Siemens VAS5051B Car Diagnostic System with Bluetooth User Manual 219 GB A01 3 VAS 5051B UL Abnahme
Siemens AG Car Diagnostic System with Bluetooth 219 GB A01 3 VAS 5051B UL Abnahme
Siemens >
VAS5051B User manual
Vehicle Diagnostic, Testing and Information System VAS 5051B Operating manual A01.4 Ausgabestand: 06.08.04 IBR 219 08/04 IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B Safety Instructions Meaning of symbols The safety instructions in the Operating Manual, the Startup/Unpacking Instructions or in other documentation provided, on screen displays on the tester during operation and on the products themselves use symbols with the following meanings: Warning! Text with this symbol contains information for your safety and how you can reduce the risk of severe or fatal injury. The WARNING symbol warrants particular attention for your safety. Caution! Text with this symbol contains information about how you can avoid damage to the vehicle and the tester. The Caution symbol tells you that if the information is ignored, damage to the vehicle and/or the tester could result (e.g.: Ensure that the touchscreen is not touched with sharp, edged objects). Note Text with this symbol contains additional, useful information. A Note symbol contains other, special instructions for using the device, and related information. Note The general safety instructions are listed in the following. Further instructions are to be found in the Operating Manual. Therefore read the Operating Manual before use. Safety instructions may also appear on the screen of the tester. Follow all the instructions displayed. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B IMPORTANT SAFETY INSTRUCTIONS 1. Warning! Read all instructions. 2. Warning! Do not operate equipment with a damaged cord or if the equipment has been damaged - until it has been examined by a qualified serviceman. 3. Warning! Do not let cord hang over edge of table, bench or counter, or come in contact with hot manifolds or moving fan blades. 4. Warning! An extension cord is not allowed. For testing use only specified cables. 5. Warning! Always unplug equipment from electrical outlet when not in use. Never yank cord to pull plug from outlet. Grasp plug and pull to disconnect. 6. Warning! To protect against risk of fire, do not operate equipment in the vicinity of open containers of fuel (gasoline). Risk of explosion This equipment has internal arcing or sparking parts wich should not be exposed to flammable vapour. This equipment should be located at least 460 mm (18 inches) above the floor. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. ii IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 7. Warning! Adequate ventilation should be provided when working on operating combustion engines. 8. Warning! Use only as described in this manual. Use only manufactures’s recommended attachments. 9. Warning! When connected to electrical power supply, the devices correspond to protection class 1 and are fitted with a safety-tested power cable. They may only be connected to electrical networks with an earthed protective conductor (TN networks) or electrical outlets with earthed protective conductors. 10. Warning! All measurement probes shall be used within their specifications and as described within these instructions. All measurement clamps shall be used on appropriate insulated wiring. Do not conduct measurement, if the wiring is damaged. 11. Warning! During test drives, secure the tester with a strap on the vehicle's back seatand connect it to the vehicle using the diagnostic cable. A second person must operate the tester from the back seat. Operation from the front seat is too dangerous, e.g. in the event of airbag activation. VAS 5051 To supply the VAS 5051 with power from the vehicle battery, use only the 3 m diagnostic cable. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. iii IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 12. Warning! Electrical ignition systems carry currents of up to approx. 30 kV. Observe general safety guidelines for workshops at all times. 13. Warning! If you open the tester or its accessories without authorisation or carry out improper alterations to them, considerable risk to you and to the device may result. 14. Caution! Fluctuations and deviations in the power supply beyond the permitted range of tolerance can lead to malfunctions and damage. 15. Caution! VAS 5051 - changing fuse For inline current measurement with the VAS 5051, only a replacement fuse of the same type and same amperage may be installed in order to avoid risks of fire and to protect the device. To order original parts, refer to the corresponding chapters of the Operating Manual. 16. Caution! when connecting other vehicle makes The VAS 505x diagnostic devices were developed for vehicles from the Volkswagen group. If the tester is connected directly to vehicles from other manufacturers, damage to the vehicle could result. Therefore if vehicles of other makes are to be tested using the general OBD functions in the self-diagnosis application, the OBD adapter cable VAS 5052/16 needs to be connected between the diagnostic cable and the diagnostic connection on the vehicle (with fewer cable connections). 17. Caution! • • • • Battery change may only be performed by qualified personel. Do not short out the battery. Do not incinerate the battery. Dispose/recycle the battery in accordance with local environmental regulations. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. iv IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B Warnings because of built-in Bluetooth transceiver 18. Warning! FCC 15.105: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 19. Warning! FCC 15.19: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1. this device my not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. 20. Warning! FCC 15.21: Changes or modifications made to this equipment not expressly approved by COMPANY may void the FCC authorization to operate this equipment. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 21. Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. SAVE THESE INSTRUCTIONS Trade Name: Siemens AG Model No: VAS 5051B FCC ID: LYHVAS5051B IC: 267AA-VAS5051B This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note A Bluetooth interface application for communication with external devices, e. g. diagnostic head VAS 5054 is projected. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. vi Technical Data VAS 5051B Technical Data 2.1 VAS 5051B Operating Unit (Tester) 2.1.1 Operating Data Dimensions (W x H x D) Approx. 410 x 310 x 95 mm Weight Approx. 7.6 kg Ambient conditions Operation Ambient temperature Relative humidity Transportation and storage Ambient temperature Relative humidity +5 to +40 °C by max. +25 °C 10 to 80 %, non-condensing -20 to +60 °C by max. +25 °C 10 to 80 %, non-condensing Electrical protection and safety Safety regulations - Workshop devices: UL 201 - Devices for information processing: DIN EN 60950 (VDE 0805), EN 60950, IEC 950, UL 1950, CSA-C22.2 No. 950 - Testing devices: DIN EN 61010-1 (VDE 0411 Part 1), EN 61010-1, IEC 1010-1 Protection class I (as per DIN EN 60950), relevant for the external adapter unit only Protected from water and foreign objects as per DIN VDE 0470 Part 1 (EN 60529, IEC 529) - Degree of protection: IP 20 For company-internal use only Pollution Degree II Overvoltage category I Power supply Power is supplied by one of the following, depending on the application: - Power adapter - Battery - Vehicle electrical system Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. 2-1 Technical Data VAS 5051B Power supply from power adapter Current consumption DC 24 V, 5 A Power supply from the battery If the external power supply (power adapter, mains power, vehicle electrical system) is interrupted, the tester is buffered with the battery. Li-ION, 14.8 V Battery type Buffer time Recharge time (on mains) Power supply from the vehicle electrical system Rated voltages Current consumption in the load range Protection Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// Usually 1 h (depending on operating mode, battery state and the external consumers) Approx. 2.5 h (only with adapter unit connected) The tester can be powered from the vehicle electrical system. DC 12 V, DC 24 V max. 5 A with 12 V battery voltage The input is protected against disturbance variables to DIN 40839 part 1, test pulses 1 to 4, test severity IV. The input is protected against polarity reversal. 08/04 All rights reserved. 2-2 Technical Data VAS 5051B External interfaces, wired COM1 (V.24) USB interface Monitor (VGA) Ethernet interface Audio input Audio output Power output Card reader PCMCIA slot DC input Socket panel (test instruments) DIAG URDI DSO1, DSO2 SZ KV TZ T/D External interfaces, wireless IrDA Bluetooth 2.2 9-pin Sub-D connector for RS232/RS485 4 x USB 2.0 standard 15-pin Sub-HD socket RJ45 socket Jack bush 3.5 mm Jack bush 3.5 mm, At 8 W load: 200 mW (at 0.1 % distortion) At 32 W load: 85 mW (at 0.1 % distortion) Smartcard as per ISO 7816 For PCMCIA cards 1 x type III or 2 x type II 2-pin mini SNAP socket, size 2. Mini SNAP sockets Diagnosis interface, 18-pin Multimeter, 14-pin, size 3 Storage oscilloscope, 12-pin, size 2 Current pick-up, 8-pin, size 2 Kilovolt pick-up, 5-pin, size 1 Trigger pick-up, 5-pin, size 1 Temperature/pressure, 10-pin, size 2 Infrared interface for printer Radio interface for extensions Power Adapter Power Adapter The power adapter supplies the VAS 5051B operating unit from the 230 (110) volt network. The power adapter is housed in the workshop trolley. Rated voltage range Rated frequencies AC 100 to 240 V 50 - 60 Hz DC cable The DC cable (approx. 1.2 m) is permanently connected to the power adapter. Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. 2-3 Technical Data VAS 5051B Mains cable (internal) Plug type Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// The mains cable (approx. 3 m) is connected to the mains network in the workshop trolley. Plug for non-heating apparatus type C13, EN60320/C13 Variant 1: Schuko plug, Type VII as per CEE(7) VII Variant 2: USA plug, Type 498 G as per NEMA 5-15 08/04 All rights reserved. 2-4 Technical Data VAS 5051B 2.3 Test Instruments 2.3.1 Multimeter Caution Maximum voltage of the U/R/D/I measuring lead: DC 50 V or 42 Vpeak Direct voltage at U/R/D/I (Ri ≥ 1 MΩ) Range -2 to +2 V Resolution 0.001 V -20 to +20 V 0.01 V -50 to +50 V 0.01 V Range Resolution Tolerance 0 to 2 V 0.001 V 0 to 20 V 0.01 V 0 to 40 V 0.01 V ±1.5 % of m. ±4 mV ±1.5 % of m. ±40 mV ±1.5 % of m. ±80 mV Range Resolution Tolerance 0 to 2 V 0.001 V 0 to 20 V 0.01 V 0 to 40 V 0.01 V ±5 % of m. ±4 mV ±5 % of m. ±40 mV ±5 % of m. ±80 mV Direct current inline (Ri ≤ 250 mΩ) via U/R/D/I measuring lead Range -0.2 to 0.2 A -2 to 2 A Resolution 0.0001 A 0.001 A Tolerance ±1 % of m. ±1 mA ±1 % of m. ±10 mA Alternating Current inline (effective value, 30 to 500 Hz, crest factor max. 3, Ri ≤ 250 mΩ) via U/R/D/I measuring lead Range 0 to 0.2 A 0 to 2 A Resolution 0.0001 A 0.001 A Tolerance ±1.5 % of m. ±1 mA ±1.5 % of m. ±10 mA Alternating voltage at U/R/D/I (effective value, 50 Hz to 5 kHz, crest factor max. 3, Ri ≥ 1 MΩ) Alternating voltage at U/R/D/I (effective value, 5 kHz to 10 kHz, crest factor max. 3, Ri ≥ 1 MΩ) Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 Tolerance ±0.5 % of m. ±2 mV ±0.5 % of m. ±20 mV ±0.5 % of m. ±50 mV All rights reserved. 2-5 Technical Data VAS 5051B Resistance via U/R/D/I measuring lead The measured current depends on the measurement range and is maximum 5 mA. Range Resolution Tolerance2) 0 Ω to 10 Ω 10 mΩ ±1 % of m. ±5 mΩ 0 Ω to 100 Ω 0.1 Ω ±1 % of m. ±50 mΩ 0 Ω to 1 kΩ 1Ω ±1 % of m. ±1 Ω 0 Ω to 10 kΩ 10 Ω ±1 % of m. ±10 Ω 0 Ω to 100 kΩ 100 Ω ±1.5 % of m. ±100 Ω 0 Ω to 1 MΩ 1 kΩ ±2 % of m. ±1 kΩ 0 Ω to 10 MΩ 10 kΩ ±2 % of m. ±10 kΩ An acoustic signal is heard at a test object resistance of < 2 Ω in continuity measurements in the range 10 Ω. 2) Accuracy in measurement range 10 Ω and 100 Ω is given only after zero balancing Diode test via U/R/D/I measuring lead Measurement current 1 mA Measurement voltage max. 5 V The current flow direction is indicated by a diode symbol. During the measurement the polarity of the measurement current is reversed. Direct current via current pick-up 100 A Range -5 to +5 A -50 to +50 A -100 to +100 A 1) Alternating current via current pick-up 100 A (effective value, 30 Hz to 1 kHz, crest factor max. 3) Direct current via current pick-up 1800 A Resolution 1 mA 10 mA 100 mA Tolerance ±3 % of m. ±15 mA1) ±3 % of m. ±25 mA1) ±3 % of m. ±200 mA1) The accuracy of the current pick-up is given only after calibration and without change of position and temperature. Range Resolution -900 to +900 A 0.1 A Tolerance ±3.5 % of m. ±1.5 A1) -1800 to +1800 A ±5.5 % of m. ±2 A1) ±3.5 % of m. ±2 A1) bis ±1500 A 1) Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// Tolerance ±2 % of m. ±10 mA1) ±2 % of m. ±20 mA1) ±2 % of m. ±200 mA1) The accuracy of the current pick-up is given only after calibration and without change of position and temperature. Range 0 to +5 A 0 to +50 A 0 to +100 A 1) Resolution 1 mA 10 mA 100 mA 1A The accuracy of the current pick-up is given only after calibration. 08/04 All rights reserved. 2-6 Technical Data VAS 5051B Alternating current via current pick-up 1800 A (effective value, 30 Hz to 500 Hz, crest factor max. 3) Range 0 to +900 A Resolution 0.1 A Tolerance ±5.5 % of m. ±2.5 A1) 0 to +1800 A 1A ±5.5 % of m. ±3 A1) ±3.5 % of m. ±2 A1) bis ±1500 A 1) The accuracy of the current pick-up is given only after calibration. Caution Maximum voltage on DSO measuring lead: 400 Vpeak or 400 V DC Direct voltage at DSO1 (Ri ≥ 4 MΩ) Range -1.6 to 1.6 V -4 to 4 V -16 to 16 V -40 to 40 V -160 to 160 V -400 to 400 V Resolution 0.001 V 0.001 V 0.01 V 0.01 V 0.1 V 0.1 V Tolerance ±1 % of m. ±4 mV ±1 % of m. ±8 mV ±1 % of m. ±20 mV ±1 % of m. ±40 mV ±1 % of m. ±200 mV ±1 % of m. ±400 mV Alternating voltage at DSO1 (effective value, 30 Hz to 5 kHz, crest factor max. 2, Ri ≥ 4 MΩ) Range 0 to 1.6 V 0 to 4 V 0 to 16 V 0 to 40 V 0 to 160 V 0 to 400 V Resolution 0.001 V 0.001 V 0.01 V 0.01 V 0.1 V 0.1 V Tolerance ±3.5 % of m. ±6 mV ±3.5 % of m. ±11 mV ±3.5 % of m. ±55 mV ±3.5 % of m. ±80 mV ±3.5 % of m. ±275 mV ±3.5 % of m. ±550 mV Alternating voltage at DSO (effective value, 5 kHz to 10 kHz, crest factor max. 2, Ri ≥ 4 MΩ) Range 0 to 1.6 V 0 to 4 V 0 to 16 V 0 to 40 V 0 to 160 V 0 to 400 V Resolution 0.001 V 0.001 V 0.01 V 0.01 V 0.1 V 0.1 V Tolerance ±4.5 % of m. ±6 mV ±4.5 % of m. ±11 mV ±4.5 % of m. ±55 mV ±4.5 % of m. ±80 mV ±4.5 % of m. ±275 mV ±4.5 % of m. ±550 mV Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. 2-7 Technical Data VAS 5051B 2.3.2 Temperature Sensor T/P measuring input 2.3.3 Pressure Sensor T/P measuring input 2.3.4 The measuring input is designed for connection of a temperature sensor with a PT100 measuring element. The measuring input is designed for connection of a pressure sensor with a 4 mA to 20 mA interface. Digital Storage Oscilloscope (DSO) Caution Maximum voltage on DSO measuring lead: 400 Vpeak or 400 V DC Measuring leads DSO1/DSO2 measuring leads kV pick-up Trigger pick-up Current pick-up 100 A, 1800 A Pressure or temperature sensor Measurement inputs DSO1, DSO2 Make sure that both measurement connections are adapted on each cable. Bandwidth 100 kHz (±3 dB) Resolution 10 Bit Accuracy DC to 10 kHz ±1 %; 100 kHz -3 dB Measurement range selection Manual or automatic in Auto Setup Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 All rights reserved. 2-8 Technical Data VAS 5051B Measurement ranges DSO1, DSO2 Differential inputs Range ±0.4 V ±1.6 V ±4 V ±16 V ±40 V ±160 V ±400 V Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 Voltage divider ≥ 4 MΩ, 25 pF against protective conductor potential y deflection 50 mV/DIV 200 mV/DIV 500 mV/DIV 2 V/DIV 5 V/DIV 20 V/DIV 50 V/DIV All rights reserved. 2-9 Technical Data VAS 5051B Measuring channels CH1, CH2 Sampling rate Input bandwidth (-3 dB) Sampled-data storage Coupling Measuring channels Measurement inputs max. 40 MHz in channel 1 mode 10 MHz (without sensor) Depth 64 k (meas.vals.)/ channel AC, DC, GND DSO1, DSO2, kV pick-up current pick-up 100 A, 1800 A Pressure or temperature sensor Time base 1.25 µs/DIV 2.5 µs/DIV 5 µs/DIV 10 µs/DIV 20 µs/DIV 50 µs/DIV 100 µs/DIV 200 µs/DIV 500 µs/DIV 1 ms/DIV 2 ms/DIV 5 ms/DIV 10 ms/DIV 20 ms/DIV 50 ms/DIV 100 ms/DIV 200 ms/DIV 500 ms/DIV 1 s/DIV 2 s/DIV 5 s/DIV 10 s/DIV 20 s/DIV 50 s/DIV 100 s/DIV 3) 4) Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// Sampling rate 40 MHz3) 20 MHz 10 MHz 5 MHz 2.5 MHz 1 MHz 500 kHz 250 kHz 100 kHz 50 kHz 25 kHz 10 kHz 5 kHz 2.5 kHz 1 kHz 500 Hz 250 Hz 100 Hz 50 Hz 25 Hz 10 Hz 5 Hz 2.5 Hz4) 1 Hz4) 0.5 Hz4) In channel 1 mode Only in Draw mode 08/04 All rights reserved. 2-10 Technical Data VAS 5051B Measurement range kV Range ±8 kV ±20 kV ±40 kV y deflection 1 kV/DIV 2.5 kV/DIV 5 kV/DIV Tolerance ±15 % of m. ±200 V ±15 % of m. ±400 V ±15 % of m. ±800 V The size of the measurement error depends on the ignition cable insulation and applies to use in vehicle systems with mechanical distributors. The kV input and the kV pick-up (ignition voltage adapter) form a capacitive voltage divider. The tester can be adapted to a stationary ignition distributor system by external connection of the ignition voltage adapter. Trigger pick-up input To record ignition timing on high-voltage cables (secondary ignition coil) Trigger functions Trigger channel Trigger coupling Trigger edge Trigger level Trigger delay Trigger mode Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 DSO1, DSO2, Trigger pick-up or kV pick-up AC, DC, HF, LF positive, negative Automatic or adjustable in 1 % measurement range increments Pre-trigger and posttrigger, adjustable in 10 % deflection increments Single, Normal, Auto, Auto Level, Auto Setup, Draw mode All rights reserved. 2-11 Technical Data VAS 5051B 2.4 Measuring Leads Diagnostic cable Diagnostic cable, optional Diagnostic adapter Diagnostic cable LT, optional 5m 3m 0.3 m (for testing old vehicles) 3m Cable bend diameter 10 x cable diameter Plug cycles > 1.000 2.5 Mains Cable on Workshop Trolley Mains cable Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// The mains cable (6 m) can be replaced with a mains cable of the type applicable in the country of use. The mains cable must comply with the standard for operating appliances on an earthed power supply network. (VDE 0805, EN 60950, IEC 950, UL 1950, CSA 22.2 No. 950) For operation in the USA and Canada, use a UL cable, an oil resistant cable or a CSA-approved mains power cable. 08/04 All rights reserved. 2-12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2004:08:06 12:22:28Z Create Date : 2004:08:06 12:21:28Z Page Count : 19 Creation Date : 2004:08:06 12:21:28Z Mod Date : 2004:08:06 12:22:28Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : Admin Metadata Date : 2004:08:06 12:22:28Z Creator : Admin Title : 219 - GB_-A01.3- VAS 5051B-UL-Abnahme.book Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools