Ssd Company Limited Servo Drive 637F Users Manual

637f to the manual f5ff6d29-f62e-4d35-bcec-3e730436f6a4

2015-02-06

: Ssd-Company-Limited Ssd-Company-Limited-Servo-Drive-637F-Users-Manual-528609 ssd-company-limited-servo-drive-637f-users-manual-528609 ssd-company-limited pdf

Open the PDF directly: View PDF PDF.
Page Count: 89

DownloadSsd-Company-Limited Ssd-Company-Limited-Servo-Drive-637F-Users-Manual- Servo Drive 637f  Ssd-company-limited-servo-drive-637f-users-manual
Open PDF In BrowserView PDF
637f
Servo drive

Product
Manual
07-02-10-01-E-V0505.doc

Additional Supporting Documentation
UL:07-02-01
Product Manual Rack 6 U and EMV

UL:07-02-02-01
Product Manual Power Supply Plug-in Module NE B

UL: 07-02-09-02

Feedback System HIPERFACE®

UL:07-02-10-02
Product - Manual Safe Standstill SBT

UL:07-05-02-03
Product Manual SUCOnet K

UL:07-05-03-02
Product Manual Bus Interface CAN for 635 / 637 / 637+ / 637f

UL:07-05-04-02
Product Manual Bus Interface DP for 635 / 637 / 637+ / 637f

UL:07-05-05-02
Product Manual Bus Interface Interbus S for 635 / 637 / 637+ / 637f

UL:07-05-07-02
Product Manual I/O Interface for 635 / 637 / 637+ / 637f

UL:07-05-08-02
Product Manual Bus Interface Device Net for 635 / 637 / 637+ / 637f

________________________________________________________________________________________________________________________________________________________________________________________________________________________

2

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Additional Supporting Documentation
UL:07-09-04-02
Product Manual Suppression Aids EH

UL:10-06-03
Product Manual Serial Transfer Protocol
635 / 637 / 637+ / 637f EASY- Serial

UL: CD

UL:10-06-05

EASYRIDER® Windows - Software

Product Manual Software BIAS®

UL: 12-01
Product Manual Accessories - Plugs

UL:12-02
Product Manual Accessories - Cable

UL:12-03
Product Manual Ballast Resistors

©SSD Drives GmbH.
All rights reserved. No portion of this description may be produced or processed in any form without the
consent of the company.
Changes are subject to change without notice.
SSD Drives has registered in part trademark protection and legal protection of designs.
The handing over of the descriptions may not be construed as the transfer of any rights.

Made in Germany, 2005
________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

3

Table of Contents
Seite

The Most Important Thing First ........................................................................ 7
Safety Precation ................................................................................................. 8
1

General Information................................................................................ 10

1.1
1.1.1
1.1.2
1.1.3
1.1.4
1.2
1.2.1
1.2.2
1.2.3
1.3
1.3.1
1.3.2
1.3.3
1.3.4
1.3.5
1.3.6
1.4
1.4.1
1.4.2

System Description....................................................................................................................... 10
Digital Communication.................................................................................................................. 11
Operation configurations............................................................................................................... 11
Compatibility with 637 Servo Drives (Not required for new projects) ........................................... 12
Compatibility with 637+ Servo Drives ..........................................................................................12
Type Code ...............................................................................Fehler! Textmarke nicht definiert.
Combination possibilities for the various communications / I/O - modules .................................. 14
Layout module slots...................................................................................................................... 15
Layout of Power Board ................................................................................................................. 15
Range Data................................................................................................................................... 16
Insulation Concept ........................................................................................................................ 16
General Data................................................................................................................................. 16
Compact Units 637f/K D6R........................................................................................................... 17
Plug-In Modules 637f/D6R............................................................................................................ 18
Single- and Three-Phase Supply.................................................................................................. 19
Output Power ................................................................................................................................ 20
Dimensions ................................................................................................................................... 21
Dimensions for Compact Device and Plug-In Module.................................................................. 21
EMC-Clip (optional) ..................................................................................................................... 22

2

Connector Assignments and Functions .............................................. 23

2.1
2.1.1
2.1.2
2.2
2.2.1
2.3
2.3.1
2.4
2.4.1
2.4.2
2.5
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.6
2.6.1
2.6.2
2.7
2.7.1
2.7.2

General View of Connections for Compact Device 637f/ K D6R 02 – 10 .................................... 23
637f/K D6R 02...10 Width 14 HP .................................................................................................. 23
637f/K D6R 16...30 Width 20 HP .................................................................................................. 24
Connector Pin Assignments and Contact Functions .................................................................... 25
Power Connections for Plug-In Module 637f/D6R........................................................................ 25
Signal Connections....................................................................................................................... 26
Control Signal Plug X10 - SUB D25 Socket ................................................................................. 26
Feedback Sensor X30 .................................................................................................................. 29
Function module X300.................................................................................................................. 29
Feedback Sensor Connection X30 (SUB D 09 Socket) ............................................................... 30
Multi-function X40 ......................................................................................................................... 31
Incremental Output ....................................................................................................................... 32
Incremental-Input.......................................................................................................................... 32
Stepper Motor Input ...................................................................................................................... 33
Stepper Motor Input ...................................................................................................................... 33
SSI Encoder Interface................................................................................................................... 34
Digital Interfaces ........................................................................................................................... 35
Service Interface - COM1 (RS232)............................................................................................... 35
Fieldbus Interface - COM2............................................................................................................ 36
Option module RP SBT ................................................................................................................ 44
Safe Stop ...................................................................................................................................... 44
Brake control and PTC evaluation................................................................................................ 45

________________________________________________________________________________________________________________________________________________________________________________________________________________________

4

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Table of Contents
Seite

3

Operating modes .................................................................................... 46

3.1
3.2
3.3

Operating modes and pin functions.............................................................................................. 47
Configurable pin-functions (depending on the operating mode) .................................................. 48
Function diagrams from inputs and outputs ................................................................................. 49

4

Mechanical Installation .......................................................................... 50

4.1
4.2
4.3

Mounting ....................................................................................................................................... 50
Control cabinet - mounting............................................................................................................ 50
Cooling.......................................................................................................................................... 50

5

Electrical Installation.............................................................................. 51

5.1
5.2
5.3
5.4
5.4.1
5.5
5.6
5.7
5.8
5.8.1
5.8.2

Safety............................................................................................................................................ 51
The danger of electric shocks....................................................................................................... 51
Danger areas ................................................................................................................................ 51
Grounding, safety grounding ........................................................................................................ 51
Ground connections...................................................................................................................... 51
Short-circuit capability and discharge currents............................................................................. 51
Fuses, contactors, filters............................................................................................................... 52
Correction of supply current ......................................................................................................... 53
Brake resistor................................................................................................................................ 54
Selection of the brake resistor ...................................................................................................... 54
Configuration of the brake resistor ............................................................................................... 55

6

Wiring instructions ................................................................................. 57

6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.7.1
6.7.2
6.7.3

General Information ...................................................................................................................... 57
Control cabling .............................................................................................................................. 57
Power cabling ............................................................................................................................... 57
Installation of the rack................................................................................................................... 57
Analog setpoint ............................................................................................................................. 57
Safety rules ................................................................................................................................... 57
Electromagnetic compatibility (EMC)............................................................................................ 57
Hints for mounting......................................................................................................................... 58
Example for mounting................................................................................................................... 59
Achieveable specifications and conditions ................................................................................... 59

7

Setting and programming...................................................................... 60

7.1
7.2

Jumper .......................................................................................................................................... 60
Digital communication see: Chapter 13........................................................................................ 60

8

Commissioning....................................................................................... 61

8.1
8.2

Preparation ................................................................................................................................... 61
Commissioning in steps................................................................................................................ 62

9

Diagnose und Fehlersuche.................................................................... 65

9.1
9.2
9.3

7-segment display......................................................................................................................... 65
Reset of a regulator trouble .......................................................................................................... 69
Trouble shooting ........................................................................................................................... 70

10

Block circuit diagram ............................................................................. 71

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

5

Table of Contents
Seite

11

General Technical Data.......................................................................... 72

11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
11.10
11.11

Power circuit ................................................................................................................................. 72
Control circuit ................................................................................................................................ 72
Signal inputs and outputs, connection X10 .................................................................................. 72
Signal inputs and outputs, connection X120B resp. 120C ........................................................... 73
Digital control ................................................................................................................................ 73
Digitale communication................................................................................................................. 74
Resolver evaluation/transmitter principle...................................................................................... 74
Controllersystem........................................................................................................................... 74
Analog-Outps ................................................................................................................................ 75
Thermal data................................................................................................................................. 75
Mechanical data............................................................................................................................ 75

12

Disposal................................................................................................... 76

13

Software................................................................................................... 77

13.1
13.2

EASYRIDER® Windows - Software .............................................................................................. 77
SSD Drives programming language BIAS.................................................................................... 78

14

Certificates .............................................................................................. 81

15

Index ........................................................................................................ 86

16

Modification Record ............................................................................... 88

________________________________________________________________________________________________________________________________________________________________________________________________________________________

6

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

The Most Important Thing First
The Most Important Thing First

Thanks for your confidence choosing our product.
These operating instructions present themselves as an overview of the technical data and
features.
Please read the operating instructions before operating the product.
If you have any questions, please contact your nearest SSD Drives representative.
Improper application of the product in combination with dangerous voltage can lead to
injuries.
In addition, damage can also occur to motors or other products.
Therefore please observe our safety precautions strictly.
Safety precautions
We assume that, as an expert, you are familiar with the relevant safety regulations,
especially in accordance with VDE 0100, VDE 0113,VDE 0160, EN 50178, the accident
prevention regulations of the employers liability insurance company and the DIN
regulations and that you are able to use and apply them.
As well, relevant European Directives must be observed.
Depending on the kind of application, additional regulations e.g. UL, DIN are subject to be
observed.
If our products are operated in connection with components from other manufacturers,
their operating instructions are also subject to be observed strictly.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

7

Safety Precautions
Safety Precation

Attention

Digital servo drives, corresponding to EN 50178/VDE 0160, are power
electronic components utilized for the regulation of the flow of energy in
electrical power installations. They are exclusively designed and configured to
supply SSD Drives, or SSD Drives approved, servo motors. Handling,
installation, operation, and maintenance are only permitted under the conditions
of and in keeping with the effective and/or legal regulations, regulation
publications and this technical document.
The operator must make sure that these regulations are strictly followed.
The Concept of Galvanic Separation and Insulation:
Galvanic separation and insulation corresponding to EN 50178/VDE 0160,
provides for additional insulation protection.
In addition, all digital signal inputs and outputs are provided with a galvanic
separation utilizing either a relay or an optical coupler. In this way, an increased
level of protection against potential interference and a limitation of potential
damage due to incorrect connections are provided.
The voltage level must not exceed the designated low safety voltage of 60V
DC or 25V AC, respectively, in accordance with EN 50178/VDE 0160.
The operator must make sure that these regulations are strictly followed.

High Voltage!
Danger of Electrocution!
Life Threatening Danger!

Danger !

Caution !

Due to safety considerations and the product guarantee, the
operator is prohibited from opening the servo drive case. Service,
maintenance and repair of SSD Drives products should only be
carried out by specified representatives of the company. Expert
configuration and professional installation, as described by this
document, are the best way to insure for the problem-free operation
of the SSD Drives servo drive!

________________________________________________________________________________________________________________________________________________________________________________________________________________________

8

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Safety Precautions

Please
observe!

Pay Special Attention to the Following:
Permissible Protection Class: Protective Grounding - operation is only permitted
when the protective conductor is connected according to regulations.
The operation of servo drives is not allowed, under the sole use of a residual
current operated protective device as protection against indirect touching. The
servo drive may only be used in the rack or in its compact enclosure.
Furthermore the regulator is designed solely for control cabinet operation.
Work on or with the servo drive may only be carried out with insulated tools.
Installation work may only be done in a de-energized state. When working on
the drive, one should not only block the active – input, but also separate the
drive completely from the main power connection.
CAUTION - Risk of Electrical Shock:
Wait 3 minutes after switching the component off, to allow the capacitors to
discharge.
Screws sealed with varnish fulfill an important protection function and may not
be moved or removed.
It is prohibited to penetrate the inside of the unit with objects of any kind.
Protect the unit from falling parts, pieces of wire, metal parts, etc., during
installation or other work in the control cabinet. Metal parts can lead to
a short-circuit in the servo drive.
Before putting the unit into operation, remove additional covers so that the unit
does not overheat. With measurements at the servo drive it is absolutely
necessary to observe the potential separation

SSD Drives GmbH is not liable for damages which may occur when the
instructions and/or the applicable regulations are not explicitly observed!

Stop !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

9

1

General Information

1

General Information

1.1

System Description
th

The 5 generation of the digital servo drive serves to regulate the current, speed and position of
AC servo motors, (standard: with resolver)
All control circuits and functions are realized digitally.
System variants

Rack - version: 637f/D6R....

Compact - version: 637f/K D6R....

R

Su pply volta ge:

AC

1* oder 3 *230 VAC/50..60 Hz
3* 400... 460VA C/50 ..60H z

R

637f/ K D6R

Su pply volta ge:

AC

1* oder 3 *230 VAC/50..60 Hz
3* 400... 460VA C/50 ..60H z

DC

Us 24VDC

637f/ K D6R

DC

Us 24VDC

M

M

Servodrives
Power supply unit

Rack, R6
or
R6 EM V

Power supp ly
p lug -in module
NE B

Servodrive

Fan

Fan

Explanations for the rack and power supply modules are documented in separate descriptions.
If required, the returned braking energy can be drawn off into additional external ballast resistors.
The AC-supply voltage is fed directly or via transformer to the associated power supply module.
The devices are designed to be operated on networks which are grounded at the
centre point (TN networks) !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

10

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information

1

System Description
1.1.1

Digital Communication

Diagnostics / Setup
General:
by 7 segment display
Comfortable: via PC with EASYRIDER® Windows – Software from version V8.xx
(serial interface RS232)
Communication
The serial-communication-protocol is open and fully documented.
(Explanation see separate documentation)
Every user has unrestricted access to all functions and parameters.

⌧

EASYRIDER

⌧

customer-made software

⌧

PLC So ftware

1.1.2

637f
current-loop
speed-loop
position-loop

PLC

X10

PLC, binary selectionl,+/- 10V

instructions

COM 1
RS232
COM 2
RS23 2
RS42 2
RS48 5
CAN-BUS 1
CAN-BUS 2
SUCOnet K
Profi bus DP
Inter bus S
DeviceNet

setup

diagnostics

⌧ programming

Operation configurations

There are opportunities ranging from simple current and speed control to programmable position control
processes (PLC), supported by the 1500 BIAS command blocks.
"BIAS" User shell for intelligent drive controls
see:
chapter 3
Operating modes
chapter 13.2 BIAS commands
chapter 13.3 Extended BIAS commands

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

11

1

General Information
System Description

1.1.3

Compatibility with 637 Servo Drives (Not required for new projects)

The 637f series servo drives are essentially pin- and functionally compatible with the servo drives 637.
However, when a servo drive 637 is replaced with a 637f drive, the existing application must be checked and
carefully tested to determine compliance under the corresponding safety precautions.
The following points should be checked in any case and eventually be adjusted before the function test:
1. Motor direction parameter and limit switch setting (see release note V6.12)
2. Position setpoints and comparison values have to be quadrupled, resp. sixteenfold
(low encoder resolution at 637)
3. Coupling factors in synchronous applications have to be quadrupled, resp. sixteenfold
(low encoder resolution at 637)
4. Execution of BIAS- and PLC programs is 2.25 times quicker than with the 637. This can cause timing
problems with improper programming (e.g. wait times with NOPs)

1.1.4

Compatibility with 637+ Servo Drives
(Not required for new projects)

Der Servoregler 637f ist voll funktionskompatibel zu 637+
Funktion
PC-Operating-Software

637

637+

®

EASYRIDER DOS Version
or Windows Version

PC-Connection-Cable
see: chapter 2.6.2.3
Power Part, Power Data and
Power Connectors
Control Singals, Connector X10
see: chapter 2.3.2
Analog Set Point X10.5/18,
Resolution
Resolver Signals, Connector X30
see: chapter 2.4.2
Feedback – Interface - Module
X300
see: chapter 2.4.1
Multifunction, Connector X40
see: chapter 2.5
Interface, Connector COM2
see: chapter 2.6.2 – 2.6.2.9
Options Module
see: chapter 2.6.2 – 2.6.2.10
Operating Modes, BIAS –
Functions
see: chapter 3 and 13.2
PROG-Key
Analog-Output - Test Signals
MP1/MP2:
> connector X 10
> Front Test Sockets
Technical Data
Analog Out
MP1 / X10.17
MP2 / X10.6
Control Loops
see: chapter 11.5

Control Loop Parameters
Jumper
see: chapter 7.1

637f
®

EASYRIDER®
Windows Version V8.xx
PC - SUBD-9 to
4-pin module connector (COM1)
equal

EASYRIDER
Windows Version

PC - SUBD-9 to
LEMO connector (COM1)

equal pinning and function
12 bits

14 bits

pin–compatible
12/14 Bit Resolution
-

extended functionality
16 Bit Resolution
HIPERFACE
-

compatible

SIN / COS
extended functionality

extended functionality
CAN BUS 2, RP_2Cx
extended functionality
RP_SBT
future extensions possible
position value 16 bit ≈ 1 revolution

equal
equal
command set compatible
position value
12/14 bits ≈ 1revolution
present

not available
X 10.6 / X 10.17

yes

no

7 bits , Rout = 10 kOhm
7 bits , Rout = 10 kOhm

8 bits , Rout = 1.8 kOhm
10 bits , Rout = 1.8 kOhm
performance boost
performance boost as
compared to 637f:
compared to 637:
cycle time for speed twice as
cycle time twice as fast
fast,
position eight times as fast
Generally compatible,
possible optimization required
JP2.2, JP2.3, JP2.7, JP2.8

________________________________________________________________________________________________________________________________________________________________________________________________________________________

12

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information
1.2

1

Modle code
standard

marking
type:

637f/

optional

a

b

c

d

e

f

g1

g2

h

i

X

D6R

XX

.S5

-X

-X

-XXX

-XXX

-XXx

-XXX

marking
a
b
c

d
e

f

special

description
XXXX/
K
0
D6R

=
=
=
=

02
04
06
10
16
22
30
.S5

=
=
=
=
=
=
=
=

-3
-7
-E
-0

=
=
=
=

-000
-232
-422
-485
-CAN

=
=
=
=
=

637f ≅ SSD Drives-fast-design
1-axis-compact digital-servo drive system
design plug-in device
Digital 6U drive
Rated current:
2 amps
4 amps
6 amps
10 amps
16 amps
22 amps
30 amps
Digital servo drive 5th generation
Intermediate circuit rated voltage:
325V (230V AC) 16..30A only as rack system possible
650V (460V AC)
With EMC-Clip unit
Without EMC-Clip unit
additional option modules on the drive for communication via COM2
None option
RS 232 interface
≅ slot A (B)
RS 422 interface
≅ slot A (B)
RS 485 interface
≅ slot A (B)
CAN – Bus
≅ slot A (B)

-2CA
-2C8
-DEV
-SUC
-PDP
-IBS

=
=
=
=
=
=

2 x CAN (without I/O’s)
2 x CAN + 4 outputs and 4 inputs
CAN - Bus / DeviceNet
SUCOnet K
Profibus DP
Interbus S
(Attention: changed front plate)

-EA5

=

I/O interface (5 inputs, 2 outputs)

≅ slot B (A)

changed front plate)

g1

≅ slot B (A) / [C*]
≅ slot B (A) / [C*]
≅ slot B (A)
≅ slot B (A)
≅ slot B (A)
≅ slot B (A)

-000
-EAE
-SBT

=
=
=

-RD2

=

-HF2
-SC2

=
=

additional option modules on the drive via X200 (Attention:
No Options
I/O interface (14 inputs, 10 outputs)
Safety – Board Module
X300 – Function module
Standard X30 Resolver module 2nd version
HIPERFACE module 2nd version
Sinus / Cosinus - module 2nd version

=
=
=
=
=

Entry only at use
Special - resistance - setting
Broad-band contact X10.7 - X10.8
Protection moisture condensation
Protection moisture condensation + Broad-band contact X10.7 - X10.8
Jumper 209 / 2 - 3 open , by SBT - Option Thermo - Contact X30 (PTC / NTC)

g2

h

i
-Sxx
-X7x
-BSx
-B7x
-923

≅ slot C
≅ slot C
≅ slot D
≅ slot D
≅ slot D

at assignment [C] Interface you can used 1 x CAN *

Typical Example
A typical example of an order of a 1-axis compact device in SSD Drives design:

Type:

a
637f/

b
KD6R

c
02

d
.S5

e
-3

f
-0

g1
-2CA

g2
-EAE

h
-RD2

i
-

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

13

1

General Information
Modle Code

1.2.1

Combination possibilities for the various communications / I/O - modules

Slots
A
B
C
Option modules
232 422 485 CAN 2CA 2C8 DEV SUC PDP IBS EA5 EAE SBT *2CA *2C8
Type Codel
637f/xD6Rxx.S5-x-x-232-000-xxx
637f/xD6Rxx.S5-x-x-232-EAE-xxx
637f/xD6Rxx.S5-x-x-232-SBT-xxx
637f/xD6Rxx.S5-x-x-232-2CA-xxx
637f/xD6Rxx.S5-x-x-232-2C8-xxx
637f/xD6Rxx.S5-x-x-422-000-xxx
637f/xD6Rxx.S5-x-x-422-EAE-xxx 637f/xD6Rxx.S5-x-x-422-SBT-xxx 637f/xD6Rxx.S5-x-x-422-2CA-xxx
637f/xD6Rxx.S5-x-x-422-2C8-xxx
637f/xD6Rxx.S5-x-x-485-000-xxx
637f/xD6Rxx.S5-x-x-485-EAE-xxx 637f/xD6Rxx.S5-x-x-485-SBT-xxx 637f/xD6Rxx.S5-x-x-485-2CA-xxx
637f/xD6Rxx.S5-x-x-485-2C8-xxx
637f/xD6Rxx.S5-x-x-CAN-000-xxx 637f/xD6Rxx.S5-x-x-CAN-EAExxx
637f/xD6Rxx.S5-x-x-CAN-SBT-xxx 637f/xD6Rxx.S5-x-x-2CA-000-xxx
637f/xD6Rxx.S5-x-x-2CA-EAE-xxx 637f/xD6Rxx.S5-x-x-2CA-SBT-xxx 637f/xD6Rxx.S5-x-x-2C8-000-xxx
637f/xD6Rxx.S5-x-x-2C8-EAE-xxx 637f/xD6Rxx.S5-x-x-2C8-SBT-xxx 637f/xD6Rxx.S5-x-x-DEV-000-xxx 637f/xD6Rxx.S5-x-x-DEV-EAE-xxx 637f/xD6Rxx.S5-x-x-DEV-SBT-xxx
637f/xD6Rxx.S5-x-x-SUC-000-xxx
637f/xD6Rxx.S5-x-x-SUC-EAE-xxx
637f/xD6Rxx.S5-x-x-SUC-SBT-xxx 637f/xD6Rxx.S5-x-x-PDP-000-xxx 637f/xD6Rxx.S5-x-x-PDP-EAE-xxx 637f/xD6Rxx.S5-x-x-PDP-SBT-xxx 637f/xD6Rxx.S5-x-x-PDP-2CA-xxx 637f/xD6Rxx.S5-x-x-PDP-2C8-xxx 637f/xD6Rxx.S5-x-x-IBS-000-xxx
637f/xD6Rxx.S5-x-x-IBS-EAE-xxx 637f/xD6Rxx.S5-x-x-IBS-SBT-xxx 637f/xD6Rxx.S5-x-x-EA5-000-xxx
637f/xD6Rxx.S5-x-x-EA5-EAE-xxx 637f/xD6Rxx.S5-x-x-EA5-SBT-xxx 637f/xD6Rxx.S5-x-x-000-EAE-xxx 637f/xD6Rxx.S5-x-x-000-SBT-xxx -000 = none option

Example:
637f/xD6Rxx.S5-x-x-232-EAE-RD2
…
-232
…
-EAE
…
-RD2

possible combination

at assignment [C] Interface you can used 1 x CAN *

= on slot A
= on slot C
= on slot D (Motor - Feedbacksystem)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

14

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information

1

Modle Code
1.2.2

Layout module slots
Module slots:
A

-232
-422
-485
-CAN

B

-2CA
-2C8
-DEV
-SUC
-PDP
-IBS
-EA5

C

-EAE
-SBT
*-2CA
*-2C8

Motor - Feedbacksysteme:
-RD2: Standard resolver
D
-HF2: Option HIPERFACE®
-SC2: Option rotor position transmitter
* kann nur 1 mal CAN verwendet werden

Note: The option modules of the slots A / B / C can only be reached after removing the cooling plate.

1.2.3

Layout of Power Board
View solder side (solder jumper)
JP2.8
JP2.3
JP2.7
JP2.2
JP101. 1/ 2/ 3
JP102 1/ 3/ 2
JP100 2/ 3/ 1
JP1 1/ 3/ 2
JP2 2/ 3/ 1
JP3 1/ 3/ 2
JP4 2/ 3/ 1
JP209. 1/ 2/ 3

Solder jumper function
see: Chapter 7.1

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

15

1

General Information

1.3

Range Data

1.3.1

Insulation Concept
COM1

power - terminals

customer part

COM2

dep. Optionsmodule

L1, L2, L3

Remote IN

DC-bus
M1, M2, M3

X10
analog

brak - cirquit

X10
digital
X30 1)
GND

X40

Us

power supply
DC 24 V

DC 24 V

AC

L1
N

PE
double insulation VDE 0160
Insulation of control voltage supply
Take Care ! The insulation of control (Com1..X40) depends on the insulation of control voltage supply
Required for safe separation (PELV): double insulation
Additional insulation via opto-coupler or relay (without Safety-Functions)
1)

1.3.2

see additional hints, chapter 2.4.2

General Data

Enclosure Rating for Mounting in a Cubicle
Operating Temperature Range
Storage Temperature Range
Air Pressure
Humidity
Operating Temp
Reduced Operation
De-rating of the Output Current
Altitude h
Reduced Operation
De-rating of the Output Current
Safety Over Voltage - Category of Power Circuit
Pollution Degree - for Mounting in a Cubicle
Vibration Test in Accordance with
DIN IEC 68-2-6, Test FC
Condition for Testing
Frequency Range
Amplitude
Acceleration
Test Time per Axis
Frequency Sweep Speed

IP20

1)

1)

EN 50178 / VDE 0160, class 3K3
-25°...+55° C
86 kPa - 106 kPa
5% - 85%, 40°C
0...40°C
>40°...< 50°C
2% /°C
h ≤ 1000m
h > 1000...≤ 4000m
1% / 100m
EN 50178 / VDE 0160, UL, cUL III,
VDE / UL: 2

10...57Hz 57...150Hz
0,075 mm
1g
10 sweep cycle
1 octave/min
1)

Use only fan-cooled devices. For reduced operating
conditions, no UL approval is available.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

16

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information

1

Range Data
1.3.3

Compact Units 637f/K D6R

Compact Units

637f /

Input
Supply Voltage
50..60 Hz

Phases
Supply Peparation
Power-On Current
Limit
Control Voltage
Control Current
incl. Fan
Output
Sine-Wave Voltage
at Un
De-rating of Unr
Rated Current RMS
Max. Current RMS
Time for Imax
Min. Motor
Inductance
(terminal / terminal)
Brake Circuit
Setpoint DC

min.
Un
max.

[V]
[V]

K D6R 02
.S5
-3
-7

K D6R 04
.S5
-3
-7

230

460

230

460

1;3

3

1;3

3

4)

[V]
[A]

Unr

[Veff]

Lph/ph

Ub

460

K D6R 10
.S5
-3
-7

K D6R 16
.S5
-7

K D6R 22
.S5
-7

K D6R 30
.S5
-7

460

460

460

14
230 460
+ 10%

1;3
3
Fuses, contacts, filters see chapter 5.6

NTC 4 Ohm

Us
Is
DC

Inr
Imaxr
min.

230

toleranc
e

model
1)

K D6R 06
.S5
-3
-7

NTC 2 Ohm

21,5....24....29, attention: insulation-concept chapter 1.3.1
Continuous: max. 1,2A Power-On-Peak:
Continuous: max 1,5A Powernom. 3A; max.. 6A / 0,8 mS, 2,5A / 25 mS
On-Peak: nom. 3A;
max. 6A / 0,8 mS, 3A / 25 mS
220

[A]
[A]
Sec

447

2
4
5

220

447

220

447

220 447

447

447

447 3)

depending upon load and single or 3-phase supply. (see chapter 1.3.5)
4
6
10
16
22
30 3)
8
12
20
32
44
60
5
5
5
5
5
5

[mH]

6,0

12,0

3,0

6,0

2,0

4,0

1,2

2,4

2,0

1,1

0,8

[V]

375

730

375

730

375

730

375 730

730

730

730

29,0

34,8

34,8

Max. Power

Pbmax

[kW]

4,5

8,7

4,5

8,7

6,7

13,0 11,2 21,
7

Continuous Power

Pbnenn
Rbint
Pd
Pmax

[W]
[Ω]
[W]
[kW]

100
30
1,4

300
30
1,7

100
30
1,4

300
30
1,7

100
30
1,4

300
30
1,7

≤ 560
100 300
30 30
1,4 1,7

Rbextmi
n

[Ω]

47

82

47

82

27

47

15

27

20

15

15

[W]

29

29

29

29

29

29

29

29

36

36

36

Internal Resistor

Min. External
Resistor
General
Power Loss
Fan, Electronic

2)

------

PE loss

Fan Models
24V DC

2 Piece L 024 / (12TE * 25)
1 Piece L 024 / (12TE * 15)

[V]

Power Stage per A
Weight
Additional Data

[W/A]
[kg]

9

12

9

12
9
5,0

12

9

12

2 Piece L 024 / (16TE x 25)
1 2 Piece L 024 /
(16TE x 20)
12
12
12
8,8

see: chapter 11
1)
2)
3)
4)

Suggested: transformer-based supply
Use only SSD Drives-released types
Max. continuous performance reduced to 80%, see chapter 1.3.6
References chapter 1.3.6

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

17

1

General Information
Range Data

1.3.4

Plug-In Modules 637f/D6R

Plug-In Modules

637f/

Input
DC-BUS Rated

Control Voltage
Control Current

1)

2)

Fan
Output
Sine-Wave Voltage
at Un
De-rating of Unr
Rated Current RMS
Max. Current RMS
Time for Imax
Min. Motor
Inductance
(terminal / terminal)
Brake-Circuit
Setpoint DC
Continuous Rating
Min. External
Resistor
General
Power Loss
Electronic
Output Stage per A
Weight
Additional Data

2)

D6R 04
.S5
-3
-7

D6R 06
.S5
-3
-7

min.
Ug
max.
Us
Is
DC
Typ

tolerance
[V]
[A]

Unr

[Veff]

Inr
Imaxr

[A]
[A]
min.

Lph/ph

[mH]

6,0

12,0

3,0

6,0

2,0

Ub

Max. Power

[V]
[V]

D6R 02
.S5
-3
-7

325

D6R 10
.S5
-3
-7

D6R 16
.S5
-3 -7

D6R 22
.S5
-3
-7

D6R 30
.S5
-3
-7

20
325 650 325 650 325 650 325 650
+ 10%
24V DC +20% -10%, attention: insulation-concept chapter 1.3.1
Continuous: max 0,8A Power-On-Peak: nom. 2A; max 5A / 0,8 mS, 2A / 25mS
650

325

---

L220
K

---

220

447

220

2
4
5 Sec

650

325

650

L220K

447

220

447

L220G

220

447

220

447

220

447 220 447 3)

depending on load and single or 3-phase supply (see chapter 1.3.5)
4
6
10
16
22
30 3)
8
12
20
32
44
60
5 Sec
5 Sec
5 Sec
5 Sec
5 Sec
5 Sec
4,0

1,2

2,4

1,0

2,0

0,55

1,1

0,4

0,8

375

730

375

730

375

730

375

730

[V]

375

730

375

730

375

730

Pbmax

[kW]

4,5

8,7

4,5

8,7

6,7

13,0 11,2 21,7 15,0 29,0 18,0 34,8 18,0 34,8

Pbnenn

[W]

Rbextmin

≤ 560

[Ω]

33

63

33

63

22

43

12

24

10

20

8,2

15

8,2

15

[W]
[W/A]
[kg]

20
9

20
12

20
9

20
12

20
9

20
12

20
9

20
12

20
9

20
12

20
9

20
12

20
9

20
12

PE loss

1,5

4,0
see chapter 11

1)
2)
3)
4)

Suggested: transformer-based supply
Use only SSD Drives-released types
Max. continuous performance reduced to 80%, see chapter 1.3.6
References chapter 1.3.6

________________________________________________________________________________________________________________________________________________________________________________________________________________________

18

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information

1

Range Data
1.3.5

Single- and Three-Phase Supply

Due to the line-ripple of the DC-Bus, the rate of usable output voltage is reduced as follows.
This reduction affects the maximum attainable speed of the applied motor.
Three-phase supply:
The unloaded output voltage will be reduced to approx. 90%, maximally 85
%

Single-phase supply: 50 – 60 Hz
only servo drive 637f / ..02 up to 06
see the following diagram:

Derating of servo drive output voltage in case of single-phase operationen
Output current [ARMS]

12
10
8
6
4
2
0

0

20

40

60

80

100 [%]

Output voltage in % of unloaded condition

Hint for parameterization:
To avoid unexpected tripping of the under voltage threshold, the parameter setting should be left on
default values (EASYRIDER® Windows – Software).
Required motor-terminal-voltage for specified speed.

Approximation: (up to 3000RPM)
Ukl = 1,2 * (EMF * n / 1000) + I * (Rph + RL) [V]

Ukl
EMF
Rph
RL
I

Required motor voltage [V RMS]
Back-EMF of motor [V RMS] / 1000 RPM
Resistance of motor (between terminals) [Ω]
Line resistance of motor cable [Ω]
Motor-current [A RMS]

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

19

1

General Information
Range Data

1.3.6

Output Power

In case of continuous operation in the full-load range, the limits as shown in the following diagram
need to be respected.
Typical servo applications are not affected by this restriction. (S3 operation: Start/Stop).

________________________________________________________________________________________________________________________________________________________________________________________________________________________

20

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Information
1.4

Dimensions

1.4.1

Dimensions for Compact Device and Plug-In Module

1

Ø 5,2
fro nt side

A
B
C

D

detail

18
D

d

Ø 10
243
220

400
262
386

plug -in modu le

233

304

spa ce for fan
a

Ø 5,2

d

1,6
280

detail

9

5,2

A
B
C
D
a

637f/K D6R 02...10
65,0 mm
60,0 mm
30,0 mm
14,5 mm
40,2 mm

width
14 HP

8 HP

637f/K D6R 16...30
104,6 mm
100,0 mm
71,0 mm
14,5 mm
80,4 mm

width
20 HP
1 HP ≈ 5,08mm
16 HP

Important Note:
You will need additional space on the front side, of approx. 70 mm, for the signal mating plugs!

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

21

1

General Information
Dimensions

1.4.2

EMC-Clip (optional)

1.4.2.1 For 8 HP Drive

side view

front view

1.4.2.2 For 16 HP Drive

side view

front view

EMC - Clip for
Feedback cable
(e.g. Resolver)
Mains cable
Motor cable

1
2
3

Meaning:
1,2,3 = cage clamp terminals

________________________________________________________________________________________________________________________________________________________________________________________________________________________

22

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

2

Connector Assignments and Functions

2.1

General View of Connections for Compact Device 637f/ K D6R 02 – 10

2.1.1

637f/K D6R 02...10 Width 14 HP

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

23

2

Connector Assignments and Functions
General View of Connections for Compact Device 637f/ K D6R 02 – 10

2.1.2

637f/K D6R 16...30 Width 20 HP

________________________________________________________________________________________________________________________________________________________________________________________________________________________

24

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions
2.2

Connector Pin Assignments and Contact Functions

2.2.1

Power Connections for Plug-In Module 637f/D6R

2

(at the rear of the rack)
(H15 multiple pin strip according to DIN 41612)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

25

2

Connector Assignments and Functions

2.3

Signal Connections

2.3.1

Control Signal Plug X10 - SUB D25 Socket

Complete Representation X10

Reference to pin 22 & pin 23: With controllers with option module SBT, kindly note the extended
functions of these signals (see documentation 07-02-10-02-E-Vxxxx).

________________________________________________________________________________________________________________________________________________________________________________________________________________________

26

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Signal Connections
Control Signal Plug X10 - SUB D25 Socket
Connection Example
(without option SBT)

drive side

control signal plug X10
model: SUB D 25
spread out

PLC
+/- 10V

14

1

15

2

16

3

17

4

18

5

19

1)

output ready

20

0V reference point, I/O-supply
input active

21

1)

N

8

10

23
11

-

24

spread out

25

2)
L1

7

9
22

24V 0V

+

6

12
13

+24V, I/O-supply

~
=
PELVisolation
mecanical
limit switches

L1

2)

~
=

+24V (br)
0V (br)

V1

N Supply may be used for mutliple brakes

Brake-Connection Type A :
when Isolation-Type of Break - Installation is
Basic (not PELV). The PELC - Isolation of
Control - Cirquits is uneffected.

K1

option: brake
Eurotherm
AC-Servomotor

3~

V1: Varistor e.g.. Siemens Q69X3431, 38V DC
K1: Couple-relais min. 2A,/60VDC PELV Isolation

option: brake

X10.23

X10.9

Brake-Connection Type B :
when isolation-type of break - installation is
PELV.

AC-Servomotor

3~

1) Security- and supervising logic, to be programmed by user !
2) IMPORTANT:
The power-supply for the motor-brake has to be adapted to the type of brake.
Voltage-Drops caused by long cables also may effect malfunctions of the brake.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

27

2

Connector Assignments and Functions
Signal Connections

Control Signal Plug X10 - SUB D25 Socket
Inputs / Outputs
Control Signal Plug X10
PIN
X10
1
2
3
4
5
6

7

8
9
10
11
12
13
14
15
16
17
18

19
20
21
22
23
24
25

function

type

description

shield connector
configurable (chapter 3)
stabilized auxiliary voltage
-12VDC; max. 80 mA
configurable (chapter 3)

shield
OPTO input
output auxiliary voltage

configurable (chapter 3)
configurable (chapter 3)
stabilized auxiliary voltage
+12V DC; max 80 mA
actual speed value monitor,
scalable
nominal speed value;
scalable differential
referenced to X10.5
Setting of the current limit
can be activated and scaled
(0..+10V for 0.. Imax)
configurable (chapter 3)
Nominal: 24V DC
H = output stage is active
L = output stage inactive
configurable (chapter 3)
configurable (chapter 3)
configurable (chapter 3)

OPTO Input
OPTO Input
output auxiliary voltage

OPTO input
analog input
reference point to X10.18
0...+-10V
Ri = 10 kOhm
Current monitor can be scaled
MP2 analog output,
in the speed controller menu
0…+-10V
via JP100 (solder jumper)
Optional
can be assigned as free and
loopable potential of the
READY contact
ON: regulator without fault
Relay Output
OUT: regulator fault or
fixed: ready
supply voltage off
Reference point for digital
Reference point for digital inputs
inputs
Reference potential for
Ground
analog signals
configurable (chapter 3)
OPTO Input
configurable (chapter 3)
OPTO Output
configurable (chapter 3)
OPTO Output

MP1 analog output,
0…+-10V
Analog input
0...+-10V / Ri = 10 kOhm
analog input
0..+10V
Ri = 10 kOhm
OPTO Output
Supply for outputs
OPTO input
fixed: active
Relay output
OPTO input
OPTO input

Data of the digital inputs and outputs see chapter 11 General technical data
Reference to Pin 22 & Pin 23: With controllers with option module SBT, kindly note the extended
functions of these signals (see documentation 07-02-10-02-E-Vxxxx).

________________________________________________________________________________________________________________________________________________________________________________________________________________________

28

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions
2.4

2

Feedback Sensor X30

The Feedback system generates a digital value, representing the rotor position
Derivated from this value:
commutation according to pole pair number
actual speed value
position value for position control

2.4.1

Function module X300

The connector X30 is directly related to the function module X300. This plug-in module
(see chapter 1.4.3.1) determines the type of usable Feedback system.
Thus the 637f drive system gets flexibility and is adaptable to future requirements.

Types X300
X300_RD2
X300_HF2
X300_SC2
Further types on reques

Description
Standard Resolver
Option HIPERFACE®
Option Sinus/Cosinus

Plug and Play
The 637f identifies the type of the module X300.
The EASYRIDER® Windows – Software loads the correct function code.
You follow the instructions in the EASYRIDER® Windows – Software.
At function module RD2 the function code is already installed (factory default).

Note:

With application of the function module X300_HF2 (HIPERFACE®) please observe
documentation 07-02-09-02-E-Vxxxx.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

29

2

Connector Assignments and Functions
Feedback Sensor X30

2.4.2

Feedback Sensor Connection X30 (SUB D 09 Socket)
Pinning of Motor - Feedback - Socket X30 with:
Resolver Module X300_RD2 (Standard Module)
Module: X300_RD2
PIN
X30
1
2
3
4
5
6
7
8
9

Function
shield
PTC optional
cos +
sin +
carrier +
PTC optional
cos sin carrier -

HIPERFACE® - Module X300_HF2
Module: X300_HF2
PIN
X30
1
2
3
4
5
6
7
8
9

Function
GND
10 VDC
cos +
sin +
data ref cos
ref sin
data +

Sinus / Cosinus - Module X300_SC2
Module: X300_SC2
PIN
X30
1
2
3
4
5
6
7
8
9

Function
GND
5,5 V
cos +
sin +
zero pulse +
ref cos
ref sin
zero pulse -

________________________________________________________________________________________________________________________________________________________________________________________________________________________

30

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions
2.5

2

Multi-function X40
Description of the X40:
Via a programmable I/O processor, the X40 connection can be configured differently.
EASYRIDER® Windows - Software
Standard functions:
- Incremental output
- Incremental input
- Stepper motor - pulse inputs
- SSI interface

The unobstructed configurability provides ideal conditions for synchronous applications.
General data
plug type:
maximum input or output frequency:
maximum cable length connected to galvanical
insulated terminals
(Encoder, controls)
maximum cable length connected to groundrelated terminals (other drives, controls)
maximum number of signal inputs to one as
incremental-output configured device
output signals:
differential logic level:
nominal range:
input signals:
differential input level:
nominal signal difference:
current consumption:

X40
SUB D 09 male plug
200 kHz
25 m; for extended distances please contact our
engineer
2 m, take care for good common grounding !
8
driver model MAX483 or compatible, RS422
L ≤ 0,5V
H ≥ 2,5V
0,0 ... 5,0V
150mA max.
receiver model MAX483 or compatible, RS422
diff min = 0,2V
1,0V
1...4 mA (depending on frequency)

Notice:
Master / Slave operation
1 Master, maximum 8 Slaves
Condition: Devices directly side by side !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

31

2

Connector Assignments and Functions
Multi-function X40

2.5.1

Incremental Output
EASYRIDER® Windows - Software X40 Mode = 0
Incremental encoder simulation for processing in positioning modules
Standard: 1024 increments
pulse duty cycle
further selectable pulse numbers: 2048, 512, 256, 128, 64, 4096
Inr. I/O X40
PIN
X40
1
2
3
4
5
6
7
8
9

Function

Designation

Channel B
Channel B inverted
Shield connector
Channel A
Channel A inverted
Reference *

B
/B
Shield
A
/A
GND
/Z
Z
+ 5 VDC

Channel Z inverted zero impulse
Channel Z, zero impulse
Supply voltage output max. 150 mA

Design Rule:
The input frequency range of the connected control must meet at least the value
of pulse output frequency on X40.

n = max. speed (rpm)
x = increments e.g. 1024
f = output frequency at X40.1,2,4,5

Formula: f = 1,2 * (n * x) = [Hz]

60

Example: n = 4000 1/min

f=
2.5.2

1,2 * (4000 * 1024)
= 81920 Hz
60

Incremental-Input

EASYRIDER® Windows - Software X40 Mode = 1
Parameter range of the input signals: 10...1000000 increments
Figure:

Note:
The operation of incremental encoders via long cables may cause a voltage drop of the encoder power
supply. We recommend the use of a separate voltage supply if necessary.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

32

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Multi-function X40
2.5.3

Stepper Motor Input
pulse / direction
EASYRIDER® Windows - Software X40 Mode = 2
Inr. I/O X40
PIN
X40
1
2
3
4
5
6
7
8
9

2.5.4

Function

Designation

Output: Drive active inverted
Output: Drive active
Shield connector
Pulse inverted
Pulse
Reference potential (generally to connect)

/READY
READY
Schield
/P
P
GND

Direction inverted
Direction
Supply voltage output max. 150 mA

/R
R
+5 VDC

Stepper Motor Input
pulse positive / negative
EASYRIDER® Windows - Software X40 Mode = 3

Figure: Puls / Richtung

Figure: Puls positiv / negativ

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

33

2

Connector Assignments and Functions
Multi-function X40

2.5.5

SSI Encoder Interface
EASYRIDER® Windows - Software X40 Mode = SSI_13 bit Singleturn
EASYRIDER® Windows - Software X40 Mode = SSI _14 bit Singleturn
EASYRIDER® Windows - Software X40 Mode = SSI_25 bit Multiturn
(13 bit Single- / 12 bit Multiturn)
EASYRIDER® Windows - Software X40 Mode = SSI_26 bit Multiturn
(14 bit Single- / 12 bit Multiturn)
Inr. I/O X40
PIN
X40
1
2
3
4
5
6
7
8
9

Function

Designation

Serial data from SSI encoder,
GRAY code up to 26 bit inverted
Serial data from SSI encoder,
GRAY code up to 26 bit
Shield connector
Clock output, inverted
Standard frequenzy: 179 kHz
Clock output
Standard frequenzy: 179 kHz
Reference potential

/DATA

Schirm
/TAKT

do not connect
do not connect
Supply voltage output max. 150 mA
If other data required:
a) Use of X300 module
b) External supply

+5 VDC

DATA

TAKT
GND

TAKT and /TAKT twisted pair
DATA and /DATA twisted pair
Cable screened, screen grounded at both sides,
max. cable length: 200m
Note:
For further information about SSI (Synchronous Serial Interface),
please refer to the documentations of appropriate suppliers.
(e.g.: Comp. Sick or Hengstler)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

34

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions
2.6

Digital Interfaces

2.6.1

Service Interface - COM1 (RS232)

2

Standard
Functions:
Supporting all diagnosis and setup tasks
Connection to your PC is made with the
SSD Drives communication cable KnPC/D
Communication is made via the SSD Drives operating program
(EASYRIDER® Windows - Software)

Com 1 RS232

Function drive side
PIN

RS232 PC side
PIN

4-pin modular jack

RXD
TXD
GND

Type Code
Kn PC 637f / 631-03.0
Kn PC 637f / 631-05.0

1
2
3
4

Länge
3m
5m

Receive serial data
Transmit serial data
do not connect
GND

3
2

TXD
RXD

5

GND

Beschreibung
PC-side, Sub D 09-plug
Drive side, 4-pin RJ 10-plug

Note:
The service interface RS232 is not galvanically isolated and should not be planned for this reason as an
operating interface ("hard-wiring")!
The mains connection of the PC must be made closed to the drive, to achieve a common ground.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

35

2

Connector Assignments and Functions
Digital Interfaces

2.6.2

Fieldbus Interface - COM2
Option modules SUB D09 socket

Many different functions can be implemented by optional using of the option modules.
Funktionen realisiert werden. Layout - see chapter 1.2.3
Overview:
module designation

interface

RP 232

galvanic isolation

design

slot

RS 232

-

A

A

RP 422

1)

RS 422/485

-

A

A

RP 485

1)

RS 422/485

X

A

A

RP CAN

CAN

X

A

A

RP PDP

Profibus DP

X

B

B

RP SUC

SUCOnet K

X

B

B

Interbus S

X

B

B

RP IBS

2)

RP DEV

DeviceNet

X

B

B

RP 2CA

3)

CAN1/CAN2

X

B

B or C

RP 2C8

3)

CAN1/CAN2

X

B

B or C

1)

full - duplex (4-wire)
additional plug Interbus Rem. IN (SUB D)
3)
additional plug COM 3 (B)
2)

2.6.2.1 additional In-/Outputs
module designation

inputs

outputs

connection via

design

slot

5

2

COM2

B

B

RP EAE

14

10

X200

C

C

RP 2C8

4

4

X120 B/C

B

B or C

RP EA5

4)

4)

no Fieldbus possibility (interface)

Caution!
The connections COM2 or COM3 B/C and X30 are implemented via SUB D09 socket.
It is to be guaranteed by the customer that an interchanging is not possible!
The solder ring jumpers JP2.8, 2.3, 2.7, 2.2 must be switched dependent on the option module.
See chapter 7.1 (factory-adjusted)

2.6.2.2 Additional CAN-BUS2 Interface
(Use in combination with other Fieldbus)
modul designation

interface

RP 2CA
RP 2C8

3)
3)

galvanic isolation

design

slot

CAN2

X

C

C

CAN2

X

C

C

additional plug COM 3 (B)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

36

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Digital Interfaces
2.6.2.3 Module Designs

Design A

Design B

Design C

2.6.2.4 Pin assignment for RS232
with option module RP 232
Pin
1
2
3
4
5
6
7
8
9

assignment as RS232
RXD
TXD
GND
-

2.6.2.5 Pin assignment for RS422/485
with option module RP 422, without galvanic isolation
with option module RP 485, with galvanic isolation
Pin
1
2
3
4
5
6
7
8
9

assignment as RS422/485
Data In
GND
Data In invertierted
Data Out invertierted
Data Out
-

Parallel wiring up to 16 devices

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

37

2

Connector Assignments and Functions
Digital Interfaces

2.6.2.6 Pin Assignment for CAN/DeviceNet
with option module RP CAN / RP DEV / RP 2CA / RP 2C8, with galvanic isolation
Pin

description

designation

1
2

CAN_L bus line
(dominant low)

CAN_L

3
4
5
6
7

Ground
Optional ground
CAN_H bus line
(dominant high)
-

GND
GND
CAN_H

8
9

-

2.6.2.7 Pin assignment for Profibus DP
with option module RP PDP, with galvanic isolation
description

designation

1

-

-

2

-

-

3

Line B

B

4

Request to send

RTS

5

Ground

GND

6

Potential +5V

+5V

7

-

-

8

Line A

A

9

-

-

Pin

2.6.2.8

Pin assignment for SUCOnet K
with option module RP SUC, with galvanic isolation
description

designation

1

-

-

2

-

-

3

Data line +

TA/RA

4

-

-

5

Signal ground

SGND

6

-

-

7

Data line -

TB/RB

8

-

-

9

-

-

Pin

________________________________________________________________________________________________________________________________________________________________________________________________________________________

38

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Digital Interfaces
2.6.2.9 Pin assignment for Interbus S
with option module RP IBS,

with galvanic isolation

Remote OUT (COM2)
Remote OUT (SUB D09 socket)
PIN
Com 2
1
2
3
4
5
6
7
8
9

description

designation

Data line OUT forward
(error voltage A)
Data line IN backward
(error voltage A)
Reference potential
VCCI
Data line OUT forward
(error voltage B)
Data line IN backward
(error voltage B)
Reporting input *

DO2
DI2
GND I
+5V
/DO2
/DI2
RBST

* to forward Interbus-S interface
Remote IN (COM3 B)
Remote IN (SUB D09 plug)
≅ additional plug
PIN
Remote
IN
1
2
3
4
5
6
7
8
9

description

designation

Data line IN forward
(error voltage A)
Data line OUT backward
(error voltage A)
Reference potential
Data line IN forward
(error voltage B)
Data line OUT backward
(error voltage B)
-

DO1
DI1
GND I
/DO1
/DI1
-

Attention: specific front panel is required !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

39

2

Connector Assignments and Functions
Digital Interfaces

2.6.2.10
Pin assignment for I/O interface
with option module RP EA5, with galvanic isolation
Digitale I/O Option
COM2 SUB D09 socket

PIN
designation
Com 2

comment

status

1

BIAS input 101

standard

input

2

BIAS input 102

standard

input

3

BIAS input 107

standard

input

4

BIAS input 108

standard

input

5

0VSPS

ground reference
0VSPS

6

BIAS input 106

standard

input

7

BIAS output 109

standard

output

8

BIAS output 110

standard

A

9

+24VSPS

ext. +24V feed-in

B

UB

Notice !!
The inputs with the internal number 107 and 108 must be connected to the pins with number 3 and 4.
The outputs with the internal number 109 and 110 must be connected to the pins with number 7 and 8

________________________________________________________________________________________________________________________________________________________________________________________________________________________

40

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Digital Interfaces
2.6.2.11 Pin assignment for I/O interface
with option module RP EAE, with galvanic isolation
Digitale I/O Option
X200 SUB D26 High Density socket

PIN
X200

designation

comment

1

Bias input 201

standard

input

2

Bias input 202

standard

input

3

Bias input 203

standard

input

4

Bias input 204

standard

input

5

Bias input 205

standard

input

6

Bias input 206

standard

input

7

Bias input 207

standard

input

8

Bias input 208

standard

input

9

Bias output 209

standard

output

10

Bias output 210

standard

output

11

Bias input 211

standard

input

12

Bias input 212

standard

input

13

Bias input 213

standard

input

14

Bias input 214

standard

input

15

Bias input 215

standard

input

16

Bias input 216

standard

input

17

Bias output 217

standard

output

18

Bias output 218

standard

output

19

Bias output 219

standard

output

20

Bias output 220

standard

output

21

Bias output 221

standard

output

22

Bias output 222

standard

output

23

Bias output 223

standard

output

24

Bias output 224

standard

output

25

+24 V SPS

Ext. +24 V feed-in

26

0 V SPS

Ground reference 0 V SPS

status

Ub
B

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

41

2

Connector Assignments and Functions
Digital Interfaces

2.6.2.12 Pin assignment for I/O interface
with option module RP 2C8, with galvanic isolation
Digitale I/O Option
X120B orr X120C Cage – Clamp terminal 10pole..
(min./max. cable cross-section: 0,08mm² / 1,5mm²)
PIN designation
X120

comment
Function 0

Function 1

status

1

Input 121

BIAS

Reset drive fault

Input

2

Input 122

BIAS

Limit switch +

Input

3

Input 123

BIAS

Limit switch -

Input

4

Input 124

BIAS

Reference switch

Input

5

Output 125

BIAS

Cam 1

Output

6

Output 126

BIAS

Cam 2

Output

7

Output 127

BIAS

Cam 3

Output

8

Output 128

BIAS

Cam 4

Output

9

+24 V SPS

Ext. +24 V feed-in

Ub

10

0 V SPS

Ground reference 0 V SPS

B

Signal statuses of the I/O are indicated in each case by a 2mm LED
at the front plate.

Connector COM3 B – see chapter 2.6.2.6

LED lighten I/O = high
LED off I/O = low

X120

________________________________________________________________________________________________________________________________________________________________________________________________________________________

42

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Digital Interfaces
2.6.2.12.1 DIL – switch position for module RP2CA and RP 2C8,
with galvanic separation
DIL – switch position CAN

Default = all off

20-------------------------------26

20---------22

baud rate

note number
0 - 127

222120
000
00I
0I0
0II
I00
I0I
II0
III

0
1
2
3
4
5
6
7

20 kBaud
50 kBaud
100 kBaud
125 kBaud
250 kBaud
500 kBaud
800 kBaud
1000 kBaud (1MBaud)

Example: node number 5; 1MBaud

DIL – switch position bus termination
COM2

COM3

Default

COM2/COM3

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

43

2

Connector Assignments and Functions

2.7

Option module RP SBT

2.7.1

Safe Stop
Connector assignment X290:
PIN
X290

designation

1

Input Active

2

Reference point
Input Active

comment
1)

status

OPTO

Input

OPTO

Input

3

Starting lockout
deactivated

Relais

Input

4

Reference point
Starting lockout

Relais

Input

5

Checkback contact

Free contact

Break contact

6

Checkback contact

Free contact

Break contact

Hinweis:
1)

With employment the option module RP SBT changes the function “AKTIV” from the connecting
plug X10.22 after X290.1! The input X10.22 can be used then as free programmable input
(BIAS).

Use of the function Safe Stop
The option RP_SBT of the drive controller 637fxx-x.S5 supports the safety function “Safe Stop”, protection
against unexpected starting, according to the requirements of the EN954-1 “Category 3” and EN1037.
The stop of the machine must be caused and guaranteed before by the external machine control.
This applies in particular to vertical axes without selflocking mechanics or counterweight.
If an error arises in the drive system during the active brake phase, the axis can coast down uncontrolled
or even accelerate actively.
In order to use the Starting lockout function intended, it is to be looped into the net contactor circle or
emergency stop circle with the obligation-led reporting contact X290.5/6. With not plausible functioning of
the Starting lockout relay, related to the operating mode of the machine, a galvanic separation of the drive
concerned from the net must take place. The Starting lockout and the associated mode may be used again
only after error correction.
Due to a danger analysis / view of risk (to be accomplished according to machine guideline 89/392/EWG
and/or EN 292; EN 954 and EN 1050) the machine manufacturer must project the safety circuit of its
machine types for the entire machine including all integrated components (also the electric drives).
Block diagram:

________________________________________________________________________________________________________________________________________________________________________________________________________________________

44

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Connector Assignments and Functions

2

Option module RP SBT
2.7.2

Brake control and PTC evaluation
Connector assignment X280
PIN
X280

designation

status

1

Supply for brake output and PTC evaluation

Input

2

Reference point for supply

Input

3

Reference point for Brake control

4

Brake control Active ok.

5

PTC

Input

6

PTC

Input

Output
Relais output

Use of the Brake control
The relay output X290.3 serves for the control of holding brakes. This output is functionally identical to the
output X10.23.
The output at X290.3 has the following advantages over X10.23:
The isolation relay contact
control electronics corresponds to the basis isolation. I.e. also brake
installations (which correspond to the basis isolation) without interface relays, while maintaining the
PELV isolation (double) of the drive controller are operated (see X10 connection example chapter 2.3.2)
The brake control possesses an active clamping of over voltages between the two brake connections.
Stronger dimensioning of the brake contact.

Use of the PTC evaluation
The PTC connection serves for the monitoring of the engine temperature. In its function mode it is
identical to the port X30.2/6. The following advantage exists over X30.2/6 :

control electronics corresponds to the basis isolation. I.e. also
The isolation evaluation circle
PTC thermistors (which correspond to the basis isolation) can be evaluated, without waiving the
safe separation to the control electronics.
Block diagram / Connector assignment
Circuit diagram

Further details see product manual 07-02-10-02-E-V..

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

45

3

Operating Mode

3
Operating modes
The preselection of the device functions are carried out by choosing the operating modes 0...5 according to
the following table, see chapter 3.1, (EASYRIDER® Windows - Software).
Each operating mode allows the assignment of different in- and output functions (F0..F6).
Operating
mode

Reference-source

Hints for selecting the operating

0
1
2

analog (X10.5/18)

switchable the operating modes 1 and 2 by input X10.24
speed control analog
torque controller analog

3

analog (X10.5/18) /
digital

simple applications with requirement of switching between
position and speed control position controller (input X10.24)
handling like operating mode 4

4

digital or analog in acc.
to parameter set

general position-controlled systems. Up to 10 positions can be
stored under identifier-numbers and activated like shown.

5

digital or analog in acc.
to programming or via
digital communication
(e.g. fieldbus)

simple to complex systems using instructions BIAS
(up to 1500 command blocks)
PLC - functions
for further information:
see chapter 13.1 and 13.2

________________________________________________________________________________________________________________________________________________________________________________________________________________________

46

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Operating Mode
3.1

3

Operating modes and pin functions
0
torque / speedcontrol

1
speed
control

operating modes
2
3
torque
position /
control
speed-control

input
X10.14

F0, F1

F0, F1

F0, F1

input
X10.15

F0, F1

F0, F1

input
X10.4

---

input
X10.25
input
X10.11

Available
pins
number

input
X10.24

4
position
control

5
position control
+ BIAS
functions

F0, F1, F2,
F3

F0, F1, F2,
F3,F6

F0, F1, F2,F6

F0, F1

F0, F1, F2,
F3

F0, F1, F2,
F3,F6

F0, F1, F2,F6

---

---

---

F2,F6

F0, F2, F3,F6

---

---

---

---

F2,F6

F0, F2, F3,F6

F1

F1

F1

F1

F1,F2,F6

F0, F1, F2, F3,F6

---

---

F1, F2,F6

F1, F2, F3,F6

F0
L = torqueH = speed
control

F0
L = torqueH = speed
control

input
X10.2

---

---

---

---

F0

F2, F3

output
X10.12

F0, F2, F5

F0, F2, F5

F0, F2, F5

F0, F1,F3, F5

F0, F1,F3,
F5

F0, F1, F2, F3,
F4, F5

output
X10.13

F0, F2, F5

F0, F2, F5

F0, F2, F5

F0, F1,F3, F5

F0, F1,F3,
F5

F0, F1, F2, F3,
F4, F5

output
X10.20

F0, F2, F5

F0, F2, F5

F0, F2, F5

F0, F1,F3, F5

F0, F1,F3,
F5

F0, F1, F2, F3,
F4, F5

output
X10.23

F0, F2, F5

F0, F2, F5

F0, F2, F5

F0, F1,F3, F5

F0, F1,F3,
F5

F0, F1, F2, F3,
F4, F5

The assignment of the functions F0..F5 is listed in the following table

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

47

3

Operating Mode

3.2

Configurable pin-functions (depending on the operating mode)
Input functions (depending on the operating modes)

input
Nr.

function
F0

input
X10.14
input
X10.15

function
F1

function
F3

function
F4

function
F5

⌧

3)
1) move manually
+
limit switch + set selection
data 20

⌧

⌧

⌧

3)
1) move manually
limit switch - set selection
data 2a

⌧

⌧

input
X10.4

latch input 1

input
X10.25

latch input 2

input
X10.11

start (slope 0->1) for BIAS move commands

input
X10.24

operating mode
selection
(0) – 1or 2
(3) – 1or 4

extended
latch

1)
set selection
data 2b
1)
set selection
data 2c

⌧
3)
regulator
trouble reset
3)
reference
sensor

input
X10.2

start (slope 0-->1)
with position set
selection in
position control (4)

⌧

output
X10.12

position
reached

reference
output

output
X10.13

temperature
monitoring

reference
output

output
X10.20

warning

reference
output

output
X10.23

active ok
(motor brake)

⌧

function
F2

reference
output

1)
set selection
data 2d
1)
set selection
data 2max

strobe
(slope 0-->1)
for BIAS-set
selection

⌧
⌧
⌧
⌧

⌧
⌧
⌧

⌧
⌧
⌧

function
F62)
CAN
Node no.
20
CAN
Node no.
2a

⌧

CAN
Node no.
2b

⌧

CAN
Node no.
2c

⌧

CAN
Node no.
2d

⌧

⌧

⌧

CAN
Node no.
2max

⌧

⌧

⌧

⌧

tracking
window
exceded
tracking
window
exceded
tracking
window
exceded
tracking
window
exceded

synchronformat
trigger

non
drive trouble

-

start offset
trigger

non
regulator
trouble

⌧

non
drive trouble

-

⌧

non
drive trouble

-

-

BIAS-function, free programmable.(in operating mode 5) resp. no function in operating mode 0 at 4.

fast input for optimal timing
1) With every row (from the top to the bottom) in which the function F2 is assigned to an input, the binary
value (2n) increases by 1. (see example)
Operating mode 4: only permissible set number 0 - 9 !
2) only possible with module RP-CAN.
3) Is the Option RP 2C8 (chapter. 2.6.2.12) insertion, are the contact function as the same definition on X10plug invalid (the inputs can freely programmable and use in BIAS program)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

48

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Operating Mode
3.3

3

Function diagrams from inputs and outputs
Pro te ctio n mo de s witc hing off

Pro te ctio n mo de limiting
acc.
with EAS YR ID ER co nfig . me nue
in acc. with EA SYR ID ER config.- menue

Fa ult s ig nal /
prote ctio n func tio n
I 2t

re gulator prote ction

outp ut Warning(F0) X 10.20
/8/

outp ut Ready X 10.8

/3/

Warnin g time ap p rox. 3 sec.
/3/

ma x. cu rrent

I-LIM IT

Warnin g disp lay

rated curr ent of re gulator

fault signa l d isp lay

m otor prote ction
I 2t
outp ut Warning(F0) X 10.20
outp ut Ready X 10.8

/8/

/4/

Warnin g ti me ap p rox. 3 sec.
/4/

Warnin g disp lay

ma x. cu rrent

I-LIM IT

rated curr ent of motor

fault signa l d isp lay

N TC -ou tput stage prote cti on

95 °C

outp ut Warning(F 0) X 10.20
outp ut Ready X 10.8

Warnin g ti me ap p rox. 6 sec.

/8/

/5/

/5/

Warnin g disp lay

I-LIM IT

90 °C

100 °C

fault signa l d isp lay

Tem p.
assume motor temp erature
curve

Tem p.

V2
V1

R_NTC1
R_PTC
t1

N TC -m otor prote ction

V2
V1

R_NTC2

R_NT C1
R_PT C

t

t2

R_NTC2

t1

t2

t

decre ase as of R_N T C1

sw itch off w ith R_ N T C2

outp ut T emp .(F0) X 10.13
outp ut Ready X 10.8

/h/

/h/

Warnin g disp lay

/9/

/9/
current lim itin g

I-LIM IT

fault signa l d isp lay

PTC -m otor prote ction
sw itch off w ith R_ PT C after w arning t ime
outp ut T emp .(F0) X 10.13
outp ut Ready X 10.8
Warnin g disp lay

no lim itin g function w ith PT C
Warnin g time ap p rox. 6 sec.

/h/
/9/

fault signa l d isp lay

Function Passive -D e lay (re com m ande d by use of m otor brake )
inp ut A CT IVE X 10.22
setp oint internally to z ero

Nsoll

N setp oint

outp ut stage A ctive
outp ut AK TIVE -O K (F0) X 10.23 (holdin g br ake )

reaction time for br ake

Hint: With the assembly of the option module SBT you kindly note the extended functions of the signals
(see documentation 07-02-10-02-E..)
________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

49

4

Mechanische Installation

4

Mechanical Installation

4.1

Mounting

SSD Drives digital servo drives may be installed only in a vertical position to guarantee the best air
circulation for the cooling ribs of the heat sink. Vertical installation above other drive racks or above other
heat producing devices can lead to overheating. In addition the drives are to be operated exclusively in
SSD Drives racks or the compact enclosure respectively.

4.2

Control cabinet - mounting

Installation should be carried out only in a control cabinet in which the inside must be free from dust,
corrosive fumes, gases and all liquids.
Make absolutely sure that the condensing of evaporating liquids including atmospheric moisture is
avoided. Should the digital servo drive be installed in a place where condensation is likely, a suitable
anticondensation heater must be installed. The heater must be SWITCHED OFF during normal operation.
Automatic switch off is recommended
SSD Drives-digital servo drives should not be installed in are as which have been classified as
dangerous, if they have not been installed in an approved enclosure an accordance with regulations and
checked.
Make sure, there is enough cooling and space ! (see sketch)
only horizontal !
on the side
no distance is required

General rule:
It is better to place heat-producing devices low in an enclosure to support internal convection and to
spread the heat. If placing such devices up high is unavoidable, enlarging the upper dimensions at the
expense of height or installing fans should be considered.

4.3

Cooling

The digital servo drives are protected against damages caused by overheating.
There is a thermal sensor installed on the heat sink. When the temperature rises to >95°C,
the drive is automatically switched off. This setting cannot be changed.
Make sure a cabinet of proper size is selected for adequate air circulation
If the device becomes operated in a not ventilated device, the case volume of the specified control
cabinet must be calculated in accordance with the following table !

Units

Volume of cabinet

637f/0D6R02...D6R10
637f/0D6R16...D6R30

0,12 m³
0,25 m³

For more exact information, please, address to the control-cabinet manufacture

________________________________________________________________________________________________________________________________________________________________________________________________________________________

50

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Electrical Installation
5

Electrical Installation

5.1

Safety

5

The voltages carried by power supply cables, motor cables, connectors, and certain parts of the drive can
cause serious electric shocks and even death

5.2

The danger of electric shocks

Caution !

Risk of electrical shock, wait 3 minutes after switching off, for discharging the capacitors.
Disconnect SSD Drives plug-in units from mains before working on them. A period of three minutes must
pass after switching off so that the internal capacitors can discharge completely. Until the discharge time is
over, there can be dangerous voltages in the module !
Persons, which monitoring or carrying out electrical installation and maintenance must be adequately
qualified and schooled in these activities.

5.3

Danger areas

The use of variable speed drives of all kinds can invalidate the certification for dangerous areas (apparatus
group and/or temperature class) of explosion-protected motors. Inspection and certification for the
complete installation of servo motors and electronic components must be obtained.

5.4

Grounding, safety grounding

The grounding impedance must meet the requirements of local industrial safety regulations and should be
inspected and checked at appropriate and regular intervals

5.4.1

Ground connections

It is recommended to attach a ground bus of high conductivity copper as near as possible to the servo-rack
or regulator modules in order to minimize the length of the cable connections.
The recommended dimensions are:

Thickness: d = 5 to 6 mm
Length
Width
(m)
(mm)
< 0,5
20
0,5 < 1,0
40
1,0 < 1,5
50

d
b

grounding bus-bar

l
Ways of raised discharge currents > DC 10mA resp. > AC 3,5mA the PE-Bolt of the drive has to be
connected to PE using copper-cable minimum 10mm² !

5.5

Short-circuit capability and discharge currents

Due to the working-principle of servo drives there may discharge currents to
PE exceeding DC 10mA resp. AC 3,5mA.
Suitable for use on a circuit capable of delivery not more than 5000 RMS symmetrical
amperes 505V maximum. (Note according to UL508C)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

51

5
5.6

Electrical Installation
Fuses, contactors, filters

Compact units

Fuses, Contactors
RCD-switch
mains input currents
mains protection
protector-switch
mains fuse
Line filters
general
industrial env.
max. motor cable 50m
(EN55011 A)
residential env.
max. motor cable 20m
(EN55011 B)

industrial env.
max. motor cable 50m
(EN55011 A)
residential env.
max motor cable 20m
(EN55011 B)
industrial env.
max. motor cable 20m
(EN55011 A)
residential env.
max motor cable 20m
(EN55011 B)

637f/ KD6R 02 KD6R 04 KD6R 06
.S5
.S5
.S5
-3
-7
-3
-7
-3
-7

KD6R 30
.S5
-7

4)
not recommended. Required setpoint: 300 mA, no protection against life danger
[A]
3,5
5
7,5
12
19
26
30
1) Type
T10A
T10A
T10A
T20A
T25A
(T32A) 35A (T32A) 35A
2) Type PKZM0-16 PKZM0-16 PKZM0-16 PKZM0-16 PKZM0-25 PKZ2/ZM32 PKZ2/ZM32
2) Type DIL 00M
DIL 00M
DIL 00M
DIL 00M
DIL 0M
DIL 0M
DIL 0M
4)
only for use in earth referenced supplies(TN). Current drain to PE !
single-phase
Type
LNF E 1*230/012
not possible !
up to AC 230V !!
+
ferrite core
Type
LNF E 1*230/012
not possible !
up to AC 230V !!
+
ferrite core
3-phasig
LNF B 3*480/033
LNF B 3*480/018
Type
LNF B 3*480/008
+
+
+
ferrite core FR 6
ferrite core FR 6
ferrite core FR 3
LNF B 3*480/033
LNF B 3*480/018
Type
LNF B 3*480/008
+
+
+
ferrite core FR 3
ferrite core FR 3
ferrite core FR 3
3-phasen, max. 3 Units, supplied by a common filter
Type
LNF B 3*480/018; LNF B *480/033 + ferrite core FR
other types upon request
(according to ref.measurements with 3 units, supplied by common line)
Type
LNF B 3*480/018; LNF B 3*480/033 + ferrite core FR
3)
other types upon request
(according to ref.measurements with 3 units, supplied by common line)

Plug-in modules

Fuses, contactors,
filters

KD6R 10 KD6R 16 KD6R 22
.S5
.S5
.S5
-3
-7
-7
-7

637f / D6R 02 D6R 04 D6R 06 D6R 10 D6R 16
.S5
.S5
.S5
.S5
.S5
-3 -7 -3 -7 -3 -7 -3 -7 -3 -7

D6R 22
.S5
-3
-7

D6R 30
.S5
-3
-7

4)
1)

general

Orientation: Table for compact units and the addition of rated currents of used
units on the DC-Bus. Depending on the application, energy sharing effects by
DC-link may reduce the required supply current considerable.

fuses

Rule of the thumb: single-phase operation: 2...3 times of added rated currents
Rule of the thumb: 3-phase operation: 1,5...2 times of added rated currents

peak making currents

Depending on power-supply unit, limiting equipment is requiered (delay contactor)

filters

only for use in earth referenced supplies(TN). Current drain to PE !

filter types

Orientation: Table of compact units. Further types: see separate manual

1) recommended for UL-requirements: Bussmann Type FRS-R, 600V, use only UL-approved fuse-holders !
2) recommended, Klöckner Moeller for instance
3) Measurement of conducted emissions only
4) for applications with continuous load: see notes in chapter 5.7

________________________________________________________________________________________________________________________________________________________________________________________________________________________

52

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Electrical Installation
5.7

5

Correction of supply current

Attention in case of continous load:
Due to the capacitive input impedance of
DC-Bus, the input current is deformated.
This guides to RMS -values higher than the sinus-based calculated values. Fuses,
contactors and line filters have to be selected in respect to this effect.
In typical servo application with Stop/Go-operation (S3-Operation), the
rating to nominal data will be sufficient.
In other cases, the value has to be corrected using the following diagram.

Example:
Drive type 637f/KD6R16.S5-7 is supplied by AC 230V 3-ph.
Output-power: Pout = 200V x 16A x 1,73 = 5,54 kW
This output-power must be generated by:
calculated supply-current Iac sinus = 5,54kW / (230V x 1,73) = 13,9 A
Correction-Factor from diagram: 1,6
RMS. Supply-Current Ieff = Iac sinus x 1,6 = 22,3 A
Result:
All supply-equipment has to be selected in respect to the enhanced current.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

53

5

Electrical Installation

5.8

Brake resistor

5.8.1

Selection of the brake resistor

The energy of a moving system flows back to the Drive. The DC-Bus capacitors are able to take a small
value. The rest has to be converted to heat by a resistor.
Switching of this brake resistor depends on the DC-Bus voltage.
The load of the resistor is simulated and supervised electronically
(EASYRIDER® Windows - Software). Peak power (Pmax) and continuous power (Pd) ratings have to be
sufficient to meet the requirements of the application.

RPM
n1

I [A]
Ib

Movement
Definition of Data

tb1

T
Braking-Current

t [sec]
t [sec]

Speed at Brake-Start
Braking Time
Cycle-Time
Total Inertia
Braking-Current
Motor-Resistance
Cable-Resistance

Values for Example
n1 = 3000 RPM
tb1 = 0,1 sec.
T = 2,0 sec.
J = 0,0005 kgm²
Ib = 3,2 A
Rph = 3,6 Ohm
RL = 0,3 Ohm

Calculation
Step 1

example

Calculation of brake-power
(Approximation. Capacitor-load, friction-and drivelosses neglected)
Power of motion:
Pkin = 0,0055 * J * n1² / tb1 [W]

Pkin = 0,0055 * 0,0005 * 3000²/0,1
Pkin = 247 W

Motor-losses:
Pvmot = Ib² * (Ri + RL) [W]

Pvmot = 3,2² * (3,6 + 0,3)
Pvmot = 40 W

Cont. Power:
Pd = 0,9 * (Pkin-Pvmot) * tb1 / T
[W]

Pd = 0,9 * (247 - 40) * 0,1 / 2
Pd = 9,3 W

Peak-Power:
Pmax = (1,8 * Pkin) - Pvmot [W]

Pmax = (1,8 * 247) - 40
Pmax = 405 W

used units:
J
total inertia [kgm²]
n1 speed at Brake-Start [RPM]
tb1 braking time [Sec]
T
cykle time [Sec]
Ib brake-current [A]
Rph resistance of motor (between terminals) [Ω]
RL line resistance of motor cable [Ω]

________________________________________________________________________________________________________________________________________________________________________________________________________________________

54

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Electrical Installation

5

Brake resistor
selection of the brake resistor

Step 2

Example-Drive type

Internal / external Brake-resistor required ?
see data in chapter 1.3.3 / 1.3.4

637f/K D6R04-7

In case of unsufficient capability or not included
internal Brake-Resistor, a type may be selected from
the following list
External and internal Brake-Resistors will be switched
in parallel. The internal and external performance-Data
may be added in this case.

5.8.2

acc. to data in 1.3.3:
internal resistor:
Cont. Power Pd = 30W
Peak Power Pmax = 1700W
Required:
Pd = 9,3W Pmax = 405W
Result: The internal capability is sufficient

Configuration of the brake resistor

Possible ballast circuit configurations at digital devices
a) Compact design
The plug-in modules of servo-control series 635/637/637+/637f are provided with an on board ballast
electronics. It is intended for application as compact unit KDER resp. KD6R.
These compact units contain the necessary ballast resistor incl. fuse for the ballast circuit.
Except KD6R 16..30-7 (external resistor only).
b)

Rack design
While the plug-in modules are used in a rack, the NEB power supply module takes dissipation
of the braking energy (adjustment of ballast monitoring: please see NEB manual).
In this case the ballast electronics of the plug-in module will be deactivated with the
configuration parameter "Ballast activate = N". All further ballast parameters are no longer
relevant then.

r.g. a) Adjustment of ballast circuit for compact units:
1. Ballast electronics activated:
In this case the ballast electronics of the plug-in module will be activated. "Ballast activate = J".
2. Operating point:
The operating point has to be adjusted dependent on the voltage variant.

"Ucc Ballast on = 375 V"

for 230 V AC supply

"Ucc Ballast on = 720 V"
for 400..460 V AC supply
3. Resistance value:
As resistance value, the parallel resistance from internal and external resistance has to be adjusted.
4. Rated power:
As ballast power (braking energy), the sum total of internal and external resistor power
has to be adjusted.
Precondition for correct monitoring of shunted ballast resistors is the nearly same ratio of P - cont.
power to P - pulse power. This is guarantied with the SSD Drives standard combinations.
..KD6R 16..30-7 units do not contain an internal ballast resistor.
At these versions the values of the external resistor can be feed directly.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

55

5

Electrical Installation
Brake resistor
selection of the brake resistor

Example:

EASYRIDER

Evaluation resistance value in use of internal and external resistances.
Internal “Ballast resistances = 300 Ohm“ for ..KD6R10..-7
External “Ballast resistances = 100 Ohm“ for ..KD6R10..-7

formula :

1
1
1
=
+
Rtotal. R int . Rext.
1
1
1
=
+
⇒ Rtotal. = 75Ω
Rtotal. 300Ω 100Ω

Set up resistance value = 75 Ohm
Evaluation Ballst power in use of internal and external Ballast power.
Internal “Ballast power = 30 Watt“
External “Ballast power = 100 Watt“

for ..KD6R10..-7
for ..KD6R10..-7

formula : Ptotal. = Pint. + Pext.
Ptotal. = 30W + 100W ⇒ Pges. = 130W
Set up rated power = 130 Watt

Caution !
Placing of external brake resistors
Brake-resistor are dissipating heat !
Make sure, that there will be no fire-danger in case of operating the resistor
in nominal- or fail-conditions

________________________________________________________________________________________________________________________________________________________________________________________________________________________

56

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Wiring Instructions
6

Wiring instructions

6.1

General Information

6

Digital servo drives are designed for operation in metallic grounded enclosures.
For perfect operation as well as for observance of all regulations the front board must be connected
with the enclosure electrically and fixed.

6.2

Control cabling

Recommended cross section 0,25 mm².The control signal lines must be laid seperate from the power
signal lines.(see chapter 6.7.1)
The resolver cable must contain three shielded pairs and must be shielded as a whole. The shielding
should be connected to the ground spread out on the regulator side. We recommend using SSD Drives
resolver cable KIR. Cable for transmitting data are always to be laid shielded !

6.3

Power cabling

Recommended section according to rated current. Use only 75° Cu-cables.

6.4

Installation of the rack

When the rack is secured not in a hinged bay but on a mounting plate, it is recommended to do the wiring
of the connections for the power connector X50 on the rear of the rack before installing. With hinged-bay
installation, the customer must ensure that the parts sensitive to voltage such as the Ucc bus, mains
supply lines, etc., are protected against electric shock.

6.5

Analog setpoint

The setpoint input is a differential input. Therefore the poling can be done depending on the requirements.
Important: the setpoint voltage must be galvanically connected to the reference potential of the control
connections (plug X10). It is possible to connect one pole directly to GND.

6.6

Safety rules

Caution !
Plug / unplug all modules only when
Ucc (DC-BUS) is off, that is, the green LED on the power supply module is off and the discharge
time > 3 minutes has elapsed.
The user must ensure protection against accidental touching.

6.7

Electromagnetic compatibility (EMC)

Confirmity in accordance with the EEC Directive 89/336/EEC has been evaluated using a referencesystem, consisting of a compact type drive and a line-filter on mounting-plate,
connected to an AC-syncronous motor.
Mainly responsible for EMC-emissions is the motor cable. So this has to be installed exeptional carefully.
The layout of grounding is very important. Grounding has to be low-impedant for high frequences. That
means, all ground-connecting parts have to use area.
The measurements made are valid under the use of SSD Drives - cables, suppression aids and line filters
and by application of the following wiring instructions:

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

57

6

Wiring Instructions
Electromagnetic compatibility (EMC)

6.7.1
A

B

C

Hints for mounting
All components are mounted inside of
a steel control cubicle on a mounting plate
(thickness min. 3mm).
Recommended: Galvanizing

3mm

The connection between drive housing filterhousing and mountig-plate must be blank and
not reduced by varnish. All screws must be well
fixed !
Use only SSD Drives-filters and cables for motor
and resolver

D

Place all wires and cables as close as possible
to any grounded metal parts

E

Separate power- and control cables. Minimum
distance: 0,3m
crosspoints: 90°

F

Avoid cable-loops. Especially the line between
line-filter and drive has to be as close and short
as possible (drilled)

G

Maintain screen as close as possible to the
cable-end (max distance 8 cm)

H

Connect screen-connections according to
general view of connetions, see chapter 2.1.
Ground screens on both sides, shortest way.
For long cables: Connect additional screen-area
along the way
Connect screens area-contacted to good
grounded points

0,3 m

90°

8 cm max

I

K

Connect unused wires in cables to ground

L

Install control cables directly close to grounded
metal-parts or screend when leaving the controlcubicle
Take care for good grounding of controltransformer (DC 24V). Use transformer with
metal-socket and take care for conductive
contact to mounting-plate
Take care for good general grounding of the
complete system. Interconnect several
mounting-plates with copper-rails or
copperband. Take care for ground connection
between control-cubicle and machine !

M

N

________________________________________________________________________________________________________________________________________________________________________________________________________________________

58

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Wiring Instructions

6

Electromagnetic compatibility (EMC)
6.7.2

Example for mounting

6.7.3

Achieveable specifications and conditions

Emissions:
transmitted by
cable or by air

Interference
immunity:
(≅ radiation)
transmitted by
cable or by air

Area
Industrial

Class
A

conditions
additional conditions
Motor-cable
Standard
length
Area Class
Standard
EN50081-2/
see
LNF S/E
closed
toroidal
EN55011Klasse A chapter 5.6
LNF B
cabinet with
ferrite
cores
≥ 15 dB
see
attenuation

Residential

B

EN50081-1/
EN55011 Klasse
B

Industrial

A

EN50082-2

Residential

B

see
chapter 5.6

LNF S/E
LNF B

chapter
5.6

-

-

-

-

-

-

-

-

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

59

7

Setting and Programming

7

Setting and programming

7.1

Jumper
All jumpers are set to a standard position in production !
Layout of the Jumpers see: Chapter 1.2.3
JP100,
bridged pad...
2 and 3
(standard)
1 and 3
JP101,
bridged pad...
2 and 3
(standard)
1 and 3

JP102,
bridged pad...
2 and 3
(standard)
1 and 3

JP1, JP2
bridged pad...
2 and 3
(standard)
1 and 3
JP3, JP4
bridged pad...
2 and 3
(standard)
1 and 3
JP2.8, JP2.3
JP2.7, JP2.2
open
close

READY contact with reference to
common output supply voltage on
X10.21
READY contact can be wired freely

Analog input X10.19 without internal
Pull-up.
Analog input X10.19 with internal Pullup to +12 V (FRR compatible)

X10.23 = active ok. output
X10.23 = GND internal
(FRR compatible)
adjust identically !
X10.15 = high-active
X10.15 = low-active
adjust identically !
X10.14 = high-active
X10.14 = low-active

Default, RP CAN, RP DEV, RP PDP
RP 2CA, RP 2C8
RP 232, RP 422, RP 485,
RP IBS, RP EA5, RP SUC

JP209 2-3
JP209 1-3
close
Default RP SBT
Further connecting configuration see:
Product Manualo 07-02-10-02-E-Vxxxx RP_SBT

7.2

Digital communication
see: Chapter 13

________________________________________________________________________________________________________________________________________________________________________________________________________________________

60

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Commissioning
8

8

Commissioning

Caution !

Wiring errors or incompatible operation may cause unpredictable motions.
Avoid danger for man and machine !

8.1

Preparation
For PC-link use the SSD Drives communication software
EASYRIDER® Windows - Software. For the start,

we suggest exercises in simulation mode to get familiar with EASYRIDER.This chapter
presumes the knowledge how to handle EASYRIDER. Suggestions: Use test equipment to
train yourself. EASYRIDER® Windows - Software contains interactive HELP - functions.
For security-reasons the access to several functions is blocked by password. Commissioning
has to be executed by trained stuff only.
Users may have their application-adapted commissioning methods when familiar with
the product, on their own responsibility.
The system must be in accordance with all valid safety specifications. The function of all
safety equipment (limit-switches for example) have to be checked.
To activate the power-stage of the drive, the "ACTIVE"-signal (X10.22 against X10.9)
has to be exited.
Hint: With the assembly of the option module SBT you kindly note the extended functions of the
signals
(see documentation 07-02-10-02-E..)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

61

8

Commissioning

8.2

Commissioning in steps

Step

Action

Remark

1

Before switching on
Check the wiring, especially:
Filter polarity, supply
Motor wiring, motor polarity
Resvolver wiring,
polarity (or other feedback systems)

2

With critical mechanical part: remove motor shaft from
application

3

Connect PC by RS232 link to the drive service port COM1
and start EASYRIDER ®

4

Set up state
NOT ACTIVE

avoid danger

7-segmentdispay

635/ 637/ 637+/ 637f 1)

631

X10.22 against X10.9

X10.7 against X10.4

Power on
5

7-segmentdispay

Switch on control voltage
635/ 637/ 637+/ 637f

631

Us = 24V DC

Us = 230V AC

EASYRIDER ® communicates (see diagnosis F9)
6

Are parameters already evaluated?
Yes: load parameter-file
xxx.WDD.
Store parameters in the
drive. If existent: load BIASfile xxx.WBD and store in
drive.
Proceed with 10 or 15
(experts)

7

No: continue with 7

reduced torque

Menu Commissioning:
®

Select the used motor from the EASYRIDER - Library
Adjust max. current to nominal motor current or smaller

1)

8

When leaving that menu:
Tuning-parameters for current loop will be calculated and
offered to the user.
Normally, these values give dynamic servo motion.

9

Store data power-fail-save in the drive

10

Menu: Tuning speed loop

Confirm acceptance of offered
parameters

Hint: With the assembly of the option module SBT you kindly note the extended functions of the
signals (see documentation 07-02-10-02-E..)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

62

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Commissioning

8

Commissioning in steps
Step
11

Action

Remark

“ACTIVE” switched
7-segmentdispay

12

Adjust test generator as required.
Activate test generator with “START F8”.
Activate graph to display motor current or speed.
Can be optimize manually
(P- and I- gain)

13

Is the result ok?
Yes: continue with 14

14

No: continue with U1

Preparation to the position controller
The commissioning of the position controller is first
recommended without linked mechanics. In the case of
secure function, the mechanics can then be linked up.

15

Power OFF.
Connect motor-shaft to application
Move application to a free area between mechanical
limits.
Power ON.
Menu: Tuning position loop

16

Adjust test generator. Select Pos. 1 and Pos. 2 to
uncritical value.
Select slow speed and low acceleration first, rise up later

17

“ACTIVE” – switched. Every activation of “START F8”
excites a motion form Pos. 1 to Pos 2 and with next
activation, form Pos. 2 to Pos. 1

18

Observe the behaviour of application and graph.
Optimize tuning-parameters (P-, I- and V gain)

19

Is the result ok?
Yes: continue with 20

20

mind: reaction-time- to
Emergency stop

No: continue with 9

Basic power-up is done now.
Further functions (Interfaces, fieldbus functions,
synchronizing and so on may be done adapted to
selected equipments

21

Select the menu “File” store parameters” and store the
data in the regulator, protect against lost, with F7-key

data save

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

63

8

Commissioning
Commissioning in steps

Step
U1.1

Action

Remark

Menu: Tuning Speed Loop
Stabile parameters are calculate bases on the
system data; and can be called up with “Default
value”.
Sometimes it is recommended to make further
manual tuning.
Rated value can be soured either digital by the
internal generator or analogue by
635/ 637/ 637+/ 637f
+/- 10V at X10.5/18

U1.2

631
+/- 10V at X10.1/2

P- gain too high or I-time constant too
small
Motor noise

ATTENTION!
Too hard tuning will cause current-ripple and high
power dissipation.
Too weak adjustment cause slow loops reactions
that may cause problems for the tuning of position
loops.

P- gain too small or I-time constant too
high
U1.3
U2.1

It the result ok?
Yes: continue with 9
Menu: Tuning Current Loop
Stable parameters are calculated bases on the
system data and can be called up with “default value”
Manual tuning may be useful.
Rated value can be soured either digital by the
internal generator or analogue by
635/ 637/ 637+/ 637f
+/- 10V at X10.5/18

No: continue with U2.1

631
+/- 10V at X10.1/2

ATTENTION!
Tuning of current loops should be only done after
consultation of SSD Drives experts.
continue with 9

________________________________________________________________________________________________________________________________________________________________________________________________________________________

64

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Diagnosis and Trouble-Shooting
9

Diagnose und Fehlersuche

9.1

7-segment display

9

Many sources of faults can be narrowed down with the diagnosis display.
display

Output

explanation

servo drive
2)

comment

ready

warning

no display

off

off

off

off

off

off

off

off

deactivated via input.

on

off

deactivated via serial command.

off

off

Active input is activated with switching on
24 V control voltage

off

off

631

635/637

637+

637f

X10.7

X10.22

X10.22

X10.22

any control voltage? external fuses ok?
system ready for operate
drive ready, not active
drive ready for operate!
DC link voltage within the limits,
power stage active, fault-free
internal STOP with serial deactivating
activate drive via serial interface
regulator of serial interface (bus interface)
deactivated !
only if bus interface is integrated
deactivated with delay time for the brake

switch enable X10.xx switch on 0 V and
after that 24 V
Under voltage of control voltage

off

off

off

off

off

off

1)

1)

Power supply switched on? Power supply o.k ?
internal fuse o.k.? control voltage < 17 V
Under voltage in DC-bus < Ua low threshold
check power supply (power supply unit, wiring,
fuse), check under voltage parameter
feedback system error (e.g. resolver)
wiring to encoder system ok?
encoder system supply ok?
I²t- overload of the drive
does the control loop oscillate?
P-amplification too high mechanics stiff?
requirements too high? is warning /8/ evaluated?
1)

Reaction to these errors chapter: Function diagrams from inputs and outputs
With configuration corresponding chapter : Operating modes and pin functions
3)
Only warning respect. status indicator
The error signals are shown as long as there is control voltage (Us), also when the power (DC-Bus)
is switched off for safety reasons.
2)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

65

9

Diagnosis and Trouble-Shooting
7-segment display
display

Output

explanation
ready

comment
overload of the motor I²t

servo drive
2)

warning

1)

1)

1)

1)

1)

1)

off

off

WARNING!
Overload of the regulator I²t or motor I²t or temp.output stage too high. If no reaction within approx.
3sec.it switches off with signals /3/, /4/ or /5/.
Signal /8/ clears when there is no more danger or it
is switched off
mechanics stiff? defective bearings; cold grease?
reduce requirements and creep to next possible
STOP

on

1)

over temperature motor(NTC/PTC)

off

631

635/637

637+

637f

does the control loop oscillate?
P-amplification too high mechanics stiff?
requirements too high? is warning /8/ evaluated?
over temperature of the output stage (> 95°C)
adequate cooling of the regulator?
ambient temperature too high?
over voltage on DC bus
ballast module ok? adequate ballast module?
chassis shorting and short circuit due to hardware
motor cabling ok? digital-loops setup ok?
short circuit to chassis in the motor? braking
resistor: ohm- value too low? try to start fresh! send
in for repair

check overload of the motor / cooling etc.
motor temperature too high

on

1)

on

1)

check overload of the motor / cooling etc.
ballast active
Brake energy is removed
warning I²t ballast too high
ballast resistance usage >90%
switch off ballast
ballast resistance overloaded
1)

Reaction to these errors chapter: Function diagrams from inputs and outputs
With configuration corresponding chapter : Operating modes and pin functions
3)
Only warning respect. status indicator
The error signals are shown as long as there is control voltage (Us), also when the power (DC-Bus)
is switched off for safety reasons.
2)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

66

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Diagnosis and Trouble-Shooting

9

7-segment display
display

Output

explanation
ready

comment
X 300 – Module not inserted
or wrong inserted or defect

off

servo drive
2)

warning

631

635/637

637+

637f

X10.8

X10.14

X10.14

X10.14

X10.9

X10.15

X10.15

X10.15

X10.8
X10.9

X10.14
X10.15

X10.14
X10.15

X10.14
X10.15

off

X 300 testing
X 300 – setting wrong
X 30 / X40 Counter-Configuration test in
the EASYRIDER® Windows – Software
3)

tracking window exceeded
only in operation mode position control, will be
deleted with the next run-command
tracking error with switch off
only in operation mode "position control"

3)

limit switch +
limit switch + X10.xx on 0 Volt,
from Firmware 6.16

3)

limit switch limit switch - X10.xx on 0 Volt,
from Firmware 6.16

3)

limit switch + / limit switch both limit switch X10.xx on 0 Volt,
from Firmware 6.16
memory-checksum-error

off

off

try new start, store the value again
DC Bus Unterspannung < 100 V
1: internal software error, Watchdog
2: blinking: BIAS software error
1: Firmware version check
2: Bias program error fix
1)

Reaction to these errors chapter: Function diagrams from inputs and outputs
With configuration corresponding chapter : Operating modes and pin functions
3)
Only warning respect. status indicator
The error signals are shown as long as there is control voltage (Us), also when the power (DC-Bus)
is switched off for safety reasons.
2)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

67

9

Diagnosis and Trouble-Shooting
7-segment display
display

Output

explanation
ready

comment

servo drive
2)

warning

631

635/637

637+

637f

starting lockout RP SBT
terminal X290. 3/4 check
Max. speed overload
check speed limits resp. setpoint speed
CAN - Open 402 Sync Message error in
Interpolated positioning mode

6.19c

8.19d

-

1)

Reaction to these errors chapter: Function diagrams from inputs and outputs
With configuration corresponding chapter : Operating modes and pin functions
3)
Only warning respect. status indicator
The error signals are shown as long as there is control voltage (Us), also when the power (DC-Bus)
is switched off for safety reasons.
2)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

68

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Diagnosis and Trouble-Shooting
9.2

9

Reset of a regulator trouble

A general precondition for correct execution of the Reset is the elimination of the error cause.

The error signals
at
blinking
(BIAS)

of the drive can be reset via:
1. Control voltage OFF/ON,
2. the serial command “Drive Reset“ 0x02
The host login must be occurred.
The drive must be deactivated via the serial command “deactivate Drive“ 0x00.
3. the fieldbus-command “ Drive Reset“ 0x16 (22 decimal)
The host login must be occurred via the BUS command 0x01.The drive must be deactivated
via the BUS command “deactivate Drive“ 0x14.
The fieldbus command “Drive Reset“ with constant repetition of the fieldbus command 0x16 will be
works-off only once.
For further processing, it is necessary, meanwhile to send another control word
(e.g. 0 status order).
4. a 0 – 1 flank on input X10.11
Precondition:
- The input X10.11 is with function 1“Reset drive fault“ configured
(EASYRIDER® Windows – Software)
- There is no host login.
1)
- The input Active,(X10.22) is inactive (0V)
- The signal must be present min. 250 ms
Notice !!
After remove of the tracking error deactivation
the warning message
(tracking error) is active up to the next move command.

The error signal
1)

(releasing before ready) can be reset by deactivation the drive.

Hint: With the assembly of the option module SBT you kindly note the extended functions of the
signals (see documentation 07-02-10-02-E..)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

69

9
9.3

Diagnosis and Trouble-Shooting
Trouble shooting

The following list refers to faults which can occur during operation.
Display:

Error

Explanation and remedy

no motor run despite current flow

motor mechanically blocked?
motor brake released?
check setpoint wiring
check grounding and shielding
too high P-amplification in the speed controller
reduce value
(with EASYRIDER® setting/speed control)
too small I-time in the speed controller?
reduce value
(with EASYRIDER® setting/speed control)
Limit switch functions
effective (BIAS)
motor cables interrupted?
Is input "I extern" (X10.19) activated
(config. menu) and not notched up?

motor runs unevently

no reaction of setpoint progression, despite
torque in standstill
no current flow;
no torque despite activating the regulator
correctly

1)

limit switch - input
activated and not notched up?
Interference symptoms with power
Ground loops in setpoint or actual value wiring?
frequency
Shieldings laid on both sides?
Signal cables near high voltage cables?
Motor takes up preferred positions after
Position encoder or motor cables with reversed
activation
poles?
Resolver or Feedback- encoder incorrectly
adjusted?
Number of motor poles wrong matching? (config.
menu)
Motor runs up immediately after activation
Motor cables or feedback- cables reversed?
although there is no setpoint
Encoder incorrectly adjusted?
(e.g. Resolver)
Motor reaches in idling cycle very different
Feedback-Encoder incorrectly adjusted
speed when running to the right or to the left (e.g. Resolver)
1) Display

or

1)

1)

mostly short after activating; before warning

________________________________________________________________________________________________________________________________________________________________________________________________________________________

70

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Block Circuit Diagram
10

10

Block circuit diagram

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

71

11
11

General Technical Data
General Technical Data

11.1 Power circuit
galvanic separation from control circuit
specification in accordance with
short circuit and to frame proof for
overvoltage monitoring D6R..-3

in acc. with EN 50178 / VDE 0160
UL 508C and cUL
Min. 2000 releasings

overvoltage monitoring D6R..-7

Max. 765V DC ±10V DC
min. 15V DC; configurable
95 ° C +/- 5%
4,75 kHz
9,5 kHz

Max. 400V DC ±5V DC

undervoltage monitoring
overtemperature switch off at
clock frequency
frequency of current ripple

11.2 Control circuit
galvanic separation from power circuit
further information:

in acc. with EN 50178 / VDE 0160
see concept of insulation chapter 1.3.1
see data compact units chapter. 1.3.3
see data plug-in modules chapter 1.3.4

11.3 Signal inputs and outputs, connection X10
additional galvanic separation from power and
control circuit
nominal voltage of the in- and outputs
number of outputs
signal outputs via OPTO coupler
signal outputs via RELAY
contact protection with inductive load
number of inputs
signal outputs via OPTO coupler

Shortest time of signal at all input to accept the
signal in an application:

24 V DC
5
Umax = 45V DC;
I = 0..60 mA; short circuit proof, resistive load
Umax = 45V DC;
I = 1uA...1,2A
internal varistor
8
L = 0...7 V DC or open
H = 15...30 V DC
Iin 24VDC: 8 mA

Damping of the transfer from
low to high (0-->24V):

> 1 ms
fast input:
20µs (X10.4, X10.25)

Interrupt response time for fast input
Damping of the transfer from
high to low (24-->0V)

10µs (X10.4, X10.25)
fast input:
250µs (X10.4, X10.25)

Damping of the transfer
from
low to high (0-->24V):
Damping of the transfer
from
high to low (24-->0V)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

72

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Technical Data

11

11.4 Signal inputs and outputs, connection X120B resp. 120C
additional galvanic separation from power and
control circuit
nominal voltage of the in- and outputs
number of outputs
signal outputs via OPTO coupler

24 V DC +20% / -10%
4
resistive load Imax. = 2A
inductive loadmax. 1Henry
Iout.
Iout.
1A
1A
1A
1A
0,33A
0,33A
0,2A
0,2A

Iout.
1A
1A
0,33A
0,2A

short-circuit current limited by (5A)
over-temperature protection,
active overvoltage clamping (50V);
keyed
number of inputs
signal outputs via OPTO coupler

Shortest time of signal at all input to accept the
signal in an application:
Damping of the transfer from
low to high (0-->24V):
Damping of the transfer from
high to low (24-->0V)

4
L = 0...7 V DC or open
H = 15...30 V DC
Iin at 24VDC: 8 mA
> 1 ms
default input:
200µs
default input:
1000µs

11.5 Digital control
current control
Loop-Cycle-Time
settings
current limits, Adjustment by:

speed control
Loop-Cycle-Time
settings
differential setpoint input analog
resolution (including sign)

105 µs
according to factory specifications or motor data
speed control -menue
Analog Input
0..10V = 0..100%; can be normed, 10Bit

digital setpoint input

105 µs
speed control menue
Usoll = 10 V, can be normed; Ri = 10k
14 bit
via interfaces

position control
Loop-Cycle-Time

105 µs

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

73

11

General Technical Data

11.6 Digitale communication
RS232 - service interface

COM1
19200 baud, 8 databits, 1 startbit, 1 stopbit,
parity: even

Optional
RS232 / RS422 / RS 485
on SUB D – socket
CAN1, Profibus DP, SUCOnet K
on SUB D – socket
Interbus S on SUB D – socket (OUT)
Interbus S (Remote IN)
CAN2

COM2

additional on SUB D – socket

11.7 Resolver evaluation/transmitter principle
General:
The specified data refer to the combination of the standard resolver interface with Function-Module
X300_RD2; operated with the SSD Drives resolver R 21-T05, R15-T05
carrier frequency
ripple of the speed actual value signal
max. position resolution for one revolution
absolute position accuracy
relative position accuracy
1)

ft = 4,75 kHz
2% 1)
65536 / 16 bit
+/- 0,7 ° 1)
+/- 0,08 ° 1)

Data under check, Reality: Quality improved

11.8 Controllersystem
system run-up time after switching on
the control voltage
data memory / organization

max. 6 sec.
Flash Eprom 256 KB
RAM 64 KB;
EEPROM 96 kByte

________________________________________________________________________________________________________________________________________________________________________________________________________________________

74

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

General Technical Data

11

11.9 Analog-Outps
measuring pin X10.17
signal range
resolution
internal resistance

-10V.....0.....+10V
magnifier function can be normed
10 bit, independend of norming
1,8 kOhm

measuring pin X10.6
signal range
resolution
internal resistance

-10V.....0.....+10V
magnifier function can be normed
8 bit, independend of norming
1,8 kOhm

11.10 Thermal data
thermal data

see chapter 1.3

11.11 Mechanical data
dimensions
weight

see chapter 1.4
see chapter 1.3

Further data you will find in chapter 1.3

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

75

12

Disposal

12
Disposal
The digital servo drive consists of different materials.
The following table shows, which materials can be recycled and which have to be disposed
of in a special way.
material
Metal
plastics material
printed board assembly

recycle

disposal

yes
yes
no

no
no
yes

Dispose of the appropriate materials in accordance with the valid environmental control laws.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

76

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Software
13

13

Software

13.1 EASYRIDER® Windows - Software
EASYRIDER® Windows - Software is an comfortable tool to use all drive functions.
Detailed Online-Help-information’s and instruction are available.

EASYRIDER® Instructions: (extract)
Autopilote-function as interactive tutorial
System identification
BIAS - instruction-set editor
Oszilloscope-function
start-up and comissioning-tools
Setting of parameters, Setting of configurations
Servo-diagnostics, Interface diagnostics, Fieldbus diagnostics
Motor library
save system data in file, load system data from file
send system data to servo drive, save system data in servo drive
load system data from servo drive
Important:
Edited data in EASYRIDER® are transmitted to the RAM of the servo drive and active after use of the
instruction SEND. Only the instruction SAVE in EEPROM writes data into a not volatile memory. Data
are stored there power-fail save.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

77

13

Software

13.2 SSD Drives programming language BIAS
In Operating mode 5 – Position control with BIAS, three user-defined programs can be executed parallel.
The BIAS-program and the PLC-program
(sequence cascades, 1 command per position controller sampling = 844 µs) as well as the Mathematics
program (cyclic execution in remaining time of processor).
The BIAS-program is primary intended for administration of travel commands. If application permits, also
simple calculations can be performed and analog/digital I/O‘s can be serviced in this task.
The PLC-task is conceived to perform I/O logic, sequence control, monitoring and CAN-Bus
communication.
The Mathematics program is designed for complex calculations, e.g. computing of a cam, executed by the
BIAS-program afterwards. But it is also possible to store the same tasks here, as basically defined for PLCtask, which can increase PLC performance of the 637+ controller approx. twenty times.
While the BIAS-program will be executed from the start block directly after activation of
operating mode 5, the PLC-program will be first started by BIAS-command "PLC-program" and the
Mathematics program by command "Mathematics program". At reaching the command "End of program"
(Mode = 0) the respective execution pointer re-jumps to his start label.
Within the command set the following command groups are provided:
Pogram flow control
- Fixing start/end of main- and sub-programs
- Conditional and unconditional jump commands
Travel relevant commands
-Positioning commands
-Parameter commands
-Technology functions

>Register positioning
>PID-control
>Synchronous applications

Logic commands
- Logic commands for coils and internal relays
Variable commands
-Writing and reading of parameters
-Fundamental operations of arithmetic with long integer
-Type-conversions long integer <=> double float (Math.task only)
-Fundamental operations of arithmetic with double float (Math.task only)
-SIN(x),COS(x),SQRT(x) with double float (Math.task only)
-Writing and reading of synchronous profile tables.
CAN-Bus commands
-Communication with other SSD Drives products

________________________________________________________________________________________________________________________________________________________________________________________________________________________

78

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Software

13

SSD Drives programming language BIAS
The user has the possibility to program his sequence himself from this set of commands.
Available program area
Set number
0000 ...
|
...
| can be selected via
...
| data inputs X10.xx
...
| max. to block no. 63 and
...
| and Strobe X10.2
...
|
0063 ...
...
1499 last block
The BIAS operation set is listed on the next page.
You can read the exact function of the individual commands in the help function of the EASYRIDER®
Windows -Software in the BIAS editor or in the BIAS command description (10-06-05-E-Vxxxx).

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

79

13

Software

13.3 BIAS – Commands
Position = const.

[Variable X] = position
This command is only permitted
in the BIAS, PLC and MATHTask

This command is only permitted
in the BIAS- task

0

1

2

3

[Variable X] =flag Y
This command is only permitted
in the BIAS and PLC -Task

BIAS-execution pointer
This command is only permitted
in the PLC and MATH-Task

4

5

Profile value = [variable X]
This command is only permitted
in the MATH-Task

6

7

Save table
This command is only permitted
in the MATH-Task

8

PLC-program
This command is only permitted in
the BIAS and MATH-Task

9

A

B

0

Move position

Move position +
parameter

Position = const.

Position =
[variable X]

[Variable X] =
position

NOP

Flag X = const.

If input X ? const.

[Variable X] = const.

Mathematic program

Table
[[variable X]] = const.

[D_Variable X] = [D_Variable
Y]+
[D_Variable Z]

1

Move
incremental
position

Move
incremental
position +
parameter

Speed = const.

Speed =
[variable X]

[Variable X] =
speed

End of program

If flag X ? const.

If output X ? const.

If [variable X] ?
const.

Profile initialization =
const.

Table
[[variable X]] =
[Y_Variable Z]

[D_Variable X] =
[D_Variable Y] [D_Variable Z]

2

Move datum

Move datum +
parameter

Acceleration = const.

Acceleration =
[Variable X]

[Variable X] =
acceleration

Sub- program

Flag X =
flag Y

Output X = const.

[Variable X] =
[variable Y] + const.

Profile cycle length =
[variable X]

[X_Variable Y]= Table
[[variable Z]]

3

Move infinite
positive

Deceleration = const.

Deceleration =
[variable X]

[Variable X] =
deceleration

End of Sub-program

Flag X =
input Y

Output X =
flag Y

[Variable X] =
[variable Y] – const.

[Variable X] =
profile value

[ W_Variable X] =
[ Y_Variable Z]

4

Move infinite
negative

Gear factor = const.

Gear factor =
[Variable X]

[Variable X] =
gear factor

PLC-program

Flag X =
output Y

_____________

[Variable X] =
[variable Y] * const.

Profile value = [variable
X]

[ X_ Variable Y] =
const.

If [D_Variable X] ?
[D_Variable Y]

5

Move
synchron

Move synchron
+ parameter

"Position reached"
window = const.

“Position reached“
window =[variable X]

[Variable X] =
block number

Jump const.

Flag X =
flag Y & flag Z

_____________

[Variable X] =
[variable Y] / const.

_____________

[Variable [X]] =
const.

[D_Variable X] =
SIN {[D_Variable Y]}

6

Move CAM
profile

Move analogue
value +
integrator

Remaining position =
const.

Remaining position
= [variable X]

[Variable X] =
actual position Y

Jump [variable X]

Flag X =
flag Y | flag Z

_____________

[Variable X] =
flag Y

_____________

[Variable [X]] =
[variable Y]

[D_Variable X] =
COS {[D_Variable Y]}

7

Synchronous
settings 1

Move speed +
integrator

Ramp filter = const.,
[variable X]

Maximal current =
[variable X]

[Variable X] =
analogue input Y

BIAS-Execution
pointer = const.

Flag X =
flag Y ^ flag Z

_____________

[Variable X] =
[variable Y].bit Z
number

Save table

[Variable [X]] =
[variable Y]

[D_Variable X] =
SQRT {[D_Variable Y]}

8

Synchronous
settings 2

_____________

Actual position X =
const.

Actual position X =
[variable Y]

[Variable X] =
latch position Y

Wait for
”position reached”

Flag X =
! flag Y

IBT- mask number =
const.

[Variable X] =
[variable Y]

_____________

9

Move PID;
speed

_____________

If actual position X
? const.

Analogue output X
= [variable Y]

[Variable X] =
actual speed Y

Wait time = const.

Flag X = status Y

IBT- notification
number = const.

If [variable X] ?
[variable Y]

_____________

A

Move PID;
torque

Cycle length =
const.

If actual position X
? [variable Y]

PID scaling

[Variable X] =
latch status Y

Wait time =
[variable X]

If status X ? const.

CAN Command =
[variable X]

B

Set point
[axis no.] =
const.

Cycle length =
[variable X]

Sensor window =
const.

Sensor window =
[variable X]

[Variable X] =
position Y;
axis no.

BIAS-execution
pointer = [variable X]

Modus X = const.

IBT- data transfer

C

Set point
[axis no.] =
[variable X ]

Load parameter
set X =
[variable[Y]]

Sensor position =
const.

Sensor position =
[Variable X]

[Variable X] =
value Y

Jump [Var.[X]]; length
= const.; from

Flag X =
[variable Y]

CAN2 Command =
[variable X]

D

Move relative

_____________

Execute X commands

[Variable X]. bit[Y] =
const.

_____________

Start axis

_____________

Sensor
adjustment 1 =
[variable X]
Sensor
adjustment 2 =
[variable X]

[Variable X] =
axis status,
axis no. Y

E

Sensor
adjustment 1 =
const.
Sensor
adjustment 2 =
const.

_____________

_____________

If [Var. X]. bit Y ==
const. then jump

_____________

F

Stop axis

Stop axis
+
parameter

Update parameter

PID parameter

_____________

Virtual program

Axis state, axis no. X,
bit Y = const., [flag Z]

_____________

Move infinite
positive +
parameter
Move infinite
negative +
parameter

Command group “Move commands“
Command group “Parameter commands“
Command group “Variable commands“
Command group “Flag commands“
Command group “Conditional jump commands“

Command group “Program control commands“
Command group “Mathematic commands“
Command group “Output commands“
Command group “CAN- Commands“
Command group “637f commands“

________________________________________________________________________________________________________________________________________________________________________________________________________________________

80

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

[Variable X]=
[variable Y] + [variable
Z]
[Variable X]=
[variable Y] - [variable
Z]
[Variable X]=
[variable Y] * [variable
Z]
[Variable X]=
[variable Y] / [variable
Z]

[Variable X] =
[variable Y] ?
[variable Z]
[Variable X] =
[variable Y] ?
const.

[D_Variable X] =
[D_Variable Y] *
[D_Variable Z]
[D_Variable X] =
[D_Variable Y] /
[D_Variable Z]

_____________

_____________

_____________

_____________

_____________

______________

____________

_____________

_____________

_____________

_____________

_____________

_____________

_____________

[Teachvariable X] =
[variable Y]

_____________

_____________

_____________

[Variable X] =
[teachvariable Y]

_____________

_____________

_____________

Certificates
14

14

Certificates

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

81

14

Certificates

________________________________________________________________________________________________________________________________________________________________________________________________________________________

82

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Certificates

14

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

83

14

Certificates

________________________________________________________________________________________________________________________________________________________________________________________________________________________

84

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Certificates

14

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

85

15
15

Index
Index

7

E

7-segment display.............................................65, 66, 67, 68

EASYRIDER Instructions..................................................77
EASYRIDER® Windows - Software..................................77
election of the brake resistor ........................................55, 56
Electrical Installation .........................................................51
Electromagnetic compatibility (EMC) ...............................57
EMC Clip ...........................................................................22
Example for mounting........................................................59
example of an order.........................................................13

A
Achieveable specifications and conditions.........................59
Allgemein technische Daten...............................................72
Analog setpoint ..................................................................57
Analog-Outps .....................................................................75
Änderungsliste....................................................................88

F
B
BIAS – Commands ...........................................................80
BIAS commands ................................................................78
Block circuit diagram .........................................................71
Brake control and PTC evaluation .....................................45
Brake resistor .....................................................................54

Feedback Sensor Connection X30......................................30
Feedback-Sensor ................................................................29
Fieldbus interface COM2 ...................................................36
Function diagrams from inputs and outputs .......................49
Fuses, contactors, filters .....................................................52

G
C
CAN-BUS2 interface .........................................................36
Certificates .................................................81, 82, 83, 84, 85
Combination possibilities for the various communications /
I/O - modules .................................................................14
Commissioning...................................................................61
Commissioning in steps......................................................62
Compact Units 637f/K D6R ...............................................17
Compatibility with 637+ Servo Drives..............................12
Compatibility with 637 Servo Drives.................................12
Configurable pin-functions.................................................48
Configuration of the brake resistor.....................................55
Connector assignment X280...............................................45
Connector assignment X290...............................................44
Control cabinet - mounting.................................................50
Control cabling...................................................................57
Control circuit ....................................................................72
Control Signal Plug X10 ....................................................26
Control Signal Plug X10 ....................................................27
Control Signal Plug X10 ....................................................28
Controllersystem ................................................................74
Cooling...............................................................................50
Correction of supply current...............................................53

General Data.......................................................................16
General Information ...........................................................10
General view of connections ........................................23, 24
Ground connections............................................................51
Grounding, safety grounding..............................................51

H
H15 multiple pin strip ........................................................25
Hints for mounting .............................................................58
HIPERFACE® - Module X300_HF2...............................30

I
Incremental output..............................................................32
Incremental-Input ...............................................................32
Installation of the rack........................................................57
Insulation concept ..............................................................16
interface COM1..................................................................35

J
Jumper ................................................................................60

D
Danger areas.......................................................................51
Description X40 .................................................................31
Diagnose und Fehlersuche..................................................65
Digital Communication ......................................................11
Digital control ....................................................................73
Digitale communication .....................................................74
DIL – switch position .........................................................43
DIL – switch position bus termination ...............................43
DIL – switch position for module RP2CA and RP 2C8 .....43
Dimensions for Compact Device and Plug-In Module.......21
Disposal..............................................................................76

L
Layout of Power Board ......................................................15

M
measuring pin X10.17 ........................................................75
measuring pin X10.6 ..........................................................75
Mechanical data .................................................................75
Mechanical Installation ......................................................50
Modle code.........................................................................13
Modul – Designs ................................................................37
module slots .......................................................................15
module X300......................................................................29
Mounting ............................................................................50

________________________________________________________________________________________________________________________________________________________________________________________________________________________

86

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

Index

15

O

S

Operating modes................................................................ 46
Operating modes and pin functions ................................... 47
Operation configurations ................................................... 11
Option module RP SBT..................................................... 44
Option module RP SBT..................................................... 45
Output power..................................................................... 20

Safe Stop ........................................................................... 44
Safety ................................................................................ 51
Safety Precautions ............................................................... 9
Safety rules........................................................................ 57
Selection of the brake resistor ........................................... 54
Sicherheitshinweise ......................................................... 4, 8
Signal inputs and outputs..............................................72, 73
Single- and Three-Phase Supply ....................................... 19
Single-phase supply........................................................... 19
Sinus / Cosinus - Module X300_SC2................................ 30
Software ............................................................................ 77
SSD Drives programming language BIAS ........................ 79
SSI-Encoder Interface ....................................................... 34
Stepper motor input ........................................................... 33
Stepper motor input ........................................................... 33
System Description............................................................ 10
System variants ................................................................. 10

P
Pin Assignment for CAN/DeviceNet................................. 38
Pin assignment for I/O interface.............................40, 41, 42
Pin assignment for Interbus S............................................ 39
Pin assignment for Interbus S............................................ 88
Pin assignment for Profibus DP......................................... 38
Pin assignment for RS232 ................................................. 37
Pin assignment for RS422/485 .......................................... 37
Pin assignment for SUCOnet K......................................... 38
Plug-In Modules 637f/D6R ............................................... 18
Power cabling .................................................................... 57
Power circuit ..................................................................... 72
Preparation ........................................................................ 61

R
Range data ......................................................................... 16
Remote IN (COM3 B) ....................................................... 39
Remote OUT (COM2)....................................................... 39
Reset of a regulator trouble ............................................... 69
Resolver evaluation ........................................................... 74
Resolver Module X300_RD2 ............................................ 30
RS232 ................................................................................ 35

T
The Most Important Thing First .......................................... 7
Thermal data...................................................................... 75
Three-phase-supply ........................................................... 19
Trouble shooting ............................................................... 70

W
Wiring instructions ............................................................ 57

X
X120B ............................................................................... 42
X120C ............................................................................... 42
X200.................................................................................. 41

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

87

16
16

Modification Record
Modification Record

Version

Modification

Chapter

Date

Name

Comment

V0103
V0204

text correction
new functions
connection X30
additional In-/Outputs
Pin assignment for
Interbus S
correction
safety module SBT
Text addition for SBT

1.2
2.1-2.1.1
2.4.2
2.6.2.1
2.6.2.9

02.06.03

N. Dreilich

new

7-segment display
new BIAS commands
SSD Drives
diverse correction
(text, design and photos)
Model code, extended

9.1-9.2
13.3
-

V03004
V0405
V0505

photo
page 29-30
correction
text addition
“COM3 B“
page 36
page 46-47
page 12-13/25-27/
44-45/50-51/65-66
/72
new options

2.5.5
2.7

all

16.03.04
19.10.2004

N. Dreilich
N.Dreilich

12.05.2005
18.05.2005

N. Dreilich
N. Dreilich

Logos

________________________________________________________________________________________________________________________________________________________________________________________________________________________

88

Product Manual Type: 637f

07-02-10-01-E-V0505.doc

AUSTRALIA
Eurotherm Pty Ltd
Unit 1
20-22 Foundry Road
Seven Hills
New South Wales 2147
Tel: +61 2 9838 0099
Fax: +61 2 9838 9288

CANADA
SSD Drives Inc
880 Laurentian Drive
Burlington
Ontario
Canada, L7N 3V6
Tel: +1 905 333-7787
Fax: +1 905 632-0107

CHINA
Eurotherm Pty Ltd
Apt. 1805, 8 Building Hua Wei Li
Chao Yang District,
Beijing 100021
Tel: +86 10 87785520
Fax: +86 10 87790272

DENEMARK
SSD Drives
Enghavevej 11
DK-7100 Vejle
Tel: +45 70 201311
Fax: +45 70 201312

FRANCE
SSD Drives SAS
15 Avenue de Norvège
Villebon sur Yvette
91953 Courtaboeuf Cedex / Paris
Tel: +33 1 69 185151
Fax: +33 1 69 185159

GERMANY
SSD DRIVES GmbH
Von-Humboldt-Straße 10
64646 Heppenheim
Tel: +49 6252 7982-00
Fax: +49 6252 7982-05

HONG KONG
Eurotherm Ltd
Unit D
18/F Gee Chang Hong Centre
65 Wong Chuk Hang Road
Aberdeen
Tel: +852 2873 3826
Fax: +852 2870 0148

INDIA
Eurotherm DEL India Ltd
152, Developed Plots Estate
Perungudi
Chennai 600 096, India
Tel: +91 44 2496 1129
Fax: +91 44 2496 1831

IRELAND
SSD Drives
2004/4 Orchard Ave
Citywest Business Park
Naas Rd, Dublin 24
Tel: +353 1 4691800
Fax: +353 1 4691300

ITALY
SSD Drives SpA
Via Gran Sasso 9
20030 Lentate Sul Seveso
Milano
Tel: +39 0362 557308
Fax: +39 0362 557312

JAPAN
PTI Japan Ltd
7F, Yurakucho Building
10-1, Yuakucho 1-Chome
Chiyoda-ku, Tokyo 100-0006
Tel: +81 3 32132111
Fax: +81 3 32131900

KOREA
SSD Korea Co., Ltd.
1308, Daeryung Techno Town
8th Bldg., 481-11 Gasan-Dong,
Geumcheon-Gu,
Seoul 153-803
Tel: +82 2 2163 6677
Fax: +82 2 2163 8982

NETHERLANDS
Eurotherm BV
Genielaan 4
2404CH
Alphen aan den Rijn
Tel: +31 172 411 752
Fax: +31 172 417 260

Poland
OBR-USN
ul. Batorego 107
PL 87-100 Torun
Tel: +48 56 62340-21
Fax: +48 56 62344-25

Romania
Servosisteme SRL
Sibiu 17
061535 Bukarest
Tel: +40 723348999
Fax: +40 214131290

SCHWEDEN
SSD Drives AB
Montörgatan 7
S-30260 Halmstad
Tel: +46 35 177300
Fax: +46 35 108407

SPAN
Eurotherm Espana S.A.
Pol. Ind. Alcobendas
C/ La Granja, 74
28108 Madrid
Tel: +34 91 661 60 01
Fax: +34 91 661 90 93

SWITZERLAND
Indur Antriebstechnik AG
Margarethenstraße 87
CH 4008 Basel
Tel: +41 61 27929-00
Fax: +41 61 27929-10

United Kingdom
SSD Drives Ltd
New Courtwick Lane
Littlehampton
West Sussex BN17 7RZ
Tel: +44 1903 737000
Fax: +44 1903 737100

U.S.A
SSD Drives Inc.
9225 Forsyth Park Drive
Charlotte
North Carolina 28273-3884
Tel: +1 704 588 3246
Fax: +1 704 588 3249

Local availability and service support also in:
Argentina · Austria · Bangladesh · Brazil · Chile · Colombia · Costa Rica · Cyprus · Czech Republic · Ecuador · Greece · Hungary ·
Indonesia Iceland · Israel · Kuwait · Lithuania · Malaysia · Marocco · Mexico · New Zealand · Nigeria · Peru · Philippines · Portugal ·
Saudi Arabia · Singapore · Slovenia · Sri Lanka · South Africa · Taiwan · Thailand · Turkey · United Arab Emirates · Vietnam

SSD Drives GmbH
Head Office

Plant Servosystems

Von-Humboldt-Straße 10, D-64646 Heppenheim
Telefon +49 (0)6252 7982-00, Fax +49 (0)6252 7982-05

www.SSDdrives.com

·

Im Sand 14, D-76669 Bad Schönborn
Telefon +49 (0)7253 9404-0, Fax +49 (0)7253 9404-99

ssd@ssddrives.de



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 89
Page Mode                       : UseOutlines
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:65aa28c2-f914-4742-8112-ed1961e493ff
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Company                         : SSD Drives GmbH
Create Date                     : 2005:08:18 10:43:20+02:00
Creator Tool                    : Acrobat PDFMaker 6.0 für Word
Modify Date                     : 2005:08:18 11:00:41+02:00
Metadata Date                   : 2005:08:18 11:00:41+02:00
Document ID                     : uuid:1f38e25a-7ce1-4c00-8214-3e07fd018618
Format                          : application/pdf
Title                           : Servo drive 637f
Creator                         : Norbert Dreilich
Author                          : Norbert Dreilich
EXIF Metadata provided by EXIF.tools

Navigation menu