Ruckus Wireless T310 T310 (C/D) Access Point User Manual T310c Access Point Quick Setup Guide
Ruckus Wireless, Inc. T310 (C/D) Access Point T310c Access Point Quick Setup Guide
Contents
- 1. Manual Regulatory Statement
- 2. T310c User Manual
- 3. T310d User Manual
T310c User Manual
T310c Access Point Quick Setup Guide • このガイドの日本語版は https:// support.ruckuswireless.com でご覧ください。 • Declaration of Conformity • 이 가이드의 한국어 버전은 웹 사이트 (https:// support.ruckuswireless.com) 에서 확인하시기 바랍니다. • Ruckus Wireless AP Getting Started Guide • Veja a versão em português (Brasil) deste guia em https:// support.ruckuswireless.com. • Puede ver la versión en español (América Latina) de esta guía en https://support.ruckuswireless.com. • Regulatory Statement • This Quick Setup Guide FIGURE 1 T310c Package Contents Before You Begin NOTE: The minimum software revision for the T310c is ZoneDirector (ZD) 10.1 or later, or SmartZone (SZ) 3.6 or later, or standalone AP firmware 108.0 or later. This Quick Setup Guide provides step-by-step instructions on how to field-install the Ruckus Wireless T310c access point (AP). For detailed information on planning the installation, performing a site survey, and operating the T310c, refer to the Ruckus Wireless Outdoor Access Point User Guide, available at https://support.ruckuswireless.com. WARNING! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. WARNING! Installation of this equipment must comply with local and national electrical codes. CAUTION! Make sure that you form a 80mm - 130mm (3”-5”) drip loop in any cable that is attached to the AP or the building. This will prevent water from running along the cable and entering the AP or the building where the cable terminates. CAUTION! Be sure that grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors. CAUTION! Make sure that proper lightning surge protection precautions are taken according to local electrical code. WARNING! Ruckus Wireless strongly recommends that you wear eye protection before mounting the T310c. Before deploying Ruckus Wireless products, please check for the latest software and the release documentation. • Release Notes and other user documentation are available at http://support.ruckuswireless.com/documents. • Software upgrades are available at http:// support.ruckuswireless.com/software. • Open source information is available at http:// opensource.ruckuswireless.com. • Software license and limited warranty information are available at http://support.ruckuswireless.com/warranty. Before deploying your Ruckus Wireless Access Point, verify that all items listed in Package Contents are included in the package. If any item is damaged or missing, notify your authorized Ruckus Wireless sales representative. Also, make sure that you have the required hardware and tools. Connecting And Sealing the RJ-45 Cables Connect and seal the RJ-45 cable(s) using the M25 data cable glands shown in the Figure below. WARNING! Do not use any PoE injector not tested and approved by Ruckus Wireless to power the T310c Access Point. FIGURE 2 T310c LEDs and Ports Required Hardware and Tools • No. 2 Phillips screwdriver • Small flat-blade screwdriver • Torque wrench or torque screwdriver with sockets • Long-nose pliers • Electrical wire stripping and terminal crimping pliers • Pipe or pole --OR-- a sturdy flat surface • Electric drill with drill bits and customer-supplied wall anchors, flat washers, and hex nuts for flat-surface mount Package Contents A complete T310c field installation package includes all of the items listed below (see Figure below for illustrations): • T310c Access Point (A) This Guide in Other Languages • M25 data cable gland (B) • 请从以下网站请得请指南的请体中文版 https:// support.ruckuswireless.com. • Ground wire with lug (C) • Vous trouverez la version française de ce guide à l'adresse suivante https://support.ruckuswireless.com. • Four steel pipe clamps Copyright ® 2017 Ruckus Wireless, Inc. Published September 2017, Part Number 800-71622-001 Rev A Mounting Instructions 1. Feed the end of the cable through the sealing nut, rubber O-ring, clamping ring assembly and cable gland base as shown. NOTE: Do not seat the clamping ring and rubber O-ring into the gland body until the gland body has been torqued to spec. • Pole/Wall Mount Bracket Kit (D) • Service Level Agreement/Limited Warranty Statement Page 1 of 3 FIGURE 3 RJ-45 cable and cable gland assembly on the mounting bracket as a template to mark the locations of the mounting holes. FIGURE 6 Mounting bracket on a pole NOTE: The mounting bracket can be mounted to a vertical or horizontal surface to support the AP in the required orientation. FIGURE 5 Mounting bracket on a flat surface 5. Continue with Mounting the AP. Mounting the AP 2. Use a wide flat-blade screwdriver to remove the required (PoE IN) blanking cap from the AP. 3. Remove the mounting bracket from the mounting surface. 3. Connect the cable to the Ethernet port on the AP. 4. Drill holes required for the customer-supplied mounting hardware. 4. Tighten the cable gland base into the AP chassis to 7 N.m or 62 in-lbs. 5. Attach the mounting bracket to the flat surface using the mounting hardware. 5. Wrap the clamping ring assembly around the rubber Oring. Make sure that the clamping ring assembly fully encloses the rubber O-ring. 6. Using the mounting hardware instructions, tighten the hardware to secure the mounting bracket. 6. Seat the clamping ring assembly and rubber O-ring in the cable gland base. 7. Hand-tighten the sealing nut. Attaching the Mounting Bracket To A Flat Surface 1. The AP mounting bracket attaches to the AP using a captive screw. Use a medium flat-blade or No. 2 Phillips screwdriver to loosen the captive screw (A in the Figure below) and pull up on the end of the bracket to remove the bracket from the AP (B in the Figure below). FIGURE 4 Removing the mounting bracket 1. Snap the AP back onto the mounting bracket (A in the Figure below), and use a medium flat-blade or No. 2 Phillips screwdriver to tighten the captive screw to 1.1 N.m or 10 in-lbs to secure the bracket to the AP (B). FIGURE 7 Attaching the mounting bracket to the AP 7. Continue with Mounting the AP. Attaching the Mounting Bracket to a Pole 1. The AP mounting bracket attaches to the AP using a captive screw. Loosen the screw (A in Figure 4) and pull up on the end of the bracket to remove the bracket from the AP (B in the Figure above). 2. Insert the open end of one steel clamp (D in the Figure above) into two of the slots on the mounting bracket. NOTE: The mounting bracket can be mounted to a vertical or horizontal pole to support the AP in the required orientation. 2. Optional Step: If you also need to lock the mounting bracket to the AP, then use a matching security screwdriver to screw the customer-supplied locking stainless steel 6mm M3 panhead security screw through the mounting bracket and into the AP chassis. CAUTION! Make sure that the customer-supplied locking stainless steel M3 panhead security screw is no longer than 6mm. If the security screw is longer than 6mm, it can damage the AP chassis. 3. Using either of the two options shown, use the clamp(s) to attach the mounting bracket to the pole. Tighten the clamps to 3 N.m or 27 in-lbs, or per manufacturer’s specifications if the factory-supplied clamps are not used. 4. If necessary, daisy-chain the other steel clamps to accommodate larger poles. 2. Using either of the two options shown in Figure 5, hold the mounting bracket at the location on the mounting surface where you want to mount the AP. Use the holes Copyright ® 2017 Ruckus Wireless, Inc. Published September 2017, Part Number 800-71622-001 Rev A Page 2 of 3 FIGURE 8 Locking the mounting bracket to the AP You have completed mounting the AP to the mounting bracket. Earth Grounding the AP CAUTION! Make sure that earth grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors. NOTE: The color coding of ground wires varies by region. Before completing this step, check your local wiring standards for guidance. Using the factory-supplied ground wire and ground screw/ washer set, connect a good earth ground to the AP chassis ground point. CAUTION! The T310c AP includes one 9mm stainless steel M6x1 earth ground screw with split lock and flat washers. Make sure that any replacement screw is no longer than 9mm. If a screw is longer than 9mm, it can damage the AP chassis. Copyright ® 2017 Ruckus Wireless, Inc. Published September 2017, Part Number 800-71622-001 Rev A FIGURE 9 Connect good earth ground to AP here Congratulations! You have mounted your T310c access point. Troubleshooting CAUTION! If required, you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port. DO NOT DO THIS UNLESS SO INSTRUCTED. (Doing this resets the AP IP address to 192.168.0.1.) NOTE: After a reset, you can access the internal AP web interface using https://192.168.0.1. Your device must use any other address from 192.168.0.2 through 192.168.0.254, with subnet mask 255.255.255.0. The username is super, and the password is sp-admin. Refer to the Outdoor Access Point User Guide for information on configuring and operating the AP. This document is available at https://support.ruckuswireless.com. For More Information For information on how to configure and manage the AP, refer to the Ruckus Wireless Outdoor Access Point User Guide, available from https://support.ruckuswireless.com. Page 3 of 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : Brocade Create Date : 2017:09:18 20:44:29+00:00 Modify Date : 2017:09:18 20:44:29+00:00 Creator : AH XSL Formatter V6.4 R1 for Windows (x64) : 6.4.2.26942 (2016/12/07 15:30JST) Producer : Antenna House PDF Output Library 6.4.928 (Windows (x64)) Title : T310c Access Point Quick Setup Guide Trapped : False Page Count : 3 Page Mode : UseOutlines Language : EN-USEXIF Metadata provided by EXIF.tools