 Basic function




Appearance introduction
Input method
Charging mode
Use of application center
 Data collection
 Barcode scanning (1D、2D)
 RFID(HF、UHF)
 Wireless communication
 WIFI
 IR
 Bluetooth
Basic function
Hard keyboard introduction
Direction keys
Side keys, using as scan key
and three keys to restart PDA
Scan keys
With the blue function key to
adjust the volume and screen
brightness
Blue function
Orange function key
key
On/off key
Press and hold
the key for 2s
Delete key
Shift key , using for
change case
Number、letter complex keys
Enter
With the blue key to set Fn function
Point
0/space
With orange key can use as symbol key
Hard keyboard introduction
1.Restart :data in RAM is lost, but the install won’t be lost
Any one of
the two
Press the three keys together and then
release. You can restart the machine.
Any one of the
side keys
2. Recover the device to default setting:all the programs and data will be cleared except
the data on user’s memory space.
Refer to the guidebook of default setting for details.
Hard keyboard introduction
3、Use of orange key
The key is an input method switch key, press the orange function key, enter the text input
Before pressing
the orange key
After pressing the
key
After pressing 1
key
After pressing 2
key
Hard keyboard
3、Blue function key usage
The key function is Fn, press blue key and then press 1,run F1.
Use the arrow keys with the left and right key to adjust the volume up and
down keys to adjust the screen
Fn setting :Click into Set-System, click
Pressing F1 will execute barcode
Blank means no hotkey
Scanning can set the hotkey
Input
1、Input
There are three input
methods,such as keyboard\soft
keyboard\hard keyboard
keyboard
Soft keyboard
Battery indicator and charging
1、Indicator
Full
Not full, double click the icon
to display the power
Low power
Charging
2、Charging methods
End plug charging charging time:2-3h
Base charging
charging time:2-3h
Portable charger charging time:4-5h
3、Cradle introduction
When the PDA is being charged, PDA’s red light means
charging, green light means full.
When the battery is being charged in cradle compartment,
the middle light will turn the red to green light.
Attention:
1.The three light-emitting diodes in cradle from left to
right are power entry、 charging indicator、 USB data
connection indicator.
2.When the battery will charge fully, the charging LED
will turn out for a short time.
RS232
USB1.1
Both PDA and battery
charging
Optional BT function
AppCenter
Open the AppCenter ( path: Start-Programs- AppCenter )
You can set the AppCenter. Default password is " seuic "
Enter into
management
setting
Enter the
password
Display the opened
software
Software authority
management
Modify the
password
Set boot from
the start
Data capture
1D scanner parameters
•
•
•
•
•
•
•
•
•
•
•
TYPE:
MOTO(symbol)-SE955
Optical Resolution: 0.004in(4mil)
Scan Rate: 92scans/second to 116scans/second
Scan Distance: 2cm to 100cm
Rotation Angle: 5in±35°(100%UPC)
Tilt Angle: 5in±65°(100%UPC)
Skew Tolerance: ±50°( 100%UPC)
Ambient Light: Natural light:10,000ft. Candles(107,640Lux)
Artificial light:450ft.candles(4,844Lux)
Scan Angle: 47°± 3°(standard)
Laser Power: 1.7MW±0.2MW(standard)
Support:
UPC-A,UPC-E,UPC-E1,EAN-8,EAN-13,Bookland
EAN , Code-128,UCC/EAN-128,MSI,ISBT 128,
Code 39, Trioptic Code 39,Code 93,Code 11,
Codabar, ITF-14,RSS-14。
1D Scanner
Settings
Click this will
close the 1D scanner
Hide the 1D
scanner
1D Scanner
Setting barcode type
Suggest not modify
1D Scanner
Set remind mode
Set barcode show
mode
Set run program at startup
2D Scanner
Enter into “AppCenter”,click
Start the 2D scanner
2D Scanner
Clean the barcode information in
the screen
Image capture function can
capture black and white pictures
Recover to default settings
Save the modified settings
Attention: each time modify
Parameters, click saving
Hide the 2D software
Exit
2D Scanner
Set automatic and auto scan delay
Set the time interval
If you want to output the code to txt
or excel, you need to choose Clipboard or
Simulate Key
2D Scanner
1、Set scaner light
general select Both
aimer And LED
2、If code is white, background is
black. Please select Enable
Colour Reverse
3、Scan mode :general
" standard ".
4、Set the scan prompt
5、Display code
information
Cancel all display
information
Select all display
information
Reset Statisitcs can
clear it
6、Barcode
type open or
close
7、Barcode
configuration
recovery
8、Hide the 2D
software
RFID—HF module parameters
HF (Mstar):
 Read and write tag:support ISO15693、ISO14443A/B(Without encryption
protocol)、ISO18000-3 protocol
 Read and write frequency:13.56MHz
 Read and write distance: 0-6cm (write distance slightly less than read)
HF (M1):
 Read and write tag :ISO14443A(encryption protocol)(Mifare one S50,S70
and other compatible tag)
 Read and write frequency :13.56MHz
 Read and write distance: 0-6cm (write distance slightly less than read)
RFID—HF ( Mstar usage)
Top back space is
read and write area
1、Enter into AppCenter then
click
2、Click " Connect" then display
" Connect success ".
3、Click " R/W Test " then display
" R/W Test OK ".
RFID—HF ( Mstar usage)
4、Click " Tag Read " enter into read
and write operation
RFID—HF ( Mstar usage)
5、Click " Read " can read tag number、
protocol type、read times, as the
right figure
6、Click " READBLOCK " can read data
in the tag
7、Click " WRITEBLOCK " can write data
in the tag
Attention: this is just a demo software
RFID—HF ( M1 usage)
Top back space is
read and write area
1、Enter into " AppCenter ", click
start the software
2、Clicking “ReadID” can read tag
number
3、Select “Section” and “Block” ,click
“ReadCardData”
4、Clicking “WriteCardData” can write
data in the tag
Attention:Not
every section nor
block can read and
write,for example
section 0 and block
0 can only read
RFID—UHF(common) module
parameter





Read and write tag :support ISO18000-6C、EPC CLASS1G2 protocol
Read and write frequency :902-928MHz
Transmit power:20-26dBm (adjustable)
Read and write distance :0-150cm (write distance slightly less than read)
Multiple tag read:support
Read and write optimum position:45°
RFID—UHF(common)
module
1、Enter into “ AppCenter” ,
click
2、Click " Start_List" can read tag
number、read times, as the right
figure
3、Click "Stop_List", then click
“Read Card” can read the data in
tag
Power setting:
20-26dBm
Address setting:
00 RESERVED
01 EPC
10 TID
11 USER
4、Click "WriteCard " can write data
in tag
Reading many tags,
select the option
Attention :This is just a demo software.
Wireless communication
Wireless technical parameters
WLAN--------WiFi
standard:IEEE802.11b/g
Data rate :802.11b 11Mbps
802.11g 54Mbps
Frequency range: 2.4/2.5GHz
safety: WEP、TKIP、LEAP、PEAP、EAP-TLS、
WPA、WPA2、AES
WPAN--------Bluetooth V2.0+EDR
Data rate:2Mbps
frequency:2.4GHz
standard:IEEE802.15.1
WiFi
1、Open hardware:Enter into “Wireless Manager”,
if display “Disable”, means hardware is
open.If display “Enable”, click it to open
the hardware.
Attention:You don’t need to do the operation
next time you start the PDA.
WiFi
2、Set IP address:If you need to set
fixed IP,enter into “Control Panel” ,
click “Network and Dial-up connections”,
click “WIFI”.
Attention:You don’t need to do the
operation next time you start the PDA.
WiFi
3、Connect a network:Double click the
red circle, click “Wireless information” .
Double click the network you want to
Connect, and set the net parameters
Connect a network ok
WiFi
4、Wi-Fi Manager :click red circle icon
,start the Wifi manager
Display the
current state and
parameters
WIFI icon means:
No WiFi module。
WIFI module disable
No AP single around
There is single around,but not connection
PDA has connected with AP
WiFi
5、Ping test:click“ping” ,click “Start”
will do the Ping operation.
The more data lost,the worse performance
single strength
Attention: Some gateway and AP can’t allow
to ping operation.
WiFi
6、WIFI Config :Set Power Save/Roam
Trigger/Roam Delta/Roam Period
Power Save:Set power save mode,the more power
saving,the worse performance
Roam Trigger:Setting roaming switching values
Infrared(power not control in
old version)
1、Click“ ”-“Run”,input “ cechat”,click OK
2、Serial Port select COM9,click “file” -“settings”,
set the communication protocol. The Baud Rate:1200
or2400.The port communication protocolmust the same
as the IR device settings.As the below figure
Set parameters as you need
Infrared(power control in new
version)
The latest infrared machine is controlled by power in receiving data.
So we need two infrared machines to test infrared
communication ,which need users to write a demo programe.
The development method of infrared is as follows
on():open the power control
off():close the power control
SetRecvState():set infrared to receive
SetSendState():set infrared to send
Bluetooth function
1、Open hardware:Enter into “Wireless Manager”, if display Disable”, means
hardware is open.If display “Enable”, click it to open the hardware.
Attention:You don’t need to do the operation next time you start the PDA.
Bluetooth function
2、Enter into Windows file, start the
PrintUI software, just as the right
Figure. Attention: just start one PrintUI
Bluetooth function
3、Connect other bluetooth device
Click “Inquiry”, other bluetooth devices
around will display in the text box.Select
one bluetooth device,click OK
Attention:The inquiry is over when
the top left corner appears "Print
UI",and during inquirying,don't do
other operations.
Inquirying
Bluetooth function
4、Connect bluetooth device
You need to input the Select
Channel number
Connect successful
Bluetooth function
5、send and receive data:
You can send and receive data by using
cechat.
You should copy the cechat software into
PDA,then start cechat.Serial Port select
COM3.Then you can send and receive data.
Or:by below pathway:
Start-run input”cechat”,then
enter.
Start Bluetooth in AppCenter
1.Enter into application management, choose the third party
program management.
2.Click “add” button.
3.Look for “printui”in windows files, click ok.
4.Choose “show on the desk”, click ok.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Thank you!
Tel:86-25-52261298
Fax:86-25-52261298-8858
URL:www.seuic.com
Hotline:400-777-0876
Service mailbox:AUTOID6@seuic.com
Postal:210006
Address: No 23. Wenzhu Road. Yuhuatai
District. Nanjing. China(210012)
Technical support mail:zoujianjun@seuic.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:12:18 19:19:20+08:00
Modify Date                     : 2014:12:21 14:48:54+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2014:12:21 14:48:54+08:00
Producer                        : doPDF Ver 7.3 Build 391 (Windows XP Professional Edition  (SP 3) - Version: 5.1.2600 (x86))
Format                          : application/pdf
Document ID                     : uuid:0863f705-ed05-42d1-b0ae-20eb43b13359
Instance ID                     : uuid:b9b66688-8b01-4c06-8847-90c876c9b028
Page Layout                     : OneColumn
Page Mode                       : UseNone
Page Count                      : 45
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AC68-AUTOID6

Navigation menu