Sony Group DTPT1000 DTP-T1000 Development Tool User Manual DTP T1000 A
Sony Corporation DTP-T1000 Development Tool DTP T1000 A
Users Manual
Development Tool Instruction manual SCE CONFIDENTIAL This manual contains safety precautions for the prevention of accidents, and instructions for the use and handling of this product. Read this manual carefully and use the product in a safe manner. After reading the manual, store it in an accessible location for future reference. DTP-T1000 A 2-515-713-11(1) WARNING WARNING To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. Use the supplied AC adaptor only. If you use other types, it may cause fire, electrical shocks or a malfunction. Laser specifications UMDTM Wave length: Power: Type: DVD-ROM Wave length: Power: Type: Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. FCC Radio-Frequency Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This This part of the manual would be modified equipment should be installed and operated with minimum distance 20 cm between the radiator and body (excluding for: extremities: hands, wrists and feet). "This equipment complies with FCC radiation 655-665 nm exposure limits set forth for an uncontrolled Owner’s Record environment. This max 0.28 mW and with serial numbers are located on the side of the equipment should be installedThe andmodel operated Semiconductor, continuous unit. Record the serial number in the space provided below. minimum Refer to and thesebody numbers distance 20 cm between the radiator This whenever you call for technical 640-660 nm (DVD) must no be co-located assistance at the number shown in "Contact information" on transmitter or operating in 775-805 nm (CD) back cover of this instruction manual. conjunction with any antennathe or transmitter" Model No. DTP-T1000 A max 0.3 mW (DVD) Serial No.______________ 0.23 mW (CD) Semiconductor, continuous For customers in the U.S.A. and Canada CAUTION The use of optical instruments with this product will increase eye hazard. As the laser beams used in the DVDROM and UMD™ drives are harmful to eyes, do not attempt to disassemble the cabinet. Refer servicing to qualified personnel only. For customers in Canada This Class A digital apparatus complies with Canadian ICES-003. The term “IC” before the equipment certification number only signifies that the Industry Canada technical specifications were met. Pour les utilisateurs au Canada Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Le terme “IC” avant le numéro d’homologation ne signifie seulement que les normes d’Industrie Canada ont été respectées. For customers in Europe CAUTION This label is located on the DVD-ROM laser protective housing inside the enclosure. The use of optical instruments with this product will increase eye hazard. As the laser beams used in the DVDROM and UMD™ drives are harmful to eyes, do not attempt to disassemble the cabinet. Refer servicing to qualified personnel only. For customers in the U.S.A. CAUTION Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial enviroment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. WARNING This label is located on the DVD-ROM laser protective housing inside the enclosure. WARNING This appliance is classified as a CLASS 1 LASER product. The CLASS 1 LASER product marking is located on the rear of the product. This equipment complies with EN55022 CLASS B and EN55024 for use in the following areas: residential, business, and light-industrial. This equipment has been tested and found to comply with the limits set out in the EMC Directive using a connection cable shorter than 3 metres. Audio and picture distortion may occur if this equipment is positioned in close proximity to any equipment emitting electromagnetic radiation. If this unit is affected by static electricity or burst-noise, it may not work correctly. Dit apparaat bevat een vast ingebouwde batterij die niet vervangen hoeft te worden tijdens de levensduur van het apparaat. Raadpleeg uw leverancier indien de batterij toch vervangen moet worden. De batterij mag alleen vervangen worden door vakbekwaam servicepersoneel. Gooi de batterij niet weg maar lever deze in als klein chemisch afval (KCA). Lever het apparaat aan het einde van de levensduur in voor recycling, de batterij zal dan op correcte wijze verwerkt worden. For customers in Korea 0412 WARNING Important safeguards For your protection, please read these safety instructions completely before operating the appliance, and keep this manual for future reference. Water and moisture Carefully observe all warnings, precautions and instructions on the appliance, or those described in the instruction manual and adhere to them. Do not use the powerline operated unit near water – for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement or near a swimming pool, etc. INSTALLATION Power cord protection USE Power sources This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of electrical power supplied to your home, consult your dealer or local power company. For those units designed to operate from battery power, or other sources, refer to the operating instructions. Overloading Do not overload wall outlets, extension cords or convenience receptacles beyond their capacity, since this can result in fire or electric shock. Liquid and foreign objects Never push objects of any kind into the unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit. Attachments Do not use attachments not recommended by the manufacturer, as they may cause hazards. Cleaning Unplug the unit from the wall outlet before cleaning or polishing it. Do not use liquid cleaners or aerosol cleaners. Use a cloth lightly dampened with water for cleaning the unit exterior. Important safeguards Route the power cord so that it is not likely to be walked on or pinched by items placed upon or against it, paying particular attention to the plugs, receptacles, and the point where the cord exits from the unit. Ventilation The slots and openings in the cabinet are provided for necessary ventilation. To ensure reliable operation of the unit, and to protect it from overheating, these slots and openings must never be blocked or covered. – Never cover the slots and openings with a cloth or other materials. – Never block the slots and openings by placing the unit on a bed, sofa, rug or other similar surface. Accessories Do not place the unit on an unstable cart, stand, bracket or table. The unit may fall, causing serious injury to a child or an adult, and serious damage to the unit. Use only a cart, stand, tripod, bracket, or table recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn. – Never place the unit in a confined space, such as a bookcase, or built-in cabinet, unless proper ventilation is provided. – Do not place the unit near or over a radiator or heat register, or where it is exposed to direct sunlight. Important safeguards SERVICE Damage requiring service Unplug the unit from the wall outlet and refer servicing to qualified service personnel under the following conditions: – When the power cord or plug is damaged or frayed. – If liquid has been spilled or objects have fallen onto the unit. – If the unit has been exposed to rain or water. – If the unit has been subject to strong physical shock by being dropped, or the cabinet has been damaged. – If the unit does not operate normally when following the instruction manual. Adjust only those controls that are specified in the instruction manual. Improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to normal operation. – When the unit exhibits a distinct change in performance – this indicates a need for service. Servicing Do not attempt to service the unit yourself as opening or removing the exterior casing may expose you to dangerous voltage or other hazards. Refer all servicing to an authorized service center. Refer to the contact information on the back cover to receive instructions on obtaining repair/ replacement services. Replacement parts When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer that have the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric shock, or other hazards. Safety check Upon completion of any service or repairs to the unit, ask the service technician to perform routine safety checks (as specified by the manufacturer) to determine that the unit is in safe operating condition. Important safeguards Table of contents WARNING ................................................................................. 2 Important safeguards ............................................................. 4 Precautions .............................................................................. 7 Chapter 1 Overview About this product .................................................................. 9 Part names and usage .......................................................... 10 System configuration example ............................................ 14 Chapter 2 Preparing to use the unit Connecting to a network ...................................................... 15 Unit or accessories necessary for connecting ....................... 15 Connection diagrams ............................................................ 15 Connecting peripherals ......................................................... 16 Setting up ............................................................................... 17 Information necessary for setup ........................................... 17 Preparing for setup ............................................................... 17 Turning on the unit ............................................................... 17 Confirming information settings .......................................... 18 Starting the Administration Tool .......................................... 18 Setting up .............................................................................. 19 Showing status ...................................................................... 24 Usage notice ......................................................................... 25 Chapter 3 Appendices Table of contents Troubleshooting .................................................................... 26 Specifications ........................................................................ 28 R&TTE Directive "Informal DoC" statement ....................... 29 Limitations of liability ........................................................... 30 Precautions Safety Use and handling • Do not use the unit or accessories outdoors. • Do not throw or drop the unit or accessories, or expose the devices to strong physical shock. • Do not place the unit or accessories on surfaces that are unstable, tilted or subject to vibration. • Do not expose the unit or accessories to high temperatures, high humidity or direct sunlight. • Do not block the vents. • Do not wrap the unit in cloth or similar materials. • Do not allow dust to build up on the unit. • Do not place the unit in locations of poor ventilation, such as small, enclosed areas, directly against a wall or on a thick carpet or bedding. • Do not expose the unit to dust, smoke or steam. • Do not allow liquid or small particles to get into the unit. • Do not put heavy objects on the unit. • Do not place anything in front of the disc tray. • Do not use damaged, reshaped or repaired discs. • Do not touch or insert foreign objects into the connectors of the unit or accessories. • Do not insert cords and cables at an angle. Doing so may damage the connector pins or create the risk of fire. • Do not set the unit other than in the vertical position. • If a spring or screw is provided to secure a cable connector, use the provided spring or screw to secure it. Take care to prevent making faulty connections. Precautions Overview This product has been designed with the highest concern for safety. However, any electrical device, if used improperly, has the potential for causing fire, electrical shock or personal injury. To help ensure accident-free operation, follow these guidelines. • Observe all warnings, precautions and instructions. • Stop use and unplug the AC power cord from the electrical outlet if the unit functions in an abnormal manner, or produces unusual sounds or smells. • Call the number listed on the back cover for technical assistance if the device does not operate properly. • Do not remove the unit’s exterior or disassemble the unit. The laser beam emitted from the lens of this unit may be harmful to the eyes. • Do not use the unit near water. • Stop using the unit immediately if you experience any of the following symptoms. If the condition persists, consult a doctor. – Lightheadedness, nausea or a sensation similar to motion sickness – Tired, uncomfortable or aching hands or arms – Tired, dry or aching eyes • Avoid looking at the screen for prolonged periods of time. • Listening to sound continuously for a long time with a high volume may adversely affect the ears. Be careful, especially when using headphones. Adjust the volume so that surrounding sounds can be heard. • Do not close the disc tray or disc cover in a way that could pinch your hand or fingers, as personal injury or damage to the unit could result. Precautions AC adaptor and AC power cord use Overview • To help ensure safe operation, during initial setup and regularly thereafter, inspect the AC adaptor and AC power cord. If damaged, stop use immediately and call the number on the back cover for assistance. • Do not use AC adaptors or AC power cords other than those provided or designated in the instruction manual. If the provided or designated AC adaptor or power cord is not used, electrical shock may result or the unit may not operate. • Do not modify or damage the AC power cord. • Do not place the AC adaptor between the unit and a wall or shelf. • Do not place heavy objects on the AC power cord. • Check that there is no dust or lint on the power plug before inserting into an electrical outlet. If the plug becomes dirty, wipe it off with a dry cloth before connecting. • When inserting the AC power cord into an electrical outlet, insert the plug straight into the electrical outlet and not at an angle. • Unplug the AC power cord from the electrical outlet before cleaning or moving the unit, or when you do not intend to use the unit for an extended period of time. When disconnecting, grasp the power cord by the plug and pull straight out of the electrical socket. Never pull by the cord and do not pull out at an angle. • Do not touch the plug of the AC power cord with wet hands. • Do not touch the power plug during an electrical storm. • Do not touch the unit or AC adaptor for extended periods of time while the unit is turned on, as extended contact may cause low-temperature burns. Cleaning • For safety reasons, before cleaning the unit or connected accessories, 1) turn off the unit, 2) disconnect the power plug for the unit from the electrical outlet. Moisture condensation • If the unit or disc is brought directly from a cold location to a warm one, moisture may condense on the lens inside the unit or on the disc. Should this occur, the unit may not operate properly. In this case, remove the disc and turn off and unplug the unit. Do not put the disc back in until the moisture evaporates (this may take several hours). If the unit still does not operate properly, obtain technical assistance using the contact information on the back cover. Precautions 1 Chapter About this product This unit is equipped with features for the development of PSPTM software. The unit can download software or data from a local area network, allowing for the efficient debugging, running and checking of programs. • PSPTM features are provided for efficient software development. • A built-in communication processor allows software, data etc. to be easily sent and received through the development PCs and networks. • A direct network connection can be established for easy installation and additions. Also, the load on development PCs can be reduced. • Two types of drives are built in: a UMDTM drive, and a DVD-ROM drive, which is used during development. A switch is used to select the desired drive. For proper operation, separate development software and a development PC are required. For details, contact technical support using the contact information on the back cover. About this product Overview Overview Part names and usage Unit front • Press the on/standby button and hold it down for three seconds. The power indicator will flash and then turn orange, at which point the power will be turned off (and the system will enter standby mode). • Remove the power plug from the electrical outlet after the power indicator turns a solid orange. If the plug is removed before the indicator turns orange, failure of the unit may result. UMD DRIVE SELECT DVD POWER Overview Turning the unit off (standby mode) SYSTEM INIT q; NETWORK INIT CONTROLLER qa GPO qd qs qf GPI ON OFF qg qh 1 On/standby button, power indicator This button turns the unit on and off. To turn on the unit Press the on/standby button while it is in standby mode. The power indicator flashes green as the power turns on. The indicator then turns solid green when the system is ready. The system status can be determined by the color and status of the power indicator. Flashing green The system is preparing to start up (flashes until the system becomes available after the on/standby button is pressed) Solid green The system is starting up (the unit can now be used) Flashing red During system initialization (auto-recovery) Solid red System initialization or update failure (indicates the need to initialize the system) Flashing orange During network initialization Solid orange Standby mode 10 Part names and usage 2 Disc cover The open button (3) is used to open the cover so that UMDTM can be inserted. When closing, press the middle of the upper edge of the disc cover. 3 Open button This button is used to open the disc cover (2). 4 Memory Stick DuoTM access indicator Turns orange while the unit is accessing a Memory Stick DuoTM or Memory Stick PRO DuoTM that has been inserted into the unit. 5 Memory Stick DuoTM slot This slot accepts Memory Stick DuoTM or Memory Stick PRO DuoTM media. 6 USB connector For connecting USB connectors (mini-B type). When the included controller is connected to the USB connector, the controller’s USB connector becomes functional. 7 Drive select button Switches between the UMDTM drive and the DVD-ROM drive. The selected drive is identified by the UMDTM/ DVD-ROM drive indicators (8). The drive select button (7) can be used only when the power indicator of the controller is not lit. 8 UMDTM/DVD-ROM drive indicator The indicator for the drive, UMDTM or DVDROM, turns orange to indicate which drive is selected. 9 Open/close button This button is used to open/close the DVD-ROM drive. Part names and usage qd Controller port Connects with the commander interface connector of the attached controller. qf GPO indicator These are eight indicators that are user-definable by PSPTM software developers. qg Headset connector A dedicated PSPTM headset remote controller or a commercially sold headset (with a stereo miniplug) can be connected here. qh GPI switch These are eight dip switches that are userdefinable by PSPTM software developers. Unit rear 1 Aerial For wireless LAN use. 2 Extension connector For use by service personnel only. 3 Serial port For use by service personnel only. Caution EXT Usage of this port may cause irreparable damage to the system. RF (EXT) q; 5 Network connector Connector for a network cable. Allows connection to a local area network. qa 6 VGA connector Connects to a device with a VGA IN connector. FOOT SW DC IN 19.5V AUDIO OUT 4 Foot switch connector Connects to the supplied foot switch. 7 AUDIO OUT connector Connects to a device with an AUDIO IN connector. 8 Vent fan Vent for internal fan used to cool unit. Be sure not to obstruct this vent, as doing so may cause a fire. Also, to prevent any hindrance to air flow, position the unit an adequate distance from walls. Part names and usage 11 Overview q; System initialise button While holding down this button, pressing the on/standby button (1) returns the communication processor software to the factory default initial state. qa Network initialise button While holding down this button, pressing the on/standby button (1) restores the factory default values for the IP address settings. qs DVD-ROM drive This drive accepts DVD-ROM discs. Use the open/close button (9) to insert and remove discs. Part names and usage 9 RF (extension) connector Connects to an access point using a coaxial cable. qa DC IN 19.5V connector For attaching the included AC adaptor. Overview q; Clamp For securing the aerial and AC adaptor to the unit. Controller front POWER q; qa qs HOLD HOME VOL SELECT START qd qf qg qh qjqkqlw; 1 LCD screen qa Strap holder 2 L button qs Left speaker 3 R button qd Right speaker 4 Up, down, left, right buttons qf Home button 5 △, ○, ×, □ buttons qg Volume - button 6 Power indicator qh Volume + button qj Display button 7 Hold indicator 8 Memory Stick Duo indicator TM access 9 WLAN access indicator q; Analog stick 12 Part names and usage qk Sound button ql Select button w; Start button Part names and usage Controller front Overview 1 IR port 2 USB connector Controller bottom 1 Left speaker 2 Right speaker Caution Do not cover or insert foreign objects into the speakers as doing so may result in damage to the controller. Controller left Controller right 1 WLAN switch 1 Power/hold switch Caution For this product, the debugger (dstdb) reset command cannot be used when the power/hold switch of the controller is in the hold position. Make sure that the controller's power/hold switch is not in the hold position when operating the debugger. Part names and usage 13 System configuration example The following accessories may be connected to the unit. To UMDTM drive USB device UMD To Memory Stick DuoTM slot DRIVE SELECT To USB connector DVD POWER Overview Unit front SYSTEM INIT To USB connector NETWORK INIT CONTROLLER To DVD-ROM drive GPO POWER HOLD HOME SELECT VOL START To controller port GPI ON OFF To headset connector Headset remote controller Caution When you connect or disconnect the controller, turn off power to the unit (keep it in standby mode). If the power is left on, it may result in damage to the unit or the controller. Unit rear Before connecting a cable, rotate the aerial in a clockwise direction, and raise it upright. If the cable is connected first, it may not be possible to rotate the aerial. EXT To RF (extension) connector RF (EXT) Foot switch To foot switch connector Wireless LAN access point To network connector FOOT SW Hub Monitor DC IN 19.5V To VGA connector AUDIO Speaker To AUDIO OUT connector 14 System configuration example OUT Development PC 2 Chapter Connecting to a network The unit Unit or accessories necessary for connecting The following devices and accessories are necessary in order to use this unit as a development machine: • Development Tool • Network cable • Hub • Development PC Connection diagrams Before connecting a cable, rotate the aerial in a clockwise direction, and raise it upright. If the cable is connected first, it may not be possible to rotate the aerial. Connecting to a network without a DHCP server You can build a local network with this unit and a development PC in the following manner. Hub Controller Development PC At this time, the following static IP addresses are automatically set for the unit: • IP address : 192.168.0.10 • Subnet mask : 255.255.255.0 Caution • The IP address and subnet mask settings are default factory settings. When the network settings for the unit are modified, these settings are also modified accordingly. • To modify the IP address, start up both the unit and the development PC, and configure their respective settings to support the network to which they are to be connected. After configuration, use a network cable to connect the unit and the development PC to a hub within the network in use. Refer to “Setting up” on page 17 for infomation on how to set up the unit. Connecting to a network 15 Preparing to use the unit Preparing to use the unit Connecting to a network Connecting to a network with a DHCP server When using the unit in Europe, Oceania and Korea Connect the unit and a development PC running the DHCP client software to a hub on the network. Install the supplied RFI filter on the network cable (unshielded twisted pair cable). Install the RFI filter near the main unit. Preparing to use the unit Network The unit Hub When installing the RFI filter on the cable, wind the cable once around the RFI filter, as shown below. There is a band supplied for use with the RFI filter. Use the band to attach the RFI filter to the cable. Fit the band to the cable, as shown below. Monitor Controller Development PCs cable Install near the unit In this case, the IP address and subnet mask settings will be obtained automatically when the unit is turned on. Depending on the settings of the DHCP server, other network settings, such as the DNS server and default gateway, may also be obtained. For details on which settings can be automatically obtained, contact your network administrator. Connecting peripherals Connect the unit to a hub using a network cable. Connect the hub to the development PC using a network cable. 16 Connecting to a network RFI filter Cut after fitting Band Setting up Information necessary for setup The following information is required for the setup of the unit. Connecting to a network with a DHCP server Turn on the development PC. Configure the DHCP server. When the IP address is automatically obtained by the DHCP server, the specific IP address allotted to a device is generally different each time the device is connected to the network. However, the use of the unit can be made more convenient by setting the same IP address to be allotted each time the device is connected. Contact your network administrator for details on how to set a static IP address. • DHCP server availability • IP address • Subnet mask • IP address of the default gateway Check with your network administrator about the structure of the network to which this unit will be connected. Preparing for setup Before setting up the unit, you need to configure your development PC. Connecting to a network without a DHCP server Turn on the development PC. Configure the TCP/IP settings of the development PC. Configure the TCP/IP settings as follows: • IP address of the development PC 192.168.0.2 • Subnet mask of the development PC 255.255.255.0 Activate the Web browser on the development PC, and configure it so that it does not use a proxy. Refer to the development PC’s instruction manual for details. Configure the development PC. Run the DHCP client software and configure it so that the development PC can obtain the IP address and other settings from the DHCP server. Refer to the instructions supplied with the development PC for details on how to configure the PC to run the software and obtain an IP address. Next, configure the development PC to run a Web browser. Turning on the unit After configuring the TCP/IP settings of the development PC, turn on the unit. Connect the AC power cord to the AC adaptor, then connect the AC adaptor to the unit. Insert the AC power cord into an electrical outlet. The power indicator turns orange, and the unit enters standby mode. Press the on/standby button. This turns on the unit and starts system initialization. During initialization, the power indicator flashes green. This indicator stops flashing when initialization is complete. Caution • When turning on the unit, be sure to use the supplied AC adaptor. • Do not operate the unit during initialization. Setting up 17 Preparing to use the unit Setting up Confirming information settings Login Log in with a user name and password. Confirm that the information below is displayed on the controller LCD: Preparing to use the unit • IP Address • Subnet mask • Broadcast address • IP address of the default gateway • Mac address • Host name Caution When you connect or disconnect the controller, turn off power to the unit (keep it in standby mode). If the power is left on, it may result in damage to the unit or the controller. Enter the user name and password. Starting the Administration Tool • user name: Administrator • password: Administrator * These are the factory default settings. Start up the Administration Tool on the development PC. The following section assumes use of the IP address 192.168.0.10 for the unit. Enter the user name and password as follows. To log in as the administrator, enter the “Administrator” user name and password as follows: When logged in as the administrator, all of the functions shown in the Administration Tools menu are active. Start the Web browser on the development PC. To log in as a user, enter the user name and password as follows: Type “http://192.168.0.10/” and press the “Enter” key. The language selection screen is displayed. • user name: User • password: User * These are the factory default settings. When logged in as a user, only the “Status Display” functions shown in the Administration Tools menu are active. The “Settings” functions cannot be used. Select the display language for the administration tool. The login screen is displayed. Select the language (for example English) here. 18 Setting up Click [OK]. Upon successfully logging in, the main screen of the Administration Tool is displayed. Setting up Setup These options allow the user to modify settings, update the software and shut down the unit. Change the administrator password User password Change the user password Date & time Configure the time and time zone Shutdown Reboot/Shutdown Network Configure the necessary network settings Access control Configure dsnet access control Reset of setting Initialize the selected settings Save & load Save settings, and synchronize the saved settings with this unit Update Update the system Restart of dsnetm Restart programs communicating with the host PC Self-diagnostic program Conduct a variety of tests Setting up Click on the items to the right of “Setup” to configure each setup. Preparing to use the unit Administrator password Online help You can view the Help for the Administration Tool. Administrator password Upon clicking “Administrator password”, the following screen is displayed. This screen is utilized to change the password used for administrator authentication. Show status The following unit settings can be displayed. Network Verify the network settings Softwave version Verify the version numbers of installed software packages Access control Display dsnet access control settings Enter the desired password in the “Password” and “Retype Password” fields. Click “Setting” to complete the configuration. Caution • For security purposes, be sure to change the default password. • The password must be a combination of both letters and numeric characters. Passwords consisting of all lowercase, all uppercase or all numeric characters are not allowed. • A password may be seven or eight characters long. Passwords fewer than seven characters long are not allowed. Also, if nine or more characters are entered, only the first eight characters are set as the password. • If an error is made in entering the password, or the values entered into the “Password” and “Retype password” fields do not match, an error message is displayed. If this occurs, enter the password again. Setting up 19 Setting up User password Date & time Upon clicking “User password”, the following screen is displayed. This screen is utilized to change the user password used to log in to the system. Upon clicking “Date & time”, the following screen is displayed. This screen is used to configure the date, time and time zone. Preparing to use the unit Enter the desired password in the “Password” and “Retype Password” fields. Click “Setting” to complete the configuration. Caution • For security purposes, be sure to change the default password. • The password must be a combination of both letters and numeric characters. Passwords consisting of all lowercase, all uppercase or all numeric characters are not allowed. • A password may be seven or eight characters long. Passwords fewer than seven characters long are not allowed. Also, if nine or more characters are entered, only the first eight characters are set as the password. • If an error is made in entering the password, or the values entered into the “Password” and “Retype password” fields do not match, an error message is displayed. If this occurs, enter the password again. Enter values for the year, month, day and time, and select the time zone. Click “Setting” to complete the configuration. Network Upon clicking “Network”, the following screen is displayed. This screen is used to change the method for obtaining an IP address and to change the values required for network configuration. If you want to change the network settings, enter the new network settings in the appropriate fields in this screen and then click “Setting confirmation”. The following confirmation screen is then displayed. 20 Setting up Setting up Update Upon clicking “Update”, the following screen is displayed. This screen is used to update the software required by the unit. Click “Setting” to begin processing the settings. After the configuration is set, the following screen is displayed. Caution Upon clicking “Setting confirmation” (see the step below), the versions of files that are already installed and the versions of the update files are checked to confirm whether the update files are more recent and to confirm the dependency relationships between files. This check is not performed if “No version checking” is selected. It is recommended that the default setting (“Check versions”) be used. Modify the network connection mode as needed, and access the URL displayed on the screen. Enter the path to the file to be updated, and click “Setting confirmation”. The following screen is displayed, and the contents of the update file are displayed. Setting up 21 Preparing to use the unit Place the files to be updated in the appropriate directories on the development PC, and click “Update”. The following screen appears. Setting up Verify the contents of the files, and click “Setting”. The installation will begin. If the contents are incorrect, click “Back” to make corrections. To save the unit’s settings on the development PC: Reset of setting This procedure may vary depending on the web browser used. For details, refer to the instructions for the web browser. Upon clicking “Reset of setting”, the following screen is displayed. This screen is used to restore the factory default network settings and administrator password. To configure the unit using settings saved on the development PC: Right-click on “psptool.conf” and then select “Save Target As” or “Save Link As”. Caution Preparing to use the unit Select the setting(s) to be initialized and click “Setting confirmation” to complete initialization. Check that the IP address defined in the development PC’s settings file is the same as the IP address assigned to the unit. If the IP address defined in the settings file and the unit’s IP address are different, use a text editor to change the IP address in the settings file of the development PC. Click “Browse” and select a file to use for configuring the unit. Click “Setting”. The settings will be saved on the unit, and the information will be modified. Save & load Access control Upon clicking “Save & load”, the following screen is displayed. This screen is used to save the settings and to synchronize the settings with the unit. Upon clicking “Access control”, the following screen is displayed. This screen is used to configure the PCs that will be allowed to access dsnet. “dsnet” is a program package for operating the unit. 22 Setting up Setting up To deactivate access control: Self-diagnostic program Upon clicking “Self-diagnostic program”, the following screen is displayed. This screen is used to perform a variety of self-diagnostic tests. Select “Disable”, and click “Setting”. This allows access from a PC that has been configured with any IP address. To activate access control: Select “Enable”, and click “Setting”. This allows access only from a PC that has been configured with one of the set IP addresses. Enter the IP address to be registered, and then click “Add IP address”. This registers the IP address to which access is permitted. Click on “Delete” next to an IP address that has already been registered to delete that address. Caution Enter an IP address using one of the following formats: • xxx.xxx.xxx.xxx (xxx = 0-255) • xxx.xxx.xxx.xxx/yy (xxx = 0-255, yy = 0-32) Preparing to use the unit Click on the process to be performed. The test will begin. Restart of dsnetm “dsnetm” is a program used to communicate between the TCP/IP sockets on the unit and a host PC. Upon clicking “Restart of dsnetm”, the following screen is displayed. Click “Restart” to restart dsnetm and display the restart status. After completing the restart, the following screen is displayed. Setting up 23 Setting up Showing status Click on the items to the right of “Show status” to verify the settings. Network Preparing to use the unit Upon clicking “Network”, the following screen is displayed. This screen allows the user to verify the unit's network settings. Shutdown Upon clicking “Shutdown”, the following screen is displayed. This screen is used to reboot or shut down the unit. Software version Upon clicking “Software version”, the following screen is displayed. This screen displays the versions of the software packages installed on the unit and allows the user to verify the unit's update history. To reboot: Select “Reboot” and click “Setting”. The reboot process will begin. It will take a few minutes to complete. To shutdown: 24 Select “Shutdown” and click “Setting”. This starts the termination process. The power will be automatically turned off and the unit will enter standby mode. The power can also be turned off (thereby putting the unit into standby mode) by pressing the on/standby button on the front of the unit. Setting up Setting up Access control Upon clicking “Access control”, the following screen is displayed. This screen lists the dsnet access control status and the IP addresses that have been granted access. This allows the user to verify this information. Preparing to use the unit Usage notice For this product, the debugger (dstdb) reset command cannot be used when the power/hold switch of the controller is in the hold position. Make sure that the controller’s power/hold switch is not in the hold position when operating the debugger. Setting up 25 Chapter Appendices Appendices Troubleshooting The power does not turn on. Check that the AC adaptor and the AC power cord are securely connected. The unit cannot be accessed over the network while in use. Check that the power indicator lights up in green to verify that the unit is turned on. Check that the network cable is securely connected. Check that the unit's settings have not been changed by other PCs. Contact your network administrator for assistance. When network settings are modified, the unit can no longer be accessed. The network setting may not be correct. Check the settings displayed on the connected controller. If no settings are displayed on the controller, disconnect and reconnect the power. The settings will then be displayed on the controller. About checking settings Check that you can access the currently connected network using the values for IP address/subnet mask that have been configured. For details, please consult your network administrator. To check whether the development computer and the unit are correctly communicating, start the ping command from the development computer. For details regarding the use of the ping command, see the “About the ping command” section below, or refer to the instruction manual supplied with the development computer. Also, by pressing the network initialise button, you can return the IP address settings to their factory default state. About the ping command If your development PC’s operating system supports the “ping” command, enter the ping command as shown below. # ping (the IP address of the unit) 26 Troubleshooting Troubleshooting When network communications are functioning, you will see information like the following at a fixed interval: PING 192.168.0.10 (192.168.0.10): 56(84) data bytes 64 bytes from 192.168.0.10: icmp_seq=0 ttl=64 time=0.1 ms 64 bytes from 192.168.0.10: icmp_seq=1 ttl=64 time=0.1 ms 64 bytes from 192.168.0.10: icmp_seq=2 ttl=64 time=0.1 ms (continued below) • When the indicator flashes orange: The communications are functioning properly. • When the indicator is not turned on: The communications are not functioning properly. This may be due to disconnected cables, damaged connections, or a unit malfunction. The unit cannot be accessed, even though five minutes have elapsed since it was turned on. Check that the power indicator lights up in green. If so, there may be a problem with the network cable or the connected hub. Change the network cable or hub, or contact your network administrator for assistance. Troubleshooting 27 Appendices When network communications are not functioning, the information will stop after the following: PING 192.168.0.10 (192.168.0.10): 56 data bytes If the display appears as shown above, check the following items: • Is the network cable securely connected to the network connector on the unit? • Is the network cable securely connected to the hub? • Is the network cable securely connected to the development PC? • Do the network settings of the development PC match those of the unit? After checking the above items, start the ping command from the development PC. Then check the indicator next to the network connector on the rear of the unit. Specifications Main unit (DTP-T1000 A) Appendices Compatible discs CD-ROM / CD-R / DVD-ROM / DVD-R / UMDTM Power Input voltage DC IN 19.5V Power consumption 5A Operating environment Operating temperature 10°C - 35°C Operating humidity 30% - 70% (not condensed) Dimensions (excluding protrusions) Development tool 100 x 280 x 298 mm Controller 170 x 74 x 23 mm (w/h/d) Weight Development tool 5.0 kg or less Controller 190 ± 30 g (excluding cables) Processor Dedicated processor (max 333 MHz) Built-in memory 64 MB (fixed) Built-in peripherals Communication processor (300 MHz) External interfaces USB connector x 1 Memory Stick DuoTM slot x 1 Controller connector x 1 Foot switch connector x 1 Headset connector x 1 RF (extension) connector x 1 Aerial x 1 (For wireless LAN IEEE 802.11b) Network connector x 1 (100 BASE-TX/10 BASE-T) VGA connector x 1 (Analog RGB, D-SUB, 15-pin) AUDIO OUT (audio output) connector x 1 (RCA pin) Dedicated connector for servicing x 1 (For use by service personnel only.) Extension connector x 1 (Devices other than those designated cannot be used.) Wireless LAN channels USA and Canada Europe 1-11 ch. 1-13 ch. AC adaptor (DTP-H100) Power Input voltage AC Output voltage DC Rated frequency Power consumption 100 - 240V (±10%) 19.5 V 50/60Hz (±2%) 1.6A (100V), 0.7A (240V) External dimensions 160 x 38 x 80 mm (w/h/d) Weight Approx. 570 g Supplied accessories Instruction manual x 1 AC power cord for use in Oceania x 1 AC power cord for use in Europe x 1 AC power cord for use in Korea x 1 AC power cord for use in the UK x 1 AC power cord for use in the USA and Canada x 1 AC adaptor x 1 Controller x 1 (With controller-interface cable [1.5 m]) Foot switch [1.9 m] x 1 RFI filter for use in Europe, Oceania and Korea x 1 Fitting band for use in Europe, Oceania and Korea x 1 Design and specifications are subject to change without notice. 28 Specifications R&TTE Directive "Informal DoC" statement For customers in Europe "Informal DoC" Dutch Undertegnede Sony Computer Entertainment Inc. erklærer herved, at følgende udstyr DTP-T1000 overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. For yderligere information gå ind på følgende hjemmeside: http://www.compliance.sony.de/ Dutch Hierbij verklaart Sony Computer Entertainment Inc. dat het toestel DTP-T1000 in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Nadere informatie kunt u vinden op: http://www.compliance.sony.de/ English Hereby, Sony Computer Entertainment Inc. declares that this DTP-T1000 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. For details, please access the following URL: http://www.compliance.sony.de/ Finnish Sony Computer Entertainment Inc. vakuuttaa täten että DTP-T1000 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Halutessasi lisätietoja, käy osoitteessa: http://www.compliance.sony.de/ French Par la présente Sony Computer Entertainment Inc. déclare que l’appareil DTP-T1000 est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Pour toute information complémentaire, veuillez consulter l’URL suivante: http://www.compliance.sony.de/ German Hiermit erklärt Sony Computer Entertainment Inc. dass sich dieser/diese/dieses DTP-T1000 in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Weitere Informationen erhältlich unter: http://www.compliance.sony.de/ Greek Με την παρούσα η Sony Computer Entertainment Inc. δηλώνει τι DTP-T1000 συµµορφώνεται προς της ουσιώδεις απαιτήσεις και της λοιπές σχετικές διατάξεις της οδηγίας 1999/5/EK. Για λεπτοµέρειες παρακαλούµε πως ελένξετε την ακλουθη σελίδα του διαδικτύου: http://www.compliance.sony.de/ Italian Con la presente Sony Computer Entertainment Inc. dichiara che questo (DTP-T1000) è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Per ulteriori dettagli, si prega di consultare il seguente URL: http://www.compliance.sony.de/ Portuguese Sony Computer Entertainment Inc. declara que este DTP-T1000 está conforme com os requisitos essenciais e outras provisões da Directiva 1999/5/CE. Para mais informacoes, por favor consulte a seguinte URL: http://www.compliance.sony.de/ Spanish Por medio de la presente Sony Computer Entertainment Inc. declara que el (DTP-T1000) cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Para mayor información, por favor consulte el siguiente URL: http://www.compliance.sony.de/ Swedish Härmed intygar Sony Computer Entertainment Inc. att denna DTP-T1000 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. För ytterligare information gå in på följande hemsida: http://www.compliance.sony.de/ R&TTE Directive "Informal DoC" statement 29 Appendices Language Limitations of liability This product is supplied pursuant to and subject to the terms of the tool loan agreement with Sony Computer Entertainment Inc. or its affiliates. Other than as expressly set forth by SCEI and/or any of its affiliates, except to the extent prohibited by applicable laws, SCEI and/or any of its affiliates shall not be liable for any damages, including special, incidental or consequential damages, or fees arising out of the use or inability to use this product. Appendices 30 Limitations of liability Appendices 31 This product may fall within the scope of national export control legislation. You must comply fully with the requirements of such legislation and of all other applicable laws of any jurisdiction in relation to this product. Contact information: Japan 3rd Party Relations Division Sony Computer Entertainment Inc. 7-1-1 Akasaka, Minato-ku, Tokyo 107-0052 Japan TEL: +81-3-6438-8635 (direct) Korea Developer Support Sony Computer Entertainment Korea Inc. 14Fl. Koosan Tower, 3250, Bangbae2-Dong Seocho-Gu, Seoul, #137-853 Korea E-mail: ps2_support@scek.co.kr TEL: +82-2-6230-3596 (direct) United Kingdom (Europe) Technology Group Sony Computer Entertainment Europe 25 Golden Square London W1F 9LD UK TEL: +44-207859-5777 (direct) http://www.scee.sony.co.uk/ USA Developer Support Sony Computer Entertainment America 919 East Hillsdale Boulevard, 2nd Floor Foster City, CA 94404-2175 USA TEL: +1-650-655-5566 (direct) FAX: +1-650-655-5511 (direct) Without obtaining the consent of the owner, no part of the content of this document may be copied, pursuant to the provisions of the Copyright Act. “ ” is a registered trademark and “ Entertainment Inc. ” and “UMD” are trademarks of Sony Computer “SONY” and “ ” are registered trademarks and “Memory Stick Duo”, “Memory Stick PRO Duo” and “ are trademarks of Sony Corporation. © 2004 Sony Computer Entertainment Inc. All rights reserved. ” Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Page Count : 32 Page Mode : UseOutlines Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0746c770-762e-4586-aed0-70d33d801d14 Producer : Acrobat Distiller 5.0.1 for Macintosh Create Date : 2004:11:08 09:20:18Z Modify Date : 2004:11:26 22:02:53+09:00 Metadata Date : 2004:11:26 22:02:53+09:00 Creator Tool : PageMaker 6.5J Document ID : uuid:e46d1843-9f60-4d8f-9435-306368ca03a7 Format : application/pdf Creator : Sony Computer Entertainment Inc. Title : DTP-T1000 A Author : Sony Computer Entertainment Inc.EXIF Metadata provided by EXIF.tools