SOLiD 850C700LTEC RDU MODULE(850C/700LTEC) User Manual

SOLiD, Inc. RDU MODULE(850C/700LTEC)

Users Manual-1

 Confidential & Proprietary                   1/139 SMDR-NH124 Installation and Operation Manual         Document Reference:      Version: V3.0 Document Status:  Release 1 Issue Date:  Jan. 02, 2009 Author:  Kyung Eun Han Department:  R&D Division Team 1     Authorizing Manager:       Youngshin Yeo
 Confidential & Proprietary                   2/139 REVISION HISTORY Version  Issue Date  No. of Pages  Initials  Details of Revision Changes V 1.0  Jan. 02, 2009    Original   V 2.0  Oct. 23. 2009      Add RDU(VHF+UHF) V 3.0  Feb. 04. 2010      Add ADD ON V/UHF ROU                                                            Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.st.co.kr or send email at sjkim@st.co.kr   This manual is produced by Global Business Division Business Team 1. Printed in Korea.
 Confidential & Proprietary                   3/139 Contents Section1 Safety & Certification Notice................................................................... 9 Section2 System Overview ................................................................................... 11 2.1 General overview ......................................................................................... 12 2.2 System overview.......................................................................................... 13 Section3 System Specifications...........................................................................15 3.1 System specifications ................................................................................. 16 3.1.1 Physical Specifications......................................................................... 16 3.1.2 Optic wavelength and Laser power...................................................... 17 3.1.3 Environmental specifications ............................................................... 17 3.1.4 Operating Frequencies range............................................................... 17 3.1.5 Specifications Per band ........................................................................ 18 Section4 System Configuration and Functions.................................................. 23 4.1 BIU (BTS Interface Unit) .............................................................................. 24 4.1.1 Specifications of BIU............................................................................. 24 4.1.2 Block diagram of BIU............................................................................. 25 4.1.3 BIU parts ................................................................................................. 25 4.1.4 Function by unit..................................................................................... 26 4.1.5 Front/rear panels of BIU........................................................................ 31 4.2 ODU (Optic distribution Unit)...................................................................... 33 4.2.1 Specifications of ODU ........................................................................... 34 4.2.2 Block Diagram of ODU .......................................................................... 34 4.2.3 ODU parts ............................................................................................... 35 4.2.4 Function by unit..................................................................................... 36 4.2.5 Front/rear panels of ODU ...................................................................... 37 4.2.6 Interface with BIU .................................................................................. 38 4.3 OEU (Optic Expansion Unit)........................................................................ 39 4.3.1 Specifications of OEU ........................................................................... 40 4.3.2 Block Diagram of OEU........................................................................... 40 4.3.3 OEU parts ............................................................................................... 40 4.3.4 Function by unit..................................................................................... 41 4.3.5 Front/rear panels of OEU ...................................................................... 45 4.4 ROU (Remote Optic Unit) ............................................................................ 46
 Confidential & Proprietary                   4/139 4.4.1 Specifications of ROU ........................................................................... 46 4.4.2 Block Diagram of ROU .......................................................................... 47 4.4.3 ROU parts ............................................................................................... 47 4.4.4 Function by unit..................................................................................... 49 4.4.5 Bottom of ROU....................................................................................... 54 4.5 Add on V/UHF ROU...................................................................................... 56 4.5.1 Specifications of AOR ........................................................................... 56 4.5.2 Block Diagram of AOR .......................................................................... 57 4.5.3 AOR parts ............................................................................................... 57 4.5.4 Function by unit..................................................................................... 58 4.5.5 Rear of AOR............................................................................................ 59 Section5 System Installation & Operation........................................................... 62 5.1 BIU Installation............................................................................................. 63 5.1.1 BIU Shelf Installation............................................................................. 63 5.1.2 BIU Power Cabling................................................................................. 64 5.1.3 RF Interface at BIU................................................................................. 66 5.1.4 MDBU insertion...................................................................................... 70 5.1.5 ODU Interface......................................................................................... 72 5.1.6 Consumption Power of BIU .................................................................. 76 5.2 ODU Installation........................................................................................... 77 5.2.1 ODU Shelf Installation ........................................................................... 77 5.2.2 ODU Power Cabling............................................................................... 77 5.2.3 ODU Optic Cabling................................................................................. 78 5.2.4 Insert DOU to ODU................................................................................. 78 5.2.5 Consumption Power of ODU................................................................. 79 5.3 ROU Installation........................................................................................... 80 5.3.1 ROU Enclosure installation................................................................... 80 5.3.2 ROU Power Cabling............................................................................... 84 5.3.3 Optical Cabling ...................................................................................... 85 5.3.4 GND Terminal Connection .................................................................... 86 5.3.5 Coaxial cable and Antenna Connection .............................................. 86 5.3.6 Insertion of RDU..................................................................................... 86 5.3.7 Consumption of RDU............................................................................. 97 5.4 OEU Installation ........................................................................................... 98 5.4.1 OEU Shelf installation ........................................................................... 98 5.4.2 OEU Power Cabling ............................................................................... 99
 Confidential & Proprietary                   5/139 5.4.3 OEU Optic Cabling............................................................................... 100 5.4.4 Insert DOU to OEU............................................................................... 101 5.4.5 Consumption Power of OEU............................................................... 102 5.5 ADD ON V/UHF ROU Installation .............................................................. 102 5.5.1 AOR Enclosure installation................................................................. 102 5.5.2 AOR Power Cabling............................................................................. 106 5.5.3 GND Terminal Connection .................................................................. 108 5.5.4 Coaxial cable and Antenna Connection ............................................ 108 5.5.5 Consumption Power of AOR............................................................... 108 5.5.6 Interface with existing ROU ................................................................ 109 Section6 Operation...............................................................................................111 6.1 BIU Operation............................................................................................. 112 6.1.1 BIU......................................................................................................... 112 6.1.2 TX Operation at BIU............................................................................. 112 6.1.3 RX Operation at BIU............................................................................. 117 6.1.4 Setting whether to use ROU/OEU at BIU ........................................... 117 6.1.5 ODU Operation at BIU.......................................................................... 119 6.2 ROU Operation........................................................................................... 121 6.2.1 ROU Operation..................................................................................... 121 6.3 OEU Operation ........................................................................................... 127 6.3.1 OEU Operation ..................................................................................... 128 Section7 Additive functions................................................................................ 135 7.1 Shutdown function (TX output shutdown)............................................... 136 7.2 Total Power Limit function (TX Output ALC) ........................................... 136 7.3 Output power automatic setting function (TX Output AGC) .................. 137 7.4 Input power AGC function (TX Input AGC).............................................. 137 7.5 Input power limit function (TX Input ALC) ............................................... 138 7.6 Optic loss compensation .......................................................................... 138
 Confidential & Proprietary                   6/139 Contents of Figure Figure 2.1 – Basic system topology ............................................................... 13 Figure 2.2 – Expansion system topology ....................................................... 14 Figure 4.1 – BIU outer view............................................................................ 24 Figure 4.2 – BIU mounting diagram ............................................................... 25 Figure 4.3 – MDBU Outer Look...................................................................... 28 Figure 4.4 – MDBU Outer Look...................................................................... 29 Figure 4.5 – MCCU Outer Look......................................................................30 Figure 4.6 – MPSU Outer Look...................................................................... 31 Figure 4.7 – BIU front panel Outer Look ........................................................ 32 Figure 4.8 – Rear panel Outer Look............................................................... 33 Figure 4.9 – ODU Outer Look ........................................................................ 34 Figure 4.10 – ODU Inner Look ....................................................................... 35 Figure 4.11 – MDBU Outer Look ....................................................................36 Figure 4.12 – 2Way Divider Outer Look ......................................................... 36 Figure 4.13 – ODU front panel Outer Look .................................................... 37 Figure 4.14 – ODU Rear panel Outer Look.................................................... 37 Figure 4.15 – Interface between BIU and ODU..............................................38 Figure 4.16 – OEU Outer Look.......................................................................39 Figure 4.17 – OEU Inner Look ....................................................................... 41 Figure 4.18 – MDBU Outer Look.................................................................... 42 Figure 4.19 – EWDM Outer Look................................................................... 42 Figure 4.20 – ECPU Outer Look .................................................................... 43 Figure 4.21 – ERFM Outer Look .................................................................... 43
 Confidential & Proprietary                   7/139 Figure 4.22 – ERFM Outer Look .................................................................... 44 Figure 4.23 – OEU front panel Outer Look.....................................................45 Figure 4.24 – Rear panel Outer Look............................................................. 45 Figure 4.25 – ROU Outer Look ...................................................................... 46 Figure 4.26 – ROU Inner Look ....................................................................... 47 Figure 4.27 – RDU Outer Look.......................................................................50 Figure 4.28 – R OPTIC Outer Look................................................................ 51 Figure 4.29 – RCPU Outer Look .................................................................... 52 Figure 4.30 – Multiplexer Outer Look............................................................. 53 Figure 4.31 – ROU Bottom Look.................................................................... 54 Figure 4.32 – AOR Outer Looks..................................................................... 56 Figure 4.33 – AOR Inner Look........................................................................ 57 Figure 4.34 – RDU Outer Look.......................................................................58 Figure 4.35 – AOR Rear Look ........................................................................ 60 Figure 5.1 – RACK Installation....................................................................... 63 Figure 5.2 – 800PS BDA Interface using Circulator ....................................... 69 Figure 5.3 – 800PS BDA Interface using Duplexer ........................................ 69 Figure 5.4 – Optical cable of SC/ACP Type ................................................... 78 Figure 5.5 – How to install ROU..................................................................... 80 Figure 5.6 – Dimension used to install ROU on the WALL............................. 81 Figure 5.7 – Optical cable of SC/ACP Type ................................................. 100 Figure 5.8 – How to install AOR ................................................................... 103 Figure 5.9 – Dimension used to install AOR on the WALL........................... 103 Figure 5.10 – Installation flow diagram when AOR installs on wall .............. 104
 Confidential & Proprietary                   8/139 Figure 5.10 – Installation flow diagram when AOR installs in the rack......... 105 Figure 5.10 – AOR which is installed above of ROU.................................... 109 Figure 5.11 – AOR which is installed under of ROU..................................... 109
 Confidential & Proprietary                   9/139  Section1                                 Safety & Certification Notice
 Confidential & Proprietary                   10/139 “Only qualified personnel are allowed to handle this unit. Read and obey all the warning labels attached in this user manual”      Any personnel involved in installation, operation or service of the SOLiD Technology repeaters must understand and obey the following:  - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.  - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.  - The repeater cover should be (door) securely fastened in open position, e.g. by tying it up, at outdoor work in order to prevent door from slamming due to wind causing bodily harm or damage.  - Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.    - Any repeater, including this repeater, will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed to the signals at the immediate proximity of the repeater and the repeater antennas.    - Due to power dissipation, repeater may reach a very high temperature. Do not operate this unit on or close to flammable materials.    - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives.  - Certification   z  FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24 and 90  z  UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment  z  FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040 -For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible.
 Confidential & Proprietary                   11/139  Section2                                        System Overview            2.1 General overview 2.2 System overview
 Confidential & Proprietary                   12/139 2.1 General overview SMDR-NH124 is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. z Shopping malls z Hotels z Campus areas z Airports z Clinics z Subways z Multi-use stadiums, convention centers, etc.  The system helps improve in-building radio environments in poor condition and make better poor RSSI and Ec/Io. By providing communication services at every corner of buildings, the system enables users to make a call at any site of buildings.   The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods. The SMDR-NH124 system supports communication standards and public interface protocols in worldwide use. z  Frequencies: VHF,UHF, 700MHz, 800MHz,850MHz 900MHz,1900MHz,2100MHz, etc.   z  Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc. z  Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging, etc.  SMDR-NH124 is in modular structure per frequency. To provide desired frequency in a building, all you need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals with one optical cable, the system, in one-body type, does not require additional facilities whenever new frequency is added. The system is featured with the following: z  Flexibiltiy & Scalabiltiy   Support fiber-optic ports up to 39   Clustering multiple-buildings (campus) as one coverage z  Modular structures   Modular frequency upgrade     Plug-in type module   z Multi-Band, Multi Operator
 Confidential & Proprietary                   13/139   Signals with a plurality of service provider transmit simultaneously       Support multi-operator in a band   z  Low OPEX / CAPEX  Compact design   Upgradable design    Easy installation and maintenance   Web Based SNMP or GSM Modem or UDP support (Optional)  2.2 System overview SMDR-NH124 is composed of devices given below. Basically, the system consists of BIU (BTS Interfcace Unit), ODU (Optic distribution Unit) and ROU (Remote Optic Unit). For addition of more ROUs, it has OEU (Optic Expansion Unit).  Figure 2.1 – Basic system topology
 Confidential & Proprietary                   14/139  Figure 2.2 – Expansion system topology    Table 3.1 – System topology Charts System elements  Optical Loss [dBo]  Max. RUs BIU – ODU(DOUx1) – ROU    1~5dBo 4 BIU – ODU(DOUx2) – ROU  1~5dBo 8 BIU – 4ODU(DOUx2) – ROU  1~5dBo 32 BIU – 4ODU(DOUx2)-4OEU(DOUx2) – ROU 1~5dBo 60
 Confidential & Proprietary                   15/139  Section3                                       System Specifications            3.1 System specifications 3.1.1 Physical Specifications 3.1.2 Optic wavelength and Laser power 3.1.3 Environmental specifications 3.1.4 Operating Frequencies range 3.1.5 Specifications Per band
 Confidential & Proprietary                   16/139 3.1 System specifications 3.1.1  Physical Specifications Parameter  BIU  ODU  OEU  ROU  AOR RF Connectors  4 SMA type, female (Per MDBU) 2 SMA type, female  - 1N-type,female 2 SMA Type female External Alarm connector (Dry contacts) Terminal block,3pcs  -  -  -  - Serial Interface connector 1 RS-232 9-pin D-sub, male   1 RS-232 9-pin   D-sub, male 1 RS-232 9-pin  D-sub, male -  Fiber connector  -  8pcs, SC/APC for ROU 1 SC/APC for ODU 8 SC/APC for ROU  1 SC/APC for ODU  - LED Alarm and Status Indicator MDBU Status z Power  On status z ALM status MCPU  z Power  On status z TX Communication  z RX Communication z ALM status MPSU z Power  On status z  DC ALM status DOU1 Status z LD status z PD1/2/3/4 status DOU2 Status z LD status z PD1/2/3/4 status EWDM Status z LD status z PD status DOU1 Status z LD status z PD1/2/3/4 status DOU2 Status z LD status z PD1/2/3/4 status System status z Power  on status z TX Communication  z RX Communication System status z  Power on status z TX1 Communication  z RX1 Communication z TX2 Communication  z RX2 Communication z ALM status  - AC Power  -  -   Normal Range: 120VAC 50/60Hz Operating range 108~132VAC,50/60Hz Same left side DC Power Normal range: -48 VDC Operating range: -40.8 ~ -57.6VDC -  Normal: -48 VDC Operating range: -40.8 ~ -57.6VDC Same to left side Power  consumption 168W (Including ODU 4EA) -  48W (Including DOU2EA)265W (Including RDU 3EA) 78W (VHF/UHF RDU) Enclosure Dimensions 482.6(19”) x 221.5(5U) x 450 482.6(19”) x 43.6(1U) x 450 482.6(19”)    x 88.1(2U) x 450  420 x 530 x 258  482.6(19“) x 258 x 177 Weight[Full Load]  22.25Kg  5.7Kg  9.3Kg  35.45Kg  11Kg
 Confidential & Proprietary                   17/139 3.1.2  Optic wavelength and Laser power Parameter  ODU  OEU  ROU Wavelength  TX: 1310nm RX: 1550nm West optic TX: 1550nm RX: 1310nm East optic TX: 1310nm RX: 1550nm TX: 1550nm RX: 1310nm Output power  3dBm±1dBm to ROU,OEU  3dBm±1dBm to ROU 7dBm±1dBm to ODU  7dBm±1dBm to ODU  3.1.3  Environmental specifications Parameter  BIU, ODU, OEU  ROU/AOR Operating Temperature  -10  to  +50°C  -10 to +50°C Operating Humidity, non condensing  -  5% to 90%  3.1.4  Operating Frequencies range Frequency range Standard   Unit naming  Description  TX(MHz)  RX(MHz) iDEN  700P  Public safety  764 to 776  794 to 806 iDEN  800P  Public safety  851 to 869  806 to 824 Cellular  850C  Cellular  869 to 894  824 to 849 Iden  900I  SMR  929 to 940  896 to 902 Paging  900 PA  Paging  929 to 930  896 to 902 PCS  1900P  PCS  1930 to 1995  1850 to 1915 AWS-1  AWS-1  AWS-1  2110 to 2155  1710 to 1755 -  VHF  Public safety  136 to 174  136 to 174 -  UHF  Public safety  396 to 512  396 to 512 LTE  700LTE  Long Term Evolution  746 to 756  777 to 787
 Confidential & Proprietary                   18/139 3.1.5  Specifications Per band  700MHz Long Term Evolution Typical  Remarks Parameters  TX  RX   Bandwidth 10MHz 10MHz  System ripple  ≤2dB  ≤2dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +23dBm  +0dBm  Total System Gain  43dB  50dB   Gain Control range  18 to 43dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU  700MHz Public safety Typical  Remarks Parameters  TX  RX   Bandwidth 12MHz 12MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +23dBm  +0dBm  Total System Gain  43dB  50dB   Gain Control range  18 to 43dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU
 Confidential & Proprietary                   19/139 800MHz Public safety Typical  Remarks Parameters  TX  RX   Bandwidth 18MHz 18MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +23dBm  +0dBm  Total System Gain  43dB  50dB   Gain Control range  18 to 43dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU  850MHz Cellular Typical  Remarks Parameters  TX  RX   Bandwidth 25MHz 25MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +23dBm  +0dBm  Total System Gain  43dB  50dB   Gain Control range  18 to 43dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU
 Confidential & Proprietary                   20/139 900MHz iDEN & Paging Typical  Remarks Parameters  TX  RX   Bandwidth 12MHz 6MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +23dBm  +0dBm  Total System Gain  43dB  50dB   Gain Control range  18 to 43dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU  1900MHz PCS Typical  Remarks Parameters  TX  RX   Bandwidth 65MHz 65MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +26dBm  +0dBm  Total System Gain  50dB  50dB   Gain Control range  25 to 50dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU
 Confidential & Proprietary                   21/139 1700MHz&2100MHz AWS-1 Typical  Remarks Parameters  TX  RX   Bandwidth 45MHz 45MHz  System ripple  ≤5dB  ≤5dB  Input Power level  -20 to +10dBm  ≤-50dBm  Output power  +30dBm  +0dBm  Total System Gain  50dB  50dB   Gain Control range  25 to 50dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  15dB  1ROU  150MHz VHF Public safety Typical  Remarks Parameters  TX  RX   Bandwidth 38MHz 38MHz 136~174MHz System ripple  ≤5dB  ≤5dB  Input Power level  -15 to +10dBm  ≤-54dBm  Output power  +24dBm  -4dBm  Total System Gain  39dB  50dB   Gain Control range  14 to 39dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  7dB  1ROU
 Confidential & Proprietary                   22/139 450MHz UHF Public safety Typical  Remarks Parameters  TX  RX   Bandwidth 116MHz 116MHz 396~450MHz(54MHz) 450~512MHz(62MHz) Band selection System ripple  ≤5dB  ≤5dB  Input Power level  -15 to +10dBm  ≤-54dBm  Output power  +24dBm  -4dBm  Total System Gain  39dB  50dB   Gain Control range  14 to 39dB  30 to 50dB   IM3 -13dBm -  IP3 - +23dBm  Noise figure  -  7dB  1ROU
 Confidential & Proprietary                   23/139  Section4                               System Configuration and Functions            4.1 BIU (BTS Interface Unit)  4.2 ODU (Optic distribution Unit)  4.3 OEU (Optic Expansion Unit  4.4 ROU (Remote Optic Unit)  4.5  AOR (Add on V/UHF ROU)
 Confidential & Proprietary                   24/139  4.1  BIU (BTS Interface Unit) BIU provides TX signals from BTS or BDA for four ODUs (Optic Distribution Unit). This unit separates RX signals given from ODUs from each other per frequency band.    Figure 4.1 – BIU outer view  4.1.1  Specifications of BIU   Item  Spec.  Remark Size  482.6(19”) x 221.5(5U) x 450 Mm Weight  22.35 Kg Power consumption  168 W  Full Load
 Confidential & Proprietary                   25/139 4.1.2  Block diagram of BIU   4.1.3  BIU parts  Figure 4.2 – BIU mounting diagram  No.  Unit  Description  Remark1 MDBU Main Drive BTS Unit Amplify & adjust downlink RF signal Amplify & adjust uplink RF signal Max 4EA2 MCDU Main Com/Div Unit Combine 4EA downlink signal and divide 4EA signal to ODU Combine 4EA uplink signal and divide 4EA signal to MDBU Support VHF/UHF interface port
 Confidential & Proprietary                   26/139 3 MCPU Main Central Processor Unit Control and monitoring system status Control and monitoring with RS232 Have an access to upper-level network through GSM or Ethernet  4 MPSU  Main Power Supply Unit Input power: DC -48V, Output power: 9V, 6V   5 M/B Mother Board Provide signal interface and power for each unit Provide three ports for dry contact  6  Shelf  19 inch, 5U    4.1.4  Function by unit 1) Main Drive BTS Unit (MDBU) MDBU delivers TX signals of BTS or BDA to related devices and then delivers RX signals of the devices to BTS or BDA. This unit can monitor TX input level. Using input AGC function, it automatically adjusts input ATT. It also has ATT to adjust RX gain. MDBU is varied per frequency band including the following:   In/out RF Port No  Unit naming  Description  TX  RX 1  800PS    Single Band  2 Port  2 Port 2  850C    Single Band  2 Port  2 Port 3  1900P  Single Band  4 Port  4 Port 4  AWS-1  Single Band  4 Port  4 Port 5  800PS+900I+PA  Dual Band  4 Port  4 Port 6  850C+700PS  Dual Band  4 Port  4 Port 7 TBD     8  850C+700LTEC  Dual Band  4 Port  4 Port
 Confidential & Proprietary                   27/139  800PS 800PS+900I+Paging 1900PCS AWS-1
 Confidential & Proprietary                   28/139    Figure 4.3 – MDBU Outer Look   2) Main Com/Div Unit (MCDU) MCDU combines TX signals that are delivered from MDBU per frequency band and delivers the signals to four ODUs. This unit adds signals of FSK modem to the TX signals before sending them to ROU. It also combines RX signals from up to four ODUs and sends them to up to four MDBUs. In this case, the unit extracts signals of FSK modems, which are sent in a combined form with RX signals, and then delivers the signals to MCU. The unit has a port to interface with VHF&UHF signals. It has ATT for input monitoring and input 850C 850C+700PS 850C+700LTEC
 Confidential & Proprietary                   29/139 control.  Figure 4.4 – MDBU Outer Look  VHF+UHF    frequency band including the following:  In/out RF Port No  Unit naming  Description  TX  RX 1  VHF+UHF  Dual Band  1 Port  1 Port   3) Main Central Processor Unit (MCPU) MCPU can inquire and control state of modules that are installed in BIU. This unit can inquire and control state of four ODUs in total. Through communication, it also can inquire and control ROU that is connected with lower parts. In addition, the unit has RS-232C port for serial communication so that it can inquire and control state of devices through PC. On the front panel, it has communication LED indicator to check communication state with ROU. It also has ALM LED indicator to show whether a device gets faulty. For access to upper network, it has a port to insert Ethernet port and GSM modem in it.
 Confidential & Proprietary                   30/139         Figure 4.5 – MCPU Outer Look In the Main Central Processor Unit, a lithium battery is installed for RTC (Real Time Control) function.   CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DIPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS [INSTRUCTION] The equipment and accessories including inner lithium battery are to be disposed of safely after the life span of them and national regulation must be observed. Do not attempt to replace the lithium battery unless service personnel confirmation has first been obtained, to avoid any risk of explosion.
 Confidential & Proprietary                   31/139   4) Main Power Supply Unit (MPSU) MPSU receives -48V of input and outputs +6V and +9V of DC power. On the front panel, this unit has an output test port and it also has DC ALM LED Indicator to show whether output gets faulty.     Figure 4.6 – MPSU Outer Look  4.1.5  Front/rear panels of BIU 1)  Front panel
 Confidential & Proprietary                   32/139  Figure 4.7 – BIU front panel Outer Look  Item  Description 1. MDBU LED  LED to show whether MDBU is installed and gets faulty 2. RF Monitor Port  20Db Coupling compared with TX Input Level 20Db Coupling compared with RX Output Level   3. Alarm LED & Reset  Communication state with devices, alarm status of the system and reset switch 4. NMS(RS-232C port) RS-232C port for communication and diagnosis of devices through PC/laptop 5. NMS(Ethernet port) Ethernet port for upper network This equipment is indoor use and all the communication wirings are limited to inside of the building 6. Pwr Test Port & ALM Output DC power test port and ALM LED to show abnormal state, if any 7. Power switch  Power ON/OFF switch 2) Rear panel
 Confidential & Proprietary                   33/139  Figure 4.8 – Rear panel Outer Look  Item  Description 1. External ALM Port  Input/output terminal for dry contact 2. GSM Modem Port  GSM Modem terminal for upper network (Optional) 3. V/UHF I/O Port  RF signal interface terminal of VHF&UHF 4. ODU I/O Port  RF signal interface terminal for ODU 5. ODU signal Port  Power and signal interface terminal for ODU 6. BTS/BDA I/O Port  Input/output interface terminal of BTS/BDA 7. GND Port  System ground terminal 8. DC Input Port  Input terminal for DC -48V 4.2  ODU (Optic distribution Unit) ODU receives TX RF signals from upper BIU and converts them into optical signals. The optical signals are sent to ROU through optical cables. This unit converts optical signals from ROU into RF signals and sends the converted signals to BIU.   For each shelf of the ODU, up to two DOUs (Donor Optic Unit) can be installed in it. One DOU is supported with four optical ports. Therefore, one ODU can be connected with eight ROUs.  Up to four ODUs can be connected with BIU.
 Confidential & Proprietary                   34/139  Figure 4.9 – ODU Outer Look  4.2.1  Specifications of ODU Item  Spec.  Remark Size  482.6(19”) x 43.6(1U) x 450  Mm Weight  5.7 Kg Power consumption  27 W  Full Load  4.2.2  Block Diagram of ODU
 Confidential & Proprietary                   35/139  4.2.3  ODU parts    Figure 4.10 – ODU Inner Look   No.  Unit  Description  Remark1 DOU DOU Convert TX RF signals into optical signals; Convert RX optical signals into RF signals; Provide up to four optical ports per DOU Max 2ea2 2W 2Way Divider Divide TX RF signals into two; Combine two RX RF signals into one  3 DU  Distribution Unit Distribute power and signals to DOU  4  Shelf  19” rack, 1U     5 Accessories 15PIN DSUB, Male to female 1pcs RF Coaxial Cable Assembly 2pcs
 Confidential & Proprietary                   36/139 4.2.4  Function by unit 1)  Donor Optic Unit (DOU) DOU makes electronic-optical conversion of TX signals and makes optical-electronic conversion of RX signals. With an optic splitter in it, this unit divides optical signals from Laser Diode into four and then distributes them to each optical port. With a total of four Photo Diodes in RX, DOU makes optical-electronic conversion of signals received from each optical port. In addition, the unit is equipped with ATT for optical compensation made in case of optical cable loss. With internal WDM, it uses only one optical cable to be connected with ROU.  Figure 4.11 – MDBU Outer Look 2) 2Way Divider (2W) 2W is equipped with two 2-way splitters in a one-module form and the splitters work for TX/RX signals, respectively. Designed in broadband type, the divider combines and divides 2GHz or higher of signals from FSK modem signals.    Figure 4.12 – 2Way Divider Outer Look
 Confidential & Proprietary                   37/139  4.2.5  Front/rear panels of ODU 1)  Front panel  Figure 4.13 – ODU front panel Outer Look  Item  Description 1,2  LED indicator to check DOU module state to see if it is abnormal  2) Rear panel  Figure 4.14 – ODU Rear panel Outer Look  Item  Description 1. Optic Port  SC/APC optical connector terminal; use one optical cable per ROU. 2. DC I/O Port  Terminal to deliver power and state values   3. RX RF Port  RX RF signal interface terminal 4. TX RF Port  TX RF signal interface terminal
 Confidential & Proprietary                   38/139 4.2.6  Interface with BIU    Figure 4.15 – Interface between BIU and ODU On the top of BIU, up to four ODUs can be stacked. In this case, it is recommended to stack the units at least 1U of an interval between BIU, for heat from BIU may climb up to ODU, which may cause flame.  As seen in the figure below, connect the coaxial cable for TX and another coaxial cable for RX with corresponding ports at the rear of BIU. For power supply and communication, connect 15Pin D-Sub Connector cable with a corresponding port.
 Confidential & Proprietary                   39/139   4.3  OEU (Optic Expansion Unit) OEU is mainly used to remotely deliver signals for Campus clusters. At the upper part, this unit combines with ODU and receives TX optical signals to convert them into RF signals. Then, it regenerates the signals to secure S/N feature and converts them into optical signals. The signals are sent to ROU through optical cables. When it receives RX optical signals from ROU, the unit converts them into RF signals to regenerate the signals and then converts them into optical signals to send them to ODU. In OEU, one shelf can be equipped with up to two DOUs. The DOU is the same as the module used for ODU. Up to two OEUs can be connected with ODU.   Figure 4.16 – OEU Outer Look
 Confidential & Proprietary                   40/139 4.3.1  Specifications of OEU Item  Spec.  Remark Size  482.6(19”) x 88.1(2U) x 450  mm Weight   9.3 Kg Power consumption  48 W  Full Load 4.3.2  Block Diagram of OEU  4.3.3  OEU parts
 Confidential & Proprietary                   41/139 Figure 4.17 – OEU Inner Look   No.  Unit  Description  Remark1 DOU Donor Optic Unit Convert TX RF signals into optical signals; Convert RX optical signals into RF signals; Provide up to four optical ports per DOU Max 2ea2 EWDM Expansion Wavelength Division Multiplexer Convert TX optical signals into RF signals; Convert RX RF signals into optical signals; Compensate for optical cable loss with ODU  3 ECPU Expansion Central Processor Unit Control and monitoring system status Control and monitoring with RS232 Relay state values of ROU to BIU  4 EPSU  Expansion Power Supply Unit Input power: DC -48V, Output power: 9V, 6V  5 ERFM Expansion Radio Frequency Module Regenerate TX signals and transmit FSK modem signals; Regenerate RX signals and receive FSK modem signals  6  Shelf  19” rack, 2U      4.3.4  Function by unit 1)  Donor Optic Unit (DOU) DOU is the same as the module used for ODU.
 Confidential & Proprietary                   42/139  Figure 4.18 – MDBU Outer Look  2) Expansion Wavelength Division Multiplexer(EWDM) EWDM module makes optical-electronic conversion of TX signals and makes electronic-optical conversion of RX signals. With an FSK modem in it, this multiplexer communicates with BIU. It also has ATT for optical compensation to compensate for optical cable loss between ODUs. Furthermore, it has internal WDM, and so, it needs only one optical cable to work with ROU.  Figure 4.19 – EWDM Outer Look 3) Expansion Central Processor Unit(ECPU) ECPU can inquire and control state of modules to be installed into OEU. This unit communicates with upper BIU while communicating with lower ROU. It also acts as communication bridge between BIU and ROU. In addition, the unit has RS-232C port for serial communication, which enables inquiry and control of devices thorugh PC. At the front panel, communication LED indicator indicates communication state with upper BIU and lower ROU. It also has ALM LED indicator to show if a
 Confidential & Proprietary                   43/139 device gets faulty.  Figure 4.20 – ECPU Outer Look 4) Expansion Radio Frequency Module(ERFM) ERFM reconstructs Signal to Noise degraded by optical modules. With an internal FSK modem, this module communicates with ROU.  Figure 4.21 – ERFM Outer Look  5) Expansion Power Supply Unit(EPSU) As DC/DC Converter, EPSU receives -48V of input and provides +9V and +6V of DC power required for OEU.
 Confidential & Proprietary                   44/139  Figure 4.22 – ERFM Outer Look
 Confidential & Proprietary                   45/139 4.3.5  Front/rear panels of OEU 1)  Front panel  Figure 4.23 – OEU front panel Outer Look  Item  Description 1.EWDM LED  LED indicator to check EWDM state to see if it is abnormal 2.DOU LED  LED indicator to check DOU module state to see if it is abnormal 3.System LED and Reset  Communication state with devices, alarm status of the system and reset switch 4. NMS(RS-232C port) RS-232C port for communication and diagnosis of devices through PC/laptop. This equipment is indoor use and all the communication wirings are limited to inside of the building  2) Rear panel  Figure 4.24 – Rear panel Outer Look  Item  Description 1. GND Port  Terminal for system ground 2. DC Input Port  Input terminal for DC -48V 3.power switch  Power ON/OFF switch 4. To/From ODU Optic Port  SC/APC optical connector terminal 5. To/From ROU Optic Port  SC/APC optical connector terminal; use one optical cable per ROU.

Navigation menu