SmartLabs MM01 Micro Module User Manual Relay

SmartLabs, Inc. Micro Module Users Manual Relay

Users Manual Relay

Download: SmartLabs MM01 Micro Module User Manual Relay
Mirror Download [FCC.gov]SmartLabs MM01 Micro Module User Manual Relay
Document ID1725107
Application IDuP9wsrbRrzD84HCAgGKdqw==
Document DescriptionUsers Manual Relay
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize3.41kB (42640 bits)
Date Submitted2012-06-18 00:00:00
Date Available2012-06-18 00:00:00
Creation Date2012-05-17 13:55:42
Producing SoftwareAcrobat Distiller 10.1.2 (Windows)
Document Lastmod2012-05-17 13:55:42
Document TitleMicrosoft Word - Micro Module Relay User Manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: mmeyer

Set button
Quick Start Guide
Terminal #1
(Line)
INSTEON® Micro Relay
Off button
On button
Terminal #2
(Load)
Terminals #3 and
#4 (Neutral)
Model: 2443-222/2443-422/2443-522
About INSTEON Micro Relay
Congratulations on your purchase of the INSTEON® Micro Relay!
This compact on/off relay module wires in behind an existing wall
switch to give you complete—and completely hidden—remote
control over compatible lights.
Note: Installation should only be performed by a qualified
electrician or a homeowner who is familiar and comfortable with
electrical circuitry. If you have questions, consult an electrician or
call the INSTEON Support Line at 800-762-7845.
Set button
In the Box
- INSTEON Micro Relay
What’s Needed
- Flathead screwdriver
- Philips screwdriver
- Wire cutter/stripper
- Voltage meter
Installing INSTEON Micro Relay (Dual Momentary Switch)
1)
2)
3)
Before installing, write down Micro Relay’s INSTEON I.D. (on sticker) for future reference.
Turn off breaker/fuse and verify that the power is off.
Remove wallplate and unscrew existing switch.
4)
Gently pull switch out of wall and disconnect wires.2
5)
After ensuring that the wires are not touching, turn breaker back on.
6)
Use a voltage meter to identify the fixture’s Line, Load and Neutral wires.
7)
Turn off breaker again.
8)
Connect Micro Relay wires as follows:
Micro Relay
House
Terminal #1
Line (100-277VAC)
Terminal #2
Load (light, fan, etc.)
Terminal #3
Neutral
Terminal #4
Neutral
Micro Relay
9)
Switch
Yellow wire
Momentary on
Purple wire
Momentary off
Turn breaker back on.
Connected load will turn on and Micro Relay’s LED will turn on green.
10) Test connection by tapping Micro Relay’s on/off buttons.
Connected load will turn on and off and Micro Relay’s LED will turn green (on) and red (off).
If multi-gang box, turn off all breakers/fuses that may be supplying power to the box.
If the wires cannot be detached, cut wires where they enter the switch and strip ½” of insulation off the ends.
2443-222 Rev. 5/17/2012 1:55 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
11) If you are planning to manually link Micro Relay to any INSTEON controllers, do so now (see Adding Micro Relay
as an INSTEON Responder below).
12) Turn breaker off.
13) Place Micro Relay in rear of wall box.
14) Remount switch in wall box.
15) Turn breaker back on.
Connected load will turn on at its previous state (prior to turning off breaker).
16) Test installation by tapping switch on and off.
Connected load will turn on and off.
17) Reinstall wallplate.
Installing INSTEON Micro Relay (Single Momentary Switch)
1)
2)
3)
Before installing, write down Micro Relay’s INSTEON I.D. (on sticker) for future reference.
Turn off breaker/fuse and verify that the power is off.
Remove wallplate and unscrew existing switch.
4)
Gently pull switch out of wall and disconnect wires.2
5)
After ensuring that the wires are not touching, turn breaker back on.
6)
Use a voltage meter to identify the fixture’s Line, Load and Neutral wires.
7)
Turn off breaker again.
8)
Connect Micro Relay wires as follows:
Micro Relay
House
Terminal #1
Line (100-277VAC)
Terminal #2
Load (light, fan, etc.)
Terminal #3
Neutral
Terminal #4
Neutral
Micro Relay
9)
Switch
Yellow wire
Switch contact
Purple wire
Not used – cap off
Turn breaker back on.
Connected load will turn on and Micro Relay’s LED will turn on green.
10) Test connection by tapping Micro Relay’s on/off buttons.
Connected load will turn on and off and Micro Relay’s LED will turn green (on) and red (off).
11) If you are planning to manually link Micro Relay to any INSTEON controllers, do so now (see Adding Micro Relay
as an INSTEON Responder below).
12) Turn breaker off.
13) Place Micro Relay in rear of wall box.
14) Remount switch in wall box.
15) Turn breaker back on.
Connected load will turn on at its previous state (prior to turning off breaker).
16) Test installation by tapping switch on and off.
Connected load will turn on and off.
17) Reinstall wallplate.
If multi-gang box, turn off all breakers/fuses that may be supplying power to the box.
If the wires cannot be detached, cut wires where they enter the switch and strip ½” of insulation off the ends.
2443-222 Rev. 5/17/2012 1:55 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
Installing INSTEON Micro Relay (Behind Wall Outlet/Socket)
1)
2)
3)
Before installing, write down Micro Relay’s INSTEON I.D. (on sticker) for future reference.
Turn off breaker/fuse and verify that the power is off.
Remove wallplate and unscrew existing outlet.
4)
Gently pull switch out of wall and disconnect wires.2
5)
After ensuring that the wires are not touching, turn breaker back on.
6)
Use a voltage meter to identify the fixture’s Line, Load and Neutral wires.
7)
Turn off breaker again.
8)
Connect Micro Relay wires as follows:
Micro Relay
Terminal #1
House
Line (100-277VAC)
Terminal #2
Load (light, fan, etc.)
Terminal #3
Neutral
Terminal #4
Neutral
Micro Relay
9)
Switch
Yellow wire
Not used – cap off
Purple wire
Not used – cap off
Turn breaker back on.
Micro Relay’s LED will turn on green and outlet will be powered.
10) Test connection: plug a lamp into the outlet, then tap Micro Relay’s on/off buttons.
Lamp will turn on and off and Micro Relay’s LED will turn green (on) and red (off).
11) If you are planning to manually link Micro Relay to any INSTEON controllers, do so now (see Adding Micro Relay
as an INSTEON Responder below).
12) Turn breaker off.
13) Place Micro Relay in rear of wall box.
14) Remount outlet in wall box.
15) Turn breaker back on.
Outlet will be powered.
16) Reinstall wallplate.
Adding Micro Relay as an INSTEON Responder
We recommend using INSTEON SmartLinc and the free INSTEON iOS/Android smartphone and tablet app or home
automation software (such as HouseLinc) to add and monitor Micro Relay on your home network. You can also add
Micro Relay to your network manually by following the instructions below. Note: you must perform these steps before
reinstalling the wall switch.
1) Press and hold controller’s ON/scene button until it beeps.
Controller’s LED will start blinking green.
2) Adjust load connected to Micro Relay to desired brightness level.
3)
Press and hold Micro Relay’s Set button until it double-beeps.
4)
Controller will double-beep and its LED will stop blinking.
Test link by tapping controller’s ON/scene button on and off.
The load connected to Micro Relay will turn on and off.
If multi-gang box, turn off all breakers/fuses that may be supplying power to the box.
If the wires cannot be detached, cut wires where they enter the switch and strip ½” of insulation off the ends.
2443-222 Rev. 5/17/2012 1:55 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
Adding Micro Relay as an INSTEON Controller
We recommend using INSTEON SmartLinc and the free INSTEON iOS/Android smartphone and tablet app or home
automation software (such as HouseLinc) to add and monitor Micro Relay on your home network. You can also add
Micro Relay to your network manually by following the instructions below. Note: you must perform these steps before
reinstalling the wall switch.
1) Press and hold Micro Relay’s Set button until it beeps.
Micro Relay’s LED will start blinking green.
2) Adjust responder to desired state.
3)
Press and hold responder’s Set button until it double-beeps.
4)
Micro Relay will double-beep and its LED will stop blinking.
Test link by tapping Micro Relay’s paddle top and bottom to turn on/off.
The responder turn on and off.
FCC Compliance
This device complies with FCC Rules Part 15. Operation is subject to two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference that may be received or that may cause undesired
operation.
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in residential installations. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio and television reception. However, there is no guarantee that interference
will not occur in a particular installation. If
this device does cause such interference, which can be verified by turning the device off and on, the user
is encouraged to eliminate the interference by one or more of the following measures:
• Re-orient or re-locate the receiving antenna of the device experiencing the interference.
• Increase the distance between this device and the receiver.
• Connect the device to an AC outlet on a circuit different from the one that supplies power to the
receiver.
• Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this device not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Industry Canada Compliance
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of that device.
Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorise aux deux conditions suivantes: (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le
brouillage est susceptible d'en compromettre le fonctionnement.
Owner’s Manual and Tech Support
Owner’s Manual and Quick Start Guide: http://www.insteon.com/support
Call: INSTEON Support Line at 800-762-7845
2443-222 Rev. 5/17/2012 1:55 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : mmeyer
Create Date                     : 2012:05:17 13:55:42-07:00
Modify Date                     : 2012:05:17 13:55:42-07:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - Micro Module Relay User Manual.doc
Creator                         : mmeyer
Producer                        : Acrobat Distiller 10.1.2 (Windows)
Document ID                     : uuid:2b3c0cc1-ac0c-49fc-9ea1-7d533fd69e62
Instance ID                     : uuid:3ecd8732-d665-480f-993b-158b1dd2cb31
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SBPMM01

Navigation menu