SAN FORD MACHINERY JY16008RSF RADIO FREQUENCY REMOTE CONTROL SWITCH User Manual Remote control panel function
SAN FORD MACHINERY CO., LTD RADIO FREQUENCY REMOTE CONTROL SWITCH Remote control panel function
Users Manual
Dust Cyclone- Remote control panel function Control panel wire diagram (Refer to attachment 1) Switch 1. Switch on the power source, the panel will beep for 0.25seconds. 2. Press the SW1 button until you hear a beep that lasts for 0.15 seconds, this beep will go off twice. Thereafter, press the D button on the hand held remote controller to send a code to the panel, which will read the code in 5 seconds completing the CODE SAVE CPU EEPROM, 0.15 second beep, stopping for 0.15 seconds continuously for three times will mean that you have completed the setup. If this is not done within the 5 second time frame, you will have to repeat the code link set up again. Repeating this will not clear the first code setup. 3. Press the A button on the hand held remote controller, the control panel will activate the RELAY (RL1) ON + LED OUT ON and beep for 0.15 seconds. 4. Press the B button on the hand held remote controller, the control panel will activate the RELAY (RL1) OFF + LED OUT OFF and beep for 0.15 seconds. 5. In RELAY OFF mode, press the green button on the switch (CN3) to activate RELAY (RL1) ON + LED OUT ON and will beep for 0.15 seconds. 6. In RELAY ON mode, press the red button on the switch (CN3) to activate RELAY (RL1) OFF + LED OUT OFF and will beep for 0.15 seconds. Page 1 JY16008RSF Remote control panel function Pressure switch input: 1. When the PS_SW is 0, the forced output is RELAY (RL1) OFF. This will affect the other functions. 2. When the PS_SW is 1, RELAY (RL1) will function normally. 3. Refer to the diagram on the right: Hand held remote controller function: 1. A is ON, B is OFF、C(NC)、D is code output Pressure switch input 2. First pressing D will send a code signal, and the LED will flash, simultaneously press the set button on the control panel to save the code. 3. Pressing A , the LED will flash and signal ON 4. Pressing B, the LED will flash and signal OFF 5. Output frequency is 433MHZ Control panel receiver : DATASHEET per attachment (2) LED Page 2 JY16008RSF Remote control panel function ATTACHMENT(1) Page 3 1 12V C4 470PF 12V 12V ANT 433.92MHZ PCB LOOP LED Q1 2SC3356 R4 47R C2 3PF R5 150K C6 R1 10K R3 R6 47R 47K R2 330K U1 EV1527 Q1 2N3906 12V C1 104Z SR1 C3 13PF K3 OSC K3 VCC K2 GND K1 OUT K0 K2 433.92 K1 K0 Title Size TX-4KEY-434 Number Revision A4 Date: File: 鎮鎮 遙遙遙遙遙\TX-4KEY-1527.sch Drawn By: 21-Jan-2016 D:\PCB\ Sheet of JY16008RSF Remote control panel function ATTACHMENT(2) Page 4 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2006/8/16 v1.0 Industry Canada statement: This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1) l’appareil ne doit pas produire de brouillage; 2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract Author : Owner Create Date : 2016:03:03 16:04:34+08:00 Modify Date : 2016:06:16 17:18:33+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Owner Title : Microsoft Word - Remote control panel function.doc Metadata Date : 2016:06:16 17:18:33+08:00 Producer : Bullzip PDF Printer / www.bullzip.com / Freeware Edition Document ID : uuid:9ed69751-e7a0-4744-8b3f-f45c645eae58 Instance ID : uuid:c4600a72-97a2-4645-a391-bdbacb8d4cba Page Count : 7EXIF Metadata provided by EXIF.tools