Sonova USA WHSBTE Hearing Aid User Manual
Phonak Inc Hearing Aid
Contents
- 1. User Manual Exelia
- 2. User Manual Naida
User Manual Naida
P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 201 Naída UltraPower User Guide Your hearing care professional 029-0435-02/V1.00/2007-11/A+W Printed in Switzerland © Phonak AG All rights reserved www.phonak.com ™ 0459 0682 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 2 Contents Welcome Description Naída UltraPower hearing system with earmold 7 Naída UltraPower is water resistant! Short introduction Inserting the battery Switching ON/OFF Controlling the volume Selecting a hearing program 10 10 Preparation Replacing the battery Tamperproof battery compartment Low battery warning Identifying left and right hearing systems Inserting Naída hearing system with earmold into your ear Secure ‘n Stay - an optional retention 11 11 12 15 16 18 21 Operation Switching ON/OFF FM system Delayed activation Controlling the volume 23 23 24 25 26 Selecting a hearing program Telecoil (optional) EasyPhone 28 29 30 myPilot (optional) 33 iCom (optional) 36 FM communication (optional) Design-integrated FM receiver ML10i Universal FM receiver Attaching and removing audio shoe (AS10) EasyFM Manual selection of a FM program Multi-frequency FM transmitter 38 39 44 45 48 48 49 Maintenance Naída UltraPower is water resistant! Wind and Weather Protector Important points 50 50 52 55 Warning 58 Service and Warranty 59 Phonak distributors worldwide 62 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 4 Welcome Your new Naída UltraPower hearing system uses the very latest advances in digital wireless hearing technology. Naída UltraPower offers you, automatically, the highest sound quality, speech understanding and listening comfort in all your hearing situations. High-tech has turned highly sophisticated hearing systems into convenient devices that are easy to use. Please read this manual carefully to benefit from all the features of your new Naída hearing system. Ask your hearing care professional if you have any questions. Naída UltraPower is a quality product developed by the Swiss company Phonak, a world leader in hearing technology, innovation and reliability. With proper care and usage, your Naída hearing system will support your hearing and communication needs for many years. If you want additional information about Naída UltraPower, please visit the Phonak website www.phonak.com. Phonak – life is on P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 6 Description Naída UltraPower hearing system with earmold 햷 햲 햳 햸 햴 햵 Naída UltraPower is water resistant! 햶 햹 햲 Microphone inputs with Wind and Weather Protector (water resistant) for microphones 햳 Program switch (TacTronic) 햴 Programming cover 햵 Volume control 햶 Battery compartment with ON/OFF switch (for children – Junior models, with battery lock) 햷 Hook/sound output 햸 Individual earmold 햹 Wind and Weather Protector (water resistant) for battery compartment Thanks to the water resistant casing of Naída, you will now have a new degree of freedom in your daily life. The robust and dependable design of Naída will allow you to benefit from amplification in many more situations than before: during rigorous labor, throughout strenuous exercise, while active outdoors, or even when unexpectedly caught in the rain. P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 8 Short introduction Naída hearing systems, including the design-integrated FM receiver (ML10i), are resistant to water, sweat and dirt under the conditions listed below: Inserting the battery Details see page 12 • Battery compartment and programming cover are fully closed • All three Wind and Weather Protectors are mounted correctly • The hearing system is used and maintained as described in this user guide Do not wear your hearing systems while showering, or washing your hair. Do not wear your hearing systems while in the water: they are not designed for any kind of swimming or diving activities. The Naída hearing systems are not designed for immersion in water or other liquids. After perspiration or contact with water, the hearing system must be cleaned. Please refer to the relevant section in this user guide on page 55. Proper use and maintenance of your hearing system will prolong its life span. For more information regarding water resistance, see page 50. Switching ON/OFF Details see page 23 ON OFF ON P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 10 Short introduction Preparation Controlling the volume Details see page 26 Replacing the battery Volume up Volume down Use standard batteries size 675 for all Naída UP (UltraPower) models. Using the nail grip, open the battery compartment completely and remove the old battery 햲, 햳, 햴. 햴 햳 Selecting a hearing program Details see page 28 햲 Remove the protective foil from the new battery. 10 11 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 12 Preparation Insert the new battery with the “+” sign (flat side of the battery) in line with the “+” marked on the battery cover 햵, 햶. Push the battery door upwards to close it 햷. 햶 햷 The battery can only be inserted when the latch is open 햺. Move the latch over the inserted battery 햻 so that it lies against it. Lock the battery by pushing towards the hearing instrument with your finger 햽. Before you close the battery compartment, check that the latch is locked in position and the battery can’t be removed. 햽 햵 햻 Tamperproof battery compartment For the Junior models (Naída III UP Jr and Naída V UP Jr) the battery is locked inside the battery compartment for safety reasons. The latch can easily be opened with a fingernail. Place the fingernail in the groove and pull the latch away from the hearing instrument 햸 and then push it upwards 햹. 햸 12 햹 햺 The tamperproof battery compartment is also available for the design-integrated FM receiver and the universal receiver audio shoe. 13 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 14 Preparation Handle the battery compartment with care and do not use excessive force. If there is any resistance when shutting the compartment, ensure that the battery is inserted correctly. If the battery is installed backwards, the instrument will not work. Please open the battery compartment and insert the battery correctly. For the Junior models, the battery latch must be placed back over the battery and locked, before closing the battery compartment. The battery compartment must be completely closed to ensure that the hearing instrument is water resistant. When your hearing system is not in use, leave the battery compartment open to allow any moisture to evaporate. We recommend to only use batteries which your hearing care professional approves and sells. 14 Low battery warning An acoustic signal gives you an early warning that the battery is approaching exhaustion. You have usually at least 30 minutes to replace the battery. With very high quality batteries, this reserve may be higher. The hearing system will repeat the low battery warning approximately every 30 minutes. 15 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 16 Preparation Identifying left and right hearing systems It is important to use the correct hearing system for each ear. If you have a design-integrated FM solution (ML10i) mounted on your hearing systems, the color code is situated on the ML10i module identifying left and right hearing systems, refer to the drawing below. Your hearing care professional can mark the hearing systems for you. The color code on the lower part of the battery compartment will identify left and right hearing systems. The color code is as follows: blue = left blue = left 16 red = right red = right 17 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 18 Preparation Inserting Naída hearing system with earmold into your ear Using the hand on the same side you wear your hearing system, grasp the earmold between the thumb and index finger. Place the canal portion of the earmold inside your ear canal. If it is difficult to get it into place, stretch your ear by pulling it gently backwards and upwards with your other hand. When the canal portion is in place, twist the earmold backwards so that it fits into the concha and the helix portion is under the fold. Now position the hearing system behind the ear. Be careful not to twist the tubing. Raise your hand to your ear, making sure the canal portion of the earmold faces your ear. Tilt your hand slightly forward. 18 19 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 20 Preparation Secure ‘n Stay - an optional retention Secure ‘n Stay is an optional retention that can be easily mounted on the hearing instrument 햲, 햳. Check the placement of the earmold by tracing the contour of the ear with your finger. To remove your hearing system, grasp the earmold, not the tubing, and pull it out of your ear gently but firmly. 햲 20 햳 21 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 22 Preparation Operation Secure ‘n Stay supports the retention of the hearing instrument behind the ear 햴, 햵 and gives extra comfort during sport activities, when playing, etc. Ask your hearing care professional for more information. Switching ON/OFF 햴 Switching OFF 햵 Using the nail grip, slightly open the battery cover until it snaps to its OFF position. It can also be used if a FM system is attached to your hearing instrument. Note: Before using Secure 'n Stay, please carefully read the instructions. 22 23 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 24 Operation Switching ON Delayed activation Your hearing care professional may have delayed the activation of your Naída hearing system after switching ON (9 or 15 seconds), in order to avoid any disturbance while placing it on your ear. The activation is confirmed by an acoustic signal. Close the battery compartment. Your Naída hearing systems are always working in the initial hearing program, and at the preset volume when turned ON. FM system Switching ON/OFF on a design-integrated ML10i FM or on an universal FM receiver with an audio shoe (see page 41 resp. 44) can easily be done as described above. 24 25 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 26 Operation Controlling the volume The volume of your Naída hearing system can be adjusted above or below the preset volume. Volume up Volume down 26 Note: • A beep confirms each action on the volume control. A double beep indicates that you have reached the limit of your volume control range. • The volume control switch can be replaced with a locked version, specially designed for small children. Your hearing care professional can easily do this adaptation. The volume control can then only be operated via myPilot (see page 33), or by hand using a pin-shaped item, like a pen. To be pressed on the upper resp. lower part of the volume control as on page 26. QuickSync – controlling two hearing instruments An automatic synchronization for volume adjustments and program selection, QuickSync, is integrated in Naída V UP models. Users wearing two hearing instruments have to activate the functionality on one instrument and the other instrument will be adjusted automatically. Your hearing care professional may have deactivated this wireless syncronization. 27 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 28 Operation Selecting a hearing program Automatic program selection The program selection in Naída is fully automatic. Naída recognizes different hearing environments and automatically selects the most appropriate hearing program. Additional program selection Upon request, your hearing care professional can program for you additional individual hearing programs dedicated to specific hearing situation or FM (wireless communication) use. Additional programs are available via myPilot (see page 33) and/or with the program switch. QuickSync - controlling two hearing instruments QuickSync, an automatic synchronization for volume adjustments and program selection is integrated in Naída V UP models. Users wearing two hearing instruments have to activate the functionality on one instrument and the other instrument will be adjusted automatically. Your hearing care professional may have deactivated this wireless syncronization. 28 Important Ask your hearing care professional to print out the complete description of your individual hearing programs and how to access them with your myPilot and/or your program switch. Program switch (TacTronic) The program switch allows manual toggling between the “Automatic Mode”, “Mute Mode” and individual hearing programs. A short melody confirms the selection of the “Automatic Mode”. Telecoil (optional) Your hearing care professional may have activated a telecoil (T-coil) in your Naída hearing systems. The programs with T-coil are used to listen to telephones that are compatible with hearing system or via inductive loop systems (present in some school settings, theaters, churches, etc.) as well as other wireless solutions (e.g. Phonak MyLink FM system). 29 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 30 Operation EasyPhone The EasyPhone function enables your Naída hearing system to automatically select your telephone program when the telephone handset is held close to your ear. An acoustic signal confirms the switching. It automatically returns to the previous hearing program when the telephone handset is removed from your ear. Some telephones produce a magnetic field strong enough to activate your EasyPhone function. Most types of telephones require an additional magnet fixed on the receiver to activate this function. Fixing the EasyPhone magnet Clean the telephone handset thoroughly. Hold the telephone handset nearly vertically, similarly to making a telephone call. Hold the magnet near to the “listening end” of your telephone handset and release it. The magnet will automatically flip to the correct side. 30 If you hold the telephone receiver in your right hand when making telephone calls, position the magnet in the upper right half of the receiver. If you hold the telephone receiver in your left hand when making telephone calls, position the magnet in the upper left half of the receiver. Use the double-sided adhesive tape to stick the magnet to the location described above. Do not cover the sound openings of your handset. 31 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 32 Operation myPilot (optional) Use of EasyPhone Use the telephone in a normal manner. An acoustic signal indicates the activation of the EasyPhone program. At the beginning, you may need to move the handset slightly to find the optimum position for a reliable switching and comfortable hearing. The myPilot command center is an optional accessory for all Naída systems. It allows a convenient, user friendly and discrete control of all the functions of your hearing system and offers additional benefits. If necessary, move the magnet to another position on the handset to increase your comfort of use. Keep magnets out of reach of children and pets. If a magnet is swallowed, please seek the advice of a medical practitioner. The magnet used to strengthen the magnetic field of your phone may affect some medical devices or electronic systems. Always keep the magnet (or the telephone equipped with the magnet) at least 30 cm (12”) away from pacemakers, credit cards, floppy disks or other magnetically sensitive devices. Too high distortion during dialing or phoning may mean that the phone receiver is stressed by the magnet. To avoid any damage, please move the magnet to another place on the telephone receiver. 32 • • • • • Volume control Program selection Automatic mode selection Clock and Alarm Battery status For detailed information on the use of your myPilot, please refer to its user guide or ask your hearing care professional. 33 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 34 myPilot (optional) myPilot is available in two stylish colors: high-tech gray or white. For optimum results, position your myPilot as shown in the drawing. Operating range max. 50 cm (20”) Do not use your myPilot in locations where it is forbidden to use electronic devices, for instance on airplanes. 34 35 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 36 iCom (optional) iCom is an optional accessory available for all Naída instruments. With the push of a single button, iCom connects your hearing system with the technology around you (mobile phones, audio equipment, FM, etc.). FM compatibility iCom also offers FM accessibility when a universal Phonak FM receiver is connected. Bluetooth connections iCom offers a simple way to connect your mobile phone via Bluetooth to your hearing system. iCom is also capable of transmitting a stereo audio signal from any Bluetooth enabled device (built-in or via an adapter) such as MP3 players, laptops, computers and televisions. 36 Do not use your iCom in locations where it is forbidden to use electronic devices, for instance on airplanes. 37 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 38 FM communication (optional) Your Naída hearing system is equipped with Direct Audio Input (DAI). It allows you to fully benefit from the high-end FM systems from Phonak. FM systems greatly improve communication when noise, distance or reverberation is a problem. A wireless FM communication system consists of a transmitter and a receiver. The transmitter transmits the signal to the receiver. For more information about the use of FM receivers or transmitters, please refer to the appropriate user guide or ask your hearing care professional. FM solutions for Naída Phonak offers two FM solutions for your Naída hearing system: 1. Design-integrated FM receiver (see below) 2. Universal FM receiver (see page 44) 1. Design-integrated FM receiver ML10i ML10i: Perfectly integrated in the Naída design for daily use. Switching ON/OFF on the hearing system can easily be done (see page 23). 38 39 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 40 FM communication (optional) Naída UltraPower hearing system with design-integrated FM receiver (ML10i) 햷 햲 햳 햸 햴 햵 햶 햲 Microphone inputs with Wind and Weather Protector (water resistant) for microphones 햳 Program switch (TacTronic) 햴 Programming cover 햵 Volume control 햶 Battery compartment with ON/OFF switch (for children - Junior models, with battery lock) 햷 Hook / sound output 햸 Individual earmold 햹 Wind and Weather Protector (water resistant) for battery compartment 햺 Design-integrated FM receiver 햺 햹 40 41 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 42 FM communication (optional) Naída UltraPower with the design-integrated FM solution is water resistant Thanks to the water resistant casing of Naída, you will now have a new degree of freedom in your daily life. The robust and dependable design of Naída will allow you to benefit from amplification in many more situations than before: during rigorous labor, throughout strenuous exercise, while active outdoors, or even when unexpectedly caught in the rain. Naída hearing systems, including the design-integrated FM receiver (ML10i), are resistant to water, sweat and dirt under the conditions listed below: • Battery compartment and programming cover are fully closed • All three Wind and Weather Protectors are mounted correctly • The hearing system is used and maintained as described in this user guide 42 Do not wear your hearing systems while showering, or washing your hair. Do not wear your hearing systems while in the water: they are not designed for any kind of swimming or diving activities. The Naída hearing systems are not designed for immersion in water or other liquids. After perspiration or contact with water, the hearing system must be cleaned. Please refer to the relevant section in this user guide on page 55. Proper use and maintenance of your hearing system will prolong its life span. For more information regarding water resistance, see page 50. 43 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 44 FM communication (optional) 2. Universal FM receiver MLxi: Together with the audio shoe interface, AS10. It can be removed if FM is not in use. ON/OFF function of the hearing system, see page 23. It can be removed if FM is not in use. ON/OFF function of the hearing system, see page 23. Note: To have FM immediately active when required, Phonak recommends to leave the MicroMLxS attached when not in use. If required, MicroMLxS can easily be siwtched off by setting the switch to the OFF position “ ”, see photo page 44. ° Attaching and removing the audio shoe (AS10) Note: To have FM immediately active when required, Phonak recommends to leave the MLxi attached when not in use. If required, MLxi can easily be switched off by pressing the button. MicroMLxS: together with the audio shoe interface, AS10. Set the MicroMLxS swith to the position “•” for use. 44 Your hearing care professional has already prepared your Naída hearing system (with a special battery compartment) for use with a FM receiver, MLxi. To attach the audio shoe AS10, firmly hold it in your hand and push the small black locking systems together with the bottom of the hearing system 햲, see page 46. Note: Naída hearing systems, modified with the special battery compartment (allowing use of the audio shoe and connected universal FM receiver) are no longer water resistant. 45 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 46 FM communication (optional) 햵 햲 햴 햳 햲 Pull the hearing system upwards with the other hand 햵. Then, push the hearing system down until it snaps in 햳. 햳 “click” When not in use, the receiver automatically switches to a low power stand-by mode. To remove the audio shoe, place the hearing system on a firm surface, hold the audio shoe firmly and slide the locking system 햴. 46 Note: To have FM immediately active when required, Phonak recommends to leave the MLxi attached when not in use. If required MLxi can easily be switched off by pressing the button. 47 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 48 FM communication (optional) EasyFM Multi-frequency FM transmitter The EasyFM function automatically selects your FM program when an FM receiver is connected to your hearing system in mode “A” (automatic) and an FM signal is detected. An acoustic signal confirms the switching. The hearing system switches back to “A” when the FM signal is turned off. Phonak offers a wide range of different FM transmitters: inspiro – the transmitter for a range of educational applications You can always manually override the EasyFM function with the program switch or a remote control. SmartLink – flexible multifunctional transmitter with Bluetooth Manual selection of a FM program ZoomLink – convenient transmitter with three microphone settings • Program switch (if activated by your hearing care professional): toggle until you reach the desired FM program, identified by the appropriate acoustic signal. EasyLink – the easy-to-use transmitter 48 • myPilot (if activated by your hearing care professional): choose your desired FM program. The selection is confirmed by an acoustic signal. 49 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 50 Maintenance Naída UltraPower is water resistant! Thanks to the water resistant casing of Naída, you will now have a new degree of freedom in your daily life. The robust and dependable design of Naída will allow you to benefit from amplification in many more situations than before: during rigorous labor, throughout strenuous exercise, while active outdoors, or even when unexpectedly caught in the rain. Naída hearing systems, including the design-integrated FM receiver (ML10i), are resistant to water, sweat and dirt under the conditions listed below: • Battery compartment and programming cover are fully closed • All three Wind and Weather Protectors are mounted correctly • The hearing system is used and maintained as described in this user guide 50 Do not wear your hearing systems while showering, or washing your hair. Do not wear your hearing systems while in the water: they are not designed for any kind of swimming or diving activities. The Naída hearing systems are not designed for immersion in water or other liquids. After perspiration or contact with water, the hearing system must be cleaned. Please refer to the relevant section in this user guide on page 55. Proper use and maintenance of your hearing system will prolong its life span. Note: Naída hearing systems, modified with the special battery compartment (allowing use of the audio shoe and connected universal FM receiver) are no longer water resistant. Note: In case the hearing systems stop working after accidental immersion in water, please take the following actions: - open the battery compartment, dry the casing and the inside of the battery compartment with a soft cloth or a tissue and replace the battery. 51 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 52 Maintenance Wind and Weather Protector Important: The three Wind and Weather Protectors are exclusive to Phonak hearing systems, designed to protect the high-tech microphones and the battery air inlet from dust, humidity or water. The life span of the Wind and Weather Protector should be up to several months, depending on the environment (humidity, dust, perspiration, etc.). The Wind and Weather Protectors should not be cleaned but replaced regularly. 52 Your hearing systems should never be used without the Wind and Weather Protectors. If they are not mounted properly, the hearing system is not water resistant (see page 50). The following care and maintenance tips will help extend the life span and ensure the efficiency of your protectors: Never wipe or clean the Wind and Weather Protector – it may lose its special acoustic and protection properties. The Wind and Weather Protector is made of three identical parts. Always replace all three protectors together. Hair spray, make-up, etc. may damage or clog the Wind and Weather Protector. Remove your hearing system before applying cosmetics. Avoid touching the Wind and Weather Protector when you place an instrument on your ear or press the program switch. 53 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 54 Maintenance Important: Consult your hearing care professional about changing the Wind and Weather Protector if you experience any of the following: • • • • The hearing system sounds quieter than usual There is a reduction in sound quality Understanding in noise becomes more difficult It becomes more difficult to determine the direction of sounds After some experience, you will get to know when the Wind and Weather Protector needs to be replaced. It is advisable to have it replaced before the hearing system performance is affected. Important points 1) Always use new batteries as replacements. You can return empty batteries to your hearing care professional. 2) When your hearing system is not in use, leave the battery compartment open in a clean place, preferable the protective case, to allow any moisture to evaporate. 3) If you will not be using your hearing systems for any length of time, store them in their protective case. Remove the batteries and leave the battery compartments open. Make sure your hearing systems are completely dry before closing the case. 4) In general, you have to protect your hearing systems from excessive moisture and heat. 5) Your Naída hearing systems and the design-integrated FM solution are water resistant, for more exact handling read carefully page 50. Note: Naída hearing systems, modified with the special battery compartment (allowing use of the 54 55 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 56 Maintenance audio shoe and connected universal FM receiver) are no longer water resistant. 6) Do not leave hearing systems near windows or in a car. Avoid strong jolts and vibration. 7) Daily cleaning and the use of a drying system is highly recommended. C&C Line from Phonak is a complete set of cleaning products. Your hearing care professional will be glad to advise you. Never use household cleaning products (washing powder, soap, etc.) to clean your hearing systems. 8) Hair spray, face creams and make-up can damage hearing systems. Remove the hearing systems before applying cosmetics. reasons, please remember to bring your myPilot, iCom, if you use one, together with your hearing system(s) for service enquiries. The symbol with the crossed out disposal bin indicates that this hearing instrument shall not be treated as household waste. Please hand over your old or unused hearing instrument to the applicable collection point for the recycling of electrical and electronic equipment or bring your old hearing instrument to your hearing care professional for appropriate disposal. By ensuring this product is disposed of correctly, you will help prevent potential negative effects on the environment and human health. 9) If you experience any soreness or inflammation in or behind your ear, contact your hearing care professional. 10) If your hearing system fails to operate after you have correctly inserted new batteries, contact your hearing care professional for advice. For coding 56 57 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 58 Warning Hearing system batteries are toxic when swallowed! Keep them out of reach of children and pets. If batteries are swallowed, please seek the advice of a medical practitioner! Use only hearing systems that have been specially programmed for you by a hearing care professional. Other instruments may be ineffective and may, in certain cases, even damage your hearing. X-ray radiation (e.g. CT scans, MRI scans) may adversely affect the correct functioning of your instruments. We recommend that you remove them before undergoing X-ray procedures and keep them outside the room. Hearing systems in directional microphone mode reduce mainly background sounds. Warning signals coming from behind and vehicles’ horns approaching from behind are partially or completely suppressed. 58 Service and Warranty Phonak offers you a comprehensive global warranty which becomes effective on the date of purchase. Please ask your hearing care professional about the details and duration. This warranty covers any repairs due to defects in material and/or workmanship. The warranty does not cover damage from improper handling or care, exposure to chemicals, immersion in water or undue stress. Damage caused by third parties or non-authorized service centers renders the Phonak warranty null and void. This warranty does not include any services performed by a hearing care professional in their office. This warranty applies to the Phonak products listed below: Hearing instrument Serial number instrument – right: FM receivers Serial number FM receiver – right: Serial number instrument – left: Serial number FM receiver – left: Date of purchase: Date of purchase: 59 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 60 Notices Notice 1 This instrument is certified under: FCC ID: KWC-WHSBTE IC: 2262A-WHS This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Phonak may void the FCC authorization to operate this equipment. Notice 2 This Class B digital apparatus complies with Canadian ICES-003. 60 Notice 3 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help 61 P58243_Pho_GB_Naida.qxp 30.11.2007 15:13 Uhr Seite 62 Phonak distributors worldwide Group companies: Australia Austria Belgium Brazil Canada China Denmark France Germany Italy Japan Jordan Mexico Netherlands New Zealand Norway Poland Russian Federation 62 (detailed information on www.phonak.com) Phonak Australasia Pty. Ltd. Baulkham Hills N. S. W. 2153 Hansaton Akustische Geräte GmbH 5020 Salzburg Ets Lapperre B.H.A.C. NV B-1702 Groot-Bijgaarden Phonak Belgium NV, B-1700 Dilbeek CAS Produtos Médicos São Paulo – SP 04363-100 Phonak Canada Limited Mississauga, Ontario L5S 1V9 Phonak (Shanghai) Co. Ltd., Shanghai City 200233 Phonak Danmark A/S, Nitivej 10 2000 Frederiksberg Phonak France SA, 69500 Bron Phonak GmbH, 70736 Fellbach-Oeffingen EC Representative Phonak Italia S.r.l., 20159 Milano Phonak Japan Co., Ltd., Tokyo 101-0044 Phonak Middle East, 11181 Amman Phonak Mexicana, S.A. de C.V. 03920 México, D.F.MEXICO Phonak B.V., 3439 ME Nieuwegein Phonak New Zealand Ltd., Takapuna Auckland 9 Phonak AS, 0105 Oslo Phonak Polska Sp. z o.o., 00-567 Warszawa Phonak CIS Ltd., Moscow, 115114 Spain Sweden Switzerland United Kingdom USA Independent general distributors: Manufacturer: Phonak Ibérica S.A., 03008 Alicante Phonak AB, 117 43 Stockholm Phonak AG, Phonak Schweiz, 8712 Stäfa Phonak UK Limited Warrington, Cheshire WA1 1PP Phonak LLC, Warrenville, IL 60555-3927 A complete list of Phonak distributors is available at Phonak's Internet site: www.phonak.com Please visit us or ask your hearing care professional for information. Phonak AG, Laubisrütistrasse 28 CH-8712 Stäfa, Switzerland 63 P58243_Pho_GB_Naida.qxp XXXX 30.11.2007 15:13 Uhr Seite 64 The CE symbol is a confirmation by Phonak AG that Naída products and accessories meet the requirements of directive 93/42/EEC on medical devices and the R&TTE Directive 1999/5/EC on Radio and Telecommunication Terminal Equipment. The numbers after the CE symbol are the numbers of consulted certified bodies under the above mentioned directives. The alert sign means that potential restrictions on its use are applicable in one or more EU Member States. This symbol indicates that Naída products comply with requirements for a BF type applied part according to EN 60601-1. 64 Safety notice External devices may only be connected if they have been tested in accordance with corresponding IECXXXXX standards. Only use accessories approved by Phonak AG. Operating conditions The hearing system has been designed for trouble-free operation under all ordinary climatic conditions. T ra n s p o r t a t i o n a n d storage conditions Temperature should not exceed limits of –20°/60° Celsius at a relative air humidity of 65% for extended periods during transportation and storage. Air pressure between 500 and 1100 hPa is not detrimental to the instrument. Australia & New Zealand Brazil China Japan South Korea 0459 0682 65 P58243_Pho_GB_Naida.qxp Notes 30.11.2007 15:13 Uhr Seite 66
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 for Macintosh Modify Date : 2007:11:30 15:13:58+01:00 Create Date : 2007:11:30 15:13:58+01:00 Format : application/pdf Title : untitled Document ID : uuid:85abc33b-9f4e-11dc-8d2e-0017f20b61e2 Instance ID : uuid:85ac0cbe-9f4e-11dc-8d2e-0017f20b61e2 Page Count : 34EXIF Metadata provided by EXIF.tools