Signify North America SNH200 Luminaire mounted Light Sensor with 2.4GHz radio User Manual PLt 17265QG EasySense SNH200 QIG indd

Philips Lighting North America Corporation Luminaire mounted Light Sensor with 2.4GHz radio PLt 17265QG EasySense SNH200 QIG indd

PLt-17265QG_EasySense SNH200 QIG

Download: Signify North America SNH200 Luminaire mounted Light Sensor with 2.4GHz radio User Manual PLt 17265QG EasySense SNH200 QIG indd
Mirror Download [FCC.gov]Signify North America SNH200 Luminaire mounted Light Sensor with 2.4GHz radio User Manual PLt 17265QG EasySense SNH200 QIG indd
Document ID3820991
Application ID93AJYUImfX+lSoR5h0yrbg==
Document DescriptionPLt-17265QG_EasySense SNH200 QIG
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize138.89kB (1736174 bits)
Date Submitted2018-04-18 00:00:00
Date Available2018-04-18 00:00:00
Creation Date2018-04-12 16:44:52
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-04-12 16:44:58
Document TitlePLt-17265QG_EasySense SNH200 QIG.indd
Document CreatorAdobe InDesign CC 13.0 (Macintosh)

Sensor part number
SNH200
EasySense Outboard-Mount
for High Bay
Order Code
Commercial Product Name
Wiring requirements
Connectors
EASYSENSE
Compatible LED drivers
Xitanium 150W 0.105-1.05A 44-157V 120-277V SR with AUX
XI150C105V157VSF1
Xitanium 150W 0.07-0.70A 78-235V 120-277V SR with AUX
XI150C070V235VSF1
Xitanium 95W 0.03-2.75A 27-54V 120-277V SR with AUX
XI095C275V054VSF1
Xitanium 95W 0.03-2.75A 27-54V 120-277V SR
XI095C275V054VPF1
Xitanium 75W 0.105-1.05A 32-79V 120-277V SR with AUX
XI075C105V079VSY1
Xitanium 75W 0.07-0.70A 43-118V 120-277V SR with AUX
XI075C070V118VSY1
Xitanium 75W 0.1-2.0A 27-54V 120-277V SR
XI075C200V054VPT1
Xitanium 40W 0.1-1.1A 27-54V 120-277V SR
XI040C110V054VPT1
Description
Driver Model Number
Specifications available at www.philips.com/xitaniumsr/na.
GROUND
LINE
NEUTRAL
(2) 18AWG wires, non-polarized
Overall length 60cm
Strip length 8mm
SRSR+
SR
SR
NC
XITANIUM SR
LED DRIVER
LED+
LED+
LEDLEDRSET2
SGND
NFC ANTENNA
Note: Above depicts connecting wires from sensor
to Xitanium SR drivers that include connectors. For
connection to Xitanium SR drivers that include leads,
use wirenuts
suitable for 18AWG solid wire.
Wire to wire connection
SNH200 includes 18AWG wires, 60cm in length with 8mm strip length. A wire to wire connection can be made with
connectors or wirenuts suitable for 18AWG solid wire.
The wire strip length in case of a wire to wire connection is connector dependent.
Wire to driver connection
A connection between the sensor and the driver should be made according to local practices. The SR input wires of the
EasySense for High Bay are not polarized for fixtures using one driver and one sensor, and therefore can be connected,
without taking care of polarity, to the SR output of the driver – SR+ and SR- terminals. It is recommended to keep wire
distance from sensor to driver less than 50 feet. Polarity must be maintained when connecting multiple drivers to one sensor.
The wire strip length in case of sensor to driver connection is ~8mm.
PLt-17265QG_EasySense SNH200 QIG
04/18
Document #: 4422-107-07551 sh460 2018-04-12
PLt-17265QG_EasySense SNH200 QIG
04/18
Document #: 4422-107-07551 sh460 2018-04-12
Philips Lighting Canada Ltd.
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
© 2018 Philips Lighting Holding B.V. All rights reserved.
Philips reserves the right to make changes in specifications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
philips.com/easysense
Philips Lighting North America Corporation
10275 W. Higgins Road, Rosemont IL 60018
Tel: 800-322-2086 Fax: 888-423-1882
Customer/Technical Service: 800-372-3331
OEM Support: 866-915-5886
Philips EasySense Outboard-Mount for High Bay
Quick Installation Guide
Outboard-Mount
for High Bay
EasySense
Sensors
Sensor Dimensions, mm [in]
Daylight Sensor
The light sensor measures the total amount of light in a circular field of ≈80% of the PIR detection area.
The following aspects should be observed during installation:
•
Minimum distance from the window ≥ 2.0'/0.6m.
•
Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car bonnet)
as this will lead to incorrect light regulation.
1 5.7 [ 5 8]
1 .5 [ 1 1 6]
86
30.1 [ 1 3 1 6]
+1
1 45 64 +-0
43.25 -0
63
Sensor distance
to window
Sensor height with
respect to window
Optional view shield (included). Refer to
design-in guide for details on coverage
patterns when using view shield.
40
Ø1
Ø
SNH200
Wall
+1
Ø 1 15 -0
21 .5
Window
40 [ 1 5 8]
60
+ 00
1 7 32
[4
Minimum distance versus mounting height
[ 1 /2"] Straight pipe thread
1 43.8 [ 521 32 ]
+ 10
15 -
Photosensor spatial response
30
+1
43 -0
1 .5
63 [ 21 2 ]
M20x1.5
+ 0.5
1 4 -0
As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and
sensor whereby H is the height from the bottom of the window to the ceiling.
1 8.5 [ 3 4 ]
60 [ 23 8]
Note: Restrictions only for daylight regulation. No restrictions for skylights.
Floor
Mounting in a Luminaire
Configuration via Mobile App
EasySense for High Bay is intended to be mounted to a standard ½" knockout available on the luminaire itself or a junction
box. A washer and locknut are included with the sensor for this purpose. An OEM can develop custom brackets to attach to
the top surface of the sensor in case the sensor needs to be mounted to a curved/non-flat surface. Mounting screws are
provided with the sensor for this purpose. These screws are matched to the thickness of the plastic sensor housing. In case
other screws are used, ensure that they do not protrude through the sensor plastics. Also make sure that the view of the
sensor is not blocked anywhere by the luminaire or the bracket to avoid loss of functionality.
Note: Use of IR requires a specific IR dongle from Philips to configure and group from floor level. Consult your Philips representative.
Occupancy Sensing Coverage Pattern
You must first register for Philips field apps to receive a username and password, then download Philips field apps from the
Google Play Store. Refer to www.philips.com/easysense for details, including applicable Android phones and user manuals.
Based on 16m mounting height
EasySense parameters can be configured via Philips field apps available for Android phones. Two options are available:
1.
EasySense NFC – This app allows configuring EasySense parameters only when you can physically access the sensor
with a smartphone.
2.
EasySense Industry IR – This app allows configuring EasySense paramters plus enables grouping to a wireless switch,
which can be done with an Android phone and a specific IR dongle from Philips.
FCC and IC Statement This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC)
license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Any changes or modifications not expressly approved by Philips could void the user’s authority to operate this
equipment. This product is intended for commercial use only.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Déclaration De Conformité À La Fcc/Ic Ce dispositif est conforme à la partie 15 des règles de la Federal Communications
Commission (FCC) des États-Unis et d’Industrie Canada (IC) exempts de licence RSS norme(s). Son fonctionnement est
assujetti aux deux conditions suivantes : (1) Ce dispositif ne doit pas provoquer de brouillage préjudiciable, et (2) il doit
accepter tout brouillage reçu, y compris le brouillage pouvant entraîner un mauvais fonctionnement. Tous les changements
ou modifications non expressément approuvés par Philips, sont susceptibles d’annuler le droit de l’utilisateur à se servir de
cet équipement. Ce produit est exclusivement destiné à un usage commercial.
Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36
Create Date                     : 2018:04:12 16:44:52-05:00
Metadata Date                   : 2018:04:12 16:44:58-05:00
Modify Date                     : 2018:04:12 16:44:58-05:00
Creator Tool                    : Adobe InDesign CC 13.0 (Macintosh)
Instance ID                     : uuid:b92af1c2-194d-ec4e-8d70-aab4fa751480
Original Document ID            : xmp.did:16eac79c-1ca8-4de0-905c-7a864c64a44e
Document ID                     : xmp.id:08d004f4-3b31-4394-aad4-3b76dedfda79
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:94df47d9-d854-451e-b984-2770ff7c9a04
Derived From Document ID        : xmp.did:e322ded8-8f0b-4da8-baf3-1bbfb8834a58
Derived From Original Document ID: xmp.did:16eac79c-1ca8-4de0-905c-7a864c64a44e
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Macintosh)
History Changed                 : /
History When                    : 2018:04:12 16:44:52-05:00
Format                          : application/pdf
Title                           : PLt-17265QG_EasySense SNH200 QIG.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Page Count                      : 2
Creator                         : Adobe InDesign CC 13.0 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AF2N-SNH200

Navigation menu