Schneider Electric Systems Canada OM240 2.4GHz frequency hopping spread spectrum rf module User Manual O Series 08 08 indd

Trio Datacom Pty Ltd (a wholly owned company of Schneider Electric) 2.4GHz frequency hopping spread spectrum rf module O Series 08 08 indd

Contents

Users Manual 2

Download: Schneider Electric Systems Canada OM240 2.4GHz frequency hopping spread spectrum rf module User Manual O Series  08 08 indd
Mirror Download [FCC.gov]Schneider Electric Systems Canada OM240 2.4GHz frequency hopping spread spectrum rf module User Manual O Series  08 08 indd
Document ID996838
Application IDNNFgLzFkGMqhjkjaugjnxA==
Document DescriptionUsers Manual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize260.86kB (3260720 bits)
Date Submitted2008-09-08 00:00:00
Date Available2008-09-08 00:00:00
Creation Date2008-08-08 14:02:00
Producing SoftwareAdobe PDF Library 6.0
Document Lastmod2008-08-29 09:58:01
Document TitleO Series User Manual 08-08.indd
Document CreatorAdobe InDesign CS (3.0.1)

10
13
11
12
R2out
R1out
T2in
T1in
C2-
C2+
C1-
C1+
nSHDN
nEN
note: Radio inputs are 5V tolerant, however 3V3 is recommended.
Radio PIN 24
Radio PIN 7
Radio PIN 8
C4
100n
C3
100n
20
GND
16
R2in
R1in
T2out
T1out
Vs-
Vs+
MAX3222E
VCC
Page 15
17
+3V3
14
15
100n
C5
100n
C2
U1
C1
100n
C10
100p
C8
100p
C6
100p
R4
100R
R2
100R
R1
100R
C11
100p
C9
100p
C7
100p
Optional EMC components
DiagsOut
DiagsIn
R3
3K3nPTT
+3V3
SYSTEM RS232
SERIAL INTERFACE
P1
P2
P3
P4
P5
P6
P7
P8
J8
J7
J6
J5
J4
J3
J2
J1
X1
O Series Data Radio – User Manual
System Port Interface
© Copyright 2008 Trio DataCom Pty. Ltd.
M2
M1
O Series Data Radio – User Manual
Power Supply Filtering
Page 16
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Part G – Mounting and LED Indicators
Mounting & Connector Information
Please Note : Mating connectors can be supplied with each radio or seperately. Please order as part number SM%CO2241-20X2
Page 17
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Antenna Port Cabling (Hazardous Installations)
When the O Series OEM module is intended to be used in equipment which is compliant with Class I, Division 2 - Groups A,B,C,D Hazardous
Locations, the antenna conenctors need to be retained using a soldered connection as shown in the diagrams below. The method of soldered
retention will depend on the model of O Series OEM product in use. See below for model specific guidlines.
For O Series modules that have integtel mounting tabs, solder the TAB to the RF connector.
For O Series modules that have no TAB, solder a wire from the shield lid to the connector.
Page 18
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Product Labelling
When this OEM module is housed inside another unit, the unit
must be labelled with the following notice :
“This unit contains a device with FCC ID:
900MHz Modules:
NI8OM900 and IC: 4630A-OM900.
2.4GHz Modules:
NI8OM240 and IC: 4630A-OM240.
This device complies with part 15 of the FCC rules. Operation of
this device is subject to the following conditions:
(1) this device may not cause harmful interference, and (2) this
must accept any interference received, including interference that
may cause any undesired operation.”
LED Indicators
Indicators
Power LED
Sync/NoRx LED
Port A Activity
Port B Activity
Page 19
Legend
Tx Power (Red) / DC Power (Green)
Masters:
100ms pulse when user data received (Green)
Remotes/Bridges:
Pulsed every 1500ms for 100ms when master acquired, additional 100ms
pulse when user data received (Green)
Pulsed every 1500ms for 100ms when master not acquired (Red)
Pulsed for 100ms for any TxD activity on Port A TXD (Red)
Pulsed for 100ms for any RxD activity on Port A RXD (Green)
Pulsed for 100ms for any TxD activity on Port BA TXD (Red)
Pulsed for 100ms for any RxD activity on Port B RXD (Green)
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Part H – Programming and Diagnostics
Programming
The O Series OEM module is programmed via the System Port.
There are two methods of programming:
(a) In Situ : Programming via the 3-wire System Port pins
(b) In K-Series : OEM Module can be plugged into a K Series
carrier PCB and programmed via the System Port on the K
Series.
The O Series OEM module is programmed using the TVIEW+
Management Suite : K Series programmer.
Programming of the O Series is similar to the K Series - however
some features are optional on the O-Series (dependent on external
support circuitry). The features that require external support
circuitry which may or may not be relavent to your design are:
(a) RS-485 .
(b) Multi-master Synchronisation.
(c) RSSI Output
(d) Port B
(a) Port A & B Hardware handshaking signals
For a comprehensive guide to programming the O Series OEM
module, please refer to the TVIEW+ K Series User Manual - Part
G.
Diagnostics
The O Series OEM module includes diagnostics which is useful for
fault finding and system commisioning. Detailed information about
O Series diagnostics is available in the TVIEW+ Diagnostics User
Manual.
TVIEW+ Diagnostics is available via the System Port of the O
Series module. To access the diagnostics facilities locally, the
System Port of the O Series must be brought out to a connector for
connecion to the computer running the diagnostics package.
Alternatively, remote diagnostics connectivity is available “over-theair”. More information on configuring diagnostics can be found in
both the TVIEW+ Diagnostics User Manual and the K Series User
Manual.
The OEM user may also wish to integrate O Series diagnostics
into their own application. To facilitate this, Trio Datacom can
provide the specifications document for the “Remote Diagnostics
Protocol”. This document specifies how diagnostics messages
are constructed and what facilities are available. To obtain this
document, please contact the factory on support@triodatacom.
com.
Page 20
© Copyright 2008 Trio DataCom Pty. Ltd.
C
© Copyright 2008 Trio DataCom Pty. Ltd.
ISSUE
A2
A3
A3
B1
B2
C1
D1
10-30v
TEMPERATURE
SENSOR
(U4)
SIO
SHUTDOWN
RS-232
DRIVERS
(U7)
INPUT
FILTER
(FL1)
NVRAM
(U5)
CROWBAR
CIRCUIT
(Q2)
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
(X1)
SYSTEM PORT
Page 21
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
I2C BUS
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
(X9)
C COPYRIGHT
2007
PCB No. 195-01-100
REV. D
+3.3V
LINK
FIELDS
(X5)
RS-232/RS-485
DRIVERS
(U7) (U9)
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
TRIO DATACOM Pty. Ltd.
RSSI
RS-232
DRIVERS
(U6)
GP OUTPUT
GP INPUT
LINK
FIELDS
(X7) (X10)
FACTORY
DEFAULTS
SWITCH
5V to 3.3V
REGULATOR
(U2)
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
SW1
INPUT
FILTER
INPUT
FILTER
O-SERIES MODULE
+3.3V
+5V
+5V
(10-30V)
to 5V
REGULATOR
(U1)
11-Jul-07
OF
CHKD: RG
SHT: 3
DRN: P Hogan
FILE: 195-00-100-Block.SchDoc
DATE:
REV: D1
K-Series Block Diagram
LINK
FIELDS
(X4)
LINK
FIELDS
(X6) (X8)
DWG No.: 195-00-100
TITLE:
PORT A
(X2)
PORT B
(X11)
A3
SIZE
O Series Data Radio – User Manual
Part I – K Series PCB Overlay & Schematics
Schematics
D
ISSUE
A2
A3
A3
B1
B2
C1
D1
C67
1n
D16
BAV99W
D15
BAV99W
D14
BAV99W
D13
BAV99W
R52
15K
R53
1K
VIN-
VIN+
R34
1K
Vset
R32
10K
R30
2K2
F1
3A
PSG
C49
1u
U3
LM431
R33
1K
CG
CB
R37
220R
SCRgate 1
Q2
MCR708AT4G
Q1
BC857W
R31
10K
TP1
Input Filter & Protection
FL1
BNX012-01
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
ENABLE
SUPPLY-MONITOR
X3
POWER INPUT
(10~30VDC)
D3
SMCJ33A
VINSW
C43
220n
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
11
10
EN
IN
IN
nc
nc
nc
nc
nc
CB
VSW
DAP VSW
VSW
FB
U1
LM2676SD-ADJ
R29
1K
14
13
12
VSW
FB
C35
10n
Step-Down Switcher
C COPYRIGHT
2007
PCB No. 195-01-100
REV. D
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
TP4
(ESR = 65mOHM per cap)
C40
C41
C42
56u 35V 56u 35V NF (56u 35V)
HIGH=ENABLE
L1
22uH
C39
100p
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
D1
SS26
VINF
DAP
GND
R27
NF (68K)
R28
3K3
(Total ESR = 100mOHM)
C45
100u
D12
SS26
VIN
TP3
TP2
OF
C2
10u
+3V3
+5V2
+5V2-MOD
CHKD: RG
SHT: 5
DRN: P Hogan
REV: D1
VOUT
U2
LP38690DT-3.3
FILE: 195-00-100-PSU.SchDoc
11-Jul-07
DWG No.: 195-00-100
DATE:
C1
10u
K-Series PSU
C75
1000u 6.3V
R22
NF (0R0)
TITLE:
C66
1000u 6.3V
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
C44
100u
C36
FT22n
POWER SUPPLIES
TRIO DATACOM Pty. Ltd.
D2
SS26
L2
47uH
keep separated !
21
21
21
GND
Page 22
A3
SIZE
O Series Data Radio – User Manual
© Copyright 2008 Trio DataCom Pty. Ltd.
D
ISSUE
A2
A3
A3
B1
B2
C1
D1
VCC
WP
SCL
SDA
+3V3
NVRAM
NC
NC
NC
GND
U5
24LC01
C69
100n
R107
4K7
R1
220R
R21
10K
C81
100n
D18
BAV99W
SDA
SCL
OS
GND
VCC
A0
A1
A2
U4
NF (LM75A)
+3V3
SW1
SKQLLA
C9
100n
R11 220R
TEMPERATURE
SENSOR
R2
220R
NVRAM-WP
Restore Defaults
D19
BAV99W
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
TEST-MODE
+3V3
R3
4K7
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
PORTB-TXD
PORTB-RXD
PORTB-RTS
PORTB-CTS
PORTB-DTR
PORTB-DCD
34
33
32
31
30
29
40
39
38
37
36
35
23
24
20
21
18
19
17
15
22
16
C6
10u
NVRAM-WP
RxSIG-LED
SHUTDOWN-OUT
SUPPLY-MONITOR
TWCK
TWD
PORT1-DCD
PORT1-DTR
PORT1-CTS
PORT1-RTS
PORT1-RxD
PORT1-TxD
C7
10u
PORT2-CTS
PORT2-RTS
PORT2-DTR
PORT2-TxD
PORT2-RxD
PORT2-DCD
C COPYRIGHT
2007
REV. D
C4
FT22n
C8
100n
220R
220R
220R
R7
R8
R9
R10 220R
220R
R6
220R
R5
220R
R4
+3V3
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
25
26
28
27
13
L4
FB8530
TRIO DATACOM Pty. Ltd.
Tx-INHIBIT
SHUTDOWN-IN
HOP-SYNC-OUTPUT
HOP-SYNC-INPUT
ANALOG-RSSI
Radio Module
PORT0-SysSerIn
PORT0-SysSerOut
nFACT/TEST-MODE
PTT
TxD-PORT2-LED
RxD-PORT2-LED
TxD-PORT1-LED
RxD-PORT1-LED
SYNC-LED
Tx-LED
DC-POW-LED
ANALOGUE-INPUT
X9
C3
FT22n
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
R12 220R
R14 220R
C5
100n
L3
FB8530
+5V2-MOD
PCB No. 195-01-100
R20 220R
R19 220R
R18 220R
R17 220R
R16 220R
R15 220R
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
MODULE-RX-SIG-LED
nSHUTDOWN-OUT
SUPPLY-MONITOR
MODULE-DIAGS-SER-IN
MODULE-DIAGS-SER-OUT
PTT
PORTA-TXD-LED
PORTA-RXD-LED
PORTB-TXD-LED
PORTB-RXD-LED
MODULE-Rx-SYNC-LED
MODULE-Tx-LED
MODULE-DC-POW-LED
GP-INPUT
11
GND
VCC
12
10
PAVCC
PAVCC
GND
Page 23
14
11-Jul-07
OF
CHKD: RG
SHT: 6
DRN: P Hogan
FILE: 195-00-100-RadioModule.SchDoc
DATE:
REV: D1
K-Series RF Module
DWG No.: 195-00-100
TITLE:
Tx-INHIBIT
nSHUTDOWN-IN
MULTISYNC-OUTPUT
MULTISYNC-INPUT
RSSI-OUT
PORTA-CTS
PORTA-RTS
PORTA-DTR
PORTA-TXD
PORTA-RXD
PORTA-DCD
A3
SIZE
O Series Data Radio – User Manual
© Copyright 2008 Trio DataCom Pty. Ltd.
D
ISSUE
A2
A3
A3
B1
B2
C1
D1
17
22
21
19
18
14
13
12
10
R2-OUT
R2-OUT
R1-OUT
T1-IN
T2-IN
T1-IN
T2-IN
T1-IN
C2-
C2+
C1-
C1+
R2-IN
R2-IN
R1-IN
T1-OUT
T2-OUT
T1-OUT
T2-OUT
T1-OUT
V-
V+
16
23
20
24
15
11
C10
100n
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
R40
100R
R38
100R
R35
100R
R26
100R
R25
100R
R24
100R
R23
100R
+5V2
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
2K2
R99
C27
100p
C25
100p
C23
100p
C21
100p
C19
100p
C15
100p
C12
100p
R101 R102 R103 R104 R105
270R 270R 270R 270R 270R
C18
100n
C11
100n
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
PORTB-RTS
PORTB-DTR
PORTB-TXD
PORTB-CTS
PORTB-RXD
PORTB-DCD
C17
100n
C14
100n
U6
ICL3207IAZ
C80
100p
2K2
R100
R106
3K3
C COPYRIGHT
2007
PCB No. 195-01-100
R45
NF (10K)
R43
NF (22K)
C64
100p
Q9
BC817W
R85
3K9
HDR4X2
X11
REV. D
C29
NF (1n)
+3V3
Q5
BC817W
D11
BAV99W
R60
39K
C73
NF
U10
NF (LMV321IDCKR)
R75
15K
R72
15K
R69
1K8
R70
3K3
C71
1n
GP-INPUT
MULTISYNC-OUTPUT
X4
R77
220K
11-Jul-07
OF
RSSI-OUT
CHKD: RG
SHT: 8
DRN: P Hogan
REV: D1
FILE: 195-00-100-RS232PORTB.SchDoc
DATE:
R36
470K
MULTISYNC-INPUT
R42
47K
M1
K-Series RS-232 Port B
C68
1n
DWG No.: 195-00-100
TITLE:
R41
47K
U8
LMV321IDCKR
D17
NF (SMBJ24A)
+5V2
C70
100n
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
+3V3
+5V2
C74
NF
R90
NF (47K)
Q4
BC857W
R66
3K9
Q6
NF (BSP-295)
R92
NF (100R)
R39
47K
DCD-B
DSR-B
RXD-B
RTS-B
TXD-B
CTS-B
DTR-B
User-Out
TRIO DATACOM Pty. Ltd.
+5V2
D4
NF (BAV99W)
R61
100R
User-RSSI
GP-Out
PORT B RS232 SERIAL INTERFACE
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
D20
BAV99W
C28
100p
C26
100p
C24
100p
C22
100p
C20
100p
C16
100p
C13
100p
GPS
VCC
GND
Multisync
+3V3
Page 24
M2
A3
SIZE
O Series Data Radio – User Manual
© Copyright 2008 Trio DataCom Pty. Ltd.
D
ISSUE
A2
A3
A3
B1
B2
C1
D1
RS485-TXD
R73
100R
R65
NF (22K)
BAV99W
D21
17
R76
22K
D9
NF (BAV99W)
R63
NF (22K)
22
R62
NF (22K)
+3V3
RS-232
RS-485
D6
NF (BAV99W)
X10
LK1
21
19
SPTx
D7
NF (BAV99W)
R2-OUT
R2-OUT
R1-OUT
T1-IN
T2-IN
T1-IN
T2-IN
T1-IN
C2-
C2+
C1-
C1+
C65
220n
R2-IN
R2-IN
R1-IN
T1-OUT
T2-OUT
T1-OUT
T2-OUT
T1-OUT
V-
V+
+3V3
R98
22K
R91
10K
+3V3
+3V3
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
A/Y
B/Z
Q10
BC817W
+3V3
D8
BAV99W
C78 C79
NF NF
R79
0R0
C76 C77
NF NF
R78
0R0
D10
BAV99W
C COPYRIGHT
2007
PCB No. 195-01-100
REV. D
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
22K
22K
D5
BAV99W
R67
DI
DE
RE
RO
U9
ISL8485IBZ-T
R108
Q11
BC857W
R56
22K
PORTA-DCD
Q3
BC817W
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
Q7
BC857W
R97
47K
LK-SOLDER-1WAY-BRIDGED
LK2
NF (TP-100)
X7
NF (TP-100)
RS-485
RS-232
TP6
C47
100n
PORTA-RXD
RS485-TXD
C72
100n
TP5
R74
470R
16
23
20
24
15
11
C33
100n
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
ENABLE
nSHUTDOWN-OUT
nSHUTDOWN-IN
Tx-INHIBIT
PTT
MODULE-DIAGS-SER-IN
PORTA-RTS
PORTA-DTR
PORTA-TXD
PATx
SPRx
PORTA-RXD
18
14
13
12
PORTA-DCD
PARx
MODULE-DIAGS-SER-OUT
PORTA-CTS
PORTA-RXD
PORTA-DCD
C46
100n
C38
100n
10
U7
ICL3207IAZ
C32
100n
+5V2
VCC
+3V3
GND
VCC
GND
R13
4K7
C60
100p
C58
100p
C56
100p
C54
100p
C52
100p
C50
100p
C37
100p
C31
100p
X6
RS-485
RS-232
RS-485
RS-232
P1
P2
P3
P4
P5
P6
P7
P8
R44
1K
P1
P2
P3
P4
P5
P6
P7
P8
11-Jul-07
J2
J1
J8
J7
J6
J5
J4
J3
J2
J1
J8
J7
J6
J5
J4
J3
OF
CHKD: RG
SHT: 7
DRN: P Hogan
REV: D1
FILE: 195-00-100-RS232SYSTEM-PORTA.SchDoc
DATE:
X2
X1
K-Series RS-232 System Port and Port A
DWG No.: 195-00-100
TITLE:
R71
3K3
+5V2
X13
A3
SIZE
R96
100R
R95
100R
SYSTEM RS232
SERIAL INTERFACE
RXD-A
TXD-A
CTS-A
RTS-A
DSR-A
DCD-A
DTR-A
nShutdown
TxInhibit
nPTT
Term
Unterm
R94
100R
R93
100R
PORT A
SERIAL INTERFACE
DiagsOut
DiagsIn
+12V on E-Series
TEST-MODE
X8
R58
3K3
+3V3
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
C63
100p
R68
22K
R59
22K
R57
22K
R55
100R
R54
100R
R51
100R
C53
100p
R50
100R
C51
100p
100R
R49
R48
100R
R47
100R
R46
100R
TRIO DATACOM Pty. Ltd.
R109
NF (47K)
C62
100p
C61
100p
C59
100p
C57
100p
C55
100p
C48
100p
C34
100p
C30
100p
M2
M1
M1
Page 25
M2
O Series Data Radio – User Manual
© Copyright 2008 Trio DataCom Pty. Ltd.
D
ISSUE
A2
A3
A3
B1
B2
C1
D1
VIN

VOUT
VOUT




R84
1K
CHANGE DETAILS
ECO No.
See Bugzilla Bug # Upissued to A2 and frozen
N/A
Upissued to A3
N/A
See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877
Up issued to B1 and frozen.
N/A
Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF.
PCB Rev C and schematic update. See ECN.
N/A
PCB Rev D Schematic update see ECN sheet
N/A
FROM RADIO MODULE

+5V2
GND
DRAWN
G. Rankin
G. Rankin
G. Rankin
G. Rankin
BWA
BWA
PAH
PORTB-RXD-LED
PORTB-TXD-LED
PORTA-RXD-LED
PORTA-TXD-LED
MODULE-Rx-SYNC-LED
MODULE-RX-SIG-LED
MODULE-DC-POW-LED
MODULE-Tx-LED
DATE
21/02/07
22/03/07
22/03/07
22/03/07
23/05/07
30/05/07
19/06/07
+3v3_LED
+3v3_LED
+3v3_LED
+3v3_LED
C COPYRIGHT
2007
PCB No. 195-01-100
REV. D
41 Aster Avenue. Carrum Downs.
Victoria. Australia. 3201
TRIO DATACOM Pty. Ltd.
"TxD" = red, "RxD" = green, BOTH "TX & RX" = amber
H5
KPBL-3025SURKMGKC
"TxD" = red, "RxD" = green, BOTH "TX & RX" = amber
H4
KPBL-3025SURKMGKC
H3
NF (KPBL-3025SURKMGKC)
"RxSIG" = red, "Sync" = green
H2
KPBL-3025SURKMGKC
"Tx" = red, "Pwr" = green (default condition)
H1
KPBL-3025SURKMGKC
THIS DRAWING IS CONFIDENTIAL INFORMATION
Disclosure of this information, whether all or part thereof, cannot be
made to a 3rd party without the written consent of Trio Datacom
Pty. Ltd. Trio Datacom Pty. Ltd. reserves the right to change
documentation in the light of technical advancement.
R89
51R
R88
390R
R87
51R
R86
390R
R83
51R
R82
390R
R81
51R
R80
390R
+3v3_LED
STATUS LEDS
Page 26
11-Jul-07
OF
CHKD: RG
SHT: 9
DRN: P Hogan
FILE: 195-00-100-StatusLEDs.SchDoc
DATE:
REV: D1
K-Series Status LEDs
DWG No.: 195-00-100
TITLE:
A3
SIZE
O Series Data Radio – User Manual
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Overlay
Page 27
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Part I – Specifications
Parameter
900MHz Specification
FCC: 902 – 928MHz, ACMA:
915-928MHz
50Ω
2.4GHz Specification
2.4 - 2.4835MHz
Main Antenna Connector Type:
MMCX
MMCX
Auxiliary Antenna Connector Type:
MMCX
MMCX
Frequency Error (over temp range):
+/- 1.5ppm
+/- 3.0ppm
5.0V ±5%
3.3V ±5%
5.0V ±5%
3.3V ±5%
130mA@5v
240mA@5v
240mA@3v3 & 117mA@5v
360mA@3v3 & 275mA@5v
530mA@3v3 & 440mA@5v
Frequency Range
Antenna Impedance:
50Ω
Supply Rails
DC Supply #1
DC Supply #2
Current Consumption (nom @ +25° C)
+10dBm output power
+20dBm output power
+27dBm output power
+30dBm output power
RX
Current Consumption (maximum)
+5.0v
+3.3v
I/O Connector
Operating Temperature
Humidity
Storage Temperature
Dimensions
Modulation technique
Bandwidth
Page 28
820mA@5v
<1mA @ 5.0V
270mA @3.3V
<1mA @ 5.0V
270mA @3.3V
1.35A
375mA
Oupiin 2216-40-G-10-DPU
760mA
540mA
Oupiin 2216-40-G-10-DPU
-40 to +75°C
Duty cycle limits apply.
5 – 95% non-condensing
-40 to +75°C
Duty cycle limits apply.
5 – 95% non-condensing
-40°C to +85°C
-40°C to +85°C
80mm x 55mm x 8mm (includ- 80mm x 55mm x 8mm (including connectors)
ing connectors)
2 Level GFSK
2 Level GFSK
382kHz
382kHz
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Appendix – FCC Approved Antennas
Part Number
Description
Yagi Antennas
BMY890K
10dBd, 900MHz Yagi Directional Antenna
Bluewave, Marathon Series
BMY890G
6.5dBd, 900 MHz Yagi Directional Antenna
Bluewave, Marathon Series
BGY890K
10dBd, 900 MHz Yagi Directional Antenna
Bluewave, Gaurdian Series
BGY890G
6.5dBd, 900MHz Yagi Directional Antenna
Bluewave, Gaurdian Series
BXY24XI
6dBd, 2,4GHz Yagi Directional Antenna
Bluewave, Sentinel Series
BXY24XK
8dBd, 2,4GHz Yagi Directional Antenna
Bluewave, Sentinel Series
BXY24XM
10dBd, 2,4GHz Yagi Directional Antenna
Bluewave, Sentinel Series
Omni Antennas
BMO902J
9dBd, 900MHz Omni Directional Antenna
Bluewave, Marathon Series
BMO902H
7dBd, 900 MHz Omni Directional Antenna
Bluewave, Marathon Series
BMO902G
6dBd, 900 MHz Omni Directional Antenna
Bluewave, Marathon Series
BGO902G
6dBd, 900MHz Omni Directional Antenna
Bluewave, Gaurdian Series
BXO24XD
1dBd, 2.4GHz Omni Directional Antenna
Bluewave, Sentinel Series
BXO24XG
4dBd, 2.4GHz Omni Directional Antenna
Bluewave, Sentinel Series
BXO24XJ
7dBd, 2.4GHz Omni Directional Antenna
Bluewave, Sentinel Series
BXO24XM
10dBd, 2.4GHz Omni Directional Antenna
Bluewave, Sentinel Series
ANT2G4WHIP
0dBd, 2.4GHz Omni Directional Antenna Trio
Datacom, Whip Series
Panel Antennas
BXL24XM
10dBd, 2.4GHz Panel Directional Antenna
Bluewave, Sentinel Series
WARNING
Changes or modifications not expressly approved by Trio Datacom
could void the user’s authority to operate the equipment. Fixed
antennas require installation preventing end-users from replacing
them with non-approved antennas. Antennas not listed in the
above table must be tested to comply with FCC Section 15.203
(unique antenna connectors) and Section 15.247 (emissions).
Please contact Trio Datacom Inc. if you need more information.
Page 29
© Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
HEAD OFFICE
41 Aster Avenue,
Victoria, Australia 3201
Phone +61 3 8773 0100 Fax +61 3 9775 0505
sales@triodatacom.com
www.triodatacom.com
NORTH AMERICA
48 Steacie Drive, Kanata, ON Canada K2K 2A9
Tel: (613) 287 0786
Fax: (613) 591 1022
Toll Free: (866) 844 8746 (TRIO)
sales-na@triodatacom.com
www.triodatacom.com
Innovative and sophisticated
digital communications
designs products and solutions
Page 30
Information subject to change without notice.
© Copyright 2008 Trio DataCom Pty Ltd. All rights reserved.
Issue: 08-08
© Copyright 2008 Trio DataCom Pty. Ltd.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2008:08:29 09:58:01+12:00
Create Date                     : 2008:08:08 14:02:00Z
Trapped                         : False
Creator                         : Adobe InDesign CS (3.0.1)
Producer                        : Adobe PDF Library 6.0
Page Count                      : 16
About                           : uuid:66c1ef43-7f3f-4923-b11a-82965c85a981
Creation Date                   : 2008:08:08 14:02:00Z
Mod Date                        : 2008:08:29 09:58:01+12:00
Metadata Date                   : 2008:08:29 09:58:01+12:00
Creator Tool                    : Adobe InDesign CS (3.0.1)
Rendition Class                 : proof:pdf
Derived From Instance ID        : ed43a06c-9e15-11dc-87f1-f20735476642
Derived From Document ID        : adobe:docid:indd:ed43a06b-9e15-11dc-87f1-f20735476642
Document ID                     : adobe:docid:indd:a9a282a5-64de-11dd-a1b1-bdfbd4218e86
Format                          : application/pdf
Title                           : O Series User Manual 08-08.indd
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NI8OM240

Navigation menu