Sophos AP15C Sophos wireless Access Point User Manual
Sophos Ltd Sophos wireless Access Point Users Manual
Sophos >
Contents
- 1. Safety Instructions Indoor
- 2. Users Manual
Users Manual
Operating Instructions Sophos Access Points Operating Instructions Foreword We are pleased to welcome you as a new Sophos Access Point customer. These operating instructions will help you install and configure the access point and provide technical specifications of all Sophos access point models. In addition, please also see the following documents that contain useful information on safety, regulatory compliance, and configuration options: ÌÌ Sophos Access Points Safety Instructions and Regulatory Information ÌÌ Sophos UTM Administration Guide: Configuring the UTM hardware and software appliance The instructions must be read carefully prior to using the device and should be kept in a safe place. You may download all user manuals and additional documentation from the Sophos Knowledgebase at http://www.sophos.com/en-us/support/ knowledgebase.aspx. Introduction UTM Wireless Protection simplifies the operation of secure and reliable wireless networks. It combines affordable and configuration-less access points through a builtin wireless controller in the in Sophos UTM. The wireless controller itself centrally manages all wireless access points; all you need to do is plug in the device anywhere in your network. The access point will find the controller, fetch its configuration and become operable within seconds. In addition, it easily provides wireless guest Internet access during the initial setup, unless you explicitly deny automatic configuration. Installation Preliminary steps Please update your UTM appliance to the latest version available. Note that you also need a valid UTM Wireless Protection subscription to operate the Sophos Access Points. Connect the access point to the internal network Decide where you would prefer to place the access point, and put the access point in that location. For mounting instructions, see below. Now connect the access point to your internal network by plugging in the network cable to the access point’s RJ45 or LAN (PoE) Ethernet interface, respectively. Wireless Access Points Operating Instructions Connect the access point to the power supply The AP 15, AP 15C, AP 55, AP 55C, AP 100, AP 100C, and AP 100X can be powered directly through the Power-over-Ethernet-injector. Note that it is also possible to power them by a PoE-compliant switch. For more information on PoE-injectors, see below. Connect the AP 15 to the power supply. Please use the power supply from the scope of supply. Note that the AP 15 can also be operated through a PoE-injector or PoEcompliant switch. Start the communication between the access point and the UTM appliance When connected to the network, the access point will try to receive an IP address via DHCP. Therefore, you need either the UTM appliance (with a DHCP server enabled and listening on the interface the access point is connected to) or any other DHCP server to provide an IP address for the access point. After successfully receiving an IP address, the access point will communicate with the UTM appliance. For this to happen, the UTM appliance needs to be put in the upstream of the access points, either being the default gateway of the access points (which was provided by the DHCP service) or on the default route (most likely your route to the Internet). Please note that the actual Internet access is not necessary to use UTM Wireless Protection. While waiting for DHCP and searching for the UTM appliance, the access point’s power LED will blink slowly. Enable UTM Wireless Protection on the UTM appliance In WebAdmin, navigate to the Wireless Protection menu entry. On the Global Settings tab, click the Enable button. When enabling Wireless Protection for the first time, the Initial Setup frame will appear. It shows the configuration which will be created: A separate Wireless “Guest” network using WPA2 personal with DHCP for wireless clients, which will be allowed to use DNS on the UTM appliance and the “Web Surfing” service. The pre-shared key is auto-generated and will only be shown in this section. This configuration is intended as a template, you can edit the settings at any time on the Wireless Protection > Wireless Networks tab. You can also skip the initial setup by ticking the checkbox on the bottom of the section. Wireless Access Points Operating Instructions Accepting the access point The UTM appliance will start to communicate with the access point and they will show up as “Pending” on the Wireless Protection > Access Points tab in WebAdmin. The ID of the Access Points, shown in square brackets, is also printed on the bottom of the device. It can be used to distinguish the access point. By clicking the Accept button, you are given the option to select the channel this access point will transmit on. When leaving the channel setting on “Auto”, the access point will use the least used channel. We also suggest to give the access point a meaningful location (e.g., “Meeting Room”) as this will ease handling multiple access points. After clicking the Save button, the access points will reboot. Upon reconnect, the access point will check if a more recent firmware is available. If so, they will automatically perform a firmware update. During the firmware update, the access point’s power LED will blink rapidly. Important note: Do not unplug the power while the firmware is updating. Otherwise the access point will be rendered inoperable and must be returned to the reseller. The access point will then reboot to complete the firmware update. If no new firmware is available, the access point is operational and appears as “Active” in WebAdmin. Country code selection usage (WLAN devices) Note: According to FCC regulations, all WLAN devices marketed and sold in the U.S. must be restricted to U.S. channels only. Therefore, the country code selection is applicable to non-U.S. models only. So changing the country setting of any Sophos AP sold in the U.S. will not modify authorized parameters such as RF channels, which means that the Access Point will always operate in U.S. authorized channels. Wireless Access Points Operating Instructions AP 15 Scope of supply Sophos AP 15 Security Notes Power supply 2 Detachable dipole antenna 2 screws and dowels Ethernet cable Important note: Sophos AP 15 requires Sophos UTM V 9.207 to be installed. Mounting instructions The Sophos AP 15 can be mounted on the wall. Screws are included in delivery. Controls LED Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 10/100/1000 Base-TX Wireless Access Points 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface Power Operating Instructions Technical specifications Sophos AP 15 Chassis Plastic housing, white Maximum throughput 300 Mbit/s LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11 b/g/n 2.4 GHz Antenna 2 x detachable dipole antenna (2 dBi) Connector type: RP-SMA Frequencies / channels ETSI FCC 2.412–2.472 GHz (Channels 1-13) 2.412-2.462 GHz (channels 1-11) Power supply 12 Vdc / 1 A Power consumption 2.5 W (max.) Power-over-Ethernet 802.3af Dimensions W x H x D 194 x 32 x 115 mm Weight 260g Temperature range Operating: 0°C to 45°C Humidity (non-condensing) 0% to 90% Mounting Desktop / wall Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs Regulatory compliance Wireless Access Points Storage: -20°C to 60°C CE FCC Radio: EN 300328 CFR 47, Part 15 Subpart C EMC: EN 301489-1, EN 301489-17 CFR 47, Part 15 Subpart B EMF: EN 50385 FCC 1.1310, IEEE C95.1 Safety: EN 60950-1 N/a Operating Instructions AP 15 Mounting template 12 cm (4,72 in) Do not shrink to fit when printing Wireless Access Points Operating Instructions AP 15C Scope of supply Sophos AP 15C Security Notes Power-over-Ethernet (PoE) injector + power cord Mounting bracket Screws and T-rail clips Ethernet cable Important note: Sophos AP 15C requires Sophos UTM V 9.400 to be installed. Mounting instructions The Sophos AP 15C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket. 1. M ount the bracket on the ceiling Use the screws and anchors from the scope of supply. 2. Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop. Controls LED Console Power 1 x 10/100/1000 Base-TX Wireless Access Points Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface Operating Instructions Technical specifications Sophos AP 15C Chassis Plastic, white Physical security Kensington lock Maximum theoretical throughput 300 Mbps (5GHz / 802.11an) + 300 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n Antenna 4 x internal antennas Frequencies / channels ETSI 2.412-2.472GHz (channels 1-13) 5.180-5.240GHz (channels 36-48) FCC 2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-3: 5.745-5.825GHz (channels 149-165) MIC 2.412-2.472GHz (channels 1-13) Power supply 12 Vdc / 1 A Power consumption 7 W (max.) Power-over-Ethernet 802.3af/at Diameter x H 176 x 29.86mm Weight 265g Temperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90% Mounting Ceiling Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs Regulatory compliance CB, CE, UL, FCC, IC, MIC, VCCI, RCM Wireless Access Points W52: 5.180-5.240GHz (channels 36-48) Operating Instructions AP 55 Scope of supply Sophos AP 55 Security Notes Power-over-Ethernet (PoE) injector + power cord 2 Detachable dipole antenna 4 screws, dowels and metal plates Ethernet cable Important note: Sophos AP 55 requires Sophos UTM V 9.308 to be installed. Mounting instructions The Sophos AP 55 can be mounted on the wall. A mounting kit is included in delivery. Controls LED Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface Console Console access for debugging purposes USB Currently not used; reserved for future use Console USB 10/100/1000 Base-TX Power Wireless Access Points Operating Instructions Technical specifications Sophos AP 55 Chassis Plastic housing, white Physical security Kensington lock Maximum theoretical throughput 867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/ac Antenna 2 x detachable dipole antenna (2 dBi) Frequencies / channels ETSI 2.412–2.472 GHz (Channels 1-13) Connector type: RP-SMA RLAN sub-band 1: 5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC 2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 4 A Power consumption 11 W (max.) Power-over-Ethernet 802.3at Dimensions W x H x D 183 x 36 x 183 mm Weight 500g Temperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90% Mounting Desktop / wall Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs 8 per radio (16 in total) Regulatory compliance Wireless Access Points CE FCC Radio: EN 300 328, EN 301 893 CFR 47, Part 15 Subpart C, E EMC: EN 301 489-1, EN 301 489-17 CFR 47, Part 15 Subpart B EMF: EN 50385 FCC 1.1310, IEEE C95.1 Safety: EN 60950-1 N/a 10 Operating Instructions AP 55C Scope of supply Sophos AP 55C Security Notes Power-over-Ethernet (PoE) injector + power cord Mounting bracket Screws and T-rail clips Ethernet cable Important note: Sophos AP 55C requires Sophos UTM V 9.308 to be installed. Mounting instructions The Sophos AP 55C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket. 1. M ount the bracket on the ceiling Use the screws and anchors from the scope of supply. 2. Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop. Controls LED Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 1 x 10/100/1000 Base-TX Wireless Access Points Power 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface 11 Operating Instructions Technical specifications Sophos AP 55C Chassis Top enclosure: plastic, white; bottom enclosure: metal, white Physical security Kensington lock Maximum theoretical throughput 867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/ac Antenna 4 x internal antennas Frequencies / channels ETSI 2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1: 5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC 2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 1.5 A Power consumption 13 W (max.) Power-over-Ethernet 802.3at Diameter x H 200 x 37mm Weight 630g Temperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90% Mounting Ceiling Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs 8 per radio (16 in total) Regulatory compliance Wireless Access Points CE FCC Radio: EN 300 328, EN 301 893 CFR 47, Part 15 Subpart C, E EMC: EN 301 489-1, EN 301 489-17 CFR 47, Part 15 Subpart B EMF: EN 50385 FCC 1.1310, IEEE C95.1 Safety: EN 60950-1 UL-60950-1, UL-2043 (plenum rated) 12 Operating Instructions AP 100 Scope of supply Sophos AP 100 Security Notes Power-over-Ethernet (PoE) injector + power cord 3 Detachable dipole antenna 4 screws, dowels and metal plates Ethernet cable Important note: Sophos AP 100 requires Sophos UTM V 9.207 to be installed. Mounting instructions The Sophos AP 100 can be mounted on the wall. A mounting kit is included in delivery. Controls LED Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface Console Console access for debugging purposes USB Currently not used; reserved for future use Console USB 10/100/1000 Base-TX Power Wireless Access Points 13 Operating Instructions Technical specifications Sophos AP 100 Chassis Plastic housing, white Physical security Kensington lock Maximum theoretical throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/ac Antenna 3 x detachable dipole antenna (2 dBi) Frequencies / channels ETSI 2.412–2.472 GHz (Channels 1-13) Connector type: RP-SMA RLAN sub-band 1: 5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC 2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 4 A Power consumption 13 W (max.) Power-over-Ethernet 802.3at Dimensions W x H x D 183 x 36 x 183 mm Weight 505g Temperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90% Mounting Desktop / wall Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs 8 per radio (16 in total) Regulatory compliance Wireless Access Points CE FCC Radio: EN 300 328, EN 301 893 CFR 47, Part 15 Subpart C, E EMC: EN 301 489-1, EN 301 489-17 CFR 47, Part 15 Subpart B EMF: EN 50385 FCC 1.1310, IEEE C95.1 Safety: EN 60950-1 N/a 14 Operating Instructions AP 100C Scope of supply Sophos AP 100C Security Notes Power-over-Ethernet (PoE) injector + power cord Mounting bracket Screws and T-rail clips Ethernet cable Important note: Sophos AP 100C requires Sophos UTM V 9.308 to be installed. Mounting instructions The Sophos AP 100C can be mounted on the ceiling. Screws are included in delivery. Use the screws from the scope of supply or screws whose dimensions correspond with the mounting holes in the bracket. 1. M ount the bracket on the ceiling Use the screws and anchors from the scope of supply. 2. Place the access point on the bracket Place the housing on the bracket and lock it by turning clockwise until stop. Controls LED Green - blinking slowly AP is booting Green - blinking rapidly Network connectivity Orange - blinking slowly No connection to the Sophos UTM Orange - blinking rapidly Firmware update Interfaces and buttons 1 x 10/100/1000 Base-TX Wireless Access Points Power 12V DC-IN Power LAN (PoE) 10/100/1000 Base-TX interface 15 Operating Instructions Technical specifications Sophos AP 100C Chassis Top enclosure: plastic, white; bottom enclosure: metal, white Physical security Kensington lock Maximum theoretical throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n) LAN interfaces 1 x 10/100/1000 Base-TX Supported WLAN standards 802.11a/b/g/n/ac Antenna 6 x internal antennas Frequencies / channels ETSI 2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1 5.180-5.320GHz (channels 36-64) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC 2.412-2.462GHz (channels 1-11) U-NII-1: 5.180-5.240GHz (channels 36-48) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165) Power supply 12 Vdc / 1.5 A Power consumption 15 W (max.) Power-over-Ethernet 802.3at Diameter x H 200 x 37mm Weight 630g Temperature range Operating: 0°C to 50°C Humidity (non-condensing) 0% to 90% Mounting Ceiling Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS) Number of supported SSIDs 8 per radio (16 in total) Regulatory compliance Wireless Access Points CE FCC Radio: EN 300 328, EN 301 893 CFR 47, Part 15 Subpart C, E EMC: EN 301 489-1, EN 301 489-17 CFR 47, Part 15 Subpart B EMF: EN 50385 FCC 1.1310, IEEE C95.1 Safety: EN 60950-1 UL-60950-1, UL-2043 (plenum rated) 16 Operating Instructions AP 100X Scope of supply Sophos AP 100X Security Notes 6 antenna Power-over-Ethernet (PoE) injector + power cord 4 wood screws and wood/gyprock plug, 4 M6 screws and washers 2 metal straps 1 wall mount plate 1 M25 cable gland Ethernet cable Grounding wire Important note: Sophos AP 100X requires Sophos UTM V 9.308 to be installed. Mounting instructions The Sophos AP 100X can be mounted on a pole. A mounting kit is included in delivery. Warning: The equipment has a separate protective earthing terminal on the chassis that must be permanently connected to earth ground to adequately ground the chassis and protect the operator from electrical hazards. Caution: Before equipment installation begins, ensure that a service personnel has attached an appropriate grounding lug to the grounding cable that you supply. Connect a ground cable from the outdoor unit to an appropriate grounding point. Power installation must be performed with qualified electrician and followed with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1. To connect earth ground to Unit: ÌÌ Connect one end of the grounding cable to a proper earth ground. ÌÌ Place the grounding lug attached to the grounding cable over the protective earthing terminal. 10/100/1000 Base-TX ÌÌ Secure the grounding lug to the protective earthing terminal with the washers and screws. ÌÌ Dress the grounding cable and ensure that it does not touch or block access to other components. Warning: At first before powered on, connect the frame of the unit to earth. For earthing wire, green-and-yellow insulation is required and the cross-sectional area of the conductor must be more than 0.75mm2 or 18 AWG. Controls LED Power (Green) - continuously on Power on WLAN (Green) - blinking rapidly WLAN activity WLAN (Green) - blinking regularly Firmware update LAN (Green) - blinking rapidly Network connectivity Interfaces and buttons Wireless Access Points LAN (PoE) 10/100/1000 Base-TX interface Reset Currently not supported 17 Operating Instructions Technical specifications Sophos AP 100X Mounting Wall / Pole Chassis Metal housing, white IP Code 67 Maximum throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n) Multiple SSIDs 8 per radio, 16 in total Number of radios MIMO capabilities 3x3:3 LAN interfaces 1 x 10/100/1000 Base-TX Antenna 6 x external dipole antenna Antenna gain 4 dBi @ 2.4GHz, 6 dBi @5GHz Supported WLAN standards 802.11a/b/g/n/ac Frequencies / channels ETSI Connector type: N-Type 2.412-2.472GHz (channels 1-13) RLAN sub-band 2: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) FCC 2.412-2.462GHz (channels 1-11) U-NII-2: 5.260-5.320GHz (channels 52-64) U-NII-2e: 5.500-5.580GHz (channels 100-116) 5.660-5.700GHz (channels 132-140) U-NII-3: 5.745-5.825GHz (channels 149-165) Dimensions W x H x D 255 x 225 x 90 mm Weight 2.5kg Power supply PoE only Power consumption 15 W (max.) Power-over-Ethernet 802.3at Temperature range Operation: -20°C to 60°C Storage: -30°C to 60°C Humidity (non-condensing) Operation: 0% to 90% Storage: 0% to 95% Regulatory compliance Wireless Access Points CE FCC UL Radio: EN 300 328, EN 301 893 CFR 47, Part 15 Subpart C Section 15.247 and Subpart E Section 15.407 N/a EMC: EN 301489-1, EN 301489-17 CFR 47, Part 15 Subpart B N/a EMF: EN 62311 CFR 47, Part 2 (Section 2.1091) N/a Safety: EN 60950-22 N/a UL 60950-22 18 Operating Instructions Power-over-Ethernet injector Optionally included with AP 15C, AP 55, AP 55C, AP 100, AP 100C and AP 100X The PoE injector converts alternating current (AC) to direct current (DC), which is then provided over the Ethernet cable to power the Sophos Access Points. Installation Warning: Do not use crossover cable between the PoE injector’s output port and the access point. Before placing the PoE injector, please pay attention to the following safety instructions: ÌÌ Do not cover the PoE injector or block the airflow to the PoE with any foreign objects. Keep the PoE away from excessive heat and humidity and free from vibration and dust. ÌÌ Ensure that the cable length from Ethernet network source to the access point does not exceed 100 m (330 ft). The PoE is not a repeater and does not amplify the Ethernet data signal. To install the PoE injector, proceed as follows: 1. Connect an Ethernet cable to the Data & Power Out interface. 2. Connect the other end of this Ethernet cable to the Ethernet interface of the access point. 3. Connect an Ethernet cable to the Data In interface. 4. Connect the other end of this Ethernet cable to your network switch. 5. Connect the AC power cord from the scope of supply to the PoE injector. 6. Connect the AC power cable to an AC outlet (100-240 VAC). Controls LED display LED Data & Power Out Data In Off Power off Yellow continuously Power on Green continuously A remote terminal is connected Green blinking Overload state or short-circuit Interfaces Input (Data In) 1 x 10/100/1000 Base-TX Output (Data & Power Out) 1 x 10/100/1000 Base TX, plus 55 VDC Power Wireless Access Points 19 Operating Instructions Technical specifications Chassis Plastic housing Input power AC Input Voltage: 100 to 240 VAC AC Input Current: 0.8A @ 100-240 VAC AC Frequency: 50 to 60 Hz Power-over-Ethernet output (max.) Output power voltage: 55 VDC Output power: 30 W Supported PoE standard 802.3at compliant Weight 200g Dimensions W x H x D 1 x 10/100/1000 Base TX, plus 55 VDC Mounting Desktop / wall Temperature 0°C to 40°C (operating) -20°C to 70°C (storage) United Kingdom and Worldwide Sales Tel: +44 (0)8447 671131 Email: sales@sophos.com Humidity (non-condensing) 10% to 90% Regulatory compliance CE, FCC, VCCI, UL, GS, RoHS, WEEE North American Sales Toll Free: 1-866-866-2802 Email: nasales@sophos.com Oxford, UK | Boston, USA © Copyright 2015. Sophos Ltd. All rights reserved. Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are trademarks or registered trademarks of their respective owners. 2015-12-16 OINA (DD-2252) Australia and New Zealand Sales Tel: +61 2 9409 9100 Email: sales@sophos.com.au Asia Sales Tel: +65 62244168 Email: salesasia@sophos.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2015:12:17 14:00:20Z Creator : Adobe InDesign CC 2015 (Macintosh) Modify Date : 2015:12:25 16:43:07+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2015:12:25 16:43:07+08:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:ead68903-0e01-4bca-9d52-4eb8c9528cf6 Original Document ID : xmp.did:428771621F46DF1192D5DF5BEAAA6BB5 Document ID : xmp.id:de98fa40-2ba3-4ecc-b0cd-ed793042973d Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:8d92051c-bd36-4e78-8b05-1fb0398c7628 Derived From Document ID : xmp.did:a90c91b6-401b-415c-ab47-dbea933d9e97 Derived From Original Document ID: xmp.did:428771621F46DF1192D5DF5BEAAA6BB5 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2015:12:17 14:00:20Z Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 21EXIF Metadata provided by EXIF.tools