Siemens MOBYI-SLG40SN Tag Reader System User Manual MOBY I e
Siemens AG Tag Reader System MOBY I e
Siemens >
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
Users Manual Part 3
Read/Write Devices MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 5-1 Read/Write Devices 5.1 Introduction Application area The read/write devices (i.e., SLGs) provide inductive communication with the mobile data memories (i.e., MDSs) and the serial link to the interfaces (i.e., ASMs). Various SLG models – for short, medium and long distances to the MDS – are available to meet customer requirements. Layout and functions The SLG executes commands received from the interface. These commands for reading and writing data are converted via a modulator/demodulator circuit. Communication between MDS and SLG takes place via inductive alternating fields. The amount of data which can be transferred between SLG and MDS depends on the factors listed below. S The speed at which the MDS moves through the transmission window of the SLG S The length of the transmission window S The type of MDS (i.e., RAM, FRAM, EEPROM) Overview table Table 5-1 Overview table of the SLG SLG Type Operating Distance Sa (Depending on MDS) Limit Distance Sg SLG 40 2 to 8 mm 10 mm –25 to +70° C ∅ 30 x 54 (head) IP65 SLG 40-S 2 to 6 mm 8 mm –25 to +70° C ∅ 18 x 30 (head) IP65 SLG 41/41-S 0 to 15 mm 25 mm –25 to +70° C 120 x 40 x 40 IP65 SLG 41C/41CC 0 to 15 mm 25 mm –25 to +70° C 55 x 75 x 30 IP67 SLG 42 0 to 55 mm 70 mm –25 to +70° C 75 x 40 x 75 IP65 SLG 43 0 to 100 mm 150 mm –25 to +70° C 238 x 40 x 80 IP65 SLG 44 100 to 800 mm 1000 mm –25 to +70° C 238 x 40 x 80 IP63 5-2 Temperature Range (During Operation) Dimensions (WxHxD) in mm Protection Rating MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 Read/Write Devices 5.2 SLG 40 Application area The SLG 40 is extremely suited for use on small assembly lines. The short installation distance between several SLG 40 antennas is a special feature. With the 2 included screw nuts, the antenna head can be positioned with extreme precision for each application. Figure 5-1 Read/write device SLG 40 Ordering data Table 5-2 Ordering data for SLG 40 Read/write device SLG 40 up to 10 mm (low power), incl. screw nuts Accessories: SLG plug connector and stub lines Mounting clamp Technical data Table 5-3 6GT2 001-0EA10 See chapter 3.10 3SX6 284 Technical data of SLG 40 Inductive interface to MDS Data transmission speed Read/write distance SLG to MDS (max.) Transmission frequency S Power S Data Serial interface to ASM Transmission speed Line length, ASM to SLG (max.) at 24 V DC 19200 baud 10 mm (see field data table) 134 kHz 1.81 MHz 6-pin SLG plug connector in acc. w. DIN 43651 19200 baud, RS 422 360 m Supply voltage (via serial interface) Nominal value Permissible range Current consumption Idle/operation 24 V DC 20 to 30 V DC MTBF 2 x 106 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 25 mA/90 mA 5-3 Read/Write Devices Table 5-3 Technical data of SLG 40 Housing Dimensions (in mm) For antenna head (∅ x threading x L) For electronics w/o plug (WxHxD) Color Antenna SLG housing Material Antenna SLG housing Plug connection Protection rating Antenna and SLG housing Shock Vibration Mounting of SLG Turning moment (at room temperature) Ambient temperature During operation During transportation and storage Weight (approx.) Certifications Field data IP65 50 g 20 g 4 M5 screws 2 Nm –25° to +70° C –40° to +85° C 215 g EN 300 330 FCC Part 15 UL/CSA Applicable for MDS 402/401 Table 5-4 FCC information M30 x 1.5 x 54 125 x 40 x 75 Anthracite with orange head Ergo-gray “Crastin” Polyamide 12 DIN 43651 Field data of SLG 40 Operating distance (Sa) Limit distance (Sg) 2 to 8 mm 10 mm Median deviation (Ld) Minimum distance from SLG to SLG (D) 18 mm (+ 9 mm from middle) Da 50 mm Db 80 mm Made in Germany SIEMENS MOBY I SLG 40 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment: Such modifications could void the user’s authority to operate the equipment. 5-4 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 Read/Write Devices Transmission window Ld Ld sg Field at Sa = 2 mm sa Field at Sa = 8 mm View of top View of side Figure 5-2 View of the antenna Transmission window: To ensure reliable data communication, the antenna of the MDS must be positioned within this field. A diameter of Ld = 18 mm can be configured for the operating distance (2 to 8 mm). Metal-free space a = 10 mm b = 10 mm MOBY I SLG 40 Metal-free space with flush installation Note: The limit and operating distances are reduced when the metal-free space is not adhered to. Figure 5-3 Metal-free space for SLG 40 Optional mounting clamp 30 18 36 29 58 42,5 30 19,5 Figure 5-4 Mounting diagram and dimensions of SLG 40 with mounting clamp MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 5-5 Read/Write Devices Definition of distance D Da Db Da Db 50 mm 80 mm The SLG electronics can be mounted directly next to each other. Figure 5-5 Distance D for SLG 40 Dimensions (in mm) Anti-kink cable protector, flexible in all directions Minimum bending radius: 20 mm 40 5.5 Cable length 0.5 m Antenna head MOBY I Screw nuts 54 M30 115 125 Antenna side SLG 40 Top view of antenna head 21 MOBY I 65 75 36 SLG 40 Figure 5-6 5-6 Dimensional diagram of SLG 40 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 Read/Write Devices 5.3 SLG 40-S Application area The SLG 40 is extremely suited to use in small assembly lines. The short installation distance between several SLG 40-S antennas is a special feature. With the 2 included screw nuts, the antenna head can be positioned with extreme precision for each application. Figure 5-7 Ordering data Technical data Table 5-5 Read/write device SLG 40-S Ordering data for SLG 40-S Read/write device SLG 40-S up to 8 mm (low power), incl. screw nuts 6GT2 001-0EB00 SLG plug connector and stub lines See chapter 3.10 Table 5-6 Technical data of SLG 40-S Housing Dimensions (in mm) For antenna head (∅ x threading x L) M18 x 1.0 x 30 For electronics w/o plug (L xW x H) 75 x 75 x 40 Color Antenna Anthracite with orange head SLG housing Ergo-gray Antenna “Crastin” SLG housing Polyamide 12 Material Plug connection DIN 43651 Protection rating Antenna and SLG housing IP65 Shock 50 g Vibration 20 g Storage temperature –40° to +85° C Operation temperature –25° to +70° C MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 5-7 Read/Write Devices Table 5-6 Technical data of SLG 40-S Operating voltage Current consumption Field data 17 to 30 V DC Idle 25 mA Operation 90 mA Serial interface Transmission speed Max. cable length (cf. chap. 3.10.1; standard cable) MTBF Transmission frequency RS 422 19200 baud 360 m S Power S Data 134 kHz Mounting of SLG 4 M5 screws Turning moment (at room temperature) Mounting of SLG head (included) 2 Nm 2 nuts (M18 x 1.0) Weight (approx.) Certifications 200 g EN 300 330 FCC Part 15 UL/CSA 2 x 106 1.81 MHz Applicable for MDS 401/402 Table 5-7 Field data of SLG 40-S Operating distance (Sa) 2 to 6 mm Limit distance (Sg) Diameter of transmission window (Ld) Median deviation Minimum distance from SLG to SLG (D) 8 mm 9 mm 4.5 mm from middle Da 50 mm Db FCC information 80 mm Made in Germany SIEMENS MOBY I SLG 40S THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment: Such modifications could void the user’s authority to operate the equipment. 5-8 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 Read/Write Devices Transmission window Ld Ld sg Field at Sa = 2 mm sa Field at Sa = 8 mm View of top View of side Figure 5-8 View of the antenna Transmission window: To ensure reliable data communication, the antenna of the MDS must be positioned within this field. Metal-free space a = 10 mm b = 10 mm MOBY I SLG 40-S Metal-free space with flush installation Note: The limit and operating distances are reduced when the metal-free space is not adhered to. Figure 5-9 Metal-free space for SLG 40-S Definition of distance D Da Db Da Db 50 mm 80 mm The SLG electronics can be mounted directly next to each other. Figure 5-10 Distance D for SLG 40-S MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618 5-9 Read/Write Devices Dimensions (in mm) Anti-kink cable protector, flexible in all directions 50 Minimum bending radius: 20 mm Cable length 0.5 m Antenna head 75 65 Screw nuts 30 25 M18 Fine threading Pitch 1.0 18 5.5 75 Antenna side MOBY I SLG 40-S 24 Top view of antenna head Figure 5-11 5-10 Dimensional diagram of SLG 40-S MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A8-7618
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Producer : AFPL Ghostscript 8.0 Create Date : 2003:12:15 10:28:59 Modify Date : 2003:12:16 14:55:42+01:00 Title : MOBY_I_e.pdf Creator : PScript5.dll Version 5.2 Author : SB2851 Page Count : 10EXIF Metadata provided by EXIF.tools