Smarfid Security Equipment LFR Card Reader User Manual Mounting
Shanghai Smarfid Security Equipment Co, Ltd. Card Reader Mounting
User Manual
Keypad & Proximity Reader Installation Manual FCC STATEMENT frequency energy and, if not installed and used in 1. This device complies with Part 15 of the FCC Rules. accordance with the instructions, may cause harmful Operation is subject to the following two conditions: interference to radio communications. However, there is (1) This device may not cause harmful interference. no guarantee that interference will not occur in a (2) This device must accept any interference received, particular installation. If this equipment does cause including interference that may cause undesired harmful interference to radio or television reception, operation. which can be determined by turning the equipment off and 2. Changes or modifications not expressly approved by the on, the user is encouraged to try to correct the party responsible for compliance could void the user's interference by one or more of the following measures: authority to operate the equipment. Reorient or relocate the receiving antenna. NOTE: This equipment has been tested and found to Increase the separation between the equipment and comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Keypad & Proximity Reader Installation Manual Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. IC STATEMENT Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Keypad & Proximity Reader Installation Manual Parts 1 - reader 1 - Installation manual Operating current 160mA (max) Maximum cable length Operating temperature -30ºC~70 ºC Number pad format Up to 9 wire splices (pigtail) Cable, 5-9 conductor (Weigand or RS232), 24 AWG shielded (pigtail) Linear DC power supply Gang box (optional) Security tool for anti tamper screw 1. Linear DC Power Supply 2. 22AWG shielded cable; “One-point” ground recommended (refer to diagram) Mounting Fasten the metal base plate to the wall with two or four screws to the wall or gang box (optional) 1 (gang box not included). 2. Clip the top edge of the cover 2, followed by the bottom edge of the reader 3. 3. Secure the reader to the base plate by fastening the security screw at the base of the reader 4. Wiring Installation is completed. Color Specifications Input voltage (Reader end) 4 bits burst by default Recommendations Required Tools 1. 150m DC10V~15V Average read range > 6cm Label Description Red +12VDC Power Supply to reader Black GND Signal GND Green Data0 Wiegand Output data, D0 White Data1 Wiegand Output data, D1 Yellow RED LED RED LED control, active low Blue Green LED Green LED control, active low Keypad & Proximity Reader Installation Manual Brown Buzzer Buzzer input, active low Grey Tamper Tamper output (open collector, Active low, max 100mA) Doorbell Door bell output (open collector, +5Vdc output ≤ 5mA) Troubleshooting Power & Testing 1. Purple When reader is powered up, the blue LED will light up. The orange LED will flicker for 5 Symptom Solution seconds. The reader will beep once for 1 second and the reader is in Ready mode. 2. Present the card. The orange LED will flicker once; the back lit will light for 5 seconds; buzzer will beep once. 3. No response when power up For keypad readers, the back light and the keypad numeral will light when the keypad is pressed; the buzzer will beep once Auto restart Disconnect the power and confirm that the power supply cable is correctly connected (Refer to Wiring table) Check the input voltage is sufficient (Refer to Specifications table) Check the input voltage is sufficient ( Refer to Specifications table) Verify that the format setting on the controller is the same as the card format. Use approved card (known format and Facility Code) to test Check that the shield cable is correctly connected to Chassis Ground at ONE point only Using the Configuration Card (For keypad readers only) The default keypad format is “00”. The Configuration Card is required when the default keypad format is not compatible with the controller. 1. When reader is powered up, the blue LED will light up. The orange LED will flicker for 5 Card number not read correctly seconds. 2. Present the Configuration Card for the required format. A 1-second beep indicates a successful attempt. The new keypad format is saved. Configuration cards are available for: 4 bits ○ Apollo 6 bits 8 bits ○ 26 bits (Fixed Facility Code 190) Reader beeps but no card data No buzzer sound Check that Data 0 and Data 1 cable are correctly connected (Refer to Wiring table). Check the input voltage at the card reader end is correct (Refer to Specifications table) Verify that the buzzer cable is correctly connected (Refer to Wiring table) Verify that the LED cable is correctly connected (Refer to Wiring table) Use the default Configuration Card to reset to default setting Physical Dimension Back lit error Low Frequency Mullion Mount Reader Installation Manual Mounting: Recommendation: 1. Install the back plate on the wall as shown in the diagram below1. 2. The cover shall clip on the upper edge 2 the push in the bottom part as show in 1. Linear DC Power Supply; 2. 22AWG shielded cable; it’s required to do “one-point” ground. (As shown in the diagram) diagram3. 3. Tighten the non-dropout screw, which located underneath of the reader to fix the reader and the back plate4, installation is completed. Wiring: Specification: Input Voltage (at Reader end) Operating Current Operating Temperature DC9V~15V 120mA (max) -30ºC~70 ºC Typical Read range Maximum Cable Length > 5cm 150m Color Label Description Red +12V dc Black GND Green RS232+/RS485+ RS232+/RS485+ White RS232-/RS485- RS232-/RS485- Yellow RED LED RED LED control, active low. Blue Green LED Green LED control, active low Brown Buzzer Buzzer input, active low Grey Tamper Tamper output (open collector, Active low, max 100mA) Power Supply to the reader Signal GND Low Frequency Mullion Mount Reader Installation Manual Power up Sequences: 1. When reader is powered up, the reader will flash in Green for 5 seconds . Then the Reader is ready. 2. Blue back lit stays on when the reader is ready. 3. When card is present and read by the reader, blue back lit will flash once; and buzzer will beep once as well. The card data will then transmit to the controller. After, weather the back lit of the reader will remain ON or Flash or change to Green or Red color, this shall depend on the Green and Red LED inputs. Physical Dimension: Troubleshooting: Trouble List No Response when Power Up Auto Restart Solution correctly connected (See “Wiring” above). Check the input voltage is sufficient (See “Specifications” above). Check the input voltage is sufficient (See “Specifications” above). Check the format setting on the controller if it is the same as the card format. Use approved card (known format and Facility Code) to test. Cannot read card number correctly Discount the power and confirm that the power supply cable is Check if the shield cable is correctly connected to Classis Ground at ONE point only. above). Reader beeps but No card data info Check if data 0 & data 1 cable is correctly connected (See “Wiring” Check the input voltage at the card reader end is correct (See “Specifications” above). Buzzer error Back Lit Error Check if the buzzer cable is correctly connected (See “Wiring” above). Check the Led cable is correctly connected (See “Wiring” above). Use Default Configuration Card to set it back to normal.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-702 Modify Date : 2010:09:16 14:14:35+08:00 Create Date : 2010:09:16 14:14:35+08:00 Metadata Date : 2010:09:16 14:14:35+08:00 Creator Tool : Acrobat PDFMaker 7.0 for Word Format : application/pdf Title : Mounting: Creator : 雨林木风 Document ID : uuid:603d9690-ee75-4104-94c4-4dca05cb8f40 Instance ID : uuid:a251103e-db84-4b07-ae04-e6c4ae0416db Producer : Acrobat Distiller 7.0.5 (Windows) Page Count : 6 Author : 雨林木风 Company : WwW.lenovo.CoMEXIF Metadata provided by EXIF.tools