ST Engineering Telematics Wireless WMLG Water meter User Manual manual
Telematics Wireless Ltd. Water meter manual
manual
101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 Wall Mount Booster LG Installation Instructions FCC ID: NTAWMLG IC: 4732A-WMLG 14-Nov-11 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 CAUTION The User and the Installer should be aware that changes and modifications to the equipment not expressly approved by Master Meter could void warranty and the user's authority to operate the equipment. Professionally trained personnel should install the equipment. The antenna used for this transmitter must be installed to normally provide minimum separation distance of at least 20 cm from all persons and must not be co‐located or operating in conjunction with any other antenna or transmitter ATTENTION The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1.) Reorient or relocate the receiving antenna. 2.) Increase the separation between the equipment and receiver. 3.) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4.) Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of FCC Rules and with Industry Canada licence‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 INTRODUCTION The 2WM‐LG end unit for water meters provides two‐way communication capabilities over the Landis & Gyr Gridstream TM RF Network. The 2WM‐LG is battery operated unit in the unlicensed 902‐928MHz band. The unit complies with Part 15 of the FCC rules Following are the main features of the 2WM‐LG unit: Periodically transmission of the water meter readings (1‐4 times per day) On request reads for last‐time meter reads Alarm report & data logging Remote, over‐the‐air firmware upgrades Remote unit configurations Confirmation of network connectivity The 2WM‐LG may be connected to the following meters (but not limited to): Segentia TM Invensys TM Hersey 5/8" TM ABB TM Neptune ARB_V TM Neptune ARB ‐2 TM Sensus TM Schlumberger ARB_V TM 3G LCD (Arad technologies) TM 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 1 ‐ Place Setting o The 2WM‐LG unit can be wall mounted in an external open site or within buildings Note: The 2WM‐LG data transmission may be adversely affected if it is installed close to RF or EM noise generators, for example: air conditioner units, electric generator, radio transmitter, car parking and others. If you encounter such problems, please consult Master Meter Service representative for technical assistance. 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 2 – Kit Contents Quantity 2WM‐LG unit Name Seal Cover Wall Mount Clip Tapping screw Plastic masonry insert ID label sticker for meter identity 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 2WM‐LG unit – Profile #1 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 3 – Installation Procedure The 2WM‐LG is intended for wall installation in open sites and buildings. 1. Mark the locations of the two screws on the wall, according to the holes in the wall mount clip of the unit. Mark Location 2. Drill 2 holes and insert the Plastic masonry inserts. 3. Connect the wall mount clip with the two screw supplied. Insert screws 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 4. Attached the 2WMB‐LG unit to the clip. 2WM‐ LG on the wall 5. Seal the cable hole with the supplied seal cover. Seal Cover 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 6. Connect the wire of the unit according to the connection guide on the water unit, pay attention to connect it right. 101 REGENCY PARKWAY MANSFIELD, TX 76063 817-842-8000 FAX 817-842-8100 4 – Unit Activation 1. Face the Magnet on the 2WMB‐LG case. 2. Remove the magnet after 5 seconds.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : marina Create Date : 2012:01:05 14:31:41+02:00 Modify Date : 2012:01:05 14:32:13+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2012:01:05 14:32:13+02:00 Format : application/pdf Title : Microsoft Word - Installation_instructions_22412.doc Creator : marina Document ID : uuid:b95a5b52-8f9f-4c97-9235-6d18c0225534 Instance ID : uuid:2d9ad80e-e3a0-4fe8-a007-9ddd8674bd13 Page Count : 10EXIF Metadata provided by EXIF.tools