SOYAL TECHNOLOGY AR-888 Access Controller User Manual
SOYAL TECHNOLOGY CO., LTD. Access Controller User Manual
User_Manual
SOYAL ® AR-888 V150708 ACCESS CONTROL SYSTEM Contents AR-888 Series 1 Product (US / EU) 2 User Guide 3 Terminal Cables CN1 CN2 WG-Input 4 Tools CN4 RS-485 CN5 Flat Head Hex Socket Screw: M3x8 CN9 Duress 5 EVA foam gasket (US/ EU) Iron bar*2 (Inserted into Product) Bottom Cover FCC Statement (part15.21,15.105) Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Installation Take off two Iron bars from the of bottom body A and and mounting plate B. Pull the cables from the square holes of the eva foam gasket and mounting plate. A. B. C. (Excluded) Use a screwdriver to screw the eva foam gasket C and mounting plate B onto the wall with Flat Head Cap Philips Tapping Screws (Excluded, the Installer should prepare before installation. The screws shall not be screwed too tight, or it could lead to the deformation of the mounting plate. In-wall Depth 32mm Connect the cables to the backside of body A and attach A to B . To fix A on B by inserting two Iron bars from the bottom of A + B. Attach the Back Cover D to A. Use the Allen key and screws to assemble the Back Cover onto the body. (Excluded) Hands-off and clear any objects around the 888 (H/K). Turn on the power and LED will light-up and beep will sound. Wait the Touch IC start for 10 sec. to operate. D. Cable selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring. Use CAT5 for TCP/IP connection. (Excluded) Indicators: 1*Bi-Color AR-888 (H/K/U) 3*One Color LED AR-PBI-888 1*Bi-Color Green-Red Green (Optional) White (Stand-By) Red (Optional) Green-Red (Exchangeable) US Mounting Hole: 73x48x40mm(HxWxD) / Screw hole pitch : 84mm Suitable for 70X118 1-module flushmounting box.( Australian, Italy, USA(501E) Standard) EU Mounting Hole: 57x53x40mm(HxWxD) / Screw hole pitch: 60mm Suitable for 86X86 flush-mounting box. (UK, Continental Europe, Germany Standard) Steps of Ferrite Core Installation Power DC Input cable 1. Open up the Ferrite Core box 2. To wind the DC in Cable around the Ferrite Core two times 3. The close up the Ferrite Core www.soyal.com Flush-Mounted Series Basic Commands Wiring Diagrams Alarm Output 3-Lift Control Wiring Enter program mode 123456 AR-401RO16B Node ID 001 Lift Controller Change program code AR-321L485 Host BA+ BConverter A+ RX Input 6-digit PWD twice SET 09 654321654321 Add Card User (Please list down each User Address and its Card ID) User Range: 00000~03000 Delete Card User 10 00001 00005 Ex.: 00001 start user address at 00001 and scanned 50 pcs of card one by one; next time, input 16 15 14 13 12 11 10 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25 M6 Mode Ex.: 00001 start user address at 00001 00005 end user address at 00001 Totally 5 user cards will be disabled. PIN=0000 (Disable) M4/M8 Mode (4/8 beeps while engtering progrm mode) (Delete all cards and parameters) 29 20 Alarm Output 1- Alarm Wiring UUUUU FFFFFFFF 064 128 (Enable) (Disable) Enable Door Open Too Long Alarm Enable Arming while exit program mode N.C. N.O. COM CTL 12V External Relay Stop Alarm by Push Button 24 24 064 000 (Enable) (Disable) Exit Button Wiring POWER 12VDC Push Button AR-PBI888 AR-888 (H) CN9 Hall-Effect Sensor (Active Low) CN1 Door Sensor Wiring N.C. LA+ LB- or Electric Bolt CN2 GND DC12V Alarm PB Door SEN. COM N.C. N.O. Door Lock Wiring GND Duress Arming Stand-Alone /Networking Controller CN4 Magnetic Lock WG1 WG0 Buzzer GLED RLED CN5 Electric Strike M4/M8 Mode 13 00001 4321 WG Reader Wiring M6 Mode 17 4321 CN1 WG Open Open Short Short Short RST/Bits Open Short Open Short Open Hall-Effect Sensor (Active Low) GND DC12V Card Present AR-888 (K/U) 13.56MHz WG/ABA Format (Change by wires connection) Format SET 1 SET 2 WG 26 Open Open WG 34 Open To GND ABA-10 To GND Open ABA-5-5 To GND To GND GND GLED Input (Active High) RLED Input (Active High) Note HEX HEX BCD10 BCD SET1 (Format) SET2 (Format) 13.56MHz LA+ (FW Only) LB- (FW Only) CN2 WG-Buzzer WG-GLED RLED Reserved WG0 WG1 CN4 13.56MHz 02 007 Networking Connection Wiring Set up Node ID Ex. Node 32 connected to PC 00 032 00 009 032 032 Ex. Node 9 conected to 716E 032=Node ID of Access Controller 032=Virtual 716E Node ID 032=Door number (All Range:001~254) 009=Node ID of Access Controller Range: 001~254) Notice: Each CH up to At every 32 units or at every300M connection to add a RS485 Booster. Suggest to connect up to 32 units for each CH of AR-727CM 8 Nodes BCH2 A+ BCH1 A+ BHost A+ WG RST Format WG 26 WG 34 RS-232 ABA-8 ABA-10 AR-888 (K/U) CN9 WG Reader AR-888 (K/U) 125kHz WG/ABA/RS232 Format (Change by shorted on PCB) Exit program mode 21 Alarm Door Contact PIN=0000 (Disable) 18 015 FF S=Set=0~3 FFFFFFFF=0 (Disable) / 1 (Enable) 28 28 Reset to Factory Default Value Add Card+PIN User Set up Door Close Time UUUUU GND GLED Input (Active High) RLED Input (Active High) 15 1234 TTT: 001~600=1~600 sec. 601~609=0.1~0.9sec. 000=On/ Off (Latch) (Disable) Occupied Alarm Output to support M6 Mode (6 beeps) Set up Door Relay Time 27 CN1 12 00001 1234 (Enable) UUUUU=User Address=00000~03000 FF=Floor number=1~32 N.O. COM N.C. GND DC12V Delete All User Cards 29 29 Add PIN User 002 000 Assign Users (Single Floor) N.C. N.O. COM CTL 12V 19*00051*00001# Attach/Present Card One by One 24 24 Assign Floor User (Multi-Floor) Ex. Assign user address 1 to access to 1, 3, 5, 7 floor 21*00001*0*01010101# Lock M4/M8 Mode M6 Mode (Must set up 17*0000#) 22 1 External Relay 10 00001 9 00005 19 00001 00001 Floor/ Stop Enable Life Control Alarm Output 2- WG Dual Door Control Wiring User Range: 00000~03000 M4/M8 Mode TTT: 001~600=1~600 sec. V150708 CN5 125kHz Multi-Door Controller Node ID 001 Converter AR-321CM AR-727CM AR-888(H) Node ID 254 AR-888(H) Node ID 032 AR-888(H) Node ID 002 www.soyal.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:d123b04d-60de-49d6-9300-b2627c6bf8b4 Original Document ID : adobe:docid:indd:6bb7d298-5bc0-11e2-9c94-f3300fefe47f Document ID : xmp.id:58624B00DCB9E511B488B39287F2F888 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:08F2A9101CB5E5119A6AE4CF1C176F3A Derived From Document ID : xmp.did:9FD8A4EC1BB5E5119A6AE4CF1C176F3A Derived From Original Document ID: adobe:docid:indd:6bb7d298-5bc0-11e2-9c94-f3300fefe47f Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2016:01:13 17:57:05+08:00 Create Date : 2016:01:13 17:57:05+08:00 Modify Date : 2016:01:13 17:57:06+08:00 Metadata Date : 2016:01:13 17:57:06+08:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools