Siemens MOBYI-SLG40SN Tag Reader System User Manual MOBY I e

Siemens AG Tag Reader System MOBY I e

Contents

Users Manual Part 3

Download: Siemens MOBYI-SLG40SN Tag Reader System User Manual MOBY I e
Mirror Download [FCC.gov]Siemens MOBYI-SLG40SN Tag Reader System User Manual MOBY I e
Document ID383560
Application IDNrchxKHMZ0LfW6frgpOC7Q==
Document DescriptionUsers Manual Part 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.96kB (236950 bits)
Date Submitted2003-12-22 00:00:00
Date Available2003-12-22 00:00:00
Creation Date2003-12-15 10:28:59
Producing SoftwareAFPL Ghostscript 8.0
Document Lastmod2003-12-16 14:55:42
Document TitleMOBY_I_e.pdf
Document CreatorPScript5.dll Version 5.2
Document Author: SB2851

Read/Write Devices
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
5-1
Read/Write Devices
5.1
Introduction
Application area
The read/write devices (i.e., SLGs) provide inductive communication with
the mobile data memories (i.e., MDSs) and the serial link to the interfaces
(i.e., ASMs).
Various SLG models – for short, medium and long distances to the MDS –
are available to meet customer requirements.
Layout and functions
The SLG executes commands received from the interface. These commands
for reading and writing data are converted via a modulator/demodulator circuit.
Communication between MDS and SLG takes place via inductive alternating
fields.
The amount of data which can be transferred between SLG and MDS depends on the factors listed below.
S The speed at which the MDS moves through the transmission window of
the SLG
S The length of the transmission window
S The type of MDS (i.e., RAM, FRAM, EEPROM)
Overview table
Table 5-1
Overview table of the SLG
SLG Type
Operating
Distance Sa
(Depending on
MDS)
Limit Distance Sg
SLG 40
2 to 8 mm
10 mm
–25 to +70° C
∅ 30 x 54 (head)
IP65
SLG 40-S
2 to 6 mm
8 mm
–25 to +70° C
∅ 18 x 30 (head)
IP65
SLG 41/41-S
0 to 15 mm
25 mm
–25 to +70° C
120 x 40 x 40
IP65
SLG 41C/41CC
0 to 15 mm
25 mm
–25 to +70° C
55 x 75 x 30
IP67
SLG 42
0 to 55 mm
70 mm
–25 to +70° C
75 x 40 x 75
IP65
SLG 43
0 to 100 mm
150 mm
–25 to +70° C
238 x 40 x 80
IP65
SLG 44
100 to 800 mm
1000 mm
–25 to +70° C
238 x 40 x 80
IP63
5-2
Temperature
Range
(During
Operation)
Dimensions
(WxHxD) in mm
Protection
Rating
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
Read/Write Devices
5.2
SLG 40
Application area
The SLG 40 is extremely suited for use on small assembly lines. The short
installation distance between several SLG 40 antennas is a special feature.
With the 2 included screw nuts, the antenna head can be positioned with extreme precision for each application.
Figure 5-1 Read/write device SLG 40
Ordering data
Table 5-2
Ordering data for SLG 40
Read/write device SLG 40
up to 10 mm (low power), incl. screw nuts
Accessories:
SLG plug connector and stub lines
Mounting clamp
Technical data
Table 5-3
6GT2 001-0EA10
See chapter 3.10
3SX6 284
Technical data of SLG 40
Inductive interface to MDS
Data transmission speed
Read/write distance
SLG to MDS (max.)
Transmission frequency
S Power
S Data
Serial interface to ASM
Transmission speed
Line length, ASM to SLG (max.)
at 24 V DC
19200 baud
10 mm (see field data table)
134 kHz
1.81 MHz
6-pin SLG plug connector in acc. w.
DIN 43651
19200 baud, RS 422
360 m
Supply voltage
(via serial interface)
Nominal value
Permissible range
Current consumption
Idle/operation
24 V DC
20 to 30 V DC
MTBF
2 x 106
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
25 mA/90 mA
5-3
Read/Write Devices
Table 5-3
Technical data of SLG 40
Housing
Dimensions (in mm)
For antenna head (∅ x threading x L)
For electronics w/o plug (WxHxD)
Color
Antenna
SLG housing
Material
Antenna
SLG housing
Plug connection
Protection rating
Antenna and SLG housing
Shock
Vibration
Mounting of SLG
Turning moment (at room temperature)
Ambient temperature
During operation
During transportation and storage
Weight (approx.)
Certifications
Field data
IP65
50 g
20 g
4 M5 screws
2 Nm
–25° to +70° C
–40° to +85° C
215 g
EN 300 330
FCC Part 15
UL/CSA
Applicable for MDS 402/401
Table 5-4
FCC information
M30 x 1.5 x 54
125 x 40 x 75
Anthracite with orange head
Ergo-gray
“Crastin”
Polyamide 12
DIN 43651
Field data of SLG 40
Operating distance (Sa)
Limit distance (Sg)
2 to 8 mm
10 mm
Median deviation (Ld)
Minimum distance from SLG to SLG (D)
18 mm (+ 9 mm from middle)
Da 50 mm
Db 80 mm
Made in Germany
SIEMENS MOBY I SLG 40
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Note
The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment:
Such modifications could void the user’s authority to operate the equipment.
5-4
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
Read/Write Devices
Transmission
window
Ld
Ld
sg
Field at Sa = 2 mm
sa
Field at Sa = 8 mm
View of top
View of side
Figure 5-2
View of the antenna
Transmission window:
To ensure reliable data communication, the antenna of the MDS must be
positioned within this field. A diameter of Ld = 18 mm can be configured for
the operating distance (2 to 8 mm).
Metal-free space
a = 10 mm
b = 10 mm
MOBY I
SLG 40
Metal-free space with flush
installation
Note:
The limit and operating distances
are reduced when the metal-free
space is not adhered to.
Figure 5-3
Metal-free space for SLG 40
Optional mounting
clamp
30
18
36
29
58
42,5
30
19,5
Figure 5-4
Mounting diagram and dimensions of SLG 40 with mounting clamp
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
5-5
Read/Write Devices
Definition of
distance D
Da
Db
Da
Db
50 mm
80 mm
The SLG electronics can be mounted directly
next to each other.
Figure 5-5
Distance D for SLG 40
Dimensions
(in mm)
Anti-kink cable protector, flexible
in all directions
Minimum bending
radius: 20 mm
40
5.5
Cable length 0.5 m
Antenna head
MOBY I
Screw nuts
54
M30
115 125
Antenna side
SLG 40
Top view of antenna head
21
MOBY I
65
75
36
SLG 40
Figure 5-6
5-6
Dimensional diagram of SLG 40
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
Read/Write Devices
5.3
SLG 40-S
Application area
The SLG 40 is extremely suited to use in small assembly lines. The short
installation distance between several SLG 40-S antennas is a special feature.
With the 2 included screw nuts, the antenna head can be positioned with extreme precision for each application.
Figure 5-7
Ordering data
Technical data
Table 5-5
Read/write device SLG 40-S
Ordering data for SLG 40-S
Read/write device SLG 40-S
up to 8 mm (low power), incl. screw nuts
6GT2 001-0EB00
SLG plug connector and stub lines
See chapter 3.10
Table 5-6
Technical data of SLG 40-S
Housing
Dimensions (in mm)
For antenna head (∅ x threading x L)
M18 x 1.0 x 30
For electronics w/o plug (L xW x H)
75 x 75 x 40
Color
Antenna
Anthracite with orange head
SLG housing
Ergo-gray
Antenna
“Crastin”
SLG housing
Polyamide 12
Material
Plug connection
DIN 43651
Protection rating
Antenna and SLG housing
IP65
Shock
50 g
Vibration
20 g
Storage temperature
–40° to +85° C
Operation temperature
–25° to +70° C
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
5-7
Read/Write Devices
Table 5-6
Technical data of SLG 40-S
Operating voltage
Current
consumption
Field data
17 to 30 V DC
Idle
25 mA
Operation
90 mA
Serial interface
Transmission speed
Max. cable length (cf. chap. 3.10.1; standard cable)
MTBF
Transmission frequency
RS 422
19200 baud
360 m
S Power
S Data
134 kHz
Mounting of SLG
4 M5 screws
Turning moment (at room temperature)
Mounting of SLG head (included)
2 Nm
2 nuts (M18 x 1.0)
Weight (approx.)
Certifications
200 g
EN 300 330
FCC Part 15
UL/CSA
2 x 106
1.81 MHz
Applicable for MDS 401/402
Table 5-7
Field data of SLG 40-S
Operating distance (Sa)
2 to 6 mm
Limit distance (Sg)
Diameter of transmission window (Ld)
Median deviation
Minimum distance from SLG to SLG (D)
8 mm
9 mm
 4.5 mm from middle
Da 50 mm
Db
FCC information
80 mm
Made in Germany
SIEMENS MOBY I SLG 40S
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Note
The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment:
Such modifications could void the user’s authority to operate the equipment.
5-8
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
Read/Write Devices
Transmission
window
Ld
Ld
sg
Field at Sa = 2 mm
sa
Field at Sa = 8 mm
View of top
View of side
Figure 5-8
View of the antenna
Transmission window:
To ensure reliable data communication, the antenna of the MDS must be
positioned within this field.
Metal-free space
a = 10 mm
b = 10 mm
MOBY I
SLG 40-S
Metal-free space with flush
installation
Note:
The limit and operating distances
are reduced when the metal-free
space is not adhered to.
Figure 5-9
Metal-free space for SLG 40-S
Definition of
distance D
Da
Db
Da
Db
50 mm
80 mm
The SLG electronics can be mounted directly
next to each other.
Figure 5-10
Distance D for SLG 40-S
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618
5-9
Read/Write Devices
Dimensions
(in mm)
Anti-kink cable protector, flexible in all directions
50
Minimum bending
radius: 20 mm
Cable length 0.5 m
Antenna head
75
65
Screw nuts
30
25
M18
Fine threading
Pitch 1.0
18
5.5
75
Antenna side
MOBY I
SLG 40-S
24
Top view of antenna head
Figure 5-11
5-10
Dimensional diagram of SLG 40-S
MOBY I Configuration, Installation and Service Manual
(4) J31069-D0033-U001-A8-7618

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Producer                        : AFPL Ghostscript 8.0
Create Date                     : 2003:12:15 10:28:59
Modify Date                     : 2003:12:16 14:55:42+01:00
Title                           : MOBY_I_e.pdf
Creator                         : PScript5.dll Version 5.2
Author                          : SB2851
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NXWMOBYI-SLG40SN

Navigation menu