SEUIC Technologies AUTOID6 AUTOID6 User Manual
Jiangsu SEUIC Technology Co.,Ltd AUTOID6 Users Manual
Users Manual
Catalogue Basic function Appearance introduction Input method Charging mode Use of application center Data collection Barcode scanning (1D、2D) RFID(HF、UHF) Wireless communication WIFI IR Bluetooth Basic function Hard keyboard introduction Direction keys Side keys, using as scan key and three keys to restart PDA Scan keys With the blue function key to adjust the volume and screen brightness Blue function Orange function key key On/off key Press and hold the key for 2s Delete key Shift key , using for change case Number、letter complex keys Enter With the blue key to set Fn function Point 0/space With orange key can use as symbol key Hard keyboard introduction 1.Restart :data in RAM is lost, but the install won’t be lost Any one of the two Press the three keys together and then release. You can restart the machine. Any one of the side keys 2. Recover the device to default setting:all the programs and data will be cleared except the data on user’s memory space. Refer to the guidebook of default setting for details. Hard keyboard introduction 3、Use of orange key The key is an input method switch key, press the orange function key, enter the text input Before pressing the orange key After pressing the key After pressing 1 key After pressing 2 key Hard keyboard 3、Blue function key usage The key function is Fn, press blue key and then press 1,run F1. Use the arrow keys with the left and right key to adjust the volume up and down keys to adjust the screen Fn setting :Click into Set-System, click Pressing F1 will execute barcode Blank means no hotkey Scanning can set the hotkey Input 1、Input There are three input methods,such as keyboard\soft keyboard\hard keyboard keyboard Soft keyboard Battery indicator and charging 1、Indicator Full Not full, double click the icon to display the power Low power Charging 2、Charging methods End plug charging charging time:2-3h Base charging charging time:2-3h Portable charger charging time:4-5h 3、Cradle introduction When the PDA is being charged, PDA’s red light means charging, green light means full. When the battery is being charged in cradle compartment, the middle light will turn the red to green light. Attention: 1.The three light-emitting diodes in cradle from left to right are power entry、 charging indicator、 USB data connection indicator. 2.When the battery will charge fully, the charging LED will turn out for a short time. RS232 USB1.1 Both PDA and battery charging Optional BT function AppCenter Open the AppCenter ( path: Start-Programs- AppCenter ) You can set the AppCenter. Default password is " seuic " Enter into management setting Enter the password Display the opened software Software authority management Modify the password Set boot from the start Data capture 1D scanner parameters • • • • • • • • • • • TYPE: MOTO(symbol)-SE955 Optical Resolution: 0.004in(4mil) Scan Rate: 92scans/second to 116scans/second Scan Distance: 2cm to 100cm Rotation Angle: 5in±35°(100%UPC) Tilt Angle: 5in±65°(100%UPC) Skew Tolerance: ±50°( 100%UPC) Ambient Light: Natural light:10,000ft. Candles(107,640Lux) Artificial light:450ft.candles(4,844Lux) Scan Angle: 47°± 3°(standard) Laser Power: 1.7MW±0.2MW(standard) Support: UPC-A,UPC-E,UPC-E1,EAN-8,EAN-13,Bookland EAN , Code-128,UCC/EAN-128,MSI,ISBT 128, Code 39, Trioptic Code 39,Code 93,Code 11, Codabar, ITF-14,RSS-14。 1D Scanner Settings Click this will close the 1D scanner Hide the 1D scanner 1D Scanner Setting barcode type Suggest not modify 1D Scanner Set remind mode Set barcode show mode Set run program at startup 2D Scanner Enter into “AppCenter”,click Start the 2D scanner 2D Scanner Clean the barcode information in the screen Image capture function can capture black and white pictures Recover to default settings Save the modified settings Attention: each time modify Parameters, click saving Hide the 2D software Exit 2D Scanner Set automatic and auto scan delay Set the time interval If you want to output the code to txt or excel, you need to choose Clipboard or Simulate Key 2D Scanner 1、Set scaner light general select Both aimer And LED 2、If code is white, background is black. Please select Enable Colour Reverse 3、Scan mode :general " standard ". 4、Set the scan prompt 5、Display code information Cancel all display information Select all display information Reset Statisitcs can clear it 6、Barcode type open or close 7、Barcode configuration recovery 8、Hide the 2D software RFID—HF module parameters HF (Mstar): Read and write tag:support ISO15693、ISO14443A/B(Without encryption protocol)、ISO18000-3 protocol Read and write frequency:13.56MHz Read and write distance: 0-6cm (write distance slightly less than read) HF (M1): Read and write tag :ISO14443A(encryption protocol)(Mifare one S50,S70 and other compatible tag) Read and write frequency :13.56MHz Read and write distance: 0-6cm (write distance slightly less than read) RFID—HF ( Mstar usage) Top back space is read and write area 1、Enter into AppCenter then click 2、Click " Connect" then display " Connect success ". 3、Click " R/W Test " then display " R/W Test OK ". RFID—HF ( Mstar usage) 4、Click " Tag Read " enter into read and write operation RFID—HF ( Mstar usage) 5、Click " Read " can read tag number、 protocol type、read times, as the right figure 6、Click " READBLOCK " can read data in the tag 7、Click " WRITEBLOCK " can write data in the tag Attention: this is just a demo software RFID—HF ( M1 usage) Top back space is read and write area 1、Enter into " AppCenter ", click start the software 2、Clicking “ReadID” can read tag number 3、Select “Section” and “Block” ,click “ReadCardData” 4、Clicking “WriteCardData” can write data in the tag Attention:Not every section nor block can read and write,for example section 0 and block 0 can only read RFID—UHF(common) module parameter Read and write tag :support ISO18000-6C、EPC CLASS1G2 protocol Read and write frequency :902-928MHz Transmit power:20-26dBm (adjustable) Read and write distance :0-150cm (write distance slightly less than read) Multiple tag read:support Read and write optimum position:45° RFID—UHF(common) module 1、Enter into “ AppCenter” , click 2、Click " Start_List" can read tag number、read times, as the right figure 3、Click "Stop_List", then click “Read Card” can read the data in tag Power setting: 20-26dBm Address setting: 00 RESERVED 01 EPC 10 TID 11 USER 4、Click "WriteCard " can write data in tag Reading many tags, select the option Attention :This is just a demo software. Wireless communication Wireless technical parameters WLAN--------WiFi standard:IEEE802.11b/g Data rate :802.11b 11Mbps 802.11g 54Mbps Frequency range: 2.4/2.5GHz safety: WEP、TKIP、LEAP、PEAP、EAP-TLS、 WPA、WPA2、AES WPAN--------Bluetooth V2.0+EDR Data rate:2Mbps frequency:2.4GHz standard:IEEE802.15.1 WiFi 1、Open hardware:Enter into “Wireless Manager”, if display “Disable”, means hardware is open.If display “Enable”, click it to open the hardware. Attention:You don’t need to do the operation next time you start the PDA. WiFi 2、Set IP address:If you need to set fixed IP,enter into “Control Panel” , click “Network and Dial-up connections”, click “WIFI”. Attention:You don’t need to do the operation next time you start the PDA. WiFi 3、Connect a network:Double click the red circle, click “Wireless information” . Double click the network you want to Connect, and set the net parameters Connect a network ok WiFi 4、Wi-Fi Manager :click red circle icon ,start the Wifi manager Display the current state and parameters WIFI icon means: No WiFi module。 WIFI module disable No AP single around There is single around,but not connection PDA has connected with AP WiFi 5、Ping test:click“ping” ,click “Start” will do the Ping operation. The more data lost,the worse performance single strength Attention: Some gateway and AP can’t allow to ping operation. WiFi 6、WIFI Config :Set Power Save/Roam Trigger/Roam Delta/Roam Period Power Save:Set power save mode,the more power saving,the worse performance Roam Trigger:Setting roaming switching values Infrared(power not control in old version) 1、Click“ ”-“Run”,input “ cechat”,click OK 2、Serial Port select COM9,click “file” -“settings”, set the communication protocol. The Baud Rate:1200 or2400.The port communication protocolmust the same as the IR device settings.As the below figure Set parameters as you need Infrared(power control in new version) The latest infrared machine is controlled by power in receiving data. So we need two infrared machines to test infrared communication ,which need users to write a demo programe. The development method of infrared is as follows on():open the power control off():close the power control SetRecvState():set infrared to receive SetSendState():set infrared to send Bluetooth function 1、Open hardware:Enter into “Wireless Manager”, if display Disable”, means hardware is open.If display “Enable”, click it to open the hardware. Attention:You don’t need to do the operation next time you start the PDA. Bluetooth function 2、Enter into Windows file, start the PrintUI software, just as the right Figure. Attention: just start one PrintUI Bluetooth function 3、Connect other bluetooth device Click “Inquiry”, other bluetooth devices around will display in the text box.Select one bluetooth device,click OK Attention:The inquiry is over when the top left corner appears "Print UI",and during inquirying,don't do other operations. Inquirying Bluetooth function 4、Connect bluetooth device You need to input the Select Channel number Connect successful Bluetooth function 5、send and receive data: You can send and receive data by using cechat. You should copy the cechat software into PDA,then start cechat.Serial Port select COM3.Then you can send and receive data. Or:by below pathway: Start-run input”cechat”,then enter. Start Bluetooth in AppCenter 1.Enter into application management, choose the third party program management. 2.Click “add” button. 3.Look for “printui”in windows files, click ok. 4.Choose “show on the desk”, click ok. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Thank you! Tel:86-25-52261298 Fax:86-25-52261298-8858 URL:www.seuic.com Hotline:400-777-0876 Service mailbox:AUTOID6@seuic.com Postal:210006 Address: No 23. Wenzhu Road. Yuhuatai District. Nanjing. China(210012) Technical support mail:zoujianjun@seuic.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:12:18 19:19:20+08:00 Modify Date : 2014:12:21 14:48:54+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2014:12:21 14:48:54+08:00 Producer : doPDF Ver 7.3 Build 391 (Windows XP Professional Edition (SP 3) - Version: 5.1.2600 (x86)) Format : application/pdf Document ID : uuid:0863f705-ed05-42d1-b0ae-20eb43b13359 Instance ID : uuid:b9b66688-8b01-4c06-8847-90c876c9b028 Page Layout : OneColumn Page Mode : UseNone Page Count : 45EXIF Metadata provided by EXIF.tools