Rosslare DRU955BT Desktop Reader & Programmer for UHF/MIFARE/BLE User Manual A4 1 page

Rosslare Enterprises Ltd Desktop Reader & Programmer for UHF/MIFARE/BLE A4 1 page

User Manual

DR-U955BT   Multi-format Desktop Reader User Manual 1 1. Introduction The DR-U955BT is an advanced desktop reader for MIFARE Classic® EV1, MIFARE® DESFire® EV1, UHF, and BLE. It reads the ID data of the credential, and transmits the relevant ID data to any connected access control software, such as Rosslare’s AxTraxNG™. It has a slim and attractive design and is built for convenience and portability. With its USB computer interface, it is quick and easy to install and runs without any additional power source. Using the BLE-Admin or BLE-ID apps, the reader can function like other Rosslare BLE readers and can transmit the BLE ID to the reader. The Hardware Configuration Tool (HCT) can be used to configure the reader’s specifications, such as the Wiegand format used. The reader reads the CSN ID of each credential (MIFARE, UHF, BLE) and transmits it to the software with the bit length pre-configured by the user. Figure 1: DR-U955BT  2. Technical Specifications 2.1 Electrical Characteristics Operating Voltage Range 5 VDC (USB powered) Standby Current 250 mA Max. Operation Current 300 mA Supported Transponders MIFARE, UHF, BLE Read Card Distance UHF and MIFARE: Up to 5 cm (2 in.) BLE: Up to 6 m (19.7 ft) Operation Frequency • RFID: 13.56 MHz  • DR-U955BT US: 902–928 MHz (America) RFID • DR-U955BT EU: 865–868 MHz (Europe) RFID • Bluetooth: 2.402-2.480 GHz Output Formats  Supports Wiegand 26-Bit to 64-Bit 2.2 Environmental Characteristics Operating Environment Indoor use Operating Temperature Range  Storage Temperature Range -20°C to 63°C (-4°F to 145°F) Relative Humidity Range 0 to 95% (non-condensing) 2.3 Physical Characteristics Weight 130 g (4.6 oz) Dimensions (L x W x H) 123 x 70 x 16.2 mm (4.9 x 2.8 x 0.6 in.) 3. OperationThe DR-U955BT appears as a COM port device when plugged in to a PC and can be used for any application. When a card is presented to the reader, the reader outputs the Wiegand ID data on the COM port only once until a new card is presented. You must use the AxTraxNG software to enroll cards. Please refer to the relevant appendix in the AxTraxNG™ Software Installation and User Manual. For the enrollment reader to function in AxTraxNG, you must know the COM port being used. The COM port can be found in Microsoft Device Management’s driver details under ‘Ports (COM & LPT)’. The port being used appears as “USB serial Port (COMx)”, where x is the number of the port used.  SMART-20°C to 63°C (-4°F to 145°F)
 2  0706-0960664+00 Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  This device may not cause harmful interference.  This device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them. Contact InformationUnited States and Canada Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com  Europe Rosslare Israel Ltd. 22 Ha'Melacha St., P.O.B. 11407 Rosh HaAyin, Israel Tel:  +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com  Latin America Rosslare Latin America Buenos Aires, Argentina support.la@rosslaresecurity.com  China Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com  Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com  India Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com   CERTISO  9001ISO  14001FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forthfor an uncontrolled environment . This transmitter must not be co-located or operating in conjunction withany other antenna or transmitter. This equipment should be installed and operated with minimum distance20cm between the radiator &you body.

Navigation menu