Rosslare PYR-2011G Advanced Wireless PIR PYR-2011G User Manual Installation Manual

Rosslare Enterprises Ltd Advanced Wireless PIR PYR-2011G Installation Manual

Users Manual

Download: Rosslare PYR-2011G Advanced Wireless PIR PYR-2011G User Manual Installation Manual
Mirror Download [FCC.gov]Rosslare PYR-2011G Advanced Wireless PIR PYR-2011G User Manual Installation Manual
Document ID1134020
Application IDA3+1lOne4zI4rjgp6r65ag==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.26kB (465709 bits)
Date Submitted2009-07-06 00:00:00
Date Available2009-07-06 00:00:00
Creation Date2009-07-02 14:18:11
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2009-07-02 14:29:08
Document TitleInstallation Manual
Document CreatorAcrobat PDFMaker 8.1 for Word
Document Author: Doron Bodner

PYR-2011G
Installation Instructions
Advanced Wireless PIR
1.
2. Introduction
The PYR-2011G Digital Wireless Passive Infrared (PIR) motion
detector is a high-performance, ultra low power intrusion sensor
with advanced design ideal for residential and commercial
applications.
The PYR-2011G's SSFL technology (look down) allows detection at
proximity of 50cm from its mounting location.
This unit works with Rosslare’s control panels like HomeLogiX™,
which is wireless, and AuraSys™, which is wired.
For the PYR-2011G to work with AuraSys™, the AuraSys™ panel
must have the XR-16 wireless expansion.
The PIR senses slight motion within a coverage area by detecting
infrared energy with a Pyroelectric sensor.
Serving as an anti-intrusion sensor, the PIR can monitor open space
within line of sight.
“Walk & Radio” test is easy, as well as friendly and makes it very
comfortable for placing and setting. The PYR-2011G uses fuzzy logic
to improve detections and reduce false alarms. It also provides
digital temperature compensation and self-test capability.
The PYR-2011G is supplied with front and back tampers for high
security.
As a wireless device, it includes a supervised mechanism as well as
a battery-checker and tamper announcement.
Note 1:
This product must be installed professionally, and has only one
available channel.
Note 2:
Pursuant to FCC §15.21 [ 54 FR 17714 , Apr. 25, 1989, as amended
at 68 FR 68545 , Dec. 9, 2003], changes or modifications made to equipment,
which are not expressly approved by Rosslare Enterprises, Ltd., may void the
user's authority to operate the equipment.
3. Technical Specifications
3.1 Optical Characteristics
Lens Type: Spherical
Field of view: 115°
Max. Coverage: 14 x 14 m (46 x 46ft)
No vertical adjustment
3.2 Electrical Characteristics
Battery type: CR123 (3V/1300mhA)
Current Consumptions: Standby 15µa, 10ma transmission.
Battery Life (nominal): 3 years (150tr/day)
Detector Type: Dual PYRO IR element (IR filter 5um÷14um)
Alarm Signaling: Red LED 2 seconds on (push button setting)
Events Transmission: Alarm, Tamper, Low battery.
Sensitivity: 3 levels fuzzy logic (jumper setting)
Speed Detect: 0.2m/s ÷ 3m/s ∆ t= 1.1°C
Operating Humidity: 0 to 95% (non-condensing)
RFI Protection: >20 V/m up to 1000 MHz
3.4 Physical Characteristics
Dimensions: 127mm(5 in)H x 80mm(3.15 in)Wx63mm(2.48 in)
D (Fits US Gang Box)
Weight: 0.27 lbs (123g) (without battery)
Compliance with standard: CE
(0.66 ft/s ÷ 9.84 ft /s ∆ t= 34° F)
Temperature Compensation: Digital dual slope (+/- 1°C)
Tamper Switches: Back and front Cover tampers
Supervisory Signals: Electronic malfunction, temperature out of
range (by flashing LED)
Arming types:
Normal- 2 minutes sleep, followed by last alarm
Dynamic- 2 minutes sleep, followed by last movement (retriggerable)
Test modes- walk test (no sleep) 1 min
Radio test- 10 transmissions
RF Transmission Characteristics
Frequency: model H = 868.35 MHz; model G = 433.92 MHz
Range: 200 meters (590.55ft) open field conditions
Supervision transmission: automatic, at 20-minute intervals
Self check: 3 hours from last alarm (retriggered)
3.3 Environmental Characteristics
Operating Environment: Indoor use
Operating Temperature: -10 to 60°C (14 to 140°F)
0706-0960110+02
4. PYR-2011G Features
• Advanced micro-controller electronics: 10-bit A-to-D and
advanced algorithms for superior movement speed spectrum
analysis
• Shielded dual-element Pyro: Inside a dust-proof chamber
designed to reduce thermal changes and insect protection
• Three levels of sensitivity: High, medium or low; by jumper
selection
• Power saving: Two transmission modes by jumper
• Back and Front Cover tamper switches: Protection against
cover or wall removal for higher security.
• Easy & comfortable installation: Easy installation without PCB
adjustment.
• Easy Walk & Radio test: By single contactless switch.
• Energy detection system: By using fuzzy logic algorithms,
detection is improved and false alarms are reduced
• Environment temperature compensation: Maintains constant
detection capability
• Adaptive filter: Compensates for changes in a detected object’s
speed
• Continuous monitoring: Sends visual alerts in case of malfunction
(digital & analog) and temperature out of range
5. Installation
5.1 General
The PYR-2011G is designed for easy installation. Only a few steps
are required to install the PIR device.
To enable the Curtain Adapter for PIR detection on a focused
area, such as a corridor, or across a window or opening, follow
the instruction outlined in section 5.
When you are sure of the mounting location, follow the steps for
mounting the PIR, on a flat surface or in a corner, described
below.
5.2 Opening the PYR-2011G
The PYR-2011G housing can be opened by unscrewing a Philipshead screw (1) and pushing the safety latch (2) to “unlock”.
mounting of the unit. Ensure the PIR has a “view” of the area
under surveillance and is free from obstructions.
The PYR-2011G has a detection range of 14.7m (48 ft.) when
placed at a height of between 1.8m and 2.3m.
When using the Corner Mount, first of all place the plastic
bracket in the Corner, at the exact chosen location. Pay
attention, the Bracket has a Direction, the narrow edge faces
downwards. Next, attach it firmly to the wall; all 4 screws must be
inserted. Now inset the Body of the PYR into place over the
plastic bracket, using the corner mounting holes. If the installation
is done properly the plastic pipe/pole will press the “back
tamper” correctly.
5.3 Mounting the PYR-2011G PIR
Select an area for mounting the PYR-2011G, and ensure the
location is flat, either a wall or a 90-degree corner, for perfect
0706-0960110+01
5.4 Wall Mounting
5.5 Closing the detector
The PIR housing has “dimple” points for insertion of screws, for
either wall-mounting or corner mounting (refer to detailed
pictures below). Remove the PC board prior to mounting.
After mounting the detector, insert a battery (refer to 6). Place
the PCB back in place and close the detector in reverse order.
Wait till detector finishes self-test (refer to Signaling Table), and
perform a self test.
NOTE: Be careful not to touch the pyro-electric unit on the board. Touching
the unit will gravely affect its ability of the unit to work properly.
Note: When using the swivel mount refer to the BR-11 installation manual.
6. Adding the Curtain Adapter
Use the Curtain Adapter for detecting movement in narrow places
(corridors) or across surfaces (window).
Remove the lens only to add or remove the Curtain Adapter.
1) Turn the top part of the PYR-2011G over and locate the lens'
“holder pin” (A).
2) Gently remove the pin using a screwdriver under the “holder
pin” by lifting the pin up out of its place.
3) Gently push the two latches on the side of the lens inwards,
turn the housing over and pop off the lens.
4)
5)
Replace the Lens. Turn the assembly over and replace the
“holding pin” that holds the Spherical lens in place. Be sure to
place the “holding pin” between the lens tab and the
housing, with the flat side toward the lens tab.
Lens
Curtain
Adaptor
Place the Curtain Adapter onto the lens area on the front of
the housing. Be sure to place the guide pins into the two holes
at the lower part of the lens area.
7. Changing the battery
When the battery is weak, the PYR-2011G will send a signal to the
panel, including LED signals (refer to Signaling Table) indicating a
weak battery. Although the detector can continue working for an
additional amount of time, it is prudent that the battery be
replaced as soon as possible.
To change the internal battery:
1) Follow the directions in section Opening the PYR-2011G.
2) Remove the PCB unit from the housing by pressing down on
the retaining latches and tilting the PCB out from the bottom.
3) Remove the battery and replace with a 3vdc, 1300 mAh
model CR123A only. Pay attention to the polarity of the
battery when inserting into the holder.
CAUTION: Danger of explosion if battery is replaced incorrectly. Replace only
with 3V Lithium GPCR123A or equivalent. Dispose of used batteries according
to the manufacturer’s instructions.
4)
Battery
Place
PYR-2011 PCB back view
Replace the PCB cover of the PYR-2011G and the locking
screw.
8. Jumper and Tamper Setting
PYR-2011G has two jumpers, JP1 and JP2 and reed switch S3 (test
mode) operated by placing a magnet over it.
8.1 Sensitive Level Jumper (JP2)
To prevent false alarms in harsh environments, three sensitivity
modes were designated:
• Low – for harsh environments, jumper on pins 2 and 3
• Medium – for normal usage, jumper off
• High – for high sensitivity when there is little chance of false
alarms, jumper on pins 1 and 2
8.2 APS – Auto Power Save Mode (JP1)
To save power, the PYR-2011G goes into sleep mode after sending
an alarm. The time the device will be latent is set by the radio
mode jumper, JP1.
• Normal (always 2 minutes between alarms) – no jumper.
• Dynamic (2 minutes retriggered between alarms) – jumper
on.
When the dynamic mode is set, an alarm event will be sent only if
there were 2 minutes of silence prior to the current alarm. This
setting is useful for places with a high level of traffic, such as
factories, shops, etc.
8.3 Back Tamper (R11)
The PYR-2011G has both front and back tamper detection. Front
tamper detection is on by default and it is activated when the
cover is opened cannot be changed. The back tamper detection
is activated when the detector is pulled off the ceiling and is
disabled by default, to enable the back tamper detection cut the
back tamper wire - R11 - which is marked on the PCB as a scissor
print.
8.4 Test Mode Switch (S3)
The detector utilizes a contactless switch (enabling easy testing
without opening the case):
Walk Test – Place a magnet over the right side of the lens for 1
second only; PIR functionality will be evaluated, for a 1 minute
0706-0960110+01
period. (After self check at power up the walk test is automatic
enable for 2 minutes.)
Radio Test – Place a magnet over the right side of the lens for more
than 3 seconds; the red indicator illuminates. 10 Alarms events are
transmitted with 4 second intervals for a total transmission time of
approximately 40 seconds.
This test is to insure clear RF passes between the detector and the
control panel.
In all modes the LED will remain activate at all trouble
announcements.
Refer also to panel manual for RF testing details.
9. Testing the Detector
The PYR-2011G PIR has a built-in walk test function where the LED of
the PIR is enabled. This test is used to check the detection of the
PIR and the coverage pattern.
To perform a walk test:
1) Ensure all of the settings in the PIR are adjusted as necessary
for the location according to the installation instructions
above.
2) Insert battery in the closed case as described above. The LED
flashes on for 2 seconds and off for 2 seconds for a period of 1
minute. Then the LED turns off. At this point a walk test can be
performed. As default, perform a walk test of 2 minute at the
end of the self test. If more than 2 minute goes past, refer to
paragraph 3.
3)
4)
5)
6)
Place a magnet over the right side of the lens for 1 second
only.
With the LED enabled the LED flashes every time the detector
detects motion. There is a two second wait period before the
next detection.
It is recommended that the installer test the detection by
going over the protected area and seeing that the detection
pattern is good.
After 1 minute, the LED goes off. If a new walk test is needed,
go again to paragraph 3.
10. Signaling Table
The LED on the front of the PYR-2011G is used to send several signals to the user. The following table describes the signals for different
activities:
Activity
LED Signal
Warm-Up
The LED flashes on for 2 seconds and off for 2 seconds for a period of 1 minute. If the warm-up is successful,
the LED stops flashing and the system is ready for detection.
Detect Condition
The LED flashes on for 2 seconds and then turns off.
PIR Problem
The LED flashes on for 1 second and then off for 1 second. A PIR check is conducted every 3 hours.
Temperature Problem
The LED flashes on in short bursts.
Weak Battery
LED OFF and ON alternately during Alarm, Tamper event
11. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) ONE YEAR LIMITED WARRANTY is
applicable worldwide. This warranty supersedes any other warranty. Rosslare's ONE YEAR
LIMITED WARRANTY is subject to the following conditions:
applied for labor or parts with respect to defects covered by this warranty, provided that the
work is done by Rosslare or a Rosslare authorized service center.
Warranty
Warranty of Rosslare's products extends to the original purchaser (Customer) of the
Rosslare product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that
the PYR-2011G Advanced wireless PIR, to be free from defects in materials and assembly
in the course of normal use and service. The warranty period commences with the date of
shipment to the original purchaser and extends for a period of 1 year (12 Months).
Warranty Remedy Coverage
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the
Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by
the Customer during the warranty period in accordance with the terms of this warranty.
Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR
SUBSIDIARIES representative, return of the failed product(s) is not immediately required.
If ROSSLARE has not contacted the Customer within a sixty (60) day holding period
following the delivery of the warranty claim, Customer will not be required to return the failed
product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES
LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE
ENTERPRISES LTD. AND /OR SUBSIDIARIES.
To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA
number after which, the product must be returned to the Manufacturer freight prepaid and
insured
In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day
holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be
applied to each Product for labor required in the evaluation.
Rosslare will repair or replace, at its discretion, any product that under normal conditions of
use and service proves to be defective in material or workmanship. No charge will be
0706-0960110+01
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the
operation or performance of any Product or any systems in which a Product is incorporated.
This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE,
which is attached to or used in conjunction with a Product, nor to any Product that is used
with any ancillary equipment, which is not furnished by ROSSLARE.
This warranty does not cover expenses incurred in the transportation, freight cost to the
repair center, removal or reinstallation of the product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from Customer's improper
testing, operation, installation, or damage resulting from use of the Product in other than its
normal and customary manner, or any maintenance, modification, alteration, or adjustment
or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects
or damage due to lightning or other electrical discharge. This warranty does not cover repair
or replacement where normal use has exhausted the life of a part or instrument, or any
modification or abuse of, or tampering with, the Product if Product disassembled or repaired
in such a manner as to adversely affect performance or prevent adequate inspection and
testing to verify any warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of the Product.
Service life of the product is dependent upon the care it receives and the conditions under
which it has to operate.
In no event shall Rosslare be liable for incidental or consequential damages.
THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER
OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL
OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE SPECIFICALLY EXCLUDED.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS
OF USE, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF
PROFITS, ARISING OUT OF THE INSTALLATION, USE, OR INABILITY TO USE SUCH
PRODUCT, TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE
DISCLAIMED BY LAW.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION
OF THE PROVISIONS OF THIS LIMITED WARRANTY.
Limited Warranty Terms
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES
LTD. AND IT’S SUBSIDIARY’S WARRANTY.
12. C ontact information
10B
Asia Pacific, Middle East, Africa
24B
Headquarters:
28B
905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong
Tel:+852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com
United States and Canada
25B
1600 Hart Court, Suite 103 Southlake, TX, USA 76092
Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com
Europe
26B
Global Technical Support & Training Center:
29B
HaMelecha 22 Rosh HaAyin, Israel 48091
Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com
South America
27B
Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228
Web Site: www.rosslaresecurity.com
30B
0706-0960110+01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
Signing Date                    : 2009:07:02 14:29:08+03:00
Signing Authority               : ARE Acrobat Product v8.0 P23 0002337
Annotation Usage Rights         : Create, Delete, Modify, Copy, Import, Export
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Company                         : Rosslare Security
Source Modified                 : D:20090702111410
Creator Tool                    : Acrobat PDFMaker 8.1 for Word
Modify Date                     : 2009:07:02 14:29:08+03:00
Create Date                     : 2009:07:02 14:18:11+03:00
Metadata Date                   : 2009:07:02 14:29:08+03:00
Document ID                     : uuid:ebfef9bc-2d90-4527-bb76-0c8858224bdd
Instance ID                     : uuid:ae288761-8b08-49cd-bddf-7915d5da99a7
Subject                         : 3
Format                          : application/pdf
Creator                         : Doron Bodner
Title                           : Installation Manual
Has XFA                         : No
Page Count                      : 5
Page Layout                     : OneColumn
Author                          : Doron Bodner
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GCD-PYR-2011G

Navigation menu