Siemens RF340R01 Inductive Tag Reader User Manual SIMATIC RF300
Siemens AG Inductive Tag Reader SIMATIC RF300
Siemens >
Contents
- 1. User Manual I
- 2. User Manual II
- 3. User Manual III
- 4. User Manual IV
User Manual II
Readers 5.2 SIMATIC RF310R with IQ-Sense interface 5.2 SIMATIC RF310R with IQ-Sense interface 5.2.1 Features RF310R with IQ-Sense Characteristics Design â IQ-Sense interface Field of application Identification tasks on small assembly lines in harsh industrial environments Read/write distance to transponder Max. 35 mm Data transmission rate ďˇ ďˇ âĄ Status display Read: approx. 50 bytes/s Write: approx. 40 bytes/s Note SIMATIC RF310R with IQ-Sense interface is not suitable for combining with ISO tags. 5.2.2 Ordering data of RF310R with IQ-Sense interface RF310R ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ 5.2.3 With IQ-Sense interface IP67 Operating temperature: -25 °C to +70 °C Dimensions: 55 x 75 x 30 (L x W x H, in mm) with integrated antenna Max. limit distance: 35 mm (depending on transponder) 6GT2801-0AA00 Pin assignment of RF310R IQ-Sense interface Table 5- 1 Pin 100 Order number Pin assignment of RF310R with IQ-Sense interface Pin, device end, 4-pin M12 Assignment IQ-Sense Not assigned IQ-Sense SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.2 SIMATIC RF310R with IQ-Sense interface Pin Pin, device end, 4-pin M12 Assignment Not connected 5.2.4 5.2.5 Display elements of the RF310R reader with IQ-Sense interface Color Meaning Green Operating voltage available yellow Transponder present Red Error occurred (see FC35 documentation, Section "Error messages and troubleshooting", Subsection "Error messages, error_MOBY") Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. 5.2.6 Metal-free area The RF310R can be flush-mounted in metal. Please allow for a possible reduction in the field data values. 6,0$7,& 5)5 Figure 5-1 Metal-free area for RF310R To avoid any impact on the field data, the distance a should be ⼠20 mm. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 101 Readers 5.2 SIMATIC RF310R with IQ-Sense interface 5.2.7 Minimum distance between RF310R readers 6,0$7,& 5)5 'E 'D 6,0$7,& 5)5 Da ⼠100 mm Db ⼠100 mm Figure 5-2 5.2.8 Minimum distance between RF310R readers Technical data for RF310R reader with IQ-Sense interface Table 5- 2 102 6,0$7,& 5)5 Technical specifications for RF310R reader with IQ-Sense interface Inductive interface to the transponder Transmission frequency for power/data 13.56 MHz Interface to SIMATIC S7-300 Required master module RFID channels (RF310R) Mixed operation with other profiles IQ-Sense, 2-wire non-polarized 8-IQ-Sense (6ES7 338-7XF00-0AB0) max. 2 per master module, max. 4 Opto-BEROs, 1x SIMATIC RF310R Cable length reader - communication module Max. 50 m (unshielded cable) Read/write distances of reader See Chapter Field data of RF300 transponders (Page 41) Minimum distance between two RF310R readers ⼠100 mm Data transfer rate for read/write device Reading Writing Approx. 50 byte/s Approx. 40 byte/s Passing speed Reading Writing Approx. 0.8 m/s (2 bytes) Approx. 0.8 m/s (2 bytes) Function Read, write, initialize transponder Multi-tag No Power supply via IQ-Sense master module 24 V DC SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.2 SIMATIC RF310R with IQ-Sense interface 5.2.9 Display elements 2-color LED (operating voltage, presence, error) Plug-in connector M12 (4-pin) Enclosure Dimensions (in mm) Color Material 55 x 75 x 30 (without M12 enclosure connector) Anthracite Plastic PA 12 Fixing 4 x M5 screws Ambient temperature during operation during transport and storage -25°C to +70°C -40°C to +85°C Degree of protection to EN 60529 IP67 Shock to EN 60721-3-7 Class 7 M2 Vibration to EN 60721-3-7 Class 7 M2 50 g 20 g Weight Approx. 150 g MTBF (Mean Time Between Failures) in years 153.5 Approvals Radio to R&TTE guidelines EN 300 330, EN 301 489, CE, FCC, UL/CSA Current consumption Typ. 40 mA FCC information Siemens SIMATIC RF300 with IQ-Sense interface FCC ID: NXW-RF310R-IQ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 103 Readers 5.3 SIMATIC RF310R with RS422 interface Dimension drawing 5.2.10 6,0$7,& 5)5 Figure 5-3 Dimension drawing for RF310R Dimensions in mm 5.3 SIMATIC RF310R with RS422 interface 5.3.1 Features RF310R with RS422 Characteristics Design â RS422 interface ⥠Status display 104 Field of application Identification tasks on small assembly lines in harsh industrial environments Read/write distance to transponder Max. 90 mm Data transmission rate RF300 tags ISO tags Read write Approx. 8000 byte/s Approx. 8000 byte/s Approx. 600 byte/s Approx. 400 byte/s SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.3 SIMATIC RF310R with RS422 interface 5.3.2 Ordering data for RF310R with RS422 interface RF310R 5.3.3 Order number With RS422 interface (3964R) IP 67 Operating temperature: -25 °C to +70 °C Dimensions: 55 x 75 x 30 (L x W x H, in mm) with integrated antenna Max. limit distance: 35 mm (depending on transponder) ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ Pin assignment of RF310R RS422 interface Pin Pin Device end 8-pin M12 5.3.4 Assignment + 24 V - Transmit 0V + Transmit + Receive - Receive Free Earth (shield) Display elements of the RF310R reader with RS422 interface Color Green Meaning Flashing Operating voltage present, reader not initialized or antenna switched off Permanentl y on Operating voltage present, reader initialized and antenna switched on Yellow1) Transponder present Flashing red Error has occurred, the type of flashing corresponds to the error code in the table in Section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1", see FC45 / FB45 documentation, Section "Input parameters") is set. 1) 5.3.5 6GT2801-1AB10 Only in the "with presence" mode. Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 105 Readers 5.3 SIMATIC RF310R with RS422 interface 5.3.6 Metal-free area The RF310R can be flush-mounted in metal. Please allow for a possible reduction in the field data values. 6,0$7,& 5)5 Figure 5-4 Metal-free area for RF310R To avoid any impact on the field data, the distance a should be ⼠20 mm. 5.3.7 Minimum distance between RF310R readers 6,0$7,& 5)5 'E 'D 6,0$7,& 5)5 Da ⼠100 mm Db ⼠200 mm Figure 5-5 106 6,0$7,& 5)5 Minimum distance between RF310R readers SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.3 SIMATIC RF310R with RS422 interface 5.3.8 Technical specifications of the RF310R reader with RS422 interface Table 5- 3 Technical specifications of the RF310R reader with RS422 interface Inductive interface to the transponder Transmission frequency for power/data 13.56 MHz Antenna integrated Interface to the communication module RS422 (3964R protocol) Baud rate 19200 baud, 57600 baud, 115200 baud Cable length reader - communication module Data cable length max. 1000 m (shielded cable) Read/write distances of reader See Chapter Field data of RF300 transponders (Page 41) Minimum distance between two RF310R readers ⼠100 mm or ⼠200 mm Maximum data transmission range, reader transponder (tag) RF300 tags ISO tags Read write Approx. 8000 bytes/s Approx. 8000 bytes/s Approx. 600 bytes/s Approx. 400 bytes/s Functions Initialize/read/write transponder Scan status and diagnostics information Switch antenna on/off Repeat command Scan transponder serial numbers Power supply 24 V DC Display elements 2-color LED (operating voltage, presence, error) Plug-in connector M12 (8-pin) Enclosure Dimensions (in mm) Color Material 55 x 75 x 30 (without M12 plug connector) Anthracite Plastic PA 12 Fixing 4 x M5 screws Ambient temperature during operation during transport and storage -25 °C to +70 °C -40 °C to +85 °C Degree of protection to EN 60529 IP67 Shock to EN 60721-3-7 Class 7 M2 Vibration to EN 60721-3-7 Class 7 50 g 20g Weight Approx. 170 g MTBF (Mean Time Between Failures) in years 169.9 Approvals Radio to R&TTE guidelines EN 300 330, EN 301 489, CE, FCC, UL/CSA Current consumption Typ. 50 mA SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 107 Readers 5.3 SIMATIC RF310R with RS422 interface 5.3.9 FCC information Siemens SIMATIC RF310R with RS422 interface FCC ID: NXW-RF310R This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Dimension drawing 5.3.10 Figure 5-6 6,0$7,& 5)5 Dimension drawing for RF310R Dimensions in mm 108 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.4 SIMATIC RF340R 5.4 SIMATIC RF340R 5.4.1 Features RF340R Characteristics Design â RS422 interface Field of application Identification tasks on assembly lines in harsh industrial environments Read/write distance to transponder Max. 65 mm Data transmission rate RF300 tags Read ďˇ âĄ Status display Write 5.4.2 ďˇ Ordering data for RF340R RF340R ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ 5.4.3 ISO tags approx. 8000 byte/s approx. 8000 byte/s Order number With RS422 interface (3964R) IP 67 Operating temperature -25 °C ⌠+70 °C Dimensions 75 x 91 x 41 (L x W x H in mm) with integrated antenna Max. limit distance: 65 mm (depending on transponder) 6GT2801-2AB10 Pin assignment of RF340R RS422 interface Pin Pin Device end 8-pin M12 Assignment + 24 V - Transmit 0V + Transmit + Receive - Receive Free SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 109 Readers 5.4 SIMATIC RF340R Pin Pin Device end 8-pin M12 5.4.4 Earth (shield) Display elements of the RF340R reader Color Meaning Green Flashing Operating voltage present, reader not initialized or antenna switched off Permanentl y on Operating voltage present, reader initialized and antenna switched on Yellow1) Transponder present Flashing red Error has occurred, the type of flashing corresponds to the error code in the table in Section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1", see FC45 / FB45 documentation, Section "Input parameters") is set. 1) 5.4.5 Assignment Only in the "with presence" mode. Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. 5.4.6 Metal-free area The RF340R can be flush-mounted in metal. Please allow for a possible reduction in the field data values. 6,0$7,& 5)5 Figure 5-7 Metal-free area for RF340R To avoid any impact on the field data, the distance a should be ⼠20 mm. 110 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.4 SIMATIC RF340R 5.4.7 Minimum distance between RF340R readers 5)5 'E 'D 5)5 Da ⼠100 mm Db ⼠250 mm Figure 5-8 5.4.8 5)5 Minimum distance between RF340R readers Technical data of the RF340R reader Table 5- 4 Technical specifications of the RF340R reader Inductive interface to the transponder Transmission frequency for power/data 13.56 MHz Antenna integrated Interface to the communication module RS422 (3964R protocol) Baud rate 19200 baud, 57600 baud, 115200 baud Cable length reader - communication module Data cable length max. 1000 m (shielded cable) Read/write distances of reader See Chapter Field data of RF300 transponders (Page 41) Minimum distance between two RF340R readers ⼠100 mm or ⼠250 mm Maximum data transfer rate reader - transponder (tag) Reading Writing RF300 tags Functions Initialize/read/write transponder Scan status and diagnostics information Switch antenna on/off Repeat command Scan transponder serial numbers Power supply 24 V DC SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 ISO tags Approx. 8000 byte/s Approx. 8000 byte/s 111 Readers 5.4 SIMATIC RF340R 5.4.9 Display elements 2-color LED (operating voltage, presence, error) Plug connector M12 (8-pin) Enclosure Dimensions (in mm) Color Material 75 x 75 x 40 (without M12 device connector) Anthracite Plastic PA 12 Fixing 2 x M5 screws Ambient temperature during operation during transport and storage -25 °C to +70 °C -40 °C to +85 °C Degree of protection to EN 60529 IP67 Shock to EN 60721-3-7 Class 7 M2 Vibration to EN 60721-3-7 Class 7 M2 50 g 20 g Weight Approx. 250 g MTBF (Mean Time Between Failures) in years 140 Approvals Radio to R&TTE guidelines EN 300 330, EN 301 489, CE, FCC, UL/CSA Current consumption Typ. 100 mA FCC information Siemens SIMATIC RF340R (MLFB 6GT2801-2AA10) FCC ID: NXW-RF340R Siemens SIMATIC RF340R (MLFB 6GT2801-2AB10) FCC ID: NXW-RF340R01 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 112 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R Dimension drawing 5.4.10 Figure 5-9 6,0$7,& 5)5 Dimension drawing for RF340R Dimensions in mm 5.5 SIMATIC RF350R 5.5.1 Features RF350R Characteristics Design â Antenna connection ⥠RS422 interface ⢠Status display Field of application Identification tasks in assembly lines in harsh industrial environments; for external antennas (ANT 1, ANT 18, ANT 30) Read/write distance to transponder Max. 60 mm Data transmission rate RF300 tags SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 ISO tags 113 Readers 5.5 SIMATIC RF350R RF350R Characteristics Read ďˇ Write 5.5.2 ďˇ Read: approx. 8000 byte/s Write: approx. 8000 byte/s Ordering data for RF350R RF350R ďˇ ďˇ ďˇ ďˇ ďˇ 5.5.3 Order number With RS422 interface (3964R) IP65 Operating temperature: -25 °C ⌠+70 °C Dimensions: 75 x 96 x 41 (L x W x H, in mm) For pluggable antennas ANT 1, ANT 12, ANT 18, ANT 30 Pin assignment of RF350R RS422 interface Pin Pin Device end 8-pin M12 114 6GT2801-4AB10 Assignment + 24 V - Transmit 0V + Transmit + Receive - Receive Free Earth (shield) SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R 5.5.4 Display elements of the RF350R reader Color Green Flashing Operating voltage present, reader not initialized or antenna switched off Permanently on Operating voltage present, reader initialized and antenna switched on Yellow1) Transponder present Flashing red Error has occurred, the type of flashing corresponds to the error code in the table in Section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1", see FC45 / FB45 documentation, Section "Input parameters") is set. 1) 5.5.5 Meaning Only in the "with presence" mode. Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. 5.5.6 Metal-free area The RF350R reader does not have an internal antenna. Operation is not affected by mounting on metal or flush-mounting in metal. For information about the metal-free area required by the external antennas, refer to the corresponding section of the chapter Antennas (Page 118). 5.5.7 Technical data of the RF350R reader Table 5- 5 Technical specifications of the RF350R reader Inductive interface to the transponder Transmission frequency for power/data Antenna 13.56 MHz External, antennas ANT 1, ANT 12, ANT 18 or ANT 30 Interface to the communication module RS422 (3964R protocol) Baud rate 19200 baud, 57600 baud, 115200 baud Cable length reader - communication module Data cable length max. 1000 m (shielded cable) Read/write distances of reader See Chapter Field data of RF300 transponders (Page 41) Minimum distance between two antennas See Chapter Minimum clearances (Page 47) Maximum data transfer rate reader - transponder (tag) Reading Writing RF300 tags ISO tags Approx. 8000 byte/s Approx. 8000 byte/s @ Werte SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 115 Readers 5.5 SIMATIC RF350R Functions 5.5.8 Initialize/read/write transponder Scan status and diagnostics information Switch antenna on/off Repeat command Scan transponder serial numbers Power supply 24 V DC Display elements 2-color LED (operating voltage, presence, error) Plug connector M12 (8-pin); M8 (4-pin) for antenna Enclosure ďˇ Dimensions (in mm) ďˇ Color ďˇ Material ďˇ ďˇ ďˇ Fixing 2 x M5 screws Ambient temperature ďˇ During operation ďˇ Transport and storage ďˇ ďˇ Degree of protection to EN 60529 IP65 Shock to EN 60721-3-7 Class 7 M2 Vibration to EN 60721-3-7 Class 7 M2 50 g 20 g Weight 250 g MTBF (Mean Time Between Failures) in years 140 Approvals Radio to R&TTE guidelines EN 300 330, EN 301 489, CE, FCC, UL/CSA Current consumption Typ. 100 mA 75 x 75 x 40 (without M12 device connector) Anthracite Plastic PA 12 -25 °C to +70 °C -40 °C to +85 °C FCC information Siemens SIMATIC RF350R (MLFB 6GT2801-2AA10) FCC ID: NXW-RF350R Siemens SIMATIC RF350R (MLFB 6GT2801-2AB10) FCC ID: NXW-RF350R01 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 116 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R Dimension drawing 5.5.9 6,0$7,& 5)5 Figure 5-10 RF350R dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 117 Readers 5.5 SIMATIC RF350R 5.5.10 Antennas 5.5.10.1 Features For the RF350R reader, you can use the following pluggable antennas: Antenna Product photo ANT 1 Limit distance Sg in mm 1) Dimensions (L x B x H) in mm Suitable for dynamic operation to 60 75 x 75 x 20 Yes ANT 12 M12 x 1.0 x 40 (â x thread x L) @ <--> Schreibweise wie bei den anderen Antennen? Klammer? ANT 18 to 13 Ă M18 x 50 No ANT 30 to 22 Ă M30 x 58 No 1) Depending on the transponder used ANT 1 The ANT 1 is an antenna in the mid performance range and can be used to the customer's advantage in production and assembly lines due to its manageable housing shape. The antenna dimensions make it possible to read/write large quantities of data dynamically from/to the tag during operation. The antenna cable can be connected at the reader end. 118 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R ANT 12 The ANT 12 is primarily envisaged for tool identification applications. The very small size of the antenna means that highly exact positioning is possible using the plastic nuts included in the scope of delivery. The antenna cable can be connected at the SLG end. Communication with the data storage unit is only possible with the MDS D421 in static mode. ANT 18 The ANT 18 is designed for use in small assembly lines. Due to its small, compact construction, the antenna can be easily positioned for any application using two plastic nuts (included in the package). The antenna cable can be connected at the reader end. Data communication is only possible with the RF320T and RF340T tags in static mode. ANT 30 The ANT 30 is designed for use in small assembly lines. In comparison to ANT 18, the maximum write/read distance is approximately 60 % larger. Due to its compact construction, the antenna can be easily positioned for any application using two plastic nuts (included in the package). The antenna cable can be connected at the reader end. With the RF320T, RF340T and RF350T tags, communication with the data storage unit is only possible in static mode. 5.5.10.2 5.5.10.3 Ordering data for antennas Antenna Order number ANT 1 6GT2398-1CB00 ANT 12 6GT2 398-1CC00 ANT 18 6GT2398-1CA00 ANT 30 6GT2398-1CD00 Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. 5.5.10.4 Metal-free area The antennas ANT 1, ANT 12, ANT 18 and ANT 30 can be flush-mounted on metal. Please allow for a possible reduction in the field data values. During installation, maintain the minimum distances (a and b) on/flush with the metal. NOTICE Reduction of range if the metal-free space is not maintained At values lower than a and b, the field data changes significantly, resulting in a reduction in the limit distance and operating distance. Therefore, during installation, maintain the minimum distances (a and b) on/flush with the metal. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 119 Readers 5.5 SIMATIC RF350R Metal-free space for flush-mounted installation of ANT 1 0HWDO a= 40 mm Figure 5-11 Metal-free area for ANT 1 Flush-mounting of ANT 12 02%<( $17 Figure 5-12 Metal-free area for ANT 12 The ANT 12 can be flush-mounted in metal. Metal-free space for flush-mounted installation of ANT 18 $17 a= 10 mm b= 10 mm Figure 5-13 120 Metal-free area for ANT 18 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R Metal-free space for flush-mounted installation of ANT 30 $17 a= 20 mm b= 20 mm Figure 5-14 5.5.10.5 Metal-free area for ANT 30 Minimum distance between antennas Minimum distance for ANT 1 'D $17 $17 'E $17 Da ⼠100 mm Db ⼠250 mm Figure 5-15 Minimum distance for ANT 1 The reader electronics can be mounted directly alongside each other. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 121 Readers 5.5 SIMATIC RF350R Minimum distance for ANT 12 'D 'E Da > 80 mm Db > 80 mm Figure 5-16 Minimum distance for ANT 12 Minimum distance for ANT 18 'D 'E Da ⼠100 mm Db ⼠200 mm Figure 5-17 122 Minimum distance for ANT 18 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.5 SIMATIC RF350R Minimum distance for ANT 30 'D 'E Da ⼠100 mm Db ⼠250 mm Figure 5-18 5.5.10.6 Minimum distance for ANT 30 Technical data for antennas Table 5- 6 Technical data for antennas ANT 1, ANT 12, ANT 18 and ANT 30 ANT 1 ANT 12 ANT 18 ANT 30 100 mm 5 mm 15 mm 22 mm 75 x 75 x 20 (L x W x H) M18 x 1.0 x 55 (â x thread x L) M18 x 1.0 x 55 (Ă x thread x L) M30 x 1.5 x 58 (Ă x thread x L) 2 plastic nuts M18 x 1.0 2 plastic nuts M30 x 1.5 Read/write distance antenna to transponder (Sg) max Enclosure dimensions in mm Color Anthracite Pale turquoise Material Plastic PA 12 Plastic Crastin Plug connection 4-pin (pins on antenna side) Antenna cable lengths 3m Degree of protection to EN 60529 IP67 Shock-resistant acc. to EN 60721-3-7, Class 7M2 IP67 (front) 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7M2 20 g ( 3 to 500 Hz) 1) Attachment of the antenna 2 x M5 screws SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 2 plastic nuts M12 x 1.0 123 Readers 5.5 SIMATIC RF350R ANT 1 Ambient temperature ďˇ During operation ďˇ Transport and storage -25 °C to +70 °C MTBF (at +40 °C) 2.5 x 105 hours 5.5.10.7 ANT 18 ANT 30 45 g 120 g 150 g -40 °C to +85 °C Approx. weight 1) ANT 12 80 g Warning: The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawings for antennas All dimensions in mm 0LQLPXPEHQGLQJ UDGLXV 20 mm &DEOHOHQJWKP $17FDQEHFRQQHFWHG DWUHDGHUHQG Dimension drawing for ANT 1 &DEOHOHQJWKP 0LQLPXPEHQGLQJ UDGLXV PP $QWHQQD HQG 0 )LQHWKUHDGSLWFK Figure 5-19 6LGHYLHZRI DQWHQQDKHDG $QWHQQD KHDG $17FDQEHFRQQHFWHG DWUHDGHUHQG Figure 5-20 Dimension drawing for ANT 12 0LQLPXPEHQGLQJ UDGLXV PP $17 6LGHYLHZRI DQWHQQDKHDG $QWHQQD KHDG $17FDQEHFRQQHFWHG DWUHDGHUHQG 124 $QWHQQD HQG 0 )LQHWKUHDG SLWFK &DEOHOHQJWKP Figure 5-21 $17 Dimension drawing for ANT 18 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.6 SIMATIC RF380R $QWHQQD HQG 0 )LQHWKUHDG SLWFK &DEOHOHQJWKP 0LQLPXPEHQGLQJ UDGLXV PP $QWHQQD KHDG 6LGHYLHZRI DQWHQQDKHDG $17FDQEHFRQQHFWHG DWUHDGHUHQG Figure 5-22 $17 Dimension drawing for ANT 30 5.6 SIMATIC RF380R 5.6.1 Features RF380R Characteristics Design â RS232 or RS422 interface Field of application Identification tasks on assembly lines in harsh industrial environments Read/write distance to transponder Max. 210 mm Data transmission rate RF300 tags ISO tags Read write Approx. 8000 byte/s Approx. 8000 byte/s Approx. 600 byte/s Approx. 400 byte/s ⥠Status display 5.6.2 RF380R ordering data RF380R ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ With RS422 interface (3964R) IP67 Operating temperature: -25 °C ⌠+70 °C Dimensions: 160 x 96 x 40 (L x W x H, in mm) with integrated antenna max. limit distance 150 mm (dependent on transponder) SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Order number 6GT2801-3AB10 125 Readers 5.6 SIMATIC RF380R 5.6.3 Pin assignment of RF380R RS232/RS422 interface You can connect the RF380R reader to a higher-level system via the internal RS422 interface or via the RS232 interface. After connection, the interface module automatically detects which interface has been used. Note correct assignment of the pins here: Pin Pin Device end 8-pin M12 5.6.4 RS232 RS422 + 24 V + 24 V RXD - Transmit 0V 0V TXD + Transmit NC + Receive NC - Receive not used not used Earth (shield) Earth (shield) Display elements of the RF380R reader Color Green Meaning Flashing Operating voltage present, reader not initialized or antenna switched off Permanently on Operating voltage present, reader initialized and antenna switched on Yellow1) Transponder present Flashing red Error has occurred, the type of flashing corresponds to the error code in the table in Section "Error codes". The optical error display is only reset if the corresponding reset parameter ("option_1", see FC45 / FB45 documentation, Section "Input parameters") is set. 1) 5.6.5 Assignment Only in the "with presence" mode. Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. 126 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.6 SIMATIC RF380R 5.6.6 Metal-free area The RF380R can be flush-mounted in metal. Please allow for a possible reduction in the field data values. 6,0$7,& 5)5 Figure 5-23 Metal-free area for RF380R To avoid any impact on the field data, the distance a should be ⼠20 mm. 5.6.7 Minimum distance between RF380R readers 'E 'D Da ⼠400 mm Db ⼠400 mm Figure 5-24 Minimum distance between RF380R readers SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 127 Readers 5.6 SIMATIC RF380R 5.6.8 Technical specifications of the RF380R reader Table 5- 7 128 Technical specifications of the RF380R reader Inductive interface to the transponder Transmission frequency for power/data 13.56 MHz Antenna integrated Interface to the communication module RS232 or RS422 (3964R protocol) Baud rate 19200 baud, 57600 baud, 115200 baud Cable length reader - communication module RS422 data cable length: max. 1000 m RS232 data cable length: Max. 30 m Read/write distances of reader See Chapter Field data of RF300 transponders (Page 41) Minimum distance between two RF380R readers ⼠500 mm Maximum data transmission range reader - transponder (tag) RF300 tags ISO tags Read write Approx. 8000 byte/s Approx. 8000 byte/s Approx. 600 byte/s Approx. 400 byte/s Functions Initialize/read/write transponder Scan status and diagnostics information Switch antenna on/off Repeat command Scan transponder serial numbers Power supply 24 V DC Display elements 2-color LED (operating voltage, presence, error) Plug connector M12 (8-pin) Enclosure Dimensions (in mm) Color Material 160 x 80 x 40 (without M12 plug connector) Anthracite Plastic PA 12 Fixing 4 x M5 screws Ambient temperature ďˇ During operation ďˇ Transport and storage ďˇ ďˇ Degree of protection to EN 60529 IP67 Shock to EN 60 721-3-7 Class 7 M2 Vibration to EN 60 721-3-7 Class 7 M2 50 g 20 g -25 °C to +70 °C -40 °C to +85 °C Weight Approx. 600 g MTBF (Mean Time Between Failures) in years 109 years Approvals Radio to R&TTE guidelines EN 300 330, EN 301 489, CE, FCC, UL/CSA Current consumption Typ. 160 mA SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.6 SIMATIC RF380R 5.6.9 FCC information Siemens SIMATIC RF380R (MLFB 6GT2801-3AA10) FCC ID: NXW-RF380R Siemens SIMATIC RF380R (MLFB 6GT2801-3AB10) FCC ID: NXW-RF380R01 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 5.6.10 Use of the reader in hazardous areas The TĂV SĂD Automotive GmbH as approved test center as well as the TĂV SĂD Product Service GmbH as certification center, identification number 0123, as per Article 9 of the Directive of the European Council of 23 March 1994 (94/9/EC), has confirmed the compliance with the essential health and safety requirements relating to the design and construction of equipment and protective systems intended for use in hazardous areas as per Annex II of the Directive. The essential health and safety requirements are satisfied in accordance with the following standards: Document Title EN 60079-0: 2006 Electrical equipment for hazardous gas atmospheres Part 0: General requirements EN 60079-15: 2005 Electrical equipment for hazardous gas atmospheres Part 15: Design, testing and identification of electrical equipment with type of protection "n" DIN VDE 0848-5: 2001 (in parts) Safety in electrical, magnetic and electromagnetic fields Part 5: Explosion protection ZLS SK 107.1 Central office of the states for safety; test components Identification The identification of the electrical equipment as an enclosed unit is: II 3G Ex nC IIB T5 -25 °C to +70 °C Um = 30 V DC The equipment is assigned the following references: XXXYYYZZZ [= serial number, is assigned during production] TPS 09 ATEX 1 459 X [= certificate number] SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 129 Readers 5.6 SIMATIC RF380R "No use of the equipment in the vicinity of processes generating high charges" "Do not disconnect plug on load" 5.6.11 Use of the reader in hazardous areas for gases Temperature class delineation for gases The temperature class of the reader for hazardous areas depends on the ambient temperature range: Ambient temperature range Temperature class -25 °C to +70 °C T5 WARNING Ignitions of gas-air mixtures When using the RF380R reader, check to ensure that the temperature class is observed in respect of the requirements of the area of application Non-compliance with the permitted temperature ranges while using the reader can lead to ignitions of gas-air mixtures. 5.6.12 Installation and operating conditions for the hazardous area a) The connector on the RF380R must be grounded via its supply line. b) Use of the equipment in the vicinity of processes generating high charges is not allowed. c) The plug of the RF380R must not be disconnected in a hazardous atmosphere or under load. d) The supply line for the RF380R is not part of this certificate. The supply line must exhibit a sufficient temperature resistance. e) The equipment must be mechanically protected when installed. 130 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Readers 5.6 SIMATIC RF380R Dimension drawing 5.6.13  6,0$7,& 5)5 Figure 5-25 Dimension drawing RF380R Dimensions in mm SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 131 RF300 transponder 6.1 Overview of RF300 tags Characteristics of the RF300 tags The RF300 tags (RF3xxT) stand out particularly for their extremely fast data exchange with the RF300 readers (RF3xxR). With the exception of the RF320T transponder, all of the RF300 tags have 8 to 64 KB of FRAM memory, which has an almost unlimited capacity for read/write actions. RF300 tags The following RF300 tags can be used at any time with RF300: â RF320T â RF340T â RF350T â RF360T â RF370T â RF380T SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 133 RF300 transponder 6.2 Memory configuration of the RF300 tags 6.2 Memory configuration of the RF300 tags ))) 8,' UHDGRQO\ E\WHV 5)7 5)7 5)7 5)7 5)7 5)7 ))) )) 8VHUDUHD UHDGZULWH ((3520 E\WHV )) 273 QRWZLWK ,46HQVH )) ))& )) )) )) 0D[b EORFNVRI E\WHVHDFK )()& 5)7 .% 5)7 .% 5)7 .% 5)7 .% 5)7 .% 5)7 .% ))& 8VHUDUHD UHDGZULWH )5$0 ))& 1) Physically identical memory When the OTP area is used, the corresponding user area (FF00-FF13) can no longer be modified (read only). Figure 6-1 134 Memory configuration of the RF300 tags SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.2 Memory configuration of the RF300 tags EEPROM area The memory configuration of an RF300 tag always comprises an EEPROM memory that has 20 bytes for user data (read/write) and a 4 byte unique serial number (UID, read only). For reasons of standardization, the UID is transferred as an 8 byte value through a read command to address FFF0 with a length of 8. The unused 4 high bytes are filled with zeros. Note The EEPROM user memory (address FF00-FF13, or FF80-FF90) requires significantly more time for writing (approx. 11 ms/byte) than the high-speed FRAM memory. For time-critical applications with a write function, it is therefore recommended that FRAM tags are used (e.g. RF340T, RF350T, RF360T, RF370T, RF380T). FRAM area Depending on the tag type, high-speed FRAM memory is available. (8 KB, 32 KB, 64 KB). This area does not exist for the RF320T. In the case of RF3xxT tags with FRAM memory, the data carrier initialization command (INIT) is only effective on this memory area but not on the EEPROM area (FF00-FF13). OTP area The EEPROM memory area (address FF00-FF13) can also be used as a so-called "OTP" memory (One Time Programmable). The 5 block addresses FF80, FF84, FF88, FF8C and FF90 are used for this purpose. A write command to this block address with a valid length (4, 8, 12, 16, 20 depending on the block address) protects the written data from subsequent overwriting. Note The OTP area cannot be used for the IQ-Sense reader variant. Note Seamless use of the OTP area When the OTP area is used, it must be ensured that the blocks are used starting from Block 0 consecutively. Examples: 3 blocks (with write command), Block 0, 1, 2 (FF80, length = 12): valid 2 blocks (consecutive), Block 0 (FF80, length =4), Block 1 (FF84, length = 4): valid 2 blocks (consecutive), Block 0 (FF80, length =4), Block 2 (FF88, length = 4): Invalid 1 Block, Block 4 (FF90, length = 4): Invalid SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 135 RF300 transponder 6.3 SIMATIC RF320T NOTICE Use of the OTP area is not reversible. If you use the OPT area, you cannot undo it, because the OPT area can only be written to once. 6.3 SIMATIC RF320T 6.3.1 Features RF320T Characteristics Field of application Identification tasks on small assembly lines in harsh industrial environments Memory Read-only area (4 bytes UID) Read/write range See Section Field data of RF300 transponders (Page 41) Mounting on metal Not possible: Recommended distance from metal ⼠20 mm User data area (20 bytes) 6.3.2 Ordering data Table 6- 1 Ordering data RF320T RF320T ďˇ ďˇ ďˇ ďˇ ďˇ 6.3.3 Order number Button Memory size: 20 byte EEPROM IP67 Operating temperature: -25 °C to +85 °C Dimensions: Ă = 27 mm x 4 mm 6GT2800-1CA00 Mounting on metal Mounting of RF320T on metal Direct mounting of the RF320T on metal is not allowed. 136 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.3 SIMATIC RF320T The following figures show the minimum distance between the RF320T and metal: 'DWDPHPRU\ 0HWDO 1RQPHWDO > 20 mm Figure 6-2 Mounting of an RF320T on metal with spacer Flush-mounting of RF320T in metal 'DWDPHPRU\ 0HWDO 1RQPHWDO > 20 mm > 20 mm Figure 6-3 Flush-mounting of RF320T in metal with spacer At lower values, the field data change significantly, resulting in a reduced range. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 137 RF300 transponder 6.3 SIMATIC RF320T 6.3.4 Technical data Table 6- 2 Technical data for RF320T Memory size 20 bytes EEPROM (r/w), 4 bytes UID (ro) Memory organization Byte-oriented access, write protection possible in 4-byte blocks MTBF (Mean Time Between Failures) in years 1800 Read cycles Unlimited Write cycles, min. 50 000 at ⤠40 °C, typical > 100 000 Data retention time > 10 years (at < +40 °C) Read/write distance Dependent on the reader used [see Chapter Field data of RF300 transponders (Page 41) ] Energy source Inductive power transmission Shock/vibration-resistant to EN 60721-3-7, Class 7 M3 100 g/20 g Torsion and bending load Not permissible Fixing Adhesive/M3 screws Recommended spacing from metal > 20 mm Degree of protection to EN 60529 ďˇ Housing ďˇ Dimensions ďˇ Color/material Button ďˇ Ă 27 mm x 4 mm ďˇ Black/epoxy resin Ambient temperature ďˇ Operation ďˇ Transport and storage ďˇ ďˇ Weight Approx. 5 g IP67/IPX9K -25 to +85 °C -40 to +125 °C Note All the technical data listed are typical data and are applicable for an ambient temperature between 0 and +50 °C and a metal-free environment. 138 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.4 SIMATIC RF340T 6.3.5 Dimension drawing    Figure 6-4 RF320T dimension drawing Dimensions in mm 6.4 SIMATIC RF340T 6.4.1 Features RF340T Characteristics Field of application Identification tasks on small assembly lines in harsh industrial environments Memory Read-only area (4 bytes UID) Read/write memory (8 KB) OTP 1) memory (20 bytes) 1) Read/write range See Section Field data of RF300 transponders (Page 41) Mounting on metal Direct mounting on metal is possible. OTP: (One Time Programmable) 6.4.2 Ordering data Table 6- 3 Ordering data RF340T RF340T ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 8 KB FRAM Operating temperature: -25 °C to +85 °C Dimensions: 48 x 25 x 15 (L x W x H, in mm) SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Order number 6GT2800-4BB00 139 RF300 transponder 6.4 SIMATIC RF340T 6.4.3 Mounting on metal Direct mounting of the RF340T on metal is permitted. Mounting of RF340T on metal 0HWDO Figure 6-5 Mounting of RF340T on metal Flush-mounting of RF340T in metal: 0HWDO Figure 6-6 Flush-mounting of RF340T in metal The standard value for a is ⼠20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. 140 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.4 SIMATIC RF340T 6.4.4 Technical specifications Table 6- 4 Technical specifications for RF340T Memory size 8 KB Memory organization Blocks of 8 bits/byte-by-byte Memory configuration ďˇ Serial number (UID) ďˇ Application memory ďˇ OPT memory ďˇ ďˇ ďˇ Storage technology FRAM / EEPROM MTBF (Mean Time Between Failures) in years 1200 Write cycles, at +40 °C Virtually unlimited (>1010) Read cycles Virtually unlimited (>1010) Data transmission time ďˇ Read ďˇ Write With RS422 reader: With IQ-Sense reader: Approx. 0.13 ms/byte approx. 0.13 ms/byte Approx. 20 ms/byte approx. 25 ms/byte Data retention > 10 years Read/write distance Dependent on the reader used [see Chapter Field data of RF300 transponders (Page 41)] 4 bytes (fixed code) 8189 bytes r/w 20-byte OTP 1) memory Multitag capability max. 4 transponders Recommended spacing from metal can be directly mounted on metal Power supply Inductive, without battery Degree of protection to EN 60529 Shock to EN 60721-3-7 Vibration to EN 60721-3-7 Torsion and bending load IP68/IPX9K 50 g 20 g Not permitted permanently Enclosure dimensions Color Material Fixing 48 x 25 x 15 mm (L x W x H) Anthracite PA12 2 screws (M3) Ambient temperature ďˇ Operation ďˇ Storage and transport -25°C to +85°C -40°C to +85°C Weight Approx. 25 g 1) OTP: One Time Programmable SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 141 RF300 transponder 6.5 SIMATIC RF350T 6.4.5 Dimension drawing 6,(0(16 6,0$7,& 5)7  Figure 6-7 RF340T dimension drawing Dimensions in mm 6.5 SIMATIC RF350T 6.5.1 Features RF350T Characteristics Field of application Memory Identification tasks on small assembly lines in harsh industrial environments Read-only area (4 bytes UID) Read/write memory (32 KB) OTP 1) memory (20 bytes) 1) Read/write range See Section Field data of RF300 transponders (Page 41) Mounting on metal Direct mounting on metal is possible. OTP: One Time Programmable 142 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.5 SIMATIC RF350T 6.5.2 Ordering data Table 6- 5 Ordering data RF350T RF350T ďˇ ďˇ ďˇ ďˇ 6.5.3 Order number IP68 Memory size: 32 KB FRAM (read/write) and 4 byte EEPROM (read only) Operating temperature: -25 °C ⌠+85 °C Dimensions: 50 x 50 x 20 (L x W x H, in mm) 6GT2800-5BD00 Mounting on metal Direct mounting of the RF350T on metal is permitted. Mounting of RF350T on metal Figure 6-8 Mounting of RF350T on metal SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 143 RF300 transponder 6.5 SIMATIC RF350T Flush-mounting of RF350T in metal: Figure 6-9 RF350T flush-mounted in metal The standard value for a is ⼠20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. 6.5.4 Technical data Table 6- 6 144 Technical specifications for RF350T Memory size 32 KB Memory organization Blocks of 8 bits/byte-by-byte Memory configuration ďˇ Serial number (UID) ďˇ Application memory ďˇ OTP 1) memory ďˇ ďˇ ďˇ Storage technology FRAM / EEPROM MTBF (Mean Time Between Failures) in years 1200 Write cycles, at +40 °C Virtually unlimited (>1010) Read cycles Virtually unlimited (>1010) Data transmission time ďˇ Read ďˇ Write With RS422 reader: With IQ-Sense reader: Approx. 0.13 ms/byte approx. 0.13 ms/byte Approx. 20 ms/byte approx. 25 ms/byte Data retention > 10 years 4 bytes (fixed code) 32765 bytes r/w 20 bytes SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.5 SIMATIC RF350T Read/write distance Dependent on the reader used [see Chapter Field data of RF300 transponders (Page 41)] Multitag capability max. 4 transponders Recommended spacing from metal can be directly mounted on metal Power supply Inductive, without battery Degree of protection to EN 60529 Shock to EN 60721-3-7 Vibration to EN 60721-3-7 Torsion and bending load IP68 50 g 20 g Not permitted permanently Enclosure dimensions Color Material Fixing 50 x 50 x 20 mm (L x W x H) Anthracite PA12 2 screws M4 Ambient temperature ďˇ Operation ďˇ Transport and storage -25 °C to +85 °C -40 °C to +85 °C Weight Approx. 25 g 1) OTP: One Time Programmable SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 145 RF300 transponder 6.5 SIMATIC RF350T 6.5.5 Dimension drawing )L[LQJIUDPH 7UDQVSRQGHU ,QVWDOODWLRQGLDJUDP 7KHWUDQVSRQGHUFDQEHPRXQWHGDVVKRZQZLWK WKHIL[LQJIUDPH Figure 6-10 RF350T dimension drawing Dimensions in mm 146 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.6 SIMATIC RF360T 6.6 SIMATIC RF360T 6.6.1 Features RF360T Characteristics Field of application Identification tasks on small assembly lines in harsh industrial environments Memory Read-only area (4 bytes UID) Read/write memory (8 KB) OTP 1) memory (20 bytes) 1) Read/write range Refer to SectionField data of RF300 transponders (Page 41) Mounting on metal Not possible; recommended distance from metal ⼠20 mm OTP. One Time Programmable 6.6.2 Ordering data Table 6- 7 Ordering data RF360T RF360T ďˇ ďˇ ďˇ ďˇ IP67 Memory size: 8 KB FRAM (read/write) and 4 byte EEPROM (read only) Operating temperature: -25 °C ⌠+75 °C Dimensions: 85.8 x 54.8 x 2.5 (L x W x H, in mm) Table 6- 8 6.6.3 Order number 6GT2800-4AC00 Ordering data for RF360T accessories RF360T accessories Order number Spacers 6GT2190-0AA00 Fixing pocket 6GT2190-0AB00 Mounting on metal Direct mounting of the RF360T on metal is not allowed. A distance ⼠20 mm is recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with the fixing pocket 6GT2190-0AB00. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 147 RF300 transponder 6.6 SIMATIC RF360T Mounting of RF360T on metal 'DWDVWRUDJHXQLW 0HWDO 1RQPHWDO Figure 6-11 Mounting of RF360T with spacer The standard value for h is ⼠20 mm. Flush-mounting of RF360T in metal: 'DWDVWRUDJHXQLW 0HWDO 1RQPHWDO Figure 6-12 Flush-mounting of RF360T with spacer The standard value for a is ⼠20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. 148 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 RF300 transponder 6.6 SIMATIC RF360T Dimensions of spacer and fixing pocket for RF360T 'LPHQVLRQVNHWFK )L[LQJSRFNHW*7$% 6SDFHUV*7$$ /XJV +ROGLQJNQREV  )L[LQJEUDFNHW 0DWHULDO3$   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r Figure 6-13 7KHWUDQVSRQGHULVLQVHUWHGLQWRWKH IL[LQJSRFNHW7KHHDUVDUHPRYHGE\ rDQGLQVHUWHGLQWRWKHVSDFHU7KH IL[LQJSRFNHW PXVWEHDOLJQHGVXFKWKDWLW FRYHUVWKHWUDQVSRQGHU VHH)LJXUH /RFNLQJLVDXWRPDWLF Dimensions of spacer and fixing pocket for RF360T SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 149
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 50 Page Layout : OneColumn Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:52da04b3-bf05-4fd7-8d86-a1a99b0aa236 Producer : Acrobat Distiller 9.0.0 (Windows) Keywords : Company : SIEMENS AG Comments : Edition : 11/2009 - Zwischenstand 17.09.2009 System : SIMATIC Sensors Print-year : Document-class : System Manual Product-group : RFID systems Order-nr : A5E01642529-04 Ident-nr : Create Date : 2009:11:04 14:14:55+01:00 Creator Tool : Acrobat PDFMaker 9.1 für Word Modify Date : 2009:11:05 11:07:31+01:00 Metadata Date : 2009:11:05 11:07:31+01:00 Document ID : uuid:657bdabf-ff28-4a91-aff2-12a344e8a0da Instance ID : uuid:f252b023-9cd6-4193-a2e4-8bad4184b436 Format : application/pdf Creator : SIEMENS AG Title : SIMATIC RF300 Description : Author : SIEMENS AG Subject :EXIF Metadata provided by EXIF.tools