SOLiD HM25TDD RDU (Remote Drive Unit) User Manual

SOLiD, Inc. RDU (Remote Drive Unit)

User Manual

Download: SOLiD HM25TDD RDU (Remote Drive Unit) User Manual
Mirror Download [FCC.gov]SOLiD HM25TDD RDU (Remote Drive Unit) User Manual
Document ID2695166
Application ID8O9j3fMpbJJp3OTv/dbr1Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize165.52kB (2068981 bits)
Date Submitted2015-07-28 00:00:00
Date Available2016-01-24 00:00:00
Creation Date2015-07-23 09:34:19
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2015-07-29 08:39:24
Document TitleMicrosoft Word - 8. User's manual_150714_-6,8,35p 추가수정
Document CreatorPScript5.dll Version 5.2.2
Document Author: shkim

HERCULES (Alliance 5W Remote Unit)
User Manual
SOLiD, Inc.
10,9th Floor, SOLiD Space220 Pangyoyeok‐ro, Bundang‐gu, Seongnam‐si, Gyeonggi‐do, Korea 393‐400
Tel : +82‐31‐627‐6290 Fax : +82‐31‐627‐6209
Confidential & Proprietary
1/35
REVISION HISTORY
Version
Issue Date
V 1.0
July. 14, 2015
No. of Pages
Initials
Details of Revision Changes
Original
Technical Support
SOLiD serial numbers must be available to authorize technical support and/or to establish a return
authorization for defective units. The serial numbers are located on the back of the unit, as well as on
the box in which they were delivered. Additional support information may be obtained by accessing the
SOLiD Tehcnology, Inc. website at www.solid.co.kr or send email at
kehan@solid.co.kr
This manual is produced by Global Business Division Business Team 1. Printed in Korea.
Confidential & Proprietary
2/35
Contents
Section1
Safety & Certification Notice ......................................................................... 5
Section2
Introduction ................................................................................................ 9
2.1 Purpose ........................................................................................................... 10
2.2 HERCULES ........................................................................................................ 11
2.3 Dimension ....................................................................................................... 12
Section3
System Installation..................................................................................... 13
3.1 Remote Unit Installation................................................................................... 15
3.1.1 Remote Unit Enclosure installation ................................................................... 15
3.1.2 How to expand ADD ON ROU at the Remote Unit .............................................. 19
3.1.3 Remote Unit Power Cabling .............................................................................. 21
3.1.4 Remote Unit Ground cabling ............................................................................. 22
3.1.5 Optical Cabling................................................................................................. 24
3.1.6 Mounting of MRDU .......................................................................................... 26
3.1.7 How to mount FAN Unit ................................................................................... 28
Section4
System Specifications ................................................................................. 31
4.1 Physical Specifications ...................................................................................... 32
4.2 RF performance ............................................................................................... 33
4.3 Certification ..................................................................................................... 34
Confidential & Proprietary
3/35
Contents of Figure
Figure 3.1 – Remote Unit Block Diagram 오류! 책갈피가 정의되어 있지 않습니다.
Figure 3.2 – Inside of Remote Unit ........ 오류! 책갈피가 정의되어 있지 않습니다.
Figure 3.3 – Remote Unit Dimension ................................................................... 12
Figure 4.1 – Exterior of Remote Unit ................................................................... 15
Figure 4.2 – Dimension used to install REMOTE UNIT on the WALL ........................ 16
Figure 4.3 – Procedures of installation ................................................................ 17
Figure 4.5 – Connection diagram between Remote Unit and ADD ON ROU (DC type)
................................................................................................................ 20
Figure 4.6 – Location of Ground Terminal ............................................................ 22
Figure 4.7 – Information of Terminal ................................................................... 22
Figure 4.8 – How to install Ground Terminal ........................................................ 23
Figure 4.9 – Location of Optical Connector .......................................................... 24
Figure 4.10 – Information of Optical Connector ................................................... 24
Figure 4.11 – How to install Optical Cabling ......................................................... 25
Figure 4.12 – Location of MRDU ......................................................................... 26
Figure 4.13 – How to mount MRDU .................................................................... 27
Figure 4.14 – How to mount FAN Unit ................................................................. 28
Figure 4.15 – How to mount FAN Unit ................................................................. 29
Confidential & Proprietary
4/35
Section1
Safety & Certification Notice
Confidential & Proprietary
5/35
“Only qualified personnel should handle the DAS equipment. Any person involved in
installation or service of the DAS should understand and follow these safety guidelines.”
‐ Obey all general and regional safety regulations relating to work on high voltage installations, as well as
regulations covering correct use of tools and personal protective equipment.
- The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock.
Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed
when servicing repeaters.
‐ To prevent electrical shock, switch the main power supply off prior to working with the DAS System or
Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm.
‐ When working with units outdoors, make sure to securely fasten the door or cover in an open position
to prevent the door from slamming shut in windy conditions.
‐ Use this unit only for the purpose specified by the manufacturer. Do not modify or fit any spare parts
that are not sold or recommended by the manufacturer. This could cause fires, electric shock or other
injuries.
‐ Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid
prolonged exposure to the antennas. SOLiD recommends maintaining a 200cm minimum clearance
from the antenna while the system is operating.
‐ Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures
due to power dissipation.
‐ Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on
the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors.
‐ Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit.
Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating
transceiver or optical fiber connector to avoid the potential of radiation exposure.
‐ Allow sufficient fiber length to permit routing without severe bends.
‐ For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily
accessible.
‐ Certification
 FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24,27 and 90
 UL/CUL: This equipment complies with UL and CUL 1950‐1 Standard for safety for information
technology equipment,including electrical business equipment
 FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product
conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040
Confidential & Proprietary
6/35
‐ A readyily accessible disconnect device shall be incorporated external to the equipment.
‐ The following notice: "The Manufacturer's rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, the rating would have to be reduced
by 3.5 dB, especially where the output signal is re‐radiated and can cause interference to adjacent band
users. This power reduction is to be by means of input power or gain reduction and not by an attenuator
at the output of the device."
‐ This power of this system shall be supplied through wiring installed in a normal building.
If powered directly from the mains distribution system, it shall be used additional protection, such as
overvoltage protection device
‐ Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any
equipment attached to this device not meeting this standard may cause degradation and unwanted
signals in the bi‐directional system. All components connected to this device must operate in the
frequency range of this device.
‐ Only 50 ohm rated antennas, cables and passive components operating from 150 ‐ 3 GHz shall be used
with this device.
‐ The head end unit must always be connected to the Base Station using a direct cabled connection.
This system has not been approved for use with a wireless connection via server antenna to the base
station.
‐ Round terminals located on the side of a 1 mm2 (16 AWG) or more wires Using permanently
connected to earth.(green/yellow color)
‐ This is only to be used with BTS devices supporting licensed cellular operations
‐ Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be taken; and
‐ Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the
authority responsible for the location.
‐ Notice! Be careful not to touch the Heat‐sink part due to high temperature.
Confidential & Proprietary
7/35
‐ Signal booster warning label message should include
‐ Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or
indoor‐only restrictions is prohibited.
CAUTION
DOUBLE POLE/NEUTRAL FUSING
Confidential & Proprietary
8/35
Section2
Introduction
2.1 Purpose
2.2 HERCULES
3.3 Dimension
Confidential & Proprietary
9/35
2.1
Purpose
HERCULES is a coverage system for in‐building services delivering voice and data in high quality and for
seamlessly.
As a distributed antenna system, it provides analog and digital phone systems that are served in multiple
bands through one antenna.
The system covers general public institutions and private facilities.

Shopping malls

Hotels

Campus areas

Airports

Clinics

Subways

Multi‐use stadiums, convention centers, etc.
The system helps improve in‐building radio environments in poor condition and make better poor RSSI
and Ec/Io. By providing communication services at every corner of buildings, the system enables users to
make a call at any site of buildings.
The system uses both analog (AMPS) and digital (TDMA, CDMA and WCDMA) methods.
The HERCULES system supports communication standards and public interface protocols in worldwide
use.

Frequencies: 700MHz , 700MHz_MIMO , 850MHz , 1900MHz , 2100MHz , 2100MHz_MIMO
etc.

Voice protocols: AMPS,TDMA, CDMA,GSM,IDEN, etc.

Data protocols: EDGE,GPRS,WCDMA,CDMA2000,Paging, LTE etc.
HERCULES is in modular structure per frequency. To provide desired frequency in a building, all you
need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals
with one optical cable, the system, in one‐body type, does not require additional facilities whenever
new frequency is added.
The system is featured with the following:


Flexibility & Scalability

Support fiber‐optic ports up to 60

Clustering multiple‐buildings (campus) as one coverage
Modular structures
Confidential & Proprietary
10/35


2.2

Modular frequency upgrade

Plug‐in type module
Multi‐Band, Multi Operator

Signals with a plurality of service provider transmit simultaneously

Support multi‐operator in a band
Low OPEX / CAPEX

Compact design

Upgradable design

Easy installation and maintenance
HERCULES
Hercules is one of series of Alliance DAS and has 5W composite output power every band.
RDU that is integrated on package with Duplexer, Power amplifier and RF unit can be mounted up to 6 in
the enclosure.
Hercules transports signals that multiple operators and multiple technologies are moved at a same time
from Base station to a remote location over the same fiber.
It is available in single and multi‐band configuration supporting 700M, 700M MIMO , 850M , 800I , 900I ,
700P , 800P , 1700/2100M, 1700/2100MHz MIMO , 1900M , 2.5TDD in parallel.
It has been specifically tested under a various air interfaces such as iDEN, GSM, CDMA2000, EV‐DO,
WCDMA, LTE , ect.
RDU slot is also possible to replace the desired frequency Band.
Confidential & Proprietary
11/35
2.3
Dimension
Figure 3.3 – Remote Unit Dimension
ITEM
Size(Width, Height, Depth)
Weight
Power Consumption
Operating Temperature
Operating Humidity
Confidential & Proprietary
SPECIFICATION
320 x 1165 x 260mm
62kg / 137lb
510W
‐25 to +55°C / ‐13 to 131°F
0 to 90%, non‐condensing
12/35
REMARK
Including Bracket
Fully loaded
Fully loaded
Ambient Temperature
Section3
System
Installation
This chapter describes how to install each unit and optical cables, along with power cabling method. In
detail, the chapter describes how to install shelves or enclosures of each unit, Power Cabling method
and Optic Cabling and RF Interface.
The needed accessories and tools are list up in the below table.
Steps for
Accessories
installation
Included
Tool
Remark
Spanner(19mm)
‐
○
‐
‐
○
‐
‐
○
‐
Remote
Enclosure
M12 Bolt (4EA)
Installation
AC 120V power cable (1EA)
Power
[2 meter, with MIL‐5015 type Connector (MS‐
Connection_AC
3106A‐ 18‐10S) at one end, AC Plug at another
end]
DC ‐48V power cable (1EA)
Power
[2 meter, with MIL‐5015 type Connector (MS‐
Connection_DC
3106A‐ 18‐10S) at one end, 4.5 ø square lugs
at another end]
Optical
Optical Cable Assembly Connector (1EA)
Connection
[SOLI‐FIBER‐ASS’Y, by LTW]
Confidential & Proprietary
13/35
For more
details,
Ground
Connection
OPTIC SC/APC Cable (1EA)
‐
M6 Screw (1EA)
○
No.2 Screw driver (+)
Lug (1EA)
○
Max. AWG #6 Cable
refer
4.1.5
For more
details,
Crimping Tool
refer
Connection
RF Cable (1 or 2EA)
to
4.1.4
Antennal
to
Spanner (33mm)
EA
is
required
in case of
MIMO.
For more
MRDU
Installation
‐
‐
No.1 Screw driver (+)
details,
refer
to
4.1.6
AC power cable (1 EA)
[1.5 meter, with MIL‐5015 type Connector
○
‐
‐
○
‐
‐
○
‐
‐
Inner Fan Cable
○
Spanner (10mm)‐
Fan Unit
○
‐
M6 Screw (1EA)
No.2 Screw driver (+)
(MS‐3106A‐16‐10S) and Circular Connector
Connection
with ADD ON
ROU
(C016_20H003_100_12, by LTW)]
Data Interface cable (1 EA)
[1.5 meter, with MIL‐5015 type Connector
(MS‐3106A‐14S‐5S) at both ends]
RF interface cable (2EA)
[1.5 meter, with N male connector at both
ends]
FAN Unit
(Option)
Confidential & Proprietary
14/35
For more
details,
refer
4.1.7
to
3.1
Remote Unit Installation
3.1.1 Remote Unit Enclosure installation
Remote Unit is designed to be water‐ and dirt‐proof. The unit has the structure of one‐Body enclosure.
It satisfies water‐proof and quake‐proof standards equivalent of NEMA4(IP66). Basically Remote Unit is
attached with wall mountable bracket. Remote Unit can be mounted into either of wall or on a pole.
Figure 4.1 – Exterior of Remote Unit
Confidential & Proprietary
15/35
Figure 4.2 – Dimension used to install REMOTE UNIT on the WALL
Confidential & Proprietary
16/35
Remote Unit Wall Mount Installation
Remote Unit’s installation bracket is attached on Enclosure when is delivered. It doesn’t need to remove
bracket to install enclosure. simply after installing 4 of M12 mounting bolts, secure 4 mounting bolts
tightly
First, install 2 of M12 mounting bolts roughly half way on the enclosure and install enclosure over the
bolts and secure tightly.
Second, install 2 of M12 mounting bolts under the enclosure and secure tightly.
Figure 4.3 – Procedures of installation
Confidential & Proprietary
17/35
Remote Unit Components
Remote Unit has the following components:
No.
Unit
Description
Remark
Enclosure
Including Wall mounting bracket
1EA
RCPU
‐
1EA
R_OPTIC
With SC/ACP adaptor(only Remote Unit)
1EA,optional
RPSU
AC 120V or DC‐48V
1EA
Power Cable
MS Connector with 4 hole
1EA
MRDU‐850CEL
MRDU‐1900PCS
Common Part
MRDU
MRDU‐700LTE
ANT1
MRDU‐2100AWS‐1
MRDU‐2500LTE(Reserved)
MRDU
CU1
CU2 or CU3
MRDU‐700LTE_MIMO
MRDU‐2100AWS‐1_MIMO
Internal Combiner unit for 700, 900,850, 1900, 2100,
and 2500(Reserved)
Internal Combiner unit for 700 and 2100 MIMO
Internal Combiner unit for 700P/800P and 900I
ANT2
ANT1
ANT2
Basically, the common part of Remote Unit should have an enclosure and it is equipped with RCPU to
inquire and control state of each module, R_OPTIC to make both of electronic‐optical and optical‐
electronic conversions, RPSU to supply power for Remote Unit. It should have Power Cable for external
rectifier or to supply required power.
In addition, MRDU can be mounted and removed to provide service for desired band.
Confidential & Proprietary
18/35
3.1.2 How to expand ADD ON ROU at the Remote Unit
Remote Unit can expand ARU up to 1. The three item is needed for connection between Remote Unit
and ADD ON ROU. ADD ON ROU’s components additively have 3 item except for enclosure like below
Accessories
Description
Qty
TX RF Cable
RX RF Cable
Specification
Remark
N(M) ST to SMA(M)
ST_1.5M
N(M) ST to SMA(M)
ST_1.5M
IEC 61076‐2‐
I/O Cable
101(8pin_F)
ST_1.5m
MIL‐5015(16‐10_F)
Power Cable
(AC type only)
ST to Circular(eco
mate 3+PE_M)
ST_1.5m
The following picture shows the connection diagram between Remote Unit and ADD ON ROUs
Confidential & Proprietary
19/35
For expanding ADD ON ROU at the Remote Unit within the proper cable length provided. The cables
between Remote Unit and ADD ON ROU have each 1.5m length.
Figure 4.4 – Connection diagram between Remote Unit and ADD ON ROU (AC type)
Figure 4.5 – Connection diagram between Remote Unit and ADD ON ROU (DC type)
Confidential & Proprietary
20/35
3.1.3 Remote Unit Power Cabling
AC Power
Remote Unit supports only AC120V of input power. Provided outside power cable is only one type.
The pin discription of AC port is below. You should connect exact polarity of AC.
Port outlook
MS Connector numbering
Name
Description
AC_H
AC Hot
AC_N
AC Neutral
N.C
Not Connected
F.G
Frame Ground
Check if the connection is the same as one seen in the table above and make sure to turn the power ON.
Provided AC power cable’s outlook is below
DC Power
Remote Unit supports only DC48V of input power. Provided outside power cable is only one type.
The pin discription of DC port is below. You should connect exact polarity of DC.
Port outlook
MS Connector numbering
Name
Description
N.C
Not Connected
N.C
Not Connected
+V
+48V
‐V
‐48V
Check if the connection is the same as one seen in the table above and make sure to turn the power ON.
Provided DC power cable’s outlook is below
Confidential & Proprietary
21/35
3.1.4 Remote Unit Ground cabling
The Grounding terminal is located at the bottom of Remote Unit enclosure fixed by M6 screw.
Compression terminal is attached already when is delivered. The recommended thickness of cable is
AWG#6 copper grounding wire
Figure 4.6 – Location of Ground Terminal
The specification of compression terminal is like below
Figure 4.7 – Information of Terminal
Confidential & Proprietary
22/35
The required part number is JOCT 16‐6 supporting AWG 6. The way to install the grounding cable
comply with below procedures
Figure 4.8 – How to install Ground Terminal
The procedures are
1.
Loosen a two M6 screws and then take compression terminal off
2.
Insert AWG#6 Grounding Wire into terminal and then compress a terminal using tool
3.
Assemble the terminal which made in step “2” using 2xM6 screws
4.
Cut the ground wire to proper length and connect it to the earth ground source
Confidential & Proprietary
23/35
3.1.5 Optical Cabling
The Optical Connector is located at the bottom of Remote Unit enclosure fixed. Optical Cable can be
connected by using connectors.
Figure 4.9 – Location of Optical Connector
The specification of compression Optic Connector is like below
Figure 4.10 – Information of Optical Connector
Confidential & Proprietary
24/35
The way to install the Optical cable comply with below procedures
The procedures are
Figure 4.11 – How to install Optical Cabling
Confidential & Proprietary
25/35
3.1.6 Mounting of MRDU
Remote Unit has slots to enable up to six MRDU modules to be mounted in it.
You can mount a MRDU into designated slot surely. It is not possible to provide services with a
MRDU module alone; you need to connect MRDU cavity duplexer antenna port with CU’s
designated port.
Installation Diagram for MROU Module Assembly
1) Install each MRDU into its designated location as shown in the graphic.
2) If MRDUs are inserted in slot #5 or #6, install the optional combiner unit (CU) according to
these guidelines:
Option 1: CU_70B21B
Use this unit for combining MRDU_700LTEF_B / MRDU_AWS_B
Option 2 : CU_708090
Use this unit to combine MRDU_700PS_800PS / MRDU_900i
Figure 4.12 Location of MRDU
Confidential & Proprietary
26/35
The Remote Unit holds a maximum of 6 MRDUs. Guide brackets on the bottom of each MRDU slot
simplify installation as described below. MRDU installation requires a +No.1 tip size screwdriver.
Figure 4.13 – How to mount MRDU
Confidential & Proprietary
27/35
The procedures are
1.
Lift the MRDU onto the guide bracket and ensure the MRDU is level left to right
2.
Push the MRDU into the corresponding slot in the direction of the heat sink while levelling the
MRDU to guide bracket
3.
Make sure the MRDU is firmly inserted into the corresponding slot. Tighten the 4 corner
screws to secure the unit
4.
Install MRDU blank cards in all unused slots in the remote. First insert the blank card into the
corresponding slot, then tighten the captive screw to secure it
3.1.7 How to mount FAN Unit
FAN unit is required to be installed on the bottom of the 5W remote as shown in the below figure.
In the case that MROU temperature on GUI exceeds 70℃ (1580F), the fan unit is required to be
installed on the bottom of the remote unit.
Figure 4.14 – How to mount FAN Unit
Confidential & Proprietary
28/35
Figure 4.15 – How to mount FAN Unit
Confidential & Proprietary
29/35
The procedures are
1.
Remove dummy bolt attached at FAN Port
2.
Connect internal FAN cable to the FAN Port, and connect with the connector located on the
top of PSU.
3.
Install fan unit to the bottom of 5W remote with aligning heatsink pin to the guided groove.
4.
Secure the fan unit by tightening M6 screw located on the left corner.
5.
After securing the FAN Unit, connect the cable from FAN unit to FAN port.
Confidential & Proprietary
30/35
Section4
System Specifications
6.1 Physical Specifications
6.2 RF Performance
6.3 Certification
Confidential & Proprietary
31/35
4.1
Physical Specifications
Parameter
Nominal Impedance(input and output)
RF Connectors
Mounting Type
AC Power
DC Power
Environmental Condition & IP Rating
Maximum Power Consumption
Enclosure Dimensions (mm)
ROU
50 ohm
DIN Female (7/16)
Wall Mounting
(1) RS‐232 9‐pin
D‐sub, male
(1) SC/APC for ODU
Power LED
TX LED
RX LED
LD LED
PD LED
ALARM LED
RESET Button
108~132V AC, 50/60Hz
‐40.8 ~ ‐57.6V DC
IP66
510W at full load
320 x 1165 x 260mm
Weight (Full Load)
62kg
Serial Interface connector
Fiber connector
LED Alarm and Status Indicator
Optical Data
Wavelength TX/RX
Maximum Optical Loss
Fiber Optic Connector
Confidential & Proprietary
1310/1550nm
10dBo
SC/APC
32/35
4.2
RF performance
MRDU Specifications Per band
Unit naming
Description
Gain(dB)
Bandwidth(MHz)
output power(dBm)
Frequency range
MRDU 850C
Single,
49
25
+39
869 - 894MHz
49
+39
862 - 869MHz
MRDU 850IC
Dual,
49
25
+39
869 - 894MHz
MRDU 1900P
Single,
53
65
+39
1930 - 1995MHz
MRDU 700LTE
Single,
49
28
+39
728 - 756MHz
MRDU AWS-1
Single,
53
45
+39
2110 - 2155MHz
MRDU 700LTE_MIMO
Single,
53
28
+39
728 - 756MHz
MRDU AWS-1_MIMO
Single,
53
45
+39
2110 - 2155MHz
MRDU 900I
Single,
49
12
+39
929 - 941MHz
49
17
+39
758 - 775MHz
MRDU 700P+800
Dual,
49
10
+39
851 - 861MHz
Single
53
189.6
+39
2497.8 - 2687.4MHz
Description
Gain(dB)
MRDU 850C
Single,
47
25
-5
824 - 849MHz
47
-5
817 - 824MHz
MRDU 850IC
Dual,
47
25
-5
824 - 849MHz
47
65
-5
1850 - 1915MHz
47
17
-5
699 - 716MHz
47
10
-5
777 – 787MHz
47
45
-5
1710 – 1755MHz
47
17
-5
699 - 716MHz
47
10
-5
777 – 787MHz
MRDU 2.5TDD
Downlink
Uplink
Unit naming
MRDU 1900P
Single,
MRDU 700LTE
Single,
MRDU AWS-1
Single,
MRDU 700LTE_MIMO
Single,
Bandwidth(MHz)
output power(dBm)
Frequency range
MRDU AWS-1_MIMO
Single,
47
45
-5
1710 – 1755MHz
MRDU 900I
Single,
47
-5
896 - 902MHz
47
17
-5
788 - 805MHz
MRDU 700P+800
Dual,
47
10
-5
806 - 816MHz
Confidential & Proprietary
33/35
MRDU 2.5TDD
4.3
Single
47
189.6
-5
2497.8 - 2687.4MHz
Certification
Title
Environmental
Temperature range
Humidity Range
Sealing (Remote
Standards
Remarks
‐25°C to +55°C/ ‐13 to 131°F
0% ~ 90%
Ambient Temperature
Non‐condensing
IEC 60 529 EN 60 529
IP66 Complaint
Unit)
RSS‐GEN, Sec. 7.1.2 – (transmitters)
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec
une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie
Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres
utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée
quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication
satisfaisante.
RSS‐GEN, Sec. 7.1.2 – (detachable antennas)
This radio transmitter (identify the device by certification number, or model number if Category II)has
been approved by Industry Canada to operate with the antenna types listed below with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de
modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner
avec les types d’antenne énumérés ci‐dessous et ayant un gain admissible maximal et l’impédance
requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est
supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Confidential & Proprietary
34/35
RF Radiation Exposure
This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 200 cm between the
radiator and your body. This transmitter must not be co‐located or operating in conjunction with any
other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher
gain antennas may require larger separation distances.
RSS‐102 RF Exposure
L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance
minimum de au moins 200 cm entre la source de radiation (l’antenne) et toute personne physique. Cet
appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur.
Warning Statement
Antennas must be installed in accordance with FCC 27.50 and SRSP-517. The height of the
antenna above average terrain (HAAT) is permitted over 1372m. For different gain antennas
refer to the relevant rules.
Confidential & Proprietary
35/35

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : shkim
Create Date                     : 2015:07:23 09:34:19+09:00
Modify Date                     : 2015:07:29 08:39:24+09:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:07:29 08:39:24+09:00
Format                          : application/pdf
Title                           : Microsoft Word - 8. User's manual_150714_-6,8,35p 추가수정
Creator                         : shkim
Document ID                     : uuid:9ab19ef5-179a-4660-aa00-8202f57bb941
Instance ID                     : uuid:3173f11b-f1e6-4b23-abd2-4af1d14cf309
Page Count                      : 35
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W6UHM25TDD

Navigation menu