Siemens RF350R01 RFID System User Manual SIMATIC RF300
Siemens AG RFID System SIMATIC RF300
Siemens >
Contents
- 1. Users Manual 1 of 4
- 2. Users Manual 2 of 4
- 3. Users Manual 3 of 4
- 4. Users Manual 4 of 4
Users Manual 4 of 4
System integration The communication modules (interface modules) are links between the RFID components (reader and transponder) and the higher-level controllers (e.g. SIMATIC S7), or PCs or computers. 8.2 Introduction RF310R, RF340R, RF350R and RF380R readers are connected to the controller via the following interface/communication modules: â ASM 452 â ASM 456 â ASM 473 â ASM 475 â RF170C â RF180C â RF182C â 8xIQ-Sense Function blocks, interface modules/communication modules and readers Function blocks are used for integration into the SIMATIC. Using these, the input parameters are transferred to the reader using the "init_run"(RESET) command. You can find more detailed information on the software parameterization in Product Information "FB 45 and FC 45 input parameters for RF300 and ISO transponders" (http://support.automation.siemens.com/WW/view/en/33315697) or the Function Manual FB 45 (http://support.automation.siemens.com/WW/view/en/21738808) from edition A3 onwards. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 209 System integration 8.2 Introduction Interface modules/communication modules and function blocks The following table shows the most important features of the interface modules/communication modules, as well as the compatible function blocks. Table 8- 1 Overview of interface modules/communication modules ASM/ communicatio n module Interfaces to the application (PLC) Interfaces to the reader Function blocks Reader connections Dimensions (W x H x D) in mm Temperatu re range ASM 452 PROFIBUS DP-V1 2 x 8-pin socket, M12 FC 45 134 x 110 x 55 0 °C to +55 IP67 °C ASM 456 PROFIBUS DP-V1 2 x 8-pin socket, M12 FB 45 FC 55 2 (parallel) * 60 x 210 x 54 0 °C to +55 °C or 79 FC 56 ASM 473 PROFIBUS DP-V1 2 x 8-pin socket, M12 FC 45 Degree of protectio IP67 87 x 110 x 55 0 °C to +55 IP67 °C 40 x 125 x 120 0 °C to +60 IP20 °C FB 45 FC 55 ASM 475 S7-300 (central), ET200M (PROFIBUS) Via screw terminals in front connector FC 45 PROFIBUS DP-V1 2 x 8-pin socket, M12 FB 45 FC 55 2 (parallel) * 90 x 130 x 60 -25 °C to +55° C IP67 SIMATIC RF180C PROFINET IO 2 x 8-pin socket, M12 FB 45 2 (parallel) * 60 x 210 54 0 °C to +60° C IP67 SIMATIC RF182C PROFINET IO 2 x 8-pin socket, M12 __ 2 (parallel) * 60 x 210 x 30 0 to +60 °C IP67 8xIQ-Sense 8xIQ-Sense FC 35 2 (parallel) * 40 x 125 x 120 0 °C to +60 IP20 °C SIMATIC RF170C FB 45 FC 55 PROFINET IO Via screw terminals in front connector *) If 2 readers are used on one ASM, the following restrictions apply: ďˇ The maximum operating temperature is 35 °C ďˇ The input voltage is 24 V Âą10% Current consumption ⤠425 mA per reader 210 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.3 ASM 452 8.3 ASM 452 8.3.1 Features Area of application The ASM 452 interface module is a MOBY module for operating MOBY and RF300 components with RS422 over PROFIBUS DP-V1 on â Any computers and PCs â Any PLCs When operating the interface module on a SIMATIC S7, function blocks are made available to the user. Figure 8-1 Interface module ASM 452 The ASM 452 is the result of consistent development of the familiar ASM 450/451 interface modules. Optimal data throughput can be achieved even in large-scale PROFIBUS configurations thanks to the use of acyclic data traffic on PROFIBUS DP V1. The minimum cyclic data load of the ASM 452 on the PROFIBUS provides the user with the guarantee that other PROFIBUS nodes (e.g. DI/DO) can still be processed at great speed. The ASM 452 is an interface module for communication between PROFIBUS and the RF310R with RS422 interface. Through the ASM 452, the data on the RF300 transponder can be physically addressed ("Normal" addressing). In SIMATIC S7, FC 45 is available for this purpose. 8.3.2 Ordering data Table 8- 2 Ordering data for ASM 452 and accessories Product description Order No. ASM 452 interface module for PROFIBUS DP-V1, 1x RF3xxR with RS422 interface, without connector for 24 V DC and PROFIBUS 6GT2002-0EB20 Accessories: Connector for PROFIBUS DP and 24 V supply 6ES7194-1AA00-0XA0 Connecting cable RF3xxR â ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 211 System integration 8.3 ASM 452 Product description Order No. Plug-in cable, pre-assembled, length: 2 m (standard length) 6GT2891-1CH20 Plug-in cable, pre-assembled, length: 5 m 6GT2891-1CH50 Opt. Cable connector without read/write device cable (for cable lengths > 20 m) ASM 452 â reader 6GT2090-0BC00 M12 blanking cap for unused RF310R connection (1 pack = 10 pieces) 3RX9802-0AA00 CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 Replacement part: Connector plate; T functionality for PROFIBUS connection 6ES7194-1FC00-0XA0 FC 45 Reference Manual German English French Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables. 212 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.3 ASM 452 8.3.3 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignments of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igure 8-2 Pin assignment and LEDs of ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 213 System integration 8.3 ASM 452 8.3.4 Configuration Configuration Hardware description The ASM 452 has the same housing as the distributed I/O system ET 200X. General information on ASM 452 (e.g.: assembly, operation and wiring; general technical data) is available in the ET200X manual (Order No. 6ES7 198-8FA00-8AA0). Descriptions of accessories and network components can also be found in this manual. Configuration 352),%86'3 0DVWHUPRGXOH HJ6&38 352),%86 $60 WRRWKHU352),%86 EXVQRGHV 9IRU $60b HJ 5)5 7DJ0'6 Figure 8-3 Configuration of ASM 452 PROFIBUS configuration The ASM 452 is integrated into the hardware configuration by means of a GSD file. The ASM can then be configured using the HW Config of SIMATIC Manager or another PROFIBUS tool. A GSD file is provided for ASM 452 on the CD "RFID Systems Software & Documentation". 214 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.3 ASM 452 Operating mode of the ASM 452 The approved operating modes of ASM 452 are described in the GSD file. It is set using the hardware configuration tool (e.g. STEP 7 HW Config). Reader connection system A reader always occupies two M12 connector sockets on the ASM 452. A pre-assembled cable therefore ensures easy connection of the reader (see figure below). The connecting cable is available in lengths of 2 m (standard) and 5 m. Extensions are possible up to 1000 m using connecting cables 6GT2891-⌠. $60VLGH 5HDGHUVLGH JUHHQ ; ; ; SLQN ; 7ZRSLQ0 FLUFXODUFRQQHFWRUV ; VKLHOG ; 0SLQ JUD\ ; Figure 8-4 \HOORZ ; ; EURZQ ; ZKLWH Connecting cable (2 m) ASM 452/473 â RF3xxR reader with RS422 (6GT2891-1CH20) Cable installation Signal M12 (reader side) Cable X1 / Data X2 24 V DC Pink TX - Yellow GND Gray TX + Green RX + white RX - brown Shield 8 + terminal piece Shield Cable assignment ASM 452/473 â RF3xxR reader with RS422 (6GT2891-1CH20) A reader cable connector with screw-type terminals is provided for users who want to individually pre-assemble their own cables (see figure below). Cables and reader cable connectors can be ordered from the MOBY catalog. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 215 System integration 8.3 ASM 452 $60FDEOH*7 &RQQHFWRUFRYHUUHPRYHG 3*FDEOHJODQG PD[FDEOHGLDPHWHU PP RQO\VFUHZGRZQ DIWHUDVVHPEOLQJWKH FRQQHFWRU VFUHZV IRURSHQLQJ WKHFRQQHFWRU 'HJUHHRISURWHFWLRQ,3 Figure 8-5 &RQQHFWRU 0WR$60 Cable connector ASM 452/473 â RF3xx reader with RS422 (6GT2090-0BC00) Pin assignment for ASM 452/473 cable connector Connector pin Connection to pin of the reader Wire color Note data sheet provided by the manufacturer 8 + terminal piece Pin 7 must not be connected. PROFIBUS cable with 24 V supply The ASM 452 can also be operated with the "green" PROFIBUS cable. It is important to ensure that a 24 V cable is connected from X12 to X13. The 24 V cable can be connected to pins 5 and 6 in plug X12. ; ; Figure 8-6 216 ; ; ; ; PROFIBUS cable with 24 V supply SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.3 ASM 452 PROFIBUS address and terminating resistor You must remove the connector plate from the ASM before you set the PROFIBUS address or connect the terminating resistor. The connector plate covers the DIL switch. The position of the DIL switch in ASM is shown in the figure below with one setting example for each case. ([DPSOH7HUPLQDWLQJUHVLVWRU2II $VGHOLYHUHGVWDWH RQ 2II ([DPSOH352),%86DGGUHVV RQGHOLYHU\ 21 Figure 8-7 6WDQGDUG PRGH XVH*6'ILOH 6,(0% Setting the PROFIBUS address/connecting the terminating resistor Note ďˇ The PROFIBUS address in ASM 452 must always match the PROFIBUS address defined in the configuring software for this ASM. ďˇ To ensure that the terminating resistor functions correctly, you must always switch both DIL switches of the terminating resistor to "on" or "off". 8.3.5 Technical data Table 8- 3 Technical data for ASM 452 Serial interface to the user PROFIBUS DP-V1 Procedure after connection EN 50170 Vol. 2 PROFIBUS PG 11 cable gland PROFIBUS and power supply connectors are not included in the scope of delivery Transmission rate 9600 baud to 12 Mbaud (automatic detection) Max. block length 2 words cyclic/240 bytes acyclic Serial interface to the RF3xxR Connector 2 x M12 coupler plug Max. cable length 2 m = Standard length, 5 m, 10 m, 20 m and 50 m, (up to 1000 m on request) Readers that can be connected 1x RF3xxR with RS422 interface SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 217 System integration 8.3 ASM 452 Software functions Programming Depending on the PROFIBUS DP master Function blocks for SIMATIC S7 FC 45 Transponder addressing Direct access via addresses Commands Initialize transponder, read data from transponder, write data to transponder Multi-tag capability No S7 data structures via UDTs Yes Power supply Rated value 24 V DC Permissible range 20 V to 30 V DC Current consumption Max. 180 mA; typ. 130 mA (without reader) Digital inputs none Digital outputs none Ambient temperature 8.3.6 Operation 0 °C to +55 °C Storage and transport -40 °C to +70 °C Dimensions (W x H x D) in mm 134 x 110 x 55 (without bus connector) Fixing 4 M5 screws; for mounting on any plate or wall Weight, approx. 0,5 kg Degree of protection IP67 MTBF (at 40 °C) 30 ⢠104 hours = 34 years PROFIBUS Diagnosis The following table lists possible error indications with their meanings and provides remedies. Table 8- 4 LED indication for PROFIBUS diagnosis "BF" LED "SF"LED Cause of error ON ďˇ ASM 452 is in start-up mode. ďˇ The connection to the DP master ďˇ has failed. ASM 452 not detecting a baud ďˇ rate. Check the PROFIBUS DP connection. Check the DP master. Bus interrupt DP Master not functioning Check all cables on your PROFIBUS DP network. Check whether the connector plugs for PROFIBUS DP are securely plugged into the ASM 452. ďˇ ďˇ ďˇ 218 Error correction ďˇ ďˇ SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.3 ASM 452 "BF" LED "SF"LED Cause of error flashes on ďˇ Flashes Off ďˇ ďˇ on 8.3.7 Flashes ďˇ Error correction The configuration data sent to the ASM 452 by the DP master do not match the configuration of the ASM 452. ďˇ ASM 452 has detected the baud rate, but is not being addressed by the DP Master. ASM 452 has not been configured. ďˇ Check the configuration of the ASM 452 (input/output, PROFIBUS address). Correct GSD file being used? â SIEM80B6.GSD for ASM 452 ďˇ Check the PROFIBUS address set on the ASM 452 or in the configuration software. Check the configuration of the ASM 452 (station type). ďˇ There is a hardware defect in the ďˇ ASM 452. Replace the ASM 452. Dimension drawing The following figure shows the dimensional drawing of an ASM 452 with bus connectors. You must add the length of the PG cable gland and the radius of the cable used to the measured overall width and depth.  Figure 8-8 Dimensional drawing of ASM 452 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 219 System integration 8.4 ASM 456 Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQG WUXQFDWHG VKLHOGEUDLGLQJ Figure 8-9 8.4 Length of stripped insulation for PROFIBUS cables ASM 456 Configured with ASM 456 352),%86'3 0DVWHUPRGXOH 6,0$7,&b6 $60b 352),%86 9IRU $60DQGUHDGHU HJ 5)5 HJ 5)5 9WRRWKHU352),%86 EXVQRGHV WRRWKHU352),%86 EXVQRGHV 7DJV0'6 Figure 8-10 7DJV0'6 Configuration of ASM 456 For more detailed information, please refer to ASM 456 Operating Instructions (http://support.automation.siemens.com/WW/view/en/32629442). 220 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.5 ASM 473 8.5 ASM 473 8.5.1 Features Field of application The ASM 473 interface module is an RF300 module for SIMATIC S7. It can be plugged into the ET 200X distributed I/O station and DESINA. ET 200X is operated by the user over PROFIBUS DP V1. An S7-300 or S7-400 with integrated PROFIBUS connection can be used as the controller. ASM 473 supplements the SIMATIC S7 interface module ASM 475. The IP67 degree of protection means that it can be installed and operated in the process without the need for an additional protective housing. To operate the ASM 473, an ET 200X basic module BM 141/142 with the order number 6ES7141-1BF11-0XB0 or 6ES7142-1BD21-0XB0 or a BM 143 is required. The transponder data are accessed by means of physical addressing of the transponder. For operation in a SIMATIC S7, the function FC 45 is available. The hardware of the ASM 473 is configured with an object manager (OM) that is integrated in the SIMATIC Manager. Figure 8-11 Interface module ASM 473 Other features: â Up to 7 ASM 473 interface modules can be operated simultaneously in an ET 200X station. â Any other I/O modules from the ET 200X spectrum can be operated with the ASM 473. 8.5.2 Ordering data Table 8- 5 Ordering data for ASM 473 and accessories Product description Order No. Interface module ASM 473 1x RF3xxR reader with RS422 interface 6GT2002-0HA10 Accessories: SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 221 System integration 8.5 ASM 473 Product description Order No. Connecting cable ASM 473 â Reader RF3xxR Plug-in cable, pre-assembled, length 2 m (standard length) 6GT2891-1CH20 Plug-in cable, pre-assembled, length 5 m 6GT2891-1CH50 Opt. Cable connector without reader cable 6GT2090-0BC00 (for cable lengths > 20 m) ASM 473 â Reader CD "RFID Systems Software & Documentation" with FC 45, GSD file 6GT2080-2AA10 FC 45 Reference Manual German English French 222 Available in electronic form on the CD "RFID Systems Software & Documentation" SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.5 ASM 473 8.5.3 Pin assignment and display elements Pin assignments The figure below illustrates the pin assignment for the read/write device and the display elements. 6RFNHW 3LQDVVLJQPHQW UHDGHU ; 5[' 7[' 7[' 5[' 3( ; 9 QF 9 QF 3( /('VIRU352),%86'3 *HQHUDOLQGLFDWRUV 6)%)219'& DUHORFDWHGRQWKHEDVLFPRGXOH RIWKH(7; /('VIRU02%< 5[' 35( (55 5HDGHUDFWLYHZLWKFRPPDQG ,QGLFDWHVWKHSUHVHQFHRIDWUDQVSRQGHU (UURULQGLFDWHGE\IODVKLQJVHTXHQFH 7KHIROORZLQJ$60VWDWHVDUHDOVRLQGLFDWHGZLWKWKH/('V35(DQG (55 35( (55 'HVFULSWLRQ&DXVHV5HPHG\ 2))21 21 SHUP +DUGZDUHLVGHIHFWLYH 5$0IODVK 21 2)) &KDUJHULVGHIHFWLYH FDQRQO\EHUHSDLUHGLQWKH IDFWRU\ +] 2)) )LUPZDUHORDGLQJLVDFWLYHRUQR ILUPZDUHGHWHFWHG ŕľş/RDGILUPZDUH ŕľş$60PXVWQRWEHVZLWFKHGRIIXQWLOORDGHG +] +] )LUPZDUHORDGLQJWHUPLQDWHGZLWKHUURUV ŕľş5HVWDUWUHTXLUHG ŕľş/RDGILUPZDUHDJDLQ ŕľş&KHFNXSGDWHILOHV +] +] 2SHUDWLQJV\VWHPHUURU ŕľş6ZLWFK$60RU(7;EDVHVWDWLRQ2))21 2)) [IODVK HYHU\V $60KDVERRWHGDQGLVZDLWLQJIRUD5(6(7 LQLWBUXQ IURPWKHXVHU Figure 8-12 Interfaces and indicators of the ASM 473 for RF300 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 223 System integration 8.5 ASM 473 8.5.4 Configuration 352),%86'3 0DVWHUPRGXOH 6,0$7,&b6 %DVLFPRGXOH (7;%0 (7;%0 (7;%0 '(6,1$%0 $60b 352),%86 WRRWKHU352),%86 EXVQRGHV 9VXSSO\ IRU(7; (OHFWURQLFV HJ 5)5 9VXSSO\ )RUUHDGHU 0'67DJ Figure 8-13 Configuration of ASM 473 Note It differs from ASM 452 in that for ET 200X the 24 V supply must be connected to the PROFIBUS connector and on the load voltage connector (see the ET 200X manual). Basic module - Requirements for operation of ASM 473 The following table indicates the status of the ET 200X basic module of 10/2002. The functionality of new basic modules is stored in HW Config of the SIMATIC Manager. Table 8- 6 224 Requirements for operation of ASM 473 Order number of the ET 200X basic module For operation with ASM 473 (6GT2002-0HA00)* For operation with ASM 473 PARAM (6GT2002-0HA10) 6ES7141-1BF00-0XB0 No No 6ES7141-1BF00-0AB0 Yes Yes 6ES7141-1BF01-0XB0 No No 6ES7141-1BF10-0XB0 No No SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.5 ASM 473 Order number of the ET 200X basic module For operation with ASM 473 (6GT2002-0HA00)* For operation with ASM 473 PARAM (6GT2002-0HA10) 6ES7141-1BF11-0XB0 Yes Yes 6ES7141-1BF40-0AB0 Yes Yes 6ES7142-1BD10-0XB0 No No 6ES7142-1BD11-0XB0 No No 6ES7142-1BD20-0XB0 No No 6ES7142-1BD21-0XB0 Yes Yes 6ES7142-1BD22-0XB0 No Yes** 6ES7143-1BF00-0AB0 Yes Yes 6ES7143-1BF00-0XB0 Yes Yes 6ES7147-1AA00-0XB0 No No 6ES7147-1AA01-0XB0 No Yes * Discontinued ** Notes on operation: In HW Config, please parameterize the module 6ES7142-1BD21-0XB0. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 225 System integration 8.5 ASM 473 Example for a maximum configuration of ASM 473 on an ET 200X 0D[$60FDQEHRSHUDWHGLQDQ(7; 6,0$7,& 6,0$7,& 6,0$7,& 6,0$7,& 6,0$7,& 6,0$7,& 6,0$7,& 5)5 5)5 5)5 5)5 5)5 5)5 5)5 5)[[5 5)[[7 6,0$7,& 5)7 Figure 8-14 Example for a maximum configuration of ASM 473 on an ET 200X Depending on the PROFIBUS master, up to 123 ET 200X modules can be run on one PROFIBUS branch. Hardware configuration The ASM 473 is integrated in the hardware configuration of the SIMATIC Manager by calling Setup.exe in the directory daten\S7_OM on the "RFID Systems Software & Documentation" CD. Currently, the ASM 473 cannot be integrated in masters of other manufacturers. Reader connection system A reader always occupies the two M12 connection sockets X3 and X4 on the ASM 473. A prefabricated cable makes it easy to connect the reader. The standard version of the connecting cable is 2 m in length. Other cable lengths are available on request. For customers who want to assemble their own cables, an ASM cable connector with screw- 226 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.5 ASM 473 type terminals is available. Cables and ASM cable connectors can be ordered from the MOBY catalog. 8.5.5 Technical data Table 8- 7 Technical specifications for ASM 473 Interface for ET 200X SIMATIC S7 I/O bus cyclic/acyclic services Communication 2 words cyclic/238 bytes acyclic Command buffer in ASM 142 x 238 bytes Serial interface to the reader ďˇ Connector 2 x M12 coupler plug ďˇ Max. cable length 2 m = standard length; other pre-assembled cables = 5 m, (up to 1000 m on request) ďˇ Readers that can be connected 1 x RF3xxR reader with RS422 Software functions Programming Depending on the PROFIBUS DP master Function blocks for SIMATIC S7 FC 45, FB 45, FC 55 MDS addressing Direct access via addresses Commands Initialize transponder, read data from transponder, write data to transponder, etc. PROFIBUS Diagnosis Yes; in accordance with ET 200X basic station S7 diagnostics Yes, can be called up via S7 OM Reloadable firmware Yes, via S7 OEM Power supply ďˇ Rated value 24 V DC ďˇ Permissible range 20.4 V to 28.8 V DC Current consumption Typ. 75 mA; max. 500 mA (or see Technical specifications of the connected reader) Power dissipation of the module Typically 1.6 W Digital outputs/inputs Via expansion modules from the ET 200X spectrum Ambient temperature ďˇ Operation 0 °C to +55 °C ďˇ Transport and storage -40 °C to +70 °C Dimensions (W x H x D) in mm ďˇ Single unit 87 x 110 x 55 ďˇ Width module 60 x 110 x 55 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 227 System integration 8.5 ASM 473 Fixing 2 M5 screws (customer side) 2 M3 screws (product side) Degree of protection IP67 Weight, approx. 0.275 kg For installation instructions and general technical data, see the ET 200X manual. 8.5.6 Dimensional drawings Dimension drawing for mounting holes The figure below shows the dimensions for the position of the holes for the fixing screws for a basic module and an ASM 473 expansion module. Q[ )RU0IL[LQJ VFUHZ %0 $60b Q 1XPEHURIH[SDQVLRQPRGXOHV Figure 8-15 Dimensions for fixing holes for basic modules and expansion modules Example of stripped lengths The following diagram shows an example of stripped lengths. The lengths apply to all cables which can be connected to the connector plugs. You must twist any shield braid present, plug into a core end sleeve and cut off any excess. 7ZLVWHGDQG WUXQFDWHG VKLHOGEUDLGLQJ Figure 8-16 228 Length of stripped insulation for PROFIBUS cables SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.6 ASM 475 8.6 ASM 475 8.6.1 Features Area of application The ASM 475 interface module acting as the link between all RF300 systems and SIMATIC S7-300 performs the functions of a communication module. It can be operated centrally in the S7-300 or decentrally in an ET200M. As many as eight ASM 475 interface modules can be plugged into one SIMATIC S7-300 rack and operated. In a configuration with several racks (max. four), the ASM 475 can be plugged into and operated on any rack. This means that as many as 32 ASMs can be operated in the maximum configuration of a SIMATIC S7-300. The ASM can also be operated in the ET 200M distributed I/O on PROFIBUS. Operation in an S7-400 environment is therefore problem-free. Up to 8 ASMs can be operated on each ET200M. Error messages and operating states are indicated by LEDs. A configuration that is resistant to interference is possible due to electrical isolation between the read/write device and the SIMATIC S7-300 bus. Figure 8-17 Interface module ASM 475 The ASM 475 with the order number 6GT2002-0GA10 is a parameterizable module. The basic functions of the module are then already specified when the module is configured in HW Config (e.g. standard addressing). The data in the MDS is accessed direct by means of physical addresses using the ASM 475. Operation in a SIMATIC S7 is controlled by the function FC 45. ASM 475 and FC 45 form a unit that is used for reading the data of the MDS easily and at optimal speed. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 229 System integration 8.6 ASM 475 8.6.2 Ordering data Table 8- 8 Ordering data for ASM 475 and accessories Product description Order No. ASM 475 interface module for SIMATIC S7 6GT2002-0GA10 2 x RF3xxR reader with RS422 can be connected in parallel, without front connector Accessories: Front connector (1 x per ASM) 6ES7392-1AJ00-0AA0 Connecting cable ASM 475 â RF3xxR Plug-in cable, pre-assembled, length: 2 m (standard length) 6GT2891-0EH20 Plug-in cable, pre-assembled, length: 5 m 6GT2891-0EH50 Terminal element (1 x per reader cable) 6ES7390-5BA00-0AA0 Shield connecting element 6ES7390-5AA00-0AA0 CD "RFID Systems Software & Documentation" with FC 45, S7 object manager 6GT2080-2AA10 FC 45 Reference Manual German English French Available in electronic form on the CD "RFID Systems Software & Documentation" The ASM 456 plug-in cables 6GT2891-0Fxxx can be used as extension cables. 230 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.6 ASM 475 8.6.3 Indicators Bezel and indicator elements The figure below illustrates the bezel of the ASM 475 and the inside of the front door complete with the associated connection diagram. The read/write devices must be connected to the ASM in accordance with the connection diagram. 02%< $60 6) 9'& (55B 6 35(B 6 5['B ( ( 6/*b $&7B ( ( (55B 35(B 6/*b 6 6 $&7B 5['B *7b*$ 6WDWXVDQGHUURUGLVSOD\V Figure 8-18 &RQQHFWLRQGLDJUDP 7KHQXPEHUVRIWKH FRQQHFWLRQVUHIHUWR &RQQHFWRU;RIWKH WRSHQFORVXUHVHFWLRQ Bezel and inside of the front door of the ASM 475 Display elements on the ASM Table 8- 9 Function of the LEDs on the ASM 475 Light emitting diode Meaning SF System fault (hardware error on ASM) DC 5V 24 V are connected to ASM and the 5 V voltage on ASM is OK. ACT_1, ACT_2 The corresponding reader is active in processing a user command. ERR_1, ERR_2 A flashing pattern indicates the last error to occur. This display can be reset using the parameter Option 1. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 231 System integration 8.6 ASM 475 Light emitting diode Meaning PRE_1, PRE_2 Indicates the presence of a transponder. RxD_1, RxD_2 Indicates live communication with the reader. In the event of a fault on the reader, this display may also be lit. On the ASM 475, further operating states are indicated with the LEDs PRE, ERR and SF: Table 8- 10 232 Operating status display on ASM 475 via LEDs SF PRE_1 ERR_1 PRE_2 ERR_2 Meaning ON OFF/ON ON (perm.) OFF/ON ON (perm.) Hardware is defective (RAM, Flash, etc.) ON OFF ON OFF OFF Charger is defective (can only be repaired in the factory). OFF 2 Hz OFF 2 Hz OFF Firmware loading is active or no firmware detected ďˇ Firmware download ďˇ ASM must not be switched off OFF 2 Hz 2 Hz 2 Hz 2 Hz Firmware loading terminated with errors ďˇ Restart required ďˇ Load firmware again ďˇ Check update files Any value 5 Hz 5 Hz 5 Hz 5 Hz Operating system error ďˇ Switch ASM off/on OFF OFF 1 flash every 2 s OFF 1 flash every 2 s ASM has booted and is waiting for a RESET (init_run) from the user. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.6 ASM 475 8.6.4 Configuration Centralized configuration with SIMATIC S7-300 352),1(7b,2 0DVWHUPRGXOH 6,0$7,&b6 $60b $GGLWLRQDOPRGXOHVIURPWKH 6UDQJH LQFO$60 6 $60 FKDQQHO $60 FKDQQHO HJ 5)5 HJ 5)5 7DJV0'6 Figure 8-19 Configuration of ASM 475 central SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 233 System integration 8.6 ASM 475 Distributed configuration with ET200M HJLQWHUIDFHPRGXOH $60b $GGLWLRQDOPRGXOHVIURPWKH 6UDQJH LQFO$60 (70 $60 FKDQQHO $60 FKDQQHO HJ 5)5 HJ 5)5 7DJV0'6 Figure 8-20 Configuration of ASM 475 distributed Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables. $60VLGH 5HDGHUVLGH &DEOHZLWKHQGVOHHYHV JUD\ SLQN \HOORZ EURZQ ZKLWH JUHHQ VKLHOG 6/*FRQQHFWRU 6RFNHW 0SLQ &DEOHVKLHOGH[SRVHG *7(ZLWKVWUDLJKW6/*FRQQHFWRU VWDQGDUG Figure 8-21 234 Installation of connecting cable between ASM 475 and RF300 reader with RS 422 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.6 ASM 475 Cable installation Signal Pin on M12 connector Cable Labeling 24 V DC white 1 Reader 2 8 -16 TX - brown 1 Reader 2 7-15 GND Green 1 Reader 2 9-17 TX + Yellow 1 Reader 2 RX + Gray 1 Reader 2 RX - Pink 1 Reader 2 6-14 4-12 5-13 Shield 8 + terminal piece Cable assignment for connection of an RF300 reader to ASM 475 8.6.5 Technical data Table 8- 11 Technical data for ASM 475 Serial interface for SIMATIC S7-300 or ET200M I/O bus; cyclic and acyclic services Communication 2 words cyclic/238 bytes acyclic Command buffer in ASM 475 70 x 238 bytes per RF310R reader Serial interface to the reader Connector Via screw-type terminal on front connector The front connector is not included in the scope of supply. Max. cable length Pre-assembled cables = 2 m, 5 m, (up to 1000 m on request) Readers that can be connected 2 x RF3xxR reader with RS422 parallel mode Software functions Programming Depending on the PROFIBUS DP master Function blocks for SIMATIC S7 FC 45; FB 45; FC 55 Transponder addressing Direct access via addresses Commands Initialize transponder, read data from transponder, write data to transponder SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 235 System integration 8.6 ASM 475 Multitag mode No S7 data structures via UDTs Yes Power supply Rated value 24 V DC Permissible range 20.4 V to 28.8 V DC Current consumption Without reader for U = 24 V DC, max. 350 mA With reader connected, max. 500 mA, per connected reader Power dissipation of the module, typ. 2 Watts Current consumption from I/O bus, max. 80 mA Electrical isolation between S7-300 and RF300 Yes Fuse 24 V for the reader Yes, electronic Ambient temperature 236 During operation Horizontal installation of SIMATIC Vertical installation of SIMATIC 0 to +60 °C 0 to +40 °C Transport and storage -40 to +70 °C Dimensions (W x H x D) in mm 40 x 125 x 120 Weight, approx. 0.2 kg SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.7 RF170C 8.7 RF170C Configured with RF170C PROFIBUS or PROFINET/Industrial Ethernet Master module SIMATIC S7 PROFINET/ Industrial Ethernet or Interface module ET 200pro SIMATIC RF170C PROFIBUS 9IRU (7SUR5)& DQGUHDGHU HJ 5)5 HJ 5)5 7DJV0'6 Figure 8-22 Configuration of RF170C For more detailed information, refer to SIMATIC RF170C Operating Instructions (http://support.automation.siemens.com/WW/view/en/32622825). SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 237 System integration 8.8 RF180C 8.8 RF180C Configured with RF180C 352),1(7b,2 0DVWHUPRGXOH 6,0$7,&b6 6,0$7,& 5)& 352),1(7 ,QGXVWULDO(WKHUQHW ]% 5)5 9IRU 5)&DQGUHDGHU ]% 5)5 9WRRWKHU 352),1(7EXVQRGHV WRRWKHU352),1(7 EXVQRGHV Figure 8-23 7DJV0'6 Configuration of RF180C For more detailed information, refer to SIMATIC RF180C Operating Instructions (http://support.automation.siemens.com/WW/view/en/30012157). 238 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.9 RF182C 8.9 RF182C Configuration with RF182C PROFINET IO Master module SIMATIC S7 3& 6,0$7,& 5)& 352),1(7,2 ,QGXVWULDO(WKHUQHW 9IRU 5)&DQGUHDGHU ]% 5)5 ]% 5)5 7RDGGLWLRQDO352),1(7(WKHUQHWQRGHV 7DJV0'6 Figure 8-24 Configuration with RF182C For more detailed information, refer to SIMATIC RF182C Operating Instructions (http://support.automation.siemens.com/WW/view/en/38507897). SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 239 System integration 8.10 8xIQ-Sense 8.10 8xIQ-Sense 8.10.1 Features Field of application The 8xIQ-Sense module is the link between the RF310R with 8xIQ-Sense interface and SIEMENS S7-300 and functions in the same manner as the communication module (interface module). It can be operated centrally in an S7-300 or decentrally in an ET200M. Figure 8-25 8.10.2 8xIQ-Sense interface module Ordering data Table 8- 12 Ordering data for 8xIQ-Sense and accessories Order number ďˇ ďˇ IQ-Sense SM338 for S7-300 and ET200M for the connection of up to 8xIQ-Sense sensors Optical sensors, ultrasonic sensors and RF identification systems can be connected. Table 8- 13 6ES7 3387XF000AB0 Ordering data for 8xIQ-Sense accessories Order number 240 M12 cable plug, 4-pole, with 5 m black PUR cable, 4 x 0.34 mm2 3RX8000-0CB42-1AF0 M12 cable plug, 4-pole, with 10 m black PUR cable, 4 x 0.34 mm2 3RX8000-0CB42-1AL0 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.10 8xIQ-Sense 8.10.3 Indicators Status displays The 8xIQ-Sense module has the following LEDs: A green LED, which has no function for RFID devices, and a red SF LED (system fault LED), which indicates the diagnostic state of the module. LEDs 60 [,46HQVH 6) Labeling LED status Meaning Green 0âŚ7 LED per channel Has no function here Red Illuminate Module fault, sensor fault, active teach-in operation, external auxiliary voltage missing SF No fault or no active teach-in Not illuminate operation ; ;)$% SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 241 System integration 8.10 8xIQ-Sense 8.10.4 Configuration Centralized configuration with SIMATIC S7-300 [,46HQVH $GGLWLRQDOPRGXOHVIURPWKH 6UDQJH LQFO[,46HQVH 6 $60 FKDQQHO $60 FKDQQHO 5HDGHUZLWK [,46HQVH LQWHUIDFH 5HDGHUZLWK [,46HQVH LQWHUIDFH 7DJV0'6 Figure 8-26 242 Configuration of 8xIQ-Sense central SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.10 8xIQ-Sense Distributed configuration with ET 200M HJLQWHUIDFHPRGXOH [,46HQVH $GGLWLRQDOPRGXOHVIURPWKH 6UDQJH LQFO[,46HQVH (70 $60 FKDQQHO $60 FKDQQHO 5HDGHUZLWK [,46HQVH LQWHUIDFH 5HDGHUZLWK [,46HQVH LQWHUIDFH 7DJV0'6 Figure 8-27 Configuration of 8xIQ-Sense distributed Table 8- 14 Pin assignment of RF310R with IQ-Sense interface Pin Pin, device end, 4-pin M12 Assignment IQ-Sense Not used IQ-Sense Not used SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 243 System integration 8.10 8xIQ-Sense Configuration of connecting cable from 8xIQ-Sense to RF310R 5HDGHU6HLWH ,46HQVH6HLWH EUDXQ 6/*6WHFNHU 0%XFKVH EODX Figure 8-28 8.10.5 Cable and pin assignment of RF300 with IQ-Sense Addressing The address range of the 8xIQ-Sense module is 16 bytes I/O. This is independent of the choice of channel profiles on the connected device (i.e. the IQ profile IDs in HW Config). Access to memory areas A direct association exists between the number of the channel to which the IQ-Sense device is connected (terminal) and the input and output data area of the module. Based on the address range, the following addresses can be used to access the memory areas: Address = module initial address + (channel no. x 2) Example Module initial address = 280 I/O address for channel 3: 286 244 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System integration 8.10 8xIQ-Sense &KDQQHODGGUHVVHV LQH[DPSOH 7HUPLQDO 0 5)5 ,46HQVHGHYLFH ,46HQVHGHYLFH ,46HQVHGHYLFH ,46HQVHGHYLFH 0 ಌ 0 0 ಌ 0 0 ಌ )URQW GRRULQWHULRU &KDQQHOQR IRU,46HQVHGHYLFHV / ,4 FKDQQHO FKDQQHO FKDQQHO FKDQQHO FKDQQHO FKDQQHO FKDQQHO FKDQQHO 0 0 ಌ IRU5) ,4 ,4 ,4 ,46HQVHGHYLFH 5)5 ,46HQVHGHYLFH ,46HQVHGHYLFH 0 0 ಌ 0 0 ಌ 0 0 ಌ ,46HQVHGHYLFH 0 0 ಌ ,4 ,4 ,4 ,4 Figure 8-29 8xIQ-Sense module: Assignment of terminal pair to memory area Note A maximum of two read/write devices can be operated! Each read/write device uses channel numbers 0 to 3 or 4 to 7. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 245 System integration 8.10 8xIQ-Sense 8.10.6 Technical data Voltages and currents Rated supply voltage 24 V DC Reverse polarity protection yes Galvanic isolation ďˇ Between the channels ďˇ Between channels and backplane bus no yes Permissible potential difference Between different circuits 75 V DC / 60 V AC Insulation tested at 500 V DC Current input ďˇ from the backplane bus ďˇ from L+ power supply 120 mA typical Module power loss 2.5 W typical 500 mA max. Module-specific data Number of channels Channels for RFID systems Cable length, unshielded 50 m max. Dimensions and weight 246 Dimensions w x h x d (mm) 40 x 125 x 120 Weight Approx. 235 g SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 9 System diagnostics 9.1 Error codes Error codes of the RF300 readers Flashing of red Error code LED on reader (hexadecimal) Description 00 00 no error 02 01 Presence error, possible causes: ďˇ The active command was not carried out completely ďˇ The tag has left the field while the command is being processed ďˇ Communication fault between reader and tag 05 05 Parameterization error, possible causes: ďˇ Unknown command ďˇ Incorrect parameter ďˇ Function not allowed 06 06 Air interface faulty 12 0C The tag memory cannot be written, possible causes: ďˇ Hardware fault (memory faulty) ďˇ Memory write-protected (corresponding OTP area has already been written) 13 0D Error in the specified memory address (access attempted to nonexistent or non-accessible memory areas). 19 13 Buffer overflow: Insufficient buffer available in the reader for saving the command 20 14 Major system fault (hardware fault) 21 15 Parameter assignment error: faulty parameter in RESET command 25 19 Previous command is still active 28 1C Antenna is already switched off/Antenna is already switched on 30 1E Incorrect number of characters in frame 31 1F Running command cancelled by "RESET" command SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 247 System diagnostics 9.2 Diagnostics functions 9.2 Diagnostics functions 9.2.1 Overview Extended diagnostic functions with SIMATIC RF300 @ FB 45-Tabellen mĂźssen noch hier reinverlinkt werden With SIMATIC RF300, extended diagnostic functions are available which simplify commissioning and maintenance. This diagnostics data is accessed using the SIMATIC function blocks via the SLG Status and MDS Status commands. These two commands can each be called in various modes (subcommands) for which corresponding data structures (UDTs) are defined. Table 9- 1 In RF300 mode Command Mode (subcommand) Meaning SLG status 01 Hardware and firmware configuration, parameterization status MDS status 06 Communication error counter, current command status 01 Serial number of the tag (UID), memory configuration EEPROM write-protection status 02 Serial number of the tag (UID), HF field strength value, communication error counter, presence counter (duration) Overview of the diagnostic functions Table 9- 2 9.2.2 In ISO mode Command Mode (subcommand) Meaning SLG status 01 Hardware and firmware configuration, parameterization status MDS status 03 Serial number of the tag (UID), recognized tag type in the field (number = tag - type, see reset parameter "ftim"), memory configuration, write protect status (OTP), size and number of blocks in the user memory Reader diagnostics with SLG Status The SLG STATUS command can be used to scan the status and diagnostics data of the reader. 248 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System diagnostics 9.2 Diagnostics functions SLG STATUS (mode 01), corresponds to UDT 110 Name Type Possible values Comment hardware char (31 to 38 hex) Type of hardware hardware_version word loader_version HW version 0 to FF hex = Version (high byte): Unused 0 to FF hex = Version (low byte) Version of loader word 0 to FF hex firmware char firmware_version word driver 0 to FF hex = Version (low byte) 0 to FF hex Type of firmware Firmware version 0 to FF hex = Version (high byte) 0 to FF hex = Version (low byte) char Type of driver 31 hex driver_version interface baud distance_limiting_SLG 3964R Version of driver word 0 to FF hex = Version (high byte) 0 to FF hex = Version (low byte) Interface type byte 01 hex = RS422 02 hex = RS232 (only RF380R) Baud rate byte byte = Version (high byte) 01 hex = 19.2 Kbaud 03 hex = 57.6 Kbaud 05 hex = 115,2 Kbaud This variable is only provided for the RF380R. Users are therefore able to check the output power actually set. An incorrect value in the parameter "distance_limiting" of the RESET message frame results in the default setting "05". Transmit power multitag_SLG 02 hex 0.5 W 03 hex 0.75 W 04 hex 1,0 05 hex 1.25 W (default) 06 hex 1.5 W 07 hex 1.75 W 08 hex 2.0 W Number of MDSes (Multitag/Bulk) that can be processed in the antenna field byte 01 hex = Single tag mode SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 249 System diagnostics 9.2 Diagnostics functions Name Type Possible values Comment field_ON_time_SLG byte 00 hex RF300 transponder 01 hex ISO transponder (non-specific) 03 hex ISO my-d (Infineon SRF 55V10P) 04 hex ISO (Fujitsu MB89R118) 05 hex ISO I-Code SLI (Philips SL2 ICS20) 06 hex Tag-it HFI (Texas Instruments) 07 hex ISO (ST LRI2K) status_ant MDS_control Status of antenna byte 01 hex = Antenna On 02 hex = Antenna Off Presence mode byte 00 hex = Operation without presence message 01 hex = Operation with presence message SLG STATUS (mode 06), corresponds to UDT 280 Name Type Possible values Comment FZP byte 0 to FF hex = Error counter, passive (errors during idle time) ABZ byte 0 to FF hex = Abort counter CFZ byte 0 to FF hex = Code error counter SFZ byte 0 to FF hex = Signature error counter CRCFZ byte 0 to FF hex = CRC error counter BSTAT byte 0 to FF hex = Current command status ASMFZ byte 0 to FF hex = Interface problems to host (ASM/PC) parity, BCC, frame error Note All counter values are reset after reading (= SLG STATUS command executed). Explanations: â "FZP": Counts interference pulses when communication is not taking place with a transponder. (e.g. EMC interference caused by contactors, motors, etc.). However, counter values can also be generated when a tag is located at the edge of the field even when there is no external interference. â "ABZ", "CFZ", "SFZ" and "CRCFZ" are counters for protocol errors which may occur during reader-tag communication. This can be caused by unsuitable reader/tag positioning (e.g. tag on field boundary, several data carriers in the field) or an external electromagnetic interference. To ensure clear diagnosis of the quality of communication, it is recommended that an SLG STATUS command (mode 06) is executed following receipt of the presence command to reset the error counter. 250 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System diagnostics 9.2 Diagnostics functions The protocol error counters are not mutually independent. If a code error (CFZ) occurs, this will cause a signature (SFZ) or CRC- (CRCFZ) error. â "BSTAT" is the status for the most recently executed command. A value other than 0 means that the previous command was repeated by the reader due to faults (see above). â "ASMFZ" signals line-conducted communication interference between the communication module (ASM) and the reader. Faults of this type can be caused by contact problems on the connector or the cable connection. 9.2.3 Transponder diagnostics with MDS Status The MDS STATUS command can be used to scan the status and diagnostics data of the transponder that is located within the antenna field. MDS Status (mode 01), corresponds to UDT 260, only for RF300 tags Name Type UID array[1âŚ8] byte Possible values Unique identifier 0000000055555555 hex to 00000000 FFFFFFFF hex MDS_type Lock_state = b0-31: 4 byte TAG ID, b32-63: 0 Tag memory configuration byte byte Comment 01 hex = Transponder without FRAM 02 hex = Transponder with FRAM 8 KB 03 hex = Transponder with FRAM 32 KB 04 hex = Transponder with FRAM 32 KB 0 to FF hex EEPROM write protection status (use graphic from UDT260 here) MDS Status (mode 02), corresponds to UDT 270, only for RF300 tags Name Type UID array[1âŚ8] byte Possible values Comment Unique identifier 0000000055555555 = b0-31: 4 byte TAG ID, b32-63: 0 hex to 00000000FFFFFFFF hex LFD byte 0 to FF hex = Value for field strength determined in the tag FZP byte 0 to FF hex = Error counter (passive) â errors during idle time FZA byte 0 to FF hex = Error counter (active) ANWZ byte 0 to FF hex = Presence counter SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 251 System diagnostics 9.2 Diagnostics functions Note All counter values are reset when the tag exits the field or when the antenna is switched off. Explanations: â "LFD" is a value for the field strength that is determined in the transponder. The lower the value, the higher the field strength. â "FZP" counts fault pulses when communication with a transponder is not taking place (e.g. electromagnetic interference caused by contactors, motors, etc.). Counter values can also be generated when a transponder is located at the edge of the field even when there is no external interference. â "FZA" counts errors that can occur during reader-to-transponder communication. This can be caused by unsuitable reader/transponder positioning (e.g. transponder on field boundary, several data carriers in the field) or external electromagnetic interference. â "ANWZ" is the value for the time that the transponder remains in the field before the MDS STATUS command (mode 02) is executed. A time step is 10 ms. The maximum time that can be recorded is therefore 2.5 s. MDS STATUS for ISO mode (mode 03) corresponds to UDT 230 Table 9- 3 MDS STATUS for ISO mode Name Type UID array[1âŚ8] byte Possible values Unique identifier 000000000 0000000 hex to FFFFFFFF FFFFFFFF hex MDS_type Comment =8 byte UID, MSB first Tag type (vendor, identification) byte 01 hex 03 hex 04 hex 05 hex 06 hex 07 hex = ISO general (non-specific or unknown) = my-d (Infineon) = MB89R118 (Fujitsu) = I-Code SLI (NXP) = Tag-it HFI (Texas Instruments) = LRI2K (ST) IC_version byte 0 to FF hex Chip version size byte 0 to FF hex Memory size in bytes Depending on tag type, e.g. my-d: 992 bytes 252 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 System diagnostics 9.2 Diagnostics functions Name Type Possible values Comment lock_state byte 0 to FF hex Lock status, OTP information: one bit is used per block (4 x 4 bytes or 2 x 8 bytes) (bit = 1: block is locked) e.g. 01 = Block 1 of address FF80 - FF83 is locked or 03 = Block 1 and 2 of address FF80 - FF87 are locked, e.g. for the Philips SL2 ICS20 (MDS D124, D160 or D100). This chip provides a usable memory (112 bytes EEPROM) from address 0000 - 006F (total OTP area 0060 - 006F). In this memory, the locked area corresponds to the addresses 0060 - 0063 or 0060 - 0067 block_size byte 0 to FF hex nr_of_blocks byte 0 to FF hex Block size of the transponder Depending on tag type, e.g. my-d: 4 bytes Number of blocks Depending on tag type, e.g. my-d: 248 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 253 A Appendix A.1 Certificates and approvals Certificate Description CE Approval to R&TTE Notes on CE marking The following applies to the system described in this documentation: The CE marking on a device is indicative of the corresponding approval: DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems). EQ-Net certificate no.: 1323-01 Certifications for the United States, Canada, and Australia Safety One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) per UL 60950 (I.T.E) or per UL 508 (IND.CONT.EQ) Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950 (I.T.E) or C22.2 No. 142 (IND.CONT.EQ) Underwriters Laboratories (UL) according to standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142 (IND.CONT.EQ) UL recognition mark SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 255 Appendix A.1 Certificates and approvals One of the following markings on a device is indicative of the corresponding approval: Canadian Standard Association (CSA) per Standard C22.2. No. 60950 (LR 81690) or per C22.2 No. 142 (LR 63533) Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533) EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations. Modifications Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Conditions of Operations This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CANADA Canadian Notice This Class A digital apparatus complies with Canadian ICES-003. AUSTRALIA This product meets the requirements of the AS/NZS 3548 Norm. 256 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.2 Accessories A.2 Accessories CD "RFID Systems Software & Documentation" The CD contains: â FB/FC for SIMATIC, 3964R â Driver for DOS/Windows 95/NT/2000/XP â C libraries â PC demonstration program â RFID documentation in PDF format, especially RFID system manuals, programming instructions and operating instructions The "RFID Systems Software & Documentation" CD has a user-friendly interface based on HTML. After Start.exe has been called, a window for selecting the RFID system appears: â RF300 â RF600 â RF-MANAGER â MOBY â CM/ASM After selecting the RFID system, you can navigate to the required information. Product Order number CD "RFID Systems Software & Documentation" 6GT2 080-2AA10 Note Notes on "RFID system software" and licensing When purchasing a communication module or an interface module, no software or documentation is supplied. The "RFID Systems Software & Documentation" CD-ROM contains all available FBs/FCs for the SIMATIC, C libraries, demo programs, etc. and needs to be ordered separately. In addition, the CD-ROM contains the complete RFID documentation (German, English and French) in PDF format. The purchase of a communication module or an interface module includes a payment for the use of the software, including documentation, on the "RFID Systems Software & Documentation" CD-ROM and the purchaser acquires the right to make copies (copy license) insofar as they are required as part of the customer-specific application or development for the plant. The enclosed contract pertaining to the use of software products against a one-off payment shall apply in addition. SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 257 Appendix A.3 Connecting cable A.3 Connecting cable In the following chapter, you will find an overview of the connecting cables between the readers and communication modules or PCs. A.3.1 Reader RF3xxR (RS422) with ASM 452/ASM 473 A reader always occupies two M12 connection sockets on the ASM 452/ASM 473 A pre-assembled cable therefore ensures easy connection of the reader (see figure below). The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables. $60VLGH 5HDGHUVLGH ; ; ; ; ; ; ; 7ZRSLQ0 ; FLUFXODUFRQQHFWRUV ; ; Figure A-1 A.3.2 JUHHQ ZKLWH EURZQ \HOORZ SLQN JUD\ VKLHOG 0SLQ Connecting cable between ASM 452/473 and RF3xxR reader with RS422 (6GT28911CH20) Reader RF3xxR (RS422) with ASM 456/RF170C/RF180C $60VLGH 0FRQQHFWRU PDOH 5HDGHUVLGH Figure A-2 258 Connecting cable between ASM 456, RF170C, RF180C and reader RF3xxR (RS422) SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.3 Connecting cable A.3.3 Table A- 1 Ordering data Length L Order number 2m 6GT2891-0FH20 5m 6GT2891-0FH50 10 m 6GT2891-0FN10 20 m 6GT2891-0FN20 50 m 6GT2891-0FN50 Reader RF3xxR (RS422) with ASM 475 Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-0F plug-in cables. $60VLGH 5HDGHUVLGH &DEOHZLWKHQGVOHHYHV JUD\ SLQN \HOORZ EURZQ ZKLWH JUHHQ VKLHOG 6/*FRQQHFWRU 6RFNHW 0SLQ &DEOHVKLHOGH[SRVHG *7(ZLWKVWUDLJKW6/*FRQQHFWRU VWDQGDUG Figure A-3 Installation of connecting cable between ASM 475 and RF300 reader with RS 422 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 259 Appendix A.3 Connecting cable A.3.4 RF310R and IQ-Sense The connecting cable is available in lengths of 5 m (standard) and 10 m. 5HDGHU6HLWH ,46HQVH6HLWH EUDXQ 6/*6WHFNHU 0%XFKVH EODX Figure A-4 A.3.5 Configuration of connecting cable from 8xIQ-Sense to RF310R Length Order number 5m 3RX8000-0CB42-1AF0 10 m 3RX8000-0CB42-1AL0 Reader RF380R (RS232) - PC The connecting cable (6GT2891-0KH50) is 5 m long. Special feature of the cable: additional branch for the power supply. 68%'SLQ 3& 6RFNHW SROH 0 SLQ 5HDGHUVLGH Figure A-5 Connecting cable RF380R (RS232) to the PC Suitable power supply unit: e.g. wide-range power supply unit 260 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.4 Ordering data Table A- 2 Ordering data for wide-range power supply unit Wide-range power supply unit for SIMATIC RF-systems (100 - 240 V AC / 24 V DC / 3 A) with 2 m connecting cable with country-specific plug A.4 EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 Ordering data RF300 components Table A- 3 RF300 reader Readers Description RF310R (IQ-Sense) ďˇ ďˇ ďˇ ďˇ ďˇ With IQ-Sense interface IP 67 Operating temperature: -25 °C to +70 °C Dimensions: 55 x 75 x 30 (L x W x H, in mm) with integrated antenna 6GT2801-0AA00 RF310R (RS422) ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ With RS422 interface (3964R) IP 67 Operating temperature: -25 °C to +70 °C Dimensions: 55 x 75 x 30 (L x W x H, in mm) with integrated antenna ISO 15693 compatible 6GT2801-1AB10 RF340R ďˇ ďˇ ďˇ ďˇ ďˇ With RS422 interface (3964R) IP 67 Operating temperature -25 °C ⌠+70 °C Dimensions 75 x 91 x 41 (L x W x H in mm) with integrated antenna 6GT2801-2AB10 RF350R ďˇ ďˇ ďˇ ďˇ ďˇ With RS422 interface (3964R) IP 65 Operating temperature: -25 °C ⌠+70 °C Dimensions: 75 x 96 x 41 (L x W x H, in mm) For pluggable antennas ANT 1, ANT 12, ANT 18, ANT 30 6GT2801-4AB10 RF380R ďˇ ďˇ ďˇ ďˇ ďˇ ďˇ With RS422 interface (3964R) IP 67 Operating temperature: -25 °C ⌠+70 °C Dimensions: 160 x 96 x 40 (L x W x H, in mm) with integrated antenna ISO 15693 compatible 6GT2801-3AB10 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Order number 261 Appendix A.4 Ordering data Table A- 4 Antennae Antenna Description ANT 1 ďˇ ďˇ ďˇ IP67 Operating temperature: -25 °C to +70 °C Dimensions: 75 x 75 x 20 (L x W x H, in mm) 6GT2398-1CB00 ANT 12 ďˇ ďˇ ďˇ IP67 Operating temperature: -25 °C to +70 °C Dimensions: M18 x 1.0 x 55 6GT2 398-1CC00 ANT 18 ďˇ ďˇ ďˇ IP67 (front) Operating temperature -25 °C to +70 °C Dimensions: M18 x 50 (Ă x L in mm) 6GT2398-1CA00 ANT 30 ďˇ ďˇ ďˇ IP67 (front) Operating temperature -25 °C to +70 °C Dimensions: M30 x 58 (Ă x L in mm) 6GT2398-1CD00 Table A- 5 Order number RF300 transponder RF300 transponder Description Order number RF320T ďˇ ďˇ ďˇ ďˇ IP67 Memory size: 20 byte EEPROM Operating temperature: -25 °C to +85 °C Dimensions: 27 mm x 4 mm (Ă x H in mm) 6GT2800-1CA00 RF340T ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 8 KB FRAM Operating temperature: -25 °C to +85 °C Dimensions: 48 x 25 x 15 (L x W x H, in mm) 6GT2800-4BB00 RF350T ďˇ ďˇ 6GT2800-5BD00 ďˇ ďˇ IP68 Memory size: 32 KB FRAM (read/write) and 4 byte EEPROM (read only) Operating temperature: -25 °C ⌠+85 °C Dimensions: 50 x 50 x 20 (L x W x H, in mm) RF360T ďˇ ďˇ ďˇ ďˇ IP67 6GT2800-4AC00 Memory size: 8 KB FRAM (read/write) and 4 byte EEPROM (read only) Operating temperature: -25 °C ⌠+75 °C Dimensions: 85.8 x 54.8 x 2.5 (L x W x H, in mm) RF370T (32 KB FRAM) ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 32 KB FRAM Operating temperature: -25 to +85 °C Dimensions: 75 x 75 x 40 (L x W x H, in mm) 262 6GT2800-5BE00 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.4 Ordering data RF300 transponder Description Order number RF370T (64 KB FRAM) ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 64 KB FRAM Operating temperature: -25 °C to +85 °C Dimensions: 75 x 75 x 40 (L x W x H, in mm) 6GT2800-6BE00 RF380T ďˇ ďˇ ďˇ ďˇ IP68 Memory size 32 KB FRAM (read/write) and 4 byte EEPROM Operating temperature -25 ⌠+200 °C (cyclic) Dimensions: 114 x 83 (Ă x H in mm) 6GT2800-5DA00 Table A- 6 ISO transponder ISO transponder Description MDS D100 ďˇ ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 112 byte EEPROM Operating temperature: -25 ⌠+80 °C Dimensions: 85.6 x 54 x 0.9 (L x W x H, in mm) ISO card 6GT2600-0AD10 MDS D124 ďˇ ďˇ ďˇ ďˇ IP67 Memory size: 112 byte EEPROM user memory Operating temperature: -25 ⌠+125 °C Dimensions: 27 mm x 4 mm (Ă x H in mm) 6GT2600-0AC00 MDS D139 ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 112-byte user memory Operating temperature: up to +200 °C/+220 °C [heat-resistant (r/w)] Dimensions: 85 x 15 (Ă x H in mm) 6GT2600-0AA10 MDS D160 ďˇ ďˇ ďˇ ďˇ ďˇ IP68 (24 hours, 2 m, +20 °C) Memory size: 112 byte user memory Operating temperature: -25 °C...+70 °C Dimensions: 16 x 3 Âą0.1 (Ă x H in mm) Laundry tag for cyclical applications (r/w) 6GT2600-0AB10 MDS D324 ďˇ ďˇ ďˇ ďˇ IP67 Memory size: 992 byte EEPROM user memory Operating temperature: -25 °C...+125 °C Dimensions: 27 x 4 (Ă x H in mm) 6GT2600-3AC00 MDS D421 ďˇ ďˇ ďˇ ďˇ IP67/x9K Memory size: 2000 byte user memory Operating temperature: â25 °C to +85 °C Dimensions: 10 x 4.5 (Ă x H in mm) 6GT2600-4AE00 MDS D424 ďˇ ďˇ ďˇ ďˇ IP67 Memory size: 992 byte EEPROM user memory Operating temperature: -25 °C ...+125 °C Dimensions: 27 x 4 (Ă x H in mm) 6GT2600-4AC00 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Order number 263 Appendix A.4 Ordering data ISO transponder Description MDS D428 ďˇ ďˇ ďˇ ďˇ IP68; IP x9K Memory size: 2000 byte FRAM user memory Operating temperature: -25 °C ...+85 °C Dimensions (D x H): 18 mm x 20 mm (without thread), tolerance 1 mm; M8 thread 6GT2600-4AK00 MDS D460 ďˇ ďˇ ďˇ ďˇ IP68 Memory size: 2000 byte FRAM user memory Operating temperature: -25 °C ...+85 °C Dimensions: 16 x 3 Âą0.1 (Ă x H in mm) 6GT2600-4AB00 Table A- 7 Order number Communication modules/interface modules ASM/ communication module Description Order number ASM 452 ďˇ ďˇ ďˇ for PROFIBUS DP-V1, 1x RF3xxR with RS422 interface without connector for 24 V DC and PROFIBUS 6GT2002-0EB20 ASM 456 ďˇ ďˇ for PROFIBUS DP-V1 For connecting as many as 2 readers 6GT2002-0ED00 ASM 473 1x RF3xxR reader with RS422 can be connected ASM 475 ďˇ ďˇ RF170C Communication module, 1 unit 6GT2002-0HD00 Connection module, 1 unit 6GT2002-1HD00 RF180C communication module max. 2 SLGs or readers can be connected 6GT2002-0JD00 RF180C RF182C For SIMATIC S7 2 x readers RF3xxR with RS422 can be connected in parallel without a front connector 6GT2002-0HA10 6GT2002-0GA10 Connection block M12, 7/8" PN 6GT2002-1JD00 Push-pull connection block, RJ45 6GT2002-2JD00 RF182C communication module 6GT2002-0JD10 Max. 2 SLGs or readers can be connected 8xIQ-Sense Connection block M12, 7/8'' (5-pole) 6GT2002-1JD00 Connection block M12, 7/8'' (4-pole) 6GT2002-4JD00 Push-pull connection block, RJ45 6GT2002-2JD00 â IQ-Sense SM338 for S7-300 and ET200M for the connection of up to 8xIQ-Sense sensors 6ES7 3387XF000AB0 â Optical sensors, ultrasonic sensors and RF identification systems can be connected. 264 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.4 Ordering data Accessories Table A- 8 Accessories for RF300 reader Readers Accessories Order number RF380R Connecting cable RS232 to PC 6GT2891-0KH50 Table A- 9 Accessories for RF300 tags Tag Accessories Order number RF360T Spacers 6GT2190-0AA00 Fixing pocket 6GT2190-0AB00 Holder (short version) 6GT2090-0QA00 Holder (long version) 6GT2090-0QA00-0AX3 Covering hood 6GT2090-0QB00 Universal holder 6GT2590-0QA00 RF380T Table A- 10 Accessories for ISO tags MDS Accessories MDS D100 Spacers 6GT2190-0AA00 Fixing pocket 6GT2190-0AB00 Fixing pocket (cannot be mounted directly on metal) 6GT2390-0AA00 Spacer [85 mm x 30 mm (Ă x H in mm)] 6GT2690-0AA00 MDS D139 Table A- 11 Order number Connecting cable accessory - ASM/communication module to reader ASM - Reader Description Order number ASM 452/ Length ASM 473 2m 6GT2891-1CH20 and reader RF3xxR with RS422 5m 6GT2891-1CH50 ASM 456/RF170C/ Length RF180C 2m 6GT2891-0FH20 5m 6GT2891-0FH50 10 m 6GT2891-0FN10 20 m 6GT2891-0FN20 50 m 6GT2891-0FN50 and reader RF3xxR (RS422) ASM 475 Length and reader 2m SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 6GT2891-0EH20 265 Appendix A.5 Service & Support ASM - Reader Description RF3xxR 5m (RS422) 8xIQ-Sense and RF310R Table A- 12 Order number 6GT2891-0EH50 Length 5m 3RX8000-0CB42-1AF0 10 m 3RX8000-0CB42-1AL0 RFID accessories, general RFID accessories, general Order number CD "RFID Systems Software & Documentation" 6GT2 080-2AA10 Wide-range power supply unit for SIMATIC RF systems EU: 6GT2898 0AA00 (100 - 240 V AC/24 V DC/3 A) UK: 6GT2898 0AA10 with 2 m plug-in cable with country-specific connector US: 6GT2898 0AA20 A.5 Service & Support Contact partner If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office. The addresses are found on the following pages: â On the Internet (www.siemens.com/automation/partner) â In Catalog CA 01 â In Catalog FS 10 specially for factory automation sensors Technical Support You can access technical support for all IA/DT projects via the following: â Phone: + 49 (0) 180 5050 222 (⏠0.14 /min. from the German landline network, deviating mobile communications prices are possible) â E-mail (mailto:support.automation@siemens.com) â Internet: Online support request form: (www.siemens.com/automation/support-request) Service & support for industrial automation and drive technologies You can find various services on the Support homepage (www.siemens.com/automation/service&support) of IA/DT on the Internet. There you will find the following information, for example: 266 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Appendix A.5 Service & Support â Our newsletter containing up-to-date information on your products. â Relevant documentation for your application, which you can access via the search function in "Product Support". â A forum for global information exchange by users and specialists. â Your local contact for IA/DT on site. â Information about on-site service, repairs, and spare parts. Much more can be found under "Our service offer". RFID homepage For general information about our identification systems, visit RFID homepage (www.siemens.com/simatic-sensors/rf). Technical documentation on the Internet A guide to the technical documentation for the various products and systems is available on the Internet: SIMATIC Guide manuals (www.siemens.com/simatic-tech-doku-portal) Online catalog and ordering system The online catalog and the online ordering system can also be found on the A&D Mall homepage. (www.siemens.com/automation/mall) Training center We offer appropriate courses to get you started. Please contact your local training center or the central training center in D-90327 Nuremberg. Phone: +49 (0) 180 523 56 11 (⏠0.14 /min. from the German landline network, deviating mobile communications prices are possible) For information about courses, see the SITRAIN homepage (www.sitrain.com). SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 267 Glossary SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 269 Index 8xIQ-Sense module Addressing, 244 Indicators, 241 Ordering data, 241 Cabinet configuration, 92 Cable, 258 Reader - ASM, 258 Shielding, 96 Calculation example, 39 Certificates, 255 Chemical resistance of the MDS MDS D139, 83 MDS D160, 86 Combinations Reader-tag, 18 Communication modules, 17, 209 Communication time Calculating, 37 Connecting cable Reader-communication module/ASM/PC, 258 Contact partner, 266 Conventions, 12, 20 Coupling paths, 91 Courses, 267 Customer benefits, 21 Antennae Minimum clearances, 121 Application Planning SIMATIC RF300, 27 Approvals, 255 ASM 452 Configuration, 214 Indicators, 213 Operating mode, 215 Ordering data, 212 Pin assignments, 213 PROFIBUS address and terminating resistor, 217 PROFIBUS configuration, 214 Reader connection system, 215 ASM 473 Design and function, 221 Dimensions, 228 Features, 221 Hardware configuration, 226 Maximum configuration of an ET 200X, 226 Notes on operation, 224 Ordering data, 222 Pin assignments, 223 Reader connection system, 226 Technical specifications, 227 ASM 475 Assignment for connecting cable, 234, 259 Cable installation, 235 Design and function, 229 Function of the LEDs, 231 Indicators, 231 Ordering data, 230 Pin assignment, 234, 259 Status display with LEDs, 232 Data transmission rate MDS D100, 55 MDS D124, 56 MDS D139, 57 MDS D160, 58 MDS D324, 59, 60, 61, 62 RF320T, 49 RF340T, 50 RF350T, 51 RF360T, 52 RF370T, 53 RF380T, 54 Design System Manual, 11 Detection area, 35 Diagnostic functions Transponder, 251 Direction of motion Transponder, 35 Display elements SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 271 Index RF310R reader with IQ-Sense interface, 101 RF310R reader with RS422 interface, 105, 110, 115, 126 RF340R reader, 110 Dwell time Transponder, 36 Dynamic mode, 36 Dwell time of the transponder, 36 Several readers, 64 Installation guidelines, 62 Interface modules, 209 Interference sources Electromagnetic, 90 IQ-Sense interface Pin assignment, 100, 243 ISO functionality, 99 Electromagnetic compatibility Coupling paths, 91 Electromagnetic interference, 89 EMC Directives Propagation of electromagnetic interference, 89 EMC Guidelines, 256 Avoiding interference, 94 Basic Rules, 88 Cabinet configuration, 92 Cable shielding, 97 Definition, 87 Equipotential bonding, 95 Overview, 86 Equipotential bonding, 95 Error codes Readers, 247 LEDs For MOBY, 223 for PROFIBUS DP, 223 Low-performance, 16 FC 45, 248 Features of ASM 452 interface module Area of application, 211 Field data RF310R reader, 44 Fields of application, 20 Fixing pocket for MDS D100, 174 Flush-mounting of transponders and readers, 64 High-performance, 16 Inductive alternating field, 27 Input parameter, 209 Installation 272 Main applications, 20 MDS STATUS, 248 Medium-performance, 16 Memory configuration of the RF300 tags, 134 Metal Influence on the transmission window, 66 Metal-free area Reader RF310R, 101, 106 Reader RF340R, 110, 127 Transponder RF320T, 136 Transponder RF340T, 140 Transponder RF350T, 143 Transponder RF360T, 147 Transponder RF370T, 152 Transponder RF380T, 159 Minimum clearances Antenna to antenna, 121 Minimum distance Antenna to antenna, 48 Reader to reader, 48 Transponder to transponder, 47 Ordering data, 261 8xIQ-Sense module, 241 Antennae, 262 Interface modules/communication Modules, 264 Overview, 261 Readers, 261 RF300 transponder, 262 RF310R with IQ-Sense, 100 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 Index Parameterization Function blocks, 209 PROFIBUS cable Stripped lengths, 228 Read/write distance, 27 Reader RF310R Display elements, 101 Metal-free area, 101, 106 Pin assignment of IQ-Sense interface, 100 Reader RF340R Metal-free area, 110, 127 Readers, 99 Mounting, 64 Reducing interference due to metal, 63 Reduction of field data by metal RF340R, 68, 69 RF350R with ANT 1, 70, 71, 72 RF350R with ANT 18, 72, 73 RF350R with ANT 30, 74 RF380R, 67, 75, 76 Resistance to chemicals Transponder, 77 RF310R reader, 100, 104, 113, 125 Characteristics, 100, 104, 113, 125 Minimum distance, 102, 106 Pin assignment of IQ-Sense interface, 243 RF340R reader, 109 Characteristics, 109 RF370T transponder/32 KB FRAM Technical specifications, 154 RFID systems Overview, 15 Selection criteria SIMATIC RF300 components, 27 Shielding, 97 SIMATIC RF300 Diagnostic functions, 248 SLG STATUS, 248 Spacers, 175 Static mode, 35 Dwell time of the transponder, 36 System diagnostics MDS status, 251 Overview, 248 System overview RFID systems, 15 Technical documentation On the Internet, 267 Technical specifications RF370T transponder/32 KB FRAM, 154 Transponder RF320T, 138 Transponder RF340T, 141 Transponder RF350T, 144, 150 Transponder RF360T, 150 Technical Support, 266 Time constants, 38, 39 Tolerance of pallet side transport, 40 Tolerance of pallet transport height, 39 Tracking Tolerance, 32 Tracking tolerances, 32 Training, 267 Transmission gaps, 41 Transmission window ANT18 and ANT30 (RF350R), 30 Impact of metal, 66 RF310R reader and ANT1 (RF350R), 28 RF340R reader, 29 RF380R reader, 31 Width, 32 Transponder Detection area, 35 Directions of motion, 35 Dwell time, 36 Mounting on metal, 65 Resistance to chemicals, 77 Transponder RF320T Characteristics, 136 Metal-free area, 136 Technical specifications, 138 Transponder RF340T Characteristics, 139 Metal-free area, 140 Technical specifications, 141 Transponder RF350T Characteristics, 142 Metal-free area, 143 Technical specifications, 144 Transponder RF360T Characteristics, 147 Metal-free area, 147 Technical specifications, 150 Transponder RF370T SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04 273 Index Characteristics, 151 Metal-free area, 152 Transponder RF380T Metal-free area, 159 User data Calculate maximum number, 37 Calculating, 37 274 SIMATIC RF300 System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 69 Page Layout : OneColumn Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0038ff43-431a-4979-bba8-868f63683a89 Producer : Acrobat Distiller 9.0.0 (Windows) Keywords : Company : SIEMENS AG Comments : Edition : 11/2009 - Zwischenstand 17.09.2009 System : SIMATIC Sensors Print-year : Document-class : System Manual Product-group : RFID systems Order-nr : A5E01642529-04 Ident-nr : Create Date : 2009:11:04 14:14:55+01:00 Creator Tool : Acrobat PDFMaker 9.1 für Word Modify Date : 2009:11:05 11:13:23+01:00 Metadata Date : 2009:11:05 11:13:23+01:00 Document ID : uuid:657bdabf-ff28-4a91-aff2-12a344e8a0da Instance ID : uuid:f252b023-9cd6-4193-a2e4-8bad4184b436 Format : application/pdf Creator : SIEMENS AG Title : SIMATIC RF300 Description : Author : SIEMENS AG Subject :EXIF Metadata provided by EXIF.tools