Source Pro SP2618FPBT Electric Fireplace Heater with Bluetooth Apps Control User Manual SP2618 HE FGPBBT 2016070 E ETL SP

Source Pro Industries Ltd. Electric Fireplace Heater with Bluetooth Apps Control SP2618 HE FGPBBT 2016070 E ETL SP

User Manual

Download: Source Pro SP2618FPBT Electric Fireplace Heater with Bluetooth Apps Control User Manual SP2618 HE FGPBBT 2016070 E ETL SP
Mirror Download [FCC.gov]Source Pro SP2618FPBT Electric Fireplace Heater with Bluetooth Apps Control User Manual SP2618 HE FGPBBT 2016070 E ETL SP
Document ID3072457
Application ID45p35k1bPLKNq6CbUpuA6A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize226.64kB (2833031 bits)
Date Submitted2016-07-21 00:00:00
Date Available2016-07-21 00:00:00
Creation Date2016-07-15 17:12:24
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2016-07-15 17:12:24
Document TitleSP2618-HE-FGPBBT_2016070_E_ETL_SP
Document CreatorAdobe Illustrator CS6 (Windows)

IMPORTANT
Please note when you open the carton carefully check the unit and make sure there is no damage. If you
have any problem with assembling the unit, with how the various functions work or with damage or
missing parts. Please call# +1-844-455-4621 (9:00AM - 5:00PM EST) or email:
serviceprokonian@jakeglobal.com immediately for service before return the unit to the store where it
was purchased.
Insert Model:
SP2618-HE-FGPBBT
INSTRUCTION MANUAL ENCLOSED
ELECTRIC FIREPLACE HEATER
HOME OWNER’S INSTRUCTION MANUAL
Model: SP2618-HE-FGPBBT
ATTENTION
FIND A LOCATION FOR THE FIREPLACE HEATER THAT IS PROTECTED FROM DIRECT
SUNLIGHT.
FAILURE TO READ ALL INSTRUCTIONS MAY RESULT IN A POSSIBLE ELECTRIC SHOCK, FIRE
HAZARD AND / OR INJURY WILL VOID THE WARRANTY
CONSUMER SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING AND OPERATING THIS APPLIANCE
WARNING
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRIC SHOCK
OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
Thank you and congratulations on your purchase of a Source Pro fireplace. Please read
the installation & operating instructions before using this appliance.
ATTENTION
Also RequiresWood Fireplace Mantel
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the product.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada Licence-exempt RSS-210. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
CAUTION: To maintain compliance with the RF exposure guidelines, place the base unit at least 20cm from nearby persons.
WARNING: Changes or modifications to this unit not expressly approved by party responsible for compliance could void the
user’s authority to operate the equipment.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric
shock and injury to persons, including the following:
Read all instructions before installing or using the heater.
DANGER: If the information in this manual is not followed exactly, an electric shock or fire may result causing
property damage, personal injury or loss of life.
WARNING: This appliance is hot when in use. To avoid burns, DO NOT let bare skin touch hot surfaces. Keep
combustible material, such as furniture, pillows, bedding, papers, clothes and curtains, at least 3 feet from
the front of the heater and keep them away from the side and rear.
WARNING: Extreme caution is necessary when any heater is used by or near children or individuals with
disabilities and whenever the fireplace is left operating and unattended.
WARNING: DO NOT run cord under carpeting. DO NOT cover cord with throw rugs, runners, or similar
covering.Do not route cord under furniture or appliances. Arrange cord away from traffic areas and where it
will not be tripped over.
WARNING: Do NOT insert or allow foreign objects to enter any ventilation or exhaust opening as this may
cause an electric shock or fire, or damage the appliance.
WARNING: This appliance has hot and arcing or sparking parts inside. DO NOT use it in areas where gasoline,
paint or flammable vapors or liquids are used or stored. This fireplace should not be used as a drying rack for
clothing. Christmas stockings or decorations should not be hung in the area of it.
SAFETY INFORMATION
Use this appliance only as described in the manual. Any other use is NOT recommended by the manufacturer and
may cause fire, electric shock or injury to persons.
CAUTION
• If possible, ALWAYS unplug this appliance when not in use.
• DO NOT operate any heater with a damaged cord or plug or after the heater malfunctions.
• DO NOT operate any heater if it has been dropped or damaged in any manner. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
• Any repairs to this fireplace should be carried out by a qualified service person.
• Under no circumstances should this fireplace be modified. Parts having to be removed for servicing must be
replaced prior to operating this fireplace again.
• DO NOT use outdoors.
• This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. NEVER place heater
where it may fall into a bathtub or other water container.
• To disconnect this appliance, turn controls to the off position, then remove plug from outlet.
• ONLY connect to properly grounded outlets.
• This appliance, when installed, must be electrically grounded in accordance with local codes, with the current
CSA C22.1 Canadian Electrical Code or follow the National Electrical Code, ANSI/NFPA N0.70.
• To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. DO NOT use on soft surfaces, like
a bed, where opening may become blocked.
• The heaters MUST NOT be located immediately below a socket-outlet.
• ALWAYS plug heaters directly into a wall outlet/receptacle. NEVER use with an extension cord or relocatable
power tap (outlet/power strip).
• There is a thermostat protective device provide inside of unit. If the inner temperature overheats or abnormal
heating occurs, the thermostat protective device will cut off power supply to prevent damage or risk of fire.
• DO NOT slide insert on top of wood to avoid scratching wood surface.
• DO NOT place any objects on top of insert and top air intake vents as this will cause unit to overheat and can
cause a fire.
Electrical Connection
ELECTRICAL SPECIFICATIONS
• A 15-amp, 120-volt, 60 Hz circuit with a properly grounded outlet is
required. Preferably, the fireplace will be on a dedicated circuit as other
appliances on the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The unit comes
standard with 6-ft. three-wire cord, exiting from the rear of the
fireplace. DO NOT exceed the current rating of the current tap. ALWAYS
plug heaters directly into a wall outlet/receptacle. NEVER use with an
extension cord or relocatable power tap (outlet/power strip).
Voltage: 120 VAC, 60 Hz
Amps: 11.7 Amps
Watts: 1400 Watts
• This heater is for use on 120 volts. The cord has a plug as shown
below. See illustration for grounding instruction. An adapter as shown
at C is available for connecting three-blade grounding type plugs to
two-slot receptacles. The green grounding lug extending from the
adapter must be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if a three-slot
grounded receptacle is available.
Metal
Screw
Cover of
Grounding
Grounding Pin
A B Box
C D
Grounding Means
Adapter
Grounding Pin
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTION
1. Position your completed mantel close to its final location. Make sure you can access the back of the mantel as
your electric fireplace insert will be install from the back.
2. Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of
your mantel during assembly. Please DO NOT fully tighten the KD screws until all panels are assembled.
3. The fireplace insert can be installed after the mantel has been fully assembled.
WARNING: Make sure the fireplace insert controls are in the OFF position and the unit is NOT plugged in.
CAUTION - High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at
least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the
heater.
INSTALLATION
ELECTRIC
FIREPLACE
INSERT
Rear view of fireplace
OPERATING INSTRUCTIONS
Note: Heater must be properly installed before it is used.
Power Button
• Pressing the power button will turn ON or OFF the unit.
• When the unit is in ON mode, the power icon indicator light will be shown green.
• When the unit is in OFF mode, the power icon indicator light will be shown red. When power OFF, unit will be
stopped, if heater is working before power OFF the unit, fan will have 20 seconds delay to ensure heat will not
be trapped inside the unit.
Note: When plug the unit each time, 5 seconds fan and heater will turn on for internal check program.
Note: The unit has a memory function with last settings for heating level and flame brightness effect, unless the
main power to the unit has been interrupted.
Mode Button
• Press the mode button to cycle through the different functions. Each time the mode button is pressed, the
mode will enter the next function - Temperature, Timer or Flame Brightness.
Temperature Setting
• The temperature mode controls the heater’s thermostat setting.
• Press UP Arrow Button or Down Arrow Button to scroll through the pre-set temperature range from 59°F (15°C)
to 86°F (30°C), ON & OF (OFF).
• Hold the mode button for 3s, this allows the temperature unit changing from °C to °F or °F to °C. The unit
default is °F.
Note: This function is only available if using the control panel.
• When the ambient temperature is higher than the set temperature, heater will turn off automatically.
Timer Setting
• The timer setting shoud be used to set the countdown for the unit’s main power.
• Press Up Arrow Button or Down Arrow Button to adjust the timer setting from 0 hour (OFF) to 9 hours with 0.5
hour interval.
Flame Brightness Setting
• The flame brightness mode should be used to set the flame brightness.
• Use Up arrow button or Down arrow button to scroll through the flame brightness settings:
F0 (Flame OFF, only lowest brightest on ember bed), F1, F2, F3, F4, F5 (brightest).
OPERATING INSTRUCTIONS
Flame Color Setting
• The flame brightness mode should be used to set the flame brightness.
• Use Up arrow button or Down arrow button to scroll through the flame brightness settings:
C1, C2, C3, C4
Setting
Color
Setting
Color
C1
Yellow
C3
C2
Blue
Yellow + Blue
Auto Change
(Fade In / Fade Out)
C4
UP Arrow Button
• Use up arrow button to increase the setting of the selected function.
Down Arrow Button
• Use down arrow button to decrease the setting of the selected function.
Child Lock
Activate Child Lock
When the unit is ON, holding the POWER button for 10 seconds to activate the Child Lock function. E3 will be
displayed and "Beep Sound" for 3 times that indicate the Child Lock function activate. All function keys are
locked. When pressing any button, E3 will be displayed that indicate the Child Lock function activate.
Inactivate Child Lock
To inactivate the Child Lock function, holding the POWER button for 10 seconds.
Note: Child lock function is only available if using the control panel.
Manually Reset
Unplug unit, wait 5-10 minutes, then the sensor will reset itself.
FIREPLACE REMOTE APP
DOWNLOAD THE FIREPLACE MOBILE APP
Bold Flame Fireplace Remote
Free Fireplace remote App gives you full
access and control of your fireplace
QR Code for download - FREE
1. Go to Apple Store or Google Play Store
2. Type “Fireplace remote” on the search bar
3. Click “download”
4. Enter your account and password if necessary
5. Installation will be completed automatically
FIREPLACE REMOTE APP
CONNECT YOUR FIREPLACE WITH FIREPLACE REMOTE
1. Turn on the fireplace
2. Switch on Bluetooth on your mobile devices
3. Tap the side menu button (Fig. 1)
Fig. 1 Tap the side menu button
(Top left)
4. Press “Add” (Fig. 2) button and start searching (Fig. 3) the Fireplace nearby
Fig. 2 Tap the ”+”button (Top left)
Fig. 3 Searching Fireplace
5. Enter a name for the fireplace (Fig. 4)
6. (Fig. 6) Blue light represents the Fireplace is connected properly and ready to use
Fig. 4 Enter a name for the
Fig. 5 Connecting Fireplace
Fig. 6 Fireplace Connected
Fireplace
7. Return to main page by clicking the side menu button
8. Make sure the right corner button is “ON” (Fig.7)
9. Adjust the color, brightness and the temperature with the Bluetooth remote
Fig. 7 Connected to Fireplace
and ready to use
Fig. 8 Long press the name to
enter edit mode
Fig. 9 Switch off the connection
by pressing the toggle
(top right)
CARE AND MAINTENACE
WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or rewiring of
this unit should be carried out by a licensed electrician in accordance with national and local codes.
If repairing or replacing and electrical component or wiring, the original wire routing, color coding and
securing locations must be followed.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a qualified
service technician to inspect te fireplace and replace any part of the electrical system.
WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,
electrical shock or personal injury.
WARNING: During any service of this appliance, the power to the unit must be turned off. First turn the
main power switch to the “OFF” position. Then remove the electrical plug from the wall outlet.
• Make sure the unit is turned OFF, unplugged and the heating elements of heater are cool whenever you are
cleaning the heater.
• Clean the heater when the heater is not in use.
• For heavy or continous use, periodic cleaning must be done more frequently.
• Clean the metal trim using a water-dampened soft, clean cloth. DO NOT use brass polish or household cleaners
as these products will damage the metal trim.
• The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and
require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater and air intake/output
vents is recommended.
• Any other servicing should be performed by an authorized service representative.
• When the heater is not in use, the heater should be stored in a dry location, away from possible damage. The
power cord should be stored properly to avoid contact with hot or sharp objects.
CARE AND MAINTENACE
Replacing the Remote Control Battery
When the remote control stops operating or its range seems reduced, it is time to replace the batteries.
Note: The batteries should be removed if the product is to be left unused for a long time.
Caution: Non-rechargeable battery is not to be recharged. Exhausted battery is to be removed from the
product.
1. The battery compartment is located on the back end of the remote control.
2. Press the small tab inward as you slide the battery door open and remove the old battery.
3. Insert a new CR2025 lithium battery (not included), ensuring the polarities of the battery match the inside of
the battery compartment.
4. Re-insert the battery door.
Disposal of Used Battery
A battery may contain hazardous substances that could be endangering to
environment and human health.
• This symbol marked on the battery and/or packaging indicates that used battery shall
not be treated as municipal waste. Instead it shall be left at the appropriate collection
point for recycling.
• By ensuring the used battery is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health. The recycling of
materials will help to conserve natural resources.
For more information about collection and recycling of used batteries, please contact your local municipality, your
waste disposal service or the point of sale where you purchased this item.
TROUBLE SHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
SOLUTION
1. No power, logs do 1. The unit does not have power.
not glow.
1. Check that unit is plugged into a standard 120
volt outlet. Then make sure power is set at “ON”
position.
2. E1 displayed on
control panel.
2. The overheat protection device has
been engaged.
2. Unplug unit, wait 5-10 minutes, then the
sensor will reset itself. Plug the unit back in and
turn on the heater. If the problem persists, call
customer service.
3. E2 displayed on
control panel.
3. The ambient temperature sensor is
broken or not working correctly.
3. Unplug unit, wait 5-10 minutes, then the
sensor will reset itself. Plug the unit back in and
turn on the heater. If the problem persists, call
customer service.
4. E3 displayed on
control panel.
4. Child lock function activate.
4. To inactivate the Child Lock function, holding
the POWER button for 10 seconds.
5. Normal operation.
5. Fan motor
continues to blow
after unit is powered
off.
5. This is a standard feature; the blower runs for
an additional 20 seconds to ensure heat will not
be trapped inside the unit.
6. Power cord gets
warm to the touch.
6. This is normal for a heater appliance as it
requires more current to operate. Check the
connections of the appliance cord and the outlet.
Make sure the plug fits tightly into the outlet.
During use, check the plug and outlet frequently
to determine if it is HOT; if so, discontinue use of
the appliance and consult with a qualified
electrician to check or change the overheating
outlet(s).
6. Normal
operation.
10
1 YEAR LIMITED WARRANTY
SOURCE PRO ELECTRIC FIREPLACE MODEL
BASIC WARRANTY
Source Pro Industries Ltd. (hereinafter referred to collectively as the (“company”) warrants that your new
Prokonian Electric Fireplace is free from manufacturing and materials defects for a period of one year from date of
purchase. Subject to following conditions and limitations.
1. The electric fireplace must be installed and operated at all times in accordance with the installation and
operating instruction furnished with the product. Any unauthorized repair, alteration, willful abuse, accident, or
misuse of the product shall nullify this warranty.
2. This warranty is non-transferable, and is made to the original owner, provided that the purchase was made
through an authorized supplier of the company.
3. The warranty is limited to the repair or replacement of part(s) found to be defective in material or
workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said
defect is confirmed by the company’s inspection.
4. This warranty does not cover the LED light bar included with the Prokonian Electric Fireplace.
5. The Company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the
wholesale price of the defective part(s).
6. Any installation, labor construction, transportation, or other related costs/expenses arising from defective
part(s), repair, replacement, or otherwise of same , will not be covered by this warranty, nor shall the Company
assume responsibility for same.
7. The owner/user assumes all other risks. If any including the risk of any direct, indirect or consequential loss or
damage arising out of the use. Or inability to use the product, except as provided by law.
8. All other warranties – expressed of implied – with respect to the product, its components and accessories, or
any obligations / liabilities on the part of the Company are hereby expressly excluded.
9. The Company neither assumes, nor authorizes any third party to assume, on it behalf, any other liabilities with
respect to the sale of the Prokonian product.
10. The warranties as outlined within this document do not apply to non Prokonian accessories used in
conjunction with the installation of this product.
11. This warranty gives you specific legal rights, and you may also have other right which vary from state to state.
This warranty is void if:
a. The fireplace is subjected to prolonged periods of dampness or condensation.
b. Any unauthorized alteration, willful abuse, accident, or misuse of the product.
c. You do not have the original receipt of purchase.
IF WARRANTY SERVICE IS NEEDED
Contact the company, at serviceprokonian@jakeglobal.com or call +1-844-455-4621 have your warranty, your
sales receipt, location of purchase and the model / serial number of your Source Pro products.
CUSTOMER SERVICE
Email: serviceprokonian@jakeglobal.com
Call: +1-844-455-4621
11
Please refer to part code when reordering
For questions or comments about product:
Email: serviceprokonian@jakeglobal.com or Call: +1-844-455-4621
Crafted in China
Distributed by Source Pro Industries Ltd.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Format                          : application/pdf
Title                           : SP2618-HE-FGPBBT_2016070_E_ETL_SP
Metadata Date                   : 2016:07:15 17:12:24+08:00
Modify Date                     : 2016:07:15 17:12:24+08:00
Create Date                     : 2016:07:15 17:12:24+09:00
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Thumbnail Width                 : 256
Thumbnail Height                : 24
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 3590 bytes, use -b option to extract)
Instance ID                     : uuid:7cb0eb95-ffa7-4f9c-b085-7ebd4e818a5b
Document ID                     : xmp.did:9604F2032B4AE611BEB3BF22A45F2820
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:4dee6d25-983f-4f51-809b-375d048b1600
Derived From Document ID        : xmp.did:70BD29071144E6119556E14C59122553
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:3C697350AB2BE611A005ED6956E6A138, xmp.iid:9604F2032B4AE611BEB3BF22A45F2820
History When                    : 2016:06:06 13:55:47+08:00, 2016:07:15 17:12:21+08:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : C:\Users\Vicky-Design\Desktop\Capture QR.JPG, C:\Users\Vicky-Design\Desktop\Google Play.png, C:\Users\Vicky-Design\Desktop\App Store.png
Startup Profile                 : Print
Has Visible Overprint           : True
Has Visible Transparency        : True
N Pages                         : 1
Max Page Size W                 : 210.088813
Max Page Size H                 : 297.087809
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, Arial-BoldMT, Calibri, Calibri-Italic, Calibri-Bold, Calibri-BoldItalic
Font Family                     : Arial, Arial, Calibri, Calibri, Calibri, Calibri
Font Face                       : Regular, Bold, Regular, Italic, Bold, Bold Italic
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.10, Version 5.08, Version 5.72, Version 5.72, Version 5.72, Version 5.72
Font Composite                  : False, False, False, False, False, False
Font File Name                  : arial_1.ttf, arialbd_0.ttf, calibri_1.ttf, calibrii_0.ttf, calibrib_0.ttf, calibriz_0.ttf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Group Name        : 明亮
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000004
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003099
Swatch Groups Colorants Black   : 0.003099
Producer                        : Adobe PDF library 10.01
Page Count                      : 13
Creator                         : Adobe Illustrator CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AFOO-SP2618FPBT