• actual manual size  4.25”W  X  5.6875”HFrontBackTESTING EQUIPMENTE3618193/16  Rev. 016040T manualContents Made in ChinaProduct distributed by Southwire Company, LLCOne Southwire Drive, Carrollton, GA 30119©2016 Southwire Company, LLC.  All rights reserved.southwiretools.com1-855-SW-T00LSToll Free Technical HelpLínea de Ayuda Técnica GratuitaUL61010-1Operating Instructions16040T True RMS Multimeter with MApp™ Mobile AppThe Bluetooth® word mark and logos are registered trademarks of Bluetooth SIG, Inc. and any use of such marks by Southwire Company, LLC is under license.Instrucciones completas de operación están disponibles en español en la página de exhibición del producto en SouthwireTools.com.10 A16040TMAXMINMODE
Introduction1The Southwire 16040T True RMS Multimeter wirelessly transmits data to the MApp™ mobile app via Bluetooth® technology allowing you to view, save, organize and share datalogs as well as take measurements from a safe distance. Visit nextgenmeters.southwiretools.com for mobile app download information. Functions include AC/DC voltage and current, resistance, continuity, capacitance, frequency, duty cycle, diode test. The 16040T also offers the added convenience of a built-in flashlight. This meter is fully tested and calibrated and, with proper use, will provide many years of reliable service.  WARNINGS࠮9LHK\UKLYZ[HUKHUKMVSSV^:HML[`9\SLZHUK6WLYH[PUN0UZ[Y\J[PVUZPU   this manual before using this meter.࠮;OLTL[LY»ZZHML[`MLH[\YLZTH`UV[WYV[LJ[[OL\ZLYPMUV[\ZLKPU       HJJVYKHUJL^P[O[OLTHU\MHJ[\YLY»ZPUZ[Y\J[PVUZ࠮,UZ\YL[OH[[OL[LZ[SLHKZHYLM\SS`ZLH[LKPU[OLPUW\[QHJRZHUKRLLW   fingers away from the metal probe tips when taking measurements.࠮)LMVYLJOHUNPUNM\UJ[PVUZ\ZPUN[OLZLSLJ[VYZ^P[JOHS^H`ZKPZJVUULJ[   the test leads from the circuit under test.࠮<ZLVUS`<3SPZ[LK[LZ[SLHKZ^P[O[OLWYVWLYZHML[`JH[LNVY`YH[PUN࠮*VTWS`^P[OHSSHWWSPJHISLZHML[`JVKLZ<ZLHWWYV]LKWLYZVUHS   protective equipment when working near live electrical circuits -        particularly with regard to arc-flash potential.࠮<ZLJH\[PVUVUSP]LJPYJ\P[Z=VS[HNLZHIV]L=(*YTZ=HJWLHR   or 60 V dc pose a shock hazard.࠮+VUV[\ZLPM[OLTL[LYVY[LZ[SLHKZHWWLHYKHTHNLK࠮=LYPM`VWLYH[PVUILMVYL\ZPUNTL[LYI`TLHZ\YPUNHRUV^USP]L]VS[HNL࠮+VUV[\ZL[OLTL[LYPU^L[VYKHTWLU]PYVUTLU[ZVYK\YPUNLSLJ[YPJHS   storms.࠮+VUV[\ZL[OLTL[LYULHYL_WSVZP]L]HWVYZK\Z[VYNHZZLZ࠮+VUV[\ZL[OLTL[LYPMP[VWLYH[LZPUJVYYLJ[S`7YV[LJ[PVUTH`IL   compromised.࠮+VUV[VWLYH[LTL[LY^OPSL3V^)H[[LY`^HYUPUNPZVU9LWSHJL   batteries immediately. ࠮+VUV[HWWS`]VS[HNLVYJ\YYLU[[OH[L_JLLKZ[OLTL[LY»ZTH_PT\T   rated input limits.REGISTER YOUR PRODUCTRegister your product purchase at www.southwiretools.com. At Southwire, we are dedicated to providing you with the best customer experience. By following a few quick steps to register, you can experience quicker service, more efficient support, and receive information on our future products. Simply WYV]PKL`V\YTVKLSU\TILYZLYPHSU\TILYHUKQ\Z[HML^WPLJLZVMinformation about yourself – it is that quick and easy. LIMITED WARRANTY AND LIMITATION OF LIABILITY ONSOUTHWIRE METERS & TESTERS:V\[O^PYL*VTWHU`33*^HYYHU[Z[OPZWYVK\J[[VILMYLLMYVTKLMLJ[ZPUmaterial and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage arising from an accident, neglect, misapplication, contamination, modification, improper maintenance or repair, operation outside of specifications, or abnormal handling of the product. :V\[O^PYL»ZZVSLSPHIPSP[`HUK[OLW\YJOHZLY»Zexclusive remedy, for any breach of this warranty is expressly limited to :V\[O^PYL»ZYLWHPYVYYLWSHJLTLU[VM[OLWYVK\J[>OL[OLY:V\[O^PYLYLWHPYZor replaces the product will be a determination that Southwire makes at its sole discretion.SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILLBE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.SOUTHWIRE MAKES NO OTHER WARRANTY, EXPRESSED ORIMPLIED, OTHER THAN THE WARRANTY SPECIFICALLY SET FORTH HEREIN. SOUTHWIRE WILL NOT BE LIABLE FOR ANY INCIDENTAL,CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES FORANY BREACH OF THIS WARRANTY.  This warranty is void if this product is used for rental purposes. No product YLZLSSLYPZH\[OVYPaLK[VL_[LUKHU`V[OLY^HYYHU[`VU:V\[O^PYL»ZILOHSMrelating to this product, and no such reseller warranty will be binding on :V\[O^PYL0M`V\OH]LH^HYYHU[`JSHPTVYPM[OLWYVK\J[ULLKZ[VILserviced during or after the warranty period set forth above, please contact[OL*\Z[VTLY:LY]PJL+LWHY[TLU[H[:>;663: The sender is responsible for all shipping, freight, insurance, and packaging costs associated with sending a product to Southwire. Southwire will not be responsible for lost or damaged products returned pursuant to this warranty.All products returned to Southwire under this warranty should be mailed to: Southwire Company, LLCAttention: Tool Warranty Return840 Old Bremen RoadCarrollton, GA 3011718
17Specifications cont.40.00nF400.0nF4.000µF40.00µF400.0µF4000µFInput Protection:   250V RMS or 250V DC  10pF0.1nF0.001µF0.01µF0.1µF1µF±(5.0% +35 digits)±(3.0% +5 digits)±(4.0% +5 digits)±(5.0% +5 digits)Capacitance  Function                Range           Resolution      Accuracy ± (% of reading + digits)400.0Ω4.000kΩ40.00kΩ400.0kΩ4.000MΩ40.00MΩInput Protection:   250V RMS or 250V DC 0.1Ω1Ω10Ω100Ω1kΩ10kΩ±(1.0% + 4 digits)±(1.5% +5 digits)±(3.5% +5 digits)Resistance  Function                Range           Resolution      Accuracy ± (% of reading + digits)Input LimitsFunction                            Maximum InputVoltage AC or DC Frequency, Duty CycleResistance, Continuity, Diode Test, CapacitanceµA, mA Current AC or DC10A Current AC or DC600V AC RMS/600V DC600 V AC RMS/600V DC250V AC RMS/250V DC  500mA 600V fast acting fuse10A 600V fast acting fuse                                           (30 seconds max. every 15 minutes)2General SpecificationsInsulation Class 2, Double insulationDiode Test Test current 0.3mA typical, open circuit voltage < 3.3V Continuity Test Audible signal if the resistance is approx. 50Ω or lessLow Battery IndicationDisplay 4000 count LCD display                                                                                                 Over Range Indication  “OL” is displayedPolarity Minus symbol “-” is displayed for negative polarityMeasurement Rate 2 readings per second, nominalAuto Power Off After approx. 15 minutes of inactivityInput Impedance 10MΩ (VDC & VAC)AC Response True RMSAC Bandwidth 50/60HzBatteries Two “AAA” 1.5V batteriesFuses µA. mA ranges: 500mA/600V (5 x 20mm) fast blow fuse10A range: 10A/600V (5 x 20mm) fast blowOperating Temperature 41°F to 104°F (5°C to 40°C) Operating Humidity Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C)Storage Temperature -4°F to 140°F (-20°C to 60°C)Storage Humidity <80%)Operating AltitudeDimensions/ Weight 4.8” x 2.6” x 1.4”/0.32lb (121 x 67 x 35mm/140g)Complies with UL 61010-1 v.3 for measurement Category lll 600V, Polution Degree 2Safety2000 meters“      ” is displayed
Insulated Tip OnInsulated Tip Removed3Potential danger. Indicates the user must refer to the manual for important safety informationIndicates hazardous voltages may be presentEquipment is protected by double or reinforced insulationIndicates the terminal(s) so marked must not be connected to a circuit where thevoltage with respect to earth ground exceeds the maximum safety rating of the meter MAX600VInternational Safety SymbolsBrief Description Typical ApplicationsCategory RatingSingle phase receptacles and connected loads Three phase circuits and single phase lighting circuits in commercial buildings - Household appliances, power tools- Outlets more than 30ft (10m) from a CAT III source- Outlets more than 60ft (20m) from a CAT IV source- Equipment in fixed installations such as 3-phase   motors, switchgear and distribution panels - Lighting circuits in commercial buildings- Feeder lines in industrial plants- Any device or branch circuit that is close to a CAT III sourceCAT IICAT IIIThe measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any accessories connected to the meter and test probes. The combination rating is the LOWEST of any individual component.Safety Category RatingsWARNING:                             Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes. Refer to Input Limits section in this manual for maximum voltage ratings. Test LeadsCAT IV  600VCAT III  1000V  CAT II1000V16Specifications cont.400.0µA4000µA40.00mA400.0mA10.00AAll AC current ranges are specified from 5% to 100% of range.Input Protection:   µA/mA ranges: 500mA/600V Fuse     10A range: 10A/600V Fuse   0.1µA1µ10µA0.1mA10mA±(2.0% +5 digits)±(2.5% +5 digits)±(3.0% +7 digits)AC Current50/60Hz  Function                Range           Resolution      Accuracy ± (% of reading + digits)400.0µA4000µ40.00mA400.0mA10.00AInput Protection:   µA/mA ranges: 500mA/600V Fuse     10A range: 10A/600V Fuse     0.1µA1µA10µA0.1mA10mA±(1.0% +3 digits)±(1.5% +3 digits)±(2.5% +5 digits)DC Current  Function                Range           Resolution      Accuracy ± (% of reading + digits)
4FCC StatementWarning: Changes or modifications to this unit not expressly approved by the Southwire Co. could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of theFCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  • Reorient or relocate the receiving antenna.  • Increase the separation between the equipment and receiver.  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  • Consult the dealer or an experienced radio/TV technician for help.The device must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Complies withIDA StandardsDA10739215Specifications cont.4.000V40.00V400.0V600VAll AC voltage ranges are specified from 5% to 100% of range.Input Protection:   600V RMS or 600V DC Accuracy is given at 65°F to 83°F (18°C to 28°C), less than 70% relative humidity1mV10mV0.1V1V±(1.0% +5 digits)±(1.2% +5 digits)AC Voltage50/60Hz  Function                Range           Resolution      Accuracy ± (% of reading + digits)400.0mV4.000V40.00V400.0V600VInput Protection:   600V RMS or 600V DC0.1mV1mV10mV0.1V1V±(1.0% +8 digits)±(1.0% +3 digits)±(1.2% +3 digits)DC Voltage  Function                Range           Resolution      Accuracy ± (% of reading + digits)9.999Hz99.99Hz999.9Hz9.999kHzInput Protection:   600V RMS or 600V DC0.001Hz0.01Hz0.1Hz1Hz±(1.0% +5 digits)FrequencySensitivity: 100V < 50Hz50V 50 to 400Hz5V > 400Hz to 4000Hz                        Function                Range           Resolution      Accuracy ± (% of reading + digits)20.0% to 80.0%Input Protection:   600V RMS or 600V DC0.1% ±(1.2% +5 digits)% Duty CyclePulse width: >100us, <100ms; Frequency width: 5Hz – 150kHzSensitivity: >1V RMS                         Function                Range           Resolution      Accuracy ± (% of reading + digits)FCC ID:  2AENI-16040T /  IC:  20144-16040TMaintenanceThis Multimeter is designed to provide years of dependable service, if the following care instructions are performed:1. KEEP THE METER DRY. If it gets wet, wipe it off.2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can     shorten the life of the electronic parts and distort or melt plastic parts.3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic     parts or the case.4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use     chemicals, cleaning solvents, or detergents.5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or     weak batteries so they do not leak and damage the unit.6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should     be removed to prevent damage to the unit.IC StatementThis device complies with RSS247 of Industry Canada. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Radiation Exposure Statement: This product complies with the Canadian portable RF exposure limit set forth for an uncontrolled environment and is safe for its intended operation as described in this manual.  Further RF exposure reduction can be achieved if the product is kept as far as possible from the user’s body.Déclaration de conformité d’Industrie CanadaLeprésent appareil est conforme aux CNR d'Industrie Canada applicable aux appareils radio Exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement."Déclaration d’exposition aux radiations : Ce produit est conforme aux limites d’exposition pour les appareils portables RF pour le Canada établies pour un environnement non contrôlé. Le produit est sûr pour un fonctionnement comme décrit dans ce manuel. La réduction aux expositions RF peut être augmentée si l’appareil peut être conservé aussi loin que possible du corps de l’utilisateur.
10 A16040TMAXMINMODE14Operation cont.1. Loosen the one Phillips     screw on the fuse cover.2. Remove the fuse cover.3. Gently remove fuse and     install new fuse into the     holder. 4. Always use a UL     recognized fuse of the     proper size and value:     500mA/600V (5 x 20mm)     fast blow for the µA/mA     ranges and 10A/600V     (5 x 20mm) fast blow for     the 10A range.5. Install the fuse cover and     tighten the screw.     To avoid electric shock, do not operate meter until battery and fuse covers are securely fastened to the meter. WARNING:         To avoid electric shock, remove the test leads from the meter before removing the battery or fuse covers..WARNINGS: Fuse ReplacementTO AVOID ELECTRIC SHOCK, REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR. WARNING  TO AVOID ELECTRIC SHOCK, REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR. WARNING  TO AVOID ELECTRIC SHOCK, REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A/600VWARNING  F500mA/600V5Meter Description1. LCD display2. MAX/MIN button3. MODE button4. Rotary function switch5. 10A input jack=£/a    mA input jack  7. COM input jack/63+)HJRSPNO[I\[[VU9. -SHZOSPNO[)S\L[VV[O® button1.2.4.5. 6.8.9.7.3.
13Operation cont.1. Loosen the one Phillips     screw on the battery cover.2. Remove the battery cover.3. Replace batteries with two     AAA batteries.4. Observe proper polarity as     shown inside battery     compartment. 5. Install the battery cover     and tighten the screw.     To avoid electric shock, do not operate meter until battery and fuse covers are securely fastened to the meter. WARNING:         To avoid electric shock, remove the test leads from the meter before removing the battery or fuse covers.WARNINGS:  Battery ReplacementTO AVOID ELECTRIC SHOCK, REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR. WARNING  6Symbols Used on LCD DisplayVA ACDC-Hz %£Fnµm kM OL  AUTOMAX/MINHVoltsAmperesAlternating currentDirect currentMinus signHertz (frequency)Percent (duty cycle)OhmsContinuityDiode testFarads (capacitance)nano (10-9)micro (10-6)milli (10-3) kilo (103) mega (106)Overload Auto Power OffLow batteryAutorangingDisplay holdMaximum/MinimumBluetooth® Technology
10 A16040TMAXMINMODE10 A16040TMAXMINMODE12Operation cont.1. Set the rotary function switch to     the               position    2. Press the MODE button until     the “nF” symbol appears on     the display. 3. Insert the black test lead into the     COM input jack and the red test     lead into the Ω input jack.4. Touch the test lead probes to the     capacitor under test. 5. Read the capacitance value on the LCD display.     It may take up to a minute to get a stable reading     on large capacitors.Capacitance Measurements     Safely discharge capacitors before taking capacitance measurements.  WARNING:  1. Set the rotary function switch to     the               position.2. Press the MODE button until     the “   ” symbol appears on the     LCD display.3. Insert the black test lead into the     COM input jack and the red test     lead into the Ω input jack.4. Touch the test lead probes to the     device or wire under test. 5. A beeper will sound if the resistance is approximately     50Ω or less and the resistance value will be shown     on the LCD display. ContinuityWIRE     Never test continuity on a live circuit.WARNING:  7OperationMODE ButtonUsed to select AC voltage, Frequency or % Duty Cycle, AC or DC current, and Ohms, Diode Test, Continuity or Capacitance.MAX/MIN Button1. Momentarily press the MAX/MIN button to activate the MAX/MIN mode. “MAX”     will appear on the LCD display and the meter will display and hold the highest     reading. The meter will update the reading when a higher “max” occurs.2. Momentarily press the MAX/MIN button again to view the lowest reading.     “MIN” will appear on the LCD display and the meter will display and hold the     lowest reading. The meter will update the reading when a lower “min” occurs. 3. Press and hold the MAX/MIN button to end MAX/MIN and return to normal     operation.   NOTE: MAX/MIN does not work on Frequency, Duty Cycle, Resistance,   Continuity, Diode Test and Capacitance. FLASHLIGHT / Bluetooth® ButtonBluetooth® wireless technology allows readings to be displayed and stored on mobile devices. To activate, press and hold the          button until the "    " symbol appears on the LCD display. The Bluetooth®  function should be disabled when not connected to a mobile device in order to conserve battery power. To turn the Bluetooth®  function off, press and hold the          button until the "    " symbol no longer appears on the display.Visit nextgenmeters.southwiretools.com for mobile app download information.To turn the flashlight on and off, momentarily press the          button. HOLD/Backlight button To freeze the reading on the LCD display, momentarily press the HOLD     button. The “     ” indicator will be displayed while the reading is being held. Momentarily press the HOLD     button again to return to normal operation.The backlight illuminates the LCD display when the ambient light is too low to view the displayed readings. To turn the backlight on, press the HOLD     button until the backlight turns on. To turn the backlight off, press the HOLD     button until the backlight turns off.H10 AMAXMINMODE10 AMAXMINMODE
10 A16040TMAXMINMODE11Operation cont.1. Set the rotary function switch to the               position.2. Press the MODE button until the “    “ symbol appears     on the LCD display. 3. Insert the black test lead into the COM input jack and     the red test lead into the Ω input jack.4. Touch the test lead probes to the diode under test. 5. Forward voltage will indicate 0.4 to     0.7 on the LCD display. Reverse     voltage will indicate “OL”. Shorted     devices will indicate near 0 and     an open device will indicate “OL”     in both polarities.Diode Test    Never test diodes in a live circuit.  WARNING:   Red               Black     Black           Red Probe            Probe    Probe           Probe Forward test   Reverse test    1. Set the rotary function switch to the                   position. 2. Press the MODE button until the “Ω”     symbol appears on the display. 3. Insert the black test lead into the COM     input jack and the red test lead into     the Ω input jack.4. Touch the test lead probes to the component     under test. If the component is installed in a     circuit, it is best to disconnect one side before     testing to eliminate interference with other devices.5. Read the resistance in on the LCD display.Resistance Measurements     Never test resistance on a live circuit  WARNING:  Ω10 A16040TMAXMINMODE10 A16040TMAXMINMODE81. Set the rotary function     switch to the     position. 2. Insert the black test lead     into the COM input jack and     the red test lead into     the V input jack. 3. Touch the test lead probes     to the circuit under test.4. Read the voltage on the LCD display.AC Voltage Measurements      Observe all safety precautionswhen working on live voltages.WARNING:  Operation cont.VV- +1. Set the rotary function switch     to the V  position. 2. Insert the black test lead into the     COM input jack and the red test     lead into the V input jack. 3. Touch the test lead probes to     the circuit under test. Touch the     red test lead to the positive side     of the circuit and the black test     lead to the negative side of the circuit.4. Read the voltage on the LCD display.DC Voltage Measurements      Observe all safety precautionswhen working on live voltages.WARNING:  10 AMAXMINMODE10 AMAXMINMODE10 AMAXMINMODE10 AMAXMINMODE
10 A16040TMAXMINMODE10 A16040TMAXMINMODE9OperationHz1. Set the rotary function switch to the                 position.2. Press the MODE button once to select     frequency. The “Hz” symbol will appear     on the display. To select Duty Cycle,     press the MODE button a second time.     The “%” symbol will appear on the display. 3. Insert the black test lead into the COM input jack     and the red test lead into the V input jack. 4. Touch the test lead probes to the circuit under test.5. Read the frequency or % duty cycle on the LCD display.6. Pressing the MODE button a third time will return the     meter to the voltage function. Frequency and % Duty Cycle Measurements     Observe all safety precautions when working on live live voltages.WARNING:  -+-+-+10Operation cont.10 AMAXMINMODE1. Insert the black test lead into the COM     input jack.2. For current measurements up to 10A AC/DC,     set the rotary function switch to the 10A     position and insert the red test lead into     the 10A input jack.3. For current measurements up to 400mA     AC/DC, set the rotary function switch to     the mA position and insert the red test     lead into the mA input jack. 4. For current measurements up to 4000µA     AC/DC, set the rotary function switch to     the µA position and insert the red test lead     into the mA input jack.5. Press the MODE button to select AC or     DC current. The “AC” or “DC” symbol     will appear on the LCD display.6. Remove power from the circuit under test,     then open up the circuit at the point where     you wish to measure current.7. Touch the test lead probes in series with     the circuit being measured. For DC current,     touch the red probe to the positive side of     the circuit and touch the black probe to the     negative side of the circuit.8. Apply power to the circuit.9. Read the current on the LCD display.AC/DC Current Measurements     Observe all safety precautions when working on live circuits. Do not measure current on circuits that exceed 600V. Measurements in the 10A range should be limited to 30 seconds every 15minutes.WARNING:  MEASUREMENTS UP TO 10A AC/DCMEASUREMENTS UP TO 400mA AC/DC 10 AMAXMINMODEMEASUREMENTS UP TO 4000µA AC/DC 10 AMAXMINMODE10 AMAXMINMODE10 AMAXMINMODE10 AMAXMINMODE