Operating Instructions1Wireless Access PointsForewordWe are pleased to welcome you as a new Sophos Access Point customer.These operating instructions will help you install and configure the access point and provide technical specifications of all Sophos access point models. In addition, please also see the following documents that contain useful information on safety, regulatory compliance, and configuration options: Ì Sophos Access Points Safety Instructions and Regulatory Information Ì Sophos UTM Administration Guide: Configuring the UTM hardware and software applianceThe instructions must be read carefully prior to using the device and should be kept in a safe place. You may download all user manuals and additional documentation from the Sophos Knowledgebase at http://www.sophos.com/en-us/support/knowledgebase.aspx.IntroductionUTM Wireless Protection simplifies the operation of secure and reliable wireless networks. It combines affordable and configuration-less access points through a built-in wireless controller in the in Sophos UTM. The wireless controller itself centrally manages all wireless access points; all you need to do is plug in the device anywhere in your network. The access point will find the controller, fetch its configuration and become operable within seconds. In addition, it easily provides wireless guest Internet access during the initial setup, unless you explicitly deny automatic configuration.InstallationPreliminary stepsPlease update your UTM appliance to the latest version available. Note that you also need a valid UTM Wireless Protection subscription to operate the Sophos Access Points.Connect the access point to the internal networkDecide where you would prefer to place the access point, and put the access point in that location. For mounting instructions, see below. Now connect the access point to your internal network by plugging in the network cable to the access point’s RJ45 or LAN (PoE) Ethernet interface, respectively.
Operating Instructions2Wireless Access PointsConnect the access point to the power supplyThe AP 15, AP 15C, AP 55, AP 55C, AP 100, AP 100C, and AP 100X can be powered directly through the Power-over-Ethernet-injector. Note that it is also possible to power them by a PoE-compliant switch. For more information on PoE-injectors, see below.Connect the AP 15 to the power supply. Please use the power supply from the scope of supply. Note that the AP 15 can also be operated through a PoE-injector or PoE-compliant switch.Start the communication between the access point and the UTM applianceWhen connected to the network, the access point will try to receive an IP address via DHCP. Therefore, you need either the UTM appliance (with a DHCP server enabled and listening on the interface the access point is connected to) or any other DHCP server to provide an IP address for the access point. After successfully receiving an IP address, the access point will communicate with the UTM appliance. For this to happen, the UTM appliance needs to be put in the upstream of the access points, either being the default gateway of the access points (which was provided by the DHCP service) or on the default route (most likely your route to the Internet).Please note that the actual Internet access is not necessary to use UTM Wireless Protection. While waiting for DHCP and searching for the UTM appliance, the access point’s power LED will blink slowly.Enable UTM Wireless Protection on the UTM applianceIn WebAdmin, navigate to the Wireless Protection menu entry. On the Global Settings tab, click the Enable button. When enabling Wireless Protection for the first time, the Initial Setup frame will appear. It shows the configuration which will be created: A separate Wireless “Guest” network using WPA2 personal with DHCP for wireless clients, which will be allowed to use DNS on the UTM appliance and the “Web Surfing” service.The pre-shared key is auto-generated and will only be shown in this section. This configuration is intended as a template, you can edit the settings at any time on the Wireless Protection > Wireless Networks tab. You can also skip the initial setup by ticking the checkbox on the bottom of the section.
Operating Instructions3Wireless Access PointsAccepting the access pointThe UTM appliance will start to communicate with the access point and they will show up as “Pending” on the Wireless Protection > Access Points tab in WebAdmin. The ID of the Access Points, shown in square brackets, is also printed on the bottom of the device. It can be used to distinguish the access point. By clicking the Accept button, you are given the option to select the channel this access point will transmit on. When leaving the channel setting on “Auto”, the access point will use the least used channel.We also suggest to give the access point a meaningful location (e.g., “Meeting Room”) as this will ease handling multiple access points. After clicking the Save button, the access points will reboot. Upon reconnect, the access point will check if a more recent firmware is available. If so, they will automatically perform a firmware update. During the firmware update, the access point’s power LED will blink rapidly.Important note: Do not unplug the power while the firmware is updating. Otherwise the access point will be rendered inoperable and must be returned to the reseller.The access point will then reboot to complete the firmware update. If no new firmware is available, the access point is operational and appears as “Active” in WebAdmin.Country code selection usage (WLAN devices)Note: According to FCC regulations, all WLAN devices marketed and sold in the U.S. must be restricted to U.S. channels only. Therefore, the country code selection is applicable to non-U.S. models only. So changing the country setting of any Sophos AP sold in the U.S. will not modify authorized parameters such as RF channels, which means that the Access Point will always operate in U.S. authorized channels.
Operating Instructions4Wireless Access PointsAP 15Scope of supplyImportant note: Sophos AP 15 requires Sophos UTM V 9.207 to be installed.10/100/1000 Base-TX PowerMounting instructionsThe Sophos AP 15 can be mounted on the wall. Screws are included in delivery. Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfaceSophos AP 15 2 screws and dowelsSecurity Notes Power supply Ethernet cable2 Detachable dipole antenna
Operating Instructions5Wireless Access PointsTechnical specificationsSophos AP 15Chassis Plastic housing, whiteMaximum throughput 300 Mbit/sLAN interfaces 1 x 10/100/1000 Base-TXSupported WLAN standards 802.11 b/g/n 2.4 GHzAntenna 2 x detachable dipole antenna (2 dBi) Connector type: RP-SMAFrequencies / channels ETSI FCC2.412–2.472 GHz (Channels 1-13) 2.412-2.462 GHz (channels 1-11)Power supply 12 Vdc / 1 APower consumption 2.5 W (max.)Power-over-Ethernet 802.3afDimensions W x H x D 194 x 32 x 115 mmWeight 260gTemperature range Operating: 0°C to 45°C Storage: -20°C to 60°CHumidity (non-condensing) 0% to 90%Mounting Desktop / wallSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)Number of supported SSIDs 8Regulatory compliance CE FCCRadio: EN 300328 CFR 47, Part 15 Subpart CEMC: EN 301489-1, EN 301489-17 CFR 47, Part 15 Subpart BEMF: EN 50385 FCC 1.1310, IEEE C95.1Safety: EN 60950-1 N/a
Operating Instructions6Wireless Access PointsAP 15 Mounting templateDo not shrink to fit when printing12 cm (4,72 in)
Operating Instructions7Wireless Access PointsAP 15CScope of supplyImportant note: Sophos AP 15C requires Sophos UTM V 9.400 to be installed.Mounting instructionsThe Sophos AP 15C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket.1.   Mount the bracket on the ceiling Use the screws and anchors from the scope of supply.2.  Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop.Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfacePower1 x 10/100/1000 Base-TX ConsoleSecurity Notes Ethernet cableSophos AP 15C Mounting bracket Screws and T-rail clipsPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions8Wireless Access PointsTechnical specificationsSophos AP 15CChassis Plastic, whitePhysical security Kensington lockMaximum theoretical throughput 300 Mbps (5GHz / 802.11an) + 300 Mbps (2.4GHz / 802.11n)LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/nAntenna 4 x internal antennasFrequencies / channels ETSI2.412-2.472GHz (channels 1-13)  5.180-5.240GHz (channels 36-48)FCC2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48)U-NII-3: 5.745-5.825GHz (channels 149-165)MIC2.412-2.472GHz (channels 1-13) W52: 5.180-5.240GHz (channels 36-48)Power supply 12 Vdc / 1 APower consumption 7 W (max.)Power-over-Ethernet 802.3af/atDiameter x H 176 x 29.86mmWeight 265gTemperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90%Mounting CeilingSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)  Number of supported SSIDs 8Regulatory compliance CB, CE, UL, FCC, IC, MIC, VCCI, RCM
Operating Instructions9Wireless Access PointsAP 55Scope of supplyImportant note: Sophos AP 55 requires Sophos UTM V 9.308 to be installed.Mounting instructionsThe Sophos AP 55 can be mounted on the wall. A mounting kit is included in delivery.Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfaceConsole Console access for debugging purposesUSB Currently not used; reserved for future useConsoleUSB10/100/1000 Base-TXPowerSophos AP 55 4 screws, dowels and metal platesSecurity Notes Ethernet cable2 Detachable dipole antennaPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions10Wireless Access PointsTechnical specificationsSophos AP 55Chassis Plastic housing, whitePhysical security Kensington lockMaximum theoretical throughput 867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n)LAN interfaces 1 x 10/100/1000 Base-TXSupported WLAN standards 802.11a/b/g/n/acAntenna 2 x detachable dipole antenna (2 dBi) Connector type: RP-SMAFrequencies / channels ETSI2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1:  5.180-5.320GHz (channels 36-64)RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48)U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 4 APower consumption 11 W (max.)Power-over-Ethernet 802.3atDimensions W x H x D 183 x 36 x 183 mmWeight 500gTemperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90%Mounting Desktop / wallSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)Number of supported SSIDs 8 per radio (16 in total)Regulatory compliance CE FCCRadio: EN 300 328, EN 301 893  CFR 47, Part 15 Subpart C, EEMC: EN 301 489-1, EN 301 489-17  CFR 47, Part 15 Subpart BEMF: EN 50385 FCC 1.1310, IEEE C95.1Safety: EN 60950-1 N/a
Operating Instructions11Wireless Access PointsAP 55CScope of supplyImportant note: Sophos AP 55C requires Sophos UTM V 9.308 to be installed.Mounting instructionsThe Sophos AP 55C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket.1.   Mount the bracket on the ceiling Use the screws and anchors from the scope of supply.2.  Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop.Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfacePower1 x 10/100/1000 Base-TX Security Notes Ethernet cableSophos AP 55C Mounting bracket Screws and  T-rail clipsPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions12Wireless Access PointsTechnical specificationsSophos AP 55CChassis Top enclosure: plastic, white; bottom enclosure: metal, white Physical security Kensington lockMaximum theoretical throughput 867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n)LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/acAntenna 4 x internal antennasFrequencies / channels ETSI2.412–2.472 GHz (Channels 1-13)  RLAN sub-band 1: 5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140)  FCC2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165)  Power supply 12 Vdc / 1.5 APower consumption 13 W (max.)Power-over-Ethernet 802.3atDiameter x H 200 x 37mmWeight 630gTemperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90%Mounting CeilingSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)Number of supported SSIDs 8 per radio (16 in total)Regulatory compliance CE FCCRadio: EN 300 328, EN 301 893  CFR 47, Part 15 Subpart C, EEMC: EN 301 489-1, EN 301 489-17  CFR 47, Part 15 Subpart BEMF: EN 50385 FCC 1.1310, IEEE C95.1Safety: EN 60950-1 UL-60950-1, UL-2043 (plenum rated)
Operating Instructions13Wireless Access PointsAP 100Scope of supplyImportant note: Sophos AP 100 requires Sophos UTM V 9.207 to be installed.Mounting instructionsThe Sophos AP 100 can be mounted on the wall. A mounting kit is included in delivery.Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfaceConsole Console access for debugging purposesUSB Currently not used; reserved for future useConsoleUSB10/100/1000 Base-TXPowerSophos AP 100 4 screws, dowels and metal platesSecurity Notes Ethernet cable3 Detachable dipole antennaPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions14Wireless Access PointsTechnical specificationsSophos AP 100Chassis Plastic housing, whitePhysical security Kensington lockMaximum theoretical throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n)LAN interfaces 1 x 10/100/1000 Base-TXSupported WLAN standards 802.11a/b/g/n/acAntenna 3 x detachable dipole antenna (2 dBi) Connector type: RP-SMAFrequencies / channels ETSI2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1:  5.180-5.320GHz (channels 36-64)RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48)U-NII-2: 5.260-5.320GHz (channels 52-64)U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140)U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 4 APower consumption 13 W (max.)Power-over-Ethernet 802.3atDimensions W x H x D 183 x 36 x 183 mmWeight 505gTemperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90%Mounting Desktop / wallSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)Number of supported SSIDs 8 per radio (16 in total)Regulatory compliance CE FCCRadio: EN 300 328, EN 301 893  CFR 47, Part 15 Subpart C, EEMC: EN 301 489-1, EN 301 489-17  CFR 47, Part 15 Subpart BEMF: EN 50385 FCC 1.1310, IEEE C95.1Safety: EN 60950-1 N/a
Operating Instructions15Wireless Access PointsAP 100CScope of supplyImportant note: Sophos AP 100C requires Sophos UTM V 9.308 to be installed.Mounting instructionsThe Sophos AP 100C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket.1.   Mount the bracket on the ceiling Use the screws and anchors from the scope of supply.2.  Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop.Controls LEDGreen - blinking slowly AP is bootingGreen - blinking rapidly Network connectivityOrange - blinking slowly No connection to the Sophos UTMOrange - blinking rapidly Firmware updateInterfaces and buttons12V DC-IN PowerLAN (PoE) 10/100/1000 Base-TX interfacePower1 x 10/100/1000 Base-TX Security Notes Ethernet cableSophos AP 100C Mounting bracket Screws and  T-rail clipsPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions16Wireless Access PointsTechnical specificationsSophos AP 100CChassis Top enclosure: plastic, white; bottom enclosure: metal, white Physical security Kensington lockMaximum theoretical throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/acAntenna 6 x internal antennas Frequencies / channels ETSI2.412–2.472 GHz (Channels 1-13)  RLAN sub-band 1  5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140)   FCC2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165)  Power supply 12 Vdc / 1.5 APower consumption 15 W (max.)Power-over-Ethernet 802.3atDiameter x H 200 x 37mmWeight 630gTemperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90%Mounting CeilingSupported security standards WPA/WPA2, WEP, 802.1X (RADIUS)Number of supported SSIDs 8 per radio (16 in total)Regulatory compliance CE FCCRadio: EN 300 328, EN 301 893  CFR 47, Part 15 Subpart C, EEMC: EN 301 489-1, EN 301 489-17  CFR 47, Part 15 Subpart BEMF: EN 50385 FCC 1.1310, IEEE C95.1Safety: EN 60950-1 UL-60950-1, UL-2043 (plenum rated)
Operating Instructions17Wireless Access PointsAP 100XScope of supplyImportant note: Sophos AP 100X requires Sophos UTM V 9.308 to be installed.Mounting instructionsThe Sophos AP 100X can be mounted on a pole. A mounting kit is included in delivery.Warning: The equipment has a separate protective earthing terminal on the chassis that must be permanently connected to earth ground to adequately ground the chassis and protect the operator from electrical hazards.Caution: Before equipment installation begins, ensure that a service personnel has attached an appropriate grounding lug to the grounding cable that you supply.Power installation must be performed with qualified electrician and followed with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1.To connect earth ground to Unit: ÌConnect one end of the grounding cable to a proper earth ground. ÌPlace the grounding lug attached to the grounding cable over the protective earthing terminal. ÌSecure the grounding lug to the protective earthing terminal with the washers and screws. ÌDress the grounding cable and ensure that it does not touch or block access to other components.Warning: At first before powered on, connect the frame of the unit to earth. For earthing wire, green-and-yellow insulation is required and the cross-sectional area of the conductor must be more than 0.75mm2 or 18 AWG.Controls LEDPower (Green) - continuously on Power onWLAN (Green) - blinking rapidly WLAN activityWLAN (Green) - blinking regularly Firmware updateLAN (Green) - blinking rapidly Network connectivityInterfaces and buttonsLAN (PoE) 10/100/1000 Base-TX interfaceReset Currently not supported10/100/1000 Base-TXConnect a ground cable from the outdoor unit to an appropriate grounding point.Sophos AP 100X Security Notes 6 antenna Ethernet cable Grounding wire1 wall mount plate 4 wood screws and wood/gyprock plug, 4 M6 screws and washers 1 M25  cable gland2 metal strapsPower-over-Ethernet (PoE)  injector + power cord
Operating Instructions18Wireless Access PointsTechnical specificationsSophos AP 100XMounting Wall / PoleChassis Metal housing, whiteIP Code 67Maximum throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n)Multiple SSIDs 8 per radio, 16 in totalNumber of radios 2MIMO capabilities 3x3:3LAN interfaces 1 x 10/100/1000 Base-TXAntenna 6 x external dipole antenna Connector type: N-TypeAntenna gain 4 dBi @ 2.4GHz, 6 dBi @5GHzSupported WLAN standards 802.11a/b/g/n/acFrequencies / channels ETSI2.412-2.472GHz (channels 1-13) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140)FCC2.412-2.462GHz (channels 1-11) U-NII-2: 5.260-5.320GHz (channels 52-64)U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140)U-NII-3: 5.745-5.825GHz (channels 149-165)Dimensions W x H x D 255 x 225 x 90 mmWeight 2.5kgPower supply PoE onlyPower consumption 15 W (max.)Power-over-Ethernet 802.3atTemperature range Operation: -20°C to 60°C Storage: -30°C to 60°C Humidity (non-condensing) Operation: 0% to 90% Storage: 0% to 95% Regulatory compliance CE FCC ULRadio: EN 300 328, EN 301 893  CFR 47, Part 15 Subpart C Section 15.247 and Subpart E Section 15.407N/aEMC: EN 301489-1,  EN 301489-17CFR 47, Part 15 Subpart BN/aEMF: EN 62311 CFR 47, Part 2 (Section 2.1091)N/aSafety: EN 60950-22 N/a UL 60950-22
Operating Instructions19Wireless Access PointsPower-over-Ethernet injectorOptionally included with AP 15C, AP 55, AP 55C, AP 100, AP 100C and AP 100XThe PoE injector converts alternating current (AC) to direct current (DC), which is then provided over the Ethernet cable to power the Sophos Access Points.InstallationWarning: Do not use crossover cable between the PoE injector’s output port and the access point.Before placing the PoE injector, please pay attention to the following safety instructions: Ì Do not cover the PoE injector or block the airflow to the PoE with any foreign objects. Keep the PoE away from excessive heat and humidity and free from vibration and dust. Ì Ensure that the cable length from Ethernet network source to the access point does not exceed 100 m  (330 ft). The PoE is not a repeater and does not amplify the Ethernet data signal.To install the PoE injector, proceed as follows:1.   Connect an Ethernet cable to the Data & Power Out interface.2.  Connect the other end of this Ethernet cable to the Ethernet interface of the access point.3.  Connect an Ethernet cable to the Data In interface.4.  Connect the other end of this Ethernet cable to your network switch.5.  Connect the AC power cord from the scope of supply to the PoE injector.6.  Connect the AC power cable to an AC outlet  (100-240 VAC).ControlsLED displayOff Power offYellow continuously Power onGreen continuously A remote terminal is connectedGreen blinking Overload state or short-circuit InterfacesInput (Data In) 1 x 10/100/1000 Base-TXOutput (Data & Power Out) 1 x 10/100/1000 Base TX, plus 55 VDCLEDData & Power OutData InPower
Operating InstructionsTechnical specificationsChassis Plastic housingInput power AC Input Voltage: 100 to 240 VACAC Input Current: 0.8A @ 100-240 VACAC Frequency: 50 to 60 HzPower-over-Ethernet output (max.) Output power voltage: 55 VDCOutput power: 30 WSupported PoE standard 802.3at compliantWeight 200gDimensions W x H x D 1 x 10/100/1000 Base TX, plus 55 VDCMounting Desktop / wallTemperature 0°C to 40°C (operating)-20°C to 70°C (storage)Humidity (non-condensing) 10% to 90%Regulatory compliance CE, FCC, VCCI, UL, GS, RoHS, WEEEUnited Kingdom and Worldwide SalesTel: +44 (0)8447 671131Email: sales@sophos.comNorth American SalesToll Free: 1-866-866-2802Email: nasales@sophos.comAustralia and New Zealand SalesTel: +61 2 9409 9100Email: sales@sophos.com.auAsia SalesTel: +65 62244168Email: salesasia@sophos.comOxford, UK | Boston, USA© Copyright 2015. Sophos Ltd. All rights reserved.Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UKSophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are trademarks or registered trademarks of their respective owners.2015-12-16 OINA (DD-2252)