Siemens RF210R RFID Reader User Manual Technical Data RF210R Short Form

Siemens AG RFID Reader Technical Data RF210R Short Form

Contents

user manual I

Technical Data RF210R – Short Form
Remarks: The RF210R manual does not yet exist, even not in German language. The
RF210R manual, once completed, will contain detailed information about field-data,
range for certain tags and information about how to implement the RF210R in a
production site with communication modules. This detailed information may not be much
relevant for RF210R FCC approval.
Below given are short system overview and technical data which are required in order to
run the RF210R for testing and to check the reader’s function.
RF200 System overview
SIMATIC RF200 is an inductive identification system, based on the standard ISO 15693,
which was specially designed for industrial production for controlling and optimization
material flow.
Contrary to SIMATIC RF300, SIMATIC RF200 is designed for RFID applications for
lower demands on performance (data volume, data transfer speed, diagnostics).
SIMATIC RF200 is a low-price RFID system.
Explanation of Technical terms
Component Description
Communications Modules Integration of an RFID Identification system is achieved by a
communications module.
Reader The reader achieves the communication with the tag and provides
the tag with energy by the reader’s magnetic field. The reader also
interfaces to various modules (i.e. SIMATIC S7 via ASM 475).
Tag The RFID-tag stores all data relevant for production and is used as a
substitute for optical barcode-tags.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. L'utilisation de ce dispositif est autorisée
seulement aux deux conditions suivantes :
(1) il ne doit pas produire de brouillage, et
(2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage
radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
Overview of System Components compatible with RF210R
System components
Communications modules ASM 456
ASM 475 (S7 300/ ET 200M)
RF160C
RF170C
RF180C
RF182C
Tags MDS D124
MDS D160
MDS D324
MDS D421
MDS D422
MDS D424
MDS D428
MDS D460
Technical Data RF210R (short form)
Inductive interface (magnetic field) to transponder
(tag). Carrier frequency for energy / data
13,56 MHz
Antenna Integrated loop
RF output power (RF power into antenna) 180mW (22.8dBm) into 50
Interface to communications module RS422
Baud rate 19200, 57600, 115200 Baud
Functions Initialize tag, read tag, write on tag, get status data,
antenna on/off, read tag serial number
DC-Voltage (nominal) 24 V DC
Display elements One pair of 2-color-LEDs
(operating voltage, presence, error)
Connector M12 (8-pin.)
ROHS conformity ROHS according to EU 2002/95/EG
Housing
Dimensions
Color
Material
Coating
Metal Sleeve
Length: 83mm (3.3in); Diameter: 18mm (0.71in)
silver
CuZn40 Pb2 F43
Ni4p**SN15 305
Fixing 2 Hex nuts, 18mm
Degree of protection to EN 60529 IP67
Temperature Range (operating) -25°C … +70°C
Weight without hex nuts / with hex nuts 50g (0.11 lbs) / 65g (0.14 lbs)
Current consumption 40mA
DC Power consumption 1.0 Watts
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Pin assignment RF210R (RS422 interface)
M12 connector (male) Pin No.
M12 plug
Pin
1 +24V
2 -TX
3 0V (GND)
4 +TX
5 +RX
6 -RX
7 Not used (free)
8 PE / shield
LED indicator (display elements) RF210R
LED colour Meaning
Flashing Operating voltage available, reader NOT initialized Green
Permanently on Operating voltage available. Reader initialized.
Yellow Tag in field (tag presence)
Red (flashing) Error according to error code table.
Red (permanently on) Fatal error
RF210R housing and dimensions
RF210R total length: 83mm (3.27in); sleeve diameter: 18mm (0.71in).

Navigation menu