         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100       Wall Mount Booster LG Installation Instructions   FCC ID: NTAWMLG IC: 4732A-WMLG    14-Nov-11
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100    CAUTIONTheUserandtheInstallershouldbeawarethatchangesandmodificationstotheequipmentnotexpresslyapprovedbyMasterMetercouldvoidwarrantyandtheuser'sauthoritytooperatetheequipment.Professionallytrainedpersonnelshouldinstalltheequipment.Theantennausedforthistransmittermustbeinstalledtonormallyprovideminimumseparationdistanceofatleast20cmfromallpersonsandmustnotbeco‐locatedoroperatinginconjunctionwithanyotherantennaortransmitterATTENTIONThedigitalportionofthetransceiverhasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:1.)Reorientorrelocatethereceivingantenna.2.)Increasetheseparationbetweentheequipmentandreceiver.3.)Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.4.)Consultthedealeroranexperiencedradio/TVtechnicianforhelp.ThisdevicecomplieswithPart15ofFCCRulesandwithIndustryCanadalicence‐exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :  (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100     INTRODUCTION The2WM‐LGendunitforwatermetersprovidestwo‐waycommunicationcapabilitiesovertheLandis&GyrGridstreamTMRFNetwork.The2WM‐LGisbatteryoperatedunitintheunlicensed902‐928MHzband.TheunitcomplieswithPart15oftheFCCrulesFollowingarethemainfeaturesofthe2WM‐LGunit: Periodicallytransmissionofthewatermeterreadings(1‐4timesperday) Onrequestreadsforlast‐timemeterreads Alarmreport&datalogging Remote,over‐the‐airfirmwareupgrades Remoteunitconfigurations ConfirmationofnetworkconnectivityThe2WM‐LGmaybeconnectedtothefollowingmeters(butnotlimitedto): SegentiaTM InvensysTM Hersey5/8"TM ABBTM NeptuneARB_VTM NeptuneARB‐2TM SensusTM SchlumbergerARB_VTM 3GLCD(Aradtechnologies)TM
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100     1‐PlaceSettingo The2WM‐LGunitcanbewallmountedinanexternalopensiteorwithinbuildingsNote:The2WM‐LGdatatransmissionmaybeadverselyaffectedifitisinstalledclosetoRForEMnoisegenerators,forexample:airconditionerunits,electricgenerator,radiotransmitter,carparkingandothers.Ifyouencountersuchproblems,pleaseconsultMasterMeterServicerepresentativefortechnicalassistance.
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100      2–KitContents Quantity Name1112212WM‐LGunitSealCoverWallMountClipTappingscrewPlasticmasonryinsertIDlabelstickerformeteridentity
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100      2WM‐LGunit–Profile#1
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100    3–InstallationProcedureThe2WM‐LGisintendedforwallinstallationinopensitesandbuildings.1.Markthelocationsofthetwoscrewsonthewall,accordingtotheholesinthewallmountclipoftheunit.2.Drill2holesandinsertthePlasticmasonryinserts.3.Connectthewallmountclipwiththetwoscrewsupplied.MarkLocationInsertscrews
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100    4.Attachedthe2WMB‐LGunittotheclip.5.Sealthecableholewiththesuppliedsealcover.2WM‐LGonthewallSealCover
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100    6.Connectthewireoftheunitaccordingtotheconnectionguideonthewaterunit,payattentiontoconnectitright.
         101 REGENCY PARKWAYMANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100    4–UnitActivation1.FacetheMagnetonthe2WMB‐LGcase.2.Removethemagnetafter5seconds.