Siemens RF210R RFID Reader User Manual Technical Data RF210R Short Form
Siemens AG RFID Reader Technical Data RF210R Short Form
Siemens >
Contents
- 1. user manual I
- 2. user manual II
- 3. user manual
user manual I
Technical Data RF210R – Short Form Remarks: The RF210R manual does not yet exist, even not in German language. The RF210R manual, once completed, will contain detailed information about field-data, range for certain tags and information about how to implement the RF210R in a production site with communication modules. This detailed information may not be much relevant for RF210R FCC approval. Below given are short system overview and technical data which are required in order to run the RF210R for testing and to check the reader’s function. RF200 System overview SIMATIC RF200 is an inductive identification system, based on the standard ISO 15693, which was specially designed for industrial production for controlling and optimization material flow. Contrary to SIMATIC RF300, SIMATIC RF200 is designed for RFID applications for lower demands on performance (data volume, data transfer speed, diagnostics). SIMATIC RF200 is a low-price RFID system. Explanation of Technical terms Component Description Communications Modules Integration of an RFID Identification system is achieved by a communications module. Reader The reader achieves the communication with the tag and provides the tag with energy by the reader’s magnetic field. The reader also interfaces to various modules (i.e. SIMATIC S7 via ASM 475). Tag The RFID-tag stores all data relevant for production and is used as a substitute for optical barcode-tags. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. L'utilisation de ce dispositif est autorisée seulement aux deux conditions suivantes : (1) il ne doit pas produire de brouillage, et (2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. Overview of System Components compatible with RF210R System components Communications modules • • • • • • ASM 456 ASM 475 (S7 300/ ET 200M) RF160C RF170C RF180C RF182C Tags • • • • • • • • MDS D124 MDS D160 MDS D324 MDS D421 MDS D422 MDS D424 MDS D428 MDS D460 Technical Data RF210R (short form) Inductive interface (magnetic field) to transponder (tag). Carrier frequency for energy / data 13,56 MHz Antenna Integrated loop RF output power (RF power into antenna) 180mW (22.8dBm) into 50Ω Interface to communications module RS422 Baud rate 19200, 57600, 115200 Baud Functions Initialize tag, read tag, write on tag, get status data, antenna on/off, read tag serial number DC-Voltage (nominal) 24 V DC Display elements One pair of 2-color-LEDs (operating voltage, presence, error) Connector M12 (8-pin.) ROHS conformity ROHS according to EU 2002/95/EG Housing • Dimensions • Color • Material • Coating Metal Sleeve • Length: 83mm (3.3in); Diameter: 18mm (0.71in) • silver • CuZn40 Pb2 F43 • Ni4p**SN15 305 Fixing 2 Hex nuts, 18mm Degree of protection to EN 60529 IP67 Temperature Range (operating) -25°C … +70°C Weight without hex nuts / with hex nuts 50g (0.11 lbs) / 65g (0.14 lbs) Current consumption 40mA DC Power consumption 1.0 Watts Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Pin assignment RF210R (RS422 interface) M12 connector (male) Pin No. M12 plug Pin +24V -TX 0V (GND) +TX +RX -RX Not used (free) PE / shield LED indicator (display elements) RF210R LED colour Green Meaning Flashing Operating voltage available, reader NOT initialized Permanently on Operating voltage available. Reader initialized. Yellow Tag in field (tag presence) Red (flashing) Error according to error code table. Red (permanently on) Fatal error RF210R housing and dimensions RF210R total length: 83mm (3.27in); sleeve diameter: 18mm (0.71in).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Clemens Bopp (bc2899) Comments : Short Form Tech Data Company : Siemens AG Create Date : 2010:12:07 10:37:46+01:00 Keywords : Technical, Data, Overview Modify Date : 2011:02:16 11:29:07+01:00 Source Modified : D:20101207093731 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : Acrobat PDFMaker 8.1 für Word Metadata Date : 2011:02:16 11:29:07+01:00 Producer : Acrobat Distiller 8.2.2 (Windows) Format : application/pdf Creator : Clemens Bopp (bc2899) Title : Technical Data RF210R – Short Form Document ID : uuid:9ddf8934-61a5-457e-8488-8490c64e0ad9 Instance ID : uuid:2dd97e5a-fcc6-4693-8b32-3bff98903daf Page Layout : OneColumn Page Count : 3EXIF Metadata provided by EXIF.tools