Southwire 16040T True RMS MultiMeter User Manual

Southwire Co. True RMS MultiMeter

User manual

Download: Southwire 16040T True RMS MultiMeter User Manual
Mirror Download [FCC.gov]Southwire 16040T True RMS MultiMeter User Manual
Document ID3012979
Application IDDoCaCUrXEH1ii13uu2JSNQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize92kB (1150002 bits)
Date Submitted2016-06-01 00:00:00
Date Available2016-06-01 00:00:00
Creation Date2016-06-01 15:06:29
Producing SoftwareGPL Ghostscript 9.0
Document Lastmod2016-06-01 15:06:29
Document TitleUser manual.pdf
Document CreatorPDFCreator Version 1.2.0
Document Author: ferry-al

3/16 Rev. 0
16040T manual
The BluetoothÂŽ word mark and logos are registered
trademarks of Bluetooth SIG, Inc. and any use of such
marks by Southwire Company, LLC is under license.
Contents Made in China
Product distributed by Southwire Company, LLC
One Southwire Drive, Carrollton, GA 30119
Š2016 Southwire Company, LLC. All rights reserved.
LĂ­nea de Ayuda TĂŠcnica Gratuita
Toll Free Technical Help
1-855-SW-T00LS
southwiretools.com
Back
10A
MAX
MIN
TESTING EQUIPMENT
E361819
• actual manual size 4.25”W X 5.6875”H
Instrucciones completas de operaciĂłn estĂĄn disponibles en espaĂąol
en la pĂĄgina de exhibiciĂłn del producto en SouthwireTools.com.
UL61010-1
MODE
16040T
16040T True RMS Multimeter with MApp™ Mobile App
Operating Instructions
Front
Introduction
ŕ Ž9LHK\UKLYZ[HUKHUKMVSSV^:HML[`9\SLZHUK6WLYH[PUN0UZ[Y\J[PVUZPU
this manual before using this meter.
ŕ Ž;OLTL[LYÂťZZHML[`MLH[\YLZTH`UV[WYV[LJ[[OL\ZLYPMUV[\ZLKPU
HJJVYKHUJL^P[O[OLTHU\MHJ[\YLYÂťZPUZ[Y\J[PVUZ
ŕ Ž,UZ\YL[OH[[OL[LZ[SLHKZHYLM\SS`ZLH[LKPU[OLPUW\[QHJRZHUKRLLW
fingers away from the metal probe tips when taking measurements.
ŕ Ž)LMVYLJOHUNPUNM\UJ[PVUZ\ZPUN[OLZLSLJ[VYZ^P[JOHS^H`ZKPZJVUULJ[
the test leads from the circuit under test.
ŕ ŽOL[OLY:V\[O^PYLYLWHPYZ
or replaces the product will be a determination that Southwire makes at its
sole discretion.
SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL
BE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.
SOUTHWIRE MAKES NO OTHER WARRANTY, EXPRESSED OR
IMPLIED, OTHER THAN THE WARRANTY SPECIFICALLY SET FORTH
HEREIN. SOUTHWIRE WILL NOT BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES FOR
ANY BREACH OF THIS WARRANTY.
This warranty is void if this product is used for rental purposes. No product
YLZLSSLYPZH\[OVYPaLK[VL_[LUKHU`V[OLY^HYYHU[`VU:V\[O^PYLÂťZILOHSM
relating to this product, and no such reseller warranty will be binding on
:V\[O^PYL0M`V\OH]LH^HYYHU[`JSHPTVYPM[OLWYVK\J[ULLKZ[VIL
serviced during or after the warranty period set forth above, please contact
[OL*\Z[VTLY:LY]PJL+LWHY[TLU[H[:>;663: 
The sender is responsible for all shipping, freight, insurance, and packaging
costs associated with sending a product to Southwire. Southwire will not be
responsible for lost or damaged products returned pursuant to this warranty.
All products returned to Southwire under this warranty should be mailed to:
LIMITED WARRANTY AND LIMITATION OF LIABILITY ON
SOUTHWIRE METERS & TESTERS
Register your product purchase at www.southwiretools.com. At Southwire,
we are dedicated to providing you with the best customer experience. By
following a few quick steps to register, you can experience quicker service,
more efficient support, and receive information on our future products. Simply
WYV]PKL`V\YTVKLSU\TILYZLYPHSU\TILYHUKQ\Z[HML^WPLJLZVM
information about yourself – it is that quick and easy.
Input Protection:
Capacitance
Function
Input Protection:
Resistance
Function
1Ί
10Ί
100Ί
1kΊ
10kΊ
4.000kΊ
40.00kΊ
400.0kΊ
4.000MΊ
40.00MΊ
0.001ÂľF
0.01ÂľF
0.1ÂľF
1ÂľF
4.000ÂľF
40.00ÂľF
400.0ÂľF
4000ÂľF
17
0.1nF
250V RMS or 250V DC
10pF
400.0nF
Resolution
40.00nF
Range
250V RMS or 250V DC
0.1Ί
Resolution
400.0Ί
Range
Specifications cont.
Âą(5.0% +5 digits)
Âą(4.0% +5 digits)
Âą(3.0% +5 digits)
Âą(5.0% +35 digits)
Accuracy Âą (% of reading + digits)
Âą(3.5% +5 digits)
Âą(1.5% +5 digits)
Âą(1.0% + 4 digits)
Accuracy Âą (% of reading + digits)
Storage Temperature
Storage Humidity
Operating Altitude
Dimensions/ Weight
Safety
Operating Temperature
Operating Humidity
Insulation
Diode Test
Continuity Test
Low Battery Indication
Display
Over Range Indication
Polarity
Measurement Rate
Auto Power Off
Input Impedance
AC Response
AC Bandwidth
Batteries
Fuses
600V AC RMS/600V DC
600 V AC RMS/600V DC
250V AC RMS/250V DC
500mA 600V fast acting fuse
10A 600V fast acting fuse
(30 seconds max. every 15 minutes)
Maximum Input
Class 2, Double insulation
Test current 0.3mA typical, open circuit voltage < 3.3V
Audible signal if the resistance is approx. 50Ί or less
“ ” is displayed
4000 count LCD display
“OL” is displayed
Minus symbol “-” is displayed for negative polarity
2 readings per second, nominal
After approx. 15 minutes of inactivity
10MΊ (VDC & VAC)
True RMS
50/60Hz
Two “AAA” 1.5V batteries
ÂľA. mA ranges: 500mA/600V (5 x 20mm) fast blow fuse
10A range: 10A/600V (5 x 20mm) fast blow
41°F to 104°F (5°C to 40°C)
Max 80% up to 87°F (31°C) decreasing linearly to 50%
at 104°F(40°C)
-4°F to 140°F (-20°C to 60°C)
<80%)
2000 meters
4.8” x 2.6” x 1.4”/0.32lb (121 x 67 x 35mm/140g)
Complies with UL 61010-1 v.3 for measurement
Category lll 600V, Polution Degree 2
General Specifications
Voltage AC or DC
Frequency, Duty Cycle
Resistance, Continuity, Diode Test, Capacitance
ÂľA, mA Current AC or DC
10A Current AC or DC
Function
Input Limits
Indicates the terminal(s) so marked must not be connected to a circuit where the
voltage with respect to earth ground exceeds the maximum safety rating of the meter
- Equipment in fixed installations such as 3-phase
motors, switchgear and distribution panels
- Lighting circuits in commercial buildings
- Feeder lines in industrial plants
- Any device or branch circuit that is close to a CAT III source
Three phase circuits and
single phase lighting
circuits in commercial
buildings
CAT III
Insulated Tip Removed
CAT II
1000V
CAT IV 600V
CAT III 1000V
WARNING: Operation is limited to CAT II applications when the insulated tips are
removed from one or both test probes. Refer to Input Limits section in this manual for maximum
voltage ratings.
Test Leads
Insulated Tip On
The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any accessories connected to
the meter and test probes. The combination rating is the LOWEST of any individual component.
- Household appliances, power tools
- Outlets more than 30ft (10m) from a CAT III source
- Outlets more than 60ft (20m) from a CAT IV source
Typical Applications
Single phase receptacles
and connected loads
Brief Description
CAT II
Category Rating
Safety Category Ratings
600V
MAX
Equipment is protected by double or reinforced insulation
Indicates hazardous voltages may be present
Potential danger. Indicates the user must refer to the manual for important safety information
International Safety Symbols
0.1mA
400.0mA
10mA
1Âľ
10ÂľA
10.00A
0.1ÂľA
4000ÂľA
40.00mA
Resolution
400.0ÂľA
Range
Input Protection:
DC Current
Function
10ÂľA
0.1mA
40.00mA
400.0mA
16
ÂľA/mA ranges: 500mA/600V Fuse
10A range: 10A/600V Fuse
10mA
1ÂľA
4000Âľ
10.00A
0.1ÂľA
Resolution
400.0ÂľA
Range
All AC current ranges are specified from 5% to 100% of range.
Input Protection:
ÂľA/mA ranges: 500mA/600V Fuse
10A range: 10A/600V Fuse
AC Current
50/60Hz
Function
Specifications cont.
Âą(2.5% +5 digits)
Âą(1.5% +3 digits)
Âą(1.0% +3 digits)
Accuracy Âą (% of reading + digits)
Âą(3.0% +7 digits)
Âą(2.5% +5 digits)
Âą(2.0% +5 digits)
Accuracy Âą (% of reading + digits)
1mV
10mV
0.1V
1V
40.00V
400.0V
600V
Resolution
4.000V
Range
Input Protection:
% Duty Cycle
Pulse width:
>100us, <100ms;
Frequency width:
5Hz – 150kHz
Sensitivity: >1V RMS
Function
Input Protection:
Frequency
Sensitivity:
100V < 50Hz
50V 50 to 400Hz
5V > 400Hz to 4000Hz
Function
Input Protection:
DC Voltage
Function
10mV
0.1V
1V
40.00V
400.0V
600V
0.001Hz
0.01Hz
0.1Hz
1Hz
Resolution
0.1%
Resolution
15
600V RMS or 600V DC
20.0%
to
80.0%
Range
600V RMS or 600V DC
9.999Hz
99.99Hz
999.9Hz
9.999kHz
Range
600V RMS or 600V DC
0.1mV
1mV
Resolution
400.0mV
4.000V
Range
All AC voltage ranges are specified from 5% to 100% of range.
Input Protection:
600V RMS or 600V DC
AC Voltage
50/60Hz
Function
Âą(1.2% +5 digits)
Accuracy Âą (% of reading + digits)
Âą(1.0% +5 digits)
Accuracy Âą (% of reading + digits)
Âą(1.2% +3 digits)
Âą(1.0% +3 digits)
Accuracy Âą (% of reading + digits)
Âą(1.0% +8 digits)
Âą(1.2% +5 digits)
Âą(1.0% +5 digits)
Accuracy Âą (% of reading + digits)
Accuracy is given at 65°F to 83°F (18°C to 28°C), less than 70% relative humidity
Specifications cont.
FCC ID: 2AENI-16040T / IC: 20144-16040T
This Multimeter is designed to provide years of dependable service, if the following care
instructions are performed:
1. KEEP THE METER DRY. If it gets wet, wipe it off.
2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can
shorten the life of the electronic parts and distort or melt plastic parts.
3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic
parts or the case.
4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use
chemicals, cleaning solvents, or detergents.
5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or
weak batteries so they do not leak and damage the unit.
6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should
be removed to prevent damage to the unit.
Maintenance
LeprĂŠsent appareil est conforme aux CNR d'Industrie Canada applicable aux appareils radio Exempts de licence. L'exploitation est
autorisĂŠe aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioĂŠlectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement."
Déclaration d’exposition aux radiations : Ce produit est conforme aux limites d’exposition pour les appareils portables RF pour le
Canada ĂŠtablies pour un environnement non contrĂ´lĂŠ. Le produit est sĂťr pour un fonctionnement comme dĂŠcrit dans ce manuel. La
réduction aux expositions RF peut être augmentée si l’appareil peut être conservé aussi loin que possible du corps de l’utilisateur.
Déclaration de conformité d’Industrie Canada
This device complies with RSS247 of Industry Canada. This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Complies with
Radiation Exposure Statement: This product complies with the Canadian portable RF exposure limit set
forth for an uncontrolled environment and is safe for its intended operation as described in this manual.
IDA Standards
Further RF exposure reduction can be achieved if the product is kept as far as possible from the user’s body.
DA107392
IC Statement
Warning: Changes or modifications to this unit not expressly approved by the Southwire Co. could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The device must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Statement
ÂŽ
9. -SHZOSPNO[)S\L[VV[O button
7.
5.
4.
3.
7. COM input jack
/63+)HJRSPNO[I\[[VU
2.
1.
=ÂŁ/a 
mA input jack
5. 10A input jack
3. MODE button
4. Rotary function switch
MODE
10A
MAX
MIN
16040T
6.
9.
8.
WARNING
F10A/600V
F500mA/600V
TO AVOID ELECTRIC
SHOCK, REMOVE TEST
LEADS BEFORE OPENING
CASE OR FUSE COVER
14
WARNING: To avoid electric shock, do not operate meter until
battery and fuse covers are securely fastened to the meter.
1. Loosen the one Phillips
screw on the fuse cover.
2. Remove the fuse cover.
3. Gently remove fuse and
install new fuse into the
holder.
4. Always use a UL
recognized fuse of the
proper size and value:
500mA/600V (5 x 20mm)
fast blow for the ÂľA/mA
ranges and 10A/600V
(5 x 20mm) fast blow for
the 10A range.
5. Install the fuse cover and
tighten the screw.
WARNINGS: To avoid electric shock, remove the test leads from
the meter before removing the battery or fuse covers..
WARNING
2. MAX/MIN button
TO AVOID ELECTRIC SHOCK,
REMOVE TEST LEADS BEFORE
OPENING CASE OR BATTERY DOOR.
1. LCD display
Fuse Replacement
Operation cont.
WARNING
Meter Description
TO AVOID ELECTRIC SHOCK,
REMOVE TEST LEADS BEFORE
OPENING CASE OR BATTERY DOOR.
13
WARNING: To avoid electric shock, do not operate meter until
battery and fuse covers are securely fastened to the meter.
1. Loosen the one Phillips
screw on the battery cover.
2. Remove the battery cover.
3. Replace batteries with two
AAA batteries.
4. Observe proper polarity as
shown inside battery
compartment.
5. Install the battery cover
and tighten the screw.
WARNING
WARNINGS: To avoid electric shock, remove the test leads from
the meter before removing the battery or fuse covers.
Battery Replacement
Operation cont.
TO AVOID ELECTRIC SHOCK,
REMOVE TEST LEADS BEFORE
OPENING CASE OR BATTERY DOOR.
MAX/MIN
AUTO
Âľ
OL
AC
DC
Hz
ÂŁ
Volts
Amperes
Alternating current
Direct current
Minus sign
Hertz (frequency)
Percent (duty cycle)
Ohms
Continuity
Diode test
Farads (capacitance)
nano (10-9)
micro (10-6)
milli (10-3)
kilo (103)
mega (106)
Overload
Auto Power Off
Low battery
Autoranging
Display hold
Maximum/Minimum
BluetoothÂŽ Technology
Symbols Used on LCD Display
ÂŽ
button.
HOLD/Backlight button
To freeze the reading on the LCD display, momentarily press the HOLD button.
The “ H ” indicator will be displayed while the reading is being held. Momentarily
press the HOLD button again to return to normal operation.
The backlight illuminates the LCD display when the ambient light is too low to view
the displayed readings. To turn the backlight on, press the HOLD button until the
backlight turns on. To turn the backlight off, press the HOLD button until the
backlight turns off.
To turn the flashlight on and off, momentarily press the
Visit nextgenmeters.southwiretools.com for mobile app download information.
ÂŽ
ÂŽ
ÂŽ
FLASHLIGHT / Bluetooth Button
Bluetooth wireless technology allows readings to be displayed and stored on
mobile devices. To activate, press and hold the
button until the " " symbol
appears on the LCD display. The Bluetooth function should be disabled when not
connected to a mobile device in order to conserve battery power. To turn the
button until the " " symbol no
Bluetooth function off, press and hold the
longer appears on the display.
NOTE: MAX/MIN does not work on Frequency, Duty Cycle, Resistance,
Continuity, Diode Test and Capacitance.
MODE Button
Used to select AC voltage, Frequency or % Duty Cycle, AC or DC current, and Ohms,
Diode Test, Continuity or Capacitance.
MAX/MIN Button
1. Momentarily press the MAX/MIN button to activate the MAX/MIN mode. “MAX”
will appear on the LCD display and the meter will display and hold the highest
reading. The meter will update the reading when a higher “max” occurs.
2. Momentarily press the MAX/MIN button again to view the lowest reading.
“MIN” will appear on the LCD display and the meter will display and hold the
lowest reading. The meter will update the reading when a lower “min” occurs.
3. Press and hold the MAX/MIN button to end MAX/MIN and return to normal
operation.
Operation
10A
MAX
MIN
12
1. Set the rotary function switch to
the
position
2. Press the MODE button until
the “nF” symbol appears on
the display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the Ί input jack.
4. Touch the test lead probes to the
capacitor under test.
5. Read the capacitance value on the LCD display.
It may take up to a minute to get a stable reading
on large capacitors.
MODE
WARNING: Safely discharge capacitors before
taking capacitance measurements.
Capacitance Measurements
10A
1. Set the rotary function switch to
MODE
the
position.
2. Press the MODE button until
the “ ” symbol appears on the
LCD display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the Ί input jack.
4. Touch the test lead probes to the
device or wire under test.
5. A beeper will sound if the resistance is approximately
50Ί or less and the resistance value will be shown
on the LCD display.
MAX
MIN
WARNING: Never test continuity on a live circuit.
Continuity
Operation cont.
MODE
MODE
10A
16040T
WIRE
MAX
MIN
10A
16040T
MAX
MIN
10A
MAX
MIN
10A
MAX
MIN
11
Forward test
MODE
10A
Red
Probe
Ί
16040T
MAX
MIN
Reverse test
1. Set the rotary function switch to the
position. MODE
2. Press the MODE button until the “ “ symbol appears
on the LCD display.
3. Insert the black test lead into the COM input jack and
the red test lead into the Ί input jack.
4. Touch the test lead probes to the diode under test.
5. Forward voltage will indicate 0.4 to
0.7 on the LCD display. Reverse
voltage will indicate “OL”. Shorted
Red
Black Black
devices will indicate near 0 and
Probe
Probe Probe
an open device will indicate “OL”
in both polarities.
WARNING: Never test diodes in a live circuit.
Diode Test
MODE
1. Set the rotary function switch to the
position.
2. Press the MODE button until the “Ω”
symbol appears on the display.
3. Insert the black test lead into the COM
input jack and the red test lead into
the Ί input jack.
4. Touch the test lead probes to the component
under test. If the component is installed in a
circuit, it is best to disconnect one side before
testing to eliminate interference with other devices.
5. Read the resistance in on the LCD display.
WARNING: Never test resistance on a live circuit
Resistance Measurements
Operation cont.
MODE
10A
MAX
MIN
1. Set the rotary function switch
MODE
to the V position.
2. Insert the black test lead into the
COM input jack and the red test
lead into the V input jack.
3. Touch the test lead probes to
the circuit under test. Touch the
red test lead to the positive side
of the circuit and the black test
lead to the negative side of the circuit.
4. Read the voltage on the LCD display.
10A
MAX
MIN
WARNING: Observe all safety precautions
when working on live voltages.
DC Voltage Measurements
1. Set the rotary function
switch to the
position.
2. Insert the black test lead
into the COM input jack and
the red test lead into
the V input jack.
3. Touch the test lead probes
to the circuit under test.
4. Read the voltage on the LCD display.
WARNING: Observe all safety precautions
when working on live voltages.
AC Voltage Measurements
Operation cont.
MODE
MODE
10A
10A
MAX
MIN
16040T
16040T
MAX
MIN
MAX
MIN
10A
1. Set the rotary function switch to the
position.
2. Press the MODE button once to select
frequency. The “Hz” symbol will appear
on the display. To select Duty Cycle,
press the MODE button a second time.
The “%” symbol will appear on the display.
3. Insert the black test lead into the COM input jack
and the red test lead into the V input jack.
4. Touch the test lead probes to the circuit under test.
5. Read the frequency or % duty cycle on the LCD display.
6. Pressing the MODE button a third time will return the
meter to the voltage function.
MODE
MODE
10A
MAX
MIN
Hz
16040T
10
1. Insert the black test lead into the COM
input jack.
2. For current measurements up to 10A AC/DC,
set the rotary function switch to the 10A
position and insert the red test lead into
the 10A input jack.
3. For current measurements up to 400mA
AC/DC, set the rotary function switch to
the mA position and insert the red test
lead into the mA input jack.
4. For current measurements up to 4000ÂľA
AC/DC, set the rotary function switch to
the ÂľA position and insert the red test lead
into the mA input jack.
5. Press the MODE button to select AC or
DC current. The “AC” or “DC” symbol
will appear on the LCD display.
6. Remove power from the circuit under test,
then open up the circuit at the point where
you wish to measure current.
7. Touch the test lead probes in series with
the circuit being measured. For DC current,
touch the red probe to the positive side of
the circuit and touch the black probe to the
negative side of the circuit.
8. Apply power to the circuit.
9. Read the current on the LCD display.
10A
MAX
MIN
10A
MAX
MIN
10A
MAX
MIN
MEASUREMENTS
UP TO
4000ÂľA AC/DC
MODE
MEASUREMENTS
UP TO
400mA AC/DC
MODE
MEASUREMENTS
UP TO 10A AC/DC
MODE
working on live circuits. Do not measure current on circuits
that exceed 600V. Measurements in the 10A range should
be limited to 30 seconds every 15minutes.
WARNING: Observe all safety precautions when
AC/DC Current Measurements
Frequency and % Duty Cycle Measurements
WARNING: Observe all safety precautions
when working on live live voltages.
Operation cont.
Operation
MODE
MODE
10A
10A
10A
MAX
MIN
MAX
MIN
MODE
16040T
MAX
MIN

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 10
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : 9c26cd5c-2a5d-11e6-0000-e2197cc7391d
Producer                        : GPL Ghostscript  9.0
Keywords                        : ()
Modify Date                     : 2016:06:01 15:06:29+01:00
Create Date                     : 2016:06:01 15:06:29+01:00
Creator Tool                    : PDFCreator Version 1.2.0
Document ID                     : 9c26cd5c-2a5d-11e6-0000-e2197cc7391d
Format                          : application/pdf
Title                           : User manual.pdf
Creator                         : ferry-al
Description                     : ()
Author                          : ferry-al
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AENI-16040T

Navigation menu