Resolution RE101X Security Transmitter, 319.5MHz User Manual RE101 GE Compat DWS Instructions

Resolution Products, Inc. Security Transmitter, 319.5MHz RE101 GE Compat DWS Instructions

User Manual

Download: Resolution RE101X Security Transmitter, 319.5MHz User Manual RE101 GE Compat DWS Instructions
Mirror Download [FCC.gov]Resolution RE101X Security Transmitter, 319.5MHz User Manual RE101 GE Compat DWS Instructions
Document ID1499024
Application IDf0cGXSh7foiSGV8EQ9fuBQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.34kB (266796 bits)
Date Submitted2011-07-12 00:00:00
Date Available2011-07-12 00:00:00
Creation Date2011-06-29 12:46:59
Producing SoftwareGPL Ghostscript 8.64
Document Lastmod2011-06-29 12:46:59
Document TitleRE101_GE-Compat_DWS_Instructions
Document CreatorPDFCreator Version 0.9.8
Document Author: bseemann

Specifications
Magnet trip distance:
Mounting hardware:
Replacement Battery:
Temperature Range:
Housing dimensions:
Wireless
Security
Solutions
RE101 GE-Compatible Standard Door / Window
1 inch nominal
# 4 or #6 screws
CR123A 1550mAH
0F to 120F
3.3x1.4x1.1 inches
Specifications subject to change without notice.
Features
• For sensing things that open or separate.
• Magnet and Internal reed switch operation.
• 2 supplemental hardwire zones.
o GE-compatible version reports 2nd zone to 2nd ID.
• Cover tamper.
• Strong, reliable RF signal.
• 10-15 year battery life on CR123A battery.
• Low Battery indication.
Internal Picture
2nd ID
Inner Terminal Zone
Key Instructions
• Battery “+” faces towards spring.
• No end-of-line resistors on hardwire zones.
• Panels assume hardwire zone alarm is state in which contact was enrolled.
• Center hardwire terminal is common.
• Reed switch and terminal closest to (outer) it are 1st ID
• Inner terminal is 2nd ID.
• Enrolling:
 1st ID: Reed switch and outer terminal zone are enrolled by
tamper switch.
 2nd ID: Inner terminal zone is enrolled by holding down
tamper while installing battery.
Outer Terminal Zone
Magnetic Reed Switch
Operation
• Magnetic and 1st (outer) hardwire zone (1st ID)
Alarm, when…
… magnet is pulled away from reed switch.
… contact changes to alarm.
Tamper, when cover is opened.
Supervisories, every hour.
• 2nd (inner) hardwire zone (2nd ID)
Alarm: when contact changes to alarm condition.
Tamper: none.
Supervisory: every hour.
RE101_GE-Compat_DWS_Instructions.doc Page 1 of 3
www.ResolutionProducts.com
Center Common Terminal
1st ID
29-Jun-11
RE101_GE-Compat_DWS_Instructions.doc Page 2 of 3
www.ResolutionProducts.com
29-Jun-11
Notices
“GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell
International Inc., and Tyco Safety Products Canada LTD, respectively.
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell
systems. However, no Resolution product is produced by, endorsed by, nor is officially
associated with GE, Honeywell or DSC. Resolution recommends verifying proper enrollment
and operation, per control panel installation instructions, at installation.
Warranty
Resolution Products, Inc. will replace products that are defective in their first year.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could
void the user's authority to operate this equipment.
FCC ID: U5X-RE101X
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may
cause undesired operation of the device.
Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence.
Son fonctionnement est soumis aux deux conditions suivantes:
1. Ce dispositif ne peut causer des interférences, et
2. Ce dispositif doit accepter toute interférence, y compris les interférences
qui peuvent causer un mauvais fonctionnement du dispositif.
IC: 8310A-RE101X
RE101_GE-Compat_DWS_Instructions.doc Page 3 of 3
www.ResolutionProducts.com
29-Jun-11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : 4e4e8540-a4d3-11e0-0000-28e5a40385b7
Producer                        : GPL Ghostscript 8.64
Keywords                        : ()
Modify Date                     : 2011:06:29 12:46:59-05:00
Create Date                     : 2011:06:29 12:46:59-05:00
Creator Tool                    : \376\377\000P\000D\000F\000C\000r\000e\000a\000t\000o\000r\000 \000V\000e\000r\000s\000i\000o\000n\000 \0000\000.\0009\000.\0008
Document ID                     : 4e4e8540-a4d3-11e0-0000-28e5a40385b7
Format                          : application/pdf
Title                           : \376\377\000R\000E\0001\0000\0001\000_\000G\000E\000-\000C\000o\000m\000p\000a\000t\000_\000D\000W\000S\000_\000I\000n\000s\000t\000r\000u\000c\000t\000i\000o\000n\000s
Creator                         : \376\377\000b\000s\000e\000e\000m\000a\000n\000n
Description                     : ()
Author                          : bseemann
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U5X-RE101X