Manual No.TDR-MNL-C302-EN-100    TAKAYA RFID TR3 Series  Introduction  Thank you for purchasing a TR3-C302 RFID READER/WRITER.  Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference.
Manual No.TDR-MNL-C302-EN-100    TAKAYA RFID TR3 Series  Regulations and Standards  FCC  This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart C of the FCC Rules.  FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.  FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  The following sentence has to be displayed on the outside of the device in which the transmitter module is installed : “Contains FCC ID: ****************”   Japan Radio Law  Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment;   Standard: ARIB STD-T82 Tags  This product can communicate the standard tags of ISO/IEC15693 and ISO/IEC18000-3(Mode1,3), ISO/IEC14443A, ISO/IEC14443B, ISO/IEC 18092(212kbps Passive Mode, FeliCa). Supports Manufacturer Tag-it HF-I Texas Instruments my-d Infineon Technologies I・CODE SLI, Mifare Ultralight NXP Semiconductors MB89R118 FUJITSU Japan Felica Sony Corporation   RoHS is support  Restriction of Hazardous Substances Waste  Dispose of the Products as industrial waste.
Manual No.TDR-MNL-C302-EN-100    TAKAYA RFID TR3 Series  Safety Precautions  The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions.    The following signal words are used in this manual.  Failure to comply with a WARNING may result in serious injury or death.  Failure  to  comply  with  a  CAUTION  may  result  in  injury  to  the operator, or damage to the items involved.       Be sure to observe the following precautions to ensure safe use of the Products.  Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the possibility of fire or electric shock injuries. This product is using the RFID reader writer radio equipment. Therefore, depending on where the applications you use may affect medical equipment. To minimize the impact of medical equipment for use, please observe the following countermeasure. The Japan Automatic Identification Systems Association (JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment.          Be sure to observe the following precautions to ensure safe use of the Products.  Installation and storage environment 1. Do not use the Products in sunlight. 2. Do not use the Products in environment of spray of water, oil or chemicals. 3. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 4. Do not use the Products in environment of hot humid. 5. Do not use the Products in environment of vibration or shock. 6. Do not use the Products in environment of condensation. 7. Do not use the Products in environment of around the metal is covered. 8. Do not use the Products in environment of high temperature. 9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage. 10. Do not use the Products in unstable place. 11. If there is failure, discontinue use immediately, please contact us or the distributor. Installation 1. Turn off the power before installation or removing. 2. The following effects may not work correctly.   ・  Near 13.56MHz radio device   ・  Near speakers , Inverter, motor and Plasma Display 3. The communication range may vary due to environment and conditions.   ← RFID Sticker
Manual No.TDR-MNL-C302-EN-100    TAKAYA RFID TR3 Series  Contents 1 Product Overview ...................................................................................................... 1 1.1 Features .............................................................................................................................................. 1 2 Names of Parts and Functions ..................................................................................... 2 2.1 TR3-C302 ............................................................................................................................................ 2 2.2 Antenna .............................................................................................................................................. 3 2.2.1 TR3-A202 ........................................................................................................................................ 3 2.2.2 TR3-A302 ........................................................................................................................................ 4 2.2.3 TR3-A401 ........................................................................................................................................ 4 3 Installation and connection ......................................................................................... 5 3.1 Installation into a host device .............................................................................................................. 5 3.2 Antenna installation into a host device ................................................................................................. 6 3.2.1 Screw holes ...................................................................................................................................... 6 3.2.2 Guide ............................................................................................................................................... 6 3.3 Connection .......................................................................................................................................... 7 3.3.1 Attaching the Cable and Antenna ........................................................................................................ 7 3.3.2 Direct connection to the Host Device Interface .................................................................................... 7 3.3.3 Using the interface board to connect to the Host Device Interface .......................................................... 8 4 Specifications ............................................................................................................. 9 4.1 TR3-C302 ............................................................................................................................................ 9 4.2 Antenna ............................................................................................................................................ 14 4.2.1 TR3-A202 ...................................................................................................................................... 14 4.2.2 TR3-A302 ...................................................................................................................................... 15 4.2.3 TR3-A401 ...................................................................................................................................... 16 4.3 Cable ................................................................................................................................................. 17 4.3.1 TR3-AC-1A-*** ............................................................................................................................. 17 4.3.2 TR3-AC-2A-*** ............................................................................................................................. 17 5 Maintenance ............................................................................................................ 18 Revision History ............................................................................................................. 19
Manual No.TDR-MNL-C302-EN-100 1  Product Overview 1.1  Features      TAKAYA RFID TR3 Series  1 Product Overview    1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.                           ■ Conform to international standards ISO/IEC15693 and ISO/IEC18000-3(Mode1, 3) , ISO/IEC14443A, ISO/IEC14443B,   ISO/IEC 18092(212kbps Passive Mode, FeliCa) is supports.  ■ Rich Products  Various interface RS-232C, USB, TCP/IP.  Antennas of various sizes  ■ Software  TR3-series common communication protocol  Software Development Kit  ■ Useful  Continuous inventory mode UID of the tag automatically sends Host Device.  RDLoop mode UID or User Data of the tag automatically sends Host Device.     For more information please refer to the TR3-PROTOCOL manual.  ■ Environmentally EU RoHS(2002/95/EC) Support  Antenna CPU Memory RF-ASIC READER/WRITER Load Settings Save Settings Interface Tags   Host Device Interface RS-232C、LAN(TCP/IP)、USB Communications UART(CMOS Level)
Manual No.TDR-MNL-C302-EN-100 2  Names of Parts and Functions 2.1  TR3-C302      TAKAYA RFID TR3 Series  2 Names of Parts and Functions    2.1 TR3-C302                      No Name Description ① CN1 This connector is for connection to the host. ② CN2 Connect the antenna cable. ③ CN3 Connect the buzzer control cable. ④ LED1 Displays the status of this product. ⑤ Inspection mark  ⑥ Nameplate Production numbers, will be 8-digit serial number.      ⑦ Screw holes M3 holes  ⑦ ④ ①   ③ ② ⑥ ⑤ Model Name Serial number:********(F)
Manual No.TDR-MNL-C302-EN-100 2  Names of Parts and Functions 2.2  Antenna      TAKAYA RFID TR3 Series  2.2 Antenna 2.2.1 TR3-A202                      No Name Description ① CN1 Connect the antenna cable. ② Nameplate Production numbers, will be 8-digit serial number.     ③ Inspection mark  ④ Screw holes M3 holes  ④ ① ② ③ Model Name Serial number:********(F)
Manual No.TDR-MNL-C302-EN-100 2  Names of Parts and Functions 2.2  Antenna      TAKAYA RFID TR3 Series  2.2.2 TR3-A302                   No Name Description ① Inspection mark  ② Screw holes M3 holes ③ Nameplate Production numbers, will be 8-digit serial number.     ④ CN1 Connect the antenna cable.    2.2.3 TR3-A401             No Name Description ① CN1 Connect the antenna cable. ② Nameplate Production numbers, will be 8-digit serial number.     ③ Inspection mark    ② ③ ④ ① Model Name Serial number:********(F) ① ② ③ Model Name Serial number:********(F)
Manual No.TDR-MNL-C302-EN-100 3  Installation and connection 3.1  Installation into a host device      TAKAYA RFID TR3 Series  3 Installation and connection   3.1 Installation into a host device                         Four, M3 holes
Manual No.TDR-MNL-C302-EN-100 3  Installation and connection 3.2  Antenna installation into a host device      TAKAYA RFID TR3 Series  3.2 Antenna installation into a host device  3.2.1 Screw holes                     3.2.2 Guide TR3-A401 is recommended that you set up a guide on fixed-like the figure below.                TR3-A401 M3 Screw Host Device
Manual No.TDR-MNL-C302-EN-100 3  Installation and connection 3.3  Connection      TAKAYA RFID TR3 Series  3.3 Connection This product will connect with the antenna and antenna cables.   This product connects with Host Device that direct connection or connect using our interface.  3.3.1 Attaching the Cable and Antenna                   3.3.2 Direct connection to the Host Device Interface      Please prepare to the interface harness.                      Host Device Host Device Interface harness TR3-C302  TR3-C302 Antenna Antenna Cable Host Device Interface
Manual No.TDR-MNL-C302-EN-100 3  Installation and connection 3.3  Connection      TAKAYA RFID TR3 Series Host Device  3.3.3 Using the interface board to connect to the Host Device Interface    Interface board, please contact us.                                    TR3-C302  Interface Cable Interface board Interface harness Host Device Interface
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.1  TR3-C302      TAKAYA RFID TR3 Series  4 Specifications    4.1 TR3-C302 ■ Specifications Specifications Item Parameter Applicable Standards Japan Radio Law ARIB STD-T82 RoHS EU RoHS(2002/95/EC) Supports Radio Frequency Carrier frequency 13.56MHz ±50ppm(Ta=25℃) or less Transmit  power  or power range 200mW ± 20%(Ta=25℃, VCC=5.0V) Standards ISO/IEC 15693、ISO/IEC18000-3(Mode1) ISO/IEC 14443A、ISO/IEC 14443B、ISO/IEC 18092(FeliCa) Tags Tag-it HF-I, my-d, I・CODE SLI, MB89R118 Mifare Ultralight, FeliCa (※1) Data rate ・ISO/IEC 15693,ISO/IEC18000-3(Mode1)  Speed Data rate Product⇒Tag 1/4 26.48kbps 1/256 1.65kbps Tag⇒Product 26.69kbps ・ISO/IEC18000-3(Mode3)    Parameter Product⇒Tag 26.7kbps~100kbps Tag⇒Product 53kbps ・ISO/IEC 14443A, ISO/IEC 14443B    106 kbps ・ISO/IEC 18092(Passive Mode)  212kbps Modulation ・ISO/IEC 15693,ISO/IEC18000-3(Mode1)  Parameter Product⇒Tag ASK 10% / ASK 100% Tag⇒Product ASK   ・ISO/IEC18000-3(Mode3)  Parameter Product⇒Tag ASK 10% Tag⇒Product ASK ・ISO/IEC 14443A  Parameter Product⇒Tag ASK 100% Tag⇒Product ASK ・ISO/IEC 14443B  Parameter Product⇒Tag ASK 10% Tag⇒Product ASK ・ISO/IEC 18092(Passive Mode)  Parameter Product⇒Tag ASK 10%  Anti-collision Support   ※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated.          my-d is a registered trademark of Infineon Technologies AG.          I・CODE SLI, Mifare Ultralight are registered trademarks of NXP Semiconductors.                   MB89R118 is a registered trademark of FUJITSU Japan.                   Felica is a registered trademark of Sony Corpration.
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.1  TR3-C302      TAKAYA RFID TR3 Series  Specifications Item Parameter Controll Command Please refer to the TR3-Protocol-Manual. Host Interface UART(CMOS) Item Parameter Speed 9600bps 19200bps(※2) 38400bps Data bits 8 Parity None Stop bit 1 Flow control None   LED1 1pc (3 colors, red/green/orange) Connector CN1 Connector : JST S10B-PH-SM4-TB(LF)(SN) Housing : JST PHR-10 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No. Symbol Function 1 VCC Power 2 VCC Power 3 GND GND 4 GND GND 5 Rx Received data signal 6 Tx Transmitted data signal 7 VCC2 Power output 8 IO1 Input/Output  or  Detection  signal output H : Detection 9 IO2 Input/Output or Trigger input L : Trigger ON 10 IO3 Input/Output   CN2 Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No. Symbol Function 1 RF Analog signal 2 GND GND    ※2:initialization
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.1  TR3-C302      TAKAYA RFID TR3 Series  Specifications Item Parameter Mechanical data Dimensions (W x D x H) 40 x 60 x 7.1mm Weight approx. 12g Installation M3 Screw   Screw is not included. Electrical data Power Supply Voltage :DC+5.0V ±10% Current consumption :approx. 160mA Carrier off :approx. 35mA   Power down mode :approx. 24mA   Consumption :max 1.0W    Ambient Conditions Temperature Operating range 0 to 55 degree Humidity  Operating range 30 to 80%RH Temperature Storage range 0 to 55 degree Humidity Storage range 30 to 80%RH Other Accessories None
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.1  TR3-C302      TAKAYA RFID TR3 Series  ■ Dimensions                                                        Unit:mm Tolerance:±1mm ( )is Recommended Dimension Screw hole depth:3mm
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.1  TR3-C302      TAKAYA RFID TR3 Series  ■ Connections Names Model Notes Antenna TR3-A202  TR3-A302 TR3-A401 Cable TR3-AC-1A-*** *** puts the cable length. 9cm ~ 50cm cable are available. TR3-AC-2A-*** *** puts the cable length. 10cm ~ 3m cable are available. Interface board TR3-IF-1C RS232C interface TR3-IF-N1 TCP/IP interface TR3-IF-U1 TR3-IF-U1A USB interface  ■ Electrical Characteristics(CN1)  VDD=5V Item Condition MIN TYP MAX Unit H input voltage RX,IO1,IO2,IO3 2.5  5.0 V L input voltage RX,IO1,IO2,IO3 0  1.0 V H output voltage IOH=-5mA,-20mA 3.0   V L output voltage IOL=5mA,20mA   2.0 V Pull-up resistor  25.0 50.0 100.0 kΩ ・TX, RX, IO1, IO2 and IO3 is, Pull-up resistor has been connected. ・TX, RX, IO1, IO2 and IO3 is, 100 ohm resistor has been connected.     Output port, LED is not driven. If the LED drive, please use the digital transistors.
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.2  Antenna      TAKAYA RFID TR3 Series  4.2 Antenna 4.2.1 TR3-A202 ■ Specifications Specifications Item Parameter Applicable Standards RoHS EU RoHS(2002/95/EC) Support Antenna Resonant frequency 13.56MHz ±40kHz(Ta=25℃) Communication distance Max 10cm (Communication distance depends on the environment.) Connector CN1 Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No. Symbol Function 1 RF Analog signal 2 GND GND    Mechanical data Dimensions (W x D x H) 60 x 65 x 9.1 mm Weight approx. 11g Installation M3 Screw   Screw is not included. Ambient Conditions Temperature Operating range 0 to 55 degree Humidity Operating range 30 to 80%RH Temperature Storage range 0 to 55 degree Humidity Storage range 30 to 80%RH Other Accessories RFID Sticker 1 sheet   Model Name : SEL41400L  ■ Dimensions   Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.2  Antenna      TAKAYA RFID TR3 Series  4.2.2 TR3-A302 ■ Specifications Specifications Item Parameter Applicable Standards RoHS EU RoHS(2002/95/EC) Support Antenna Resonant frequency 13.56MHz ±40kHz(Ta=25℃) Communication distance Max 7cm (Communication distance depends on the environment.) Connector CN1 Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No. Symbol Function 1 RF Analog signal 2 GND GND    Mechanical data Dimensions (W x D x H) 15 x 52.5 x 9.1 mm Weight approx. 3g Installation M3 Screw   Screw is not included. Ambient Conditions Temperature Operating range 0 to 55 degree Humidity Operating range 30 to 80%RH Temperature Storage range 0 to 55 degree Humidity Storage range 30 to 80%RH Other Accessories RFID Sticker 1 sheet   Model Name : SEL41400L  ■ Dimensions                    Unit:mm Tolerance:±1mm Substrate thickness : 1.6mm
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.2  Antenna      TAKAYA RFID TR3 Series  4.2.3 TR3-A401 ■ Specifications Specifications Item Parameter Applicable Standards RoHS EU RoHS(2002/95/EC) Support Antenna Resonant frequency 13.56MHz ±40kHz(Ta=25℃) Communication distance Max 5cm (Communication distance depends on the environment.) Connector CN1 Connector : JST S2B-PH-K-S(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S  Pin assignment Pin No. Symbol Function 1 RF Analog signal 2 GND GND    Mechanical data Dimensions (W x D x H) 15 x 30 x 9.1 mm Weight approx. 2g Installation M3 Screw   Screw is not included. Ambient Conditions Temperature Operating range 0 to 55 degree Humidity Operating range 30 to 80%RH Temperature Storage range 0 to 55 degree Humidity Storage range 30 to 80%RH Other Accessories RFID Sticker 1 sheet   Model Name : SEL41400L  ■ Dimensions                      Unit:mm Tolerance:±1mm Substrate thickness : 1.0mm
Manual No.TDR-MNL-C302-EN-100 4  Specifications 4.3  Cable      TAKAYA RFID TR3 Series  4.3 Cable  4.3.1 TR3-AC-1A-***  ■ Model Name      ■ Specifications Item Parameter RoHS EU RoHS(2002/95/EC) Support Linetype Twisted pair cable Connector PH-PH Cable loss 9cm : approx. 0.061dB 50cm : approx. 0.337dB  ■ Dimensions             4.3.2 TR3-AC-2A-***  ■ Model Name      ■ Specifications Item Parameter RoHS EU RoHS(2002/95/EC) Support Linetype Coaxial cable 1.5D-2V Connector PH-PH Cable loss 10cm : approx. 0.043dB 3m    : approx. 0.255dB  ■ Dimensions            ( )is Recommended Dimension (Cable length)  TR3-AC-2A-*** Enter the cable length(Unit:mm) 100~3M ( )is Recommended Dimension (Cable length)  TR3-AC-1A-*** Enter the cable length(Unit:mm) 090~500
Manual No.TDR-MNL-C302-EN-100       TAKAYA RFID TR3 Series  5 Maintenance    This product is mainly used in electronic components and semiconductors.   Therefore, the long-term stable operation, the environment and  conditions  are  expected to  defect, as shown below.  • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases.   In order to use this product at its best, please conduct routine or periodic inspections. Item Maintenance Criteria Ambient conditions Temperature Temperature Operating range 0 to 55 degree Humidity Humidity Operating range 30 to 80%RH Enclosure rating Check the dusty None Corrosive Check the corrosion None Power Input Check the voltage Input Voltage : DC5V±10% Voltage fluctuation Check the Voltage fluctuation Attachment Product Check the Screw Checking and verifying Check the Connector Cable Check the Cable break None Performance Check the Performance Work
Manual No.TDR-MNL-C302-EN-100       TAKAYA RFID TR3 Series  Revision History  Revision code Date Revised contents 1.00 2014/11/05 Original production
 20                                                        [URL] http://www.takaya.co.jp/ [Mail] rfid@takaya.co.jp

Navigation menu