Signify North America SNH200 Luminaire mounted Light Sensor with 2.4GHz radio User Manual PLt 17265QG EasySense SNH200 QIG indd
Philips Lighting North America Corporation Luminaire mounted Light Sensor with 2.4GHz radio PLt 17265QG EasySense SNH200 QIG indd
PLt-17265QG_EasySense SNH200 QIG
Sensor part number SNH200 EasySense Outboard-Mount for High Bay Order Code Commercial Product Name Wiring requirements Connectors EASYSENSE Compatible LED drivers Xitanium 150W 0.105-1.05A 44-157V 120-277V SR with AUX XI150C105V157VSF1 Xitanium 150W 0.07-0.70A 78-235V 120-277V SR with AUX XI150C070V235VSF1 Xitanium 95W 0.03-2.75A 27-54V 120-277V SR with AUX XI095C275V054VSF1 Xitanium 95W 0.03-2.75A 27-54V 120-277V SR XI095C275V054VPF1 Xitanium 75W 0.105-1.05A 32-79V 120-277V SR with AUX XI075C105V079VSY1 Xitanium 75W 0.07-0.70A 43-118V 120-277V SR with AUX XI075C070V118VSY1 Xitanium 75W 0.1-2.0A 27-54V 120-277V SR XI075C200V054VPT1 Xitanium 40W 0.1-1.1A 27-54V 120-277V SR XI040C110V054VPT1 Description Driver Model Number Specifications available at www.philips.com/xitaniumsr/na. GROUND LINE NEUTRAL (2) 18AWG wires, non-polarized Overall length 60cm Strip length 8mm SRSR+ SR SR NC XITANIUM SR LED DRIVER LED+ LED+ LEDLEDRSET2 SGND NFC ANTENNA Note: Above depicts connecting wires from sensor to Xitanium SR drivers that include connectors. For connection to Xitanium SR drivers that include leads, use wirenuts suitable for 18AWG solid wire. Wire to wire connection SNH200 includes 18AWG wires, 60cm in length with 8mm strip length. A wire to wire connection can be made with connectors or wirenuts suitable for 18AWG solid wire. The wire strip length in case of a wire to wire connection is connector dependent. Wire to driver connection A connection between the sensor and the driver should be made according to local practices. The SR input wires of the EasySense for High Bay are not polarized for fixtures using one driver and one sensor, and therefore can be connected, without taking care of polarity, to the SR output of the driver – SR+ and SR- terminals. It is recommended to keep wire distance from sensor to driver less than 50 feet. Polarity must be maintained when connecting multiple drivers to one sensor. The wire strip length in case of sensor to driver connection is ~8mm. PLt-17265QG_EasySense SNH200 QIG 04/18 Document #: 4422-107-07551 sh460 2018-04-12 PLt-17265QG_EasySense SNH200 QIG 04/18 Document #: 4422-107-07551 sh460 2018-04-12 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 © 2018 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/easysense Philips Lighting North America Corporation 10275 W. Higgins Road, Rosemont IL 60018 Tel: 800-322-2086 Fax: 888-423-1882 Customer/Technical Service: 800-372-3331 OEM Support: 866-915-5886 Philips EasySense Outboard-Mount for High Bay Quick Installation Guide Outboard-Mount for High Bay EasySense Sensors Sensor Dimensions, mm [in] Daylight Sensor The light sensor measures the total amount of light in a circular field of ≈80% of the PIR detection area. The following aspects should be observed during installation: • Minimum distance from the window ≥ 2.0'/0.6m. • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car bonnet) as this will lead to incorrect light regulation. 1 5.7 [ 5 8] 1 .5 [ 1 1 6] 86 30.1 [ 1 3 1 6] +1 1 45 64 +-0 43.25 -0 63 Sensor distance to window Sensor height with respect to window Optional view shield (included). Refer to design-in guide for details on coverage patterns when using view shield. 40 Ø1 Ø SNH200 Wall +1 Ø 1 15 -0 21 .5 Window 40 [ 1 5 8] 60 + 00 1 7 32 [4 Minimum distance versus mounting height [ 1 /2"] Straight pipe thread 1 43.8 [ 521 32 ] + 10 15 - Photosensor spatial response 30 +1 43 -0 1 .5 63 [ 21 2 ] M20x1.5 + 0.5 1 4 -0 As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the ceiling. 1 8.5 [ 3 4 ] 60 [ 23 8] Note: Restrictions only for daylight regulation. No restrictions for skylights. Floor Mounting in a Luminaire Configuration via Mobile App EasySense for High Bay is intended to be mounted to a standard ½" knockout available on the luminaire itself or a junction box. A washer and locknut are included with the sensor for this purpose. An OEM can develop custom brackets to attach to the top surface of the sensor in case the sensor needs to be mounted to a curved/non-flat surface. Mounting screws are provided with the sensor for this purpose. These screws are matched to the thickness of the plastic sensor housing. In case other screws are used, ensure that they do not protrude through the sensor plastics. Also make sure that the view of the sensor is not blocked anywhere by the luminaire or the bracket to avoid loss of functionality. Note: Use of IR requires a specific IR dongle from Philips to configure and group from floor level. Consult your Philips representative. Occupancy Sensing Coverage Pattern You must first register for Philips field apps to receive a username and password, then download Philips field apps from the Google Play Store. Refer to www.philips.com/easysense for details, including applicable Android phones and user manuals. Based on 16m mounting height EasySense parameters can be configured via Philips field apps available for Android phones. Two options are available: 1. EasySense NFC – This app allows configuring EasySense parameters only when you can physically access the sensor with a smartphone. 2. EasySense Industry IR – This app allows configuring EasySense paramters plus enables grouping to a wireless switch, which can be done with an Android phone and a specific IR dongle from Philips. FCC and IC Statement This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC) license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by Philips could void the user’s authority to operate this equipment. This product is intended for commercial use only. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Déclaration De Conformité À La Fcc/Ic Ce dispositif est conforme à la partie 15 des règles de la Federal Communications Commission (FCC) des États-Unis et d’Industrie Canada (IC) exempts de licence RSS norme(s). Son fonctionnement est assujetti aux deux conditions suivantes : (1) Ce dispositif ne doit pas provoquer de brouillage préjudiciable, et (2) il doit accepter tout brouillage reçu, y compris le brouillage pouvant entraîner un mauvais fonctionnement. Tous les changements ou modifications non expressément approuvés par Philips, sont susceptibles d’annuler le droit de l’utilisateur à se servir de cet équipement. Ce produit est exclusivement destiné à un usage commercial. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36 Create Date : 2018:04:12 16:44:52-05:00 Metadata Date : 2018:04:12 16:44:58-05:00 Modify Date : 2018:04:12 16:44:58-05:00 Creator Tool : Adobe InDesign CC 13.0 (Macintosh) Instance ID : uuid:b92af1c2-194d-ec4e-8d70-aab4fa751480 Original Document ID : xmp.did:16eac79c-1ca8-4de0-905c-7a864c64a44e Document ID : xmp.id:08d004f4-3b31-4394-aad4-3b76dedfda79 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:94df47d9-d854-451e-b984-2770ff7c9a04 Derived From Document ID : xmp.did:e322ded8-8f0b-4da8-baf3-1bbfb8834a58 Derived From Original Document ID: xmp.did:16eac79c-1ca8-4de0-905c-7a864c64a44e Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.0 (Macintosh) History Changed : / History When : 2018:04:12 16:44:52-05:00 Format : application/pdf Title : PLt-17265QG_EasySense SNH200 QIG.indd Producer : Adobe PDF Library 15.0 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 2 Creator : Adobe InDesign CC 13.0 (Macintosh)EXIF Metadata provided by EXIF.tools