Smarfid Security Equipment LFR Card Reader User Manual Mounting

Shanghai Smarfid Security Equipment Co, Ltd. Card Reader Mounting

User Manual

Keypad & Proximity Reader Installation Manual FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.
Keypad & Proximity Reader Installation Manual   Operation is subject to the following two conditions:   (1) this device may not cause interference, and   (2) this device must accept any interference, including interference that may cause undesired operation of the device.                                        IC STATEMENT Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Keypad & Proximity Reader Installation Manual    Parts o  1 - reader o  1 - Installation manual  Required Tools o  Up to 9 wire splices (pigtail) o  Cable, 5-9 conductor (Weigand or RS232), 24 AWG shielded (pigtail) o  Linear DC power supply o  Gang box (optional) o  Security tool for anti tamper screw Mounting 1.  Fasten the metal base plate to the wall with two or four screws to the wall or gang box (optional) 1 (gang box not included). 2.  Clip the top edge of the cover 2, followed by the bottom edge of the reader 3.  3.  Secure the reader to the base plate by fastening the security screw at the base of the reader 4. Installation is completed. Specifications Input voltage   (Reader end)  DC10V~15V  Average read range  > 6cm Operating current 160mA (max)  Maximum cable length 150m Operating temperature  -30ºC~70 ºC  Number pad format  4 bits burst by default Recommendations 1.  Linear DC Power Supply 2.  22AWG shielded cable; “One-point” ground recommended (refer to diagram)           Wiring Color  Label  Description Red  +12VDC  Power Supply to reader Black  GND  Signal GND Green  Data0  Wiegand Output data, D0 White  Data1  Wiegand Output data, D1 Yellow  RED LED  RED LED control, active low Blue  Green LED  Green LED control, active low
Keypad & Proximity Reader Installation Manual Brown  Buzzer  Buzzer input, active low Grey  Tamper  Tamper output (open collector, Active low, max 100mA) Purple  Doorbell  Door bell output (open collector, +5Vdc output ≤ 5mA) Troubleshooting Power & Testing 1.  When reader is powered up, the blue LED will light up. The orange LED will flicker for 5 seconds. The reader will beep once for 1 second and the reader is in Ready mode. 2.  Present the card. The orange LED will flicker once; the back lit will light for 5 seconds; buzzer will beep once.   3.  For keypad readers, the back light and the keypad numeral will light when the keypad is pressed; the buzzer will beep once  Using the Configuration Card (For keypad readers only) The default keypad format is “00”. The Configuration Card is required when the default keypad format is not compatible with the controller.   1.  When reader is powered up, the blue LED will light up. The orange LED will flicker for 5 seconds.  2.  Present the Configuration Card for the required format. A 1-second beep indicates a successful attempt. The new keypad format is saved.   Configuration cards are available for: o 4 bits   ○   Apollo 6 bits o 8 bits   ○      26 bits (Fixed Facility Code 190)  Physical Dimension        Symptom  Solution o  Disconnect the power and confirm that the power supply cable is correctly connected (Refer to Wiring table)  No response when power up  o  Check the input voltage is sufficient (Refer to Specifications table) o  Check the input voltage is sufficient ( Refer to Specifications table) Auto restart o  Verify that the format setting on the controller is the same as the card format. Use approved card (known format and Facility Code) to test Card number not read correctly  o  Check that the shield cable is correctly connected to Chassis Ground at ONE point only o  Check that Data 0 and Data 1 cable are correctly connected (Refer to Wiring table). Reader beeps but no card data  o  Check the input voltage at the card reader end is correct (Refer to Specifications table) o  Verify that the buzzer cable is correctly connected (Refer to Wiring table) No buzzer soundo  Verify that the LED cable is correctly connected (Refer to Wiring table) Back lit error o  Use the default Configuration Card to reset to default setting
Low Frequency Mullion Mount Reader Installation Manual Mounting: 1.  Install the back plate on the wall as shown in the diagram below1.  2.  The cover shall clip on the upper edge 2 the push in the bottom part as show in diagram3.  3.  Tighten the non-dropout screw, which located underneath of the reader to fix the reader and the back plate4, installation is completed.    Specification:    Recommendation: 1.  Linear DC Power Supply; 2.  22AWG shielded cable; it’s required to do “one-point” ground. (As shown in the diagram)    Wiring:  Input Voltage (at Reader end)  DC9V~15V  Typical Read range  > 5cm Operating Current  120mA (max)  Maximum Cable Length  150m Operating Temperature  -30ºC~70 ºC    Color  Label  Description Red  +12V dc  Power Supply to the reader Black  GND  Signal GND Green  RS232+/RS485+  RS232+/RS485+ White  RS232-/RS485-  RS232-/RS485- Yellow  RED LED  RED LED control, active low. Blue  Green LED  Green LED control, active low Brown  Buzzer  Buzzer input, active low Grey  Tamper  Tamper output (open collector, Active low, max 100mA)
Low Frequency Mullion Mount Reader Installation Manual  Power up Sequences: 1.  When reader is powered up, the reader will flash in Green for 5 seconds . Then the Reader is ready. 2.  Blue back lit stays on when the reader is ready.   3.  When card is present and read by the reader, blue back lit will flash once; and buzzer will beep once as well. The card data will then transmit to the controller. After, weather the back lit of the reader will remain ON or Flash or change to Green or Red color, this shall depend on the Green and Red LED inputs.  Physical Dimension:  Troubleshooting:                    Trouble List  Solution No Response when Power Up z  Discount the power and confirm that the power supply cable is correctly connected (See “Wiring” above). z  Check the input voltage is sufficient (See “Specifications” above). Auto Restart  z Check the input voltage is sufficient (See “Specifications” above). Cannot read card number correctlyz  Check the format setting on the controller if it is the same as the card format. Use approved card (known format and Facility Code) to test. z  Check if the shield cable is correctly connected to Classis Ground at ONE point only. Reader beeps but No card data infoz  Check if data 0 & data 1 cable is correctly connected (See “Wiring” above). z  Check the input voltage at the card reader end is correct (See “Specifications” above). Buzzer error  z  Check if the buzzer cable is correctly connected (See “Wiring” above). Back Lit Error  z  Check the Led cable is correctly connected (See “Wiring” above). z  Use Default Configuration Card to set it back to normal.