Siemens RF280R RFID Reader 13.56 MHz User Manual SIMATIC RF200
Siemens AG RFID Reader 13.56 MHz SIMATIC RF200
Siemens >
Contents
- 1. SYH_RF200_76_Part 1
- 2. SYH_RF200_76_Part 2
- 3. SYH_RF200_76_Part 3
SYH_RF200_76_Part 2
Antennas 6.3 ANT 8 6.3.3 Transmission window Ld Length of the transmission window (= 3 mm) Sa Operating distance between antenna and transponder Sg Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-10 6.3.4 Transmission window ANT 8 Flush-mounted in metal Figure 6-11 ANT 8 flush-mounted in metal SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 173 Antennas 6.3 ANT 8 6.3.5 Minimum spacing Note Extension of the data transmission time if distance values are undershot If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from transponder to transponder (without multitag mode) Table 6- 11 Minimum distances transponder edge to transponder edge RF250R with ANT 8 MDS D117 / MDS D127 MDS D421 / MDS D521 ≥ 20 mm ≥ 30 mm Definition of distance D ≥ 50 mm Figure 6-12 Minimum distance for ANT 8 SIMATIC RF200 174 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.3 ANT 8 ≥ 50 mm Figure 6-13 6.3.6 Face-to-face distance between two ANT 8s Technical data 6GT2398-1CF10 6GT2398-1CF00 Product type designation ANT 8 Electrical data Maximum write/read distance ANT ↔ transponder 4 mm (Sg) Interfaces Plug connection 4-pin (pin on antenna side) Mechanical specifications Housing • Material • Stainless steel • Color • silver SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 175 Antennas 6.3 ANT 8 6GT2398-1CF10 6GT2398-1CF00 Permitted ambient conditions Ambient temperature • During operation • -25 ℃ ... +70 ℃ • During transportation and storage • -40 °C ... +85 °C Degree of protection to EN 60529 IP67 Shock according to EN 60721-3-7 Class 7 M31) Vibration according to EN 60721-3-7 Class 7 M31) 500 m/s2 200 m/s2 Design, dimensions and weight Dimensions (∅ x thread x L) M8 x 1 x 38 mm Weight 10 g without cable 140 g with cable Type of mounting 2x stainless steel nuts M8 x 1 Cable length 3m 1) 6.3.7 Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 6-14 Dimension drawing ANT 8 (all values in mm) SIMATIC RF200 176 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.4 ANT 12 6.4 ANT 12 6.4.1 Features ANT 12 6.4.2 Characteristics Area of application Tool identification Writing/reading distance up to 16 mm (depending on the transponder) Connecting cable 3 m or 0.6 m Connectable readers RF250R Degree of protection IP67 (front) Ordering data Table 6- 12 Ordering data ANT 12 Antenna Article number ANT 12 (including one plug-in antenna cable 3 m) 6GT2398-1CC00 Table 6- 13 Ordering data ANT 12 accessories Accessories Article number Antenna cable, 3 m 6GT2398-0AH30 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 177 Antennas 6.4 ANT 12 6.4.3 Transmission window Ld Length of the transmission window (= 20 mm) Sa Operating distance between antenna and transponder Sg Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-15 6.4.4 Transmission window ANT 12 Flush-mounted in metal Figure 6-16 ANT 12 flush-mounted in metal SIMATIC RF200 178 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.4 ANT 12 6.4.5 Minimum spacing Note Extension of the data transmission time if distance values are undershot If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from transponder to transponder (without multitag mode) Table 6- 14 Minimum distances transponder edge to transponder edge RF250R with ANT 12 MDS D117 / MDS D127 MDS D421 / MDS D422 / MDS D428 / MDS D460 / MDS D522 / MDS D528 ≥ 60 mm ≥ 80 mm Definition of distance D ≥ 70 mm Figure 6-17 Minimum distance for ANT 12 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 179 Antennas 6.4 ANT 12 ≥ 100 mm Figure 6-18 6.4.6 Face-to-face distance between two ANT 12s Technical data 6GT2398-1CC00 6GT2398-1CC10 Product type designation ANT 12 Electrical data Maximum write/read distance ANT ↔ transponder 16 mm (Sg) Interfaces Plug connection 4-pin (pin on antenna side) Mechanical specifications Housing • Material • Plastic Crastin • Color • Pale turquoise • -20 °C ... +70 °C Permitted ambient conditions Ambient temperature • During operation SIMATIC RF200 180 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.4 ANT 12 6GT2398-1CC00 6GT2398-1CC10 • During transportation and storage • Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7 -40 °C ... +85 °C IP67 (front) M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2 Design, dimensions and weight Dimensions (∅ x thread x L) M12 x 1 x 40 mm Weight 145 g Type of mounting 2x plastic nuts M12 x 1 Cable length 3 m or 0.6 m 1) 6.4.7 Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 6-19 Dimension drawing ANT 12 (all values in mm) SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 181 Antennas 6.5 ANT 18 6.5 ANT 18 6.5.1 Features ANT 18 6.5.2 Characteristics Area of application Small assembly lines Writing/reading distance up to 35 mm (depending on the transponder) Connecting cable 3 m or 0.6 m Connectable readers RF250R Degree of protection IP67 (front) Ordering data Table 6- 15 Ordering data ANT 18 Antenna Article number ANT 18 (including one plug-in antenna cable 3 m) 6GT2398-1CA00 Table 6- 16 Ordering data ANT 18 accessories Accessories Article number Antenna cable, 3 m 6GT2398-0AH30 SIMATIC RF200 182 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.5 ANT 18 6.5.3 Transmission window Ld Length of the transmission window (= 30 mm) Sa Operating distance between antenna and transponder Sg Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-20 6.5.4 Transmission window ANT 18 Flush-mounted in metal = 10 mm = 10 mm Figure 6-21 ANT 18 flush-mounted in metal SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 183 Antennas 6.5 ANT 18 6.5.5 Minimum spacing Note Extension of the data transmission time if distance values are undershot If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from transponder to transponder (without multitag mode) Table 6- 17 Minimum distances transponder edge to transponder edge RF250R with ANT 18 MDS D124 / MDS D160 / MDS D324 MDS D421 / MDS D422 / MDS D423 / MDS D424 / MDS D425 / MDS D428 / MDS D460 / MDS D522 / MDS D524 / MDS D528 ≥ 80 mm ≥ 100 mm Definition of distance D ≥ 100 mm Figure 6-22 Minimum distance for ANT 18 SIMATIC RF200 184 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.5 ANT 18 ≥ 100 mm Figure 6-23 6.5.6 Face-to-face distance between two ANT 18s Technical data 6GT2398-1CA00 6GT2398-1CA10 Product type designation ANT 18 Electrical data Maximum write/read distance ANT ↔ transponder 35 mm (Sg) Interfaces Plug connection 4-pin (pin on antenna side) Mechanical specifications Housing • Material • Plastic Crastin • Color • Pale turquoise • -20 °C ... +70 °C Permitted ambient conditions Ambient temperature • During operation SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 185 Antennas 6.5 ANT 18 6GT2398-1CA00 6GT2398-1CA10 • During transportation and storage • Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7 -40 °C ... +85 °C IP67 (front) M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2 Design, dimensions and weight Dimensions (∅ x thread x L) M18 x 1 x 55 mm Weight 130 g Type of mounting 2x plastic nuts M18 x 1 Cable length 3 m or 0.6 m 1) 6.5.7 Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 6-24 Dimension drawing ANT 18 (all values in mm) SIMATIC RF200 186 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.6 ANT 30 6.6 ANT 30 6.6.1 Features ANT 18 6.6.2 Characteristics Area of application Small assembly lines Writing/reading distance up to 55 mm (depending on the transponder) Connecting cable 3m Connectable readers RF250R Degree of protection IP67 (front) Ordering data Table 6- 18 Ordering data ANT 30 Antenna Article number ANT 30 (including one plug-in antenna cable 3 m) 6GT2398-1CD00 Table 6- 19 Ordering data ANT 30 accessories Accessories Article number Antenna cable, 3 m 6GT2398-0AH30 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 187 Antennas 6.6 ANT 30 6.6.3 Transmission window Ld Length of the transmission window (= 60 mm) Sa Operating distance between antenna and transponder Sg Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-25 Transmission window ANT 30 SIMATIC RF200 188 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.6 ANT 30 6.6.4 Flush-mounted in metal = 20 mm = 20 mm Figure 6-26 6.6.5 ANT 30 flush-mounted in metal Minimum spacing Note Extension of the data transmission time if distance values are undershot If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from transponder to transponder (without multitag mode) Table 6- 20 Minimum distances transponder edge to transponder edge RF250R with ANT 30 MDS D124 / MDS D160 / MDS D324 / MDS D423 / MDS D424 / MDS D460 / MDS D524 MDS D422 / MDS D425 / MDS D428 / MDS D522 / MDS D528 MDS D126 / MDS D426 / MDS D526 ≥ 100 mm ≥ 80 mm ≥ 150 mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 189 Antennas 6.6 ANT 30 Definition of distance D ≥ 100 mm Figure 6-27 ≥ 200 mm Figure 6-28 6.6.6 Minimum distance for ANT 30 Face-to-face distance between two ANT 30s Technical data 6GT2398-1CD00 Product type designation ANT 30 Electrical data Maximum write/read distance ANT ↔ transponder 60 mm (Sg) SIMATIC RF200 190 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.6 ANT 30 6GT2398-1CD00 Interfaces Plug connection 4-pin (pin on antenna side) Mechanical specifications Housing • Material • Plastic Crastin • Color • Pale turquoise Permitted ambient conditions Ambient temperature • During operation • -20 °C ... +70 °C • During transportation and storage • -40 °C ... +85 °C Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7 IP67 (front) M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7 M31) 200 m/s2 Design, dimensions and weight Dimensions (∅ x thread x L) M30 x 1.5 x 61 mm Weight 180 g Type of mounting 2x plastic nuts M30 x 1.5 Cable length 3m 1) 6.6.7 Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 6-29 Dimension drawing ANT 30 (all values in mm) SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 191 Antennas 6.7 ANT D5 6.7 ANT D5 6.7.1 Features ANT D5 6.7.2 Characteristics Area of application Storage, logistics and distribution Writing/reading distance up to 500 mm (depending on the transponder) Connecting cable 3.3 m Readers that can be connected RF290R Degree of protection IP65 Ordering data Table 6- 21 Ordering data of ANT D5 Antenna Article number ANT D5 (incl. one antenna connecting cable 3.3 m) 6GT2698-5AA10 Table 6- 22 Ordering data of ANT D5 accessories Accessories Article number Antenna splitter (incl. one antenna connecting cable 3.3 m) 6GT2690-0AC00 Antenna multiplexer (incl. one antenna connecting cable 0.4 m) 6GT2894-0EA00 Antenna cable Antenna extension cable, length 7.2 m Length 3.3 m 6GT2691-0CH33 Length 10.5 m 6GT2691-0CN10 6GT2691-0DH72 SIMATIC RF200 192 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.7 ANT D5 6.7.3 Transmission window Ld Length of the transmission window (= 300 mm) Sa Operating distance between antenna and transponder Sg Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-30 Transmission window for ANT D5 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 193 Antennas 6.7 ANT D5 6.7.4 Flush-mounted in metal = 150 mm Figure 6-31 6.7.5 Metal-free area for ANT D5 Minimum spacing Note Extension of the data transmission time if distance values are undershot If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from transponder to transponder (without multitag mode) RF290R MDS D100 / MDS D126 / MDS D139 / MDS D165 / MDS D200 / MDS D261 / MDS D339 / MDS D400 / MDS D426 / MDS D526 MDS D124 / MDS D160 / MDS D324 / MDS D424 / MDS D428 / MDS D460 / MDS D524 / MDS D528 / MDS D560 ≥1m ≥ 0.8 m SIMATIC RF200 194 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.7 ANT D5 Minimum distances from antenna to antenna RF290R with ANT D5 RF290R with ANT D6 RF290R with ANT D10 RF290R with ANT D5 ≥2m ≥2m ≥2m RF290R with ANT D6 ≥2m ≥2m ≥2m RF290R with ANT D10 ≥2m ≥2m ≥2m Definition of distance D Figure 6-32 6.7.6 Distance D: ANT D5 Technical data 6GT2698-5AA10 Product type designation ANT D5 Electrical data Maximum write/read distance ANT ↔ transponder 500 mm (Sg) Interfaces Plug connection 1-pin TNC plug Mechanical specifications Housing • Material • Aluminum/plastic SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 195 Antennas 6.7 ANT D5 6GT2698-5AA10 • Color • gray/black Permitted ambient conditions Ambient temperature • During operation • -20 °C ... +55 °C • During transportation and storage • -25 ℃ ... +70 ℃ Degree of protection to EN 60529 IP65 (UL: for indoor use only) Shock according to EN 60721-3-7 Class 7 M31) Vibration according to EN 60721-3-7 Class 7 M31) 300 m/s2 • 10 m/s2 (9 ... 200 Hz) • 15 m/s2 (200 ... 500 Hz) Design, dimensions and weight Dimensions (L x W x H) 380 x 380 x 110 mm Weight 1.2 kg Type of mounting 4x M6 or alternatively M8 screws Cable length 3.3 m 1) Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 196 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.7 ANT D5 6.7.7 Dimension drawing Figure 6-33 Dimension drawing for ANT D5 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 197 Antennas 6.8 ANT D6 6.8 ANT D6 6.8.1 Features ANT D6 Characteristics Area of application 6.8.2 • Storage, logistics and distribution • Suitable for high-speed applications with large writing/reading distance Writing/reading distance up to 650 mm (depending on the transponder) Connecting cable 3.3 m; included in scope of supply Cover Available as accessory Readers that can be connected RF290R Degree of protection IP65 (also without cover) Ordering data Table 6- 23 ANT D6 ordering data Antenna Article number ANT D6 (without cover, incl. one antenna connecting cable 3.3 m) 6GT2698-5AB00 Table 6- 24 Ordering data for ANT D6 accessories Accessories Article number Covering hood for ANT D6 6GT2690-0AD00 Antenna splitter (incl. one antenna connecting cable 3.3 m) 6GT2690-0AC00 Antenna multiplexer (incl. one antenna connecting cable 0.4 m) 6GT2894-0EA00 Antenna cable Antenna extension cable, length 7.2 m Length 3.3 m 6GT2691-0CH33 Length 10.5 m 6GT2691-0CN10 6GT2691-0DH72 SIMATIC RF200 198 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.8 ANT D6 6.8.3 Transmission window Lx = 520 mm Ly = 420 mm Figure 6-34 Transmission window for ANT D6 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 199 Antennas 6.8 ANT D6 6.8.4 Metal-free area Flush-mounted in metal Figure 6-35 6.8.5 Metal-free area for ANT D6 Minimum spacing Definition of distance D Figure 6-36 Distance D: ANT D6 SIMATIC RF200 200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.8 ANT D6 6.8.6 Technical data 6GT2698-5AB00 Product type designation ANT D6 Electrical data Maximum write/read distance ANT ↔ transponder 650 mm (Sg) Interfaces Plug connection 1-pin TNC plug Mechanical specifications Housing • Material • Aluminum/plastic • Color • gray/black Permitted ambient conditions Ambient temperature • During operation • -20 °C ... +55 °C • During transportation and storage • -25 ℃ ... +70 ℃ Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7 IP65 (UL: for indoor use only) M31) 300 m/s2 Vibration according to EN 60721-3-7 Class 7 M31) • • 10 m/s2 (9 ... 200 Hz) 15 m/s2 (200 ... 500 Hz) Design, dimensions and weight Dimensions (L x W x H) 580 x 480 x 110 mm Weight 3.3 kg (without cover) SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 201 Antennas 6.8 ANT D6 6GT2698-5AB00 Type of mounting 4 x M6 screws Cable length 3.3 m 1) 6.8.7 Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimensional diagram Figure 6-37 Dimension drawing for ANT D6 SIMATIC RF200 202 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.9 ANT D10 6.9 ANT D10 6.9.1 Features ANT D10 Characteristics Area of application 6.9.2 • Storage, logistics and distribution, e.g. clothing industry, laundries • Particularly when small MDS are used (e.g. MDS D124, MDS D160) and when there is a long transmission field Writing/reading distance up to 480 mm (depending on the transponder) Connecting cable 3.3 m; included in scope of supply Cover Included in scope of supply Readers that can be connected RF290R Ordering data Table 6- 25 Ordering data of ANT D10 Antenna Article number ANT D10 (incl. cover and one antenna connecting cable 3.3 m) 6GT2698-5AF00 Table 6- 26 Ordering data of ANT D10 accessories Accessories Article number Antenna splitter (incl. one antenna connecting cable 3.3 m) 6GT2690-0AC00 Antenna multiplexer (incl. one antenna connecting cable 0.4 m) 6GT2894-0EA00 Antenna cable Antenna extension cable, length 7.2 m Length 3.3 m 6GT2691-0CH33 Length 10.5 m 6GT2691-0CN10 6GT2691-0DH72 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 203 Antennas 6.9 ANT D10 6.9.3 Transmission window Lx 1050 mm Ly 350 mm Figure 6-38 Transmission window for ANT D10 SIMATIC RF200 204 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.9 ANT D10 6.9.4 Metal-free area Flush-mounted in metal Figure 6-39 Metal-free area for ANT D10 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 205 Antennas 6.9 ANT D10 6.9.5 Minimum spacing Definition of distance D Figure 6-40 6.9.6 Distance D: ANT D10 Technical data 6GT2698-5AF00 Product type designation ANT D10 Electrical data Maximum write/read distance ANT ↔ transponder 480 mm (Sg) Interfaces Plug connection 1-pin TNC plug Mechanical specifications Housing • Material • Aluminum/plastic • Color • gray/black Permitted ambient conditions Ambient temperature • During operation • -20 °C ... +55 °C • During transportation and storage • -25 ℃ ... +70 ℃ Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7 IP65 (UL: for indoor use only) M31) 300 m/s2 SIMATIC RF200 206 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Antennas 6.9 ANT D10 6GT2698-5AF00 Vibration according to EN 60721-3-7 Class 7 M31) • • 10 m/s2 (9 ... 200 Hz) 15 m/s2 (200 ... 500 Hz) Design, dimensions and weight Dimensions (L x W x H) 1150 x 365 x 115 mm (with cover) Weight 10 kg Type of mounting 4 x M6 screws Cable length 3.3 m 1) Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 207 Antennas 6.9 ANT D10 6.9.7 Dimensional diagram Figure 6-41 Dimension drawing for ANT D10 SIMATIC RF200 208 System Manual, 07/2017, J31069-D0227-U001-A9-7619 7 Transponder 7.1 Memory configuration of ISO the transponders Figure 7-1 Memory configuration of ISO the transponders SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 209 Transponder 7.2 MDS D100 Memory areas Depending on the manufacturer of the transponder chip, the memory configuration of an ISO transponder consists of varying sizes of user memory. The typical sizes are 112 bytes, 256 bytes, 992 bytes EEPROM or 2000 bytes, 8192 bytes FRAM. Each ISO transponder chip has an 8-byte long unique serial number (UID, read only). This UID is transferred as an 8 byte value through a read command to address FFF0 with a length of 8. Note OPT memory The transponders have an OTP memory. This was previously only supported by the RF300 readers. 7.2 MDS D100 7.2.1 Characteristics MDS D100 7.2.2 Characteristics Area of application From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. Memory size 112 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 7- 1 Ordering data for MDS D100 Article number MDS D100 6GT2600-0AD10 SIMATIC RF200 210 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.2 MDS D100 Table 7- 2 Ordering data for MDS D100 accessory Article number 7.2.3 Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 Metal-free area Direct mounting of the MDS D100 on metal is not allowed. A distance of ≥ 20 mm is recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with the fixing pocket 6GT2190-0AB00. Mounting on metal ① ② ③ ≥ 20 mm Transponder Metal Non-metal Figure 7-2 Mounting of the MDS D100 on metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 211 Transponder 7.2 MDS D100 Flush-mounting ≥ 20 mm ≥ 20 mm ① ② ③ Transponder Metal Non-metal Figure 7-3 Flush-mounting of MDS D100 in metal with spacer Note If the minimum guide values (h or a) are not observed, a reduction of the field data results. 7.2.4 Technical data Table 7- 3 Technical specifications for MDS D100 6GT2600-0AD10 Product type designation SIMATIC MDS D100 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) SIMATIC RF200 212 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.2 MDS D100 6GT2600-0AD10 Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PET • Color • White/black Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +80 ℃ • outside the read/write field • -25 to +80 ℃ • during storage • -25 to +80 ℃ Degree of protection to EN 60529 IP68 Shock-resistant to EN 60721-3-7 class 7M3 ISO 10373 / ISO 7810 1) Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85.6 x 54 x 0.9 mm Weight 5g Type of mounting • Fixing pocket • Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 213 Transponder 7.2 MDS D100 7.2.5 Dimension drawing Dimensions in mm 1) Dimensions for mounting holes Figure 7-4 MDS D100 dimension drawing SIMATIC RF200 214 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.3 MDS D117 7.3 MDS D117 7.3.1 Features MDS D117 7.3.2 Characteristics Area of application Very compact data carrier that can be cemented into objects where precise positioning is necessary; e.g. tool identification, workpiece holders etc.. Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data (Page 39)." Mounting in metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 4 Ordering data for MDS D117 Article number MDS D117 6GT2600-0AG00 Pack of 10 7.3.3 Mounting in metal Flush-mounted in metal ① Transponder ② Metal SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 215 Transponder 7.3 MDS D117 7.3.4 Technical specifications Table 7- 5 Technical specifications for MDS D117 6GT2600-0AG00 Product type designation SIMATIC MDS D117 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +125 ℃ • during storage • -40 to +125 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class Torsion and bending load 7M31) 1000 m/s2 200 m/s2 Not permitted Design, dimensions and weight Dimensions (Ø x H) 4 x 5.2 mm SIMATIC RF200 216 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.4 MDS D124 6GT2600-0AG00 7.3.5 Weight 1g Type of mounting • Fixing pocket • Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Figure 7-5 Dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 217 Transponder 7.4 MDS D124 7.4 MDS D124 7.4.1 Characteristics MDS D124 7.4.2 Characteristics Area of application Application areas in production automation (e.g. small paintshops up to +180 °C) Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data (Page 39)". Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 6 Ordering data for MDS D124 Article number MDS D124 Table 7- 7 6GT2600-0AC10 Ordering data for MDS D124 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF200 218 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.4 MDS D124 7.4.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 7-6 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 7-7 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 219 Transponder 7.4 MDS D124 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 7.4.4 Technical specifications Table 7- 8 Technical specifications for MDS D124 6GT2600-0AC10 Product type designation SIMATIC MDS D124 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • • during write/read access outside the read/write field • -25 … +140 °C • from +125 ℃: 20% reduction in the limit distance • -40 to +180 ℃ SIMATIC RF200 220 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.4 MDS D124 6GT2600-0AC10 • during storage Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class 7M31) Torsion and bending load • at +180 ℃: Tested up to 5000 hours or 3000 cycles • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C 1000 m/s2 200 m/s2 Not permitted Design, dimensions and weight 7.4.5 Dimensions (Ø x H) 4 x 5.2 mm Weight 5g Type of mounting • 1 x M3 screw 2) ≤ 1 Nm • Glued 3) • With spacer 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 3) The processing instructions of the adhesive manufacturer must be observed. Use of the MDS D124 in hazardous area The mobile data memory MDS D124, device group II, category 1G or 1D may be installed and operated in zones 0, 1 and 2 or in the zones 20, 21 and 22. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2009 ● EN 60079-11:2007 ● EN 61241-11:2006 ● EN 60079-26:2007 When used in hazardous areas, the MDS D124 must not be operated with field strengths > 5 A / m to avoid impermissible heating. This is not the case with readers from the SIMATIC RF range (MOBY D, RF200 and RF300). SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 221 Transponder 7.4 MDS D124 Identification II 1 G Ex ia IIC T3 to T6 Ga or II 1 D Ex ia IIIC T80 °C to T180 °C Da TÜV 12 ATEX 084413 X The temperature class or the maximum surface temperature depends on the maximum ambient temperature. The relationship between temperature class (gas) or maximum surface temperature (dust) can be found in the following table. Table 7- 9 Ambient temperature Ambient temperature range Temperature class Max. surface temperature -25 ... +150 ℃ T3 T180 -25 ... +100 ℃ T4 T130 -25 ... +65 ℃ T5 T95 -25 ... +50 ℃ T6 T80 Note Safety markings for hazardous areas Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a label with the device. This must be affixed immediately next to the MDS D124 so that the label clearly relates to the device. WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques SIMATIC RF200 222 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.4 MDS D124 Note Installation and operating conditions for hazardous areas: • Use of the device in the vicinity of processes generating high charges is not allowed. • The device must be installed so that it is mechanically protected. • For applications requiring devices of category 1, the device must be mounted on a grounded, conductive base. • It must only be cleaned with a damp cloth. • The device is suitable for use in atmospheres containing dust, however not for full immersion in dust. 7.4.6 Dimension drawing Figure 7-8 Dimension drawing of MDS D124 All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 223 Transponder 7.5 MDS D126 7.5 MDS D126 7.5.1 Characteristics MDS D126 7.5.2 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 112 bytes of EEPROM user memory Write/read range See section Field data (Page 39) Mounting on metal Yes, with spacer ISO standard ISO-15693 Degree of protection IP68 Ordering data Table 7- 10 Ordering data for MDS D126 Article number MDS D126 Table 7- 11 6GT2600-0AE00 Ordering data for MDS D126 accessories Article number Spacer 6GT2690-0AL00 SIMATIC RF200 224 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.5 MDS D126 7.5.3 Mounting on metal Mounting on metal ≥ 25 mm Figure 7-9 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 7-10 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 225 Transponder 7.5 MDS D126 7.5.4 Technical specifications Table 7- 12 Technical specifications for the MDS D126 6GT2600-0AE00 Product type designation SIMATIC MDS D126 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PA6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class Torsion and bending load 7M31) 500 m/s2 200 m/s2 Not permitted Design, dimensions and weight Dimensions (Ø x H) 50 x 3.6 mm SIMATIC RF200 226 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.5 MDS D126 6GT2600-0AE00 7.5.5 Weight 13 g Type of mounting • 1 x M4 screw 2) ≤ 1 Nm • Glued 3) 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 3) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Dimensions in mm Figure 7-11 Dimension drawing of MDS D126 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 227 Transponder 7.6 MDS D127 7.6 MDS D127 7.6.1 Features MDS D127 7.6.2 Characteristics Area of application Very compact data carrier that can be screwed into areas where precise positioning is necessary; e.g. tool identification, workpiece holders etc. Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 13 Ordering data for MDS D127 Article number MDS D127 6GT2600-0AF00 Pack of 10 (A screw-in aid is supplied with each pack) SIMATIC RF200 228 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.6 MDS D127 7.6.3 Mounting in metal Flush-mounted in metal ① Metal ② Transponders Note Damage to the transponder due to improper mounting To screw the MDS D127 into a suitable thread, use the supplied screw-in tool. This avoids damage to the MDS D127. Figure 7-12 Screw-in aid for mounting the MDS D127 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 229 Transponder 7.6 MDS D127 7.6.4 Technical specifications Table 7- 14 Technical specifications for MDS D127 6GT2600-0AF00 Product type designation SIMATIC MDS D127 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PA6 • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +100 ℃ • outside the read/write field • -40 to +125 ℃ • during storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class Torsion and bending load 7M31) 1000 m/s2 200 m/s2 Not permitted SIMATIC RF200 230 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.6 MDS D127 6GT2600-0AF00 Design, dimensions and weight Dimensions (Ø x H) M6 x 5.8 mm Weight 1g Type of mounting • Glued 2) • 1 x M3 screw 1) 2) 7.6.5 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Figure 7-13 Dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 231 Transponder 7.7 MDS D139 7.7 MDS D139 7.7.1 Characteristics MDS D139 Characteristics Area of application Applications in production logistics and in assembly lines subject to high temperatures (up to +220 °C) Typical application areas: 7.7.2 • Paintshops and their preparatory treatments) • Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces • Top coat area with drying furnaces • Washing areas at temperatures > 85 °C • Other applications with higher temperatures Memory size 112 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 15 Ordering data for MDS D139 Article number MDS D139 Table 7- 16 6GT2600-0AA10 Ordering data for MDS D139 accessory Article number Spacer 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 60 mm 6GT2690-0AH00 Quick change holder (Ø x H): 22 x 47 mm 6GT2690-0AH10 SIMATIC RF200 232 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.7 MDS D139 7.7.3 Metal-free area Direct mounting of the MDS D139 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers (see "Transponder holders (Page 355)"). Mounting on metal ≥ 30 mm Figure 7-14 Mounting the MDS D139 on metal with spacer Flush-mounting It is possible to mount the MDS D139 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. ≥ 30 mm ≥ 100 mm Figure 7-15 Flush-mounting of the MDS D139 in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 233 Transponder 7.7 MDS D139 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications. 7.7.4 Mounting in metal It is possible to mount the MDS D139 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. = 100 mm = 30 mm Figure 7-16 7.7.5 MDS D139: Mounting in metal Cleaning the transponder NOTICE Cleaning the transponder Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the chemical cleansing agents listed in the section Chemical resistance of the reader and transponders (Page 89). SIMATIC RF200 234 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.7 MDS D139 7.7.6 Technical specifications Table 7- 17 Technical specifications for MDS D139 6GT2600-0AA10 Product type designation SIMATIC MDS D139 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 30 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • • • during write/read access outside the read/write field during storage • -25 … +140 °C • from +125 ℃: 20% reduction in the limit distance • -40 to +220 ℃ • at +200 ℃: Tested up to 5000 hours or 6000 cycles • at +220 ℃: Tested up to 2000 hours or 2000 cycles • -40 to +100 ℃ SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 235 Transponder 7.7 MDS D139 6GT2600-0AA10 Degree of protection to EN 60529 • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock according to EN 60721-3-7 Class 7M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.7.7 Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 2) 1.5 Nm The values for shock and vibration are maximum values and must not be applied continuously. 2) For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). Use of the MDS D139 in hazardous areas The MDS D139 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2006 ● EN 60079-15:2005 ● EN 61241-0:2006 ● EN 61241-1:2004 SIMATIC RF200 236 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.7 MDS D139 Identification II 3 G Ex nA II T2 II 3 D Ex tD A22 IP68 T 220°C KEMA 09 ATEX 0133 X Ta: -25 ... +220°C WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques Note Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen. Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 237 Transponder 7.7 MDS D139 7.7.8 Dimension drawings Dimensional drawing of MDS D139 Figure 7-17 Dimensional drawing of MDS D139 Dimensions in mm SIMATIC RF200 238 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.8 MDS D160 7.8 MDS D160 7.8.1 Characteristics MDS D160 Characteristics Area of application Thanks to its rugged packaging, the MDS D160 is a transponder that can be used under extreme environmental conditions. It is washable, heat-resistant and resistant to all chemicals generally used in the laundry process. Typical applications are, for example: 7.8.2 • Rented work clothing • Hotel laundry • Surgical textiles • Hospital clothing • Dirt collection mats • Clothing for nursing homes/hostels Memory size 112 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 18 Ordering data for MDS D160 Article number MDS D160 Table 7- 19 6GT2600-0AB10 Ordering data for MDS D160 accessories Article number Spacer 6GT2690-0AG00 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 239 Transponder 7.8 MDS D160 7.8.3 Mounting on metal Mounting on metal ① ② ③ Transponder ≥ 10 mm Metal carrier Spacer Figure 7-18 Mounting the MDS D160 on metal with spacer Note Going below the minimum distance (h) If the minimum distance (h) is not observed, a reduction of the field data results. In critical applications, it is recommended that a test is performed. Flush-mounting Flush-mounting of the MDS D160 in metal is not permitted! 7.8.4 Technical specifications Table 7- 20 Technical specifications for the MDS D160 6GT2600-0AB10 Product type designation SIMATIC MDS D160 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM SIMATIC RF200 240 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.8 MDS D160 6GT2600-0AB10 • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • beige Recommended distance to metal ≥ 10 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 … +85 °C • outside the read/write field • -40 … +175 °C • from +125 ℃: for 1000 hours, 20% reduction of the limit distance • at +175 ℃: 100 washing cycles tested • at +220 ℃: Tested once for up to 30 seconds • -25 to +100 ℃ • during storage Mechanical strength • Isostatic pressure • 300 bar for 5 min • Axial pressure • 1000 N for 10 s • Radial pressure • 1000 N for 10 s Resistance to chemicals All chemicals normally used in the washing process MDS lifespan At least 100 wash cycles Degree of protection • IP68 24 hours, 2 bar, +20 °C • IPx9K Shock according to IEC 68-2-271) 400 m/s2 18 ms; 6 axes; 2000 repetitions/h Vibration according to IEC 68-2-61) 100 m/s2 10 ... 2000 Hz; 3 axes; 2.5 h SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 241 Transponder 7.8 MDS D160 6GT2600-0AB10 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight 1.2 g Type of mounting • Patched • Sewn in • Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Note Regeneration time between washing cycles The regeneration time for the MDS D160 between washing cycles must be at least 24 hours. 7.8.5 Dimension drawings Dimensional drawing of MDS D160 Dimensions in mm Figure 7-19 Dimensional drawing of MDS D160 SIMATIC RF200 242 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.9 MDS D165 Dimensional drawing of spacer Dimensions in mm Figure 7-20 7.9 MDS D165 7.9.1 Features Dimensional drawing of spacer MDS D165 (special version) Characteristics Area of application The design of the transponder (self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications. From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. 7.9.2 Memory size 112 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP65 Ordering data Table 7- 21 Ordering data for MDS D165 Article number MDS D165 (special version ISO-CARD) 6GT2600-1AB00-0AX0 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 243 Transponder 7.9 MDS D165 Type of delivery Minimum order quantity: 1250 units (5 rolls with 250 units each) 7.9.3 Technical data Table 7- 22 Technical specifications for MDS D165 6GT2600-1AB00-0AX0 Product type designation SIMATIC MDS D165 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • • Material Color • Top • PET plastic (label material) • Inlay • PET plastic (carrier material) • Antenna • Aluminum • Bottom • Double-sided transfer adhesive on silicon paper • White Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 ... +80 °C SIMATIC RF200 244 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.9 MDS D165 6GT2600-1AB00-0AX0 • outside the read/write field • • during storage • +20 to +30 ℃ Can be stored for 2 years, determined by the durability of the adhesive. Degree of protection -25 to +80 ℃ IP65 Design, dimensions and weight Dimensions (L x W x H) 86 x 54 x 0.3 mm Weight 1g Type of mounting Glued with self-adhesive label 1) 1) 7.9.4 The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Dimensions in mm Figure 7-21 Dimension drawing of MDS D165 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 245 Transponder 7.10 MDS D200 7.10 MDS D200 7.10.1 Features MDS D200 7.10.2 Characteristics Area of application From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. Memory size 256 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard 15693 with Tag-it HFI technology Degree of protection IP67 Ordering data Table 7- 23 Ordering data for MDS D200 Article number MDS D200 (special version ISO-CARD) Table 7- 24 6GT2600-1AD00-0AX0 Ordering data for MDS D200 accessories Article number Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 SIMATIC RF200 246 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.10 MDS D200 7.10.3 Mounting on metal Mounting on metal ① ② ③ ≥ 20 mm Transponder Metal Non-metal Figure 7-22 Mounting of the MDS D200 on metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 247 Transponder 7.10 MDS D200 Flush-mounting ≥ 20 mm ≥ 20 mm ① ② ③ Transponder Metal Non-metal Figure 7-23 Flush-mounting of MDS D200 in metal with spacer Note If the minimum guide values (h) are not observed, a reduction of the field data results. 7.10.4 Technical data Table 7- 25 Technical specifications for MDS D200 6GT2600-1AD00-0AX0 Product type designation SIMATIC MDS D200 Memory Memory configuration • UID • 8 bytes • User memory • 256 bytes EEPROM SIMATIC RF200 248 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.10 MDS D200 6GT2600-1AD00-0AX0 • OTP memory • 16 bytes (EEPROM) Read cycles (at < 25 ℃) > 1014 Write cycles (at < 25 ℃) > 106 Data retention time (at < 25 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PET • Color • White Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -20 to +60 ℃ • outside the read/write field • -20 to +60 ℃ • during storage • -20 to +60 ℃ Degree of protection to EN 60529 IP67 Shock-resistant to EN 60721-3-7 class 7M3 ISO 10373 / ISO 7810 1) Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85 x 54 x 0.8 mm Weight 5g Type of mounting • Fixing pocket • Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 249 Transponder 7.11 MDS D261 7.10.5 Dimension drawing Dimensions in mm Figure 7-24 7.11 MDS D261 7.11.1 Features Dimension drawing of MDS D200 MDS D261 Characteristics Area of application The design of the transponder (self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications. From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. 7.11.2 Memory size 256 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP65 Ordering data Table 7- 26 Ordering data for MDS D261 Article number MDS D261 6GT2600-1AA00-0AX0 SIMATIC RF200 250 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.11 MDS D261 Type of delivery Minimum order quantity: 1250 units (5 rolls with 250 units each) 7.11.3 Technical data Table 7- 27 Technical specifications of MDS D261 6GT2600-1AA01-0AX0 Product type designation SIMATIC MDS D261 Memory Memory configuration • UID • 8 bytes • User memory • 256 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • • Material Color • Top • PET plastic (label material) • Inlay • PET plastic (carrier material) • Antenna • Aluminum • Bottom • Double-sided transfer adhesive on silicon paper • White Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -20 ... +60 °C SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 251 Transponder 7.11 MDS D261 6GT2600-1AA01-0AX0 • outside the read/write field • • During transportation and storage • +20 to +30 ℃ Can be stored for 2 years, determined by the durability of the adhesive Degree of protection -20 … +85 °C IP65 Design, dimensions and weight Dimensions (L x W x H) 55 x 55 x 0.3 mm Weight 1g Type of mounting Glued with self-adhesive label 1) 1) 7.11.4 The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Dimensions in mm Figure 7-25 Dimension drawing of MDS D261 SIMATIC RF200 252 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.12 MDS D324 7.12 MDS D324 7.12.1 Characteristics MDS D324 Characteristics Area of application Production and distribution logistics and product identification Can also be used in harsh environments under extreme environmental conditions (e.g. with higher temperature load). 7.12.2 Memory size 992 bytes of EEPROM user memory Write/read range See section "Field data (Page 39)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K Ordering data Table 7- 28 Ordering data MDS D324 Article number MDS D324 Table 7- 29 6GT2600-3AC00 Ordering data MDS D324 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 253 Transponder 7.12 MDS D324 7.12.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 7-26 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 7-27 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF200 254 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.12 MDS D324 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 7.12.4 Technical specifications Table 7- 30 Technical specifications of MDS D324 6GT2600-3AC00 Product type designation SIMATIC MDS D324 Memory Memory configuration • UID • 8 bytes • User memory • 992 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +125 ℃ • outside the read/write field • -40 to +140 ℃ • during storage • -40 to +140 ℃ SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 255 Transponder 7.12 MDS D324 6GT2600-3AC00 Degree of protection to EN 60529 • IP67 • IPx9K Shock according to EN 60721-3-7 Class 7M31) 1000 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.12.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • 1 x M3 screw 2) ≤ 1 Nm • Glued 3) 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 3) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Figure 7-28 Dimension drawing of MDS D324 All dimensions in mm SIMATIC RF200 256 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.13 MDS D339 7.13 MDS D339 7.13.1 Characteristics MDS D339 Characteristics Area of application Applications in production automation with high temperature demands (up to +220 °C) Typical application areas: 7.13.2 • Paintshops and their preparatory treatments • Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces • Top coat area with drying furnaces • Washing areas at temperatures > 85 °C • Other applications with higher temperatures Memory size 992 bytes of EEPROM user memory Write/read range See section Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 31 Ordering data for MDS D339 Article number MDS D339 Table 7- 32 6GT2600-3AA10 Ordering data for MDS D339 accessories Article number Spacer 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 60 mm 6GT2690-0AH00 Quick change holder (Ø x H): 22 x 47 mm 6GT2690-0AH10 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 257 Transponder 7.13 MDS D339 7.13.3 Mounting on metal Direct mounting of the MDS D139/D339 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers (see "Transponder holders (Page 355)"). Mounting on metal ≥ 30 mm Figure 7-29 Mounting the MDS D139/D339 on metal with spacer Flush-mounting It is possible to mount the MDS D139/D339 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. ≥ 30 mm ≥ 100 mm Figure 7-30 Flush-mounting of the MDS D139/D339 in metal with spacer SIMATIC RF200 258 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.13 MDS D339 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications. 7.13.4 Mounting in metal It is possible to mount the MDS D339 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. = 100 mm = 30 mm Figure 7-31 7.13.5 MDS D339: Mounting in metal Cleaning the transponder NOTICE Cleaning the transponder Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the chemical cleansing agents listed in the section Chemical resistance of the reader and transponders (Page 89). SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 259 Transponder 7.13 MDS D339 7.13.6 Technical specifications Table 7- 33 Technical specifications of MDS D339 6GT2600-3AA10 Product type designation SIMATIC MDS D339 Memory Memory configuration • UID • 8 bytes • User memory • 992 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 30 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +100 ℃ • outside the read/write field • -40 to +220 ℃ • from +125 ℃: 20% reduction in the limit distance • at +200 ℃: Tested up to 5000 hours or 6000 cycles • at +220 ℃: Tested up to 2000 hours or 2000 cycles • -40 to +100 ℃ • during storage SIMATIC RF200 260 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.13 MDS D339 6GT2600-3AA10 Degree of protection to EN 60529 • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock according to EN 60721-3-7 Class 7M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.13.7 Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 2) 1.5 Nm The values for shock and vibration are maximum values and must not be applied continuously. 2) For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). Use of the MDS D339 in hazardous areas The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2006 ● EN 60079-15:2005 ● EN 61241-0:2006 ● EN 61241-1:2004 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 261 Transponder 7.13 MDS D339 Identification II 3 G Ex nA II T6 Ii 3 D Ex tD A22 IP68 T 210°C KEMA 09 ATEX 0133 X WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques Note Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen. Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide SIMATIC RF200 262 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.13 MDS D339 7.13.8 Dimensional drawing MDS D339 Figure 7-32 Dimension drawing of the MDS D339 Dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 263 Transponder 7.14 MDS D400 7.14 MDS D400 7.14.1 Features MDS D400 7.14.2 Characteristics Area of application Simple identification such as electronic barcode replacement/supplements, from warehouse and distribution logistics right through to product identification. Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67 Ordering data Table 7- 34 Ordering data of MDS D400 Article number MDS D400 Table 7- 35 6GT2600-4AD00 Ordering data of MDS D400 accessories Article number Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 SIMATIC RF200 264 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.14 MDS D400 7.14.3 Mounting on metal Mounting on metal It is possible to mount the MDS D400 on metal. ① ② ③ ≥ 20 mm Transponder Metal Non-metal Figure 7-33 Mounting of the MDS D400 on metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 265 Transponder 7.14 MDS D400 Flush-mounted in metal ≥ 20 mm ≥ 20 mm ① ② ③ Transponder Metal Non-metal Figure 7-34 Flush-mounting of MDS D400 in metal with spacer Note If the minimum guide values (h) are not observed, this will result in a reduction of the field data. 7.14.4 Technical specifications Table 7- 36 Technical specifications for MDS D400 6GT2600-4AD00 Product type designation SIMATIC MDS D400 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM SIMATIC RF200 266 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.14 MDS D400 6GT2600-4AD00 • OTP memory • 16 bytes FRAM Read cycles (at < 25 ℃) > 1012 Write cycles (at < 25 ℃) > 1012 Data retention time (at < 25 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PVC • Color • White Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -20 to +60 ℃ • outside the read/write field • -20 to +60 ℃ • during storage • -20 to +60 ℃ Degree of protection to EN 60529 IP67 Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85 x 54 x 0.8 mm Weight 5g Type of mounting • Fixing lug • Glued 2) 1) The values for vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 267 Transponder 7.14 MDS D400 7.14.5 Dimension drawing Figure 7-35 Dimensional drawing MDS D400 (dimensions in mm) SIMATIC RF200 268 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.15 MDS D421 7.15 MDS D421 7.15.1 Characteristics MDS D421 Characteristics Area of application The MDS D421 is designed for tool coding in accordance with DIN 69873. It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders. The rugged housing of the MDS D421 means that it can also be used in a harsh industrial environment without problems. 7.15.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP67/IPx9K Ordering data Table 7- 37 Ordering data of MDS D421 Article number MDS D421 6GT2600-4AE00 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 269 Transponder 7.15 MDS D421 7.15.3 Mounting on metal Mounting on metal Figure 7-36 Mounting of MDS D421 on metal Figure 7-37 Mounting of MDS D421 in metal Flush-mounting Flush-mounting of MDS D421 in metal with tools Figure 7-38 Flush-mounting of MDS D421 in metal with tools SIMATIC RF200 270 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.15 MDS D421 b1 0.5 x 45° b2 0.3 x 45° or R 0.3 d1 10 (-0.04.. -0.13) d2 10 (+0.09... 0) t1 4.5 (-0... -0.1) t2 4.6 (+0.2... 0) All dimensions in mm Note Installation instruction The MDS should not protrude out of the locating hole; it must be flush with the outside contour. The mounting instructions of the MDS and the conditions associated with the application (e.g. peripheral speed, temperature, and use of coolant) must be observed during the installation. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D421 using your finger; antenna side to the outside (see figure "Flushmounting of MDS D421 in metal with tools") ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D421 in metal with tools Installation examples Figure 7-39 Installation example of MDS D421 in a steep cone SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 271 Transponder 7.15 MDS D421 Figure 7-40 7.15.4 Installation example of MDS D421 in a stud bolt Technical specifications Table 7- 38 Technical specifications for the MDS D421 6GT2600-4AE00 Product type designation SIMATIC MDS D421 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ SIMATIC RF200 272 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.15 MDS D421 6GT2600-4AE00 Degree of protection to EN 60529 • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock according to EN 60721-3-7 Class 7M31) 1000 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.15.5 Dimensions (Ø x H) 10 x 4.5 mm Weight Approx. 1 g Type of mounting Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Figure 7-41 Dimension drawing of MDS D421 All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 273 Transponder 7.16 MDS D422 7.16 MDS D422 7.16.1 Characteristics MDS D422 7.16.2 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39). Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 7- 39 Ordering data of MDS D422 Article number MDS D422 6GT2600-4AF00 A screw-in aid is included in the scope of supply per packaging unit 7.16.3 Mounting in metal Flush-mounting Figure 7-42 Mounting of MDS D422 in metal SIMATIC RF200 274 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.16 MDS D422 Mounting information for screws You can screw the transponder into a pre-drilled threaded hole using the screw-in aid. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D422 using your fingers; with antenna to the outside ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D422 in metal with tools 7.16.4 Technical specifications Table 7- 40 Technical specifications for the MDS D422 6GT2600-4AF00 Product type designation SIMATIC MDS D422 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 285 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF; brass nickel plated • Color • Black/silver Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 275 Transponder 7.16 MDS D422 6GT2600-4AF00 Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to EN 60721-3-7 Class 7M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.16.5 Dimensions (Ø x H) 20 x 6 mm Weight 13 g Type of mounting • Glued 2) • 1 x transponder thread M20 ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Dimensions in mm Figure 7-43 Dimensional drawing of MDS D422 SIMATIC RF200 276 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.17 MDS D423 7.17 MDS D423 7.17.1 Characteristics MDS D423 7.17.2 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers, production automation Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 41 Ordering data of MDS D423 Article number MDS D423 Table 7- 42 6GT2600-4AA00 Ordering data of MDS D423 accessories Article number Fixing hood RF330T / MDS D423 7.17.3 6GT2690-0AE00 Mounting on metal Mounting on metal Direct mounting of the MDS D423 on metal is possible. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 277 Transponder 7.17 MDS D423 Figure 7-44 Mounting the MDS D423 on metal Flush-mounted in metal It is possible to mount the MDS D423 in metal. ≥ 10 mm Figure 7-45 Flush-mounting of the MDS D423 in metal with 10 mm clearance SIMATIC RF200 278 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.17 MDS D423 Figure 7-46 Flush-mounting of the MDS D423 in metal without clearance Note Reduction of the write/read range Note that when the device is flush-mounted in metal without a surrounding clearance ≥ 10 mm, the write/read range is significantly reduced. 7.17.4 Technical specifications Table 7- 43 Technical specifications of MDS D423 6GT2600-4AA00 Product type designation SIMATIC MDS D423 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PPS SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 279 Transponder 7.17 MDS D423 6GT2600-4AA00 • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class Pressure resistance Torsion and bending load 7M31) 500 m/s2 200 m/s2 • Low pressure resistant vacuum dryer: up to 20 mbar • High pressure resistant (see degree of protection IPx9K) Not permitted Design, dimensions and weight Dimensions (Ø x H) 30 x 8 mm Weight 15 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. SIMATIC RF200 280 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.18 MDS D424 7.17.5 Dimensional drawing Dimensions in mm Figure 7-47 Dimension drawing for MDS D423 7.18 MDS D424 7.18.1 Characteristics MDS D424 Characteristics Area of application Production and distribution logistics as well as in assembly and production lines, can also be used in a harsh industrial environment without problem Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 281 Transponder 7.18 MDS D424 7.18.2 Ordering data Table 7- 44 Ordering data of MDS D424 Article number MDS D424 Table 7- 45 6GT2600-4AC00 Ordering data of MDS D424 accessories Article number Spacer 7.18.3 6GT2690-0AK00 Mounting on metal Mounting on metal ≥ 15 mm Figure 7-48 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer SIMATIC RF200 282 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.18 MDS D424 Flush-mounting ≥ 15 mm ≥ 25 mm Figure 7-49 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 7.18.4 Technical specifications Table 7- 46 Technical specifications for the MDS D424 6GT2600-4AC00 Product type designation SIMATIC MDS D424 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 283 Transponder 7.18 MDS D424 6GT2600-4AC00 Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ • IP67 • IPx9K Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7M31) Vibration according to EN 60721-3-7 Class Torsion and bending load 7M31) 1000 m/s2 200 m/s2 Not permitted Design, dimensions and weight Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • Glued 2) • 1x screw M3 3) ≤ 1 Nm 1) 2) The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. ) To prevent it loosening during operation, secure the screw with screw-locking varnish. SIMATIC RF200 284 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.19 MDS D425 7.18.5 Dimension drawing Figure 7-50 Dimension drawing of MDS D424 All dimensions in mm 7.19 MDS D425 7.19.1 Characteristics MDS D425 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting Use in assembly and production lines in the powertrain sector; ideal for mounting on motors, gearboxes, and workpiece holders Rugged packaging of the MDS D425; can therefore also be used under extreme environmental conditions without problem Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)". Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 285 Transponder 7.19 MDS D425 7.19.2 Ordering data Table 7- 47 Ordering data of MDS D425 Article number MDS D425 7.19.3 Application example Figure 7-51 7.19.4 6GT2600-4AG00 Application example Technical specifications Table 7- 48 Technical specifications for the MDS D425 6GT2600-4AG00 Product type designation SIMATIC MDS D425 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM SIMATIC RF200 286 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.19 MDS D425 6GT2600-4AG00 Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +125 ℃ • during storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to IEC 68-2-271) 500 m/s2 Vibration according to IEC 68-2-61) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 10 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M6 SW 22; ≤ 6 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 287 Transponder 7.20 MDS D426 7.19.5 Dimension drawing Dimensions in mm Figure 7-52 Dimension drawing of MDS D425 7.20 MDS D426 7.20.1 Characteristics MDS D426 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 2000 bytes of FRAM user memory Write/read range See section Field data (Page 39) Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 SIMATIC RF200 288 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.20 MDS D426 7.20.2 Mounting on metal Mounting on metal ≥ 25 mm Figure 7-53 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 7-54 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 289 Transponder 7.20 MDS D426 7.20.3 Ordering data Table 7- 49 Ordering data of MDS D426 Article number MDS D426 Table 7- 50 6GT2600-4AH00 Ordering data of MDS D426 accessories Article number Spacer 7.20.4 6GT2690-0AL00 Technical specifications Table 7- 51 Technical specifications for the MDS D426 6GT2600-4AH00 Product type designation SIMATIC MDS D426 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery SIMATIC RF200 290 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.20 MDS D426 6GT2600-4AH00 Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to IEC 68-2-271) 50 m/s2 Vibration according to IEC 68-2-61) 20 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.20.5 Dimensions (Ø x H) 50 x 3.6 mm Weight 13 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Dimensions in mm Figure 7-55 Dimension drawing of MDS D426 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 291 Transponder 7.21 MDS D428 7.21 MDS D428 7.21.1 Characteristics MDS D428 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting. Use in assembly and production lines in the powertrain sector. The rugged housing of the MDS D428 means that it can also be used in extreme environmental conditions without problems. 7.21.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 52 Ordering data of MDS D428 Article number MDS D428 6GT2600-4AK00-0AX0 SIMATIC RF200 292 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.21 MDS D428 7.21.3 Application example Figure 7-56 7.21.4 Application example Technical specifications Table 7- 53 Technical specifications for the MDS D428 6GT2600-4AK00 Product type designation SIMATIC MDS D428 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 293 Transponder 7.21 MDS D428 6GT2600-4AK00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +125 ℃ • during storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to IEC 68-2-271) 500 m/s2 Vibration according to IEC 68-2-61) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 20 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 294 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.22 MDS D460 7.21.5 Dimension drawing Dimensions in mm Figure 7-57 Dimension drawing of MDS D428 7.22 MDS D460 7.22.1 Characteristics MDS D460 Characteristics Area of application Identification in small assembly lines; can also be used in a harsh industrial environment Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data (Page 39). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67/IPx9K SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 295 Transponder 7.22 MDS D460 7.22.2 Ordering data Table 7- 54 Ordering data of MDS D460 Article number MDS D460 Table 7- 55 6GT2600-4AB00 Ordering data of MDS D460 accessories Article number Spacer 7.22.3 6GT2690-0AG00 Mounting on metal Mounting option on metal with spacer ① ② ③ Transponder ≥ 10 mm Metal Spacer Figure 7-58 Mounting the MDS D460 on metal with spacer Note If the minimum guide values (h) are not observed, a reduction of the field data results. In critical applications, it is recommended that a test is performed. Flush-mounting Flush-mounting of the MDS D460 in metal is not permitted! SIMATIC RF200 296 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.22 MDS D460 7.22.4 Technical specifications Table 7- 56 Technical specifications for MDS D460 6GT2600-4AB00 Product type designation SIMATIC MDS D460 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OTP memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 10 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to IEC 68-2-271) Vibration according to IEC 68-2-61) Torsion and bending load 500 m/s2 200 m/s2 Not permitted SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 297 Transponder 7.22 MDS D460 6GT2600-4AB00 Design, dimensions and weight 7.22.5 Dimensions (Ø x H) 16 x 3 mm Weight 3g Type of mounting • Glued 2) • With spacer 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Dimension drawings Dimensional drawing of MDS D460 Dimensions in mm Figure 7-59 Dimensional drawing of MDS D460 Dimensional drawing of spacer Dimensions in mm Figure 7-60 Dimensional drawing of spacer SIMATIC RF200 298 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.23 MDS D521 7.23 MDS D521 7.23.1 Characteristics MDS D521 Characteristics Area of application The MDS D521 is designed for tool coding according to DIN 69873. It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders. The rugged housing of the MDS D521 means that it can also be used in a harsh industrial environment without problems. 7.23.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP67/IPx9K Ordering data Table 7- 57 Ordering data for MDS D521 Article number MDS D521 7.23.3 6GT2600-5AE00 Mounting on metal Mounting on metal Figure 7-61 Mounting of MDS D521 on metal SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 299 Transponder 7.23 MDS D521 Flush-mounting Figure 7-62 Mounting of MDS D521 in metal Flush-mounting of MDS D521 in metal with tools Figure 7-63 Flush-mounting of MDS D521 in metal with tools b1 0.5 x 45° b2 0.3 x 45° or R 0.3 d1 10 (-0.04.. -0.13) d2 10 (+0.09... 0) t1 4.5 (-0... -0.1) t2 4.6 (+0.2... 0) All dimensions in mm Note Installation instruction The MDS should not protrude out of the locating hole; it must be flush with the outside contour. The mounting instructions of the MDS and the conditions associated with the application (e.g. peripheral speed, temperature, and use of coolant) must be observed during the installation. SIMATIC RF200 300 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.23 MDS D521 Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D521 using your finger; antenna side to the outside (see figure "Flushmounting of MDS D521 in metal with tools") ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D521 in metal with tools Installation examples 7.23.4 Figure 7-64 Installation example of MDS D521 in a steep cone Figure 7-65 Installation example of MDS D521 in a stud bolt Technical specifications Table 7- 58 Technical specifications for MDS D521 6GT2600-5AE00 Product type designation SIMATIC MDS D521 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 301 Transponder 7.23 MDS D521 6GT2600-5AE00 Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to EN 60721-3-7 Class 7M31) 1000 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 10 x 4.5 mm Weight 1g Type of mounting Glued 2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF200 302 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.24 MDS D522 7.23.5 Dimension drawing Figure 7-66 Dimension drawing of MDS D521 All dimensions in mm 7.24 MDS D522 7.24.1 Characteristics MDS D522 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers Memory size 8192 bytes of FRAM user memory Write/read range See "Field data (Page 39)." Mounting in metal Yes ISO standard ISO 15693 Degree of protection IP68 SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 303 Transponder 7.24 MDS D522 7.24.2 Ordering data Table 7- 59 Ordering data for MDS D522 Article number MDS D522 6GT2600-5AF00 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. 7.24.3 Mounting in metal Flush-mounting Figure 7-67 Mounting of MDS D522 in metal Mounting information for screws You can screw the transponder into a pre-drilled threaded hole using the screw-in aid. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D522 using your fingers; with antenna to the outside ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D522 in metal with tools SIMATIC RF200 304 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.24 MDS D522 7.24.4 Technical specifications Table 7- 60 Technical specifications for MDS D522 6GT2600-5AF00 Product type designation SIMATIC MDS D522 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 285 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF; brass nickel plated • Color • Black/silver Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to EN 60721-3-7 Class 7M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 20 x 6 mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 305 Transponder 7.24 MDS D522 6GT2600-5AF00 7.24.5 Weight 13 g Type of mounting • Glued 2) • 1 x transponder thread M20 ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. Dimension drawing Figure 7-68 Dimensional drawing of MDS D522 All dimensions in mm SIMATIC RF200 306 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.25 MDS D522 special variant 7.25 MDS D522 special variant 7.25.1 Characteristics MDS D522 special version 7.25.2 Characteristics Area of application Identification of metallic workpiece holders or workpieces Memory size 8192 bytes of FRAM user memory Write/read range See "Field data (Page 39)." Mounting in metal Yes ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 7- 61 MDS D522 special version Article number MDS D522 special version 6GT2600-5AF00-0AX0 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 307 Transponder 7.25 MDS D522 special variant 7.25.3 Mounting in metal Flush-mounting Figure 7-69 7.25.4 Flush installation of the MDS D522 special version in metal without clearance Installation instructions The transponder MDS D522 special version is designed to be mounted once. Note the following instructions when mounting the MDS D522 in a workpiece to avoid damaging the transponder: ● Prepare the workpiece according to the following drawing. ● Using the accompanying mounting aid, press the transponder with uniform and evenly distributed pressure into the drilled hole until the transponder locks in place. Make sure that the transponder does not become tilted. SIMATIC RF200 308 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.25 MDS D522 special variant Figure 7-70 Dimension drawing: Workpiece drill hole for mounting the MDS D522 special version SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 309 Transponder 7.25 MDS D522 special variant 7.25.5 Technical specifications Table 7- 62 Technical data of MDS D522 special version 6GT2600-5AF00-0AX0 Product type designation SIMATIC MDS D522 special version Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to EN 60721-3-7 Class 7M31) 500 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 18 (+0.1) × 5.2 mm Weight Approx. 1.2 g Type of mounting Clipping in once (with accompanying tool) 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 310 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.25 MDS D522 special variant 7.25.6 Dimensional drawing Figure 7-71 Dimension drawing MDS D522 special version All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 311 Transponder 7.26 MDS D524 7.26 MDS D524 7.26.1 Characteristics MDS D524 Characteristics Area of application Production and distribution logistics as well as in assembly and production lines, can also be used in a harsh industrial environment without problem 7.26.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data (Page 39)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K Ordering data Table 7- 63 Ordering data for MDS D524 Article number MDS D524 Table 7- 64 6GT2600-5AC00 Ordering data of MDS D524 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF200 312 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.26 MDS D524 7.26.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 7-72 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 7-73 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 313 Transponder 7.26 MDS D524 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 7.26.4 Technical specifications Table 7- 65 Technical specifications for MDS D524 6GT2600-5AC00 Product type designation SIMATIC MDS D524 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ SIMATIC RF200 314 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.26 MDS D524 6GT2600-5AC00 Degree of protection to EN 60529 • IP67 • IPx9K Shock according to EN 60721-3-7 Class 7M31) 1000 m/s2 Vibration according to EN 60721-3-7 Class 7M31) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight 7.26.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • Glued 2) • 1x screw M3 3) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The processing instructions of the adhesive manufacturer must be observed. ) To prevent it loosening during operation, secure the screw with screw-locking varnish. Dimension drawing Figure 7-74 Dimensional drawing of MDS D524 All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 315 Transponder 7.27 MDS D526 7.27 MDS D526 7.27.1 Characteristics MDS D526 7.27.2 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data (Page 39)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 7- 66 Ordering data for MDS D526 Article number MDS D526 Table 7- 67 6GT2600-5AH00 Ordering data for MDS D526 accessories Article number Spacer 6GT2690-0AL00 SIMATIC RF200 316 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.27 MDS D526 7.27.3 Mounting on metal Mounting on metal ≥ 25 mm Figure 7-75 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 7-76 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 317 Transponder 7.27 MDS D526 7.27.4 Technical specifications Table 7- 68 Technical specifications for MDS D526 6GT2600-5AH00 Product type designation SIMATIC MDS D526 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM • OTP • 32 bytes Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +100 ℃ • during storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock according to IEC 68-2-271) 500 m/s2 Vibration according to IEC 68-2-61) Torsion and bending load 200 m/s2 Not permitted Design, dimensions and weight Dimensions (Ø x H) 50 x 3.6 mm SIMATIC RF200 318 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.27 MDS D526 6GT2600-5AH00 7.27.5 Weight 13 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 7-77 Dimensional drawing of MDS D526 All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 319 Transponder 7.28 MDS D528 7.28 MDS D528 7.28.1 Characteristics MDS D528 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting Use in assembly and production lines in the powertrain sector The rugged housing of the MDS D528 means that it can also be used in extreme environmental conditions without problems. 7.28.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data (Page 39)" Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 7- 69 Ordering data for MDS D528 Article number MDS D528 6GT2600-5AK00 SIMATIC RF200 320 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.28 MDS D528 7.28.3 Application example Figure 7-78 7.28.4 Application example Technical specifications Table 7- 70 Technical specifications for MDS D528 6GT2600-5AK00 Product type designation SIMATIC MDS D528 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM • OTP • 32 bytes Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data (Page 39)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 321 Transponder 7.28 MDS D528 6GT2600-5AK00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 to +85 ℃ • outside the read/write field • -40 to +125 ℃ • during storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock according to IEC 68-2-271) 500 m/s2 Vibration according to IEC 68-2-61) 200 m/s2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 20 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF200 322 System Manual, 07/2017, J31069-D0227-U001-A9-7619 Transponder 7.28 MDS D528 7.28.5 Dimension drawing Figure 7-79 Dimensional drawing of MDS D528 All dimensions in mm SIMATIC RF200 System Manual, 07/2017, J31069-D0227-U001-A9-7619 323
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Siemens AG Create Date : 2017:07:05 15:24:11+02:00 Modify Date : 2017:08:17 16:15:58+02:00 Subject : SIMATIC Ident Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2017:08:17 16:15:58+02:00 Creator Tool : Acrobat PDFMaker 17 für Word Document ID : uuid:bbce7b7a-f188-413e-baf5-913b15b647bb Instance ID : uuid:43ff9585-ecf0-4b2e-97d4-8826cb4d5232 Format : application/pdf Title : SIMATIC RF200 Description : SIMATIC Ident Creator : Siemens AG Producer : Adobe PDF Library 15.0 Source Modified : D:20170705132114 Company : Siemens AG Comments : Edition : 0.00347050074367873 System : SIMATIC Ident Print-year : 2010 - 2017 Document-class : System Manual Document-class-mrl : Product-group : RFID systems Order-nr : J31069-D0227-U001-A9-7619 Company-short : Siemens Company-long : Siemens AG Page Layout : OneColumn Page Mode : UseOutlines Page Count : 151EXIF Metadata provided by EXIF.tools