SZ PGST PG-103 Alarm Host User Manual

SZ PGST CO., LTD Alarm Host

User manual

GSM & WiFi Alarm SystemUser ManualWIFI+GSM/3G+GPRSScan QR code heredownload and install APPApp StoreAndroid
ContentOverall stateExplanationFeatures Identification for daily operationTop viewBottom viewSide viewKeys of side faceMain interfaceDescription for main interfaceMenu structureStartSystem initializationMenu operationPhone number setupAdd/Delete remote controlAdd/Delete wireless detector(included doorbell alarm)Add/Delete RFID cardSynchronization with external wireless siren RecordTimerInstallAPP configuration with alarm hostUnbind mobile phone APP with alarm hostAdd remote control via APPAdd detector via APPDelete remote control via APPDelete detector via APP1~21123~73344456~788888991010111112~181212131314~151617Alarm host appearance and accessoriesInitial usageMobile phone APPCONTENT
Inquire/set parameter: Set function switch, Set alarm phone,Set delay alarm Synchronize external wireless siren via APP 1718Parameter setupAlarm host name setupParameter inquiryInquire system settingInquire system setting2Alarm phone setup inquiryDelay setup inquirySwitch setup inquiryRemote control/detector/RFID card inquirySMS alarmVoice alarm and remote monitoringAutomatic dialing preset phone number when the alarm host alarmsPreset phone number to call alarm host       Alarm receiving procedure via APP       Receiving alarm by Intranet monitoring center19~211919202020212121212226~2726262626262723~25Out ArmStay ArmDisarmSOSSMS notification feedback23242425252829Remote SMSPhone functionDaily operationAlarm and remote monitoringSpecificationPacking listExplanationFor all the issues stated in this manual:     The icon  is only valid for the corresponding alarm host which is configured       with WiFi module.Overall state     The icon  is only valid for the user who has applied alarm service from local      intranet alarm center.Features2.4 inch TFT display screen, concise user interface and menu hint design.Main interface status bar, date/clock indication, fairly obvious alarm host status.Built-in powerful performance CPU master based on 32-bit Cortex-M3 core.Based on uCOS - III operating system with multitasking design, great user operation experience.WIFI/GSM/3G/GPRS intranet alarm system, support different alarm channels, like APP push/SMS/voice monitoring/intranet center etc. to ensure the alarm performance stable and reliable.Support SMS arm/disarm and voice arm/disarmSupport up to 100 learing/storage location for remote control, RFID cards and wireless detector. Support many defense zones, such as gate, SOS, bedroom, window, balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc. Support the main power malfunction, backup power shortage, tamper alarm and other extended alarm.Support entry/exit zone, indoor zone, perimeter zone, 24-hour zone..etc.Up to 5 groups preset alarm phone numbers, SMS on/off and dial on/off can be set respectively.Support external wireless siren.Support timing arm and disarmCan store and inquire daily operation records and alarm records.GSM network clock synchronization, to ensure accurate clock, and support country time zone setting.Support multi-language menu display, voice prompts and alarm SMS setting.Can record 20 seconds voice message and alarm voice.Telephone function, support 5 groups re-dial number.User-friendly APP operation experience and user interface.Push Arm/disarm message to APPSupport APP remote arm/disarm, parameter setting and accessory management.Online GPRS to obtain equipment status, automatic alarm when offline.Reserved remote GPRS TCP / UDP protocol channel, compatible with multiple alarm center networking protocol to facilitate network alarm.Center remote control.1CONTENT OVERALL STATE
Identification for daily operationArmStay ArmDisarmTriggerExit delayEntrance delayAlarmset security task (i.e. Anti-burglar), make the host into alert state, also known as Arming, Alert or Booting. Designate security guard mission(i.e. Anti burglar), set the alarm host into on-guard status, also called Arming Alert or Power on.In case the user is at home, only set alert to entrance/exit or perimeter, also called home alert.Withdraw security task(i.e. Anti-burglar), also called Withdraw alert or Power off.Under Arm state, detector detects someone or door is opened, it will trigger the detectors and make alarms.After setting the host to be Arm state, in order to avoid making alarms for the users leaving and passing the Arm zones, delay the alarm time.When user comes back and pass the Arm zones, the host will not immediately make alarms. It will allow user to Disarm the host with some time; the host will make alarms if time out beyond the Disarm.When the host create alarm action, acousto -optical alarm signal arises. The host will send SMS message to the preset mobile phone, dial the preset user telephone number, create push to mobile phone APP, or send alarm information to intranet security center. , Top viewAlarm host appearance and accessoriesARM/*DISARM/#TFT display screenDial keyPrevious/Function keyNext/Backspace keyReturn/Cancel keyEnter KeyDisarm keyArm keyStay arm keySOS keyBottom viewAnti-tamper switch32OVERALL STATE ALARM HOST APPEARANCE AND ACCESSORIES
08:452016-12-28 Wednesday3 4 5 6 7 812910 11121354Main interfaceSide viewPower on/off/Initialization keyMicrophonePower jackWired siren jackSIM card slotKey of side faceFunctionPower on Power offInitializationDescriptionPress this key, “Welcome” appears in the screen, it means power on.Press and hold this key for 3 seconds to power off.Press this key for 5 times to initialize parametersDescription for main interfaceStatus bar4712111098653DISARM/#ARM/*132108:45GSM signalWiFi wireless networkGSM task statusKeyboard statusPower statusTimeDelay status of clock panelArm/DisarmstatusOn alarmDateKeypadKeyboard quick hintMain status zoneNo SIM cardGPRS networking indicationGSM signal indication1-5 level stands for WiFi signal strength,Gray color means no signalDevice already connected to cloud.The white dot on right corner means the binding mobile phone is online.Sending SMSDialingKeyboard is locked. There is 5- seconds countdown hint.  Gray color means no signal, 1-5 level stands for GSM signal strengthPowered by main powerClock panel shows current timePowered by back up battery, 0-3 level stands for remaining battery capacity.Current timeExit delay status. After armed, the user should leave the site before countdown time ends. When countdown time ends, it enters into arm mode.Entry delay statusentrance into the site before countdown time ends.If the user don’t disarm, it will trigger alarm when countdown time ends.. The user should disarm after ArmStay armDisarmNo alarmAlarm statusCurrent dateCallArm/Stay arm keySOS keyDisarm keyMenu keyALARM HOST APPEARANCE AND ACCESSORIESALARM HOST APPEARANCE AND ACCESSORIESPleas e exitPleas e disarm
Note: 1. When the main keyboard is unlocked, if the user does not do any action or directly *                 press       Key, then the keyboard is locked. After the keyboard is locked, the user                  needs to input password before using the keyboard.            2. When keyboard backlight is off, if the user does not do any action under main interface,                 or directly press       key, then the backlight is off to save power.            3. When certain language is selected, then the operation voice reminder, display and                 alarm SMS all are converted to this language. The alarm host will restart when                 language selection is confirmed.76Menu structureDelaySwitchExit DelayEntry DelaySet Exit delay,refer to “Identification for daily operation”Unit: second,Range:0~65535,Default: 40 secondsSet Entry delay,refer to “Identification for daily operation”Unit: second,Range:0~65535,Default: 30 secondsSiren DurationUnit:minute,Range:0~65535,Default: 3 minutesSet siren durationArm BeepSirenArm SMSKeypad LockBacklightSystemUser简体中文 Set arm beepSelect: On/Off, Default: OffSet SirenSelect: On/Off, Default: OnSet Arm/Disarm SMSSelect: On/Off,Default: OffSet keypad to be locked or notSelect: On/Off,Default: OffSet keypad backlight to be on or offSelect: On/Off,Default: OffSet system passwordRange: 0000-9999, 4 digits, default: 6666Set user passwordPasswordLanguageInitializationReset1st Phone2nd Phone3rd Phone4th Phone5th PhoneEnglishDeutschRestart alarm hostSet system Initialization, refer to “Initialization”Set 1st phone number, Dial on/off, SMS on/offSet 2nd phone number, Dial on/off, SMS on/offSet 3rd phone number, Dial on/off, SMS on/offSet 4th phone number, Dial on/off, SMS on/offSet 5th phone number, Dial on/off, SMS on/offRefer to “Phone number setup”PhoneLogAlarm Log Inquire alarm log historyArm Log Inquire arm/disarm log historyPartsAdd Remoter Learning new remote controlDel Remoter Delete all remote controlRefer to “Add/Delete remote control”Add DetectorLearning new wireless detectorDel DetectorDelete all wireless detectorsRefer to “Add/Delete wireless detector”Add RFIDLearning new RFID cardDel RFID Delete all RFID cardsRefer to “Add/Delete RFID card” Siren Learn Send 1-second wireless learning signal to external wireless siren.Refer to “Synchronization with external wireless siren”WiFiAirlink Set alarm host into wireless network configuration(via APP) Unbind Unbind alarm host with mobile phone APPRefer to “unbind mobile phone APP with alarm host”Refer to “Voice record”RecordRecordPlayRecord and playbackPlay current recorded voiceDelete Delete current recorded voiceArm TimerTimerSet daily arm time and switch on/offDisarm TimerSet daily disarm time and switch on/offRefer to “Clock/Timing”Zone & SyncSet the country or region’s standard Greenwich time difference, which is synchronous to internet time. Default time zone: +08:00.VersionInquire firmware version, serial number, server.MENUSettingMain menuALARM HOST APPEARANCE AND ACCESSORIESALARM HOST APPEARANCE AND ACCESSORIESRange: 0000-9999, 4 digits, default: 1234Simplified Chinese(Default)
Operation Keyboard: Main Menu   Phone  1st Phone, enter into phone number setup menu.Press     to select     Number, input the alarm number (up to 18 digits), and press     to backspace in case of error Press     to select     Dial, press      to select On or Off.If "On" is selected, the panel will dial the alarm number when an alarm occurs.Press     to select      SMS, press     to select On or Off.If "On" is selected, the alarm host will send SMS to this phone when an alarm occurs. Operation Keyboard: Main Menu      Parts     Add Remoter     Enter.The alarm host displays "Synchronize" and enters into the 20- seconds countdown dialog window waiting for the remote control synchronization.Press any key of the remote control to send signal to the alarm host.The alarm host displays "Learning OK" , then the remote control is successfully added.If the alarm host displays “Device code has been learnt”,  it means this remote control is already added to this alarm host, please use other remote control to try again. AddOperation Keyboard: Main Menu       Parts      Del Remoter       Enter.The alarm host displays “Delete Remoter all”, meanwhile all stored remote control’s number is displayed in the dialog window.Press      to confirm, the alarm host displays “Operation OK”, all remote control is deleted.Operation keyboard: Main Menu      Parts      Add Detector     EnterIt enters into “Set Name and Mode” dialog windowPress      to select      Name, and press      to select the corresponding name of the zone where the wireless detector is to be added.Press      to select     , and then press     to select the mode of zone where the wireless detector is located.Select  , When the alarm host is armed or Stay armed, the detector will always alarm if triggered,. Suggest to set this mode of detector in the main door, window, balcony, perimeter area.Select "Out Armed Active", when the alarm host is Out armed, the detector will not alarm if triggered. Suggest to set this type of detector in hall, bedroom area.Select  , the host will alarm at any time once triggered.  Suggest emergency, smoke, gas, carbon monoxide, water leaks and other detectors to be set to this mode.Selecting , the alarm host will not alarm at any time if triggered.For doorbell, please select  , then a tinkling sound arises from the alarm host whenever the doorbell is pressed. "Stay armed Active""24 hours Active" "Close" “Doorbell”Continuously press Power On/Off key for 5 times, the alarm host will restart, then system initialization is finished. After system initialization, all the data including remote control, wireless detector, RFID card, language and time zone and other setting are reset to factory default  .      IP address is cleared and the alarm host is offline GPRS. The IP address needs to be set again to assure the alarm host to go online and connect with intranet center.allSystem initializationStartInitial usageInsert SIM card:Power on :Turn on the alarm host:Turn off the alarm host: According to below diagram, insert MICRO SIM card. When a ticking voice is heard, it means the SIM card is inserted properly.Plug power adaptor into USB 5V jack to turn on power.Press Power On/Off key, a “welcome” window appears, then the alarm host is turned on.Press and hold Power On/Off key for 3 seconds until the screen is off, then the alarm host is turned off.!Description for operation keysPress Previous     and Next key to select menu。Press Return key     to last menu。Press Enter key     to next menu。                 1. When     is used as backspace key, long press     to delete all input information.            2. For the other function which is not mentioned in this paragraph, please refer to the                 description in the “Menu Structure”.            3. Some operation in this paragraph like phone number setup, add/delete remote control,                  add/delete wireless detector and Synchronization with external wireless siren also can                  be realized via APP.!98Please be cautious to use this function. Normally it is only used when user forgets password, or alarm host malfunction, or the parameter is wrongly set, or unknown detector, remote control or RFID card are learnt.Menu operationPhone number setupThe host can set up to maximum 5 groups of alarm numbers, each set of numbers can be set independently of their dial-up switch and SMS switch.Take example as phone number 1:Press      to confirm, the alarm host will display "Setting OK".Add/Delete remote controlDeleteAdd/Delete wireless detector(included doorbell alarm)AddINITIAL USAGE INITIAL USAGE
Operation keyboard: Main Menu      Timer     Disarm Timer Operation keyboard: Main Menu      Timer     Arm Timer Press      to select      Timer, then press the backspace key     to delete the original time.Input the 4-digit scheduled arm time (Hour: Minute).Press      to select     Switch, and press     to select "On/Off".Press      to confirm, the alarm host displays "Setting OK" to complete the setting.Operation keyboard: Main Menu      Record     Record and PlayAt first the alarm host will display “Busy and waiting please”, when it changes to “Recording”, it means start to record voice.After recording is finished, the alarm host displays “Playing”and starts automatic playback.After playback is finished, press     to save. The alarm host displays “Please wait saving”. After a few seconds, “Setting OK”appears, then recorded voice is saved.Operation keyboard: Main Menu      Parts     Siren Learn     EnterPress and hold the Set button on the siren until 2 sound is heard. The siren’s indicator will flash quickly, then it enters into synchronization status.Press      to confir  the alarm host displays “Learn Signal Sent” and send wireless signal to the siren.A long and a short sound arise from the siren, which means successful synchronization.m, Operation keyboard:  Main Menu      Parts     Del RFID      EnterThe alarm host displays “Delete RFID all”, meanwhile all stored RFID card’s number is displayed in the dialog window.Press     to confirm, the alarm host displays “Setting OK”, all RFID cards are deleted.Operation keyboard: Main Menu      Parts     Add RFID     EnterThe alarm host displays "Synchronize" and enters into the 20- seconds countdown dialog window waiting for the RFID card synchronization. Put the RFID card close to the sensitive area on the down-right corner of the alarm host.The alarm host displays "Learning OK", then the RFID card is successfully added.If the alarm host displays “Device code has been learnt”,  it means this RFID card is already added to this alarm host.Press     confirm The alarm host displays "Synchronize" and enters into the 20- seconds countdown dialog window waiting for the wireless detector synchronization.Trigger the wireless detector to launch wireless signal to the alarm host.The alarm host displays "Learning OK", then the wireless detector is successfully added.If the alarm host displays “Device code has been learnt”,  it means this wireless detector is already added to this alarm host , please use other wireless detector to try again. Record alarm voice Arm TimerDisarm Timer!Add/Delete RFID cardAddOperation keyboard: Main Menu      Parts     Delete Detector      EnterThe alarm host displays “Delete detector all”, meanwhile all stored detector’s number is displayed in the dialog window.Press     to confirm, the alarm host displays “Operation OK”, all wireless detector and doorbell are deleted.This operation instruction is subject to our company model PE-519 wireless siren.            After the wireless siren is synchronized with the alarm host, if the alarm host triggers alarm,              alarm sound will arises from the siren at the same time.1110DeleteDeleteSynchronization with external wireless sirenRecordThe user can record 20-seconds voice. If alarm occurs, the alarm host will dial preset phone number and play this record alarm voice.TimerThe users can set automatic arm/disarm time according to their own routine time, avoiding repeated operation or missed arm/disarm.Press      to select      Timer, then press the backspace key     to delete the original time.Input the 4-digit scheduled disarm time (Hour: Minute).Press      to select     Switch, and press     to select "On/Off".Press      to confirm, the alarm host displays "Setting OK" to complete the setting.INITIAL USAGE INITIAL USAGE
Operate alarm host: Main Menu      WiFi     Unbind     Enter, the alarm host displays “Unbinding”.Waiting for 10-20 seconds, the alarm host unbinds with mobile phone automatically. After unbinding, the mobile phone can not control the alarm host until being configured again. Unbind mobile phone APP with alarm host Ensure the alarm host and mobile phone to be in the same WiFi network.Run APP software, and login at the user login interface (new user is required to register ID at first).In “Device List” interface, press “Airlink” button on top right corner to enter into the intelligent configuration interface.Operate alarm host: Main Menu      WiFi      Airlink      Enter, the alarm host displays “Airlinking”, and enters into the 60- seconds countdown waiting interface.Select WiFi network listed in the APP and input password,  press “OK” to start configuration.The alarm host displays “Airlink OK” to complete configuration. The MAC address of the alarm host will appear in the APP “Device List”. One mobile phone can be configured with several alarm hosts. Select the corresponding MAC address of the alarm host, then the mobile can control the alarm host.54InstallMobile phone APPThe concerned APP description is based on Andriod system, some description may differs due to APP version or iOS system. All description is subject to installed APP in mobile phone.321Refer to below diagram:1312APP configuration with alarm hostUsing mobile phone’s browser to scan QR code, then download the APP and install. Add remote control via APPEnter into “System Settings” menuSelect “Remote Setting”, all remote controll is listed in this interface.Select “Add Devices”Select “Start to learn”Press any key in the remote control, the alarm host will send successful information to APP, then learning is completed.Return to “Remote Setting” to add more remote control....“Learn OK” appears in APP. Refer to below diagram:MOBILE PHONE APP MOBILE PHONE APP
612321 312354321541514Add detector via APPEnter into “System Settings” menu.Select “ Detector Setting”, all detectors are listed in this interface.Select “Add Devices”.Press “Detector Name” to select the added detector name.Press “Zone Mode” to select the arm mode.Select “Start to learn”.The alarm host will send successful information to APP, the learning is completed.appears in APP.Return to “Detector Setting” to add more detectors.“Learn OK” MOBILE PHONE APP MOBILE PHONE APPNumber of learnt remote control
Enter into “system settings”, and select “Wireless Siren Setting”.Click “Trigger”, APP will send wireless signal to the alarm host.“Trigger OK” appears, the synchronization is finished.Synchronize external wireless siren via APP21 321 387Delete remote control via APPEnter into Remote Setting  and press       icon.Click OK  to finish deletion in Delete remote controller all  popup windowAPP returns to Remote Setting  menu, then remote number will be zero.“ ” “ ”“ ” “ ” .“ ”?21 31716Delete detector via APPEnter into “Detector Setting” menu, press “      ”icon which you wan to deleteA window “Delete Detectors named....appears, click “OK” to finish deletion.APP returns to “Detector Setting” menu, the deleted detectors will not be listed in this interface..Refer to below diagram:This operation is only to send synchronization signal via APP to external wireless siren which is being learnt. Refer to “Synchronization with external wireless siren”.Refer to below diagram:MOBILE PHONE APP MOBILE PHONE APPNumber of learnt detectorIf number is 0, it means delete successfullyRefer to below diagram:
1.Initialization: All learnt remote control, wireless detector and RFID card are     remained, the other parameter is reset to factory default.    Set SMS contents:2.Format of alarm phone number:   XXXXXX is phone number(Max. 18 digits), A is calling alarm switch(1-on,    0-off). B is SMS alarm switch(1-on, 0-off) . *6666*43*xxxxxxxxxxx,A,BThe user is required to edit SMS message according to below format, and send the SMS message to SIM card in the alarm host.Inquire/set parameter: Set function switch; Set alarm phone; Set delay alarm18Refer to below diagram:Remote SMSParameter setup      *     *       *        *Engineer PasswordAddress Content Address ContentOne SMS message can includes one or more address or content, but it must be separated by * and the first and last data must be *. The address should be founded of 2 digits. One SMS content can include maximum 160 bits. It is suggested to put all contents in one SMS.Address Function Contents and Limit Factory DefaultTimes of redialTimes of auto answering ringRevise user passwordRevise system passwordInitializationSet alarm phone 1Set alarm phone 2Set alarm phone 3Set alarm phone 4Set alarm phone 5Inquire GSM signal strength 1~255 times1~255 times0000~9999 4 digits0000~9999 4 digitsEmpty, refer to Note 1Refer to Note 2Refer to Note 2Refer to Note 2Refer to Note 2Refer to Note 2EmptyOnceOnce(reserved)OffOffOffOffOffEmptySet GPRS server IP addressSet GPRS APNSet NTP IPSet Greenwich time zoneThis operation is only valid for online GPRS. Refer to Not 3This operation is only valid for online GPRS. Refer to Not 4Refer to Note 5Refer to Note 5Note: Below examples are based on default system password 6666MOBILE PHONE APP REMOTE SMS MESSAGE19Enter into System Setting     Switch Setting, there are 3 options(Arming beep, Alarm beep, Arm/disarm SMS) to select On/Off accordingly.Enter into System Setting     Alarm Phone Setting, click “      icon to activate phone calling function when alarming, click “      icon to activate SMS function when alarming.Enter into System Setting     Entry Delay Setting, to select the delay time in the time roll. The unit is second.””21 2
The user can set a name for the alarm host which is used as the prefix of SMS phone number. This helps to recognize the alarm host or specific alarm location.Example: SMS 1234@ , 1234 is password, @ is command, is the name(Max.40 bits)XX Building a BlockXX Building a Block PHONE set:1:      1st alarm phone number, voice alarm switch, SMS alarm switch, general switch2:      2nd alarm phone number, voice alarm switch, SMS alarm switch, general switch3:      3rd alarm phone number, voice alarm switch, SMS alarm switch, general switch4:      4th alarm phone number, voice alarm switch, SMS alarm switch, general switch5:      5th alarm phone number, voice alarm switch, SMS alarm switch, general switchREDIAL COUNTER:Redial times of voice alarmDELAY set:ENTRY: Entry delay(unit: second)EXIT: Exit delay(unit: second)SIREN: Siren duration(unit: minute)SWITCH set:ARM/DISARM BEEP:              Arm/Disarm switching beep(1:on, 0:off)ALARM BEEP: Siren alarm beep(1:on, 0:off)ARM/DISARM SMS:              Arm/Disarm SMS switch(1:on, 0:off)DETECTOR learned:REMOTE: Number of remote controlDETECTOR: Number of detectorRFID:                                                   Number of RFID card           SYSTEM set:SN: Alarm host serial numberLANGUAGE: Alarm host languageENGINEER PASSWORD: Engineer passwordUSER PASSWORD: User passwordGSM CSQ: GSM signal strength                                                                (0 or 99 means abnormal strength)WIFI RSSI: WiFi signal strengthExample: Set 2 alarm phone numbers as 13912345678 and 075581234567.                    13912345678 is used to receive calling and SMS alarm, 075581234567                    is used to receive calling alarm, then please set SMS contents                    according to below format:                        *6666*5113912345678,1,1*52075581234567,1,0*3、Format of IP address: :     aaa,bbb,ccc,ddd is IP address, xxxxx is the port, separated with comma.     Example: Set GPRS server IP address as 11 6.62.42.223, port is 2001,                     then please set SMS contents according to below format:                      4、Set GPRS APN     Example: The local GPRS APN is internet.beeline.kz, then please set                     SMS contents according to below format:                      5、Set Greenwich time zone:Set auto synchronization between alarm host       clock and internet time. Time difference zone  : -12.0~13.0aaa,bbb,ccc,ddd,xxxxx*6666*90116,62,42,223,2001*  *6666*92internet.beeline.kz*rangeAlarm host name setupSMS format:*6666*62*,Alarm host feedback SMS:SYSTEM set2:APN: GPRS nameGPRS IP: GPRS server IP address and portNTP: Internet time server domainTIME ZONE: GMT standard time zoneSERVER                       Current WiFi server:!2120Parameter inquiryAll feedback SMS contents are written in English, please inquire according to below description.Inquire system settingSMS format:*6666*90*,Alarm host feedback SMS:Inquire system setting2SMS format:*6666*51*,Alarm host feedback SMS:Alarm phone setup inquirySMS format:*6666*33*,Alarm host feedback SMS:Delay setup inquirySMS format:*6666*46*,Alarm host feedback SMS:Switch setup inquirySMS format:*6666*26*,Alarm host feedback SMS:Remote control/detector/RFID card inquiryREMOTE SMS MESSAGEREMOTE SMS MESSAGE
Canc el O KBy remote control: By keyboard: By RFID card: By remote SMS: By APP: The alarm host reminder: press 【     】key to activate Out Arm.In Main Interface, press      to activate Out Arm.In Disarm mode, put the RFID card close to the sensitive area on bottom right corner of the alarm host.Send SMS message 1234#1(1234 is user password) at first, then the alarm host will feedback “System Armed!  SMS to mobile phone to confirm.In Main Menu, select “       icon, then select delay arm time(exit delay). After around 3 seconds, Out Arm mode is completed.A reminding voice “System armed” will be heard, the Main Interface displays “Armed” and “Please exit”, and an exit time progress bar appears. The user should leave the alarm zone before exit time. If Arm/Disarm SMS switch is on,the preset phone will receive “Sytem Armed!”SMS.””The use r ca n co ntr ol t he a lar m ho st b y any of f oll owi ng w ays:  Re mot e co ntr ol, Key boa rd, RFI D ca rd.  Re mot e SM S.         Mo bil e ph one APP.         GP RS a lar m ce nte r.21 3Under Out Arm mode, all defense zones are on alert status. If any defense zone is triggered, the alarm host will generate a local siren alarm, and send alarm SMS or make calling to the preset phone numbers , simultaneously send the alarm message to mobile phone APP or GPRS alarm center.!ARM/*In Main Interface, press      key to make calling.Please operate according to the hint in this interface.!2322Phone functionIn case of following condition, No GSM network, in Arm mode, on alarm, making a call is forbidden.Daily operationOut ArmRefer to below diagram:1008610086PHONE FUNCTION DAILY OPERATIONOn-time status of alarm host
By remote control:By keyboard:By APP: The alarm host reminde:  Press         key to activate SOS. In Main Interface, press      to activate DisarmIn Main Menu, select  icon.The Main Interface displays “Help”. The alarm host will generate a local siren alarm, and send alarm SMS or make calling to the preset phone numbers , simultaneously send the alarm message to mobile phone APP or GPRS alarm center.“        ”SOS21<The alarm host name>:Remote operation resultSOSBy remote control: By keyboard: By APP: The alarm host reminder:Press     key to activate Stay Arm.In Main Interface, press      key for twice to activate Stay Arm.In Main Menu, select “     ” icon. After around 3 seconds, Stay Arm mode is completed. A reminding voice “System armed” will be heard, the Main Interface displays “Stay Armed”. If Arm/Disarm SMS switch is on,the preset phone will receive “System Stay Armed! ”SMS. 21ARM/*By remote control: By keyboard: By RFID card:By remote SMS: By APP:The alarm host reminder: Press     key to activate DisarmIn Main Interface, press      to activate Disarm In Arm/Stay arm mode, put the RFID card close to the sensitive area on bottom right corner of the alarm host.Send SMS message 1234#2(1234 is user password) at first, then the alarm host will feedback “System Disarmed!“ SMS to mobile phone to confirm. In Main Menu, select “     ” icon. After around 3 seconds, Disarm mode is completed.A reminding voice “System Disarmed” will be heard, the Main Interface displays “Disarmed”. If Arm/Disarm SMS switch is on,the preset phone will receive “System Disarmed!”SMS.DISARM/#!2524Stay Arm!Under Stay Arm mode, only valid Stay Arm defense zones are on alert status. If any defense zone is triggered, the alarm host will generate a local siren alarm, and send alarm SMS or make calling to the preset phone numbers , simultaneously send the alarm message to mobile phone APP or GPRS alarm center.Refer to below diagram:DisarmUnder Disarm mode, all the alarm procedure will be terminated. Refer to below diagram:SOSRefer to below diagram:SMS notification feedbackDAILY OPERATIONDAILY OPERATIONOn-time status of alarm host21On-time status of alarm hostOn-time status of alarm host
When any alarm is triggered, the alarm host will send SMS to preset phone numbers as following contents:!The alarm host supports diverse alarm types. When alarm is triggered, it will send alarm SMS to the user ’s mobile phone and push alarm message to APP, simultaneously send alarm message to GPRS alarm center and make calling to the user, then the user can do on-time monitoring and remote operation.The alarm host also support following alarm types,    The main power malfunction(when main power malfunction lasts for 5 seconds,         the alarm is activated)    Back up battery shortage(In case of main power malfunction, when back up        battery’s voltage is lower than 3.45V and lasts for 10 seconds, the alarm is        activated)    Main power recovers.      Anti-tamper alarm(When the mounting bracket is separated with the alarm host,        the alarm is activated). <The alarm hostt name>:Current alarmAutomatic dialing preset phone number when the alarm host alarms21 3When any alarm is triggered, the alarm host will send alarm message to GPRS alarm center. The alarm center can handle the alarm quickly after receiving and confirming the alarm message.2726SMS alarmAlarm and remote monitoringVoice alarm and remote monitoringWhen any alarm is triggered, the alarm host will automatically dial preset phone numbers(make sure the dial switch is on). After the user ringed, the alarm host will play current alarm type at first. If there is a preset voice, this voice will be played. Then the user will hear reminding voice “Press 1 to arm, press 2 to disarm, press 3 to monitor, press 4 to talk . If it is mistake alarm, the user can press “2” to activate Disarm. The user also can press “3” or “4” to turn off the alarm sound for better monitoring. If monitoring is unnecessary, just quit calling. If the user does not answer the call or failed calling, the alarm host will constantly dial the preset phone number according to the preset redial times until the user answers the call.”Preset phone number to call alarm hostIf the preset phone number voluntarily calls the alarm host, the alarm host will automatically answer the call, then the user can do on-time monitoring and remote operation.Alarm receiving procedure via APPWhen any alarm is triggered, the alarm host will push alarm message to mobile phone at first. Open APP and enter into main menu, the user can see a red alarm icon in the middle status bar and the current alarm type. The user can select “Alarm Log” icon to inquire all operation record and alarm log.Receiving alarm by Intranet monitoring center Refer to below diagram:The function is only valid when the IP address is correctly set. Proper APN setting is required for foreign countries. Please refer to “SMS parameter setup” for details.ALARM AND REMOTE MONITORING ALARM AND REMOTE MONITORING
Input voltage: DC5V(micro USB jack)Working current: <120mAStandby current:<80uASiren output:<500mAWireless frequency: 433MHzWireless coding: EV 1527GSM bands: 850/900/1800/1900MHzWiFi standard: IEEE802.11b/g/n wireless standardBack up battery: 3.7V/300mAh lithium batteryWorking temperature: :0~55℃Relative humidity: < 80%RH (No freezing)Product dimension:185x125x14.7MM(LxHxT)Alarm host  x1Micro USB 5V/1000mA Power adapter  x1Wireless PIR detector  x1Door sensor  x1Remote control  x2RFID card   x2Wired siren   x12928Specification Packing ListTECHNICAL PARAMETER PACKING LIST
BelindaDate:PG-103PG-103公司标准英文说明书V 1 .0封面128铜 板纸(表面 过哑膜)内页70G双胶 纸120*180MM封面封底四 色内页单色Mar.4th,2017品        号CMYK
 1 1.  WarningThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different
 2 from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. NOTE: This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter. RF Exposure Statement To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance of 10mm the radiator your body.   This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. RF Exposure Information:   The SAR limit of USA (FCC) is 1.6W/kg averaged over one gram of tissue. Device Types (FCC ID: 2AIT9PG-103) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certification for use when properly worn on the body is 0.622 W/kg .Simultaneous RF exposure is 0.679W/Kg. This device was tested for typical body‐worn operations with the back of thehandset kept 5mm from the body.To maintain compliance with FCC RF exposure requirements, use accessories that antain a 0mm separation distance between the user's body and the back of thehandset. The use of belt clips, holsters and similar accessories should not containmetallic components in its assembly.
 3 The use of accessories that do not satisfy theserequirements may not comply with FCC RF exposure requirements, and should beavoided. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly.   The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

Navigation menu