SD Biosensor 01GM24 NFC Blood Glucose Monitor User Manual Link manual part1

SD Biosensor, Inc. NFC Blood Glucose Monitor Link manual part1

Link manual part1

Link™0.3 NFCLink™0.3 NFCMentor NFCMentortortortortortortortortortortortortortortortortortortortortortortortortortortor NF NFCLink0.3NFCFCC ID : RPJ01GM1401680123
ISD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM Dear SD GlucoNavii® Link0.3 NFC  System Owner;Thank you for choosing SD GlucoNavii® Link0.3 NFC  Blood Glucose Monitoring System. Your new SD GlucoNavii® Link0.3 NFC  Blood Glucose Monitoring System is an important tool that can help you better manage your diabetes. Important steps for using the System are inside this guide. Please read it carefully. If you have questions, we are here to help.Please contact SD Biosensor, Inc.Tel : +82-31-300-0400Fax : +82-31-300-0499website : www.sdbiosensor.comWe oer assistance 24 hours a day, 365 days a year in many languages. You can also visit www.sdbiosensor.com for diabetes management tools and product demonstrations.Please refer to the instructions with following symbols in this User Instruction Guide.To identify conditions or practices that could result in damage to equipment or other property.To provide an additional useful information. Before using any product to test your blood glucose, read all instructions and practice the test. Do all quality control checks as directed and consult with a diabetes health care professional. These recommendations apply to all blood glucose monitoring systems and are supported by the American Association of Diabetes Educators, the American Diabetes Association, the U.S. Food and Drug Administration, and the Advanced Medical Technology Association.CAUTIONNOTENOTEnuGsWUZGumj|GluYWXZW[X^YUGGGX YWXZTW[TX^GGG㝘䟸G\aXYa[X
2SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM TABLE OF CONTENTSChapter 1 : Understanding Your New System    1.  Before You Start Testing                      2.  Special Information for Healthcare Providers and Caregivers                                  3.  Indication for Use 4.  Product Description and the Principle of the use5.  The Complete SD GlucoNavii® Link0.3 NFC Blood Glucose Monitoring System6.  SD GlucoNavii® Link0.3 NFC  Meter7.  SD GlucoNavii® Link0.3 NFC8.  SD GlucoNavii® Link0.3 NFC  Accessories 9.  Changing the Battery10.  Meter Set up11.  Using SD GlucoNavii® Link0.3 NFC  Test StripsChapter 2 : Control Solution Test1.  Performing a Control Solution Test           2.  Troubleshooting Control Solution TestChapter 3 : Testing Your Blood Glucose1.  Getting a Drop of Blood2.  Performing a Blood Glucose Test3.  Understanding Test Results44666781213141626TABLE OF CONTENTS28293234343638nuGsWUZGumj|GluYWXZW[X^YUGGGY YWXZTW[TX^GGG㝘䟸G\aXYa[X
3SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM TABLE OF CONTENTSChapter 4 : Using NFC function1.  Information on NFC function2.  Information on Caution for NFC3.  Using NFC function4.  How to use GlucoNavii App5.  How to use GlucoNavii DMS for PCChapter 5 : Using the Meter Memory1.  Searching Test Results2.  Downloading results to a computerChapter 6 : Maintenance and Troubleshooting1.  Performing a SD Glucose check strip2.  Cleaning the meter3.  Maintenance, Testing and Transportation4.  Cleaning the Lancing Device5.  Screen Messages and Troubleshooting6.  Warnings, Precautions and Limitations Chapter 7 : Product Technical Information1.  System SpecicationsAnnex 1 :  Information for Healthcare ProfessionalsAnnex 2 :  SymbolAnnex 3 :  References404040414243454650515152535455626464666769nuGsWUZGumj|GluYWXZW[X^YUGGGZ YWXZTW[TX^GGG㝘䟸G\aXYa[X
4Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM CHAPTER 1 : Understanding Your New SystemThe SD GlucoNavii® Link0.3 NFC  Blood Glucose Monitoring System1. Before You Start TestingAbout the meter and test strips t Carefully  read  and  follow  the  instructions  in  the  User Instruction  Guide and Package Inserts  for the test  strips and  SD Glucose control  solution. It  is  very  important  to follow  the  instructions  in  order  to  prevent  an  incorrect result or improper treatment. t The meter, test strips, and SD Glucose control solution are only for use outside the body (in vitro). t Your  new  meter  is  designed  for  testing  fresh  capillary whole  blood  samples  (for  example,  blood  from  your ngertip,  palm,  upper  arm,  or  forearm)  or  fresh  venous blood. t Only  use  SD  GlucoNavii®  Link0.3  test  strips.  Other  test strips will give inaccurate results or E-1 error message.t Do not use the SD GlucoNavii® Link0.3 NFC blood glucose monitoring  system  for  testing  of  serum  or  plasma  or arterial blood.t Inspect the container of test strips before using them for the rst time. If you see any damage to the container cap or if anything prevents the cap from closing properly, do not use the test strips. Contact SD Biosensor, Inc. Damaged test strips can cause inaccurate results, which could lead to improper treatment. About your new meter t Set the beep, date, time, hypo warning, post-meal alarm and alarm on your meter before you begin testing. t SD GlucoNavii® Link0.3 NFC system has been found to be accurate at altitudes up to 12,388 feet. (3,776 meters) nuGsWUZGumj|GluYWXZW[X^YUGGG[ YWXZTW[TX^GGG㝘䟸G\aXYa[X
5Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM t Keep the meter and testing supplies away from small children. t The battery door, test strips, lancets, protective disks, and control solution cap are choking hazards. t Do not eat the test strips. t Do not swallow or inject SD Glucose control solution, or use control solutions for any purpose. CAUTIONImportant Informationt Dehydration: Severe dehydration resulting from excessive water loss may  cause false low  results. If you believe  you are suering from severe dehydration, consult a healthcare professional immediately. t Low glucose results: If  your test  result is  lower than 70 mg/dL or is shown as Lo, it may mean hypoglycemia(low blood  glucose).  This  may  require  immediate  treatment according to your healthcare professional’s recommenda-tions. Although this result could be due to a test error, it is safer to treat rst, and then repeat the test. t High glucose results: If your test result is greater than 180 mg/dL or is shown as HI, it may mean hyperglycemia(high blood glucose). If you do not have symptoms, rst repeat the test. Your healthcare professional can work with you to  decide  what  actions,  if  any,  you  should  take  if  you continue to get  results higher than  180 mg/dL or  if you have symptoms. t Repeated  unexpected  results:  If  you  continue  to  get unexpected  results,  check  your  system  with  control solution. See Checking the System with Control Solution. If you are experiencing symptoms that are not consistent with  your  blood  glucose  results  and  you  have  followed all  instructions  in  this  User  Instruction  Guide,  call  your nuGsWUZGumj|GluYWXZW[X^YUGGG\ YWXZTW[TX^GGG㝘䟸G\aXYa[X
6Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM healthcare professional. Never ignore symptoms or make signicant  changes  to  your  diabetes  control  program without speaking to your healthcare professional. t Consult your physician to determine if it is appropriate for your child to be taught how to use the meter system or any other medical products.2.     Special Information for Healthcare Providers and Caregiverst  Do  not  use  this  device  to  measure  blood  glucose  in people  who  are  experiencing  cardiovascular  collapse (severe shock) or decreased peripheral blood ow. t Hematocrit:  A  hematocrit  (percentage  of  your  blood that is red blood cells) that is over 60% or below 20%  can cause false results. 3.  Indication for use (Purpose of the devices)Your new SD GlucoNavii® Link0.3 NFC meter and accessories work together to measure the amount of glucose (sugar) in your blood.  Your SD GlucoNavii® Link0.3 NFC blood glucose monitoring system  is  indicated  for  monitoring  glucose  in  fresh capillary  whole  blood  or  fresh  venous  blood.  Testing is  done  outside  the  body.  (in  vitro  diagnostic  use)  This system is indicated for home (over-the-counter or OTC) by person with diabetes, or in clinical settings by healthcare professionals,  as  an  aid  to  monitor  the  eectiveness  of diabetes control. This system should not be used for the diagnosis of diabetes.The SD GlucoNavii® Link0.3 NFC blood glucose monitoring system is suitable for self-testing.4.  Product Description and the Principle of the useSD  GlucoNavii®  Link0.3  test  strip  is  designed  with  an electrode  that  measures  glucose  levels.  Glucose  in  the blood  sample  mixes  with  reagent  on  the  test  strip  that nuGsWUZGumj|GluYWXZW[X^YUGGG] YWXZTW[TX^GGG㝘䟸G\aXYa[X
7Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM cause a small electric current. The amount of current that is created depends on how much glucose is in the blood.SD GlucoNavii® Link0.3  NFC meter measures the current that  is  created  and  converts  the  measurement  to  the amount of glucose that is in the blood.The blood glucose result is displayed on the meter’s LCD display.By  touching  a  drop  of  blood  to  the  tip  of  the  SD GlucoNavii® Link0.3 test strip, the strip’s reaction chamber automatically  draws  the  blood  into  the  strip  through capillary action. When the chamber is full, SD GlucoNavii® Link0.3  NFC  meter  start  to  measure  the  blood  glucose level.  It  is  a  simple  and  practical  system  for  the  daily monitoring of your blood glucose level.5.  The Complete  GlucoNavii® Link0.3 NFC  BGMSThe system includes: t SD GlucoNavii® Link0.3 NFC  Meter t SD Glucose Check strip  t 3V battery type CR2032t User Instruction Guide t Quick Guidet Carrying Case t Lancing devicet Lancet<Option>t SD GlucoNavii® Link0.3 Test strips t SD GlucoNavii® Link0.3 Package Insertt SD Glucose Control Solutiont SD Glucose Control Solution Package Insertt Self-test Diary t GlucoNavii Application for Android phonet GlucoNavii DMS for PCt NFC Reader/WriternuGsWUZGumj|GluYWXZW[X^YUGGG^ YWXZTW[TX^GGG㝘䟸G\aXYa[X
8Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM DisplayShows blood glucose result, messages, and glucose result stored in memory.Link0.3NFC6. SD GlucoNavii® Link0.3 NFC  MeterArrow ButtonsUse for meter setup and review of memory moving to the right and left.ON/OFF ButtonPress to turn meter ON or OFF.Test Strip SlotInsert test strip here.Battery CoverRemove cover to change battery.Location of NFC functionTap a smartphone or SD NFC R/W for communication.Data portCominucate test results with a personal computer. (If you have software)nuGsWUZGumj|GluYWXZW[X^YUGGG_ YWXZTW[TX^GGG㝘䟸G\aXYa[X
9Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM Indicates Measurement timeIndicates during the meter settingIndicates beep settingWarns when thebattery is low or must be replacedIndicates if environmentaltemperature is exceeded during testingIndicates post-meal or pre-mealTesting dateIndicates a test result stored in memoryUnit of test result Test result and nfc messageDisplaynuGsWUZGumj|GluYWXZW[X^YUGGG` YWXZTW[TX^GGG㝘䟸G\aXYa[Y
10Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM Indicates the average result Test stripTell you when to apply the sample and indicates if you select whole blood for blood reference typeIndicates a controlsolution test resultIndicates alarm settingIndicates hypo warningIndicates S/W communicationnuGsWUZGumj|GluYWXZW[X^YUGGGXW YWXZTW[TX^GGG㝘䟸G\aXYa[Y
11Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 1) Strip Stand-by DisplayAfter  turning  on  the  meter,  the  below  will  be  displayed automatically  to show  the  test  strip  icon  ashing. In  this Strip Stand-by Display, it’s able to enter setting mode of the meter or search the test results.2) Blood Stand-by DisplayIf a test strip is inserted into the meter in either Strip Stand-by  Display  or  turning  o,  the  below  will  be  displayed automatically  to  show  the  appropriate  test  result  after applying  blood sample.  And  if you  pull  o  the test  strip, it will return to Strip Stand-by Display. In this Blood Stand-by Display, the ON/OFF button doesn’t act. But if you need to check the meter or the test strip, you may use a control solution. Then the control solution icon in the left-side of test  strip  icon  will  be  displayed  by  pressing  left  button during 3 seconds.nuGsWUZGumj|GluYWXZW[X^YUGGGXX YWXZTW[TX^GGG㝘䟸G\aXYa[Y
12Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 7.   SD GlucoNavii® Link0.3 Test Strip SD GlucoNavii® Link0.3 NFC System measures the amount of glucose in whole blood. Blood is applied in the Yellow Window (TOP EDGE) of SD GlucoNavii® Link0.3 Test Strip and is  automatically drawn into the  reaction cell where the reaction takes place.  (Top Edge)nuGsWUZGumj|GluYWXZW[X^YUGGGXY YWXZTW[TX^GGG㝘䟸G\aXYa[Y
13Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM SD GlucoNavii® control solutionNFC Reader/Writer 8.  SD GlucoNavii® Link0.3 NFC  Accessories 12Lancing DeviceCap & Comfort dial with puncture depth selectionArmingKnobReleaseButtonCheck Strip  Lancet SD Glucose check strip ElectrodeArmingKnobnuGsWUZGumj|GluYWXZW[X^YUGGGXZ YWXZTW[TX^GGG㝘䟸G\aXYa[Z
14Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 9. Changing the BatteryInserting and replacing the BatteryYour  meter  is  shipped  with  one  3V  battery  type  CR2032 that needs to be inserted before testing. The battery that comes with your meter can be found in the mesh pocket of your  carrying  case. Battery life  will vary depending  on usage, so  always  keep a  spare  on hand. The  meter saves battery power by automatically turning o after 1 minute without inserting a test strip or 3 minutes with a test strip, from non-use. If the meter does automatically shut o, all tests in memory are saved.STEP-1:  Push  the  recessed  plastic  tab  of  the  battery compartment forward to ip and open the battery door.nuGsWUZGumj|GluYWXZW[X^YUGGGX[ YWXZTW[TX^GGG㝘䟸G\aXYa[Z
15Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP-2:  Insert the 3V battery (type CR2032) into the compartment with “+” side facing you.   STEP-3:  Snap battery cover back in place.   STEP-4:  Push the ON/OFF button or insert a strip to start testing.After inserting or replacing the battery, conrm that the time and date are set correctly. If they are not, use the ON/OFF and left/right buttons to reset the meter before testing. See the “10. Meter Set up”. NOTEnuGsWUZGumj|GluYWXZW[X^YUGGGX\ YWXZTW[TX^GGG㝘䟸G\aXYa[[
16Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 10. Meter Set upSTEP-1 : Setting the Audible Beep1.  In  Strip  Stand-by  Display,  if  you  press  the  ON/OFF button  during  3  seconds, the  display  for  setting  the beep will appear, the rst step of the setting mode.2.  Set  the  beep  mode  on  or  o  by  pressing  either the  left  or  the  right  button  and  then  selecting  the preferred  feature  by pressing  the ON/OFF  button.  If you select the beep on feature, a ‘beep’ sound is made at the same time; otherwise, if you select the beep o feature, no sound is made. [ During 3 sec. ]Link0.3[ Left or right button ]Link0.3 Link0.3[ ON/OFF button ]nuGsWUZGumj|GluYWXZW[X^YUGGGX] YWXZTW[TX^GGG㝘䟸G\aXYa[^
17Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP-2: Setting the Hypo warning  1.  After  beep  setting,  the  display  for  setting  the  hypo warning will appear, the second of setting mode.2.  Set the hypo warning mode ‘o’ or the result you want to select among 60, 70, 80 mg/dL(3.3, 3.9, 4.4 mmol/L) by pressing either the left or the right button and then selecting the preferred feature by pressing the ON/OFF button.t You can set the meter to let you know when your result indicates a possible low blood glucose (hypoglycemia). You can also select what blood glucose level you want this indicator to have 60, 70, 80 mg/dL(3.3, 3.9, 4.4 mmol/L).t If your results are lower than selected hypo result, the candy symbol will appear on LCD with a ‘beep’ sound. It is very important to manage your hypoglycemia.NOTEnuGsWUZGumj|GluYWXZW[X^YUGGGX^ YWXZTW[TX^GGG㝘䟸G\aXYa[^
18Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP3: Setting the date and time[ Date Setting ]1.  The  third  step  of  setting  mode  is  the  Date  &  Time setting. After setting the hypo warning, the display for setting Date  & Time will  appear, the  third step  of the setting  mode. Set  the  correct year  by  pressing either the left or the right button and then select the correct year by pressing the ON/OFF button. Your new meter comes with a preset time and date. You may need to change the time to your time zone. Having the right time and date in your meter is important if you use the meter memory. It also helps your healthcare team interpret your results.NOTEnuGsWUZGumj|GluYWXZW[X^YUGGGX_ YWXZTW[TX^GGG㝘䟸G\aXYa[^
19Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM [ Left or right button ]Link0.3 Link0.3[ ON/OFF button ]2.  Next will appear the setting display for month and day format. The  meter  can  display  the  month  and  day  in either  a  Month-Day (m-d)  format or  a  Day-Month  (d-m) format. Set the preferred format on the display by pressing either the left or the right button and select by pressing the ON/OFF button.3.  Set the correct month or day on the display by pressing either the left or the right button and select by pressing the ON/OFF button.nuGsWUZGumj|GluYWXZW[X^YUGGGX` YWXZTW[TX^GGG㝘䟸G\aXYa\W
20Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM [ Time Setting ]1.  Next will appear the display for setting the 12 or 24 Hour clock format. The meter can display the time in either the  12h  format  or  the  24h  format.  Set  the  preferred format on the display by pressing either the left or the right button and select by pressing the ON/OFF button. 2.  Next will appear the setting display for time format. Set the correct hour and minute on the display by pressing either the left or the right button and select the correct time by pressing the ON/OFF button.[ Left or right button ]Link0.3Link0.3[ ON/OFF button ]nuGsWUZGumj|GluYWXZW[X^YUGGGYW YWXZTW[TX^GGG㝘䟸G\aXYa\Z
21Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM [ Left or right button ]Link0.3 Link0.3[ ON/OFF button ]STEP4: Post-meal alarmYou  can  use  the  meter’s  post-meal  alarm  function  to remind you to test your blood glucose after meal.1.  After day  and time  setting, the  display for setting  the post-meal alarm will appear the fourth of setting mode.2.  Set  the  post-meal alarm  mode ‘2h’  or ‘o’  by  pressing either the  left or  the right button and  then select  the preferred feature by pressing the ON/OFF button.  nuGsWUZGumj|GluYWXZW[X^YUGGGYX YWXZTW[TX^GGG㝘䟸G\aXYa\\
22Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM t If you select the post-meal alarm ‘2h’ feature and test with pre-meal mark, the ‘clock symbol’ will appear on result display and the ‘beep’ sound will be made in 2 hours to remind you to test your blood glucose after meal for 1mimute. t If you perform the pre-meal test while the post-meal alarm setting is on, then the post-meal mark will appear automatically on your LCD when you test within following period: from 30min to 130min after your pre-meal test. t If you mark the new test result with a pre-meal mark, the old alarm setting will be ignored and only the new setting will sound in 2 hours.NOTEnuGsWUZGumj|GluYWXZW[X^YUGGGYY YWXZTW[TX^GGG㝘䟸G\aXYa\\
23Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP5: Setting the alarmYou can use the meter’s alarm function to remind you to test your blood glucose.1.  After Post-meal alarm setting the display for setting the alarm will appear, the fth of setting mode.  2.  Set the rst alarm on or o by pressing either the left or the right button and then select the preferred feature by pressing the ON/OFF button.t If you select the alarm o feature, next will appear the Strip Stand-by Display. t If you select the alarm on feature, you can set the alarm up to four times a day at any time you want.NOTE[ Left or right button ]Link0.3 Link0.3[ ON/OFF button ]nuGsWUZGumj|GluYWXZW[X^YUGGGYZ YWXZTW[TX^GGG㝘䟸G\aXYa\_
24Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 3.  If you select the alarm  on feature in rst alarm  mode, the clock will blink. Set the correct time and minute you want to set an alarm on the display by pressing either the left or the right button and then select the preferred feature by pressing the ON/OFF button.4.  If  you nish setting the rst  alarm,  next will  appear  the second alarm setting mode. Set the alarm with the same way as above. [2, 3]5.  You can set the third and fourth alarm mode with the same way as above. [2, 3]If you select the alarm o feature in rst (also second, third and fourth) alarm mode, next will appear the Strip Stand-by Display.NOTE[ Left or right button ]Link0.3 Link0.3[ ON/OFF button ]nuGsWUZGumj|GluYWXZW[X^YUGGGY[ YWXZTW[TX^GGG㝘䟸G\aXZaWY
25Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP6: DATA REVIEW SETTINGThis function is to review the latest test result when inserting the strip into the meter. You can check your latest test result before testing.1.  After alarm setting, display the Data review setting mode. 2.  Set the data review function by pressing the left or right button for selecting the preferred feature.Link0.3Link0.3Link0.3nuGsWUZGumj|GluYWXZW[X^YUGGGY\ YWXZTW[TX^GGG㝘䟸G\aXZaW\
26Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 3.  If you nish data review setting mode, next appear at the strip-stand by display. 11.  Using SD GlucoNavii® Link0.3 Test Strips[ Important Test Strip Information ]t SD GlucoNavii® Link0.3 blood glucose test strip should be used with SD GlucoNavii® Link0.3 NFC meter. Using other glucose test strip can cause inaccurate the result or ‘E-1’ error message.t After removing a test strip from the container, replace the container cap immediately and close it tightly. t Use the test strip within three minutes after you take it out of the container. t Store test strip containers in a cool, dry place at 2-32°C(36-90°F).  Keep  away  from  direct  sunlight  and  heat.  Do  not refrigerate test strips. t Do  not  expose  strips  to  heat,  moisture  or  humidity. Temperatures  outside  the  required  range,  as  well  as moisture and  humidity  (e.g. bathroom,  kitchen,  laundry room, car, or garage) can damage your test strips and lead to inaccurate results. t Store test strips  in their  original container  only to avoid damage or  contamination. Do  not transfer test  strips to any other storage device, and do not store outside of their original container.  t Do not use test strips from any container that is damaged or left open to air. nuGsWUZGumj|GluYWXZW[X^YUGGGY] YWXZTW[TX^GGG㝘䟸G\aXZaW]
27Understanding Your New SystemSD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM t Write the opening date on the container label when you rst  open  it.  Discard  remaining  SD  GlucoNavii®  Link0.3  Test  Strips  after  the  discard  date.  (6  months  after  rst opening from the container.) t SD GlucoNavii® Link0.3 Test Strips are for single use only. Never  reuse  a  test  strip  that  has  had  either  blood  or control solution applied to it. t Avoid getting dirt, food or liquids on the test strip. With clean, dry hands, you may touch the test strip anywhere on its surface. t Do  not  bend,  cut,  or  alter  SD  GlucoNavii®  Link0.3    Test Strip in any way. Do not swallow test strips. The test strip container may contain drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation.CAUTIONnuGsWUZGumj|GluYWXZW[X^YUGGGY^ YWXZTW[TX^GGG㝘䟸G\aXZaW]
Control Solution Test28SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM CHAPTER 2 : Control Solution TestWhy you do control solution test ; t SD  Glucose  control  solution  is  used  to  check  that  the meter and the test strips are working together as a system and that you are performing the test correctly. t It is very important that you do this simple check routinely to make sure you get an accurate result. When you do control solution test ;t You open a new box test strips. t You left the test strip container open or you think your test strips have been damaged. t Your test strips were stored in extreme temperatures and/or humidity. t You want to check the meter and test strips. t You dropped the meter. t Your test result does not agree with how you feel. t You want to check if you are testing correctly. Before you begin ; t Use only SD Glucose control solution. t Check  the  expiration  date  on  the  control  solution container. Record the opening date on the container label. Do Not use after expiration or discard date (date opened plus three months), whichever comes rst. t Control solution, meter and test strips should be at room temperature 18-30°C (64-86°F) before testing with control solution. nuGsWUZGumj|GluYWXZW[X^YUGGGY_ YWXZTW[TX^GGG㝘䟸G\aXZaW]
Control Solution Test29SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM t Shake  the  container,  discard  the  rst  drop  of  control solution, and wipe o the tip to ensure a proper sample and an accurate result. t Store  SD  Glucose  control  solution  tightly  closed  at temperatures  between  8-30°C  (46-86°F).  Do  Not refrigerate. 1.  Performing  Control Solution TestYou need the meter, a test strip, and control solution Level M or Level H. The control level is printed on the test strip label.For  more  information  how  to  obtain  SD  Glucose  control solution, call at +82-31-300-0400.t Do not swallow SD Glucose control solution; it is not for human consumption. t Do not apply SD Glucose control solution to the skin or eyes as it may cause irritation. CAUTIONA set of Level M and H control solutions is available for purchase. To order control solutions, talk to your pharmacist or medical surgical supply dealers. Your meter is designed to recognize the dierence between Control Solution and blood. The meter automatically stores the test results using a control solution, letting your review them. But the meter does not include them in averages.NOTEnuGsWUZGumj|GluYWXZW[X^YUGGGY` YWXZTW[TX^GGG㝘䟸G\aXZaW]
Control Solution Test30SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM STEP-1:1)  Remove  a  new  test  strip  from  container.  Be  sure  to tightly replace container cap after removing test strip. 2) Insert a test strip (yellow window printed  ‘Link0.3’ facing up) into test strip slot. The meter turns on automatically.STEP-2:1)  Press the left button for 3 seconds to check the testing system using a control solution in Blood Stand-by Display. If you don’t want a control solution test, press the left button again.2)   Shake  the  control  solution container  and  discard  the rst  drop  of  solution.  Gently  squeeze  the  container to form one small drop. Bring the drop to the edge of the strip, and allow the strip to automatically draw the control solution into the yellow window. When control solution is  applied to the test strip, the  meter counts down from 5 to 1 second on the display. Tightly replace the cap on control solution. Link0.3[ Left button ]Link0.3nuGsWUZGumj|GluYWXZW[X^YUGGGZW YWXZTW[TX^GGG㝘䟸G\aXZaW^
Control Solution Test31SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 3)  The control solution result appears on the screen in just 5 seconds. 4)  Compare control solution result with the range printed on the test strip container.   If the results are not within the control range printed on the test strip container, then the meter and strips may not be  working  properly. Repeat  the control solution test.5)  Remove  the  used  test  strip  for  control  solution  from the meter and discard it.mg/dLmmol/LLink0.3NFCNOTE The control solution range printed on the test strip container is for SD GlucoNavii® Control Solution only. It is not a recommended range for your blood glucose level. [This is an example. Refer to the ranges on your test strip container.]Control RangeLevel M Level H90-140 mg/dL 170-240 mg/dL5.0-7.8 mmol/L 9.4-13.3 mmol/Lmg/dLmmol/L[Example]nuGsWUZGumj|GluYWXZW[X^YUGGGZX YWXZTW[TX^GGG㝘䟸G\aXZaW^
Control Solution Test32SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM Check ActionDid you do the test in control solution mode? Did you see “control solution container icon” on the screen with the result? If not, do the test again. Insert a test strip; Press the left button for 3 seconds in Blood Stand-by Display to display a control solution container icon. Have the test strips and/or control solution expired? Make sure that test strips and control solutions are not past expiration date. This date is shown the container/bottle. Make sure the expiration date of both a test strip and a control solution.(test strip : 6 months, control solution : 3months)Were control solutions at room temperature (18-30°C, 64-86°F) when used? If not, retest with new bottle of control solution, or warm up/cool down to room temperature.(18-30°C, 64-86°F) 2. Troubleshooting Control Solution Test nuGsWUZGumj|GluYWXZW[X^YUGGGZY YWXZTW[TX^GGG㝘䟸G\aXZaW^
Control Solution Test33SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM Check ActionDid you insert test strip rmly into meter? Make sure test strip is inserted into the test strip slot until it will go on further.Did you follow the procedure correctly? Read again “Chapter 2 : Control Solution Test” (pages 28-33) and retest. Were test strips stored correctly? (at 2-32°C, 36-90°F) Was the bottle cap replaced immediately after removing a test strip? If not, retest with a new container of test strips. Is the meter damaged? Does it show an error message?If yes, contact SD Biosensor, Inc. at +82-31-300-0400.Is the control result outside the acceptable range(printed on your test strip container)?Repeat the test. If you get the same results, do not use your meter and test strip until you solve the problem. If you still have problem, call SD Biosensor, Inc. at +82-31-300-0400.nuGsWUZGumj|GluYWXZW[X^YUGGGZZ YWXZTW[TX^GGG㝘䟸G\aXZaW_
34Testing Your Blood Sugar 34SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM CHAPTER 3 : Testing Your Blood Glucose1.  Getting a Drop of Blood 1)  Wash your  hands in  warm, soapy  water.  Rinse  well and dry completely. Warming ngers can increase blood ow. 2)  Turn the lancet insert cap counterclockwise to remove it, insert the lancet into the lancing device holder and push down rmly until it is fully seated. Twist the lancet protective disk until it separates from the lancet. 3)  Replace the cap  and turn it  clockwise, until it  is snug. Adjust  the  puncture  depth  setting  by  turning  the comfort dial. The dial has 1 to 5 steps, and the higher the  step  number,  the  stronger  the  blood  sampling pressure on the puncture site.   The  comport  tip  oers  5  dierent  levels  of  skin penetration. t 1-2 : for soft or thin skin t 3 : for average skin t 4-5 : for thick or callused skin121212nuGsWUZGumj|GluYWXZW[X^YUGGGZ[ YWXZTW[TX^GGG㝘䟸G\aXZaW_
35Testing Your Blood Sugar 35SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM 4)  After cocking the lancing device back, hold the lancing device rmly against the side of nger and then press the release button.1212t A lancet should only be used once. Do not share used lancets with another person. To prevent possible infection, a used lancet should not be touched by another person. t Used lancets in the regular trash can be dangerous. We recommend that you throw out the used lancets in sharps containers or test strip vials. Please be sure to save the cap so that the lancets cannot spill out of the container into the trash.CAUTIONnuGsWUZGumj|GluYWXZW[X^YUGGGZ\ YWXZTW[TX^GGG㝘䟸G\aXZaW`

Navigation menu