Naída UltraPower
User Guide
Your hearing care professional
029-0435-02/V1.00/2007-11/A+W Printed in Switzerland © Phonak AG All rights reserved
www.phonak.com
™
0459
0682
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 2
Contents
Welcome
Description
Naída UltraPower hearing system with earmold 7
Naída UltraPower is water resistant!
Short introduction
Inserting the battery
Switching ON/OFF
Controlling the volume
Selecting a hearing program
10
10
Preparation
Replacing the battery
Tamperproof battery compartment
Low battery warning
Identifying left and right hearing systems
Inserting Naída hearing system with
earmold into your ear
Secure ‘n Stay - an optional retention
11
11
12
15
16
18
21
Operation
Switching ON/OFF
FM system
Delayed activation
Controlling the volume
23
23
24
25
26
Selecting a hearing program
Telecoil (optional)
EasyPhone
28
29
30
myPilot (optional)
33
iCom (optional)
36
FM communication (optional)
Design-integrated FM receiver ML10i
Universal FM receiver
Attaching and removing audio shoe (AS10)
EasyFM
Manual selection of a FM program
Multi-frequency FM transmitter
38
39
44
45
48
48
49
Maintenance
Naída UltraPower is water resistant!
Wind and Weather Protector
Important points
50
50
52
55
Warning
58
Service and Warranty
59
Phonak distributors worldwide
62
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 4
Welcome
Your new Naída UltraPower hearing system uses the
very latest advances in digital wireless hearing
technology. Naída UltraPower offers you, automatically,
the highest sound quality, speech understanding
and listening comfort in all your hearing situations.
High-tech has turned highly sophisticated hearing
systems into convenient devices that are easy to use.
Please read this manual carefully to benefit from all
the features of your new Naída hearing system.
Ask your hearing care professional if you have any
questions.
Naída UltraPower is a quality product developed by the
Swiss company Phonak, a world leader in hearing
technology, innovation and reliability. With proper care
and usage, your Naída hearing system will support
your hearing and communication needs for many years.
If you want additional information about Naída
UltraPower, please visit the Phonak website
www.phonak.com.
Phonak – life is on
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 6
Description
Naída UltraPower hearing system with earmold
햷
햲
햳
햸
햴
햵
Naída UltraPower is water resistant!
햶
햹
햲 Microphone inputs with Wind and Weather
Protector (water resistant) for microphones
햳 Program switch (TacTronic)
햴 Programming cover
햵 Volume control
햶 Battery compartment with ON/OFF switch
(for children – Junior models, with battery lock)
햷 Hook/sound output
햸 Individual earmold
햹 Wind and Weather Protector (water resistant)
for battery compartment
Thanks to the water resistant casing of Naída,
you will now have a new degree of freedom in your
daily life. The robust and dependable design of
Naída will allow you to benefit from amplification in
many more situations than before: during rigorous
labor, throughout strenuous exercise, while active
outdoors, or even when unexpectedly caught in the
rain.
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 8
Short introduction
Naída hearing systems, including the design-integrated
FM receiver (ML10i), are resistant to water, sweat and
dirt under the conditions listed below:
Inserting the battery
Details see page 12
• Battery compartment and programming cover are
fully closed
• All three Wind and Weather Protectors are mounted
correctly
• The hearing system is used and maintained as
described in this user guide
Do not wear your hearing systems while
showering, or washing your hair.
Do not wear your hearing systems while in the
water: they are not designed for any kind of
swimming or diving activities.
The Naída hearing systems are not designed for
immersion in water or other liquids.
After perspiration or contact with water, the
hearing system must be cleaned. Please refer to
the relevant section in this user guide on page 55.
Proper use and maintenance of your hearing
system will prolong its life span.
For more information regarding water resistance,
see page 50.
Switching ON/OFF
Details see page 23
ON
OFF
ON
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 10
Short introduction
Preparation
Controlling the volume
Details see page 26
Replacing the battery
Volume up
Volume down
Use standard batteries size 675 for all Naída UP
(UltraPower) models.
Using the nail grip, open the battery compartment
completely and remove the old battery 햲, 햳, 햴.
햴
햳
Selecting a hearing program
Details see page 28
햲
Remove the protective foil
from the new battery.
10
11
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 12
Preparation
Insert the new battery with the “+” sign (flat side of
the battery) in line with the “+” marked on the battery
cover 햵, 햶. Push the battery door upwards to close it
햷.
햶
햷
The battery can only be inserted when the latch is
open 햺. Move the latch over the inserted battery 햻
so that it lies against it. Lock the battery by pushing
towards the hearing instrument with your finger 햽.
Before you close the battery compartment, check that
the latch is locked in position and the battery can’t
be removed.
햽
햵
햻
Tamperproof battery compartment
For the Junior models (Naída III UP Jr and Naída V UP Jr)
the battery is locked inside the battery compartment
for safety reasons. The latch can easily be opened with
a fingernail. Place the fingernail in the groove and pull
the latch away from the hearing instrument 햸 and
then push it upwards 햹.
햸
12
햹
햺
The tamperproof battery compartment is also
available for the design-integrated FM receiver and
the universal receiver audio shoe.
13
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 14
Preparation
Handle the battery compartment with care and
do not use excessive force.
If there is any resistance when shutting the
compartment, ensure that the battery is inserted
correctly.
If the battery is installed backwards, the
instrument will not work. Please open the battery
compartment and insert the battery correctly.
For the Junior models, the battery latch must be
placed back over the battery and locked,
before closing the battery compartment.
The battery compartment must be completely
closed to ensure that the hearing instrument is
water resistant.
When your hearing system is not in use, leave
the battery compartment open to allow any
moisture to evaporate.
We recommend to only use batteries which your
hearing care professional approves and sells.
14
Low battery warning
An acoustic signal gives you an early warning that the
battery is approaching exhaustion. You have usually
at least 30 minutes to replace the battery. With very
high quality batteries, this reserve may be higher. The
hearing system will repeat the low battery warning
approximately every 30 minutes.
15
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 16
Preparation
Identifying left and right hearing systems
It is important to use the correct hearing system for
each ear.
If you have a design-integrated FM solution (ML10i)
mounted on your hearing systems, the color code is
situated on the ML10i module identifying left and right
hearing systems, refer to the drawing below.
Your hearing care professional can mark the hearing
systems for you. The color code on the lower part
of the battery compartment will identify left and right
hearing systems.
The color code is as follows:
blue = left
blue = left
16
red = right
red = right
17
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 18
Preparation
Inserting Naída
hearing system
with earmold into
your ear
Using the hand on the same side you wear your
hearing system, grasp the earmold between the thumb
and index finger.
Place the canal portion of the earmold inside your ear
canal. If it is difficult to get it into place, stretch your
ear by pulling it gently backwards and upwards with
your other hand. When the canal portion is in place,
twist the earmold backwards so that it fits into the
concha and the helix portion is under the fold.
Now position the hearing
system behind the ear.
Be careful not to twist the
tubing.
Raise your hand to your ear, making sure the canal
portion of the earmold faces your ear. Tilt your hand
slightly forward.
18
19
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 20
Preparation
Secure ‘n Stay - an optional retention
Secure ‘n Stay is an optional retention that can be easily
mounted on the hearing instrument 햲, 햳.
Check the placement of the earmold by tracing the
contour of the ear with your finger.
To remove your hearing system, grasp the earmold,
not the tubing, and pull it out of your ear gently but
firmly.
햲
20
햳
21
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 22
Preparation
Operation
Secure ‘n Stay supports the retention of the hearing
instrument behind the ear 햴, 햵 and gives extra
comfort during sport activities, when playing, etc. Ask
your hearing care professional for more information.
Switching ON/OFF
햴
Switching OFF
햵
Using the nail grip, slightly open the battery cover
until it snaps to its OFF position.
It can also be used if a FM system is attached to your
hearing instrument.
Note:
Before using Secure 'n Stay, please carefully read the
instructions.
22
23
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 24
Operation
Switching ON
Delayed activation
Your hearing care professional may have delayed
the activation of your Naída hearing system after
switching ON (9 or 15 seconds), in order to avoid
any disturbance while placing it on your ear.
The activation is confirmed by an acoustic signal.
Close the battery compartment. Your Naída hearing
systems are always working in the initial hearing
program, and at the preset volume when turned ON.
FM system
Switching ON/OFF on a design-integrated ML10i FM
or on an universal FM receiver with an audio shoe
(see page 41 resp. 44) can easily be done as described
above.
24
25
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 26
Operation
Controlling the volume
The volume of your Naída hearing system can be
adjusted above or below the preset volume.
Volume up
Volume down
26
Note:
• A beep confirms each action on the volume
control. A double beep indicates that you have
reached the limit of your volume control range.
• The volume control switch can be replaced
with a locked version, specially designed for small
children. Your hearing care professional can
easily do this adaptation. The volume control can
then only be operated via myPilot (see page 33),
or by hand using a pin-shaped item, like a pen. To
be pressed on the upper resp. lower part of the
volume control as on page 26.
QuickSync – controlling two hearing instruments
An automatic synchronization for volume adjustments
and program selection, QuickSync, is integrated in
Naída V UP models. Users wearing two hearing instruments
have to activate the functionality on one instrument
and the other instrument will be adjusted automatically.
Your hearing care professional may have deactivated
this wireless syncronization.
27
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 28
Operation
Selecting a hearing program
Automatic program selection
The program selection in Naída is fully automatic.
Naída recognizes different hearing environments and
automatically selects the most appropriate hearing
program.
Additional program selection
Upon request, your hearing care professional can program
for you additional individual hearing programs dedicated
to specific hearing situation or FM (wireless
communication) use. Additional programs are available
via myPilot (see page 33) and/or with the program
switch.
QuickSync - controlling two hearing instruments
QuickSync, an automatic synchronization for volume
adjustments and program selection is integrated in
Naída V UP models. Users wearing two hearing
instruments have to activate the functionality on one
instrument and the other instrument will be adjusted
automatically. Your hearing care professional may have
deactivated this wireless syncronization.
28
Important
Ask your hearing care professional to print out
the complete description of your individual hearing
programs and how to access them with your myPilot
and/or your program switch.
Program switch (TacTronic)
The program switch allows manual toggling between
the “Automatic Mode”, “Mute Mode” and individual
hearing programs. A short melody confirms the selection
of the “Automatic Mode”.
Telecoil (optional)
Your hearing care professional may have activated a
telecoil (T-coil) in your Naída hearing systems. The
programs with T-coil are used to listen to telephones
that are compatible with hearing system or via
inductive loop systems (present in some school settings,
theaters, churches, etc.) as well as other wireless
solutions (e.g. Phonak MyLink FM system).
29
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 30
Operation
EasyPhone
The EasyPhone function enables your Naída hearing
system to automatically select your telephone program
when the telephone handset is held close to your ear.
An acoustic signal confirms the switching.
It automatically returns to the previous hearing program
when the telephone handset is removed from your ear.
Some telephones produce a magnetic field strong enough
to activate your EasyPhone function. Most types of
telephones require an additional magnet fixed on the
receiver to activate this function.
Fixing the EasyPhone magnet
Clean the telephone handset
thoroughly.
Hold the telephone handset nearly
vertically, similarly to making
a telephone call. Hold the magnet
near to the “listening end” of your
telephone handset and release it.
The magnet will automatically flip
to the correct side.
30
If you hold the telephone
receiver in your right hand
when making telephone
calls, position the magnet in
the upper right half of the
receiver.
If you hold the telephone
receiver in your left hand
when making telephone
calls, position the magnet
in the upper left half of
the receiver.
Use the double-sided adhesive
tape to stick the magnet to
the location described above.
Do not cover the sound
openings of your handset.
31
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 32
Operation
myPilot (optional)
Use of EasyPhone
Use the telephone in a normal manner. An acoustic
signal indicates the activation of the EasyPhone
program. At the beginning, you may need to move the
handset slightly to find the optimum position for a
reliable switching and comfortable hearing.
The myPilot command center is an optional accessory
for all Naída systems. It allows a convenient, user
friendly and discrete control of all the functions of your
hearing system and offers additional benefits.
If necessary, move the magnet to another position on
the handset to increase your comfort of use.
Keep magnets out of reach of children and pets.
If a magnet is swallowed, please seek the advice
of a medical practitioner.
The magnet used to strengthen the magnetic
field of your phone may affect some medical
devices or electronic systems.
Always keep the magnet (or the telephone
equipped with the magnet) at least 30 cm (12”)
away from pacemakers, credit cards, floppy disks
or other magnetically sensitive devices.
Too high distortion during dialing or phoning
may mean that the phone receiver is stressed by
the magnet. To avoid any damage, please move
the magnet to another place on the telephone
receiver.
32
•
•
•
•
•
Volume control
Program selection
Automatic mode selection
Clock and Alarm
Battery status
For detailed information on the use of your myPilot,
please refer to its user guide or ask your hearing care
professional.
33
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 34
myPilot (optional)
myPilot is available in two stylish colors:
high-tech gray or white.
For optimum results, position your myPilot as shown
in the drawing.
Operating range
max. 50 cm (20”)
Do not use your myPilot in locations where
it is forbidden to use electronic devices, for
instance on airplanes.
34
35
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 36
iCom (optional)
iCom is an optional accessory
available for all Naída
instruments. With the push
of a single button, iCom
connects your hearing system
with the technology
around you (mobile phones,
audio equipment, FM, etc.).
FM compatibility
iCom also offers FM accessibility when a universal
Phonak FM receiver is connected.
Bluetooth connections
iCom offers a simple way to connect your mobile
phone via Bluetooth to your hearing system.
iCom is also capable of transmitting a stereo
audio signal from any Bluetooth enabled device
(built-in or via an adapter) such as MP3 players,
laptops, computers and televisions.
36
Do not use your iCom in locations where
it is forbidden to use electronic devices, for
instance on airplanes.
37
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 38
FM communication (optional)
Your Naída hearing system is equipped with Direct
Audio Input (DAI). It allows you to fully benefit from
the high-end FM systems from Phonak.
FM systems greatly improve communication when
noise, distance or reverberation is a problem. A wireless
FM communication system consists of a transmitter
and a receiver. The transmitter transmits the signal to
the receiver.
For more information about the use of FM receivers
or transmitters, please refer to the appropriate user
guide or ask your hearing care professional.
FM solutions for Naída
Phonak offers two FM solutions for your Naída hearing
system:
1. Design-integrated FM receiver (see below)
2. Universal FM receiver (see page 44)
1. Design-integrated FM receiver ML10i
ML10i: Perfectly integrated in
the Naída design
for daily use.
Switching ON/OFF on the hearing system can easily
be done (see page 23).
38
39
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 40
FM communication (optional)
Naída UltraPower hearing system with
design-integrated FM receiver (ML10i)
햷
햲
햳
햸
햴
햵
햶
햲 Microphone inputs with Wind and Weather Protector
(water resistant) for microphones
햳 Program switch (TacTronic)
햴 Programming cover
햵 Volume control
햶 Battery compartment with ON/OFF switch
(for children - Junior models, with battery lock)
햷 Hook / sound output
햸 Individual earmold
햹 Wind and Weather Protector (water resistant) for
battery compartment
햺 Design-integrated FM receiver
햺
햹
40
41
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 42
FM communication (optional)
Naída UltraPower with the design-integrated FM
solution is water resistant
Thanks to the water resistant casing of Naída, you will
now have a new degree of freedom in your daily life.
The robust and dependable design of Naída will allow
you to benefit from amplification in many more situations
than before: during rigorous labor, throughout strenuous
exercise, while active outdoors, or even when
unexpectedly caught in the rain.
Naída hearing systems, including the design-integrated
FM receiver (ML10i), are resistant to water, sweat and
dirt under the conditions listed below:
• Battery compartment and programming cover are
fully closed
• All three Wind and Weather Protectors are mounted
correctly
• The hearing system is used and maintained as
described in this user guide
42
Do not wear your hearing systems while showering,
or washing your hair.
Do not wear your hearing systems while in the
water: they are not designed for any kind of
swimming or diving activities.
The Naída hearing systems are not designed for
immersion in water or other liquids.
After perspiration or contact with water, the
hearing system must be cleaned. Please refer to the
relevant section in this user guide on page 55.
Proper use and maintenance of your hearing system
will prolong its life span.
For more information regarding water resistance,
see page 50.
43
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 44
FM communication (optional)
2. Universal FM receiver
MLxi: Together with the
audio shoe
interface, AS10.
It can be removed if FM is not in use. ON/OFF
function of the hearing system, see page 23.
It can be removed if FM is not in use. ON/OFF function
of the hearing system, see page 23.
Note:
To have FM immediately active when required, Phonak
recommends to leave the MicroMLxS attached when
not in use. If required, MicroMLxS can easily be siwtched
off by setting the switch to the OFF position “ ”, see
photo page 44.
°
Attaching and removing the audio shoe (AS10)
Note:
To have FM immediately active when required,
Phonak recommends to leave the MLxi attached when
not in use. If required, MLxi can easily be switched
off by pressing the button.
MicroMLxS: together with the
audio shoe
interface, AS10.
Set the MicroMLxS swith
to the position “•” for use.
44
Your hearing care professional has already prepared
your Naída hearing system (with a special battery
compartment) for use with a FM receiver, MLxi.
To attach the audio shoe AS10, firmly hold it in your
hand and push the small black locking systems together
with the bottom of the hearing system 햲, see page 46.
Note:
Naída hearing systems, modified with the special
battery compartment (allowing use of the audio shoe
and connected universal FM receiver) are no longer
water resistant.
45
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 46
FM communication (optional)
햵
햲
햴
햳
햲
Pull the hearing system upwards
with the other hand 햵.
Then, push the hearing system
down until it snaps in 햳.
햳
“click”
When not in use, the receiver automatically switches
to a low power stand-by mode.
To remove the audio shoe, place the hearing system
on a firm surface, hold the audio shoe firmly and slide
the locking system 햴.
46
Note:
To have FM immediately active when required,
Phonak recommends to leave the MLxi attached when
not in use. If required MLxi can easily be switched
off by pressing the button.
47
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 48
FM communication (optional)
EasyFM
Multi-frequency FM transmitter
The EasyFM function automatically selects your FM
program when an FM receiver is connected to your
hearing system in mode “A” (automatic) and an FM
signal is detected. An acoustic signal confirms the
switching. The hearing system switches back to “A”
when the FM signal is turned off.
Phonak offers a wide range of different
FM transmitters:
inspiro – the transmitter for a range
of educational applications
You can always manually override the EasyFM function
with the program switch or a remote control.
SmartLink – flexible multifunctional
transmitter with Bluetooth
Manual selection of a FM program
ZoomLink – convenient transmitter
with three microphone settings
• Program switch (if activated by your hearing care
professional): toggle until you reach the desired
FM program, identified by the appropriate acoustic
signal.
EasyLink – the easy-to-use transmitter
48
• myPilot (if activated by your hearing care
professional): choose your desired FM program. The
selection is confirmed by an acoustic signal.
49
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 50
Maintenance
Naída UltraPower is water resistant!
Thanks to the water resistant casing of Naída, you will
now have a new degree of freedom in your daily life.
The robust and dependable design of Naída will allow
you to benefit from amplification in many more
situations than before: during rigorous labor, throughout
strenuous exercise, while active outdoors, or even
when unexpectedly caught in the rain.
Naída hearing systems, including the design-integrated
FM receiver (ML10i), are resistant to water, sweat and
dirt under the conditions listed below:
• Battery compartment and programming cover are
fully closed
• All three Wind and Weather Protectors are mounted
correctly
• The hearing system is used and maintained as
described in this user guide
50
Do not wear your hearing systems while showering,
or washing your hair.
Do not wear your hearing systems while in the
water: they are not designed for any kind of
swimming or diving activities.
The Naída hearing systems are not designed for
immersion in water or other liquids.
After perspiration or contact with water, the
hearing system must be cleaned. Please refer to the
relevant section in this user guide on page 55.
Proper use and maintenance of your hearing system
will prolong its life span.
Note:
Naída hearing systems, modified with the special
battery compartment (allowing use of the audio shoe
and connected universal FM receiver) are no longer
water resistant.
Note:
In case the hearing systems stop working after accidental
immersion in water, please take the following actions:
- open the battery compartment, dry the casing and the
inside of the battery compartment with a soft cloth or
a tissue and replace the battery.
51
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 52
Maintenance
Wind and Weather Protector
Important: The three Wind and Weather Protectors are
exclusive to Phonak hearing systems, designed to
protect the high-tech microphones and the battery air
inlet from dust, humidity or water.
The life span of the Wind and Weather Protector
should be up to several months, depending on the
environment (humidity, dust, perspiration, etc.). The
Wind and Weather Protectors should not be cleaned
but replaced regularly.
52
Your hearing systems should never be used without
the Wind and Weather Protectors. If they are not
mounted properly, the hearing system is not water
resistant (see page 50).
The following care and maintenance tips will help
extend the life span and ensure the efficiency of your
protectors:
Never wipe or clean the Wind and Weather
Protector – it may lose its special acoustic and
protection properties.
The Wind and Weather Protector is made of
three identical parts. Always replace all three
protectors together.
Hair spray, make-up, etc. may damage or clog
the Wind and Weather Protector. Remove your
hearing system before applying cosmetics.
Avoid touching the Wind and Weather Protector
when you place an instrument on your ear or
press the program switch.
53
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 54
Maintenance
Important: Consult your hearing care professional
about changing the Wind and Weather Protector if you
experience any of the following:
•
•
•
•
The hearing system sounds quieter than usual
There is a reduction in sound quality
Understanding in noise becomes more difficult
It becomes more difficult to determine the
direction of sounds
After some experience, you will get to know when the
Wind and Weather Protector needs to be replaced. It is
advisable to have it replaced before the hearing system
performance is affected.
Important points
1) Always use new batteries as replacements. You
can return empty batteries to your hearing care
professional.
2) When your hearing system is not in use, leave
the battery compartment open in a clean place,
preferable the protective case, to allow any
moisture to evaporate.
3) If you will not be using your hearing systems for
any length of time, store them in their protective
case. Remove the batteries and leave the battery
compartments open. Make sure your hearing systems
are completely dry before closing the case.
4) In general, you have to protect your hearing systems
from excessive moisture and heat.
5) Your Naída hearing systems and the design-integrated
FM solution are water resistant, for more exact
handling read carefully page 50.
Note: Naída hearing systems, modified with the
special battery compartment (allowing use of the
54
55
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 56
Maintenance
audio shoe and connected universal FM receiver)
are no longer water resistant.
6) Do not leave hearing systems near windows or in
a car. Avoid strong jolts and vibration.
7) Daily cleaning and the use of a drying system is
highly recommended. C&C Line from Phonak is
a complete set of cleaning products. Your hearing
care professional will be glad to advise you.
Never use household cleaning products (washing
powder, soap, etc.) to clean your hearing
systems.
8) Hair spray, face creams and make-up can damage
hearing systems. Remove the hearing systems
before applying cosmetics.
reasons, please remember to bring your myPilot,
iCom, if you use one, together with your hearing
system(s) for service enquiries.
The symbol with the crossed out disposal bin
indicates that this hearing instrument shall not
be treated as household waste. Please hand
over your old or unused hearing instrument to
the applicable collection point for the recycling
of electrical and electronic equipment or bring
your old hearing instrument to your hearing care
professional for appropriate disposal.
By ensuring this product is disposed of correctly,
you will help prevent potential negative effects
on the environment and human health.
9) If you experience any soreness or inflammation
in or behind your ear, contact your hearing care
professional.
10) If your hearing system fails to operate after you
have correctly inserted new batteries, contact your
hearing care professional for advice. For coding
56
57
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 58
Warning
Hearing system batteries are toxic when swallowed!
Keep them out of reach of children and pets. If
batteries are swallowed, please seek the advice of
a medical practitioner!
Use only hearing systems that have been specially
programmed for you by a hearing care professional.
Other instruments may be ineffective and may, in
certain cases, even damage your hearing.
X-ray radiation (e.g. CT scans, MRI scans) may
adversely affect the correct functioning of
your instruments. We recommend that you remove
them before undergoing X-ray procedures and
keep them outside the room.
Hearing systems in directional microphone
mode reduce mainly background sounds. Warning
signals coming from behind and vehicles’ horns
approaching from behind are partially or completely
suppressed.
58
Service and Warranty
Phonak offers you a comprehensive global warranty
which becomes effective on the date of purchase. Please
ask your hearing care professional about the details and
duration. This warranty covers any repairs due to defects
in material and/or workmanship. The warranty does not
cover damage from improper handling or care, exposure
to chemicals, immersion in water or undue stress.
Damage caused by third parties or non-authorized service
centers renders the Phonak warranty null and void. This
warranty does not include any services performed by
a hearing care professional in their office. This warranty
applies to the Phonak products listed below:
Hearing instrument
Serial number
instrument – right:
FM receivers
Serial number
FM receiver – right:
Serial number
instrument – left:
Serial number
FM receiver – left:
Date of purchase:
Date of purchase:
59
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 60
Notices
Notice 1
This instrument is certified under:
FCC ID: KWC-WHSBTE
IC: 2262A-WHS
This device complies with Part 15 of the FCC Rules
and with RSS-210 of Industry Canada. Operation is
subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications made to this equipment
not expressly approved by Phonak may void the FCC
authorization to operate this equipment.
Notice 2
This Class B digital apparatus complies with Canadian
ICES-003.
60
Notice 3
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment
and receiver
• Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV
technician for help
61
P58243_Pho_GB_Naida.qxp
30.11.2007
15:13 Uhr
Seite 62
Phonak distributors worldwide
Group companies:
Australia
Austria
Belgium
Brazil
Canada
China
Denmark
France
Germany
Italy
Japan
Jordan
Mexico
Netherlands
New Zealand
Norway
Poland
Russian Federation
62
(detailed information on
www.phonak.com)
Phonak Australasia Pty. Ltd.
Baulkham Hills N. S. W. 2153
Hansaton Akustische Geräte GmbH
5020 Salzburg
Ets Lapperre B.H.A.C. NV
B-1702 Groot-Bijgaarden
Phonak Belgium NV, B-1700 Dilbeek
CAS Produtos Médicos
São Paulo – SP 04363-100
Phonak Canada Limited
Mississauga, Ontario L5S 1V9
Phonak (Shanghai) Co. Ltd.,
Shanghai City 200233
Phonak Danmark A/S, Nitivej 10
2000 Frederiksberg
Phonak France SA, 69500 Bron
Phonak GmbH, 70736 Fellbach-Oeffingen
EC Representative
Phonak Italia S.r.l., 20159 Milano
Phonak Japan Co., Ltd., Tokyo 101-0044
Phonak Middle East, 11181 Amman
Phonak Mexicana, S.A. de C.V. 03920
México, D.F.MEXICO
Phonak B.V., 3439 ME Nieuwegein
Phonak New Zealand Ltd., Takapuna
Auckland 9
Phonak AS, 0105 Oslo
Phonak Polska Sp. z o.o., 00-567 Warszawa
Phonak CIS Ltd., Moscow, 115114
Spain
Sweden
Switzerland
United Kingdom
USA
Independent general
distributors:
Manufacturer:
Phonak Ibérica S.A., 03008 Alicante
Phonak AB, 117 43 Stockholm
Phonak AG, Phonak Schweiz, 8712 Stäfa
Phonak UK Limited
Warrington, Cheshire WA1 1PP
Phonak LLC, Warrenville, IL 60555-3927
A complete list of Phonak distributors
is available at Phonak's Internet site:
www.phonak.com
Please visit us or ask your hearing
care professional for information.
Phonak AG, Laubisrütistrasse 28
CH-8712 Stäfa, Switzerland
63
P58243_Pho_GB_Naida.qxp
XXXX
30.11.2007
15:13 Uhr
Seite 64
The CE symbol is a confirmation by
Phonak AG that Naída products and
accessories meet the requirements
of directive 93/42/EEC on medical devices
and the R&TTE Directive 1999/5/EC on
Radio and Telecommunication Terminal
Equipment.
The numbers after the CE symbol are the
numbers of consulted certified bodies
under the above mentioned directives.
The alert sign means that potential
restrictions on its use are applicable in
one or more EU Member States.
This symbol indicates that Naída
products comply with requirements for
a BF type applied part according
to EN 60601-1.
64
Safety notice
External devices may only be connected
if they have been tested in accordance
with corresponding IECXXXXX standards.
Only use accessories approved by
Phonak AG.
Operating
conditions
The hearing system has been designed
for trouble-free operation under all
ordinary climatic conditions.
T ra n s p o r t a t i o n a n d
storage conditions
Temperature should not exceed limits of
–20°/60° Celsius at a relative air humidity
of 65% for extended periods during
transportation and storage. Air pressure
between 500 and 1100 hPa is not
detrimental to the instrument.
Australia & New Zealand
Brazil
China
Japan
South Korea
0459
0682
65
P58243_Pho_GB_Naida.qxp
Notes
30.11.2007
15:13 Uhr
Seite 66

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Modify Date                     : 2007:11:30 15:13:58+01:00
Create Date                     : 2007:11:30 15:13:58+01:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:85abc33b-9f4e-11dc-8d2e-0017f20b61e2
Instance ID                     : uuid:85ac0cbe-9f4e-11dc-8d2e-0017f20b61e2
Page Count                      : 34
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KWC-WHSBTE

Navigation menu