Siemens MOBYU-SLGU92-0 Write-Read-Station for identification system User Manual data sheet

Siemens AG Write-Read-Station for identification system data sheet

data sheet

Download: Siemens MOBYU-SLGU92-0 Write-Read-Station for identification system User Manual data sheet
Mirror Download [FCC.gov]Siemens MOBYU-SLGU92-0 Write-Read-Station for identification system User Manual data sheet
Document ID222603
Application IDtskTgrw3nkvi9TlQwlgCtg==
Document Descriptiondata sheet
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize4.74kB (59214 bits)
Date Submitted2002-01-25 00:00:00
Date Available2002-01-25 00:00:00
Creation Date2001-04-10 09:03:52
Producing SoftwareAcrobat Distiller 4.05 for Macintosh
Document Lastmod2001-04-10 18:03:35
Document Titledata sheet

Datenblatt Produkt-Service engl 10.04.2001 09:01 Uhr Seite 1
CM
MY
CY CMY
MOBY U identification system with
a read/write range of up to 3 m
Latest Information on MOBY
Greater and greater demands are
being placed on identification
systems in the most varied of applications for the automotive industry,
logistics and distribution. Large
read/write distances, multi-tag capability or rapid and reliable data transfer under difficult conditions are
being demanded. Other requirements
are that out-of-range distances and
reflections do not influence the
results of identification, that other
2.4 GHz systems are not subjected
to interference and that little effort
is needed for installation. Maintenance-free operation and simple
system integration are also expected
by users as a matter of course.
In short, a whole series of requirements for which there are only a few
solutions.
MOBY U Identification System.
And there are many reasons in its
favour.
By using proven highly-innovative
UMTS/GSM technology from the telecommunications sector, it became possible to develop a fast and efficient
solution to the known problems encountered with conventional 2.4 GHz
systems. MOBY U thus features the
performance capability of innovative HT
technologies and also ensures continuity thanks to its compatibility with the
MOBY I identification system which is
already in use all over the world.
Main uses in logistics and industrial
production
• Main assembly lines in the automotive
industry (bodyshell construction,
paintshop, assembly)
• Vehicle identification/road access
monitoring for haulage companies,
depots etc.
• Containers/pallets/load-carrier
identification in transport logistics and
distribution
• Traffic control systems
• Assembly lines.
World-wide certification
MOBY U has been designed and
certified for heavy industrial use all round
the world. It uses the globally certified
ISM frequency band at 2.4 GHz and its
emission level of < 10 mW is far below
international limits, thus excluding the
possibility of any damage to health.
SOLUTIONS
Probedruck
Simple start-up and years of maintenance-free operation
The use of proven and innovative
UMTS/GSM technologies were the preconditions which enabled the following:
• A homogeneous transmission field
with circular polarization makes antenna
tuning unnecessary.
• Reflections, interference and overreach
are actively excluded.
• Automatic selection of free channels
• Automatic mutual synchronization of
up to 3 write/read units
• Can be directly mounted on metal
• Service functions for rapid fault
analysis
Datenblatt Produkt-Service engl 10.04.2001 09:01 Uhr Seite 2
CM
MY
CY CMY
The main characteristics
at a glance –
Innovative technologies simplify
configuration, start-up
and maintenance
• It uses the globally certified ISM
frequency band at 2.4 GHz
• Transmission ranges up to 3 m can be
limited in steps by software programming
• Read/write with a high level of net data
transmission speeds of up to
16 Kbyte/s
• Innovative GMS and UMTS functions
feature:
• a high level of data integrity
• suppression of overreach/reflections
and interference
• simple start-up, i.e. no interferencesource measurement and antenna
alignment
• no effect on other users in the frequency band thanks to automatic selection of free channels without interference (frequency hopping) and very
low emission values < 10 mW, EIRP
• Wide selection of robust data memories with a RAM of up to 32 Kbytes
(prepared for up to 256 Kbytes) and up
to +85 °C or +220 °C cyclically
• Multi-tag capability (up to 12 MDS)
• File handling with data access via logical
addresses (similar to DOS)
Siemens AG
Automation & Drives
Systems Engineering
P.O. Box 23 55
D-90713 Fürth, Germany
Siemens Aktiengesellschaft
Probedruck
• Call-compatible with MOBY I
• Mobile hand terminal (available soon)
• Designed and certified for heavy industrial use all round the world: CE, BAPT,
FCC, UL and CSA
• Ability to cope with future developments thanks to standardization acc.
to ISO 18000-4
• World-wide support and service
Mobile data memories MDS U 313,
MDS U 524 and MDS U 589
• 2 or 32 Kbyte RAM
• 32-bit serial number incl. 16 byte
uniquely recordable fixed code memory
• High degree of protection up to IP 68
• Operating temperature: -25 °C to +85 °C
• Special heat-resistant data memory up
to +220 °C for e.g. paintshop incl. KTL
• Robust long-life housing with the dimensions (mm): 111 x 67 x 23.5 or
ø 114 x 83 (MDS U 589).
SLG U 92 read/write unit
• Max. read/write distance: 3 m, can be
limited in steps by means of software
• Integrated antenna: with circular
polarization
Subject to change without prior notice
Order No. E80001-A78-P330-X-7600
Printed in Germany
21C6968.MK.SE.MB.MOBY.52.1.06 WS 04012.0
SEK. 30472 Dispostelle 06350
• RS422 or RS232 interface for link-up
to any systems
• RS232 service interface
• Degree of protection IP 65
• Operating temperature:
-25 °C to +70 °C
• Dimensions (mm): 290 x 135 x 42
(without connector)
MOBY U with tailor-made system integration for simple incorporation in
the respective application
• System integration by means of interface module (ASM 452, ASM 473, ASM
475), including FC for
PROFIBUS-DP-V1 and SIMATIC S7
• Windows 98/NT C library for direct
integration in the PC/SICOMP
• Can be integrated in any system via
RS232/RS422
More Information? Gladly!
Siemens AG – A&D SE MI 1
Automation & Drives
P.O. Box 23 55
D-90713 Fürth, Germany
Tel.: +49 (0) 911-750 27 66
Fax: +49 (0) 911-750 48 88
e-mail: moby@fthw.siemens.de
Web: www.siemens.de/moby
Excellence in
Automation & Drives:
Siemens

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2001:04:10 09:03:52
Producer                        : Acrobat Distiller 4.05 for Macintosh
Modify Date                     : 2001:04:10 18:03:35+02:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NXWMOBYU-SLGU92-0

Navigation menu