Risco WT71V2 Door / Window Contact Detector User Manual NOVA T71
Risco Ltd. Door / Window Contact Detector NOVA T71
Risco >
Manual
Italiano 1. DESCRIZIONE Il Nova 71 è un trasmettitore universale con supervisione che può essere connesso ai contatti magnetici (protezione di finestre o porte) o ad altri sensori. Funziona assieme ad altri ricevitori programmabili della Rokonet ed è alimentato da una batteria di riserva al litio a 3V. HOLDON SLOW NO. OPEN - (OUT) TB1 USED AND (4) MAGNET+N.C. MAGNET+N.O. INPUT (TB1) INPUT (TB1) HOLDON SLOW N.C. OPEN - (OUT) TB1 USED AND (3) N.C. INPUT (TB1) HOLDON SLOW N.C. CLOSED - (IN) TB1 USED TB1 ONLY N.O. INPUT (TB1) HOLDON SLOW NO. CLOSED - (IN) TB1 USED TB1 ONLY (TB1) is closed the unit will send restore. Otherwise the unit is in open (alarm) state. 4. Only if the magnet is closed and the external input (TB1) is open the unit will send restore. Otherwise the unit is in open (alarm) state. Français 1. DESCRIPTION GENERALE Le NOVA 71 est un émetteur universel supervisé qui peut être connecté à des contacts magnétiques pour la protection des portes ou fenêtres, ou à d'autres capteurs. Alimenté par une pile lithium de 3 volts, il fonctionne avec les récepteurs programmables de Rokonet. CARACTERISTIQUES DU NOVA 71 ● Portée de 300 mètres en champ libre ● Adressage automatique (choisit un code parmi 16 millions pré-enregistrés en usine, donc pas de micro-interrupteur). ● Gestion par microprocesseur ● Faible consommation de la pile ● Entièrement supervisé ● Vitesse de détection modulable Rapide - pour les détecteurs de chocs Lente - pour les contacts magnétiques, etc... Entrées modulables (NF ou NO) ● 2. MODES DE FONCTIONNEMENT NORMAL : Le NOVA 71 transmet un message alarme quand il y a déclenchement, et un message "restorable" pour la remise à zéro. Un seul message alarme est transmis toutes les 2.5 minutes (temps d'inhibition). Note : D'autres messages restorable (de mise à zéro) peuvent être effectués en ouvrant et refermant les entrées. ADRESSAGE (Write) : L'adressage sera transmis en appuyant sur l'autoprotection pendant 3 secondes. (voir ci-après) Note : Le NOVA 71 envoie un message de supervision toutes les 65 minutes indiquant ainsi l'état des sorties et l'autonomie de la pile. Note : A l'installation de la pile ou à son remplacement, effectuez une vérification de communication avec le récepteur pour vérifier le bon fonctionnement. INDICATION DE LA LED : Après chaque détection, la LED s'allume un moment. Lorsque les piles sont usées, la LED clignotera 3 fois pendant chaque transmission d'alarme. Español 1. DESCRIPCION GENERAL El NOVA 71 es un transmisor supervisado para usos generales, que puede ser conectado a contactos magnéticos (protección de puertas y ventanas) o a otros sensores. Opera conjuntamente con los receptores programables de Rokonet y es alimentado por una batería estándar de litio de 3 V. CARACTERISTICAS DEL NOVA 71 ● Radio de acción de hasta 300m (1000 pies) al aire libre ● Utiliza uno de entre más de 16 millones de posibles códigos de dirección pseudo aleatorios preseleccionados ● Diseño microprocesado ● Prolongada vida útil de batería ● Totalmente supervisado ● Tiempo de reacción selectivo: Rápido - para sensores de impacto Lento - para interruptores magnéticos, etc. seleccionable - N.C. o N.O. ● Entrada 2. MODOS DE OPERACION NORMAL: El NOVA 71 transmite un MENSAJE DE ALARMA cuando es disparado; cuando es restaurado, transmite un MENSAJE DE RESTAURACION. Un solo MENSAJE DE ALARMA es transmitido durante un intervalo de 2.5 minutos. Nota: Un mensaje de restauración extra puede ser generado reabriendo y cerrando las entradas. WRITE: Un mensaje WRITE será transmitido al presionar el botón de tamper por lo menos durante 3 segundos. Nota: La unidad envía un mensaje de supervisión cada 65 minutos, para indicar el estado de la entrada y la condición de la batería. INDICACIONES DEL LED Inmediatamente después de cada detección, el LED se enciende momentáneamente. Ante una condición de Batería Baja - el LED parpadeará 3 veces durante cada transmisión. 3. COLOCACION DE LOS PUENTES Deutsch 1.D ALLGEMEINE BESCHREIBUNG Der NOVA 71 ist ein überwachter Universal - Sender, an dem Magnetkontakte (Tür/Fensterüberwachung) oder andere Sensoren angeschlossen werden kann. Er arbeitet zusammen mit den programmierbaren Empfängern von Rokonet und wird über eine 3 V Lithium - Batterie versorgt. NOVA 71 LEISTUNGSMERKMALE ● Reichweite bis zu 300 m (Freiland). ● Verwendet eine von mehr als 16 Mio. pseudozufällig gewählten Code-Adressen für das Setup (keine DIP-Schalter). ● Mikroprozessor - Design. ● Verlängerte Batterielebensdauer. ● Komplett überwacht (mit NOVA II+IV). ● Wählbare Ansprechzeit: Schnell - für Erschütterungsmelder Langsam - für Magnetkontakte, etc. Wählbarer Eingang - N.C. oder N.O. ● 2. BETRIEBSARTEN NORMAL - MODUS: Wenn der NOVA 71 ausgelöst wird, sendet er eine ALARMMELDUNG, bei der RÜCKSTELLUNG sendet er nur eine RÜCKSTELLMELDUNG. Nur eine ALARM - MELDUNG wird innerhalb eines 2,5 Min.-Zeitfensters übertragen (BatterieSparschaltung). Eine Extra-Rückstellmeldung kann durch erneutes öffnen und schließen der Eingänge aktiviert werden (Falls nötig). PROGRAMMIER - MODUS: Eine Adressenmeldung wird übertragen wenn man den Deckelkontakt für mind. 3 Sek. gedrückt hält. Hinweis: Das Gerät sendet alle 65 Minuten eine Überwachungsmeldung, die den Status des Eingangs (Offen/Geschlossen) und den Batteriezustand beinhaltet. Hinweis: Nach der Installation oder dem Austausch der Batterie führen Sie einen Kommunikationstest mit dem NOVA-Empfänqer durch, um eine einwandfreie Funktion zu gewährleisten. LED - ANZEIGE Nach jeder Detektion steht die LED kurz an. Bei schwacher Batterie, blinkt die LED dreimal während jeder Alarm- oder Rückstellübertragung. APPLICAZION/ ITEM SOLO CONTATTO MAGNETICO INTERNO J1 (1) HOLD-ON J2 (2) SLOW J3 NO. J4 APERTO (ESTRATTO) TBI LIBERO LOGICA DEL CONTATTO SOLO CONTATTO INTERNO & INGRESSO MAGNETICO ESTERNO TB1 INTERNO 1. HOLD-ON abilita un tempo di blocco trasmissioni di 2.5 minuti dopo una segnalazione (e relativo ripristino), in HOLDOFF il blocco trasmissioni non attivo per cui il trasmettitore trasmette sempre ogni variazione di stato. 2. Per usare una risposta veloce del circuito per i rivelatori inerziali, selezionare FAST (JP2). CONTATTO MAGNETICO INT. + INGRESSO ESTERNO N.C. (TB1) HOLD-ON SLOW N.C APERTO (ESTRATTO) TB1 USATO LOGICA AND (3) HOLD-ON SLOW N.C CHIUSO(INSERITO) TB1 USATO SOLO INGRESSO ESTERNO TB1 INGRESSO ESTERNO N.C. (TB1) HOLD-ON SLOW NO. CHIUSO (INSERITO) TB1 USATO SOLO INGRESSO ESTERNO TB1 INGRESSO ESTERNO N.O. (TB1) 3. Solo se il contatto magnetico interno chiuso e l’ingresso esterno (TB1) chiuso l’unita trasmette il segnale di ripristino. In caso contrario l’unit in stato "aperto" (allarme). 4. Solo se il contatto magnetico interno chiuso e l’ingresso esterno (TB1) aperto l’unit trasmette il segnale di ripristino In caso contrario l’unit in stato "aperto" (allarme). CONTATTO MAGNETICO INT. + INGRESSO ESTERNO N.O. (TB1) HOLD-ON SLOW NO. APERTO (ESTRATTO) TB1 USATO LOGICA AND (4) HOLD (J1) ON - "Tiempo Muerto" de 2.5 m entre detecciones de alarma (mensajes de restauración serán enviados inmediatamente al detectar la condición). OFF - No hay "Tiempo Muerto" entre detecciones de alarmas (la unidad transmitirá después de cada detección). RESPONSE TIME (J2): FAST - 10 ms (para operación con sensores de impacto). SLOW - 500 ms (para operación con contactos magnéticos, etc.). EXTERNAL SENSOR MODE (J3) (MODO DEL SENSOR EXTERNO): NC Normalmente Cerrado. NO Normalmente Abierto. INTERNAL REED SWITCH (J4) (INTERRUPTOR DE LENGÜETA INTERNO): IN Inutilizado. OUT Utilizado. S2 INPUT (+) HOLDOFF FAST NO LED1 J1 ANT1 © ROKONET 1999 BATTERY HOLDON SLOW NC S1 J4 ITALY ROKONET ELECTRONICS S.R.L. Via Mola, 39 20156 Milano Tel: (39) 023 925 354 Fax: (39) 023 925 131 E-Mail: info@rokonet.it J2 ISRAEL ROKONET Electronics Ltd. 14 Hachoma St. 75655 Rishon Letzion, Israel Tel: (972) 3 9616555 Fax. (972) 3 9616584 E-mail: info@rokonet.co.il BRAZIL ROKONET BRAZIL Avenida Das Americas, 500 Bloco 20 Loja 126 Barra Da Tijuca - Cep: 22640-020 Rio De Janeiro Tel: (55)-21-2496.3544 Fax: (55)-21-2496.3547 E-Mail: rokonet-brasil@uol.com.br 4/02 EMANT+N.C EMANT+NO. N.C. INFORMATION INFORMATION INFORMATION (TB1) (TB1) (TB1) ET (3) TB1 SEULEMENT 5INT71 D NO. Information (TB1) TB1 SEULEMENT exterieur (TB1) est ferme l‘unite envoira un eregistrement. Si non l‘unite restera ouverte (alarm). 4. Seulement si l‘emant est ferme, est l‘information exterieur (TB1) est ouvert l‘unite envoaira un eregistrement. Si non l‘unite restera ouverte (alarm). ET (4) HOLDON HOLDON HOLDON HOLDON HOLDON LENTEMENT LENTEMENT LENTEMENT LENTEMENT LENTEMENT N.C. N.C. NO. NO. NO. OUVERT-(EXTERIEUR) OUVERT-(EXTERIEUR) OUVERT-(EXTERIEUR) FERME- (INTERIEUR) FERME- (INTERIEUR) UTILISATION TB1 UTILISATION TB1 Utilisation TB1 Utilisation TB1 LIBREMENT EMANT SEULEMENT Der NOVA 71 hat vier Steckbrücken: APPLICATION J1 (1) J3 J2 (2) J4 TB1 EMANT SEULEMENT 1. Holdon - une pause de 2.5 minutes, en Holdoff il n’y a pas de perde de temps. 2. Pour avoir une reponse rapide shock sensor utiliser FAST (JP2) 3. Seulement si l‘emant est ferme, est l‘information LOGIC (EMANT & TB1) © 2002 Rokonet Electronics Ltd HOLD ( J1 ) : ON - 2,5 Minuten Wartezeit zwischen den Alarmdetektionen, um die Lebensdauer der Batterie zu verlängern. OFF - Keine Wartezeit zwischen den Alarmdetektionen (das Gerät sendet nach†jeder Detektion). ANSPRECHZEIT ( J2 ) : SCHNELL: 10 ms (für Erschütterungsmelder) LANGSAM: 500 ms (für Magnetkontakte, etc.) EXTERN-MELDER EINGANG ( J3 ) : NC - Normal geschlossen NO - Normal geöffnet EINGEBAUTER REED - KONTAKT ( J4 ) : IN - deaktiviert OUT - aktiviert NOVA 71 NOVA 71 transmitter Transmitter http://www.rokonet.com USA ROKONET IND. U.S.A. INC. 5 Westchester Plaza Elmsford, NY 10523 Tel: (914) 592 1068 Fax: (914) 592 1271 E-Mail: sales@rokonetusa.com UK ROKONET UK LTD. 4 & 5 West Court, Saxon Business Park Hanbury Road, Stoke Prior Bromsgrove Tel: (44) 1527 576765 Fax: (44) 1527 576816 E-Mail: info@rokonet.co.uk J3 Le NOVA 71 possède quatre cavaliers : MAINTENU (J1) ON: 2.5 minutes d'inhibition entre les détections d'alarme (les messages de remise à zéro seront envoyés immédiatement après que la condition soit détectée.) OFF : Pas d'inhibition entre les détections d'alarme (le NOVA 71 émet après chaque détection). TEMPS DE RÉPONSE (J2) Fast (rapide) - 10ms (fonctionnement avec détecteur de chocs) Slow (lent) - 500ms (fonctionnement avec les contacts magnétiques, etc...) MODE DU CAPTEUR EXTRENE (J3) NC - Normalement fermé NO - Normalement ouvert INTERNAL REED SWITCH (J4) IN - Activé OUT - Désactivé 3. STECKBRÜCKEN ANT2 POUR UNE INSTALLATION RAPIDE: JUMPER INSTALLATION POUR CAHQUE APPLICATION El Nova 71 posee cuatro puentes: INSTALLAZIONE VELOCE: PREDISPOSIZIONE PONTICELLI IN FUNZIONE DELL’APPLICAZIONE 3. POSITION DES CAVALIERS R11 English 1. GENERAL DESCRIPTION The NOVA 71 is a supervised general purpose transmitter that can be connected to magnetic contacts (door/window protection) or to other sensors. It operates together with Rokonet's programmable receivers and is powered by a standard 3-volt lithium battery. ● 2. FUNZIONAMENTO 3. SETTARE I PONTICELLI Il Nova 71 è dotato di 4 ponticelli: J1: ON: 2.5m di attesa tra le rilevazioni di allarmi (messaggi di ripristino saranno inviati immediatamente dopo ogni rilevazione). OFF: Nessun tempo di attesa tra le rilevazioni di allarme (il dispositivo trasmette dopo ogni rilevazione). TEMPO DI RISPOSTA (J2) RAPIDO: 10 millisecondi (quando opera con i sensori) LENTO: 500 millisecondi (quando opera con i contatti magnetici) SENSORE ESTERNO (J3) NC: Normalmente chiuso NO: Normalmente aperto CONTATTO REED (J4) IN: Disattivato OUT: Attivato LED: Dopo ogni rilevazione di allarme, il LED si accende momentaneamente. Se la batteria è scarica, il LED lampeggerà per 3 volte durante ogni trasmissione. MESSAGGIO: Un messaggio WRITE sarà trasmesso se il tasto del Tamper viene premuto per almeno 3 secondi. Nota: Il dispositivo invia un messaggio di supervisione ogni 65 minuti, per indicare lo stato d'ingresso e la condizione della batteria. Nota: Quando installate o sostituite la batteria, effettuate un controllo della comunicazione con il ricevitore per verificare il buon funzionamento del dispositivo. NORMALE: Il Nova 71 trasmette un MESSAGGIO di Allarme in condizione di allarme e trasmette un MESSAGGIO di Ripristino quando ritorna in funzione normale. Solamente un Messaggio allarme viene trasmesso durante il tempo d'intervallo da 2 a 3 minuti. Nota: Ulteriori messaggi di ripristino possono essere attivati aprendo e selezionando gli ingressi. Caratterisitiche del Nova 71 ● è dotato di una portata sino a 300 m ● Utilizza un indirizzo tra più di 16 milioni di indirizzi preprogrammati... (nessun Dip Switch) ● Microprocessore ● Batteria a lunga durata ● Completamente supervisionato ● Tempo di risposta selezionabile Rapido - per sensori d'urto Lento - per contatti magnetici Ingresso selezionabile - N.C o N.O NOVA 71 FEATURES ● Operates up to 1000 FT. (300m) range (outdoor) ● Uses one of more than 16 million pseudo-randomly selected preset code addresses for setup (no DIP switches). ● Microprocessor design. ● Extended battery life. ● Fully supervised. ● Selective response time: Fast - for shock sensors Slow - for magnetic switches, etc. Selective input - N.C. or N.O. ● 2. OPERATIONAL MODES NORMAL: The NOVA 71 transmits an ALARM MESSAGE when it is triggered; when restored, it transmits a RESTORAL MESSAGE. Only one ALARM MESSAGE is transmitted in any 2.5 minutes time slot. Note: Extra restoral message can be generated by reopening and closing the inputs. WRITE: A Write message will be transmitted by pressing the tamper button for at least 3 seconds. Note: The unit sends a supervisory message every 65 minutes indicating the input state and battery condition. Note: At installation or replacement, perform a Communication Check with the receiver to verify proper operation. LED INDICATION After each detection, the LED turns ON momentarily. On Low Battery condition - the LED will blink 3 times during each transmission. 3. JUMPER SETTINGS The Nova 71 has four jumpers: HOLD (J1): ON - 2.5 m Dead Time between alarm detections (restoral messages will be sent immediately after the condition is detected). OFF - No Dead Time between alarm detections (the unit transmits after each detection). RESPONSE TIME (J2): FAST - 10 ms (for operation with shock sensor). SLOW - 500 ms (for operation with magnetic contacts etc.). EXTERNAL SENSOR MODE (J3): NC Normally Closed. NO Normally Open. INTERNAL REED SWITCH (J4): IN Disabled. OUT Enabled. HOLDON SLOW NO. OPEN - (OUT) FREE MAGNET ONLY MAGNET ONLY F O R Q U I C K I N S T A L L A T I O N : JUMPER SETTING PER APPLICATION APPLICATION /ITEM J1 (1) J2 (2) J3 J4 TB1 LOGOC (MAGNET & TB1) 1. HOLDON means 2.5 minutes dead time, in HOLDOFF there is no dead time. 2. In case of using fast respond shock sensor, choose FAST (JP2). 3. Only if the magnet is closed and the external input B1 English 4. FRONT COVER REMOVAL (fig. 1). 5. TRANSMITTER/RECEIVER COMMUNICATION SETUP The NOVA 71 must identify itself to the system's receiver by writing its coded message into the receiver's address memory. This is accomplished by performing the following steps: a. Set the receiver to Write Mode. b. Remove the battery from the insulation material (fig. 2). Send a Write message pressing the tamper button for at least 3 seconds. Verify that NOVA 71 has been identified by the receiver. c. Set the receiver to Normal Mode. Note: if for any reason it is necessary to re-send a write message, press the tamper button for at least 3 seconds. 6. SELECTION OF INSTALLATION LOCATION a. Select a location best suited for communication quality and near the intended wired detector (for switched sensor). Place the unit at the highest possible position. b. Temporarily attach the unit to this point using two sided adhesive tape. c. Generate an Alarm signal (by momentarily opening or closing the input terminals) and verify that the receiver has received the signal. If the alarm signal is not detected, reposition the NOVA 71 and try again. Note: For best results when using NOVA II, set the receiver in the Communication Check Mode, and upon reception and verification, return it to the Normal Mode. Separate the back part of the transmitter (fig. 3), and mount all the parts in place (fig. 4). If relevant, connect the sensor to the input terminals. 7. FINAL MOUNTING 8. LED1 J1 HOLDOFF FAST NO J2 S1 ANT1 © ROKONET 1999 BATTERY HOLDON SLOW NC Note: the mark on the magnet's plastic case should be opposite the mark on the transmitter's case (fig. 5). S2 INPUT (+) J3 R11 J4 ANT2 5. IDENTIFICAZIONE DELL NOVA 71 AL RICEVITORE 5. ADRESSAGE DU NOVA 71 AU RECEPTEUR Français 4. RETIEZ LE COUVERCLE (Fig 1) 8. Note : La marque sur le contact magnétique devra être opposée à la marque du boîtier de l'émetteur (fig 5). Séparez la partie arrière de l'émetteur (fig 3) et montez tous les éléments (fig 4). Ensuite câblez le capteur aux entrées du bornier. 7. MONTAGE FINAL a. Choisissez le meilleur endroit pour une communication optimale, près du détecteur filaire (pour les capteurs). Installez le NOVA 71 le plus haut possible. b. Fixez temporairement l'émetteur à l'endroit choisi avec un adhésif double face. c. Provoquez un signal d'alarme (en ouvrant et refermant les entrées du bornier ) Et vérifiez que le récepteur ait bien reçu le signal. Si le signal d'alarme n'est pas détecté, changez de place le NOVA 71, et essayez à nouveau . Note : Pour de meilleurs résultats quand vous utilisez NOVA II, programmez le récepteur sur le Mode Communication et effectuez la vérification. Ensuite retournez en Mode Normal. NOVA 71 6. CHOIX†DU MEILLEUR ENDROIT POUR FIXER LE Note : Si pour quelque raison, il est nécessaire d'émettre à nouveau un message adressage, appuyez sur l'autoprotection du NOVA 71 pendant au moins 3 secondes. Le NOVA 71 doit se faire reconnaître du récepteur en inscrivant son code dans la mémoire d'adresses de celui-ci. Cette étape se réalise en suivant les instructions ci-après : a. Programmez le récepteur en Mode Adrossage (write) b. Au niveau du NOVA 71, retirez la pile du matériel d'isolation (fig 2). Appuyez sur l'autoprotection du NOVA 71 pendant au moins 3 secondes pour envoyer un message adressage. Vérifiez que le NOVA 71 ait bien été identifié par le récepteur. c. Programmez le récepteur en Mode Normal. Italiano 4. RIMUOVETE IL COPERCHIO FRONTALE (fig. 1). Il Nova 71 deve identificarsi al suo ricevitore scrivendo il suo messaggio di codice che deve essere registrato nella memoria del ricevitore. Ciò si ottiene : a. Disponete il ricevitore nel modo " Write" b. Rimuovete la batteria del materiale isolante (fig 2) Premete il tamper per circa 3 secondi per inviare un messaggio "Write". Verificate che il Nova 71 sia stato identificato dal ricevitore. c. Disponete il ricevitore nel modo "Normale" Nota: Se in caso fosse necessario rinviare un messaggio "Write", premete il tamper per circa 3 secondi. 6. SCEGLIETE LA POSIZIONE D'INSTALLAZIONE a. Scegliete una posizione ideale per la migliore comunicazione e vicino al rivelatore cablato (per sensori commutati). Installate il dispositivo il più in alto possibile. b. Fissate temporaneamente il dispositivo con dell'adesivo doppio. c. Provocate un segnale di allarme (aprendo o chiudendo i contatti terminali) e verificate che il ricevitore abbia ricevuto il segnale. Se il segnale non è stato ricevuto, riposizionate il Nova 71 e riprovate. Nota : Per un miglior risultato, quando usate un Nova II , posizionate il ricevitore nel modo "Controllo di Comunicazione "e dopo la ricezione e verifica,ritornate nel modo "Normale". Nota: Il marchio sulla plastica del contatto magnetico deve essere opposto al marchio del contenitore del trasmettitore (fig. 5). Separate la parte posteriore del trasmettitore (fig.3) ed installatelo (fig.4).Collegate il contatto ai terminali d'ingresso. 7. MONTAGGIO FINALE 8. ENTRADA N.C. (TB1) HOLDON SLOW/LENTO N.C. CLOSED - (IN) CERRADO(PUESTO) TB1 USADO TB1 SOLO ENTRADA N.A. (N.O.) (TB1) HOLDON SLOW/LENTO NA. (N.O.) CLOSED - (IN) CERRADO(DENTRO) TB1 USADO TB1 SOLO 4. Español ABRIR LA CUBIERTA (Figura 1). 5. ESTABLECIENDO LA COMUNICACION TRANSMISOR/RECEPTOR El NOVA 71 debe identificarse ante el receptor del sistema "escribiendo" su menasaje codificado en la memoria de dirección del receptor. Esto es llevado a cabo de la siguiente manera: a. Colocar el receptor en Modo WRITE. b. Remover la batería del material aislante. Un mensaje WRITE será enviado pulsando el botón tamper al menos 3 segundos. Verificar que el NOVA 71 ha sido identificado por el receptor. c. Colocar el receptor en Modo NORMAL. Nota: si por alguna razón es necesario re-transmitir un mensaje WRITE, pulsar el botón tamper al menos 3 segundos. 6. SELECCION DE†LA†UBICACION DE INSTALACION a. Seleccionar una ubicación adecuada para conseguir alta calidad de comunicacón y cerca del detector alambrado propuesto (para sensor exterior). Colocar la unidad a la máxima altura posible. b. Fijar temporariamente la unidad utilizando cinta adhesiva de doble cara. c. Generar una señal de Alarma (abriendo o cerrando momentáneamente los terminales de entrada) y verificar que el receptor ha recibido la señal. Si la señal de alarma no es detectada, reubicar el NOVA 71 e intentar nuevamente. Nota: Para obtener los mejores resultados al usar un NOVA II, colocar el receptor en Modo de Verificación de Comunicación, y luego retornarlo al Modo Normal. Separar la parte trasera del transmisor (Fig 3), y montar todas las partes en sus respectivos lugares (Fig 4). Si es necesario, conectar el sensor a los terminales de entrada. Atención: la marca en la caja pilástica del magneto debe colocarse frente a la marca en la caja del transmisor. 7. MONTAJE FINAL 8. HOLDON KLEMMANSCHLUSS NC ALLEINE HOLDON SLOW NO. CLOSED - (IN) TB1 USED KLEMMANSCHLUSS NO ALLEINE ZUSTAND DES ZUSTAND DES KLEMMKONTAKTS ALLEINE KLEMMKONTAKTS ALLEINE HOLDON SLOW N.C. CLOSED - (IN) TB1 USED SCHNELLINSTALLATION: E I N S T E L L U N G D E R S T E C K B R ü C K E N HOLDON STECKBR CKE /KONTAKT HOLDON NO. SLOW MAGNETKONTAKT MAGNETKONTAKT MAGNETKONTAKT ALLEINE MIT NO MIT NC KLEMMANSCHLUSS KLEMMANSCHLUSS J1 (1) N.C. SLOW OPEN - (OUT) NO. OPEN - (OUT) SIEHE (4) TB1 USED SLOW OPEN - (OUT) SIEHE (3) TB1 USED J3 J4 FREE J2 (2) TB1 ZUSTAND DES RELEVANT F R MAGNETSEN ALLEINE MELDUNG Deutsch 4. ABNEHMEN DES GEHÄUSEDECKELS (fig.1) 5. KOMMUNIKATIONSEINSTELLUNG Der NOVA 71 muß sich durch die Übertragung einer codierten Nachricht in den Adressenspeicher des Systemempfängers selbst identifizieren. Dies wird durch die†Ausführung folgender Schritte erreicht: a. Folgen Sie den Anweisungen zum Adressmodus in der Betriebsanweisung des†Empfängers. b. Verbinden Sie die Batterie mit der Batterieanschlußklemme (Fig 2). Während der Bestromungsphase wird eine Adressmeldung gesandt nachdem der Deckelkentakt des Melders min. 3 Sek. eingedrücht gehalten wird. c. Setzen Sie den Empfänger auf Normalmodus. Hinweis: Falls das Einlernen wiederholt werden muß, halten Sie für min. 3 Sek.†den Deckelkontakt des Melders gedrückt . 6. AUSWAHL DES MONTAGEORTES a. Wählen Sie eine Stelle die am besten für eine einwandfreie Übertragung geeignet ist†und nahe am anzuschließenden verdrahteten Detektor liegt. Montieren Sie das Gerät†an der höchstmöglichen Stelle. b. Montieren Sie das Gerät provisorisch mit Hilfe eines doppelseitigen Klebebandes†an dieser Stelle. c. Aktivieren Sie ein Alarmsignal (durch kurzzeitiges Öffnen und Schließen der†Eingangsklemme) und stellen Sie sicher, daß der Empfänger das Signal empfangen hat. Falls das Alarmsignal nicht detektiert wird, wechseln Sie den Montageort†des NOVA 71 und versuchen Sie es erneut. Hinweis: Für den besten Erfolg, bei Verwendung des NOVAEmpfänqers, setzen Sie den†Empfänger auf Communication Check - Modus und abhängig vom Empfang und von der Erkennung kehren Sie dann in den Normalmodus zurück. Hinweis: Die gekennzeichnete-Stelle des Magnetkontakts muß immer neben der gekennzeichnete-Stelle des Sende-Moduls positioniert werden (Fig.5). Falls erwünscht, verbinden Sie die Externe-Sensoren mit den Eingangsklemmen. Trennen Sie das Gehüuse-Rückteil (Fig.3) und montieren Sie das Rückteil an seiner†endgültige Position (Fig.4). 7. ENDGÜLTIGE MONTAGE 8. FCC ID: JE4WT7IV2 CONSULT WITH YOUR LOCAL RADIO AGENCY ABOUT THE POSSIBILITY OF OPERATION OF THIS DEVIC. © RO 98 T 19 NE KO fig. 2 fig. 3 fig. 5 fig. 1 fig. 4 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance, Rokonet Electronics Ltd. could void the user’s authority to operate the equipment. ROKONET LIMITED WARRANTY Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 18 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week. MAGNETICO+ ENTRADA N.A. (N.O.) (TB1) HOLDON SLOW/LENTO NA. (N.O.) OPEN - (OUT) ABIERTO(FUERA) TB1 USADO AMBOS (4) geschlossen ist, sendet das Ger t eine Klarmeldung an den Empf nger. 4. Nur wenn der Magnetkontakt geschlossen und der Klemmkontakt offen ist, sendet das Ger t eine Klarmeldung an den Empf nger. T 1998 MAGNETICO SOLO HOLDON SLOW/LENTO NA. (N.O.) OPEN - (OUT) ABIERTO(QUITADO) LIBRE MAGNETICO SOLO 1. HOLDON bedeutet eine Todzeit von 2,5min; HOLDOFF bedeutet keine Todzeit. 2. Im Falle eines Ersch tterungsmelders, w hlen Sie die Einstellung FAST. 3. Nur wenn der Magnetkontakt und der Klemmkontakt © ROKONE APLICATION /TEMA J1 (1) J2 (2) J3 J4 TB1 LOGICA (MAGNETICO & TB1) 1. HOLDON - Significa 2.5 minutos de tiempo muerto, en HOLDOFF la reaccion es immediata, no hay tiempo muerto. 2. Si usa reaccion rapida para sensores de vibraciones, elija (FAST JP2). 3. Solo si el magnetico esta cerrado y las entradas externas (TB1) MAGNETICO+ ENTRADA N.C. (TB1) HOLDON SLOW/LENTO N.C. OPEN - (OUT) ABIERTO(FUERA) TB1 USADO AMBOS (3) PARA UNA INSTALACION: R A P I D A A J U S T E D E L O S P U E N T E S B1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2002:03:24 16:40:19 Producer : Acrobat Distiller 4.0 for Macintosh Author : Yael Creator : FreeHand 9: LaserWriter 8 Z1-8.3.2 Title : NOVA T71 Modify Date : 2002:04:09 17:39:59+03:00 Page Count : 2EXIF Metadata provided by EXIF.tools