Siemens Canada Siemens Milltronics Process Instruments IQ160 Industrial Fluid Level Sensor Transmitter User Manual Users manual and operational description
Siemens Canada Ltd. - Siemens Milltronics Process Industrial Fluid Level Sensor Transmitter Users manual and operational description
Contents
- 1. Users manual and operational description
- 2. FCC Information to Users added to the manual
Users manual and operational description
33455500 Rev 1.0 T hank you for purchasing Milltronics products. We endeavour to design equipment that is simple to use and reliable in its operation, with the aim of satisfying our customers' needs. Milltronics has been designing and manufacturing process equipment since 1954. Our fields of expertise include ultrasonic and capacitance level measurement, in-line weighing of dry bulk solids and motion sensing. Milltronics is established world wide through associate offices and representatives. Our network is continually being refined to provide our customers with first rate sales information, engineering assistance and after sales support. For more details on our products and service, please contact us and we will provide you with a listing of the offices or representatives nearest you. _ TABLE OF CONTENTS GENERAL INFORMATION About This Manual .................................................................................................5 About IQ Radar 160...............................................................................................6 SPECIFICATIONS IQ Radar 160 ...........................................................................................................7 INSTALLATION Location ....................................................................................................................9 Dimensions............................................................................................................10 Mounting................................................................................................................11 Flanged .........................................................................................................11 Extension Requirements...........................................................................12 Rod Assembly .............................................................................................13 Interconnection ..................................................................................................14 Terminal Block Layout ...............................................................................14 Wiring.............................................................................................................15 START UP Overview ................................................................................................................17 Display and Keypad ............................................................................................19 Local Operation....................................................................................................20 Run Display ..................................................................................................20 Run Keypad .................................................................................................21 Program Display ..........................................................................................22 Program Keypad.........................................................................................23 Local Programming ....................................................................................24 OPERATION Overview ................................................................................................................27 Transceiver ............................................................................................................28 Blanking .................................................................................................................29 Loss of Echo .........................................................................................................30 Analog Output ......................................................................................................31 Programming ...............................................................................................31 Run.................................................................................................................31 Fail-safe.........................................................................................................32 Run / Program ......................................................................................................32 Application Example ...........................................................................................33 PARAMETER DESCRIPTION ...........................................................................................35 TROUBLESHOOTING ........................................................................................................41 MAINTENANCE ...................................................................................................................43 APPENDICES Alphabetical Parameter List ..............................................................................45 Programming Chart ...........................................................................................46 PL-550 PL-550 _ GENERAL INFORMATION It is essential that this manual be referred to for proper installation and operation of your IQ Radar 160. Installation gives you step-by-step direction for the installation and interconnection of your IQ Radar 160. Start-up instructs you in how to operate the keypad, program the unit and read the display. Operation describes the operation of the IQ Radar 160, detailing the interoperation of the salient features. Applications looks at the IQ Radar 160 from a practical point of view, using a typical application example. Parameters lists the parameters available to you, with a description of their function and use. You are urged to read this section to familiarize yourself with the parameters available to you and get your IQ Radar 160 working to its fullest. Troubleshooting tabulates symptoms, causes and actions to common installation and application problems that you might encounter. Hopefully you will never have to read this section, but know it’s there to help you. Appendices what manual would be complete without one! Ours is an alphabetical cross-reference of the parameters and their numbers, and a record sheet for jotting down parameter values. Handy indeed! PL-550 GENERALLINFO. _ ABOUT THIS MANUAL GENERAL INFO. ABOUT IQ RADAR 160 The IQ Radar 160 is to be used only in the manner outlined in this manual. IQ Radar 160 is a versatile process material level monitoring instrument. Material level measurement is achieved using advanced pulse radar techniques. The unit consists of an electronic component coupled to the antenna. IQ Radar 160 Features: ✓ ANSI, DIN flange or sanitary tri-clamp mounting ✓ corrosion-resistant construction, aluminum enclosure with stainless steel and Teflon® wetted parts ✓ local display ✓ infrared keypad and Dolphin-compatible IQ Radar 160 Applications: ✓ liquids, slurries ✓ process temperatures up to 200°C ✓ vacuum and pressurized vessels IQ Radar 160 Approvals and Certificates ✓ safety and radio ® Teflon is a registered trademark of Du Pont. PL-550 _ SPECIFICATIONS IQ RADAR 160 100/115/200/230 ±15% V ac*, 50/60 Hz, 15 VA *factory set – see device nameplate Power: Interface: analog output: display (local): Performance: frequency: accuracy: range: repeatability: fail-safe: Mechanical: enclosure (electronic): construction: conduit: ingress protection: resonator: flange: antenna: type: construction: weight: PL-550 5.8 GHz > ±0.3% of range (1 to 10 m) 10 m 30 µW averag e mA programmable high, low or hold aluminum , epoxy coated 2 x 1/2" NPT or PG 16 entry Type 6 / NEMA 6 / IP-67 plated aluminum 316 stainless steel, 150 psi ANSI, DIN PN16, 3" sanitary tri-clamp dielectric rod Teflon® 6.5 kg (14.3 lb) with 2"/150 psi ANSI flange, weight will vary with flange size and rating SPECIFICATIONS _ Dolphin/RS-485 link: programmer link: optically-isolated 0/4-20 mA into 750 Ω max, 0.02 mA resolution refer to Dolphin product specification infrared receiver (refer to Pro gra mme r specification below) backlight , alphanumeric and multi -graphic liquid crystal for readout and entry Environmental: location: altitude: ambient temperature: relative humidity: SPECIFICATIONS _ installation category: pollution degree: Process: material dielectric: temperature: pressure (vessel): Programmer (remote keypad): enclosure: ambient temperature: interface: power: weight: indoor/outdoor 2000 m max -20 to 60° C (-4 to 140° F) suitable for outdoor (Type 6/NEMA 6/IP 67 enclosure) II εr > 4 -40 to 200°C (-40 to 392°F) -100 kPa to 1000 kPa (-1 to 10 bar or -10 to 150 psi) general purpose 67 mm w x 100 mm h x 25 mm d (2.6" w x 4" h x 1" d) -20 to 50° C (-5 to 122° F) proprietary infrared pulse signal 9V battery (ANSI/NEDA 1604, PP3 or equivalent 150 g (0.3 lb) Approvals (refer to device nameplate ) : safety: CSA NRTL/C, CE radio: BAPT, Tr ansport Canada PL-550 _ INSTALLATION LOCATION Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. Do not mount in direct sunlight without the use of a sun shield. INSTALLATION _ PL-550 DIMENSIONS 50 m m (2.0") 136 mm (5.4") 75 mm (3.0") 211 mm (8.3") enclosure/ electronics 41 mm (1.6") 245 mm (9.6") 183 mm (7.2") antenna (resonator) INSTALLATION _ flange or tri-clamp antenna (rod) 412 mm ◊ (16.3") * Flange thickness varies with size and rating. 25mm (1") nominal. Check appropriate standard. ◊ Standard length, 50 and 100 mm (2” and 4") extensions available. PL-550 10 _ MOUNTING FLANGED 1/2" NPT or PG 16 conduit entry wiring access cover supplied ANSI, DIN flange or sanitary tri-clamp customer flanged standpipe to suit tank minimum diameter 2" / DIN 50 rod transition For 2" or 3" / DIN 50 or DIN 80, the straight/taper transition of the rod should extend past the standpipe/vessel opening. Add extensions as required. For larger diameter standpipes, refer to Extension Requirements. PL-550 11 INSTALLATION _ standpipe/vessel juncture INSTALLATION _ MOUNTING (continued) EXTENSION REQUIREMENTS PL-550 12 _ MOUNTING (continued) ROD ASSEMBLY INSTALLATION _ 50 mm 100 mm extensions standard rod PL-550 13 INTERCONNECTION INSTALLATION _ TERMINAL BLOCK LAYOUT All field wiring must have insulation suitable for at least 250 V. – mA wiring, 14 – 20 AWG, copper wire, shielded – RS-485, 14 – 20 AWG, copper wire, shielded – Line, 12 – 14 AWG, copper wire – Recommended torque on clamping screws, 0.5 – 0.6 Nm PL-550 14 _ WIRING 4-20 mA, to instrumentation RS-485, to host device V supply, see nameplate The equipment must be protected by a 15 A fuse or circuit breaker in the building installation. A circuit breaker or switch in the building installation, marked as the disconnect switch, shall be in close proximity to the equipment and within easy reach of the operator. PL-550 15 INSTALLATION _ Ground shields at one end only. PL-550 16 INSTALLATION _ _ START UP OVERVIEW The IQ Radar 160 has two modes of operation: run and program. When the unit is powered, after installation procedures have been completed, it is programmed to start up in the run mode, to detect the distance from the antenna flange to the target in meters. typical display The unit can be placed into the program mode at any time; to alter a number of program parameters in order to better suit the application or user’s preferences. Programming can be carried out locally via the hand programmer or remotely via the optional Dolphin/RS-485 interface. START UP _ RS-485 hand programmer PL-550 17 The first step in programming is to ensure that all parameters are at their factory setting. The quickest way is to perform a master reset, P999. For a Quick Start, P001 to P007 are the key parameters requiring entry. They set: - mode of measurement - process material - antenna configuration - measurement response - units - empty distance - span There are a number of other program parameters that can be changed subsequently or during another programming session. Refer to Parameter Description for a list of the parameters available. START UP When programming has been completed, the IQ Radar 160 can be put into run by pressing or exiting Dolphin. PL-550 18 _ DISPLAY AND KEYPAD START UP _ PL-550 19 LOCAL OPERATION START UP RUN DISPLAY ➀ reading ➁ units ➂ reading questionable, appears during fail-safe operation ➃ auxiliary reading ➄ ➅ = normal operation = fail-safe operation bar graph representation of material level, 0 to 100% of span PL-550 20 _ LOCAL OPERATION (continued) RUN KEYPAD In the run mode, the following programmer keys perform the identified functions. Auxiliary Reading Keys Function Keys Key mA Auxiliary readings “mA Output Value” “Rate of Change” (in Units/minute) “Fail-safe Time Left” (in percent) PX X X “Material Level” “Distance” initiate and complete program mode access PL-550 toggle between Units and % 21 START UP _ LOCAL OPERATION (continued) PROGRAM DISPLAY parameter type (measurement or mA output) parameter value units parameter number START UP ➀ ➁ ➂ ➃ PL-550 22 _ LOCAL OPERATION (continued) PROGRAM KEYPAD Numeric Keys Function Keys Key to values decimal point PX X X negative value clear value enter the displayed value parameter scroll-up parameter scroll-down end program session and enable run mode PL-550 23 START UP _ LOCAL OPERATION (continued) Legend Press the associated key on programmer: Programmer key: Display shown on IQ Radar 160: LOCAL PROGRAMMING To Access Program run mode Initial program starts at P000 To Access a Parameter scroll Scroll up or down START UP direct e.g. P000 accessed index parameter field mA e.g. P005 accessed PL-550 24 _ LOCAL OPERATION (continued) Local Programming (continued) To Change a Parameter Value: Security must be disabled! change Select parameter e.g. P001 = 3 e.g. P001 = 1 clear PL-550 e.g. P001 = 1 25 START UP _ e.g. field entry = 2 LOCAL OPERATION (continued) Local Programming (continued) reset e.g. P001 = 1 Reset to factory value P001 = 3 To Access Run: START UP from program exit and return to run PL-550 26 _ OPERATION OVERVIEW IQ Radar 160 is a process material level measuring device using advanced pulse radar technology. The device emits a series of radar pulses and analyses the reflection to calculate the material level. The device consists of an enclosed electronic component, mounted to a flanged antenna component. The electronic component generates a 5.8 GHz radar signal which is directed to the antenna, a Teflon ® dielectric rod coupled to the core of the device’s mounting flange. The radar signal is emitted axially from the antenna and propagates along this axis in a defined conical beam decreasing in strength at a rate inversely proportional to the square of the distance. Radar reflection is based on the dielectric constant and planar property of the materials encountered and thus radar is very suitable for still (non-agitated) liquids and slurries. Radar is immune to temperature and atmospheric conditions and variations in the vessel. In an ideal application, echoes from stratified vapours are either non-existent, or minimal compared to major echoes from the process material. Where atmospheric conditions are such that dielectric constants and stratifications are of significance, their echoes can compete with the desired reflection from the process material, making the application troublesome. The series of echoes from the pulses transmitted are sensed by the antenna during the receive period of the electronics. The echoes are stored as a profile of the activity in the vessel. The profile is analysed and the distance of the material surface to the radar antenna is determined. This distance is used as a basis for display of material level and mA output. OPERATION _ PL-550 27 TRANSCEIVER The IQ Radar 160 transceiver operates under 1 of 5 sets of preset conditions (P003), summarized as follows: parameter value measurement response echo verification filter fail-safe timer 0.1 m/min slow on on 100 1 m/min • on on 10 10 m/min • on on 100 m/min • off on 0.1 1000 m/min fast off off When the echoes are received, the relevant echo extraction technique (P820) is applied to determine the true material echo. OPERATION The measurement response limits the maximum rate at which the display and analog output respond to changes in measurement. It is of concern especially where liquid surfaces are in agitation or falls into the radar path during filling. PL-550 28 _ BLANKING Near blanking (P800) is used to ignore the zone in front of the antenna where false echoes (e.g. ladder rung) appear as an echo during the receive cycle. This is usually indicated by an incorrect high level reading and can be overcome by increasing the near blanking from its factory set value. Far end blanking is a feature that ignores the zone below the zero or empty level where false echoes can appear at levels that interfere with the processing of the true echo. true echo (level) false echo false echo Typical receiver signal end of transmit level P800 near blanking far end blanking empty distance to antenna P006 range extension (P801) as % P006 range Typical receiver signal In applications where the zero level is above the bottom of the vessel and it is desired to monitor the zone below the normal zero, range extension (P801) can be used to extend the range into the far end blanking. Range extension is entered as a percentage of P006. As range extension reduces the protection afforded by the far end blanking, it should be used judiciously. Avoid excessive range extension as this can reduce the measurement’s reliability and accuracy. Range extension is factory set for 20% of P006. If it is found that false echoes are appearing ahead of the blanking zone, P006 should be reduced accordingly. 29 OPERATION _ PL-550 LOSS OF ECHO A loss of echo occurs when the IQ Radar 160 deems that the calculated measurement is unreliable, i.e. the confidence (P805) is less than the threshold (P804). This can be due to such circumstances as high level of electrical noise or poor grounding. Refer to Troubleshooting. If the condition persists for a time beyond the limit as set by the fail-safe timer (P070), the confidence icon changes from full to partial and the reading and mA output are immediately forced to the fail-safe default (P071). OPERATION Upon receiving a reliable echo, the loss of echo condition is aborted (icon returns to full) and the reading and mA output return to the present level immediately. PL-550 30 _ ANALOG OUTPUT The IQ Radar 160 can be programmed to provide an analog output (P200) of 0 to 20 or 4 to 20 mA, and for proportional or inverse span. Programming Upon entering the Program mode, the analog output level holds its prior value. Run The analog output responds in the following manner: 0/4 – 20 mA (P200 = 1 or 2) 20 – 0/4 mA (P200 = 3 or 4) Level (P001=1) Space (P001=2) Distance (P001=3) PL-550 31 OPERATION _ *reference value only. mA level limited by near blanking. 0 and 100% are percentage of full scale reading (m, cm, mm, ft, in) Fail-safe When the fail-safe timer (P070) expires, the mA output responds as follows: Fail-safe Mode (071) Status 0/4 - 20 20 - 0/4 high 22 0/2 low 0/2 22 hold hold hold RUN / PROGRAM When the IQ Radar 160 changes from run to program, the transceiver stops operating and the unit no longer responds to the process. The last measurement is stored and the associated reading and mA output are held. As a courtesy, the unit reverts to the parameter last addressed during the previous program session. OPERATION Upon return to run, the transceiver resumes operation. The reading and mA output default to the last measurement taken. The reading and associated outputs migrate to the current process level at a rate controlled by the measurement response (P003). PL-550 32 _ APPLICATION EXAMPLE The minimum distance from the antenna face to the target is limited by the near blanking, P800. The application is to obtain a level measurement and corresponding 4-20 mA output proportional to material levels in a chemical tank. The antenna flange is 5 m from the tank bottom. The empty level is 0 m (bottom) and the full level (span) is 4.5 m from the bottom. The maximum rate of filling or emptying is about 1 m/min. In the event of a loss of echo, the IQ Radar 160 is to go into fail-safe low after 2 minutes. Empty (P006) Span (P007) master reset enter ‘1’ enter ‘1’ enter ‘2’ enter ‘240’ enter ‘1’ enter ‘5’ enter ‘4.5’ enter ‘2’ enter ‘2’ mode of measurement = level material = liquid measurement response = 1m/min. antenna = dielectric rod, standard length units = metres empty distance = 5 m span = 4.5 m fail-safe timer = 2 min. fail-safe = low press run to start normal operation reset: P999 program: P001 P002 P003 P004 P005 P006 P007 P070 P071 run: OPERATION _ PL-550 33 PL-550 34 OPERATION _ P000 lock Locks out the ability to change parameter values P001 through P999. The program mode is still active, but restricted to viewing only. The lock is enabled if P000 value is other than 1954. entry: P001 1954 = unlocked 1954 = locked opera tion Determines the mode of measurement. entry: 1= level; material level referenced to empty distance (P006) 2= space; space to material level referenced from zero span 3= distance; distance to target referenced from the flange face Level (P001 = 1) PL-550 Space (P001 = 2) 35 Distance (P001 = 3) PARAMETER DESCRIPTION _ PARAMETER DESCRIPTION PARAMETER DESCRIPTION P002 material Optimizes measurement reliability for target type. entry: 1 = liquids, fluids or flat surfaces P003 measurement response Collectively sets a number of operating parameters that determine the maximum rate of change in target range that the reading and mA output can keep up to. If IQ Radar 160 cannot keep up with the rate of level change, select a faster rate. If the reading bounces around an average value, select a slower rate. In general, reliability is traded for speed. Noisy applications or those with agitators tend to be more manageable at slower response rates, as these make use of filtering, echo verification and longer failsafe delay. Select P003 for a measurement response just faster than the greater of the maximum filling or emptying rate. echo verification: discriminates between agitator blades in motion or spurious noise, and the target surface (true echo). filter: discriminates between false echoes from constant aco ustical or electrical noise and the target surface. fail-safe timer: establishes the period from the time a loss of echo starts until the fail-safe default (P071) is effected. The P003 preset timer value can be overridden by P070. entry: measurement response echo verification filter f-s timer (P070) slow on on 100 2 = 1 m/min • on on 10 3 = 10 m/min • on on 4 = 102 m/min • off on 0.1 5 = 1020 m/min fast off off 1 = 0.1 m/min PL-550 36 _ P004 antenna entry: P005 240 241 242 243 dielectric rod rod + 50 mm extension rod + 100 mm extension rod + 150 mm extension (50 + 100mm) units Determines the units for programming and measurement. entry: P006 = metres = centimetres = millimetres = feet = inches empty Distance from flange face to empty level or maximum target range. P007 span Distance from empty (P006) to full/100% level or minimum target range. P070 fail-safe timer The amount of time delay, in minutes, before going into fail-saf e mode. P071 fail-safe material level Selects the default measurement in the event that the fail-safe timer expires. entry: P200 1 = high; maximum span value 2 = low; minimum span value 3 = hold; hold current value mA range Enables the mA output function by selecting the range and relationship to span. Refer to Functional / mA output. entry: PL-550 0 to 20 4 to 20 20 to 0 20 to 4 mA mA mA mA 37 PARAMETER DESCRIPTION _ Identifies antenna configuration. PARAMETER DESCRIPTION P341 run time View the accumulated number of days the IQ Radar 160 has been operating. P652 offset correction An offset value can be applied to the reading as a correction to the measurement. values: P800 -999 to 9999 near blanking Sets the amount of blanking as measured from the flange face and extending into the measurement range. Refer to Operation / Blanking. enter value in units of P005. P801 range extension Sets the amount of range extension as measured from the empty distance (P006) and extending into the far end blanking. Refer to Operation / Blanking. enter as a % of P006, the distance below empty not blanked. P804 confidence threshold The minimum echo confidence in dB that the echo must meet in order to prevent a loss of echo condition and the expiration of the fail-safe timer (P070). enter value in the range of 0 to 99. P805 echo confidence A measure of echo reliability. P806 echo strength The absolute strength of the selected echo, in dB above 1 µV rms. PL-550 38 _ P820 algorithm entry: P830 1 = best of first and largest 2 = first echo 3 = largest echo TVT type Selects the TVT profile applied to the echo profile. entry: P900 1 = standard 2 = flat software revision Displays the EPROM software revision level. P901 memory Tests the memory. Test is initiated by scrolling to the parameter or repeated by display: P911 PASS = normal FAIL = consult Milltronics mA output value Displays the value from the previous measurement. A test value can be entered and the displayed value is transmitted to the output. Upon returning to the run mode, the parameter assumes the actual mA output level. P920 reading measurement Displays the reading measurement that the unit is programmed for in run mode (P001, operation). P921 material measurement Displays the reading measurement as though the unit were programmed to read level (P001 = 1). P922 space measurement Displays the reading measurement as though the unit were programmed to read space (P001 = 2). PL-550 39 PARAMETER DESCRIPTION _ Selects the algorithm to be applied to the echo profile in order to extract the true echo. PARAMETER DESCRIPTION P923 distance measurement Displays the reading measurement as though the unit were programmed to read distance (P001 = 3) P999 master reset Resets parameters to their factory setting initiate reset reset complete PL-550 40 _ TROUBLESHOOTING The following is a list of operating symptoms, their probable causes and the actions needed to resolve them. SYMPTOM CAUSE ACTION display reads level or target is out of range check specifications application too steamy, under these conditions range can be adversely affected. re-locate IQ Radar 160 material build-up on antenna clean increase fail-safe timer, P070 re-locate IQ Radar 160 Reading does not change, but the level does location or aiming: -poor installation -moved by material or vibration -flanging not level -standpipe not vertical relocate or re-aim IQ Radar 160 for maximum echo confidence, P805 antenna malfunction: -temperature too high -physical damage -excessive foam or skin inspect use foam deflector or stilling well or relocate IQ Radar 160 processing re-locate IQ Radar 160 wrong echo, i.e. vessel wall, or structural member check standpipe for internal burrs or welds increase blanking, P800 raise short measurement confidence threshold, P804 *refer to associated manual … continued PL-550 41 TROUBLESHOOTING _ check parameters SYMPTOM CAUSE ACTION Measurement is consistently off by a constant amount measurement offset correct using P652 Screen blank power error check nameplate rating against voltage supply TROUBLESHOOTING check power wiring or source Reading erratic echo confidence weak, liquid surface agitated, material filling refer to P805 decrease measurement response P003 enable filter, echo verification re-locate IQ Radar 160 Reading ‘EEEE’ reading too large re-program ie. empty distance P006 or span P007 Reading response slow P003 setting increase response if possible Reads correctly but occasionally reads high when vessel is not full detecting close range echo increase blanking High level reading lower than material level material is within near blanking zone decrease blanking P800 PL-550 42 _ MAINTENANCE The IQ Radar 160 requires no maintenance or cleaning; however, a program of periodic checks is advised. MAINTENANCE _ PL-550 43 PL-550 44 MAINTENANCE _ APPENDICES ALPHABETICAL PARAMETER LIST algorithm ..................................................................................................P820 antenna ..................................................................................................P004 confidence threshold ............................................................................P804 echo confidence ....................................................................................P805 echo strength..........................................................................................P806 empty........................................................................................................P006 fail-safe material level ...........................................................................P071 lock ............................................................................................................P000 long shot number* .................................................................................P841 mA output value ....................................................................................P911 mA range .................................................................................................P200 master reset ............................................................................................P999 material ....................................................................................................P002 measurement response .......................................................................P003 memory ....................................................................................................P901 near blanking ..........................................................................................P800 offset correction......................................................................................P652 operation..................................................................................................P001 range extension .....................................................................................P801 run time ....................................................................................................P341 span ..........................................................................................................P007 TVT type ..................................................................................................P830 units ..........................................................................................................P005 * accessible in Dolphin only. PL-550 45 APPENDICES _ software revision ....................................................................................P900 PROGRAMMING CHART APPENDICES PARAMETER NAME P001 Operation P002 Material P003 Measurement Response P004 Antenna P005 Units P006 Empty P007 Span P070 Fail-Safe Timer P071 Fail-Safe Material Level P200 mA Range P652 Offset Correction P800 Near Blanking P801 Range Extension P804 Confidence Threshold P820 Algorithm P830 TVT Type P841 Long-Shot Number PL-550 VALUE 46
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 1998:05:25 15:46:51 Producer : Acrobat Distiller 3.0 for Windows Modify Date : 1998:07:02 13:49:17 Page Count : 46EXIF Metadata provided by EXIF.tools