2.1 Station Power Supply The MASTR III ADC station is available with either of two models switching power supply. The PS103010 (120 VAC input), shown in Figure 6-12, and the PS24043-0001 (240 VAC input), shown in Figure 6-13, are Multi-Output; AC to DC Switching Power Supplies housed in a metal chassis with builtin dual cooling fans. The supplies replace the previous model 19A149979 series 120V and 240V power supplies. Both the PS103010 and PS24043-0001 switching power supplies are 600 Watt continuous duty power supply with two independent voltage outputs for full station operation, and includes a built-in battery back-up system. A 27.2 VDC output at 15 Amperes provides power to the RF Power Amplifier while a 13.6 VDC output at 6 Amperes provides power to the MASTR III ADC system (T/R) shelf. The battery back-up circuit includes a built-in battery charging circuit to maintain maximum battery performance. The supply incorporates features for over-voltage and over-current protection, 24V status signaling, and a forced-air cooling system for optimal system performance. Figure 6-12: 120 VAC Switching Power Supply Figure 6-13: 240 VAC Switching Power Supply 6.2.2 DC Power Distribution Panel A DC Power Distribution panel is available for the MASTR III ADC station. This DC panel provides a high current 24 VDC input connection, and a low current 12 VDC input connection from external DC power sources. The panel includes safety fuses for each power source and the necessary distribution points to power station equipment. 6.2.3 RF Power Amplifier Assembly The RF Power Amplifier (PA) Assembly EA101292, shown in Figure 6-14, amplifies the exciter output to rated output power level. This module contains a power module, amplifier drivers and power control circuitry required for power amplification. The Power Amplifier Assembly is a continuous duty, solid state, wide-band RF power amplifier. Its main function is to amplify the 10 mW FM signal from the Transmitter Synthesizer to the rated RF output at the antenna port. The output of the Power Amplifier Assembly is typically 110 Watts for VHF (adjustable from 10 to 110 Watts) and 100 Watts for UHF and 800 MHz (adjustable from 10 to 100 Watts) as measured at the PA output port. 48 MM102558V1 R1A Figure 6-14: RF Power Amplifier 6.2.4 RF Antenna Switch Assembly An RF Antenna Switch assembly, shown in Figure 6-15 is available for conventional MASTR III ADC stations operating in the simplex or halfduplex base station mode. The Antenna Switch is available with or without mounting hardware and cabling. Mounting hardware options are available for mounting the Antenna Switch either directly to the RF PA assembly or as a 19” rail mounted device. Figure 6-15: Antenna Switch 6.2.5 Cabinet Enclosures and Open Rack Assembly MASTR III ADC station equipment is typically installed in a steel cabinet or rack, however may be ordered without a cabinet or rack. Cabinet enclosures include front and rear doors for full station access. Also available is an indoor open rack and a weatherproof outdoor cabinet. The following list defines the available cabinet sizes, styles, and number of MASTR III ADC stations that can be installed into each type of cabinet or rack, dependent upon the hardware options installed in conjunction with each station: • 37" Indoor Cabinet (1 station per cabinet) • 45” Weatherproof Outdoor Cabinet (1 station per cabinet) • 69” Indoor Cabinet (1-4 stations per cabinet) • 83" Cabinet (1-5 stations per cabinet) • 86" Open Rack (1-5 stations per rack) 49 M/A-COM Wireless Systems 221 Jefferson Ridge Parkway Lynchburg, Virginia 24501 (Outside USA, 434-385-2400) Toll Free 800-528-7711 www.macom-wireless.com Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Company : M/A-COM Source Modified : D:20060726145019 Create Date : 2006:07:26 11:05:32-04:00 Creator Tool : Acrobat PDFMaker 7.0.5 for Word Modify Date : 2006:07:26 11:13:03-04:00 Metadata Date : 2006:07:26 11:13:03-04:00 Document ID : uuid:fc8cfada-683d-4e97-be22-b3afe9788438 Instance ID : uuid:de45428c-8eec-49e9-a4a8-3792fe44bdd6 Version ID : 32 Format : application/pdf Title : MM102558V1, R1A, MASTR III Conventional ADC & P25 Conventional Base Stations Creator : M/A-COM, Inc. Description : Overview Manual Subject : Headline : Overview Manual Page Count : 50 Page Layout : SinglePage Author : M/A-COM, Inc.EXIF Metadata provided by EXIF.tools