The VIP993 series lock is a microprocessor controlled,electromechanical locking system which bolts on to newor existing Von Duprin 98 & 99 rim and vertical rod exitdevices. It is an open architecture product designed tointerface with 3rd party access control panels encom-passing all the features of the lock, reader, door statusand egress (rex/request to exit) indication in one pieceof hardware. It is powered by 12 or 24 volts DC withonly four wires required to the door - two for power andtwo for communications. For door status indication adoor switch (included) must be installed. For request toexit (REX) the Von Duprin exit device must be equippedwith the exit indication switch (order a RX-LC98/99 exitdevice or Von Duprin P/N S1-LC for an aftermarket application)and a pair of wires (included) must be run from the switchto the VIP993. The lock communicates with a PIB (panelinterface board) which communicates with the panel as if itwere separate components of an access control system.Operationally, the outside lever is normally locked the exitdevice allows free egress. Electronic access control isachieved by entering an”Access Credential” (magneticstripe card or Prox fob or card). The panel controls the lockthrough the PIB.Compatible Von Duprin exit device models include:98/999827/99279847/88479848/99489857/9957 Form 61997 Rev. A 01-05-20041VIP993 OPEN ARCHITECTURE TRIMHARD-WIRED INSTALLATION MANUALMG-FSAMG-FSEPX-FSAPX-FSEPIBThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this devicemay not cause harmful interference, and (2) this device must accept any interference received, including any interferencethat may cause undesired operation. Changes or modifications not expressly approved by the party responsible for com-pliance could void the user’s authority to operate the equipment.
- PAGE 2 -Form 61997 Rev. AVIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIRED01-05-2004TWOCENTERSCREWS1. PREP DOOR: Remove exit bar and modify door prep with additional holes required for trim pertemplate below (or use paper template provided). DOOR SHOWN PREPPEDFOR VON DUPRIN TRIM.ACTUAL EXISTING DOORPREP (IF ANY) MAY VARY.
- PAGE 3 -Form 61997 Rev. AVIP993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIRED01-05-20042. PREPARE FOR AND INSTALL DOOR STATUS SWITCH & MAGNET: Measure down 6” fromthe horizontal centerline of the exit device on both the door and the frame. Centered on the dooredge drill a 3/4” hole 2” deep to intersect the 3/8” hole on the trim side. On the frame drill a 1” hole2” deep directly opposite the 3/4” hole on the door. Install the magnet in to the frame. Install theswitch into the door, passing the wires through the hole in the face of the trim side as shown.NOTE: This door switch location has been determined to be the best for most door and frame con-ditions. It is possible that certain existing door and frame conditions may require the switch to belocated in a different position. Door switch wires must still exit the door face through the hole asshown. 6”3/4” HOLE2” DEEPFORSWITCH 1” HOLE2” DEEPFORMAGNETDOORCENTERLINETRIM SIDE OFDOORFRAME RABBET
- PAGE 4 -FORM 60993 Rev. AVIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIRED01-05-20043. INSTALL CYLINDER, GASKET AND STANDOFFS:A. Install cam onto cylinder (if not already done.) B. Insert standard, 1-1/8” mortise cylinder into outside escutcheon from front (keypad/reader) side with keyway down.C. Slide lock washer onto cylinder (tab on top facing out, as shown below.)D. Using nut tool (provided) tighten nut onto cylinder.E. Line up nearest notch on nut with tab on lock washer and bend tab using nut tool so nut is secure. F. Install four standoffs.CYLINDERNOTE:BLOCKING RING REQUIRED FOR CYLINDERLENGTH GREATER THAN 1-1/8”.THICKNESS = CYLINDER LENGTH -1 1/8”RECOMMENDED CAM:SCHLAGE EVEREST: P/N B502-948SCHLAGE STANDARD: P/N B502-191NUT TOOLLOCK WASHERNUTSTANDOFFSTAB
- PAGE 5 -VIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIREDForm 61997 Rev. A 01-05-20044. RE-INSTALL EXIT DEVICE: (Re)-Install exit bar, but  only install 2 center screws (see templateinfo on page 2) in the centercase at this time, leave center case cover off.5. SET HAND OF TRIM (IF REQUIRED):A. Install lever using hex head screw and 5/32” allen wrench as shown.B. TEST: Use key override to engage lever to test for cam rotation. Output cam should be observed to rotate when lever is depressed. 6. INSTALL STOP SCREW:A. Push down on lever, observe output cam rotate, then install stop screw as shown below (while keeping the lever depressed).B. TEST:  Lever should rotate down, when pushed; lever should not lift up.LHR RHR SCREWCAM7. PREP EXIT DEVICE:  Set exit device toNL (“Night Latch”) function by inserting theallen set screw (supplied in screw pack) asshown in illustration to right. If the set screwis present go to next step.
- PAGE 6 -FORM 60993 Rev. AVIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIRED01-05-20048. ROUTE VIP993 HW WIRES THROUGH EXIT DEVICE.a. Slide mechanism case 2” away from center caseb. Push VIP993HW cables down length of the device between mechanism case and base plate.Leave 12” of cable protruding from center case end of device.c. Push VIP993 HW cable through opening in bottom of center case.d. Slide mechanism case back against center case.Important!Be careful not to pinch cables when slidingmechanism case back against center case.RHR LHRRHR LHR2” 2”MECHANISMCASEBASE PLATECENTER CASELEAVE 12” OFWIRE PROTRUDINGMECHANISMCASEBASE PLATECENTER CASELEAVE 12” OFWIRE PROTRUDING
- PAGE 7 -VIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIREDForm 61997 Rev. A 01-05-20049. RE-INSTALL EXIT DEVICE: Carefully fish wiring from exit device through latch head wire holeand through door. Fish wiring from door switch through hole in trim as shown.Install exit device ontodoor. Place spindle into exit device.  The end of spindle with the identifica-tion notches inserts into the cam in the centercase for RHR. For LHR theend of the spindle with the notches inserts into the trim as shown below.(See DETAIL)10. ENGAGE SPINDLE AND TEST: Fish wiring through VIP993 wire hole.Align spindle with lever and place trim onto door.  The unlocked levershould retract the latch fully.  If there is only a partial retraction of the latchthe spindle is in backwards.  If the lever can not be pushed down the leverstop screw is not in the correct hole. (See step 6 to correct this.) 11. SECURE TRIM: Install 4 screws to secure trim to door / latch head. NOTCHED ENDINSERTS INTOTRIM FOR LHR.(INSERTS INTOBAR FOR RHR)LHR SHOWNRHR ISOPPOSITENOTE: The tab on the spindle, whichengages the exit device latch head, issized for optimal performance in mostinstallations. Older exit devices may havecams which are smaller and do not allowthe spindle to fit. In these cases, the tabmay be filed to fit the cam. Do not over-fileor full bolt retraction will be lost.IF THESE TWOSCREWS WEREPRESENT INTHE ORIGINALINSTALLATION,RE-INSTALLTHEM.IMPORTANT!SIDE OF SPINDLE WITH LONGERSTEP GOES AGAINST RAISED “C”SHAPE AREA OF CAM ON LATCHHEAD.DETAILWIRES FROMEXIT DEVICEWIRES FROMDOOR SWITCH
- PAGE 8 -VIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIREDForm 61997 Rev. A 01-05-2004OFF (PARKED)ONTERMINATIONRESISTOR:DOOR STATUSSWITCH INPUT(YELLOW WIRES)DOOR STATUSSWITCHREX SWITCH INPUTFROM EXIT DEVICE (2-CONDUCTORWIRE RED/WHITE)12. MAKE WIRING HARNESS CONNECTIONS :A. Connect 4-conductor shielded wire (from exit device) to 5 position terminal block.B. Connect 2-conductor wire (from REX switch in exit device) to terminal block.C. Connect in DOOR STATUS SWITCH as shown.D. Set lock address. See dipswitch settings on next page.E. Verify correct lock type setting (FSE/FSA) - see dip switch setting. Note: as ordered from the factory.F. If lock is the one farthest away from PIB set termination resistor to “on”. All others should be in the “off/parked” posi-tion.IMPORTANT! See PIB manual for additional connecting instructions.SHIELD (N/A - METAL)DATA A WHITEDATA B GREENGROUND BLACKV+ REDSEE NEXT PAGEFOR DIP SWITCHSETTINGS
- PAGE 9 -VIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIREDForm 61997 Rev. A 01-05-200413. REX switch connection:On the inside of the exit device:Connect the 2-conductor black and white wire to the S-1 switch installed on the exit device to theyellow and blue wires (it doesn’t matter which is connected to which). Be sure to connect themsecurely so they don’t disconnect during operation.Note: if the REX switch (S-1) is not used, see the information supplied with the panel to set up thedoor zone without a rex/legal egress input to avoid a fault condition.1: LOCK ADDRESS (SEE CHART)2: LOCK ADDRESS (SEE CHART)3: ALWAYS SET TO OFF4: ALWAYS SET TO OFF5: OFF = FAIL SECURE (FSE)ON = FAIL SAFE (FSA)6: OFF = ALL MG LOCKSON = ALL PX LOCKS7: ALWAYS SET TO OFF8: ALWAYS SET TO OFF9: ALWAYS SET TO OFF10: ALWAYS SET TO OFFLOCKADDRESS1LOCKADDRESS2 LOCKADDRESS3 LOCKADDRESS4 DIP SWITCH1 OFF ON OFF ONDIP SWITCH2 OFF OFF ON ONDIPSWITCHNUMBER:Note:Lock addresses must be used in sequence and cannotbe the same for any two locks connected to a PIB. Forexample, if the system has three locks, use addresses1, 2, and 3 (but not 4). Lock address will correspond topanel address on the PIB.DIP SWITCH SETTINGS:
- PAGE 10 -FORM 60993 Rev. AVIP 993 OPEN ARCHITECTURE TRIMInstallation Instructions - HARDWIRED06/29/200114. INSTALL PC BOARD COVER:See PIB manual and panel documentation for more wiring and set up information.