Siemens RF280R RFID Reader 13.56 MHz User Manual SIMATIC RF200

Siemens AG RFID Reader 13.56 MHz SIMATIC RF200

Contents

SYH_RF200_76_Part 2

Download: Siemens RF280R RFID Reader 13.56 MHz User Manual SIMATIC RF200
Mirror Download [FCC.gov]Siemens RF280R RFID Reader 13.56 MHz User Manual SIMATIC RF200
Document ID3592553
Application ID6Hu7KqYaGNK5GN/wujCPKQ==
Document DescriptionSYH_RF200_76_Part 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize354.15kB (4426876 bits)
Date Submitted2017-10-04 00:00:00
Date Available2017-10-07 00:00:00
Creation Date2017-07-05 15:24:11
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-08-17 16:15:58
Document TitleSIMATIC RF200
Document CreatorAcrobat PDFMaker 17 für Word
Document Author: Siemens AG

Antennas
6.3 ANT 8
6.3.3
Transmission window
Ld
Length of the transmission window (= 3 mm)
Sa
Operating distance between antenna and transponder
Sg
Limit distance (maximum clear distance between upper surface of the reader and the antenna,
at which the transmission can still function under normal conditions)
Figure 6-10
6.3.4
Transmission window ANT 8
Flush-mounted in metal
Figure 6-11
ANT 8 flush-mounted in metal
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
173
Antennas
6.3 ANT 8
6.3.5
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 11
Minimum distances transponder edge to transponder edge
RF250R with ANT 8
MDS D117 / MDS D127
MDS D421 / MDS D521
≥ 20 mm
≥ 30 mm
Definition of distance D
≥ 50 mm
Figure 6-12
Minimum distance for ANT 8
SIMATIC RF200
174
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.3 ANT 8
≥ 50 mm
Figure 6-13
6.3.6
Face-to-face distance between two ANT 8s
Technical data
6GT2398-1CF10
6GT2398-1CF00
Product type designation
ANT 8
Electrical data
Maximum write/read distance ANT ↔ transponder 4 mm
(Sg)
Interfaces
Plug connection
4-pin (pin on antenna side)
Mechanical specifications
Housing
•
Material
•
Stainless steel
•
Color
•
silver
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
175
Antennas
6.3 ANT 8
6GT2398-1CF10
6GT2398-1CF00
Permitted ambient conditions
Ambient temperature
•
During operation
•
-25 ℃ ... +70 ℃
•
During transportation and storage
•
-40 °C ... +85 °C
Degree of protection to EN 60529
IP67
Shock according to EN 60721-3-7 Class 7 M31)
Vibration according to EN 60721-3-7 Class 7
M31)
500 m/s2
200 m/s2
Design, dimensions and weight
Dimensions (∅ x thread x L)
M8 x 1 x 38 mm
Weight
10 g without cable
140 g with cable
Type of mounting
2x stainless steel nuts M8 x 1
Cable length
3m
1)
6.3.7
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Dimension drawing
Figure 6-14
Dimension drawing ANT 8 (all values in mm)
SIMATIC RF200
176
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.4 ANT 12
6.4
ANT 12
6.4.1
Features
ANT 12
6.4.2
Characteristics
Area of application
Tool identification
Writing/reading distance
up to 16 mm (depending on the transponder)
Connecting cable
3 m or 0.6 m
Connectable readers
RF250R
Degree of protection
IP67 (front)
Ordering data
Table 6- 12
Ordering data ANT 12
Antenna
Article number
ANT 12
(including one plug-in antenna cable 3 m)
6GT2398-1CC00
Table 6- 13
Ordering data ANT 12 accessories
Accessories
Article number
Antenna cable, 3 m
6GT2398-0AH30
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
177
Antennas
6.4 ANT 12
6.4.3
Transmission window
Ld
Length of the transmission window (= 20 mm)
Sa
Operating distance between antenna and transponder
Sg
Limit distance (maximum clear distance between upper surface of the reader and the antenna,
at which the transmission can still function under normal conditions)
Figure 6-15
6.4.4
Transmission window ANT 12
Flush-mounted in metal
Figure 6-16
ANT 12 flush-mounted in metal
SIMATIC RF200
178
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.4 ANT 12
6.4.5
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 14
Minimum distances transponder edge to transponder edge
RF250R with ANT 12
MDS D117 / MDS D127
MDS D421 / MDS D422 / MDS D428 / MDS
D460 / MDS D522 / MDS D528
≥ 60 mm
≥ 80 mm
Definition of distance D
≥ 70 mm
Figure 6-17
Minimum distance for ANT 12
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
179
Antennas
6.4 ANT 12
≥ 100 mm
Figure 6-18
6.4.6
Face-to-face distance between two ANT 12s
Technical data
6GT2398-1CC00
6GT2398-1CC10
Product type designation
ANT 12
Electrical data
Maximum write/read distance ANT ↔ transponder 16 mm
(Sg)
Interfaces
Plug connection
4-pin (pin on antenna side)
Mechanical specifications
Housing
•
Material
•
Plastic Crastin
•
Color
•
Pale turquoise
•
-20 °C ... +70 °C
Permitted ambient conditions
Ambient temperature
•
During operation
SIMATIC RF200
180
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.4 ANT 12
6GT2398-1CC00
6GT2398-1CC10
•
During transportation and storage
•
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7
-40 °C ... +85 °C
IP67 (front)
M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2
Design, dimensions and weight
Dimensions (∅ x thread x L)
M12 x 1 x 40 mm
Weight
145 g
Type of mounting
2x plastic nuts M12 x 1
Cable length
3 m or 0.6 m
1)
6.4.7
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Dimension drawing
Figure 6-19
Dimension drawing ANT 12 (all values in mm)
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
181
Antennas
6.5 ANT 18
6.5
ANT 18
6.5.1
Features
ANT 18
6.5.2
Characteristics
Area of application
Small assembly lines
Writing/reading distance
up to 35 mm (depending on the transponder)
Connecting cable
3 m or 0.6 m
Connectable readers
RF250R
Degree of protection
IP67 (front)
Ordering data
Table 6- 15
Ordering data ANT 18
Antenna
Article number
ANT 18
(including one plug-in antenna cable 3 m)
6GT2398-1CA00
Table 6- 16
Ordering data ANT 18 accessories
Accessories
Article number
Antenna cable, 3 m
6GT2398-0AH30
SIMATIC RF200
182
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.5 ANT 18
6.5.3
Transmission window
Ld
Length of the transmission window (= 30 mm)
Sa
Operating distance between antenna and transponder
Sg
Limit distance (maximum clear distance between upper surface of the reader and the antenna,
at which the transmission can still function under normal conditions)
Figure 6-20
6.5.4
Transmission window ANT 18
Flush-mounted in metal
= 10 mm
= 10 mm
Figure 6-21
ANT 18 flush-mounted in metal
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
183
Antennas
6.5 ANT 18
6.5.5
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 17
Minimum distances transponder edge to transponder edge
RF250R with ANT 18
MDS D124 / MDS D160 / MDS D324
MDS D421 / MDS D422 / MDS D423 /
MDS D424 / MDS D425 / MDS D428 /
MDS D460 / MDS D522 / MDS D524 /
MDS D528
≥ 80 mm
≥ 100 mm
Definition of distance D
≥ 100 mm
Figure 6-22
Minimum distance for ANT 18
SIMATIC RF200
184
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.5 ANT 18
≥ 100 mm
Figure 6-23
6.5.6
Face-to-face distance between two ANT 18s
Technical data
6GT2398-1CA00
6GT2398-1CA10
Product type designation
ANT 18
Electrical data
Maximum write/read distance ANT ↔ transponder 35 mm
(Sg)
Interfaces
Plug connection
4-pin (pin on antenna side)
Mechanical specifications
Housing
•
Material
•
Plastic Crastin
•
Color
•
Pale turquoise
•
-20 °C ... +70 °C
Permitted ambient conditions
Ambient temperature
•
During operation
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
185
Antennas
6.5 ANT 18
6GT2398-1CA00
6GT2398-1CA10
•
During transportation and storage
•
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7
-40 °C ... +85 °C
IP67 (front)
M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2
Design, dimensions and weight
Dimensions (∅ x thread x L)
M18 x 1 x 55 mm
Weight
130 g
Type of mounting
2x plastic nuts M18 x 1
Cable length
3 m or 0.6 m
1)
6.5.7
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Dimension drawing
Figure 6-24
Dimension drawing ANT 18 (all values in mm)
SIMATIC RF200
186
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.6 ANT 30
6.6
ANT 30
6.6.1
Features
ANT 18
6.6.2
Characteristics
Area of application
Small assembly lines
Writing/reading distance
up to 55 mm (depending on the transponder)
Connecting cable
3m
Connectable readers
RF250R
Degree of protection
IP67 (front)
Ordering data
Table 6- 18
Ordering data ANT 30
Antenna
Article number
ANT 30
(including one plug-in antenna cable 3 m)
6GT2398-1CD00
Table 6- 19
Ordering data ANT 30 accessories
Accessories
Article number
Antenna cable, 3 m
6GT2398-0AH30
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
187
Antennas
6.6 ANT 30
6.6.3
Transmission window
Ld
Length of the transmission window (= 60 mm)
Sa
Operating distance between antenna and transponder
Sg
Limit distance (maximum clear distance between upper surface of the reader and the antenna,
at which the transmission can still function under normal conditions)
Figure 6-25
Transmission window ANT 30
SIMATIC RF200
188
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.6 ANT 30
6.6.4
Flush-mounted in metal
= 20 mm
= 20 mm
Figure 6-26
6.6.5
ANT 30 flush-mounted in metal
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 20
Minimum distances transponder edge to transponder edge
RF250R with ANT 30
MDS D124 / MDS D160 /
MDS D324 / MDS D423 /
MDS D424 / MDS D460 /
MDS D524
MDS D422 / MDS D425 /
MDS D428 / MDS D522 /
MDS D528
MDS D126 / MDS D426 /
MDS D526
≥ 100 mm
≥ 80 mm
≥ 150 mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
189
Antennas
6.6 ANT 30
Definition of distance D
≥ 100 mm
Figure 6-27
≥ 200 mm
Figure 6-28
6.6.6
Minimum distance for ANT 30
Face-to-face distance between two ANT 30s
Technical data
6GT2398-1CD00
Product type designation
ANT 30
Electrical data
Maximum write/read distance ANT ↔ transponder 60 mm
(Sg)
SIMATIC RF200
190
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.6 ANT 30
6GT2398-1CD00
Interfaces
Plug connection
4-pin (pin on antenna side)
Mechanical specifications
Housing
•
Material
•
Plastic Crastin
•
Color
•
Pale turquoise
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 °C ... +70 °C
•
During transportation and storage
•
-40 °C ... +85 °C
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7
IP67 (front)
M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2
Design, dimensions and weight
Dimensions (∅ x thread x L)
M30 x 1.5 x 61 mm
Weight
180 g
Type of mounting
2x plastic nuts M30 x 1.5
Cable length
3m
1)
6.6.7
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Dimension drawing
Figure 6-29
Dimension drawing ANT 30 (all values in mm)
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
191
Antennas
6.7 ANT D5
6.7
ANT D5
6.7.1
Features
ANT D5
6.7.2
Characteristics
Area of application
Storage, logistics and distribution
Writing/reading distance
up to 500 mm (depending on the transponder)
Connecting cable
3.3 m
Readers that can be connected
RF290R
Degree of protection
IP65
Ordering data
Table 6- 21
Ordering data of ANT D5
Antenna
Article number
ANT D5
(incl. one antenna connecting cable 3.3 m)
6GT2698-5AA10
Table 6- 22
Ordering data of ANT D5 accessories
Accessories
Article number
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
6GT2690-0AC00
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
6GT2894-0EA00
Antenna cable
Antenna extension cable, length 7.2 m
Length 3.3 m
6GT2691-0CH33
Length 10.5 m
6GT2691-0CN10
6GT2691-0DH72
SIMATIC RF200
192
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.7 ANT D5
6.7.3
Transmission window
Ld
Length of the transmission window (= 300 mm)
Sa
Operating distance between antenna and transponder
Sg
Limit distance (maximum clear distance between upper surface of the reader and the antenna,
at which the transmission can still function under normal conditions)
Figure 6-30
Transmission window for ANT D5
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
193
Antennas
6.7 ANT D5
6.7.4
Flush-mounted in metal
= 150 mm
Figure 6-31
6.7.5
Metal-free area for ANT D5
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
RF290R
MDS D100 / MDS D126 / MDS D139 /
MDS D165 / MDS D200 / MDS D261 /
MDS D339 / MDS D400 / MDS D426 /
MDS D526
MDS D124 / MDS D160 / MDS D324 /
MDS D424 / MDS D428 / MDS D460 /
MDS D524 / MDS D528 / MDS D560
≥1m
≥ 0.8 m
SIMATIC RF200
194
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.7 ANT D5
Minimum distances from antenna to antenna
RF290R with ANT D5
RF290R with ANT D6
RF290R with ANT D10
RF290R with ANT D5
≥2m
≥2m
≥2m
RF290R with ANT D6
≥2m
≥2m
≥2m
RF290R with ANT D10
≥2m
≥2m
≥2m
Definition of distance D
Figure 6-32
6.7.6
Distance D: ANT D5
Technical data
6GT2698-5AA10
Product type designation
ANT D5
Electrical data
Maximum write/read distance ANT ↔ transponder 500 mm
(Sg)
Interfaces
Plug connection
1-pin TNC plug
Mechanical specifications
Housing
•
Material
•
Aluminum/plastic
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
195
Antennas
6.7 ANT D5
6GT2698-5AA10
•
Color
•
gray/black
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 °C ... +55 °C
•
During transportation and storage
•
-25 ℃ ... +70 ℃
Degree of protection to EN 60529
IP65 (UL: for indoor use only)
Shock according to EN 60721-3-7 Class 7 M31)
Vibration according to EN 60721-3-7 Class 7
M31)
300 m/s2
•
10 m/s2 (9 ... 200 Hz)
•
15 m/s2 (200 ... 500 Hz)
Design, dimensions and weight
Dimensions (L x W x H)
380 x 380 x 110 mm
Weight
1.2 kg
Type of mounting
4x M6 or alternatively M8 screws
Cable length
3.3 m
1)
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
196
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.7 ANT D5
6.7.7
Dimension drawing
Figure 6-33
Dimension drawing for ANT D5
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
197
Antennas
6.8 ANT D6
6.8
ANT D6
6.8.1
Features
ANT D6
Characteristics
Area of application
6.8.2
•
Storage, logistics and distribution
•
Suitable for high-speed applications
with large writing/reading distance
Writing/reading distance
up to 650 mm (depending on the transponder)
Connecting cable
3.3 m; included in scope of supply
Cover
Available as accessory
Readers that can be connected
RF290R
Degree of protection
IP65 (also without cover)
Ordering data
Table 6- 23
ANT D6 ordering data
Antenna
Article number
ANT D6
(without cover, incl. one antenna connecting cable 3.3 m)
6GT2698-5AB00
Table 6- 24
Ordering data for ANT D6 accessories
Accessories
Article number
Covering hood for ANT D6
6GT2690-0AD00
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
6GT2690-0AC00
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
6GT2894-0EA00
Antenna cable
Antenna extension cable, length 7.2 m
Length 3.3 m
6GT2691-0CH33
Length 10.5 m
6GT2691-0CN10
6GT2691-0DH72
SIMATIC RF200
198
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.8 ANT D6
6.8.3
Transmission window
Lx
= 520 mm
Ly
= 420 mm
Figure 6-34
Transmission window for ANT D6
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
199
Antennas
6.8 ANT D6
6.8.4
Metal-free area
Flush-mounted in metal
Figure 6-35
6.8.5
Metal-free area for ANT D6
Minimum spacing
Definition of distance D
Figure 6-36
Distance D: ANT D6
SIMATIC RF200
200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.8 ANT D6
6.8.6
Technical data
6GT2698-5AB00
Product type designation
ANT D6
Electrical data
Maximum write/read distance ANT ↔ transponder 650 mm
(Sg)
Interfaces
Plug connection
1-pin TNC plug
Mechanical specifications
Housing
•
Material
•
Aluminum/plastic
•
Color
•
gray/black
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 °C ... +55 °C
•
During transportation and storage
•
-25 ℃ ... +70 ℃
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7
IP65 (UL: for indoor use only)
M31)
300 m/s2
Vibration according to EN 60721-3-7 Class 7 M31) •
•
10 m/s2 (9 ... 200 Hz)
15 m/s2 (200 ... 500 Hz)
Design, dimensions and weight
Dimensions (L x W x H)
580 x 480 x 110 mm
Weight
3.3 kg
(without cover)
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
201
Antennas
6.8 ANT D6
6GT2698-5AB00
Type of mounting
4 x M6 screws
Cable length
3.3 m
1)
6.8.7
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
Dimensional diagram
Figure 6-37
Dimension drawing for ANT D6
SIMATIC RF200
202
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.9 ANT D10
6.9
ANT D10
6.9.1
Features
ANT D10
Characteristics
Area of application
6.9.2
•
Storage, logistics and distribution, e.g. clothing industry,
laundries
•
Particularly when small MDS are used (e.g. MDS D124,
MDS D160) and when there is a long transmission field
Writing/reading distance
up to 480 mm (depending on the transponder)
Connecting cable
3.3 m; included in scope of supply
Cover
Included in scope of supply
Readers that can be connected
RF290R
Ordering data
Table 6- 25
Ordering data of ANT D10
Antenna
Article number
ANT D10
(incl. cover and one antenna connecting cable 3.3 m)
6GT2698-5AF00
Table 6- 26
Ordering data of ANT D10 accessories
Accessories
Article number
Antenna splitter
(incl. one antenna connecting cable 3.3 m)
6GT2690-0AC00
Antenna multiplexer
(incl. one antenna connecting cable 0.4 m)
6GT2894-0EA00
Antenna cable
Antenna extension cable, length 7.2 m
Length 3.3 m
6GT2691-0CH33
Length 10.5 m
6GT2691-0CN10
6GT2691-0DH72
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
203
Antennas
6.9 ANT D10
6.9.3
Transmission window
Lx
1050 mm
Ly
350 mm
Figure 6-38
Transmission window for ANT D10
SIMATIC RF200
204
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.9 ANT D10
6.9.4
Metal-free area
Flush-mounted in metal
Figure 6-39
Metal-free area for ANT D10
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
205
Antennas
6.9 ANT D10
6.9.5
Minimum spacing
Definition of distance D
Figure 6-40
6.9.6
Distance D: ANT D10
Technical data
6GT2698-5AF00
Product type designation
ANT D10
Electrical data
Maximum write/read distance ANT ↔ transponder 480 mm
(Sg)
Interfaces
Plug connection
1-pin TNC plug
Mechanical specifications
Housing
•
Material
•
Aluminum/plastic
•
Color
•
gray/black
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 °C ... +55 °C
•
During transportation and storage
•
-25 ℃ ... +70 ℃
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7
IP65 (UL: for indoor use only)
M31)
300 m/s2
SIMATIC RF200
206
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Antennas
6.9 ANT D10
6GT2698-5AF00
Vibration according to EN 60721-3-7 Class 7 M31) •
•
10
m/s2
(9 ... 200 Hz)
15 m/s2 (200 ... 500 Hz)
Design, dimensions and weight
Dimensions (L x W x H)
1150 x 365 x 115 mm
(with cover)
Weight
10 kg
Type of mounting
4 x M6 screws
Cable length
3.3 m
1)
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
207
Antennas
6.9 ANT D10
6.9.7
Dimensional diagram
Figure 6-41
Dimension drawing for ANT D10
SIMATIC RF200
208
System Manual, 07/2017, J31069-D0227-U001-A9-7619
7
Transponder
7.1
Memory configuration of ISO the transponders
Figure 7-1
Memory configuration of ISO the transponders
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
209
Transponder
7.2 MDS D100
Memory areas
Depending on the manufacturer of the transponder chip, the memory configuration of an ISO
transponder consists of varying sizes of user memory.
The typical sizes are 112 bytes, 256 bytes, 992 bytes EEPROM or 2000 bytes, 8192 bytes
FRAM. Each ISO transponder chip has an 8-byte long unique serial number (UID, read
only). This UID is transferred as an 8 byte value through a read command to address FFF0
with a length of 8.
Note
OPT memory
The transponders have an OTP memory. This was previously only supported by the RF300
readers.
7.2
MDS D100
7.2.1
Characteristics
MDS D100
7.2.2
Characteristics
Area of application
From simple identification such as electronic
barcode replacement/supplementation, through
warehouse and distribution logistics, right up to
product identification.
Memory size
112 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68
Ordering data
Table 7- 1
Ordering data for MDS D100
Article number
MDS D100
6GT2600-0AD10
SIMATIC RF200
210
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.2 MDS D100
Table 7- 2
Ordering data for MDS D100 accessory
Article number
7.2.3
Spacer
(in conjunction with fixing pocket 6GT2190-0AB00)
6GT2190-0AA00
Fixing pocket
(in conjunction with spacer 6GT2190-0AA00)
6GT2190-0AB00
Fixing pocket
(not suitable for fixing directly onto metal)
6GT2390-0AA00
Metal-free area
Direct mounting of the MDS D100 on metal is not allowed. A distance of ≥ 20 mm is
recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with
the fixing pocket 6GT2190-0AB00.
Mounting on metal
①
②
③
≥ 20 mm
Transponder
Metal
Non-metal
Figure 7-2
Mounting of the MDS D100 on metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
211
Transponder
7.2 MDS D100
Flush-mounting
≥ 20 mm
≥ 20 mm
①
②
③
Transponder
Metal
Non-metal
Figure 7-3
Flush-mounting of MDS D100 in metal with spacer
Note
If the minimum guide values (h or a) are not observed, a reduction of the field data results.
7.2.4
Technical data
Table 7- 3
Technical specifications for MDS D100
6GT2600-0AD10
Product type designation
SIMATIC MDS D100
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
SIMATIC RF200
212
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.2 MDS D100
6GT2600-0AD10
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PET
•
Color
•
White/black
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +80 ℃
•
outside the read/write field
•
-25 to +80 ℃
•
during storage
•
-25 to +80 ℃
Degree of protection to EN 60529
IP68
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810 1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810 1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85.6 x 54 x 0.9 mm
Weight
5g
Type of mounting
•
Fixing pocket
•
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
213
Transponder
7.2 MDS D100
7.2.5
Dimension drawing
Dimensions in mm
1)
Dimensions for mounting holes
Figure 7-4
MDS D100 dimension drawing
SIMATIC RF200
214
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.3 MDS D117
7.3
MDS D117
7.3.1
Features
MDS D117
7.3.2
Characteristics
Area of application
Very compact data carrier that can be cemented into
objects where precise positioning is necessary;
e.g. tool identification, workpiece holders etc..
Memory size
112 bytes of EEPROM user memory
Write/read range
See section "Field data (Page 39)."
Mounting in metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 4
Ordering data for MDS D117
Article number
MDS D117
6GT2600-0AG00
Pack of 10
7.3.3
Mounting in metal
Flush-mounted in metal
① Transponder
② Metal
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
215
Transponder
7.3 MDS D117
7.3.4
Technical specifications
Table 7- 5
Technical specifications for MDS D117
6GT2600-0AG00
Product type designation
SIMATIC MDS D117
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PPS
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +125 ℃
•
during storage
•
-40 to +125 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
Torsion and bending load
7M31)
1000 m/s2
200 m/s2
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
4 x 5.2 mm
SIMATIC RF200
216
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.4 MDS D124
6GT2600-0AG00
7.3.5
Weight
1g
Type of mounting
•
Fixing pocket
•
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Figure 7-5
Dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
217
Transponder
7.4 MDS D124
7.4
MDS D124
7.4.1
Characteristics
MDS D124
7.4.2
Characteristics
Area of application
Application areas in production automation (e.g. small
paintshops up to +180 °C)
Memory size
112 bytes of EEPROM user memory
Write/read range
See section "Field data (Page 39)".
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 6
Ordering data for MDS D124
Article number
MDS D124
Table 7- 7
6GT2600-0AC10
Ordering data for MDS D124 accessories
Article number
Spacer
6GT2690-0AK00
SIMATIC RF200
218
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.4 MDS D124
7.4.3
Mounting on metal
Mounting on metal
≥ 15 mm
Figure 7-6
Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer
Flush-mounting
≥ 15 mm
≥ 25 mm
Figure 7-7
Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with
spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
219
Transponder
7.4 MDS D124
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
7.4.4
Technical specifications
Table 7- 8
Technical specifications for MDS D124
6GT2600-0AC10
Product type designation
SIMATIC MDS D124
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PPS
•
Color
•
Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
•
during write/read access
outside the read/write field
•
-25 … +140 °C
•
from +125 ℃: 20% reduction in the limit distance
•
-40 to +180 ℃
SIMATIC RF200
220
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.4 MDS D124
6GT2600-0AC10
•
during storage
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
7M31)
Torsion and bending load
•
at +180 ℃: Tested up to 5000 hours or
3000 cycles
•
-40 to +125 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
1000 m/s2
200 m/s2
Not permitted
Design, dimensions and weight
7.4.5
Dimensions (Ø x H)
4 x 5.2 mm
Weight
5g
Type of mounting
•
1 x M3 screw 2)
≤ 1 Nm
•
Glued 3)
•
With spacer
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
3)
The processing instructions of the adhesive manufacturer must be observed.
Use of the MDS D124 in hazardous area
The mobile data memory MDS D124, device group II, category 1G or 1D may be installed
and operated in zones 0, 1 and 2 or in the zones 20, 21 and 22.
The following requirements of the 94/9/EC directive are met:
● EN 60079-0:2009
● EN 60079-11:2007
● EN 61241-11:2006
● EN 60079-26:2007
When used in hazardous areas, the MDS D124 must not be operated with field strengths > 5
A / m to avoid impermissible heating. This is not the case with readers from the SIMATIC RF
range (MOBY D, RF200 and RF300).
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
221
Transponder
7.4 MDS D124
Identification
II 1 G Ex ia IIC T3 to T6 Ga
or
II 1 D Ex ia IIIC T80 °C to T180 °C Da
TÜV 12 ATEX 084413 X
The temperature class or the maximum surface temperature depends on the maximum
ambient temperature. The relationship between temperature class (gas) or maximum surface
temperature (dust) can be found in the following table.
Table 7- 9
Ambient temperature
Ambient temperature range
Temperature class
Max. surface temperature
-25 ... +150 ℃
T3
T180
-25 ... +100 ℃
T4
T130
-25 ... +65 ℃
T5
T95
-25 ... +50 ℃
T6
T80
Note
Safety markings for hazardous areas
Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a
label with the device.
This must be affixed immediately next to the MDS D124 so that the label clearly relates to
the device.
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
SIMATIC RF200
222
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.4 MDS D124
Note
Installation and operating conditions for hazardous areas:
• Use of the device in the vicinity of processes generating high charges is not allowed.
• The device must be installed so that it is mechanically protected.
• For applications requiring devices of category 1, the device must be mounted on a
grounded, conductive base.
• It must only be cleaned with a damp cloth.
• The device is suitable for use in atmospheres containing dust, however not for full
immersion in dust.
7.4.6
Dimension drawing
Figure 7-8
Dimension drawing of MDS D124
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
223
Transponder
7.5 MDS D126
7.5
MDS D126
7.5.1
Characteristics
MDS D126
7.5.2
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for identification of
transport units in production-related logistics; can also be deployed
in harsh conditions
Memory size
112 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39)
Mounting on metal
Yes, with spacer
ISO standard
ISO-15693
Degree of protection
IP68
Ordering data
Table 7- 10
Ordering data for MDS D126
Article number
MDS D126
Table 7- 11
6GT2600-0AE00
Ordering data for MDS D126 accessories
Article number
Spacer
6GT2690-0AL00
SIMATIC RF200
224
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.5 MDS D126
7.5.3
Mounting on metal
Mounting on metal
≥ 25 mm
Figure 7-9
Mounting the MDS D126 / D426 / D526 on metal with spacer
Flush-mounted in metal
≥ 25 mm
≥ 50 mm
Figure 7-10
Flush installation of the MDS D126 / D426 / D526 in metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
225
Transponder
7.5 MDS D126
7.5.4
Technical specifications
Table 7- 12
Technical specifications for the MDS D126
6GT2600-0AE00
Product type designation
SIMATIC MDS D126
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PA6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
Torsion and bending load
7M31)
500 m/s2
200 m/s2
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
50 x 3.6 mm
SIMATIC RF200
226
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.5 MDS D126
6GT2600-0AE00
7.5.5
Weight
13 g
Type of mounting
•
1 x M4 screw 2)
≤ 1 Nm
•
Glued 3)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
3)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Dimensions in mm
Figure 7-11
Dimension drawing of MDS D126
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
227
Transponder
7.6 MDS D127
7.6
MDS D127
7.6.1
Features
MDS D127
7.6.2
Characteristics
Area of application
Very compact data carrier that can be screwed into
areas where precise positioning is necessary;
e.g. tool identification, workpiece holders etc.
Memory size
112 bytes of EEPROM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 13
Ordering data for MDS D127
Article number
MDS D127
6GT2600-0AF00
Pack of 10
(A screw-in aid is supplied with each pack)
SIMATIC RF200
228
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.6 MDS D127
7.6.3
Mounting in metal
Flush-mounted in metal
① Metal
② Transponders
Note
Damage to the transponder due to improper mounting
To screw the MDS D127 into a suitable thread, use the supplied screw-in tool. This avoids
damage to the MDS D127.
Figure 7-12
Screw-in aid for mounting the MDS D127
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
229
Transponder
7.6 MDS D127
7.6.4
Technical specifications
Table 7- 14
Technical specifications for MDS D127
6GT2600-0AF00
Product type designation
SIMATIC MDS D127
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PA6
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +100 ℃
•
outside the read/write field
•
-40 to +125 ℃
•
during storage
•
-40 to +125 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
Torsion and bending load
7M31)
1000 m/s2
200 m/s2
Not permitted
SIMATIC RF200
230
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.6 MDS D127
6GT2600-0AF00
Design, dimensions and weight
Dimensions (Ø x H)
M6 x 5.8 mm
Weight
1g
Type of mounting
•
Glued 2)
•
1 x M3 screw
1)
2)
7.6.5
The values for shock and vibration are maximum values and must not be applied continuously.
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Figure 7-13
Dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
231
Transponder
7.7 MDS D139
7.7
MDS D139
7.7.1
Characteristics
MDS D139
Characteristics
Area of application
Applications in production logistics and in assembly
lines subject to high temperatures (up to +220 °C)
Typical application areas:
7.7.2
•
Paintshops and their preparatory treatments)
•
Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
•
Top coat area with drying furnaces
•
Washing areas at temperatures > 85 °C
•
Other applications with higher temperatures
Memory size
112 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 15
Ordering data for MDS D139
Article number
MDS D139
Table 7- 16
6GT2600-0AA10
Ordering data for MDS D139 accessory
Article number
Spacer
6GT2690-0AA00
Quick change holder
(Ø x H): 22 x 60 mm
6GT2690-0AH00
Quick change holder
(Ø x H): 22 x 47 mm
6GT2690-0AH10
SIMATIC RF200
232
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.7 MDS D139
7.7.3
Metal-free area
Direct mounting of the MDS D139 on metal is not allowed. A distance of ≥ 30 mm is
recommended. This can be achieved using spacers (see "Transponder holders
(Page 355)").
Mounting on metal
≥ 30 mm
Figure 7-14
Mounting the MDS D139 on metal with spacer
Flush-mounting
It is possible to mount the MDS D139 in metal. With large antennas, for example ANT D5,
this leads to a reduction of ranges.
≥ 30 mm
≥ 100 mm
Figure 7-15
Flush-mounting of the MDS D139 in metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
233
Transponder
7.7 MDS D139
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is
recommended that a test is performed in critical applications.
7.7.4
Mounting in metal
It is possible to mount the MDS D139 in metal. With large antennas, for example ANT D5,
this leads to a reduction of ranges.
= 100 mm
= 30 mm
Figure 7-16
7.7.5
MDS D139: Mounting in metal
Cleaning the transponder
NOTICE
Cleaning the transponder
Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These
cleaning methods result in damage to the transponder.
Clean the transponder only with the chemical cleansing agents listed in the section
Chemical resistance of the reader and transponders (Page 89).
SIMATIC RF200
234
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.7 MDS D139
7.7.6
Technical specifications
Table 7- 17
Technical specifications for MDS D139
6GT2600-0AA10
Product type designation
SIMATIC MDS D139
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PPS
•
Color
•
Black
Recommended distance to metal
≥ 30 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
•
•
during write/read access
outside the read/write field
during storage
•
-25 … +140 °C
•
from +125 ℃: 20% reduction in the limit distance
•
-40 to +220 ℃
•
at +200 ℃: Tested up to 5000 hours or
6000 cycles
•
at +220 ℃: Tested up to 2000 hours or
2000 cycles
•
-40 to +100 ℃
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
235
Transponder
7.7 MDS D139
6GT2600-0AA10
Degree of protection to EN 60529
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.7.7
Dimensions (Ø x H)
85 x 15 mm
Weight
50 g
Type of mounting
1 x M5 screw 2)
1.5 Nm
The values for shock and vibration are maximum values and must not be applied continuously.
2)
For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient).
Use of the MDS D139 in hazardous areas
The MDS D139 mobile data memory is classed as a piece of simple, electrical equipment
and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the 94/9/EC directive are met:
● EN 60079-0:2006
● EN 60079-15:2005
● EN 61241-0:2006
● EN 61241-1:2004
SIMATIC RF200
236
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.7 MDS D139
Identification
II 3 G Ex nA II T2
II 3 D Ex tD A22 IP68 T 220°C
KEMA 09 ATEX 0133 X
Ta: -25 ... +220°C
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
Note
Installations- und Betriebsbedingungen für den Ex-Schutzbereich:
a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist
untersagt.
b) Das Gerät ist mechanisch geschützt zu montieren.
c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen.
d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas:
a) Use of the equipment in the vicinity of processes generating high charges is not allowed.
b) The equipment must be mechanically protected when installed.
c) Installation must be performed on a grounded and conductive mounting surface.
d) Cleaning only with a wet cloth
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex :
a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite.
b) L'appareil doit être monté de manière à être protégé mécaniquement.
c) Le montage doit être effectué sur un socle conducteur mis à la terre.
d) Nettoyage uniquement avec un chiffon humide
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
237
Transponder
7.7 MDS D139
7.7.8
Dimension drawings
Dimensional drawing of MDS D139
Figure 7-17
Dimensional drawing of MDS D139
Dimensions in mm
SIMATIC RF200
238
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.8 MDS D160
7.8
MDS D160
7.8.1
Characteristics
MDS D160
Characteristics
Area of application
Thanks to its rugged packaging, the MDS D160 is a transponder that
can be used under extreme environmental conditions. It is washable,
heat-resistant and resistant to all chemicals generally used in the
laundry process.
Typical applications are, for example:
7.8.2
•
Rented work clothing
•
Hotel laundry
•
Surgical textiles
•
Hospital clothing
•
Dirt collection mats
•
Clothing for nursing homes/hostels
Memory size
112 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 18
Ordering data for MDS D160
Article number
MDS D160
Table 7- 19
6GT2600-0AB10
Ordering data for MDS D160 accessories
Article number
Spacer
6GT2690-0AG00
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
239
Transponder
7.8 MDS D160
7.8.3
Mounting on metal
Mounting on metal
①
②
③
Transponder
≥ 10 mm
Metal carrier
Spacer
Figure 7-18
Mounting the MDS D160 on metal with spacer
Note
Going below the minimum distance (h)
If the minimum distance (h) is not observed, a reduction of the field data results.
In critical applications, it is recommended that a test is performed.
Flush-mounting
Flush-mounting of the MDS D160 in metal is not permitted!
7.8.4
Technical specifications
Table 7- 20
Technical specifications for the MDS D160
6GT2600-0AB10
Product type designation
SIMATIC MDS D160
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
SIMATIC RF200
240
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.8 MDS D160
6GT2600-0AB10
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PPS
•
Color
•
beige
Recommended distance to metal
≥ 10 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 … +85 °C
•
outside the read/write field
•
-40 … +175 °C
•
from +125 ℃: for 1000 hours, 20% reduction
of the limit distance
•
at +175 ℃: 100 washing cycles tested
•
at +220 ℃: Tested once for up to 30 seconds
•
-25 to +100 ℃
•
during storage
Mechanical strength
•
Isostatic pressure
•
300 bar for 5 min
•
Axial pressure
•
1000 N for 10 s
•
Radial pressure
•
1000 N for 10 s
Resistance to chemicals
All chemicals normally used in the washing process
MDS lifespan
At least 100 wash cycles
Degree of protection
•
IP68
24 hours, 2 bar, +20 °C
•
IPx9K
Shock according to IEC 68-2-271)
400 m/s2
18 ms; 6 axes; 2000 repetitions/h
Vibration according to IEC 68-2-61)
100 m/s2
10 ... 2000 Hz; 3 axes; 2.5 h
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
241
Transponder
7.8 MDS D160
6GT2600-0AB10
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
16 x 3 mm
Weight
1.2 g
Type of mounting
•
Patched
•
Sewn in
•
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Note
Regeneration time between washing cycles
The regeneration time for the MDS D160 between washing cycles must be at least 24 hours.
7.8.5
Dimension drawings
Dimensional drawing of MDS D160
Dimensions in mm
Figure 7-19
Dimensional drawing of MDS D160
SIMATIC RF200
242
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.9 MDS D165
Dimensional drawing of spacer
Dimensions in mm
Figure 7-20
7.9
MDS D165
7.9.1
Features
Dimensional drawing of spacer
MDS D165 (special version)
Characteristics
Area of application
The design of the transponder (self-adhesive label)
permits a variety of designs, guaranteeing optimum
dimensioning for the widest variety of applications.
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identification.
7.9.2
Memory size
112 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP65
Ordering data
Table 7- 21
Ordering data for MDS D165
Article number
MDS D165 (special version ISO-CARD)
6GT2600-1AB00-0AX0
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
243
Transponder
7.9 MDS D165
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
7.9.3
Technical data
Table 7- 22
Technical specifications for MDS D165
6GT2600-1AB00-0AX0
Product type designation
SIMATIC MDS D165
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
112 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
•
Material
Color
•
Top
•
PET plastic (label
material)
•
Inlay
•
PET plastic (carrier
material)
•
Antenna
•
Aluminum
•
Bottom
•
Double-sided transfer adhesive on silicon paper
•
White
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 ... +80 °C
SIMATIC RF200
244
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.9 MDS D165
6GT2600-1AB00-0AX0
•
outside the read/write field
•
•
during storage
• +20 to +30 ℃
Can be stored for 2 years, determined by the
durability of the adhesive.
Degree of protection
-25 to +80 ℃
IP65
Design, dimensions and weight
Dimensions (L x W x H)
86 x 54 x 0.3 mm
Weight
1g
Type of mounting
Glued with self-adhesive label 1)
1)
7.9.4
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Dimensions in mm
Figure 7-21
Dimension drawing of MDS D165
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
245
Transponder
7.10 MDS D200
7.10
MDS D200
7.10.1
Features
MDS D200
7.10.2
Characteristics
Area of application
From simple identification such as electronic barcode replacement/supplementation, through
warehouse and distribution logistics, right
up to product identification.
Memory size
256 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
15693 with Tag-it HFI technology
Degree of protection
IP67
Ordering data
Table 7- 23
Ordering data for MDS D200
Article number
MDS D200 (special version ISO-CARD)
Table 7- 24
6GT2600-1AD00-0AX0
Ordering data for MDS D200 accessories
Article number
Spacer
(in conjunction with fixing pocket 6GT2190-0AB00)
6GT2190-0AA00
Fixing pocket
(in conjunction with spacer 6GT2190-0AA00)
6GT2190-0AB00
Fixing pocket
(not suitable for fixing directly onto metal)
6GT2390-0AA00
SIMATIC RF200
246
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.10 MDS D200
7.10.3
Mounting on metal
Mounting on metal
①
②
③
≥ 20 mm
Transponder
Metal
Non-metal
Figure 7-22
Mounting of the MDS D200 on metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
247
Transponder
7.10 MDS D200
Flush-mounting
≥ 20 mm
≥ 20 mm
①
②
③
Transponder
Metal
Non-metal
Figure 7-23
Flush-mounting of MDS D200 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
7.10.4
Technical data
Table 7- 25
Technical specifications for MDS D200
6GT2600-1AD00-0AX0
Product type designation
SIMATIC MDS D200
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
256 bytes EEPROM
SIMATIC RF200
248
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.10 MDS D200
6GT2600-1AD00-0AX0
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 25 ℃)
> 1014
Write cycles (at < 25 ℃)
> 106
Data retention time (at < 25 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PET
•
Color
•
White
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-20 to +60 ℃
•
outside the read/write field
•
-20 to +60 ℃
•
during storage
•
-20 to +60 ℃
Degree of protection to EN 60529
IP67
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810 1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810 1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85 x 54 x 0.8 mm
Weight
5g
Type of mounting
•
Fixing pocket
•
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
249
Transponder
7.11 MDS D261
7.10.5
Dimension drawing
Dimensions in mm
Figure 7-24
7.11
MDS D261
7.11.1
Features
Dimension drawing of MDS D200
MDS D261
Characteristics
Area of application
The design of the transponder (self-adhesive label)
permits a variety of designs, guaranteeing optimum
dimensioning for the widest variety of applications.
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identification.
7.11.2
Memory size
256 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP65
Ordering data
Table 7- 26
Ordering data for MDS D261
Article number
MDS D261
6GT2600-1AA00-0AX0
SIMATIC RF200
250
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.11 MDS D261
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
7.11.3
Technical data
Table 7- 27
Technical specifications of MDS D261
6GT2600-1AA01-0AX0
Product type designation
SIMATIC MDS D261
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
256 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
•
Material
Color
•
Top
•
PET plastic (label
material)
•
Inlay
•
PET plastic (carrier
material)
•
Antenna
•
Aluminum
•
Bottom
•
Double-sided transfer adhesive on silicon paper
•
White
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-20 ... +60 °C
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
251
Transponder
7.11 MDS D261
6GT2600-1AA01-0AX0
•
outside the read/write field
•
•
During transportation and storage
• +20 to +30 ℃
Can be stored for 2 years, determined by the
durability of the adhesive
Degree of protection
-20 … +85 °C
IP65
Design, dimensions and weight
Dimensions (L x W x H)
55 x 55 x 0.3 mm
Weight
1g
Type of mounting
Glued with self-adhesive label 1)
1)
7.11.4
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Dimensions in mm
Figure 7-25
Dimension drawing of MDS D261
SIMATIC RF200
252
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.12 MDS D324
7.12
MDS D324
7.12.1
Characteristics
MDS D324
Characteristics
Area of application
Production and distribution logistics
and product identification
Can also be used in harsh environments under extreme environmental
conditions (e.g. with higher temperature
load).
7.12.2
Memory size
992 bytes of EEPROM user memory
Write/read range
See section "Field data (Page 39)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67; IPx9K
Ordering data
Table 7- 28
Ordering data MDS D324
Article number
MDS D324
Table 7- 29
6GT2600-3AC00
Ordering data MDS D324 accessories
Article number
Spacer
6GT2690-0AK00
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
253
Transponder
7.12 MDS D324
7.12.3
Mounting on metal
Mounting on metal
≥ 15 mm
Figure 7-26
Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer
Flush-mounting
≥ 15 mm
≥ 25 mm
Figure 7-27
Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with
spacer
SIMATIC RF200
254
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.12 MDS D324
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
7.12.4
Technical specifications
Table 7- 30
Technical specifications of MDS D324
6GT2600-3AC00
Product type designation
SIMATIC MDS D324
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
992 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +125 ℃
•
outside the read/write field
•
-40 to +140 ℃
•
during storage
•
-40 to +140 ℃
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
255
Transponder
7.12 MDS D324
6GT2600-3AC00
Degree of protection to EN 60529
•
IP67
•
IPx9K
Shock according to EN 60721-3-7 Class 7M31)
1000 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.12.5
Dimensions (Ø x H)
27 x 4 mm
Weight
5g
Type of mounting
•
1 x M3 screw 2)
≤ 1 Nm
•
Glued 3)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
3)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Figure 7-28
Dimension drawing of MDS D324
All dimensions in mm
SIMATIC RF200
256
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.13 MDS D339
7.13
MDS D339
7.13.1
Characteristics
MDS D339
Characteristics
Area of application
Applications in production automation with high
temperature demands (up to +220 °C)
Typical application areas:
7.13.2
•
Paintshops and their preparatory treatments
•
Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
•
Top coat area with drying furnaces
•
Washing areas at temperatures > 85 °C
•
Other applications with higher temperatures
Memory size
992 bytes of EEPROM user memory
Write/read range
See section Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 31
Ordering data for MDS D339
Article number
MDS D339
Table 7- 32
6GT2600-3AA10
Ordering data for MDS D339 accessories
Article number
Spacer
6GT2690-0AA00
Quick change holder
(Ø x H): 22 x 60 mm
6GT2690-0AH00
Quick change holder
(Ø x H): 22 x 47 mm
6GT2690-0AH10
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
257
Transponder
7.13 MDS D339
7.13.3
Mounting on metal
Direct mounting of the MDS D139/D339 on metal is not allowed. A distance of ≥ 30 mm is
recommended. This can be achieved using spacers (see "Transponder holders
(Page 355)").
Mounting on metal
≥ 30 mm
Figure 7-29
Mounting the MDS D139/D339 on metal with spacer
Flush-mounting
It is possible to mount the MDS D139/D339 in metal. With large antennas, for example ANT
D5, this leads to a reduction of ranges.
≥ 30 mm
≥ 100 mm
Figure 7-30
Flush-mounting of the MDS D139/D339 in metal with spacer
SIMATIC RF200
258
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.13 MDS D339
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is
recommended that a test is performed in critical applications.
7.13.4
Mounting in metal
It is possible to mount the MDS D339 in metal. With large antennas, for example ANT D5,
this leads to a reduction of ranges.
= 100 mm
= 30 mm
Figure 7-31
7.13.5
MDS D339: Mounting in metal
Cleaning the transponder
NOTICE
Cleaning the transponder
Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These
cleaning methods result in damage to the transponder.
Clean the transponder only with the chemical cleansing agents listed in the section
Chemical resistance of the reader and transponders (Page 89).
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
259
Transponder
7.13 MDS D339
7.13.6
Technical specifications
Table 7- 33
Technical specifications of MDS D339
6GT2600-3AA10
Product type designation
SIMATIC MDS D339
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
992 bytes EEPROM
•
OTP memory
•
16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PPS
•
Color
•
Black
Recommended distance to metal
≥ 30 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +100 ℃
•
outside the read/write field
•
-40 to +220 ℃
•
from +125 ℃: 20% reduction in the limit distance
•
at +200 ℃: Tested up to 5000 hours or
6000 cycles
•
at +220 ℃: Tested up to 2000 hours or
2000 cycles
•
-40 to +100 ℃
•
during storage
SIMATIC RF200
260
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.13 MDS D339
6GT2600-3AA10
Degree of protection to EN 60529
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.13.7
Dimensions (Ø x H)
85 x 15 mm
Weight
50 g
Type of mounting
1 x M5 screw 2)
1.5 Nm
The values for shock and vibration are maximum values and must not be applied continuously.
2)
For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient).
Use of the MDS D339 in hazardous areas
The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment
and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the 94/9/EC directive are met:
● EN 60079-0:2006
● EN 60079-15:2005
● EN 61241-0:2006
● EN 61241-1:2004
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
261
Transponder
7.13 MDS D339
Identification
II 3 G Ex nA II T6
Ii 3 D Ex tD A22 IP68 T 210°C
KEMA 09 ATEX 0133 X
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
Note
Installations- und Betriebsbedingungen für den Ex-Schutzbereich:
a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist
untersagt.
b) Das Gerät ist mechanisch geschützt zu montieren.
c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen.
d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas:
a) Use of the equipment in the vicinity of processes generating high charges is not allowed.
b) The equipment must be mechanically protected when installed.
c) Installation must be performed on a grounded and conductive mounting surface.
d) Cleaning only with a wet cloth
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex :
a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite.
b) L'appareil doit être monté de manière à être protégé mécaniquement.
c) Le montage doit être effectué sur un socle conducteur mis à la terre.
d) Nettoyage uniquement avec un chiffon humide
SIMATIC RF200
262
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.13 MDS D339
7.13.8
Dimensional drawing
MDS D339
Figure 7-32
Dimension drawing of the MDS D339
Dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
263
Transponder
7.14 MDS D400
7.14
MDS D400
7.14.1
Features
MDS D400
7.14.2
Characteristics
Area of application
Simple identification such as electronic barcode replacement/supplements, from warehouse and distribution logistics right through to product identification.
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67
Ordering data
Table 7- 34
Ordering data of MDS D400
Article number
MDS D400
Table 7- 35
6GT2600-4AD00
Ordering data of MDS D400 accessories
Article number
Spacer
(in conjunction with fixing pocket 6GT2190-0AB00)
6GT2190-0AA00
Fixing pocket
(in conjunction with spacer 6GT2190-0AA00)
6GT2190-0AB00
Fixing pocket
(not suitable for fixing directly onto metal)
6GT2390-0AA00
SIMATIC RF200
264
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.14 MDS D400
7.14.3
Mounting on metal
Mounting on metal
It is possible to mount the MDS D400 on metal.
①
②
③
≥ 20 mm
Transponder
Metal
Non-metal
Figure 7-33
Mounting of the MDS D400 on metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
265
Transponder
7.14 MDS D400
Flush-mounted in metal
≥ 20 mm
≥ 20 mm
①
②
③
Transponder
Metal
Non-metal
Figure 7-34
Flush-mounting of MDS D400 in metal with spacer
Note
If the minimum guide values (h) are not observed, this will result in a reduction of the field
data.
7.14.4
Technical specifications
Table 7- 36
Technical specifications for MDS D400
6GT2600-4AD00
Product type designation
SIMATIC MDS D400
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
SIMATIC RF200
266
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.14 MDS D400
6GT2600-4AD00
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 25 ℃)
> 1012
Write cycles (at < 25 ℃)
> 1012
Data retention time (at < 25 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
PVC
•
Color
•
White
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-20 to +60 ℃
•
outside the read/write field
•
-20 to +60 ℃
•
during storage
•
-20 to +60 ℃
Degree of protection to EN 60529
IP67
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810 1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85 x 54 x 0.8 mm
Weight
5g
Type of mounting
•
Fixing lug
•
Glued 2)
1)
The values for vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
267
Transponder
7.14 MDS D400
7.14.5
Dimension drawing
Figure 7-35
Dimensional drawing MDS D400 (dimensions in mm)
SIMATIC RF200
268
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.15 MDS D421
7.15
MDS D421
7.15.1
Characteristics
MDS D421
Characteristics
Area of application
The MDS D421 is designed for tool coding in accordance
with DIN 69873.
It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders.
The rugged housing of the MDS D421 means that it can
also be used in a harsh industrial environment without problems.
7.15.2
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
Ordering data
Table 7- 37
Ordering data of MDS D421
Article number
MDS D421
6GT2600-4AE00
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
269
Transponder
7.15 MDS D421
7.15.3
Mounting on metal
Mounting on metal
Figure 7-36
Mounting of MDS D421 on metal
Figure 7-37
Mounting of MDS D421 in metal
Flush-mounting
Flush-mounting of MDS D421 in metal with tools
Figure 7-38
Flush-mounting of MDS D421 in metal with tools
SIMATIC RF200
270
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.15 MDS D421
b1
0.5 x 45°
b2
0.3 x 45° or R 0.3
d1
10 (-0.04.. -0.13)
d2
10 (+0.09... 0)
t1
4.5 (-0... -0.1)
t2
4.6 (+0.2... 0)
All dimensions in mm
Note
Installation instruction
The MDS should not protrude out of the locating hole; it must be flush with the outside
contour.
The mounting instructions of the MDS and the conditions associated with the application
(e.g. peripheral speed, temperature, and use of coolant) must be observed during the
installation.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D421 using your finger; antenna side to the outside (see figure "Flushmounting of MDS D421 in metal with tools")
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D421 in metal with tools
Installation examples
Figure 7-39
Installation example of MDS D421 in a steep cone
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
271
Transponder
7.15 MDS D421
Figure 7-40
7.15.4
Installation example of MDS D421 in a stud bolt
Technical specifications
Table 7- 38
Technical specifications for the MDS D421
6GT2600-4AE00
Product type designation
SIMATIC MDS D421
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
SIMATIC RF200
272
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.15 MDS D421
6GT2600-4AE00
Degree of protection to EN 60529
•
IP67
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock according to EN 60721-3-7 Class 7M31)
1000 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.15.5
Dimensions (Ø x H)
10 x 4.5 mm
Weight
Approx. 1 g
Type of mounting
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Figure 7-41
Dimension drawing of MDS D421
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
273
Transponder
7.16 MDS D422
7.16
MDS D422
7.16.1
Characteristics
MDS D422
7.16.2
Characteristics
Area of application
Identification of metallic workpiece holders, workpieces or
containers
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39).
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68
Ordering data
Table 7- 39
Ordering data of MDS D422
Article number
MDS D422
6GT2600-4AF00
A screw-in aid is included in the scope of supply per packaging
unit
7.16.3
Mounting in metal
Flush-mounting
Figure 7-42
Mounting of MDS D422 in metal
SIMATIC RF200
274
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.16 MDS D422
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D422 using your fingers; with antenna to the outside
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D422 in metal with tools
7.16.4
Technical specifications
Table 7- 40
Technical specifications for the MDS D422
6GT2600-4AF00
Product type designation
SIMATIC MDS D422
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
285 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF; brass nickel plated
•
Color
•
Black/silver
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
275
Transponder
7.16 MDS D422
6GT2600-4AF00
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.16.5
Dimensions (Ø x H)
20 x 6 mm
Weight
13 g
Type of mounting
•
Glued 2)
•
1 x transponder thread M20
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Dimensions in mm
Figure 7-43
Dimensional drawing of MDS D422
SIMATIC RF200
276
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.17 MDS D423
7.17
MDS D423
7.17.1
Characteristics
MDS D423
7.17.2
Characteristics
Area of application
Identification of metallic workpiece holders, workpieces or containers, production automation
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 41
Ordering data of MDS D423
Article number
MDS D423
Table 7- 42
6GT2600-4AA00
Ordering data of MDS D423 accessories
Article number
Fixing hood RF330T / MDS D423
7.17.3
6GT2690-0AE00
Mounting on metal
Mounting on metal
Direct mounting of the MDS D423 on metal is possible.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
277
Transponder
7.17 MDS D423
Figure 7-44
Mounting the MDS D423 on metal
Flush-mounted in metal
It is possible to mount the MDS D423 in metal.
≥ 10 mm
Figure 7-45
Flush-mounting of the MDS D423 in metal with 10 mm clearance
SIMATIC RF200
278
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.17 MDS D423
Figure 7-46
Flush-mounting of the MDS D423 in metal without clearance
Note
Reduction of the write/read range
Note that when the device is flush-mounted in metal without a surrounding clearance ≥ 10
mm, the write/read range is significantly reduced.
7.17.4
Technical specifications
Table 7- 43
Technical specifications of MDS D423
6GT2600-4AA00
Product type designation
SIMATIC MDS D423
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Plastic PPS
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
279
Transponder
7.17 MDS D423
6GT2600-4AA00
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
Pressure resistance
Torsion and bending load
7M31)
500 m/s2
200 m/s2
•
Low pressure resistant
vacuum dryer: up to 20 mbar
•
High pressure resistant
(see degree of protection IPx9K)
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
30 x 8 mm
Weight
15 g
Type of mounting
1 x M4 screw 2)
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
SIMATIC RF200
280
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.18 MDS D424
7.17.5
Dimensional drawing
Dimensions in mm
Figure 7-47
Dimension drawing for MDS D423
7.18
MDS D424
7.18.1
Characteristics
MDS D424
Characteristics
Area of application
Production and distribution logistics as well as in
assembly and production lines,
can also be used in a harsh industrial environment
without problem
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67; IPx9K
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
281
Transponder
7.18 MDS D424
7.18.2
Ordering data
Table 7- 44
Ordering data of MDS D424
Article number
MDS D424
Table 7- 45
6GT2600-4AC00
Ordering data of MDS D424 accessories
Article number
Spacer
7.18.3
6GT2690-0AK00
Mounting on metal
Mounting on metal
≥ 15 mm
Figure 7-48
Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer
SIMATIC RF200
282
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.18 MDS D424
Flush-mounting
≥ 15 mm
≥ 25 mm
Figure 7-49
Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with
spacer
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
7.18.4
Technical specifications
Table 7- 46
Technical specifications for the MDS D424
6GT2600-4AC00
Product type designation
SIMATIC MDS D424
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
283
Transponder
7.18 MDS D424
6GT2600-4AC00
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
•
IP67
•
IPx9K
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7M31)
Vibration according to EN 60721-3-7 Class
Torsion and bending load
7M31)
1000 m/s2
200 m/s2
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
27 x 4 mm
Weight
5g
Type of mounting
•
Glued 2)
•
1x screw M3 3)
≤ 1 Nm
1)
2)
The values for shock and vibration are maximum values and must not be applied continuously.
The processing instructions of the adhesive manufacturer must be observed.
) To prevent it loosening during operation, secure the screw with screw-locking varnish.
SIMATIC RF200
284
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.19 MDS D425
7.18.5
Dimension drawing
Figure 7-50
Dimension drawing of MDS D424
All dimensions in mm
7.19
MDS D425
7.19.1
Characteristics
MDS D425
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for screw
mounting
Use in assembly and production lines in the powertrain
sector; ideal for mounting on motors, gearboxes, and workpiece holders
Rugged packaging of the MDS D425; can therefore also be
used under extreme environmental conditions without problem
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)".
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
285
Transponder
7.19 MDS D425
7.19.2
Ordering data
Table 7- 47
Ordering data of MDS D425
Article number
MDS D425
7.19.3
Application example
Figure 7-51
7.19.4
6GT2600-4AG00
Application example
Technical specifications
Table 7- 48
Technical specifications for the MDS D425
6GT2600-4AG00
Product type designation
SIMATIC MDS D425
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
SIMATIC RF200
286
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.19 MDS D425
6GT2600-4AG00
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +125 ℃
•
during storage
•
-40 to +125 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to IEC 68-2-271)
500 m/s2
Vibration according to IEC 68-2-61)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
24 x 10 mm (without set screw)
Weight
35 g
Type of mounting
1x transponder set screw M6
SW 22; ≤ 6 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
287
Transponder
7.20 MDS D426
7.19.5
Dimension drawing
Dimensions in mm
Figure 7-52
Dimension drawing of MDS D425
7.20
MDS D426
7.20.1
Characteristics
MDS D426
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for identification of
transport units in production-related logistics; can also be deployed in
harsh conditions
Memory size
2000 bytes of FRAM user memory
Write/read range
See section Field data (Page 39)
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68
SIMATIC RF200
288
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.20 MDS D426
7.20.2
Mounting on metal
Mounting on metal
≥ 25 mm
Figure 7-53
Mounting the MDS D126 / D426 / D526 on metal with spacer
Flush-mounted in metal
≥ 25 mm
≥ 50 mm
Figure 7-54
Flush installation of the MDS D126 / D426 / D526 in metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
289
Transponder
7.20 MDS D426
7.20.3
Ordering data
Table 7- 49
Ordering data of MDS D426
Article number
MDS D426
Table 7- 50
6GT2600-4AH00
Ordering data of MDS D426 accessories
Article number
Spacer
7.20.4
6GT2690-0AL00
Technical specifications
Table 7- 51
Technical specifications for the MDS D426
6GT2600-4AH00
Product type designation
SIMATIC MDS D426
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
SIMATIC RF200
290
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.20 MDS D426
6GT2600-4AH00
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to IEC 68-2-271)
50 m/s2
Vibration according to IEC 68-2-61)
20 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.20.5
Dimensions (Ø x H)
50 x 3.6 mm
Weight
13 g
Type of mounting
1 x M4 screw 2)
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
Dimension drawing
Dimensions in mm
Figure 7-55
Dimension drawing of MDS D426
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
291
Transponder
7.21 MDS D428
7.21
MDS D428
7.21.1
Characteristics
MDS D428
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for screw
mounting.
Use in assembly and production lines in the powertrain
sector.
The rugged housing of the MDS D428 means that it can
also be used in extreme environmental conditions without
problems.
7.21.2
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 52
Ordering data of MDS D428
Article number
MDS D428
6GT2600-4AK00-0AX0
SIMATIC RF200
292
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.21 MDS D428
7.21.3
Application example
Figure 7-56
7.21.4
Application example
Technical specifications
Table 7- 53
Technical specifications for the MDS D428
6GT2600-4AK00
Product type designation
SIMATIC MDS D428
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
293
Transponder
7.21 MDS D428
6GT2600-4AK00
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +125 ℃
•
during storage
•
-40 to +125 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to IEC 68-2-271)
500 m/s2
Vibration according to IEC 68-2-61)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
24 x 20 mm (without set screw)
Weight
35 g
Type of mounting
1x transponder set screw M8
SW 22; ≤ 8 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
294
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.22 MDS D460
7.21.5
Dimension drawing
Dimensions in mm
Figure 7-57
Dimension drawing of MDS D428
7.22
MDS D460
7.22.1
Characteristics
MDS D460
Characteristics
Area of application
Identification in small assembly lines; can also be used in a harsh industrial environment
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
295
Transponder
7.22 MDS D460
7.22.2
Ordering data
Table 7- 54
Ordering data of MDS D460
Article number
MDS D460
Table 7- 55
6GT2600-4AB00
Ordering data of MDS D460 accessories
Article number
Spacer
7.22.3
6GT2690-0AG00
Mounting on metal
Mounting option on metal with spacer
①
②
③
Transponder
≥ 10 mm
Metal
Spacer
Figure 7-58
Mounting the MDS D460 on metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
In critical applications, it is recommended that a test is performed.
Flush-mounting
Flush-mounting of the MDS D460 in metal is not permitted!
SIMATIC RF200
296
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.22 MDS D460
7.22.4
Technical specifications
Table 7- 56
Technical specifications for MDS D460
6GT2600-4AB00
Product type designation
SIMATIC MDS D460
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
2000 bytes FRAM
•
OTP memory
•
16 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 10 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
•
IP67
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to IEC 68-2-271)
Vibration according to IEC
68-2-61)
Torsion and bending load
500 m/s2
200 m/s2
Not permitted
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
297
Transponder
7.22 MDS D460
6GT2600-4AB00
Design, dimensions and weight
7.22.5
Dimensions (Ø x H)
16 x 3 mm
Weight
3g
Type of mounting
•
Glued 2)
•
With spacer
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawings
Dimensional drawing of MDS D460
Dimensions in mm
Figure 7-59
Dimensional drawing of MDS D460
Dimensional drawing of spacer
Dimensions in mm
Figure 7-60
Dimensional drawing of spacer
SIMATIC RF200
298
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.23 MDS D521
7.23
MDS D521
7.23.1
Characteristics
MDS D521
Characteristics
Area of application
The MDS D521 is designed for tool coding according to DIN
69873.
It can be used wherever small data carriers and exact positioning
are required, e.g. tool identification, workpiece holders.
The rugged housing of the MDS D521 means that it can also be
used in a harsh industrial environment without problems.
7.23.2
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
Ordering data
Table 7- 57
Ordering data for MDS D521
Article number
MDS D521
7.23.3
6GT2600-5AE00
Mounting on metal
Mounting on metal
Figure 7-61
Mounting of MDS D521 on metal
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
299
Transponder
7.23 MDS D521
Flush-mounting
Figure 7-62
Mounting of MDS D521 in metal
Flush-mounting of MDS D521 in metal with tools
Figure 7-63
Flush-mounting of MDS D521 in metal with tools
b1
0.5 x 45°
b2
0.3 x 45° or R 0.3
d1
10 (-0.04.. -0.13)
d2
10 (+0.09... 0)
t1
4.5 (-0... -0.1)
t2
4.6 (+0.2... 0)
All dimensions in mm
Note
Installation instruction
The MDS should not protrude out of the locating hole; it must be flush with the outside
contour.
The mounting instructions of the MDS and the conditions associated with the application
(e.g. peripheral speed, temperature, and use of coolant) must be observed during the
installation.
SIMATIC RF200
300
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.23 MDS D521
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D521 using your finger; antenna side to the outside (see figure "Flushmounting of MDS D521 in metal with tools")
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D521 in metal with tools
Installation examples
7.23.4
Figure 7-64
Installation example of MDS D521 in a steep cone
Figure 7-65
Installation example of MDS D521 in a stud bolt
Technical specifications
Table 7- 58
Technical specifications for MDS D521
6GT2600-5AE00
Product type designation
SIMATIC MDS D521
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
301
Transponder
7.23 MDS D521
6GT2600-5AE00
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
•
IP67
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to EN 60721-3-7 Class 7M31)
1000 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
10 x 4.5 mm
Weight
1g
Type of mounting
Glued 2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
SIMATIC RF200
302
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.24 MDS D522
7.23.5
Dimension drawing
Figure 7-66
Dimension drawing of MDS D521
All dimensions in mm
7.24
MDS D522
7.24.1
Characteristics
MDS D522
Characteristics
Area of application
Identification of metallic workpiece holders, workpieces or containers
Memory size
8192 bytes of FRAM user memory
Write/read range
See "Field data (Page 39)."
Mounting in metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
303
Transponder
7.24 MDS D522
7.24.2
Ordering data
Table 7- 59
Ordering data for MDS D522
Article number
MDS D522
6GT2600-5AF00
Units in a package: 10 units
A mounting aid is included in the scope of supply per packaging
unit.
7.24.3
Mounting in metal
Flush-mounting
Figure 7-67
Mounting of MDS D522 in metal
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D522 using your fingers; with antenna to the outside
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D522 in metal with tools
SIMATIC RF200
304
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.24 MDS D522
7.24.4
Technical specifications
Table 7- 60
Technical specifications for MDS D522
6GT2600-5AF00
Product type designation
SIMATIC MDS D522
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
285 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF; brass nickel plated
•
Color
•
Black/silver
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
20 x 6 mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
305
Transponder
7.24 MDS D522
6GT2600-5AF00
7.24.5
Weight
13 g
Type of mounting
•
Glued 2)
•
1 x transponder thread M20
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
Dimension drawing
Figure 7-68
Dimensional drawing of MDS D522
All dimensions in mm
SIMATIC RF200
306
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.25 MDS D522 special variant
7.25
MDS D522 special variant
7.25.1
Characteristics
MDS D522 special version
7.25.2
Characteristics
Area of application
Identification of metallic workpiece holders or workpieces
Memory size
8192 bytes of FRAM user memory
Write/read range
See "Field data (Page 39)."
Mounting in metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68
Ordering data
Table 7- 61
MDS D522 special version
Article number
MDS D522 special version
6GT2600-5AF00-0AX0
Units in a package: 10 units
A mounting aid is included in the scope of supply per packaging
unit.
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
307
Transponder
7.25 MDS D522 special variant
7.25.3
Mounting in metal
Flush-mounting
Figure 7-69
7.25.4
Flush installation of the MDS D522 special version in metal without clearance
Installation instructions
The transponder MDS D522 special version is designed to be mounted once.
Note the following instructions when mounting the MDS D522 in a workpiece to avoid
damaging the transponder:
● Prepare the workpiece according to the following drawing.
● Using the accompanying mounting aid, press the transponder with uniform and evenly
distributed pressure into the drilled hole until the transponder locks in place. Make sure
that the transponder does not become tilted.
SIMATIC RF200
308
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.25 MDS D522 special variant
Figure 7-70
Dimension drawing: Workpiece drill hole for mounting the MDS D522 special version
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
309
Transponder
7.25 MDS D522 special variant
7.25.5
Technical specifications
Table 7- 62
Technical data of MDS D522 special version
6GT2600-5AF00-0AX0
Product type designation
SIMATIC MDS D522 special version
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
18 (+0.1) × 5.2 mm
Weight
Approx. 1.2 g
Type of mounting
Clipping in once (with accompanying tool)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
310
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.25 MDS D522 special variant
7.25.6
Dimensional drawing
Figure 7-71
Dimension drawing MDS D522 special version
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
311
Transponder
7.26 MDS D524
7.26
MDS D524
7.26.1
Characteristics
MDS D524
Characteristics
Area of application
Production and distribution logistics as well as in assembly and production lines,
can also be used in a harsh industrial environment without
problem
7.26.2
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67; IPx9K
Ordering data
Table 7- 63
Ordering data for MDS D524
Article number
MDS D524
Table 7- 64
6GT2600-5AC00
Ordering data of MDS D524 accessories
Article number
Spacer
6GT2690-0AK00
SIMATIC RF200
312
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.26 MDS D524
7.26.3
Mounting on metal
Mounting on metal
≥ 15 mm
Figure 7-72
Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer
Flush-mounting
≥ 15 mm
≥ 25 mm
Figure 7-73
Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with
spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
313
Transponder
7.26 MDS D524
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
7.26.4
Technical specifications
Table 7- 65
Technical specifications for MDS D524
6GT2600-5AC00
Product type designation
SIMATIC MDS D524
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Epoxy resin
•
Color
•
Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
SIMATIC RF200
314
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.26 MDS D524
6GT2600-5AC00
Degree of protection to EN 60529
•
IP67
•
IPx9K
Shock according to EN 60721-3-7 Class 7M31)
1000 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
7.26.5
Dimensions (Ø x H)
27 x 4 mm
Weight
5g
Type of mounting
•
Glued 2)
•
1x screw M3 3)
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
) To prevent it loosening during operation, secure the screw with screw-locking varnish.
Dimension drawing
Figure 7-74
Dimensional drawing of MDS D524
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
315
Transponder
7.27 MDS D526
7.27
MDS D526
7.27.1
Characteristics
MDS D526
7.27.2
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for identification
of transport units in production-related logistics; can also be deployed in harsh conditions
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68
Ordering data
Table 7- 66
Ordering data for MDS D526
Article number
MDS D526
Table 7- 67
6GT2600-5AH00
Ordering data for MDS D526 accessories
Article number
Spacer
6GT2690-0AL00
SIMATIC RF200
316
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.27 MDS D526
7.27.3
Mounting on metal
Mounting on metal
≥ 25 mm
Figure 7-75
Mounting the MDS D126 / D426 / D526 on metal with spacer
Flush-mounted in metal
≥ 25 mm
≥ 50 mm
Figure 7-76
Flush installation of the MDS D126 / D426 / D526 in metal with spacer
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
317
Transponder
7.27 MDS D526
7.27.4
Technical specifications
Table 7- 68
Technical specifications for MDS D526
6GT2600-5AH00
Product type designation
SIMATIC MDS D526
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
•
OTP
•
32 bytes
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +100 ℃
•
during storage
•
-40 to +100 ℃
Degree of protection to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock according to IEC 68-2-271)
500 m/s2
Vibration according to IEC
68-2-61)
Torsion and bending load
200 m/s2
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
50 x 3.6 mm
SIMATIC RF200
318
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.27 MDS D526
6GT2600-5AH00
7.27.5
Weight
13 g
Type of mounting
1 x M4 screw 2)
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
Dimension drawing
Figure 7-77
Dimensional drawing of MDS D526
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
319
Transponder
7.28 MDS D528
7.28
MDS D528
7.28.1
Characteristics
MDS D528
Characteristics
Area of application
Compact and rugged ISO transponder; suitable for screw
mounting
Use in assembly and production lines in the powertrain
sector
The rugged housing of the MDS D528 means that it can
also be used in extreme environmental conditions without
problems.
7.28.2
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data (Page 39)"
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
Ordering data
Table 7- 69
Ordering data for MDS D528
Article number
MDS D528
6GT2600-5AK00
SIMATIC RF200
320
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.28 MDS D528
7.28.3
Application example
Figure 7-78
7.28.4
Application example
Technical specifications
Table 7- 70
Technical specifications for MDS D528
6GT2600-5AK00
Product type designation
SIMATIC MDS D528
Memory
Memory configuration
•
UID
•
8 bytes
•
User memory
•
8192 bytes FRAM
•
OTP
•
32 bytes
Read cycles (at < 40 ℃)
> 1012
Write cycles (at < 40 ℃)
> 1012
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (Sg)
Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
321
Transponder
7.28 MDS D528
6GT2600-5AK00
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6 GF
•
Color
•
Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
•
during write/read access
•
-25 to +85 ℃
•
outside the read/write field
•
-40 to +125 ℃
•
during storage
•
-40 to +125 ℃
•
IP68
2 hours, 2 bar, +20 °C
•
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Degree of protection to EN 60529
Shock according to IEC 68-2-271)
500 m/s2
Vibration according to IEC 68-2-61)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
24 x 20 mm (without set screw)
Weight
35 g
Type of mounting
1x transponder set screw M8
SW 22; ≤ 8 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF200
322
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Transponder
7.28 MDS D528
7.28.5
Dimension drawing
Figure 7-79
Dimensional drawing of MDS D528
All dimensions in mm
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
323

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Siemens AG
Create Date                     : 2017:07:05 15:24:11+02:00
Modify Date                     : 2017:08:17 16:15:58+02:00
Subject                         : SIMATIC Ident
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2017:08:17 16:15:58+02:00
Creator Tool                    : Acrobat PDFMaker 17 für Word
Document ID                     : uuid:bbce7b7a-f188-413e-baf5-913b15b647bb
Instance ID                     : uuid:43ff9585-ecf0-4b2e-97d4-8826cb4d5232
Format                          : application/pdf
Title                           : SIMATIC RF200
Description                     : SIMATIC Ident
Creator                         : Siemens AG
Producer                        : Adobe PDF Library 15.0
Source Modified                 : D:20170705132114
Company                         : Siemens AG
Comments                        : 
Edition                         : 0.00347050074367873
System                          : SIMATIC Ident
Print-year                      : 2010 - 2017
Document-class                  : System Manual
Document-class-mrl              : ​
Product-group                   : RFID systems
Order-nr                        : J31069-D0227-U001-A9-7619
Company-short                   : Siemens
Company-long                    : Siemens AG
Page Layout                     : OneColumn
Page Mode                       : UseOutlines
Page Count                      : 151
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NXW-RF280R

Navigation menu