Simcom 2013072401 GSM/GPRS/BT Wireless Data Module User Manual
Shanghai Simcom Ltd. GSM/GPRS/BT Wireless Data Module
Simcom >
User Manual
SIM800H Document SIM800H User Manual Compliance Information FCC Compliance Statement: This device complies with Part 15 of the FCC Rules . Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This device must accept any interference received, including interference that may cause undesired operation. Product that is a radio transmitter is labeled with FCC ID. FCC Caution: (1)Exposure to Radio Frequency Radiation. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. (2) Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. (3) This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. (4) Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. (5) the modules FCC ID is not visible when installed in the host, or (6) if the host is marketed so that end users do not have straight forward commonly used methods for access to remove the module so that the FCC ID of the module is visible; then an additional permanent label referring to the enclosed module: Contains Transmitter Module FCC ID: UDV-2013072401 or Contains FCC ID: UDV-2013072401 must be used. 1. SIM800H Description 1.1. Summarize SIM800H designed by SIMCom is a quad band module which supports GSM/GPRS. The baseband circuit is based on MTK and RF circuit is based on RFMD. It works at quad bands------GSM850, EGSM900, DCS1800, and PCS1900. CPU clock is based on 26MHz crystal. The main IC includes MT6260D and RF7176. 1.2. Feature ƽ Quad-Band 850/900/1800/1900MHz ƽ GPRS multi-slot class 12/10 ƽ GPRS mobile station class B ƽ Bluetooth output power class 1 ƽ Bluetooth v3.0 with data rates 3.0Mbps ƽ Compliant to GSM phase 2/2+ -1- SIM800H Document Class 4 (2 W @ 850/900 MHz) – Class 1 (1 W @ 1800/1900MHz) Dimensions: 15.8*17.8*2.4 mm Weight: 1.25 g Control via AT commands (3GPP TS 27.007, 27.005 and SIMCom enhanced AT Commands) Supply voltage range 3.6~4.2 V Low power consumption Operation temperature:-30~80ć 88 LGA pads include – Interface to external SIM 3V/1.8V – Analog audio interface – RTC backup – Serial interface – USB interface – Keypad interface – LCD interface – Antenna pad – PCM – GPIO – ADC – ƽ ƽ ƽ ƽ ƽ ƽ ƽ -2- SIM800H Document 1.3. Pin 42 41 40 39 38 37 36 35 34 33 32 31 GND ANT GND GND GND BT_ ANT GND CTS RTS RXD GND SDA SCL GND GND GND UART _DCD UART _DTR VBAT VBAT GND GND GND GPIO GND STATUS ISINK1 BPI_ BUS1 ISINK0 GND PWR KEY 86 77 GND 78 85 87 84 88 83 TXD UART_ RI PCM OUT 30 GND PCM CLK 29 PCMIN GPIO 28 PCM SYNC GPIO 27 NETLI GHT PWM 26 ROW4 COL1 25 ROW0 COL4 24 ROW2 ROW3 23 ROW1 COL2 22 USB_DP VBUS RESET GND ADC MIC2P SPK2P 79 GND 81 80 82 MIC1P SPK1P SIM PRE SIM_ CLK VRTC FM_ ANT_N GND USB_ DP SIM_ DATA SIM_ RST VSIM FM_ ANT_P VDD EXT USB_ DM 14 15 16 17 18 MIC2N SPK2N MIC1N SPK1N 10 11 12 13 -3- 19 COL0 COL3 20 21 SIM800H Document 1.4. Picture FCC ID:UDV-2013072401 FCC ID:2013-072401 Figure 1: Top and Bottom view of SIM800H 1.5. Dimension Figure 2: Dimention -4- SIM800H Document 2. Detail Block Diagram Power supply RF Radio Frequency Power management unit BT FM RTC Digital Interface Analog Interface GPIOs Audio Analog base band UART SIM Digital base band ADC USB KEY Figure 3: Block diagram of SIM800H 3. Electrical and Reliability Characteristics 3.1. Absolute Maximum Ratings The absolute maximum ratings stated in following table are stress ratings under non-operating conditions. Stresses beyond any of these limits will cause permanent damage to SIM800H. Table 1: Absolute maximum ratings Symbol Parameter Min Typ Max Unit VBAT Power supply voltage 4.5 VBUS 30 VBUS II* Input current mA IO* Output current mA These parameters are for digital interface pins, such as keypad, GPIO, I2C, UART, LCD and DEBUG. 3.2. Digital Interface Characteristics Table 2: Digital interface characteristicsȱ -5- SIM800H Document Symbol Parameter Min Typ Max Unit IIH High-level input current 2.1 3.1 IIL Low-level input current -0.3 0.7 VOH High-level input voltage 2.4 VOL Low-level input voltage 0.4 * These parameters are for digital interface pins, such as keypad, GPIO, I C, UART, LCD, PWMs and DEBUG. 3.3. SIM Card Interface Characteristics Table 3: SIM card interface characteristicsȱ Symbol Parameter Min Typ Max Unit IIH High-level input current -1 uA IIL Low-level input current -1 uA VIH High-level input voltage 1.4 2.4 VIL Low-level input voltage 0.27 0.4 VOH High-level output voltage VOL Low-level output voltage 1.62 2.7 0.36 0.4 3.4. SIM_VDD Characteristics Table 4: SIM_VDD characteristicsȱ Symbol Parameter Min Typ Max Unit VO Output voltage 2.70 2.80 2.90 IO Output current 50 mA Min Typ Max Unit 3.5. VRTC Characteristics Table 5: VRTC characteristicsȱ Symbol Parameter VRTC-IN VRTC input voltage IRTC-IN VRTC input current uA VRTC-OUT VRTC output voltage 2.8 2.8 -6- SIM800H IRTC-OUT Document VRTC output current mA 3.6. Current Consumption (VBAT = 3.8V) Table 6: Current consumptionȱ Symbol Parameter Conditions Value Unit IVRTC VRTC current VBAT disconnects. Backup battery is 3 V uA Power down mode 50 uA Sleep mode BS-PA-MFRMS=9 1.0 BS-PA-MFRMS=5 1.2 BS-PA-MFRMS=2 1.8 mA GSM 850 Idle mode EGSM 900 19 DCS 1800 mA PCS 1900 GSM 850 EGSM 900 Voice call DCS 1800 PCS 1900 IVBAT GSM 850 EGSM 900 VBAT current Data mode GPRS(1Rx,1Tx) DCS 1800 PCS 1900 GSM 850 EGSM 900 Data mode GPRS(4Rx,1Tx) DCS 1800 PCS 1900 Data mode GPRS(3Rx,2Tx) GSM 850 EGSM 900 DCS 1800 PCS 1900 -7- PCL=5 250 PCL=12 110 PCL=19 76 PCL=0 168 PCL=7 89 PCL=15 76 PCL=5 240 PCL=12 110 PCL=19 83 PCL=0 170 PCL=7 95 PCL=15 80 PCL=5 270 PCL=12 150 PCL=19 120 PCL=0 205 PCL=7 130 PCL=15 115 PCL=5 440 PCL=12 185 PCL=19 130 PCL=0 300 PCL=7 155 mA mA mA mA mA mA mA SIM800H Document PCL=15 IVBAT-peak Peak current During Tx burst 122 3.7. Electro-Static Discharge SIM800H is an ESD sensitive component, so more attention should be paid to the procedure of handling and packaging. The ESD test results are shown in the following table. Table 7: The ESD characteristics (Temperature: 25ć, Humidity: 45 %) Pin Contact discharge Air discharge VBAT ±6KV ±12KV GND ±6KV ±12KV RXD, TXD ±2KV ±8KV Antenna port ±5KV ±10KV ±2KV ±5KV ±2KV ±8KV SPK_P/SPK_N/MIC_P/MIC_N PWRKEY 4. Radio Characteristics 4.1. Module RF Output Power The following table shows the module conducted output power, it is followed by the 3GPP TS 05.05 technical specification requirement. Table 8: SIM800H GSM 900 and GSM 850 conducted RF output power GSM850ǃEGSM900 PCL Tolerance (dB) for conditions Nominal output power (dBm) Normal Extreme 33 ±2 ±2.5 31 ±3 ±4 29 ±3 ±4 27 ±3 ±4 25 ±3 ±4 10 23 ±3 ±4 11 21 ±3 ±4 12 19 ±3 ±4 -8- SIM800H Document 13 17 ±3 ±4 14 15 ±3 ±4 15 13 ±3 ±4 16 11 ±5 ±6 17 ±5 ±6 18 ±5 ±6 19-31 ±5 ±6 Table 9: SIM800H DCS 1800 and PCS 1900 conducted RF output power DCS1800ǃPCS1900 PCL Nominal output power (dBm) Tolerance (dB) for conditions Normal Extreme 30 ±2 ±2.5 28 ±3 ±4 26 ±3 ±4 24 ±3 ±4 22 ±3 ±4 20 ±3 ±4 18 ±3 ±4 16 ±3 ±4 14 ±3 ±4 12 ±4 ±5 10 10 ±4 ±5 11 ±4 ±5 12 ±4 ±5 13 ±4 ±5 14 ±5 ±6 15 ±5 ±6 For the module’s output power, the following is should be noted: At GSM900 and GSM850 band, the module is a class 4 device, so the module’s output power should not exceed 33dBm, and at the maximum power level, the output power tolerance should not exceed +/-2dB under normal condition and +/-2.5dB under extreme condition. At DCS1800 and PCS1900 band, the module is a class 1 device, so the module’s output power should not exceed 30dBm, and at the maximum power level, the output power tolerance should not exceed +/-2dB under normal condition and +/-2.5dB under extreme condition. -9- SIM800H Document 4.2. Module RF Receive Sensitivity The following table shows the module’s conducted receive sensitivity, it is tested under static condition. Table 10: SIM800H conducted RF receive sensitivity Frequency Receive sensitivity˄Typical˅ Receive sensitivity(Max) GSM850 -108dBm -106dBm EGSM900 -108dBm -106dBm DCS1800 -108dBm -106dBm PCS1900 -108dBm -106dBm 4.3. Module Operating Frequencies The following table shows the module’s operating frequency range; it is followed by the 3GPP TS 05.05 technical specification requirement. Table 11: SIM800H operating frequencies Frequency Receive Transmit GSM850 869 ~ 894MHz 824 ~ 849 MHz EGSM900 925 ~ 960MHz 880 ~ 915MHz DCS1800 1805 ~ 1880MHz 1710 ~ 1785MHz PCS1900 1930 ~ 1990MHz 1850 ~ 1910MHz 5. Antenna interface There are three antenna ports for SIM800H, GSM antenna port named RF_ANT, Bluetooth antenna port named BT_ANT and FM antenna port named FM_ANT_P, The RF interface of the three antenna ports has an impedance of 50.The maximum gain of the GSM antenna gain should not exceed 3dBi considering the SAR radio. And the maximum gain of the Bluetooth antenna gain shout not exceed 2dBi.1RDQWHQQDJDLQPD\EHXVHG WKDWZRXOGH[FHHGWKH:(,53SRZHUOLPLWLQ0+]EDQG z The input impendence of the antenna should be 50, and the VSWR should be less than 2. z It is recommended that the GSM antenna and the BT antenna be placed as far as better. z The isolations of the three antenna should be bigger than 30d% 5.1 GSM Antenna Interface There is a GSM antenna pad named RF_ANT for SIM800H the connection of the antenna must be decoupled from DC voltage. This is necessary because the antenna connector is DC coupled to ground via an inductor for ESD protection. The external antenna must be matched properly to achieve best performance, so the matching circuit is necessary, the connection is recommended as following: - 10 - SIM800H Document Figure1: GSM antenna matching circuit R101ˈC101ˈC102 are the matching circuit, the value should be defined by the antenna design. normally R101 is 0, C101 ઼ C102 are not SMD. The RF connector is used for conducted 5.2 Bluetooth antenna interface The module provides a Bluetooth antenna interface named BT_ANT. The external antenna must be matched properly to achieve best performance, so the matching circuit is necessary, the connection is recommended as following figure: GND Module BT Antenna R201 BT_ANT C201 C202 GND Figure 5: BT antenna matching circuit R201ˈC201ˈC202 are the matching circuit, the value should be defined by the antenna design. R201 is recommended as 1.2NH and C202 is 1.5pF, C201 are not SMD. There are some suggestions to components placing and lying for GSM and Bluetooth RF traces: z The RF connector is used for conducted test, so keep it as close as pin RF_ANT; z Antenna matching circuit should be closed to the antenna; z Keep the RF traces as 50˗ z The RF traces should be kept far away from the high frequency signals and strong disturbing source. - 11 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : jiaxing.ye Create Date : 2013:08:10 13:30:18+08:00 Modify Date : 2013:08:10 13:30:18+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : jiaxing.ye Title : Microsoft Word - UDV-2013072401_User Manual_Rev 01.doc Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:08:10 13:29:26+08:00 Producer : Acrobat Distiller 9.5.5 (Windows) Document ID : uuid:9e5e9fe4-6909-405b-a1da-7d3d88d384f3 Instance ID : uuid:3f9e5a2b-faf2-4d1f-be9a-473e19b51bde Page Count : 11EXIF Metadata provided by EXIF.tools