Siemens Medical Solutions Department MED EH and S WFSW Footswitches for RC of medical x-ray-systems User Manual Artis Footswitch ADD

Siemens Medical Solutions, Department MED EH&S; Footswitches for RC of medical x-ray-systems Artis Footswitch ADD

Users Manual

Download: Siemens Medical Solutions Department MED EH and S WFSW Footswitches for RC of medical x-ray-systems User Manual Artis Footswitch ADD
Mirror Download [FCC.gov]Siemens Medical Solutions Department MED EH and S WFSW Footswitches for RC of medical x-ray-systems User Manual Artis Footswitch ADD
Document ID602162
Application IDWSZSiDtJgfZ8gmP2vwxldQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize6.92kB (86463 bits)
Date Submitted2005-11-14 00:00:00
Date Available2005-11-14 00:00:00
Creation Date2005-07-05 16:49:40
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2005-07-05 16:49:40
Document TitleArtis_Footswitch_ADD.fm
Document CreatorPScript5.dll Version 5.2.2

Addendum
AXIOM Artis
Wireless Footswitch Artis
Important information
The Wireless Footswitch has the same functions as the standard footswitch
without being connected by cable. The functions are activated via an RF transmitter.
The immanent advantages are easier cleaning and no tripping over cables.
The Wireless Footswitch shall be operated in close vicinity to the patient table
only and with full visibility to the patient on the table.
Caution
Unnecessary Dose
hm_um_CautionDontXrayIfNotInVis
ibility
X-ray release may be possible from remote locations
u Do not release X-ray mistakenly if not in viewing distance to the patient and
close to an emergency button
The batteries shall always be sufficiently charged.
Caution
Discontinuation of interventional treatment
hm_um_MobileDockingStation
Batteries of Wireless Footswitch may be flat
u Make sure the batteries are charged prior to starting an examination.
u In case of empty batteries use Charging Station to continue treatment.
The Wireless Footswitch can interfere with life supporting devices.
AXIOM Artis
Draft
1 /4
Wireless Footswitch Artis
Caution
Footswitch too close to a life supporting device
hm_um_WirelessFSWSepDist
Interference with life supporting device and possible malfunctioning
u Make sure to keep a separation distance of > 7 cm between the Wireless
Footswitch and a life supporting device
Changes or modifications not expressly approved by the party responsible for
compliance could void the user´s authority to operate the equipment.
The Wireless Footswitch may be interfered with by other equipment, including
portable and mobile RF communication equipment, even if such equipment
meets the applicable emissions requirements.
The Wireless Footswitch must emit electromagnetic energy in order to perform
its intended function. Nearby electronic equipment may be affected.
Operation
Footswitches
There are two monoplane versions with 4 pedal functions and a biplane version
with 8 pedal functions. The functions of the pedals can be configured by Siemens
Service to your preference. Please see the suggested assignment in the Operator Manual Artis.
The Wireless Footswitches are marked with a colored sign of different shape to
avoid a mix up for installations with a multitude of Wireless Footswitches. The
same marks are attached to the respective table and room during installation.
Monoplane Wireless Footswitch (example)
2 /4
Draft
Addendum
Wireless Footswitch Artis
Biplane Wireless Footswitch
The footswitch is active in a range of appr. 5 m around the table/stand, where the
receiver is mounted. If the footswitch is in a wider range of the table, it may lose
contact with the receiver and will then turn into an inactive mode.
There are 3 LEDs showing the status of the footswitch.
LED on: Footswitch is on and is in active mode.
LED off: Footswitch is inactive.
– It is too far away from the table
– The Artis system is switched off
– The batteries are completely discharged
– The Footswitch is in “sleep mode”. Press a pedal swiftly to activate it
again.
LED on: Any footswitch pedal is being pressed.
LED off: battery sufficiently charged, footswitch not connected to the Charging
Station,
LED flashing yellow: battery needs charging, remaining capacity < 4h.
LED on yellow: footswitch connected to Charging Station and batteries are being
charged.
LED on green: footswitch connected to Charging Station and batteries are fully
charged.
This symbol marks an RF transmitting component.
Two examples of colored signs of different shape to mark the footswitch to an
Artis system.
Charging Station
The Charging Station is connected to the Wireless Footswitch for charging the
batteries. It is recommended to connect the Charging Station after deployment
each day.
AXIOM Artis
Draft
3 /4
Wireless Footswitch Artis
Charging Station
If the Wireless Footswitch needs charging during a patient procedure, simply
connect it to the Charging Station. The cable length of 7 m allows charging during
the procedure.
Never use another charging device than the Charging Station delivered with the
Wireless Footswitch.
Usage of another charging device may cause severe damage to the Wireless
Footswitch or may lead to hazards for the patients when the Wireless Footswitch
is recharged during operation.
Exchange of batteries
The batteries of the Wireless Footswitch must be exchanged once a year by authorized and trained staff. Please call Siemens Service. Unauthorized exchange
may cause severe damage.
Technical Data
Active range
Approximately 5 m around the receiver mounted to the table/stand.
Charging time
Approx. 6 h
Operating time with full
batteries
Approx. 60 h
Frequency range
2402 MHz - 2480 MHz
Modulation
GFSK
RF Power
0 dBm
RF emissions CISPR 11
Compliance: Group 2
4 /4
Draft
Addendum

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4b30d7f1-98f7-4c35-9faf-dbd979ec90dd
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2005:07:05 16:49:40+02:00
Create Date                     : 2005:07:05 16:49:40+02:00
Document ID                     : uuid:5b3f0aa3-318b-46f1-9c77-6ea84866275b
Format                          : application/pdf
Title                           : Artis_Footswitch_ADD.fm
Creator                         : PScript5.dll Version 5.2.2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S5H-WFSW

Navigation menu