User’s Manual
TR3-C302
Manual No.TDR-MNL-C302-EN-100
Introduction
Thank you for purchasing a TR3-C302 RFID READER/WRITER.
Be sure to read this manual before using the product.
After reading it, store the manual in a convenient place for future reference.
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
Regulations and Standards
FCC
This product is conform to the FCC standards.
FCC Rules (Federal Communications Commission)
This product complies with Part 15 Subpart C of the FCC Rules.
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
The following sentence has to be displayed on the outside of the device in which the transmitter module
is installed : “Contains FCC ID: ****************”
Japan Radio Law
Equipment using high frequencies: Inductive Reading/Writing Communications Equipment
Conforming standards: Inductive Reading/Writing Communications Equipment;
Standard: ARIB STD-T82
Tags
This product can communicate the standard tags of ISO/IEC15693 and ISO/IEC18000-3(Mode1,3),
ISO/IEC14443A, ISO/IEC14443B, ISO/IEC 18092(212kbps Passive Mode, FeliCa).
Supports
Manufacturer
Tag-it HF-I
Texas Instruments
my-d
Infineon Technologies
I・CODE SLI, Mifare Ultralight NXP Semiconductors
MB89R118
FUJITSU Japan
Felica
Sony Corporation
RoHS is support
Restriction of Hazardous Substances
Waste
Dispose of the Products as industrial waste.
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
Safety Precautions
The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of
this product. The precautions provided here contain important safety information. Be sure to observe these
precautions.
The following signal words are used in this manual.
Failure to comply with a WARNING may result in serious injury or
death.
Failure to comply with a CAUTION may result in injury to the
operator, or damage to the items involved.
Be sure to observe the following precautions to ensure safe use of the Products.
Decomposition of this product and cable, repair, remodeling, please strictly prohibited. There is the
possibility of fire or electric shock injuries.
This product is using the RFID reader writer radio equipment. Therefore, depending on where the
applications you use may affect medical equipment. To minimize the impact of medical equipment for use,
please observe the following countermeasure. The Japan Automatic Identification Systems Association
(JAISA) guidelines are as follows: RFID antennas from implanted cardiac pacemakers or other medical
devices please 22cm apart. We recommend that you paste "RFID sticker" at equipment.
← RFID Sticker
Be sure to observe the following precautions to ensure safe use of the Products.
Installation and storage environment
1. Do not use the Products in sunlight.
2. Do not use the Products in environment of spray of water, oil or chemicals.
3. Do not use the Products in environments with flammable, explosive, or corrosive gasses.
4. Do not use the Products in environment of hot humid.
5. Do not use the Products in environment of vibration or shock.
6. Do not use the Products in environment of condensation.
7. Do not use the Products in environment of around the metal is covered.
8. Do not use the Products in environment of high temperature.
9. Do not use the Products in environment that has a device that generates magnetic field and shock voltage.
10. Do not use the Products in unstable place.
11. If there is failure, discontinue use immediately, please contact us or the distributor.
Installation
1. Turn off the power before installation or removing.
2. The following effects may not work correctly.
・ Near 13.56MHz radio device
・ Near speakers , Inverter, motor and Plasma Display
3. The communication range may vary due to environment and conditions.
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
Contents
Product Overview ...................................................................................................... 1
1.1
Features .............................................................................................................................................. 1
Names of Parts and Functions ..................................................................................... 2
2.1
TR3-C302 ............................................................................................................................................ 2
2.2
Antenna .............................................................................................................................................. 3
2.2.1 TR3-A202 ........................................................................................................................................ 3
2.2.2 TR3-A302 ........................................................................................................................................ 4
2.2.3 TR3-A401 ........................................................................................................................................ 4
Installation and connection ......................................................................................... 5
3.1
Installation into a host device .............................................................................................................. 5
3.2
Antenna installation into a host device ................................................................................................. 6
3.2.1 Screw holes ...................................................................................................................................... 6
3.2.2 Guide ............................................................................................................................................... 6
3.3
Connection .......................................................................................................................................... 7
3.3.1 Attaching the Cable and Antenna ........................................................................................................ 7
3.3.2 Direct connection to the Host Device Interface .................................................................................... 7
3.3.3 Using the interface board to connect to the Host Device Interface .......................................................... 8
Specifications ............................................................................................................. 9
4.1
TR3-C302 ............................................................................................................................................ 9
4.2
Antenna ............................................................................................................................................ 14
4.2.1 TR3-A202 ...................................................................................................................................... 14
4.2.2 TR3-A302 ...................................................................................................................................... 15
4.2.3 TR3-A401 ...................................................................................................................................... 16
4.3
Cable ................................................................................................................................................. 17
4.3.1 TR3-AC-1A-*** ............................................................................................................................. 17
4.3.2 TR3-AC-2A-*** ............................................................................................................................. 17
Maintenance ............................................................................................................ 18
Revision History ............................................................................................................. 19
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
1
Product Overview
1.1 Features
1 Product Overview
1.1 Features
This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact
IC can read and write RFID tag data.
This Product is designed to be embedded and integrated within OEM devices and finished products such as label
printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.
Host Device Interface
RS-232C、LAN(TCP/IP)、USB
Interface
UART(CMOS Level)
READER/WRITER
Load Settings
CPU
Memory
Save Settings
RF-ASIC
Communications
Antenna
Tags
■ Conform to international standards
ISO/IEC15693 and ISO/IEC18000-3(Mode1, 3) , ISO/IEC14443A, ISO/IEC14443B,
ISO/IEC 18092(212kbps Passive Mode, FeliCa) is supports.
■ Rich Products
 Various interface RS-232C, USB, TCP/IP.
 Antennas of various sizes
■ Software
 TR3-series common communication protocol
 Software Development Kit
■ Useful
 Continuous inventory mode
UID of the tag automatically sends Host Device.
 RDLoop mode
UID or User Data of the tag automatically sends Host Device.
For more information please refer to the TR3-PROTOCOL manual.
■ Environmentally
EU RoHS(2002/95/EC) Support
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.1 TR3-C302
2 Names of Parts and Functions
2.1 TR3-C302
⑦
④
⑤
①
②
③
No
①
②
③
④
⑤
⑥
Name
CN1
CN2
CN3
LED1
Inspection mark
Nameplate
⑥
Description
This connector is for connection to the host.
Connect the antenna cable.
Connect the buzzer control cable.
Displays the status of this product.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********(F)
⑦
Screw holes
Manual No.TDR-MNL-C302-EN-100
M3 holes
TAKAYA RFID TR3 Series
2
Names of Parts and Functions
2.2 Antenna
2.2 Antenna
2.2.1
TR3-A202
①
②
③
④
No
①
②
Name
CN1
Nameplate
Description
Connect the antenna cable.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********(F)
③
④
Inspection mark
Screw holes
Manual No.TDR-MNL-C302-EN-100
M3 holes
TAKAYA RFID TR3 Series
2
2.2.2
Names of Parts and Functions
2.2 Antenna
TR3-A302
①
②
③
No
①
②
③
Name
Inspection mark
Screw holes
Nameplate
④
Description
M3 holes
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********(F)
④
2.2.3
CN1
TR3-A401
①
No
①
②
Connect the antenna cable.
②
Name
CN1
Nameplate
③
Description
Connect the antenna cable.
Production numbers, will be 8-digit serial number.
Model Name
Serial number:********(F)
③
Inspection mark
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
3.1
3 Installation and connection
Installation into a host device
3 Installation and connection
3.1 Installation into a host device
Four, M3 holes
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
3.2
3 Installation and connection
Antenna installation into a host device
3.2 Antenna installation into a host device
3.2.1
Screw holes
M3 Screw
3.2.2
Guide
TR3-A401 is recommended that you set up a guide on fixed-like the figure below.
Host Device
TR3-A401
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
3
Installation and connection
3.3 Connection
3.3 Connection
This product will connect with the antenna and antenna cables.
This product connects with Host Device that direct connection or connect using our interface.
3.3.1
Attaching the Cable and Antenna
Host Device
TR3-C302
Antenna
Antenna Cable
3.3.2
Direct connection to the Host Device Interface
Please prepare to the interface harness.
Host Device
TR3-C302
Host Device
Interface
Interface harness
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
3
3.3.3
Installation and connection
3.3 Connection
Using the interface board to connect to the Host Device Interface
Interface board, please contact us.
Host Device
TR3-C302
Interface Cable
Host Device
Interface
Interface board
Interface harness
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
Specifications
4.1 TR3-C302
4 Specifications
4.1 TR3-C302
■ Specifications
Specifications
Item
Parameter
Applicable
Japan Radio Law
ARIB STD-T82
Standards
RoHS
EU RoHS(2002/95/EC) Supports
Radio
Carrier frequency
13.56MHz ±50ppm(Ta=25℃) or less
Frequency
Transmit power or 200mW ± 20%(Ta=25℃, VCC=5.0V)
power range
Standards
ISO/IEC 15693、ISO/IEC18000-3(Mode1)
ISO/IEC 14443A、ISO/IEC 14443B、ISO/IEC 18092(FeliCa)
Tags
Tag-it HF-I, my-d, I・CODE SLI, MB89R118
Mifare Ultralight, FeliCa (※1)
Data rate
・ISO/IEC 15693,ISO/IEC18000-3(Mode1)
Speed
Data rate
1/4
26.48kbps
Product⇒Tag
1/256
1.65kbps
26.69kbps
Tag⇒Product
・ISO/IEC18000-3(Mode3)
Parameter
Product⇒Tag
26.7kbps~100kbps
53kbps
Tag⇒Product
・ISO/IEC 14443A, ISO/IEC 14443B 106 kbps
・ISO/IEC 18092(Passive Mode) 212kbps
Modulation
・ISO/IEC 15693,ISO/IEC18000-3(Mode1)
Parameter
ASK 10% / ASK 100%
Product⇒Tag
ASK
Tag⇒Product
・ISO/IEC18000-3(Mode3)
Parameter
ASK 10%
Product⇒Tag
ASK
Tag⇒Product
・ISO/IEC 14443A
Parameter
ASK 100%
Product⇒Tag
ASK
Tag⇒Product
・ISO/IEC 14443B
Parameter
ASK 10%
Product⇒Tag
ASK
Tag⇒Product
・ISO/IEC 18092(Passive Mode)
Parameter
ASK 10%
Product⇒Tag
Anti-collision
Support
※1:Tag-it HF-I is a registered trademark of Texas Instruments Incorporated.
my-d is a registered trademark of Infineon Technologies AG.
I・CODE SLI, Mifare Ultralight are registered trademarks of NXP Semiconductors.
MB89R118 is a registered trademark of FUJITSU Japan.
Felica is a registered trademark of Sony Corpration.
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
Specifications
Item
Controll
Command
Host Interface
Connector
LED1
CN1
Parameter
Please refer to the TR3-Protocol-Manual.
UART(CMOS)
Item
Parameter
Speed
9600bps
19200bps(※2)
38400bps
Data bits
Parity
None
Stop bit
Flow control
None
1pc (3 colors, red/green/orange)
Connector : JST S10B-PH-SM4-TB(LF)(SN)
Housing : JST PHR-10
Contact : JST SPH-002T-P0.5S
Pin assignment
Pin No.
CN2
Specifications
4.1 TR3-C302
Symbol
VCC
VCC
GND
GND
Rx
Tx
VCC2
IO1
IO2
10
IO3
Function
Power
Power
GND
GND
Received data signal
Transmitted data signal
Power output
Input/Output or Detection signal
output H : Detection
Input/Output or Trigger input
L : Trigger ON
Input/Output
Connector : JST S2B-PH-SM4-TB(LF)(SN)
Housing : JST PHR-2
Contact : JST SPH-002T-P0.5S
Pin assignment
Pin No.
Symbol
RF
GND
Function
Analog signal
GND
※2:initialization
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
Specifications
Item
Mechanical
Dimensions
data
(W x D x H)
Weight
Installation
Electrical
data
Power
Ambient
Conditions
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Other
Manual No.TDR-MNL-C302-EN-100
Specifications
4.1 TR3-C302
Parameter
40 x 60 x 7.1mm
approx. 12g
M3 Screw
Screw is not included.
Supply Voltage
Current consumption
Carrier off
Power down mode
Consumption
0 to 55 degree
:DC+5.0V ±10%
:approx. 160mA
:approx. 35mA
:approx. 24mA
:max 1.0W
30 to 80%RH
0 to 55 degree
30 to 80%RH
None
TAKAYA RFID TR3 Series
4
Specifications
4.1 TR3-C302
■ Dimensions
Unit:mm
Tolerance:±1mm
( )is Recommended Dimension
Screw hole depth:3mm
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
■ Connections
Names
Antenna
Cable
Model
TR3-A202
TR3-A302
TR3-A401
TR3-AC-1A-***
TR3-AC-2A-***
Interface board
TR3-IF-1C
TR3-IF-N1
TR3-IF-U1
TR3-IF-U1A
Specifications
4.1 TR3-C302
Notes
*** puts the cable length.
9cm ~ 50cm cable are available.
*** puts the cable length.
10cm ~ 3m cable are available.
RS232C interface
TCP/IP interface
USB interface
■ Electrical Characteristics(CN1)
VDD=5V
Item
Condition
MIN
TYP
H input voltage
RX,IO1,IO2,IO3
2.5
L input voltage
RX,IO1,IO2,IO3
H output voltage
IOH=-5mA,-20mA
3.0
L output voltage
IOL=5mA,20mA
Pull-up resistor
25.0
50.0
・TX, RX, IO1, IO2 and IO3 is, Pull-up resistor has been connected.
・TX, RX, IO1, IO2 and IO3 is, 100 ohm resistor has been connected.
Output port, LED is not driven. If the LED drive, please use the digital transistors.
Manual No.TDR-MNL-C302-EN-100
MAX
5.0
1.0
2.0
100.0
Unit
kΩ
TAKAYA RFID TR3 Series
4
Specifications
4.2 Antenna
4.2 Antenna
4.2.1
TR3-A202
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Communication
distance
Connector
CN1
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz ±40kHz(Ta=25℃)
Max 10cm
(Communication distance depends on the environment.)
Connector : JST S2B-PH-SM4-TB(LF)(SN)
Housing : JST PHR-2
Contact : JST SPH-002T-P0.5S
Pin assignment
Pin No.
Mechanical
data
Ambient
Conditions
Other
Dimensions
(W x D x H)
Weight
Installation
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Symbol
RF
GND
Function
Analog signal
GND
60 x 65 x 9.1 mm
approx. 11g
M3 Screw
Screw is not included.
0 to 55 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
RFID Sticker 1 sheet
Model Name : SEL41400L
■ Dimensions
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
4.2.2
TR3-A302
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Communication
distance
Connector
CN1
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz ±40kHz(Ta=25℃)
Max 7cm
(Communication distance depends on the environment.)
Connector : JST S2B-PH-SM4-TB(LF)(SN)
Housing : JST PHR-2
Contact : JST SPH-002T-P0.5S
Pin assignment
Pin No.
Mechanical
data
Ambient
Conditions
Other
Dimensions
(W x D x H)
Weight
Installation
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Specifications
4.2 Antenna
Symbol
RF
GND
Function
Analog signal
GND
15 x 52.5 x 9.1 mm
approx. 3g
M3 Screw
Screw is not included.
0 to 55 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
RFID Sticker 1 sheet
Model Name : SEL41400L
■ Dimensions
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.6mm
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
4.2.3
TR3-A401
■ Specifications
Specifications
Item
Applicable
RoHS
Standards
Antenna
Resonant
frequency
Communication
distance
Connector
CN1
Parameter
EU RoHS(2002/95/EC) Support
13.56MHz ±40kHz(Ta=25℃)
Max 5cm
(Communication distance depends on the environment.)
Connector : JST S2B-PH-K-S(LF)(SN)
Housing : JST PHR-2
Contact : JST SPH-002T-P0.5S
Pin assignment
Pin No.
Mechanical
data
Ambient
Conditions
Other
Dimensions
(W x D x H)
Weight
Installation
Temperature
Operating range
Humidity Operating
range
Temperature
Storage range
Humidity
Storage range
Accessories
Specifications
4.2 Antenna
Symbol
RF
GND
Function
Analog signal
GND
15 x 30 x 9.1 mm
approx. 2g
M3 Screw
Screw is not included.
0 to 55 degree
30 to 80%RH
0 to 55 degree
30 to 80%RH
RFID Sticker 1 sheet
Model Name : SEL41400L
■ Dimensions
Unit:mm
Tolerance:±1mm
Substrate thickness : 1.0mm
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
4
Specifications
4.3 Cable
4.3 Cable
4.3.1
TR3-AC-1A-***
■ Model Name
TR3-AC-1A-***
Enter the cable length(Unit:mm)
090~500
■ Specifications
Item
RoHS
Linetype
Connector
Cable loss
Parameter
EU RoHS(2002/95/EC) Support
Twisted pair cable
PH-PH
9cm : approx. 0.061dB
50cm : approx. 0.337dB
■ Dimensions
(Cable length)
( )is Recommended Dimension
4.3.2
TR3-AC-2A-***
■ Model Name
TR3-AC-2A-***
Enter the cable length(Unit:mm)
100~3M
■ Specifications
Item
RoHS
Linetype
Connector
Cable loss
Parameter
EU RoHS(2002/95/EC) Support
Coaxial cable 1.5D-2V
PH-PH
10cm : approx. 0.043dB
3m : approx. 0.255dB
■ Dimensions
(Cable length)
( )is Recommended Dimension
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
5 Maintenance
This product is mainly used in electronic components and semiconductors.
Therefore, the long-term stable operation, the environment and conditions are expected to defect, as
shown below.
• Device degradation due to overvoltage and overcurrent.
• Device degradation due to high temperature and long-term stress.
• Poor contact of the connector and cause deterioration of insulation by moisture
or dust.
• Connector corrosion by corrosive gases.
In order to use this product at its best, please conduct routine or periodic inspections.
Item
Maintenance
Criteria
Temperature
Temperature Operating range 0 to 55 degree
Humidity
Humidity Operating range
30 to 80%RH
Ambient
Enclosure
conditions
Check the dusty
None
rating
Corrosive
Check the corrosion
None
Input
Check the voltage
Power
Input Voltage : DC5V±10%
Voltage
Check the Voltage fluctuation
fluctuation
Check the Screw
Product
Checking and verifying
Attachment
Check the Connector
Cable
Check the Cable break
None
Performance
Check the Performance
Work
Manual No.TDR-MNL-C302-EN-100
TAKAYA RFID TR3 Series
Revision History
Revision code
1.00
Date
2014/11/05
Manual No.TDR-MNL-C302-EN-100
Revised contents
Original production
TAKAYA RFID TR3 Series
[URL]
[Mail]
http://www.takaya.co.jp/
rfid@takaya.co.jp
20

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : RF事業推進部 嶋津
Create Date                     : 2014:11:06 16:48:15+09:00
Modify Date                     : 2014:11:07 15:18:49+09:00
Language                        : ja-JP
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : RF事業推進部 嶋津
Creator Tool                    : Microsoft® Office Word 2007
Metadata Date                   : 2014:11:07 15:18:49+09:00
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:1a3345d1-768e-409e-bb5f-22fbebce941f
Instance ID                     : uuid:61ea8aaa-5d83-4648-a89c-2e824884c437
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MMFSATOTR3-C302

Navigation menu