SZ PGST PG101 GSM anti-theft alarm controller User Manual

SZ PGST CO., LTD GSM anti-theft alarm controller

User Manual

Download: SZ PGST PG101 GSM anti-theft alarm controller User Manual
Mirror Download [FCC.gov]SZ PGST PG101 GSM anti-theft alarm controller User Manual
Document ID3310132
Application IDvoGejGHN7SUiWXsv9CkVqA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize163.92kB (2048966 bits)
Date Submitted2017-03-08 00:00:00
Date Available2017-03-09 00:00:00
Creation Date2017-03-03 03:07:19
Producing SoftwareCorel PDF Engine Version 14.0.0.653
Document Lastmod0000-00-00 00:00:00
Document TitlePG-101英文说明书-公司标准版V1.1 20170223.cdr
Document CreatorCorelDRAW
Document Author: Administrator

User manual
GSM anti-theft alarm controller
Scan QR code here
download and install APP
Android
App Store
99+8 DEFENSE ZONES
GSM anti-theft alarm controller
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Contents
Preface.......................................................................................................... 3
24. Host Logs Deleting ....................................................... ........................... 21
Function Introduction.................................................................................... 4
25. SMS Notification of Arm/Disarm.............................................................. 21
Alarm Host Installation.................................................................................. 5
26. System Clock Setting............................................................................... 22
Installation and Use of Infrared Detector...................................................... 7
27. SMS Phone Number Setting.................................................................... 23
Installation and Use of Magnetic Door Sensor.............................................. 8
28. SMS Phone Number Deleting.................................................................. 23
Functions Setting........................................................................................... 9
29. Alarm Phone Number Setting................................................................... 24
1. Initialization............................................................................................... 9
30. Alarm Phone Number Deleting................................................................. 24
2. System Setting........................................................................................... 9
31. Defense Zone Alarm Type Setting........................................................... 25
3. Exit Setting................................................................................................. 9
32. Host GSM Signal Checking...................................................................... 26
4. Coding of Remote Controller Setting......................................................... 9
33. LCD Backlight Duration Setting ...................................................................
26
5. Remote Controller Deleting Setting........................................................... 10
34. Sound Volume Setting ............................................................................. 27
6. Coding of Wireless Detector Setting ........................................................ 10
35. Language Setting .................................................................................... 27
7. Single Wireless Detector Deleting Setting ................................................ 11
Mobile APP Operation ................................................................................... 28
8. All Wireless Detectors Deleting Setting .................................................... 11
Daily Operation ............................................................................................ 31
9. Alarm Type Setting .................................................................................... 12
Out Arm.................................................................................................... 31
10. Wireless Siren Coding Setting ............................................................... 14
Stay Arm................................................................................................... 32
11. Remotes Operation Voice Prompt Setting............................................... 14
Disarm...................................................................................................... 33
12. Siren Ring Time Setting........................................................................... 15
Answer Alarm Call.................................................................................... 33
13. Arm Time Delay Setting.......................................................................
15
Remote Control by SMS........................................................................... 34
14. Defense Zone Alarm Time Delay Setting.............................................
16
Remotely Control..................................................................................... 34
15. Telephone Dial-up Cycle Times Setting................................................... 16
SOS.......................................................................................................... 34
16. Remote Call Ringing Times Setting......................................................... 17
Maintenance.................................................................................................. 35
17. Recording Setting.................................................................................... 17
Technical Parameters 1、2............................................................................ 36
18. Password Change Setting....................................................................... 18
Technical Parameters 3 ................................................................................ 37
19. Host Keypad Lock Setting........................................................................ 19
20. Host Timing Arm/Disarm Enable/Disable Setting ................................... 19
21. Host Timing Arm/Disarm Setting ............................................................. 20
22. Host Reset Setting................................................................................... 20
23. Host Logs Inquires .................................................................................. 21
-1-
-2-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Preface
Function Introduction
Thank you for choosing the wireless alarm system product of our company.
Apply advanced mobile communication technology, support SMS and dialing alarm, etc.
Wireless alarm system adopts the most advanced digital sensing and controlling
8 wired defense zones and 99 wireless defense zones.
technologies, it is the intelligent alarm control system containing burglar alarm, fire alarm, fire
fighting, gas leakage and SOS.
Wireless alarm system uses the most advanced multiple random selection technology, it
avoids the problems of interference and alarm missing which usually exist in the similar
systems. This system can be used widely in residence, shops, villa, small enterprise and so on.
For your safety, before installing and using, we suggest you read this manual carefully.
At most 5 wireless remotes to be coded.
LCD display. Built-in clock. Operate easily.
Sound prompt for all operations.
Live voice installation setting and daily operations are much easier.
SMS prompt when AC power lost or recovered.
Built-in intercom horn, walkie talkie can be realized.
Built-in wireless transmitting module, could be coded with smart home appliance.
Arm and Disarm timing function.
Can store 6 groups of phone numbers: when alarming, system will make alarm call to these numbers
automatically.
Can store 2 groups of SMS numbers: when alarming, system will send alarming SMS automatically.
Can inquire host status by SMS
Can set 0-99 seconds delayed alarm for single defense zone
10-second recording, automatically play when alarm comes.
Built-in digital voice announcer, automatically broadcast the alert-situation during the alarm .
Built-in Chinese/English SMS message, can send out alarm message automatically when alarm.
Users can make calls by using keypad on alarm
Additional functions: can be used as a mobile, can realize the functions of dialing, bill query, and
phone recharge.
One-key-control function: Out Arm, Stay Arm, Remote Arm; with Real-time, 24 hours, bypass defense
zones programming function.
Wireless coding: easy and quick to add additional wireless accessories. Remote control Arm, Disarm,
Monitor, and Intercom by phone.
Remote control Arm, Disarm, Monitor, and Intercom by phone.
Event Log Query: host automatically records 10 pieces of alarm information
Multi-type of arm: Remote control arm, out arm, stay arm, timed arm, arm by phone remotely.
Built-in lithium polymer: make alarm when power off.
Compatible with the protocol of international normal Central Station Recivers, CID alarm
communication protocol.
-3-
-4-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Alarm Host Installation
wire connecting terminal:
ZONE 8
Z8
GND GND
ZONE 7
Z7
GND GND
ZONE 6
Z6
ZONE 5
Z5
ZONE 4
Z4
GND GND
ZONE 3
Z3
GND GND
ZONE 2
Panel schemes:
Z2
avoid steel-reinforced concrete and fire-proof doors.
ZONE 1
receiving effect from all wireless detectors. Please note that keep the host away from largesized metallic objects and home appliances producing high-frequency interference; Meanwhile
Z1
The host shall be installed in the center of the prevent site which could realize best
Front of the host
For NO connection
For NC connection
Power indicator(light)
Wired accessories B
LCD
Arm indicator
GSM signal indicator
Wired accessories A
+ Positive
Arm
Negetive
+ Positive
NO NC COM
Alarm indicator
NO NC COM
- Power supply
Negetive
- Power supply
Disarm
Dial-up key
SOS
LCD display:
Alarm icon
Back of the host
Status icon
Arm/Disarm
Clock/Defence
Built-in horn
MIC
Power adaptor port
Power switch
SIM slot
TF slot
Wired siren port
Fire Alarm SOS
Gas
Alarm
Hall
Alarm
Window Balcony
Alarm
Alarm
Locks
Alarm
Perimeter
Alarm
Wired defense zone
-5-
-6-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Installation and Use of Infrared Detector
Please tear off the plastic insulating tape before use. Installation height is about 2.2 meters
Installation and Use of Magnetic Door Sensor
Door sensor is installed on the door. First clean a right place of the door, take out the sensor
from the ground, should be installed in a corner indoors to obtain the ideal detection range, at
and then stick a double-sided adhesive at the bottom. Should pay attention to the following
the same time should be an angle with walking line indoors (The detection effect is best with
when installing.
people’s walking direction into 90 - degree angle).
1.The transmitter(sensor body) and the magnetic bar should be installed separately, that is,
Installation method: Take out the bracket & base attached, insert the bracket into the slot of
the bottom of the PIR housing; fix the base firmly with two pieces of the screw, and insert the
bracket into the slot on the back of PIR detector and fix well.
the body should be installed on the fixed frame and the magnetic bar should be installed on the
mobile door. (Notes: emitter indicator light nears the bar. ).
2.The magnet is installed apposite the transmitter, the distance between them should not be
more than 1 cm.
As shown below:
1.To determine the installation location
The recommended installation height
is 2.2m from the ground.
3.After installation, the indicator light flashes one second while opening the door which
2.To fix the PIR detector
Fix the mounting bracket into the wall with
screws, and insert the bracket into the slot
on the back of PIR detector and fix well.
means installation is available. Indicator light flashes 3 times which means the low power of the
battery, should replace the battery in time.
Ground
Should pay attention to the following with infrared
detector installation:
1.Avoid the detector facing out of the window;
2.Within coverage of detection, there shall not be obstruction, such as shield, furniture, large
potted plants etc.
3.Avoid more than one detector in the same place, as they will possibly intervene with each
other by triggered simultaneously.
4.To avoid facing the window, cooling or warming machines, or other appliances that might
cause prompt temperature change and thus cause false alarm.
5.The detector needs about 3 minutes to perceive the surrounding environment after turn on,
then can arm or disarm by remote controller.
6.The detector needs several seconds to analyse and confirm when it detects the invasion
body, then release the alarm signals, thus can avoid false or missing alarm.
7.PIR detector is only for indoor use. ( Prohibit installing outdoors).
-7-
Notes:
Please check whether the signal between door sensor
and alarm host is OK or not before fix the device; if
install on a metal door, to block up the bottom of
sensor to avoid shielding the signal; this product is
not suitable with the roller shutter, please buy the
special device if you need.
-8-
GSM anti-theft alarm controller
Function Setting
1.Initialization
GSM anti-theft alarm controller
Operating method: [21]
[#]
LCD display:
Please insert SIM card and power on the system by adapter, built-in speaker would make a
sound, and all icons display on the LCD, the time shows normally after all LED indicators are
ON. Signal mark with 5 grids on screen in 10 seconds means host starts up normally with
strong GSM signals. Also check whether the signal indicator flashes once every 2s; Finally,
move the backup battery switch to ON.
Notes: The same remote controller
could be coded just once.
You can add maximum 5 remote
controllers.
2 . System Setting
Input 4-digit administrator password on the host and press [#] button to confirm. You will
hear a voice prompt: please enter instruction. At the same time,[- - - -]displays on the screen,
indicating the system enters setting status. You can perform different settings repeatedly as
long as the system keeps in setting status. The system will exit setting mode and return to
normal status in 35s once you stop doing any operations.
5 . Remote Controller Deleting Setting
In setup state, use keypad to enter [22], then press [#] to confirm. The host makes a “tick”
Notes: The system default administrator password is [6666].
Operating method: [XXXX] [#]
X indicates: 4-digit admin password
LCD display:
sound, and then a voice prompts “setting completed”.
Operating method: [22]
[#]
LCD display:
3 . Exit Setting
Press [*] button if you want to exit setting state after finishing setting or return to former
operation, the host would make a “tick” sound and setting is finished.
Operating method: press [*] button
6.Coding of Wireless Detector Setting
4.Coding of Remote Controller Setting
In setup state, input number [21] , then press [#] to confirm. The host make a “tick” sound
and you will hear “remote control coding” .the [ ] indicator is on without flashing; Press any
button on the wireless remote controller, The host makes a “tick” sound, and then a voice
prompts “setting completed”. [ ] indicator goes out, indicating the remote controller succeeds
in coding. The code of next remote controller will be displayed on the LCD screen
automatically, when coding completed.
-9-
In setup state, input number [23], and input the defense zone number you want to code
[02~99], and then press [#] to confirm. LCD would show the defense zone accordingly. You will
hear a voice prompt “detector coding”. Then trigger a wireless detector to emit a wireless
signal; after receiving the signal, the host makes a “tick” sound, and then a voice prompts
“setting completed”. , the [
] indicator goes out at the same time.
-10-
GSM anti-theft alarm controller
Operating method: [23] [XX] [#]
XX Indicates:02~99 defense zones number
GSM anti-theft alarm controller
Operating method: [25]
[#]
LCD display:
Example: Code defense zone 02
Operating method: [23] [02] [#]
LCD display:
7 . Single Wireless Detector Deleting Setting
In setup state, enter number [24] and then press the [02~99] defense zone number which
needs to be deleted, finally press [#] to confirm. The host makes a “tick” sound, and then a
voice prompts “setting completed”. Notes: The deleted sensor for zone would be invalid, so
think it over before you want to delete.
Operating method: [24] [XX] [#]
XX indicates:02~99 defense zones number
Example:Delete defense zone 02
Operating method: [24] [02] [#]
LCD display:
9.Alarm Type Setting
9.1 There are 4 Defense Types:
Detector alarm type is set to “0”: This detector will not trigger the host to alarm in any status.
Detector alarm type is set to “1”: This detector will trigger the host to alarm whether in Out
Arm or Stay Arm state.
Detector alarm type is set to “2”: This detector will trigger the host to alarm only in Out Arm
state; host is in Stay Arm state, the detector cannot trigger
the host to alarm.
Detector alarm type is set to “3”: This detector will trigger the host to alarm in any status.
9.2 Wireless Detector Alarm Type Setting
In setup state, input number [26], and then press the defense zone number [02~99] and then
input detector alarm type [0~3], finally press [#] to confirm.The host makes a “tick” sound, and
then a voice prompts “setting completed”.
8.All Wireless Detector Deleting Setting
In setup state, enter number [25], finally press [#] to confirm. The host makes a “tick” sound,
and then a voice prompts “setting completed”. Notes: The deleted sensor for zone would be
Operating method: [26]
[XX]
[Y]
[#]
XX indicates: two-digit defense zone number
Y indicates: one defense zone alarm type
Example: setting 02 defense zone alarm type to be Out Arm or Stay Arm
invalid, so think it over before deleting.
-11-
-12-
GSM anti-theft alarm controller
Operating method: [26]
LCD display:
GSM anti-theft alarm controller
[02]
[1]
[#]
10 . Wireless Siren Coding Setting
In setup state, input [28]+8-digit wireless siren coding, then enter [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”.
Note: Wireless equipment coding includes sc2262 coding four data bits & 8 address bits.
Operating method:[28]
[XXXXXXXX]
[#]
XXXXXXXX indicates:8-digit wireless siren coding
Example: detailed operating of wireless equipment coding is“01020102”
Operating method:[28]
[01020102]
[#]
LCD display:
9.3 Wired Detector Alarm Type Setting
In setup state, input number [47], and press the defense zone number[81~88] and then input
[0~3] about detector alarm type, finally press [#] to confirm. The host makes a “tick” sound, and
then a voice prompts “setting completed”.
Operating method: [47] [XX] [Y] [#]
XX indicates: two-digit defense zone number
Y indicates: one defense zone alarm type
Notes: wired defense zone of Z1 is equal to zone of 81, wired defense zone of Z2 is equal
to zone of 82, wired defense zone of Z8 is equal to zone of 88 in turn
11 . Remotes Operation Voice Prompt Setting
In setup state, input number [31], and then input [ 0/1 ] , finally press [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”. Factory defaults: turn on
Example: alarm type about defense zone of Z2 is set to Out Arm or Stay Arm
the voice
Operating method: [47]
Operating method:[ 31]
[82]
[1]
[#]
LCD display:
[X]
[#]
X =“0” indicates:Voice prompt turns off
X =“1” indicates:Voice prompt turns on
Example: Turn on remotes voice prompt
Operating method:[31] [1] [#]
LCD display:
-13-
-14-
GSM anti-theft alarm controller
12.Siren Ring Time Setting
In setup state, enter [32], then input time [00~15] minutes, finally press [#] to confirm; The
host makes a “tick” sound, and then a voice prompts “setting completed”. Default: 3 minutes
Operating method: [32] [XX] [#]
XX indicates: siren ring time, unit: minute
Example: Set 2 minutes of siren ring time
Operating method: [32] [02] [#]
LCD display:
GSM anti-theft alarm controller
14.Defense Zone Alarm Time Delay Setting
In setup state, enter [34], then input defense zone [02~99], last input delayed time [00~99]
seconds, press [#] to confirm; The host makes a “tick” sound, and then a voice prompts “setting
completed”. Default: no delay
Operating method: [34] [XX] [YY] [#]
XX indicates:Defense zone
YY indicates:Delayed alarm time, unit: second
Example: Detailed operating of 5 seconds delayed alarm time for defense zone 05
Operating method: [34] [05] [05] [#]
LCD display:
13 . Arm Time Delay Setting
In setup status, enter [33], then input delayed time [00~99] seconds, finally press [#] to
confirm; The host makes a “tick” sound, and then a voice prompts “setting completed”. Thus
15.Telephone Dial-up Cycle Times Setting
In setup state, enter [35], then input dial-up times [00~09], finally press [#] to confirm; next
the host makes a “tick” sound, and then a voice prompts “setting completed”. Default: 9 times
arm time delayed setting is finished
Operating method: [33] [XX] [#]
XX indicates:Arm delayed time, unit: second
Example: detailed operating of 2 seconds delayed time arm
Operating method: [33] [02] [#]
LCD display:
-15-
Operating method: [35] [XX] [#]
XX indicates: Telephone dial-up cycle times
Example: Detailed operating about 2 cycle times
Operating method: [35] [02] [#]
LCD display:
-16-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
16.Remote Call Ringing Times Setting
In setup state, enter [36], then input ringing times [0~9], finally press [#] to confirm; The host
makes a “tick” sound, and then a voice prompts “setting completed”. Default: 6 times
Operating method: [36]
[X]
[#]
X indicates:ring times;
Example: Detailed operating of 2 times remote call ringing
Operating method: [36]
[2]
[#]
Notes: The host remote control is closed, when ringing times is set to 0
LCD display:
18.Password Change Setting
18.1Change User Password
In setup state, use keypad to input [38], then input the 4- digit new password, finally press [#]
to confirm. The host makes a “tick” sound, and then a voice prompts “setting
completed”.Default:1234.
Operating:[38] [XXXX] [#]
XXXX indicates:the new 4-digit password
Example: change the system password to 1012
Operating: [38] [1012] [#]
LCD display:
17.Recording Setting
In setup state, use keypad to input [37], and then press[#] to confirm. The host will emit a
“tick” sound and the [
] indicator is on, and after 10 seconds count down, recording starts:
18.2Change Administrator Password
In setup status, use keypad to input [39], then input the 4- digit new password, and then
press [#] to confirm. The host makes a “tick” sound, and then a voice prompts “setting
record at 30cm away from the host with moderate tone; 10 seconds later, the host will make a
completed”.Default:6666
“tick”sound, indicating the recording finish. Meanwhile, the recorded voice will replay.
Operating: [39] [XXXX] [#]
XXXX indicates: the new 4-digit password
Example: change the system password to 2846
Operating: [39] [2846] [#]
Operating method: [37]
LCD display:
[#]
LCD display:
Notes: The user password and
the Administrator password
cannot be the same.
-17-
-18-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
19.Host Keypad Lock Setting
In setup state, enter [40], then input [0/1], finally press [#] to confirm. The host makes a “tick”
21. Host Timing Arm /Disarm Setting
In setup state, enter [42], and then input disarming time [AABB], and then input arming time
sound, and then a voice prompts “setting completed”.
[XXYY], finally press [#] to confirm. The host makes a “tick” sound, and then a voice prompts
Operating: [40]
“setting completed”.
[X]
[#]
X=“0” indicates: off
Operating: [42]
X=“1” indicates: on
[1]
[#]
[#]
Example: set disarming to 8:20 and arming time to 20:30
Operating: [42]
LCD display:
[XXYY]
“XXYY” indicates: arming time—hour and minute
Example: Open the keypad lock
Operating: [40]
[AABB]
“AABB” indicates: disarming time—hour and minute
[0820]
[2030]
[#]
LCD display:
20.Host Timing Arm/Disarm Enable/Disable Setting
In setup state, enter [41], then choose on/off auto Arm or Disarm function key[1/0], finally
press [#] to confirm. The host makes a “tick” sound, and then a voice prompts “setting
completed”. Factory default: off.
22.Host Reset Setting
Operating: [41]
then a voice prompts “setting completed”.(Remote controllers and detectors would not be
[1/0]
[#]
In setup status, first enter [43], then press [#] to confirm. The host makes a “tick” sound, and
X=“0” indicates: off
deleted).
X=“1” indicates: on
Operating: [43]
Example: Turn on timing Arm/Disarm function
Operating: [41]
[1]
[#]
LCD display:
[#]
LCD display:
-19-
-20-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
23. Host Logs Inquires
LCD display:
In setup state, first enter [44], then press [#] to confirm; The host will make a “tick” sound and
then enter into records list. Press “2” to page up and press “8” to page down. There are 10pcs of
alarm logs in total.
Operating: [44]
[#]
LCD display:
26. System Clock Setting
In setup state, use keypad to input [48], then input the last 2 digits [YY] of the present year,
24. Host Logs Deleting
In setup state, first enter [45], then press [#] to confirm. The host makes a “tick” sound, and
then a voice prompts “setting completed”. Thus host logs are removed.
Operating: [45]
[#]
and then the 2 digits [MM] of the month, and then the two digits [DD] of the date, and then the
two digits [hh] of the hour (24-hour system), and then the two digits [mm] of the minute, and
finally enter [#] to confirm. You will hear a “tick” sound and a voice prompt: “setting completed”.
Operating: [48]
[YY]
[MM]
[DD]
[hh]
[mm]
[#]
“YY” indicates: the last 2 digits of the present year
LCD display:
“MM” indicates: the 2 digits of the present month
“DD” indicates: the 2 digits of the present date
“hh” indicates: the 2 digits of the present hour(24 hour system)
“mm” indicates: the 2 digits of the present minute
Example: set the time as 17:30, June, 12th, 2012
Operating: [48]
[12]
[06]
[12]
[17]
[30]
[#]
LCD display:
25.SMS Notification of Arm/Disarm
In setup state, first enter [46], then choose command key[0/1], that means whether to send
SMS to the user when Arm or Disarm, finally press [#] to confirm. The host makes a “tick”
sound, and then a voice prompts “setting completed”. Default: not send
Operating: [46]
[X]
[#]
“X=1” indicates: send.
“X=0” indicates: not send
Example: send out SMS to user's mobile phone
Operating: [46]
-21-
[1]
[#]
-22-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
LCD display:
27.SMS Phone Number Setting
In setup state, enter [49~50], then input phone number, finally press [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”.
Note: input [49] to set the first SMS phone number, input [50] to set the second SMS phone
Operating: [XX]
[YY…YY]
[#]
XX indicates: address code [49-50] of 1-2 group SMS alarm phone number
YY…YY Indicates: phone number
Example: set 13911112245 to be the first group alarm phone number
Operating: [49]
[13911112245]
[#]
LCD display:
29.Alarm Phone Number Setting
In setup state, enter [51] ~ [56], then input phone number, finally press [#] to confirm. The
host makes a “tick” sound, and then a voice prompts “setting completed”.
Operating: [XX]
[YY…YY]
[#]
XX indicates: address code [51] ~ [56] of 1-6 group alarm phone number
Notes: Only the pre-set alarm
phone number can realize
remote control.
YY…YY indicates: phone number
Example: set 13811110751 to be the first group alarm phone number
Operating: [51]
[13811110751]
[#]
LCD display:
28.SMS Phone Number Deleting
In setup state, enter [49~50], finally press [#] to confirm. The host makes a “tick” sound, and
then a voice prompts “setting completed”.
Operating: [49]
[#]
Example: Deleting the first SMS alarm phone number
Operating: [49]
[#]
30.Alarm Phone Number Deleting
In setup state, enter [51] ~ [56], then press [#] to confirm. The host makes a “tick” sound, and
then a voice prompts “setting completed”.
Operating: [XX]
[#]
XX indicates: address code [51] ~ [56] of 1-6 group alarm phone number
-23-
-24-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Example: deleting the first group alarm phone number
Operating: [51]
[#]
32. Host GSM Signal Checking
In setup state, enter [62] and then press [#] to confirm. The host makes a “tick” sound, and
LCD display:
then a voice prompts “setting completed”. GSM signal value is displayed.
Operating: [62]
[#]
LCD display:
31.Defense Zone Alarm Type Setting
In setup state, first input address code [60] , choose the corresponding defense zone code
[02~99] , and then input [1~8] defense zone alarm type, finally press [#] key to confirm. Voice
prompts: setting completed.
Operating: 【60】 【XX】 【 A 】 【 # 】
XX indicates defense zone code: [02~99] matching 02 to 99 defense
zones correspondingly
A represents alarm type: [1] SOS Alarm, [2] fire alarm, [3] gas leak alarm,
[4] door lock alarm, [5] hall alarm, [6] window alarm,
[7] balcony alarm, [8] perimeter alarm.
Example: set defense zone 10 to be fire alarm type
Operating: 【60】 【 10 】 【 2 】 【 # 】
33. LCD Backlight Duration Setting
In setup state, enter [63] and input [00-99] seconds, then press [#] to confirm. The host
makes a “tick” sound, and then a voice prompts “setting completed”. Default time: 20 seconds.
Operating: [63]
[XX]
[#]
XX indicates: backlight lasting time
Example: set time to 49s
Operating: [63]
[49]
[#]
LCD display:
LCD display:
-25-
-26-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
34.Sound Volume Setting
In setup status, enter [64],then input volume level [0~9],press [#]to confirm. Once the host
makes a “tick” sound, you will hear a voice prompt“setting completed”.Default level “6”.
Operating method: [64]
[X]
[#]
Mobile APP Operation
The system can be controlled by APP. iOS mobile will map to SMS interface, Android mobile
won’t map to SMS interface, but will finish the SMS operation in background.
X indicates: volume level
Example: level 2
Operating:[64]
[2]
[#]
Note: If the volume level is set“0”,then no sound.
Download APP
iPhone user enter the APP Store, search "GSM alarm system"then download and install this
LCD display:
software.
Android user enter Google Play or Android market (China mainland), search “GSM alarm
system”,then download and install this software.
35. Language Setting
In setup status, enter [65],then input [1~2], press [#]to confirm. Once the host makes a
“tick” sound, you will hear a voice prompt“setting completed”. Default language Chinese[2].
Operating method: [65] [ X] [ # ]
X indicates: Language
Example: English [1]
Operating:[65]
[1]
[#]
LCD display:
iPhone APP interface
-27-
Android APP interface
-28-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
App Use
In the state of factory defaults, user can control the panel remotely on the SMS interface of
the APP from any mobile phone. The panel only receive the APP command from the pr-set
numbers which have been stored in it.
(1)Add host account
(3)Delete Account
iOS mobile: Press [Edit], then press [Delete], the added host account will be deleted.
Android mobile: Press [Edit], long press the host account, then will come out the dialog
window of deleting account, press[Finish], the added account will be deleted.
(2)Main interface operation
Press the pr-set host account, enter into Main Menu,then user can operate the functions of
disarm,out arm, stay arm,dial back and monitor and so on.
Press the pr-set host account, enter "System Setting", then user can use app to remotely
setup the host parameter including "Host Alarm Phone Number Setting " (6 groups), "Host SMS
Number Setting”( 2 groups), “Naming Defense Zone", "Call Ringing Time", "Alarm Time Delay",
"Siren Ring Time Setting", "Host Timing Arm or Disarm Setting" and other operations.
Notes: For “Naming Defense Zone”,you can only change 2 zones. If naming in Chinese, the characters are
no more than 10. Naming in English, the characters are no more than 40. If operate by app,you must save
your phone number in host panel first or it will not work.
-29-
-30-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
Daily Operation
Operating: press [Out Arm
The Host Operating: [Out Arm
Remote controller is one kind of device which carries out mufti-function operation by radio.
Its function is convenient for user to control its state when he is at the door (outdoor) or longdistance, such as Out Arm, Stay Arm , Emergency Alarm , Disarm functions etc.
] of remote controller.
] (keypad lock is closed or [Out Arm
] + [user
password] + [#] (keypad lock is open) .
SMS operation: Edit SMS “1” and send it to the SIM number of host with your mobile
phone.
LCD display:
Out Arm key
Disarm key
Stay Arm key
Emergency Alarm key
Out Arm
Disarm
Press[
] key, host releases
Disarm: Press [
] key,host
prompt: “System armed”, Out
releases prompt: “System
Arm indicator LED on, all the
disarmed”, Disarm indicator
defense zones enter into Out
LED on, all the defense zones
Arm state.
enter into Disarm state.
2 . Stay Arm
It means, for the safety, while somebody is at home, you need to enable the peripheral: door,
window, balcony and boundary detectors of the alarm system while prevent from triggering the
indoor detectors, which may cause improper warning; then, you shall select Stay Arm, let just
part of the detectors work and disable the other parts.
Stay Arm
Remotes Operation: Just press [
Emergency Alarm
Stay Arm: press [
]key,
host releases prompt:“system
] once
SMS operation: Edit SMS “0” and send it to the SIM number of host with your mobile
phone.
Emergency Alarm: No matter
in which status, press the
armed”,Stay Arm indicator
LED on,all the defense zones
system will enter into alarm
enter into Stay Arm state.
state at once.
LCD display:
]key of remote controller,
1 . Out Arm
Out Arm means the host’s whole defense zones are in Arm state. In other words, when no
one in the house, all detectors would work and detect all deleting areas, when there are
detection sources(thieves invasion fire,gas leakage,etc.)trigger detector,the system makes
alarms immediately.
If the function of the keypad lock is closed, press the Out Arm [
], the host will go into Out
Arm state; If the function of the keypad lock is open, press the Out Arm[
]while this operation
need to input user’s password then to realize Out Arm.
-31-
-32-
GSM anti-theft alarm controller
GSM anti-theft alarm controller
3 . Disarm
5 . Remote Control by SMS
Disarm means to make the alarming host into non-alert state. One is, to Disarm the host from
Arm state; the other is, to stop the alarm when the host is making alarms. After disarming, even
if you trigger the detector, the host would not sound alarm (excluding 24- hour defense areas).
If keypad lock is closed, press [
]keypad directly to disarm. If keypad lock is open, press
], and follow voice prompt enter [user password, finally press [#] to confirm. [Out home] or
[Home] signal light is off. Disarming operation is completed.
Remotes Operation: Press [
Host Operation: Press[
]button.
]button
SMS operation: Edit SMS “2” and send it to the SIM number of host with your mobile phone.
LCD display:
To create SMS instructions to alarm host through the mobile phone, then to remote control the
host, make host enter into Arm or Disarm state; Also can open or close the Siren.
Detailed SMS instructions as follows:
Host Arm SMS instruction: Edit SMS “1” and send it to the SIM number of host with your
mobile phone, If you get back the message "Armed" from the
host which means the host has entered into Arm state.
Host Disarm SMS instruction: Edit SMS “2” and send it to the SIM number of host with
your mobile phone, If you get back the message "Disarmed"
from the host which means the host has entered into Disarm
state.
Open Siren SMS instruction: Edit SMS “6” and send it to the SIM number of host with
your mobile phone, If you get back the message "Siren On"
from the host which means the siren has sounded already.
Close Siren SMS instruction: Edit SMS “5” and send it to the SIM number of host with
your mobile phone, If you get back the message "Siren Off"
from the host which means the siren has been closed already.
6 . Remotely Control
The telephone (mobile) is connected to alarm host number, and after setting of ringing times,
the telephone receiver prompts computer-generated voice: “Please enter password”. The
password is entered via telephone (mobile). For wrong password, the host gives prompt:
“wrong password, please enter password again”. For correct password, the telephone receiver
4. Answer Alarm Call
When the host make alarms, siren releases voice prompt at once. First, it would send out
SMS, telling user which defense zone has alert, then it will dial the preset numbers to make
voice alarm. If no one answers the call, the system will call the next user number automatically.
The system will call each preset numbers for 3 times in order.
If you answer the call, you will hear the pre-record voice. You can set system to realize
various functions via your telephone or mobile phone keypad.
Hang up: If you hang-up directly without answering the call, system will call each preset
number circularly.
Press [*]: Play the recording.
Press [1]: The host stops alarming and to Arm; it stops calling users.
Press [2]: The host stops alarming and to Disarm; it stops calling users.
Press [3]: The host closes siren and monitors the scene for 30 seconds, for continuous
monitoring, press [3] again to monitor the abnormal sounds or a burglar intrusion
for another 30 seconds.
Press [4]: start talk-back 30s.
Note: Please press # to stop the calling of alarm.
-33-
prompts “press ① to arm, press ② to disarm, press ③ to monitor, press ④to talk ”. And after
getting access of remote control, phone button could be used for remote control.
Press [*]: play the recording.
Press [1]: the host stops alarm and enter into Arm state
Press [2]: the host stops alarm and enter into Disarm state
Press [3]: the host closes the siren, enter into monitoring state for 30 seconds and press
[3] for another 30 seconds to monitor the abnormal sounds or a burglar
intrusion in case of continuous monitoring.
Press [4]: start talk-back 30s.
Notes: Please press “ #” to stop the calling of alarm.
7 . SOS
Some special cases occur in the family: sudden illness for the elderly or children results in
first aid; in case of sudden fire, help is needed; in case of housebreaking, the alarm is required;
So please just press the host keypad “Emergency Alarm[SOS]” ,remote controller key [ SOS ].
Alarm system will immediately sound loudly and automatically call the pre-set phone number.
Remotes operation: press [SOS]button
Host operation: press [SOS] button on keypad
-34-
GSM anti-theft alarm controller
Maintenance
1.System detection
GSM anti-theft alarm controller
Technical Parameters 1、2
Appendix 1
Although the alarm system is used every day, it still needs regular care and maintenance and
detection to ensure that the alarm system will be stable, reliable and safe. Normally the host
needs a thorough inspection every 3 months and the detectors need to be checked once a
month, at least once every 3 months in case of bad conditions.
2. Host detection
(1) Whether the host normally performs Arm or Disarm.
(2) Whether the host normally dials up the telephone numbers.
Input power:
Standby current :
Alarm current
Wireless frequency
Encoded mode
GSM
DC12V/1A
<60mA
<450mA
433MHz/315MHz
1527/330K
850/900/1800/1900MHz
(3) Whether the detector signal is received or backup battery works
Backup battery
3.Sensor detection
Siren volume
Li AAA*6 DC7.4V
110dB
(1) Manually trigger the detector to check whether it make alarms as usual.
(2) Check batteries of all detectors to check whether it is under-voltage.
(3) Check whether wireless detector is communicated with the host during emission testing
4.Notice
(1) Do not dismantle, repair and modify products privately, or accidents and failures may be
caused.
(2) Do not drop the product on the ground or hard objects to avoid strong impact with failure or
Appendix 2
Defense zone
Arm
Home
Type
Siren
1 defense zone
effective
effective
24H
Yes
02-99 defense zone
effective
effective
Real-time
Yes
SOS
effective
effective
24H
Yes
Wired defense zone
effective
ineffective
Real-time
Yes
damage.
(3) Without permit and consent from relevant department, do not directly set "110", "119" or
alarm phone number of police station as alarm phone number of the host.
-35-
Administrator password
6666
Remote control
On
User password
1234
Siren
Off
Siren sound time
According setting time
Home appliance
Optional
-36-
Wireless intelligent security alarm system
GSM anti-theft alarm controller
Technical Parameters 3
Appendix 3 :Administrator password system setup command table
No
Setting item
Address
Data(XY)
Remark
Appendix 3 :Administrator password system setup command table
Factor y
Default
Coding of Remote Controller
Setting
Address
Data(XY)
Remark
Factor y
Default
ON
OFF
Coding of Wireless Detector
Setting
99
Single Wireless Detector
Deleting Setting
99
Host Timing Arm /
Disarm Setting
All Wireless Detectors
Deleting Setting
XXXX= arm time
YYYY= disarm time
Host Reset Setting
Host Logs Inquires
99
Host Logs Deleting Setting
Wired Alarm Type Setting
-37-
Setting item
Host Timing Function Setting
All Remote Controller
Deleting Setting
Wireless Alarm Type Setting
No
Wireless Siren Coding Setting
XXXXXXXX=8-digit
wireless siren coding
Wireless Switch Coding
Setting
XXXXXXXX=8-digit
wireless switch coding
Remotes Operation Voice
Prompt Setting
X=1 On ,X=0 Off
Siren Ring Time Setting
X=00~15 minutes
Arm Time Delay Setting
X=00~99 seconds
SMS Notification of Arm/
Disarm Setting
X=1 send SMS
X=0 don't send SMS
System Clock Setting
XXX=year, month,day,
YY= hour, minute
3 minutes
SMS Phone Number Setting
X= SMS number
0 second
Alarm Phone Number Setting
X=alarm number
Host GSM Signal Checking
Setting
Defense Zone Alarm Time
Delay Setting
X=02~99 defense zone
Y=00~99 seconds
0 second
Telephone Dial-up Cycle
Times Setting
X=00~09 times
Remote Call Ring Times
Setting
X=0~9 times
Recording Setting
X=#, play automatically after
recording
Change User Password
Setting
XXXX= 4-digit
Change Administrator
Password Setting
XXXX= 4-digit
Host Keypad Lock Setting
X=1 ON, X=0 OFF
Don't send
SMS
LCD Backlight Time Setting
XX=00~99 seconds
9 times
Sound Volume Setting
X=0~9 level
6 times
Language Setting
X=1~2
1 English, 2 Chinese
-38-
Any changes or modifications not expressly approved by the
party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment generates, uses and can radiate radio
frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from
that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, This
equipment should be installed and operated with minimum distance
between 20cm the radiator your body: Use only the supplied antenna.
FCC ID: 2AIT9-PG101

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Creator                         : Administrator
Title                           : PG-101英文说明书-公司标准版V1.1 20170223.cdr
Creation Date--Text             : 
Mod Date--Text                  : 
Producer                        : Corel PDF Engine Version 14.0.0.653
Creator Tool                    : CorelDRAW
Modify Date                     : 2017:03:08 10:41:59+08:00
Metadata Date                   : 2017:03:08 10:41:59+08:00
Document ID                     : uuid:23755bb9-cb85-421e-8fb1-d99ddc17b8f5
Instance ID                     : uuid:5f9caa79-ed21-445d-8c93-aaae3df0d7c9
Page Count                      : 22
Author                          : Administrator
Create Date                     : D:20170303030719Z
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AIT9-PG101

Navigation menu