Schlage Electronic Security VIPFP Door Lock User Manual 57032 A

Schlage Electronic Security Door Lock 57032 A

Contents

Manual 5100

Download: Schlage Electronic Security VIPFP Door Lock User Manual 57032 A
Mirror Download [FCC.gov]Schlage Electronic Security VIPFP Door Lock User Manual 57032 A
Document ID467556
Application IDA0ZS1zPYzi+UXwkHByY2YA==
Document DescriptionManual 5100
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize60.88kB (760997 bits)
Date Submitted2004-09-10 00:00:00
Date Available2004-09-09 00:00:00
Creation Date2004-02-13 21:58:47
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-08-11 13:44:18
Document Title57032-A.qxd
Document CreatorPScript5.dll Version 5.2
Document Author: ls_gld

VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
The VIP 5100 series lock is a microprocessor controlled, electromechanical locking system.
It is an open architecture product designed to interface with 3rd party panels ecompassing
all the features of the lock, reader, door status* and egress (rex/request to exit) indication in
one fire-rated piece of hardware. The 5100 employs a heavy-duty mechanical design tested
and complying with ANSI/BHMA grade 1 standards for performance and reliability. It is powered by 12 or 24 volts DC with only four wires required - two for power and two for communications. The lock communicates with a PIB (panel interface board) which communicates
with the panel as if it were separate components of an access control system.
Operationally, the outside lever is normally locked and the inside lever always retracts the
bolt to allow egress. Electronic access control is achieved by entering an”Access Credential”
(magnetic stripe card or Prox fob or card). The panel controls the lock through the PIB.
PX
MG
*Cylindrical model requires separate door status switch (included) to be installed in the door
and frame and connected to the VIP lock.
Please refer to all instruction manuals involved in the installation before you begin.
Functions:
VIP 5196-FSA: Cylindrical, Fail Safe (unlocked)
VIP 5196-FSE: Cylindrical, Fail Secure (locked)
Models:
MG:
Magnetic stripe card reader
PX:
HID Prox card reader
Standard Monitoring Switches:
DSM: Provides door status via data link to panel interface
KSM: Provides mechanical key use events via data link to panel interface
REX:
Provides indication of inside lever use for request to exit input via data link
to panel interface
Options:
T3:
Track 3 card reader (data must be ABA track 2 format) - MG only
EXT:
exterior use option - MG only (PX model has this standard)
KD:
Keyed Different, includes Schlage Everest cylinder
KA:
Keyed Alike, includes Schlage Everest cylinder
LC:
Less Cylinder
SLB:
OLB:
ELB:
PIB
Door Thickness Kits:
Available in 1/8” increments from 1-3/8” to 2-1/2”
2-3/4” backset, 1/2” latch bolt
2-3/8” backset, 1/2” latch bolt
2-3/4” backset, 3/4” latch bolt
BEFORE YOU BEGIN:
Standard units are shipped from the factory to fit 1-3/4” doors. Verify the
door thickness. If the door is not 1-3/4” thick, verify that the door thickness
option was ordered or consult factory.
5100 CYLINDRICAL
LOCKSET - STANDARD
PRE-INSTALLATION CHECK:
AN OPEN ARCHITECTURE SYSTEM REQUIRES AT LEAST THREE COMPONENTS - A PANEL INTERFACE BOARD (PIB), AN ACCESS CONTROL PANEL
(BY OTHERS) TO WHICH THE PIB IS CONNECTED AND THE VIP LOCK. SEE
DOCUMENTATION FOR THE ACCESS CONTROL PANEL/SOFTWARE THIS
LOCK WILL BE USED WITH FOR ANY PRE-INSTALLATION TESTING REQUIREMENTS AND REMEDIES. REFER TO THE WIRING INFORMATION INCLUDED
WITH THE PIB FOR MORE INFORMATION.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including any interference that may
cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
WIRE RACEWAY REQUIRED:
STANDARD WIRE
It is best to have the wire race way prepared at the door and
HARNESS THROUGH
frame manufacturer. If this has not been done there are two
HOLE
suggested preparation methods for making wire paths for the
FSE and FSA models in the field. Select method A or B;
depending on the door and frame circumstances, one may be METHOD A:
better than the other. Consult door manufacturer with any questions regarding agency listings with respect to fire integrity.
METHOD A:
1. Prep door and frame according to standard template.
2. Determine location of standard 1 inch wire harness through
WIRE RACE
hole and mark centerline of hole on hinge side of door.
3. Using appropriate drilling jig and drill bits, drill 3/8” or 1/2”
wire race from edge of hinge side into standard wire harness
through hole.
4. Install electric hinge or door cord and run wires.
METHOD B:
1. Prep door and frame according to standard template.
2. Using a 1” drill bit, continue the 1” latch hole through retractor
hole to a depth of 5”. This will allow room for the wiring to pass METHOD B:
around the retractor.
3. Using appropriate drilling jig and drill bits, drill 3/8” or 1/2”
wire race from the latch hole through the door toward the hinge
side. It is not necessary to continue drilling the hole through the
hinge side.
WIRE RACE
4. Measure up 3 inches from the center of the 2 1/8” retractor
hole and drill a 1 inch through hole on center as shown below.
5. Using a 3/8 inch drill bit, place the tip of the drill into the 1”
wire hole drilled in step 3 and aim at the angles shown. Drill
down and toward the hinge side to intersect the 1” latch hole
(where it was continued in step 2.
4. Install electric hinge or door cord and
run wires.
Note: this method offers the advantage of
not having holes exiting the door edges.
If a door cord is used the door cord wire
hole can be cross drilled into the long
wire race.
FSE & FSA HARD WIRED MODELS
REQUIRE WIRING TO BE RUN TO
THE LOCK PREP FROM THE HINGE
SIDE. BELOW IS A SUGGESTED
METHOD TO DO THIS. A DOOR CORD
OR ELECTRIC HINGE OR POWER
TRANSFER DEVICE IS USED TO
ROUTE WIRING FROM FRAME TO
DOOR. NOTE THAT WHEN USING AN
ELECTRIC HINGE IT IS RECOMMENDED THAT THE POWER WIRES
BE DOUBLED OR TRIPLED UP (ON
BOTH THE POSITIVE AND GROUND
LEGS) TO AVOID SIGNIFICANT VOLTAGE DROP THROUGH THE THIN
WIRES IN THE HINGE.
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
1. PREP DOOR AND FRAME:
A. Determine door hand and correct backset.
B. Mark the horizontal and vertical centerlines for the lockset, latch and strike.
C. Place template on inside of door (opposite the side that the keypad/reader will be on). Line up the correct reference lines
on the template with the edge of the door. The centerline on the door should line up with the vertical centerline of the template.
D. Drill holes as described by template.
DOOR FACE (LAY OUT ON INSIDE)
FRAME (STRIKE)
DOOR EDGE (LATCH)
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
2. INSTALL CYLINDER (IF NOT ALREADY DONE), GASKET AND STANDOFFS:
A. Install cam onto cylinder (if not already done.) Cam must be a straight 11/16” design. See below for recommended cams.
B. Insert mortise cylinder into outside escutcheon from front (keypad/reader) side with keyway down.
C. Slide lock washer onto cylinder (tab on top facing out, as shown below.)
D. Using nut tool (provided) tighten nut onto cylinder.
E. Line up nearest notch on nut with tab on lock washer and bend tab using nut tool so nut is secure.
F. Install exterior gasket (if used).
G. Install standoffs.
TEST KEY OPERATION NOW: Turning key clockwise until it stops (about 1/2 turn) should allow the lever to turn retractor.
RECOMMENDED CAMS:
SCHLAGE EVEREST: P/N B502-948
SCHLAGE CLASSIC: P/N B502-191
NOTE:
BLOCKING RING REQUIRED FOR CYLINDER
LENGTH GREATER THAN
1-1/8”.
THICKNESS = CYLINDER LENGTH - 1 1/8”
TAB
LOCK WASHER
NUT
CYLINDER
NUT TOOL
RETRACTOR ASSEMBLY
STANDOFFS
EXTERIOR GASKET
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
3. CHANGE HAND (IF NECESSARY):
NOTE: The locks are shipped handed as ordered from factory. follow the steps below to reverse the handing:
A. Remove retractor by loosening two 9/64” socket cap screws which attach it to the outside escutcheon.
B. Remove outside spindle.
C. Loosen 5/32” socket cap screw which secures handle to escutcheon.
D. Remove, rotate and re-install handle (NOTE: some handle designs have an adapter.)
E. Re-install outside spindle, making sure that the round end faces the handle, and the spindle is positioned with its edges
vertical and horizontal as shown in detail below. Note that the cam (inside the escutcheon assembly) must be positioned
such that the dot on it faces the 6 O’Clock position (see detail below).
F. Rotate retractor and re-install it.
G. Change the hand of the handle on the inside escutcheon (not shown) the same way. Note that the inside escutcheon has
no retractor.
DETAIL
OUTSIDE HANDLE
OUTSIDE
SPINDLE
CAM
POSITION
DOT
FACES
DOWN
OUTSIDE ESCUTCHEON
5/32”
SOCKET CAP
SCREW
9/64”
SOCKET CAP
SCREW
OUTSIDE SPINDLE
(ROUND
SIDE TOWARD LEVER)
RETRACTOR
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
4. INSTALL STRIKE BOX, STRIKE
AND DOOR SWITCH MAGNET:
5. INSTALL LATCH AND DOOR STATUS SWITCH:
A. Install latch into edge of door. Be sure to install it with the beveled edge facing door jamb.
B. Install switch as shown, passing switch wires through to the inside of the door.
Form 57032 Rev. A
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
6. INSTALL OUTSIDE ESCUTCHEON ASSEMBLY:
A. Remove latch guard from retractor.
B. If the door is less than 1-3/4” thick, install spacer plate provided.
C. Install outside escutcheon onto door (see detail for latch engagement). Pass wiring harness through wire hole.
D. Re-install latch guard onto retractor.
OUTSIDE ESCUTCHEON
WIRING HARNESS
DETAIL
SPACER
Prongs on latch must
engage with retractor.
(FOR
DOORS LESS THAN
1-3/4”)
LATCH GUARD
7. INSTALL INSIDE BASEPLATE ASSEMBLY:
DATA/POWER WIRES COME
FROM HERE IF WIRING
METHOD “B” WAS USED.
PASS THE WIRES THROUGH
THIS HOLE. (IF A SPACER IS
USED DRILL A HOLE IN THE
SPACER PLATE FOR WIRES TO
PASS THROUGH.)
SOCKET CAP SCREW,
WASHERS
SPACER
(FOR
DOORS LESS THAN
1-3/4”)
PHILLIPS HEAD
SCREWS
Form Form 57032 Rev.
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
8. MAKE WIRING HARNESS CONNECTIONS :
A. Plug MAIN WIRING HARNESS into PC board.
B. Plug MAKE FIELD CONNECTIONS TO TERMINAL BLOCK.
C. Pug in DOOR STATUS SWITCH as shown.
D. Verify correct lock type setting (FSE/FSA) - see dip switch setting. Note: as ordered from the factory.
E. If lock is the one farthest away from PIB set termination resistor to “on”. All others should be in the “off/parked” position.
F. Test operation of inside lever to make sure that latch retracts fully.
IMPORTANT! See PIB manual for additional connecting instructions.
TERMINATION
RESISTOR:
OUTSIDE
MAIN HARNESS
CONNECTION
OFF
(PARKED)
ON
DOOR SWITCH
SHIELD
DATA A
DATA B
GROUND
V+
1.0A @ 12VDC
0.5A @ 24VDC
REX INPUT
(PLUG IN WHEN INSIDE
ESCUTCHEON IS
INSTALLED)
FIELD WIRING FROM
PANEL AND POWER
SUPPLY.
DIP
SWITCH
NUMBER:
1:
2:
LOCK ADDRESS (SEE CHART)
LOCK ADDRESS (SEE CHART)
3:
4:
ALWAYS SET TO OFF
ALWAYS SET TO OFF
5:
OFF = FAIL SECURE (FSE)
ON = FAIL SAFE (FSA)
6:
OFF = ALL MG LOCKS
ON = ALL PX LOCKS
ALWAYS SET TO OFF
ALWAYS SET TO OFF
ALWAYS SET TO OFF
ALWAYS SET TO OFF
7:
8:
9:
10:
Form 57032 Rev. A
LOCK
ADDRESS
LOCK
ADDRESS
LOCK
ADDRESS
LOCK
ADDRESS
DIP SWITCH
OFF
ON
OFF
ON
DIP SWITCH
OFF
OFF
ON
ON
Note:
Lock addresses must be used in sequence and cannot
be the same for any two locks connected to a PIB. For
example, if the system has three locks, use addresses
1, 2, and 3 (but not 4). Lock address will correspond to
panel address on the PIB.
01-05-2004
VIP 5100 OPEN ARCHITECTURE CYLINDRICAL LOCK
INSTALLATION MANUAL
9. INSTALL INSIDE ESCUTCHEON:
Install inside escutcheon assembly onto inside baseplate
using four screws.
IMPORTANT!
1. MAKE SURE THAT INSIDE SPINDLE IS
INSTALLED.
2. PLUG REX SWITCH IN TO BOARD.
3. DO NOT PINCH WIRES BETWEEN PARTS.
PLUG REX SWITCH
INTO PC BOARD
INSIDE SPINDLE
DO NOT PINCH WIRES
FOR REX SWITCH
BETWEEN PARTS
10. SEE PIB MANUAL AND SYSTEM/PANEL MANUAL FOR SET UP PROCEDURES.
Form 57032 Rev. A
01-05-2004

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2004:02:13 21:58:47Z
Modify Date                     : 2004:08:11 13:44:18-03:00
Page Count                      : 9
Creation Date                   : 2004:02:13 21:58:47Z
Mod Date                        : 2004:08:11 13:44:18-03:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : ls_gld
Metadata Date                   : 2004:08:11 13:44:18-03:00
Creator                         : ls_gld
Title                           : 57032-A.qxd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P2GVIPFP

Navigation menu