 Confidential & Proprietary                   1/35 HERCULES(Alliance5WRemoteUnit)UserManualSOLiD,Inc.10,9thFloor,SOLiDSpace220Pangyoyeok‐ro,Bundang‐gu,Seongnam‐si,Gyeonggi‐do,Korea393‐400Tel:+82‐31‐627‐6290Fax:+82‐31‐627‐6209
 Confidential & Proprietary                   2/35 REVISIONHISTORYVersionIssueDateNo.ofPages InitialsDetailsofRevisionChangesV1.0July.14,2015Original                      TechnicalSupportSOLiDserialnumbersmustbeavailabletoauthorizetechnicalsupportand/ortoestablishareturnauthorizationfordefectiveunits.Theserialnumbersarelocatedonthebackoftheunit,aswellasontheboxinwhichtheyweredelivered.AdditionalsupportinformationmaybeobtainedbyaccessingtheSOLiDTehcnology,Inc.websiteatwww.solid.co.krorsendemailatkehan@solid.co.krThismanualisproducedbyGlobalBusinessDivisionBusinessTeam1.PrintedinKorea.
 Confidential & Proprietary                   3/35 ContentsSection1 Safety&CertificationNotice ......................................................................... 5 Section2 Introduction ................................................................................................ 9 2.1 Purpose ...........................................................................................................  10 2.2 HERCULES ........................................................................................................  11 2.3 Dimension ....................................................................................................... 12 Section3 SystemInstallation ..................................................................................... 13 3.1 RemoteUnitInstallation ................................................................................... 15 3.1.1 RemoteUnitEnclosureinstallation ................................................................... 15 3.1.2 HowtoexpandADDONROUattheRemoteUnit .............................................. 19 3.1.3 RemoteUnitPowerCabling .............................................................................. 21 3.1.4 RemoteUnitGroundcabling ............................................................................. 22 3.1.5 OpticalCabling ................................................................................................. 24 3.1.6 MountingofMRDU .......................................................................................... 26 3.1.7 HowtomountFANUnit ................................................................................... 28 Section4 SystemSpecifications ................................................................................. 31 4.1 PhysicalSpecifications ......................................................................................  32 4.2 RFperformance ............................................................................................... 33 4.3 Certification ..................................................................................................... 34 
 Confidential & Proprietary                   4/35 ContentsofFigureFigure3.1–RemoteUnitBlockDiagram 오류!  책갈피가 정의되어 있지 않습니다. Figure3.2–InsideofRemoteUnit ........  오류!  책갈피가 정의되어 있지 않습니다. Figure3.3–RemoteUnitDimension ................................................................... 12 Figure4.1–ExteriorofRemoteUnit ................................................................... 15 Figure4.2–DimensionusedtoinstallREMOTEUNITontheWALL ........................ 16 Figure4.3–Proceduresofinstallation ................................................................ 17 Figure4.5–ConnectiondiagrambetweenRemoteUnitandADDONROU(DCtype) ................................................................................................................ 20 Figure4.6–LocationofGroundTerminal ............................................................ 22 Figure4.7–InformationofTerminal  ................................................................... 22 Figure4.8–HowtoinstallGroundTer minal ........................................................ 23 Figure4.9–LocationofOpticalConnector .......................................................... 24 Figure4.10–InformationofOpticalConnector ................................................... 24 Figure4.11–HowtoinstallOpticalCabling ......................................................... 25 Figure4.12–LocationofMRDU ......................................................................... 26 Figure4.13–HowtomountMRDU .................................................................... 27 Figure4.14–HowtomountFANUnit ................................................................. 28 Figure4.15–HowtomountFANUnit ................................................................. 29 
 Confidential & Proprietary                   5/35 Section1 Safety&CertificationNotice
Confidential & Proprietary        6/35 “OnlyqualifiedpersonnelshouldhandletheDASequipment.AnypersoninvolvedininstallationorserviceoftheDASshouldunderstandandfollowthesesafetyguidelines.”‐Obeyallgeneralandregionalsafetyregulationsrelatingtoworkonhighvoltageinstallations,aswellasregulationscoveringcorrectuseoftoolsandpersonalprotectiveequipment.- Thepowersupplyunitinrepeaterscontainsdangerousvoltagelevel,whichcancauseelectricshock.Switchthemainsoffpriortoanyworkinsucharepeater.Anylocalregulationsaretobefollowedwhenservicingrepeaters.‐Topreventelectricalshock,switchthemainpowersupplyoffpriortoworkingwiththeDASSystemorFiberBDA.Neverinstalloruseelectricalequipmentinawetlocationorduringalightningstorm.‐Whenworkingwithunitsoutdoors,makesuretosecurelyfastenthedoororcoverinanopenpositiontopreventthedoorfromslammingshutinwindyconditions.‐Usethisunitonlyforthepurposespecifiedbythemanufacturer.Donotmodifyorfitanysparepartsthatarenotsoldorrecommendedbythemanufacturer.Thiscouldcausefires,electricshockorotherinjuries.‐AnyDASsystemorFiberBDAwillgenerateradio(RF)signalsandcontinuouslyemitRFenergy.Avoidprolongedexposuretotheantennas.SOLiDrecommendsmaintaininga200cmminimumclearancefromtheantennawhilethesystemisoperating.‐Donotoperatethisunitonorclosetoflammablematerials,astheunitmayreachhightemperaturesduetopowerdissipation.‐Donotuseanysolvents,chemicals,orcleaningsolutionscontainingalcohol,ammonia,orabrasivesontheDASequipment.Alcoholmaybeusedtocleanfiberopticcablingendsandconnectors.‐Donotlookintotheendsofanyopticalfiberordirectlyintotheopticaltransceiverofanydigitalunit.Useanopticalspectrumanalyzertoverifyactivefibers.Placeaprotectivecapoveranyradiatingtransceiveroropticalfiberconnectortoavoidthepotentialofradiationexposure.‐Allowsufficientfiberlengthtopermitroutingwithoutseverebends.‐Forpluggableequipment,makesuretoinstallthesocketoutletneartheequipmentsothatitiseasilyaccessible.‐CertificationFCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRParts15,22,24,27and90UL/CUL:ThisequipmentcomplieswithULandCUL1950‐1Standardforsafetyforinformationtechnologyequipment,includingelectricalbusinessequipmentFDA/CDRH:ThisequipmentusesaClass1LASERaccordingtoFDA/CDRHRules.Thisproductconformstoallapplicablestandardsof21CFRChapter1,SubchaperJ,Part1040
 Confidential & Proprietary                   7/35 ‐Areadyilyaccessibledisconnectdeviceshallbeincorporatedexternaltotheequipment.‐ Thefollowingnotice:"TheManufacturer'sratedoutputpowerofthisequipmentisforsinglecarrieroperation.Forsituationswhenmultiplecarriersignalsarepresent,theratingwouldhavetobereducedby3.5dB,especiallywheretheoutputsignalisre‐radiatedandcancauseinterferencetoadjacentbandusers.Thispowerreductionistobebymeansofinputpowerorgainreductionandnotbyanattenuatorattheoutputofthedevice." ‐Thispowerofthissystemshallbesuppliedthroughwiringinstalledinanormalbuilding.Ifpowereddirectlyfromthemainsdistributionsystem,itshallbeusedadditionalprotection,suchasovervoltageprotectiondevice‐Only50ohmratedantennas,cablesandpassiveequipmentshallbeusedwiththisremote.Anyequipmentattachedtothisdevicenotmeetingthisstandardmaycausedegradationandunwantedsignalsinthebi‐directionalsystem.Allcomponentsconnectedtothisdevicemustoperateinthefrequencyrangeofthisdevice.‐Only50ohmratedantennas,cablesandpassivecomponentsoperatingfrom150‐3GHzshallbeusedwiththisdevice.‐ TheheadendunitmustalwaysbeconnectedtotheBaseStationusingadirectcabledconnection.Thissystemhasnotbeenapprovedforusewithawirelessconnectionviaserverantennatothebasestation.‐Roundterminalslocatedonthesideofa1mm2(16AWG)ormorewiresUsingpermanentlyconnectedtoearth.(green/yellowcolor)‐ThisisonlytobeusedwithBTSdevicessupportinglicensedcellularoperations‐AccesscanonlybegainedbySERVICEPERSONSorbyUSERSwhohavebeeninstructedaboutthereasonsfortherestrictionsappliedtothelocationandaboutanyprecautionsthatshallbetaken;and‐AccessisthroughtheuseofaTOOLorlockandkey,orothermeansofsecurity,andisontrolledbytheauthorityresponsibleforthelocation.‐Notice!BecarefulnottotouchtheHeat‐sinkpartduetohightemperature.
 Confidential & Proprietary                   8/35 ‐Signalboosterwarninglabelmessageshouldinclude‐Useofunauthorizedantennas,cables,and/orcouplingdevicesnotconformingwithERP/EIRPand/orindoor‐onlyrestrictionsisprohibited.CAUTIONDOUBLEPOLE/NEUTRALFUSING
 Confidential & Proprietary                   9/35 Section2  Introduction2.1Purpose2.2HERCULES3.3Dimension
 Confidential & Proprietary                   10/35 2.1 PurposeHERCULESisacoveragesystemforin‐buildingservicesdeliveringvoiceanddatainhighqualityandforseamlessly.Asadistributedantennasystem,itprovidesanaloganddigitalphonesystemsthatareservedinmultiplebandsthroughoneantenna.Thesystemcoversgeneralpublicinstitutionsandprivatefacilities. Shoppingmalls Hotels Campusareas Airports Clinics Subways Multi‐usestadiums,conventioncenters,etc.Thesystemhelpsimprovein‐buildingradioenvironmentsinpoorconditionandmakebetterpoorRSSIandEc/Io.Byprovidingcommunicationservicesateverycornerofbuildings,thesystemenablesuserstomakeacallatanysiteofbuildings.Thesystemusesbothanalog(AMPS)anddigital(TDMA,CDMAandWCDMA)methods.TheHERCULESsystemsupportscommunicationstandardsandpublicinterfaceprotocolsinworldwideuse. Frequencies:700MHz,700MHz_MIMO,850MHz,1900MHz,2100MHz,2100MHz_MIMOetc. Voiceprotocols:AMPS,TDMA,CDMA,GSM,IDEN,etc. Dataprotocols:EDGE,GPRS,WCDMA,CDMA2000,Paging,LTEetc.HERCULESisinmodularstructureperfrequency.Toprovidedesiredfrequencyinabuilding,allyouneedtodoistoinsertacorrespondingfrequencymoduleintoeachunit.Asitdeliversmultiplesignalswithoneopticalcable,thesystem,inone‐bodytype,doesnotrequireadditionalfacilitieswhenevernewfrequencyisadded.Thesystemisfeaturedwiththefollowing: Flexibility&Scalability Supportfiber‐opticportsupto60 Clusteringmultiple‐buildings(campus)asonecoverage Modularstructures
 Confidential & Proprietary                   11/35  Modularfrequencyupgrade Plug‐intypemodule Multi‐Band,MultiOperator Signalswithapluralityofserviceprovidertransmitsimultaneously Supportmulti‐operatorinaband LowOPEX/CAPEX Compactdesign Upgradabledesign Easyinstallationandmaintenance2.2 HERCULESHerculesisoneofseriesofAllianceDASandhas5Wcompositeoutputpowereveryband.RDUthatisintegratedonpackagewithDuplexer,PoweramplifierandRFunitcanbemountedupto6intheenclosure.HerculestransportssignalsthatmultipleoperatorsandmultipletechnologiesaremovedatasametimefromBasestationtoaremotelocationoverthesamefiber.Itisavailableinsingleandmulti‐bandconfigurationsupporting700M,700MMIMO,850M,800I,900I,700P,800P,1700/2100M,1700/2100MHzMIMO,1900M,2.5TDDinparallel.IthasbeenspecificallytestedunderavariousairinterfacessuchasiDEN,GSM,CDMA2000,EV‐DO,WCDMA,LTE,ect.RDUslotisalsopossibletoreplacethedesiredfrequencyBand. 
 Confidential & Proprietary                   12/35 2.3 DimensionFigure3.3–RemoteUnitDimensionITEMSPECIFICATION REMARKSize(Width,Height,Depth)320x1165x260mm IncludingBracketWeight62kg/137lb FullyloadedPowerConsumption510W FullyloadedOperatingTemperature‐25to+55°C /‐13to131°FAmbientTemperatureOperatingHumidity0to90%,non‐condensing 
 Confidential & Proprietary                   13/35 Section3 SystemInstallationThischapterdescribeshowtoinstalleachunitandopticalcables,alongwithpowercablingmethod.Indetail,thechapterdescribeshowtoinstallshelvesorenclosuresofeachunit,PowerCablingmethodandOpticCablingandRFInterface.Theneededaccessoriesandtoolsarelistupinthebelowtable.StepsforinstallationAccessoriesIncluded ToolRemarkRemoteEnclosureInstallationM12Bolt(4EA)XSpanner(19mm)‐PowerConnection_ACAC120Vpowercable(1EA)[2meter,withMIL‐5015typeConnector(MS‐3106A‐18‐10S)atoneend,ACPlugatanotherend]○‐ ‐PowerConnection_DCDC‐48Vpowercable(1EA)[2meter,withMIL‐5015typeConnector(MS‐3106A‐ 18‐10S)atoneend,4.5øsquarelugsatanotherend]○‐ ‐OpticalConnectionOpticalCableAssemblyConnector(1EA)[SOLI‐FIBER‐ASS’Y,byLTW]○  ‐Formoredetails,
 Confidential & Proprietary                   14/35 OPTICSC/APCCable(1EA)X ‐referto4.1.5GroundConnectionM6Screw(1EA)○No.2Screwdriver(+)Formoredetails,referto4.1.4Lug(1EA)○CrimpingToolMax.AWG#6CableXAntennalConnectionRFCable(1or2EA)XSpanner(33mm)2EAisrequiredincaseofMIMO.MRDUInstallation‐ ‐ No.1Screwdriver(+)Formoredetails,referto4.1.6ConnectionwithADDONROUACpowercable(1EA)[1.5meter,withMIL‐5015typeConnector(MS‐3106A‐16‐10S)andCircularConnector (C016_20H003_100_12,byLTW)]○‐ ‐DataInterfacecable(1EA)[1.5meter,withMIL‐5015typeConnector(MS‐3106A‐14S‐5S)atbothends]○‐ ‐RFinterfacecable(2EA)[1.5meter,withNmaleconnectoratbothends]○‐ ‐FANUnit(Option)InnerFanCable○Spanner(10mm)‐ Formoredetails,referto4.1.7FanUnit○‐M6Screw(1EA)XNo.2Screwdriver(+)
 Confidential & Proprietary                   15/35 3.1 RemoteUnitInstallation3.1.1 RemoteUnitEnclosureinstallationRemoteUnitisdesignedtobewater‐anddirt‐proof.Theunithasthestructureofone‐Bodyenclosure.Itsatisfieswater‐proofandquake‐proofstandardsequivalentofNEMA4(IP66).BasicallyRemoteUnitisattachedwithwallmountablebracket.RemoteUnitcanbemountedintoeitherofwalloronapole.Figure4.1–ExteriorofRemoteUnit
 Confidential & Proprietary                   16/35 Figure4.2–DimensionusedtoinstallREMOTEUNITontheWALL
 Confidential & Proprietary                   17/35 RemoteUnitWallMountInstallationRemoteUnit’sinstallationbracketisattachedonEnclosurewhenisdelivered.Itdoesn’tneedtoremovebrackettoinstallenclosure.simplyafterinstalling4ofM12mountingbolts,secure4mountingboltstightlyFirst,install2ofM12mountingboltsroughlyhalfwayontheenclosureandinstallenclosureovertheboltsandsecuretightly.Second,install2ofM12mountingboltsundertheenclosureandsecuretightly.Figure4.3–Proceduresofinstallation
 Confidential & Proprietary                   18/35 RemoteUnitComponentsRemoteUnithasthefollowingcomponents:No.UnitDescriptionRemarkCommonPartEnclosureIncludingWallmountingbracket1EARCPU‐ 1EAR_OPTICWithSC/ACPadaptor(onlyRemoteUnit)1EA,optionalRPSUAC120VorDC‐48V1EAPowerCableMSConnectorwith4hole1EAMRDUMRDU‐850CELMRDU‐1900PCSMRDU‐700LTEMRDU‐2100AWS‐1MRDU‐2500LTE(Reserved)ANT1MRDUMRDU‐700LTE_MIMOMRDU‐2100AWS‐1_MIMOANT2CU1InternalCombinerunitfor700,900,850,1900,2100,and2500(Reserved)ANT1CU2orCU3InternalCombinerunitfor700and2100MIMOInternalCombinerunitfor700P/800Pand900IANT2Basically,thecommonpartofRemoteUnitshouldhaveanenclosureanditisequippedwithRCPUtoinquireandcontrolstateofeachmodule,R_OPTICtomakebothofelectronic‐opticalandoptical‐electronicconversions,RPSUtosupplypowerforRemoteUnit.ItshouldhavePowerCableforexternalrectifierortosupplyrequiredpower.Inaddition,MRDUcanbemountedandremovedtoprovideservicefordesiredband.
 Confidential & Proprietary                   19/35 3.1.2 HowtoexpandADDONROUattheRemoteUnitRemoteUnitcanexpandARUupto1.ThethreeitemisneededforconnectionbetweenRemoteUnitandADDONROU.ADDONROU’scomponentsadditivelyhave3itemexceptforenclosurelikebelowAccessoriesDescriptionQtySpecificationRemark1TXRFCable1N(M)STtoSMA(M)ST_1.5M2RXRFCable1N(M)STtoSMA(M)ST_1.5M3I/OCable1IEC61076‐2‐101(8pin_F)ST_1.5m4PowerCable(ACtypeonly)1MIL‐5015(16‐10_F)STtoCircular(ecomate3+PE_M)ST_1.5mThefollowingpictureshowstheconnectiondiagrambetweenRemoteUnitandADDONROUs
 Confidential & Proprietary                   20/35 ForexpandingADDONROUattheRemoteUnitwithinthepropercablelengthprovided.ThecablesbetweenRemoteUnitandADDONROUhaveeach1.5mlength.Figure4.4–ConnectiondiagrambetweenRemoteUnitandADDONROU(ACtype)Figure4.5–ConnectiondiagrambetweenRemoteUnitandADDONROU(DCtype)
 Confidential & Proprietary                   21/35 3.1.3 RemoteUnitPowerCablingACPowerRemoteUnitsupportsonlyAC120Vofinputpower.Providedoutsidepowercableisonlyonetype.ThepindiscriptionofACportisbelow.YoushouldconnectexactpolarityofAC.PortoutlookMSConnectornumberingNameDescriptionAAC_HACHotBAC_NACNeutralCN.CNotConnectedDF.G FrameGroundCheckiftheconnectionisthesameasoneseeninthetableaboveandmakesuretoturnthepowerON.ProvidedACpowercable’soutlookisbelowDCPowerRemoteUnitsupportsonlyDC48Vofinputpower.Providedoutsidepowercableisonlyonetype.ThepindiscriptionofDCportisbelow.YoushouldconnectexactpolarityofDC.PortoutlookMSConnectornumberingNameDescriptionAN.CNotConnectedBN.CNotConnectedC+V+48VD‐V‐48VCheckiftheconnectionisthesameasoneseeninthetableaboveandmakesuretoturnthepowerON.ProvidedDCpowercable’soutlookisbelow
 Confidential & Proprietary                   22/35 3.1.4 RemoteUnitGroundcablingTheGroundingterminalislocatedatthebottomofRemoteUnitenclosurefixedbyM6screw.Compressionterminalisattachedalreadywhenisdelivered.TherecommendedthicknessofcableisAWG#6coppergroundingwireFigure4.6–LocationofGroundTerminalThespecificationofcompressionterminalislikebelowFigure4.7–InformationofTerminal
 Confidential & Proprietary                   23/35 TherequiredpartnumberisJOCT16‐6supportingAWG6.Thewaytoinstallthegroundingcablecomplywithbelowprocedures  Figure4.8–HowtoinstallGroundTerminalTheproceduresare1. LoosenatwoM6screwsandthentakecompressionterminaloff2. InsertAWG#6GroundingWireintoterminalandthencompressaterminalusingtool3. Assembletheterminalwhichmadeinstep“2”using2xM6screws4. Cutthegroundwiretoproperlengthandconnectittotheearthgroundsource
 Confidential & Proprietary                   24/35 3.1.5 OpticalCablingTheOpticalConnectorislocatedatthebottomofRemoteUnitenclosurefixed.OpticalCablecanbeconnectedbyusingconnectors.Figure4.9–LocationofOpticalConnectorThespecificationofcompressionOpticConnectorislikebelowFigure4.10–InformationofOpticalConnector
 Confidential & Proprietary                   25/35 ThewaytoinstalltheOpticalcablecomplywithbelowproceduresTheproceduresareFigure4.11–HowtoinstallOpticalCabling
 Confidential & Proprietary                   26/35 3.1.6 MountingofMRDURemoteUnithasslotstoenableuptosixMRDUmodulestobemountedinit.YoucanmountaMRDUintodesignatedslotsurely.ItisnotpossibletoprovideserviceswithaMRDUmodulealone;youneedtoconnectMRDUcavityduplexerantennaportwithCU’sdesignatedport.InstallationDiagramforMROUModuleAssembly1)InstalleachMRDUintoitsdesignatedlocationasshowninthegraphic.2)IfMRDUsareinsertedinslot#5or#6,installtheoptionalcombinerunit(CU)accordingtotheseguidelines:Option1:CU_70B21BUsethisunitforcombiningMRDU_700LTEF_B/MRDU_AWS_BOption2:CU_708090UsethisunittocombineMRDU_700PS_800PS/MRDU_900iFigure4.12LocationofMRDU
 Confidential & Proprietary                   27/35 TheRemoteUnitholdsamaximumof6MRDUs.GuidebracketsonthebottomofeachMRDUslotsimplifyinstallationasdescribedbelow.MRDUinstallationrequiresa+No.1tipsizescrewdriver.Figure4.13–HowtomountMRDU
 Confidential & Proprietary                   28/35 Theproceduresare1. LifttheMRDUontotheguidebracketandensuretheMRDUislevellefttoright2. PushtheMRDUintothecorrespondingslotinthedirectionoftheheatsinkwhilelevellingtheMRDUtoguidebracket3. MakesuretheMRDUisfirmlyinsertedintothecorrespondingslot.Tightenthe4cornerscrewstosecuretheunit4. InstallMRDUblankcardsinallunusedslotsintheremote.Firstinserttheblankcardintothecorrespondingslot,thentightenthecaptivescrewtosecureit3.1.7 HowtomountFANUnitFANunitisrequiredtobeinstalledonthebottomofthe5Wremoteasshowninthebelowfigure.InthecasethatMROUtemperatureonGUIexceeds70℃(1580F),thefanunitisrequiredtobeinstalledonthebottomoftheremoteunit.Figure4.14–HowtomountFANUnit
 Confidential & Proprietary                   29/35 Figure4.15–HowtomountFANUnit
 Confidential & Proprietary                   30/35 Theproceduresare1. RemovedummyboltattachedatFANPort2. ConnectinternalFANcabletotheFANPort,andconnectwiththeconnectorlocatedonthetopofPSU.3. Installfanunittothebottomof5Wremotewithaligningheatsinkpintotheguidedgroove.4. SecurethefanunitbytighteningM6screwlocatedontheleftcorner.5. AftersecuringtheFANUnit,connectthecablefromFANunittoFANport.
 Confidential & Proprietary                   31/35 Section4 SystemSpecifications6.1PhysicalSpecifications6.2RFPerformance6.3Certification
 Confidential & Proprietary                   32/35 4.1 PhysicalSpecificationsParameterROUNominalImpedance(inputandoutput)50ohmRFConnectorsDIN Female(7/16)MountingType WallMountingSerialInterfaceconnector(1)RS‐2329‐pinD‐sub,maleFiberconnector(1)SC/APCforODULEDAlarmandStatusIndicatorPowerLEDTXLEDRXLEDLDLEDPDLEDALARMLEDRESETButtonACPower108~132VAC,50/60HzDCPower‐40.8~‐57.6VDCEnvironmentalCondition&IPRatingIP66MaximumPowerConsumption510W atfullloadEnclosureDimensions(mm)320x1165x260mmWeight(FullLoad)62kgOptical DataWavelengthTX/RX 1310/1550nmMaximumOpticalLoss10dBoFiberOpticConnectorSC/APC
 Confidential & Proprietary                   33/35 4.2 RFperformanceMRDU Specifications Per band Downlink Uplink Unit naming  Description  Gain(dB) Bandwidth(MHz) output power(dBm) Frequency range MRDU 850C  Single,  47  25  -5  824 - 849MHz MRDU 850IC  Dual, 47 47 7 25 -5 -5 817 - 824MHz 824 - 849MHz MRDU 1900P  Single,  47  65  -5  1850 - 1915MHz MRDU 700LTE  Single, 47 47 17 10 -5 -5 699 - 716MHz 777 – 787MHz MRDU AWS-1  Single,  47  45  -5  1710 – 1755MHz MRDU 700LTE_MIMO  Single, 47 47 17 10 -5 -5 699 - 716MHz 777 – 787MHz MRDU AWS-1_MIMO  Single,  47  45  -5  1710 – 1755MHz MRDU 900I  Single,  47  6  -5  896 - 902MHz MRDU 700P+800  Dual, 47 47 17 10 -5 -5 788 - 805MHz 806 - 816MHz Unit naming  Description  Gain(dB) Bandwidth(MHz) output power(dBm) Frequency range MRDU 850C  Single,  49  25  +39  869 - 894MHz MRDU 850IC  Dual, 49 49 7 25 +39 +39 862 - 869MHz 869 - 894MHz MRDU 1900P  Single,  53  65  +39  1930 - 1995MHz MRDU 700LTE  Single,  49  28  +39  728 - 756MHz MRDU AWS-1  Single,  53  45  +39  2110 - 2155MHz MRDU 700LTE_MIMO  Single,  53  28  +39  728 - 756MHz MRDU AWS-1_MIMO  Single,  53  45  +39  2110 - 2155MHz MRDU 900I  Single,  49  12  +39  929 - 941MHz MRDU 700P+800  Dual, 49 49 17 10 +39 +39 758 - 775MHz 851 - 861MHz MRDU 2.5TDD  Single  53  189.6  +39  2497.8 - 2687.4MHz
 Confidential & Proprietary                   34/35 MRDU 2.5TDD  Single  47  189.6  -5  2497.8 - 2687.4MHz 4.3 CertificationTitleStandards RemarksEnvironmentalTemperaturerange‐25°Cto+55°C/‐13to131°FAmbientTemperatureHumidityRange0%~90% Non‐condensingSealing(RemoteUnit)IEC60529EN60529IP66ComplaintRSS‐GEN,Sec.7.1.2–(transmitters)UnderIndustryCanadaregulations,thisradiotransmittermayonlyoperateusinganantennaofatypeandmaximum(orlesser)gainapprovedforthetransmitterbyIndustryCanada.Toreducepotentialradiointerferencetootherusers,theantennatypeanditsgainshouldbesochosenthattheequivalentisotropicallyradiatedpower(e.i.r.p.)isnotmorethanthatnecessaryforsuccessfulcommunication.Conformémentàlaréglementationd’IndustrieCanada,leprésentémetteurradiopeutfonctionneravecuneantenned’untypeetd’ungainmaximal(ouinférieur)approuvépourl’émetteurparIndustrieCanada.Danslebutderéduirelesrisquesdebrouillageradioélectriqueàl’intentiondesautresutilisateurs,ilfautchoisirletyped’antenneetsongaindesortequelapuissanceisotroperayonnéequivalente(p.i.r.e.)nedépassepasl’intensiténécessaireàl’établissementd’unecommunicationsatisfaisante.RSS‐GEN,Sec.7.1.2–(detachableantennas)Thisradiotransmitter(identifythedevicebycertificationnumber,ormodelnumberifCategoryII)hasbeenapprovedbyIndustryCanadatooperatewiththeantennatypeslistedbelowwiththemaximumpermissiblegainandrequiredantennaimpedanceforeachantennatypeindicated.Antennatypesnotincludedinthislist,havingagaingreaterthanthemaximumgainindicatedforthattype,arestrictlyprohibitedforusewiththisdevice.Leprésentémetteurradio(identifierledispositifparsonnumérodecertificationousonnumérodemodèles’ilfaitpartiedumatérieldecatégorieI)aétéapprouvéparIndustrieCanadapourfonctionneraveclestypesd’antenneénumérésci‐dessousetayantungainadmissiblemaximaletl’impédancerequisepourchaquetyped’antenne.Lestypesd’antennenoninclusdanscetteliste,oudontlegainestsupérieuraugainmaximalindiqué,sontstrictementinterditspourl’exploitationdel’émetteur.
 Confidential & Proprietary                   35/35 RFRadiationExposureThisequipmentcomplieswithRFradiationexposurelimitssetforthforanuncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwithaminimumdistanceof200cmbetweentheradiatorandyourbody.Thistransmittermustnotbeco‐locatedoroperatinginconjunctionwithanyotherantennaortransmitter.RFexposurewillbeaddressedattimeofinstallationandtheuseofhighergainantennasmayrequirelargerseparationdistances.RSS‐102RFExposureL’antenne(oulesantennes)doitêtreinstalléedefaçonàmainteniràtoutinstantunedistanceminimumdeaumoins200cmentrelasourcederadiation(l’antenne)ettoutepersonnephysique.Cetappareilnedoitpasêtreinstalléouutiliséenconjonctionavecuneautreantenneouémetteur.Warning Statement Antennas must be installed in accordance with FCC 27.50 and SRSP-517. The height of the antenna above average terrain (HAAT) is permitted over 1372m.  For different gain antennas refer to the relevant rules.